<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://www.na-mic.org/w/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=Azaitsev</id>
	<title>NAMIC Wiki - User contributions [en]</title>
	<link rel="self" type="application/atom+xml" href="https://www.na-mic.org/w/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=Azaitsev"/>
	<link rel="alternate" type="text/html" href="https://www.na-mic.org/wiki/Special:Contributions/Azaitsev"/>
	<updated>2026-04-06T09:03:40Z</updated>
	<subtitle>User contributions</subtitle>
	<generator>MediaWiki 1.33.0</generator>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=71096</id>
		<title>Projects:ARRA:SlicerWF</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=71096"/>
		<updated>2011-09-27T16:41:08Z</updated>

		<summary type="html">&lt;p&gt;Azaitsev: /* Annual Progress Statements */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Projects:ARRASuplements|Back to Slicer ARRA home page]]&lt;br /&gt;
= Aim =&lt;br /&gt;
Supplement 3D Slicer and Extensible Neuroimaging Archive Toolkit (XNAT) with workflow management system. Provide integration and interoperability between 3D Slicer, XNAT Services and 3-rd party image processing applications and high performance computing systems. Implement it as within currently developed Structural Planning and Implementation in Neurological Exploration (SPINE) System.&lt;br /&gt;
&lt;br /&gt;
= SPINE Project Documentation =&lt;br /&gt;
[http://cni.bwh.harvard.edu/projects/spine/index.html SPINE Docs]&lt;br /&gt;
&lt;br /&gt;
= Presentations =&lt;br /&gt;
* Segmentation Workflow. PECS University Social Cognition Study.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:SlicerWF_NAC_PECS_Workflow.pdf]]&lt;br /&gt;
* EAB10_ARRA Annual Progress Report Slides.&amp;lt;br&amp;gt;&lt;br /&gt;
[[media:EAB10_ARRA_WF_2011_Zaitsev.ppt | Service Oriented Solutions for 3D Slicer. EAB10_ARRA_WF_2011. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:EAB10_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:NAMIC_ARRA_WF_2011_Zaitsev.ppt  | NAMIC Annual Report 04/2010-03/2011. NAMIC_ARRA_WF_2011_Zaitsev. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:NAMIC_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:Slicer_WF_Slicer4CARMAWorkflow.ppt  | CARMA Workflow. Cardiac Ablation Followup. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:Slicer_WF_Slicer4CARMAWorkflow.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* CARMA Project Beta release Demo Location: http://cni29.bwh.harvard.edu/SlicerWFDemo/index.php&lt;br /&gt;
&lt;br /&gt;
* Segmentation Workflows: Screenshots, scans' and study description : [[File:SlicerWF_EMSegmentProjectsReview.zip]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
= All Hands Meeting Pages =&lt;br /&gt;
* MIT 2011 Summer:&lt;br /&gt;
 Workflows Project [http://www.na-mic.org/Wiki/index.php/Summer_project_week_2011_Workflows_SOA MIT_2011_WorkFlow]&lt;br /&gt;
 Segmentation Project (MS Lesions)[http://www.na-mic.org/Wiki/index.php/2011_Summer_Project_Week_Customizing_EMSegmenter_pipelines_for_brain_lesions MIT_2011_LesionsSegmentation]&lt;br /&gt;
* Salt Lake City 2011 Winter [http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA SLC_2011_WorkFlow]&lt;br /&gt;
* MIT 2010 Summer [http://wiki.na-mic.org/Wiki/index.php/Summer_project_week_2010_Workflows_SOA MIT_2010_WorkFlow]&lt;br /&gt;
&lt;br /&gt;
= Research Plan =&lt;br /&gt;
*Create a stand-alone SPINE desktop agent with fully functional data exchange and communication mechanisms towards 3D Slicer and XNAT.&lt;br /&gt;
*Develop Service Oriented Architecture (SOA) SPINE System that will include 3D Slicer image processing modules deployed as web services as well as a workflow management system to orchestrate interaction between 3D Slicer, XNAT, and 3-rd party tools.&lt;br /&gt;
*Implement two-way control and communications between 3D Slicer and SPINE modules.&lt;br /&gt;
*Adapt SPINE System for cluster and grid computing scenarios.&lt;br /&gt;
*Provide with workflow and 3D Slicer web service wrappers editing tools.&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:UseCaseScenarios| Use Case scenarios]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PETCTWorkflow| PETCTWorkflow]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:AgingStudySegmentation| AgingStudySegmentation]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:TwoTensorTractography| TwoTensorTractography]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:LongitudinalMultimodalityRegistrationSuite| LongitudinalMultimodalityRegistrationSuite]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:MigrationJavaClients2QT| MigrationJavaClients2QT]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PediatricMSSegmentation| PediatricMSSegmentation]]&lt;br /&gt;
*[[DBP3:Utah:RegSegPipeline| MRI-based study and treatment of atrial fibrillation]]&lt;br /&gt;
&lt;br /&gt;
= Application Server / Workflow Engine Downloads =&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:WFEngineDownloads| Download Links]]&lt;br /&gt;
&lt;br /&gt;
=Key Personnel=&lt;br /&gt;
* Charles Gutmann, MD., 4%,  9-17-2009 through 9-16-2011&lt;br /&gt;
* Alexander Zaitsev, Ph.D., 75%, 9-17-2009 through 9-16-2011 &lt;br /&gt;
&lt;br /&gt;
=Annual Progress Statements =&lt;br /&gt;
'''2010-11''' &amp;lt;br&amp;gt;&lt;br /&gt;
The  April 2010 – March 2011 period was devoted on developing portable workflow solutions that can be deployed on end-users' workstations or notebooks with minimal or no system administration activities. This is in contrast to the server-side deployment. The following scenarios had been deployed and used for actual projects that require the following types of workflows: PET/CT registration and computation of biomarker driven brain physiological activities, Brain MRI Images segmentation,  MRI and MRI Angiography images pre-processing for cardiac ablation outcome estimation. Some  workflows (like EM Segmentation) had been utilizing various scenarios, some research projects  (like evaluation of chemotherapy outcome) require two types of workflows to assess physiological and structural changes. Starting from the 4th Quarter of 2011, the migration project had been emerged in order to embed Workflow GUIs into newly developed Slicer4 Suite. The existing rich client Java GUI applications are being re-written as C++/QT Sliceletts units, new modules (such as cardiac ablation project support) are had been written from scratch. The latter are being deployed from the Slicer4 GUI and act at a liaison between Slicer4 and Application Server containing  workflow and Slicer modules deployed as services. The feedback from the end users indicates that Workflow approach for the complex processing improves productivity, aids to the processing standardization and contributes to the overall experience using 3D Slicer&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* '''3d Qtr, 2011''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study: Follow-up with end-users. &lt;br /&gt;
*** End-users started a new study. The multi-study configuration support is confirmed&lt;br /&gt;
*** Debugging and workarounds of minor issues addressed&lt;br /&gt;
&lt;br /&gt;
** Left Atrium Ablation Assessment (CARMA Project)&lt;br /&gt;
*** Work on the custom build and packaging of the Slicer4 with CARMA workflow included (90% completion - pending Slicer4/QT compilation framework issues resolution)&lt;br /&gt;
*** Presentation and demo outside of NA-MIC community: Moscow Cardiological Center. Slicer4 is under evaluation, checking feasibility of 3T cardioMRIs segmentation&lt;br /&gt;
&lt;br /&gt;
** Multiple Sclerosis CLIMB Study&lt;br /&gt;
*** Reprocessing for lesion segmentation&lt;br /&gt;
*** Developed Web-based (Java EE 6) application for submitting cases to the workflows for EM Segmentation of MPRAGE and registration to PD/T2/FLAIR images. Deployed at end-users site, currently used for segmenting the cases that could not be segmented with in-house (Non-Slicer) algorithms.&lt;br /&gt;
&lt;br /&gt;
** EM Segmentation: &lt;br /&gt;
*** Embedded into the Web-based image processing suite (see CLIMB study above)&lt;br /&gt;
 &lt;br /&gt;
** User and developer documentation&lt;br /&gt;
*** Documenting steps for integrating 3D Slicer modules with OpenESB workflow engine&lt;br /&gt;
&lt;br /&gt;
* '''2d Qtr, 2011''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study: Second release deployed. &lt;br /&gt;
*** End-users completed the first Project and currently analyzing SUV values and clinical data&lt;br /&gt;
*** New features added: Human Brain Hemispheres segmentation, Scull-stripping for total SUV counts calculation, Flexibility of custom designed label look-up table usage (users can define ROI notation according to the Project needs)&lt;br /&gt;
&lt;br /&gt;
** Left Atrium Ablation Assessment (CARMA Project)&lt;br /&gt;
*** Completed workflow pipeline for automated pre-processing and manual intervention&lt;br /&gt;
*** Developed front-end GUI for the CARMA Project support in Slicer4.&lt;br /&gt;
*** Run the workflow with the end users during NAMIC Project Week&lt;br /&gt;
*** Evaluated feasibility of left atrium wall and post-ablation scar segmentation using Robust Statistical Segmentation (RSS). Identified necessary processing controls with RSS module designers&lt;br /&gt;
&lt;br /&gt;
** Multiple Sclerosis CLIMB Study&lt;br /&gt;
*** Reprocessing for lesion segmentation&lt;br /&gt;
*** Developed Web-based (Java EE 6) application for submitting cases to the workflows for EM Segmentation of MPRAGE and registration to PD/T2/FLAIR images (60% completion)&lt;br /&gt;
&lt;br /&gt;
** EM Segmentation: &lt;br /&gt;
*** Upgraded EM Segmentation services to Slicer 3.6.4&lt;br /&gt;
*** Added brain hemispheres segmentation module to the workflows (used for PET/CT Longitudinal study)&lt;br /&gt;
*** Work with EM Segmenter module developers on building pipelines for white matter lesion segmentation (work in progress)&lt;br /&gt;
&lt;br /&gt;
** Plans for the 3rd quarter&lt;br /&gt;
*** Migrate CARMA Project workflow to end-users&lt;br /&gt;
*** Packaging of Slicer4 Workflow modules and Slicer4 custom build distribution &lt;br /&gt;
*** Completion of Web-base segmentation and registration suite&lt;br /&gt;
*** Users and Developers Documentation&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* NAMIC Annual Progress Slides (April 2010 - March 2011):&lt;br /&gt;
&lt;br /&gt;
* '''1st Qtr, 2011''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study: Second release is under testing by end-users. &lt;br /&gt;
*** Added MRI registration to aid ROI drawing on PET scans&lt;br /&gt;
*** Improved SUV results reporting and added flexibility to update ROI lookup table&lt;br /&gt;
*** Automated EM Segmentation of MRI images for computing SUVs for white matter, CSF, and whole brain (80% completion)&lt;br /&gt;
*** Integration with SPECTRE scull stripping module (70% completion) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** EM Segmentation: Automated WF Pipelines are created &amp;lt;br&amp;gt;&lt;br /&gt;
*** Flexible atlas selection (Pediatric, etc) feature added&lt;br /&gt;
*** Workflows implemented for EM Segmenter 3.6.2 and 3.6.3 (1st Qtr 2011 release)&lt;br /&gt;
&lt;br /&gt;
** Cardiac ablation results follow-up: Workflow for registration and ROI selection of cardiac MRI and MR Angiography &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Wrokflow and Web Services for prospective DTI tractography modules (currently written as Matlab modules at PNL) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Web Services for SPECTRE Scull stripping module&lt;br /&gt;
*** Accuracy and performance tuning&lt;br /&gt;
*** 50% completion&lt;br /&gt;
&lt;br /&gt;
** Migration Front End GUI to Slicer4/QT:&lt;br /&gt;
*** EM Segmentation&lt;br /&gt;
*** Cardiac Ablation Study&lt;br /&gt;
&lt;br /&gt;
** DICOM Uploader and Desktop Browser for XNat Image repository (alpha version - tested for MGH MS Center studies, proposed to use with MI2B2 Clients and Services)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''4th Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study and EM Segmentation for Aging Study are deployed at end-user sites and actively used for research. &lt;br /&gt;
** Adopted EM Segmentation preprocessing pipeline for HIV Study: high resolution SPGR images, integration with FreeSurfer brainmask extraction outputs; integration of Slicer SPECTRE module for brainmask extraction is in progress.&lt;br /&gt;
** The following post-release upgrades had been implemented based on end-user feedback: Application Server basic controls are performed from Rich Client GUI as alternative to traditional IT administration activities. The controls are implemented on point-and-click bases and include web services and workflow application deployment and upgrades, application server start and stop as well as warning end user when the server is not accepting request.&lt;br /&gt;
** Added DICOM downloads and results uploads of PET/CT pipelines from and to XNat Repository&lt;br /&gt;
** Created Services and Workflow for Matlab Prototypes modules. Case Study: tractography for DTI images&lt;br /&gt;
** Extended XNAT integration services:&lt;br /&gt;
*** Browsing capabilities of XNat data repository from the Workflow Applications&lt;br /&gt;
*** Improved DICOM upload and download performance&lt;br /&gt;
*** Added Metadata organizing services for uploaded DICOM images: header data extraction, image snapshots creation. &lt;br /&gt;
** Started project for Rich Client GUI migration from Java desktop application to build into SLicer4 QT modules. This affects mostly front-end GUI and has the following approaches: distribution with the Slicer4, end-user will select desired workflow application from Slicer4 menu while QT-written modules provide with the same functionality as Java Rich Clients. Case Study for the Migration process: registration suite for longitudinal studies that include multi-modality images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* '''3d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Concentrated on building downloadable workflow applications that could run both in desktop (new) and server environment, and that require minimum IT administrative resources. The desktop deployment is in compliance with Slicer3 general deployment concept.&lt;br /&gt;
*** The following use case scenario had been chosen: PET/CT image processing for longitudinal studies, EM Segmentation for longitudinal Aging Study.&lt;br /&gt;
** Released workflow application for PET/CT image processing for longitudinal studies. Provided end users with training and documentation.&lt;br /&gt;
*** The PET/CT processing workflow was designed to be a general application used whenever both structural patterns and metabolic activities are within the research scope. &lt;br /&gt;
*** The desktop version is tuned to use minimal computer resources, so the automates processing instances do not interfere with human activities. Automated activities may include, for example, registration and PET scan's standard uptake values computing, and manual human activities may include image cropping, quality control, and labeling voxels of interest.&lt;br /&gt;
** Core services and EM Segmentation preprocessing workflow was build for retrospective Aging Study. Tuned the Slicer3 webservices for processing low grade images acquired in mid 90s. Entire workflow is implemented with Slicer3 only modules and can be deployed locally and on the servers. Usage of Service Oriented Architecture (SOA) as a core technological approach allowed reusing most of the web services that had been build for PET/CT project. &lt;br /&gt;
** Continued embedding Slicer3 application and modules into previously released processing pipelines: replaced MIPAV with Slicer3 GUI for lesion assessment step in the multi-center Pediatric MS Cohort image processing &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''2d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Completed Social Cognition Workflow Implementation. This includes EM Segmetnation pre- and post-processing pipelines, data tracking, and integration with 3d party image processing utilities, as well as processing results acquired manually with Slicer GUI.  &lt;br /&gt;
** Multi-modality image registration and ROI selection/alignment workflow for longitudinal studies. &lt;br /&gt;
*** Use case: PET/CT image processing for longitudinal studies. &lt;br /&gt;
*** Build portable library of Slicer modules as web services and workflow that are deployed and run on a end-users' worksatations without utilization of SPL and other servers. The web services include novel Slicer3 modules, such as BRAINSFit and BRAINSResamle &lt;br /&gt;
*** Started working with Slicer3 developers on Slicer 3.8 GUI wizard to communicate with workflow instances.&lt;br /&gt;
** Participated at NA-MIC Summer 2010 Project Week: [[Summer_project_week_2010_Workflows_SOA]]&lt;br /&gt;
&lt;br /&gt;
=Progress=&lt;br /&gt;
* September 2, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT Project:&lt;br /&gt;
* New study follow-up&lt;br /&gt;
* Debugging SUV consolidated computation: V2.1 requires all or no MRIs for all cases. Does not work correctly when only  a subset of patients has MRIs&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* August 26, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project:&lt;br /&gt;
* Packaging on Max OS X 64-bit: troubleshooting QT 4.6 (build tree) QT 4.7 (make package) conflicts&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
3D Slicer WF. General&lt;br /&gt;
* 3D Slicer and WF Modules presentation at MGH Radiation Oncology&lt;br /&gt;
&amp;lt;br&amp;gt;  &lt;br /&gt;
&lt;br /&gt;
* August 19, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation&lt;br /&gt;
* Deployed first release (Human Brain EM Segmentation) web request application&lt;br /&gt;
* End-users requested EM Segmentation of MS lesion on PD images (feasibility is being evaluated with EM Segmenter Team)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
3D Slicer WF. General&lt;br /&gt;
* Preparation of 3D Slicer and WF Modules presentation for MGH&lt;br /&gt;
&amp;lt;br&amp;gt;  &lt;br /&gt;
&lt;br /&gt;
* August 12, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
* Migrating build to updated Slicer4 environment  (PythonQT and new added module dependencies issues)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation&lt;br /&gt;
* Tested and reviewed EM Segmentation web app on end-users' data&lt;br /&gt;
* Updated workflow, so EM Segmentation is performed on T1 after registration to T2 or FLAIR. This gives more accurate results comparing to segmentation of high resolution image followed by resampling (have to use nearest neighbor interpolation to retain actual label values) of label map &lt;br /&gt;
&lt;br /&gt;
* August 5, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT&lt;br /&gt;
* Follow-up with end users with new Study setup&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
CARMA Project&lt;br /&gt;
* Documentation (Work in progress)&lt;br /&gt;
* Plans for next week: custom packaging (Mac Snow Leopard 64 bit), building extension, documentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation&lt;br /&gt;
* Stress-test of online segmentation requests suite for  [http://www.slicer.org/slicerWiki/index.php/EMSegmenter-Tasks#Additional_Use_Cases CLIMB Study](for BWH MS Center)&lt;br /&gt;
* Reason for building online suite: the Group is Using mostly MAC OS Tiger machines for legacy reasnos, the most recent Slicer3 builds as well as QT don't work on those machines (QT4.x runtime could not be installed).&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* July 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA Project&lt;br /&gt;
* Documentation (Work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation&lt;br /&gt;
* Work on alpha-release of online submission of segmentation requests (for BWH MS Center)&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* July 22, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
Vacation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* July 8, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
3D Slicer in General and CARMA Project&lt;br /&gt;
* Presentation and life demo at Cardiology Research Center (Moscow, Russia) [[File:RussianCardiologyCenterCARMA2011.ppt]]&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* July 1, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA V1.0&lt;br /&gt;
* Migration to new QT building environment (Mac 10 Snow Leopard). &lt;br /&gt;
* Building custom package. Issues: new features (not only WF related) are not shown on the menu of the resulting application&lt;br /&gt;
* Comparing preprocessing workflow results with published in literature data (our module produces better alignment)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*June 24, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
Project Week:&lt;br /&gt;
* Testing RSS module for left atrial wall scar segmentation&lt;br /&gt;
* Testing EM Segmenter for lesion detection on PD (requested by end-users) and FLAIR images&lt;br /&gt;
&lt;br /&gt;
EM Segmentation &lt;br /&gt;
* Web-based segmentation and registration module for MS Center. Goal: facilitate 3D SLicer modules for the cases that could not be processed with in-house build DTS+ algorithm&lt;br /&gt;
* Pipeline: Segment MPGR or T1 (user's choice), Register MPGR to PD/T2, Resample Segmentation Map to PD/T2. Completion: 60-70%.&lt;br /&gt;
* The rest will be done manually or via lesion segmentation with EM Segmenter.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* June 17, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
Preparation for Project Week&lt;br /&gt;
&lt;br /&gt;
* June 10, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
CARMA V.1.0&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code completed and tested&lt;br /&gt;
* Packaging as extension is pending (Subject for Summer 2011 Project week)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Debugging consolidation results issue(SUVs for manual and automated segmentation) &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* June 3, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Deployed on end-user's machine&lt;br /&gt;
* TODO next week: fix SUV results consolidation issue (when MRI segmented ROI got SUV computed for some subjects, only those subjects' SUVs are being added into consolidated report. &amp;quot;Raw&amp;quot; SUV values per subject are generated as expected)  &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 27, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Ready for deployment. New Features: hemispheres EM Segmentation, automated ICC/brainmask extraction using EM Segmenter, fixed controls for MRI conversion and registration&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 20, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General / PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Hemispheres EM Segmentation - adjusted for required label lookup table&lt;br /&gt;
* Use cases added for EM Segmenter General Project: http://www.slicer.org/slicerWiki/index.php/EMSegmenter-Tasks#EMSegmenter_use_cases&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SPECTRE Scull Stripping&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* The new version to be tested on coming week (After PETCT MRI processing migrated to Hemispheres scenario )&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* May 13, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General / PETCT V1.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Hemispheres EM Segmentation - technically works with labal values hardcoded in Slicer EM Segmenter - need to add manual label value edition step&lt;br /&gt;
* PETCT WF Cut for Java GUI (Pending Hemispheres label update completion). Next release will be in QT4.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* May 6, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (QA of EM Segmenter module, work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* April 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Open Discussion for Packaging WF QT Modules as Slicer4 extensions (waiting for SOPs)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review supported projects http://wiki.na-mic.org/Wiki/index.php/File:SlicerWF_EMSegmentProjectsReview.zip &lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (required by Study)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Slicer Modules General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Standardizing Crop Volumes Output (with A. Fedorov's module). Review for required updates of existing product (PET/CT, CARMA)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Open Discussion for Packaging WF QT Modules as Slicer4 extensions (waiting for SOPs)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review supported projects http://wiki.na-mic.org/Wiki/index.php/File:SlicerWF_EMSegmentProjectsReview.zip &lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (required by Study)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Slicer Modules General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Standardizing Crop Volumes Output (with A. Fedorov's module)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 22, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Beta release ready. Demo Location: http://cni29.bwh.harvard.edu/SlicerWFDemo/index.php&lt;br /&gt;
* TODO: Tutorial. Original inputs copy/renaming&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 15, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Adding App server auto-config features&lt;br /&gt;
* Finalizing the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 08, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Second release beta build tested on cosutmer side &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review registration quality (with Dr. Meier). Angiography images' Resampling tuned. &lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 01, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the second release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
XNat Integration&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* (Java) GUI for Project Browsing and DICOM Series Upload. Post-upload DICOM processing tested and debugged&amp;lt;br&amp;gt;&lt;br /&gt;
* Ready for integration with mi2b2 client.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Migrated to Latest Slicer 3.6.3 stable release: only the Input scene had to be updated, the API remained the same&lt;br /&gt;
* Tested EM Segmenter with CMTK4Slicer extension - processing takes to much time on Linux_64bit machine, rolled back to BRAINSFit registration. When used on Mac OS X build, the Slicer could not start (bug report 1126).&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SPECTRE Scull Stripping:&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Testes for various use cases: the module is extremely sensitive to T1 MRI quality (does not work for most MRIs from PET/CT project&lt;br /&gt;
* TODO next week: check for FLAIR images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Slicer4 QT GUI and Cropping activity in progress.&amp;lt;br&amp;gt;&lt;br /&gt;
* Tried direct MRA to MRA registration option: resampling with LMRI registration transforms works better.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Extra VOI labels revised&lt;br /&gt;
* Debugging of SUV results' renormalization step&lt;br /&gt;
* TODO: ICC extraction / whole brain total uptake computing; EM Segmentation for R_WM, L_WM SUV computing and BPH estimation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SCULL STRIPPING/SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Installed and tested CLI option on Linux_64bit platform&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Workflow interruption before BSPline registraton: BPEL Module completed. Slicer4 QT GUI and Cropping activity in prorgess.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Implemented and Tested with end-users proposed changes: denormalization of SUV results, adding more VOI labels, added FLAIR MRI in addition to T1s for VOI drawing&lt;br /&gt;
* Tested manual ICC extraction using PET scans: works satisfactory with island removal and cropping followed by threshold level labeling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4&lt;br /&gt;
* Change proposed: interrupt workflow after affine registration and have user crop the VOI. This is to prevent excessive deformations for BSpline registration and resampling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4. User has option to choose the atlas that fits better for the given subject (NOTE: hardcoding must be rewritten for atlas linking)&lt;br /&gt;
* PETCT test - the problem is that T1s are low resolution and with contrast. Proposed using T1s without contrast&lt;br /&gt;
* PETCT change request: users wants to compute SUV for entire ICC. Had demo how to segment brainmask/ICC using PET scan. The derived brainmask label can be used for SUV computation.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - cmpleted&lt;br /&gt;
* Sample cases run - excessive deformation after BSpline registration hase&lt;br /&gt;
* Next week plan - pull tuning controls to front-end of pipeline API, start working of QT module for CARMA registration&lt;br /&gt;
* May consider other than BRAINSFit registration modules&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Design plan for change request: more VOI labels, add FLAIR in addition to T1 for VOI drawing, T1s segmentation&lt;br /&gt;
* Tested segmentation for sample cases - artifacts from poor quality MRIs lead to exclusion of parts of ICC from segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Completed troubleshooting of EMSegmenter module calling from Java (need TCL libs to be pulled from Slicer environment)&lt;br /&gt;
* Tested EMSegmenter autoruns for HIV and Pediatric MS patiens. Work as expected, subject to improvement of PED MS case segmentation by building better skull/neck/air atalses&lt;br /&gt;
* Suggested usage of two subsets of atalases: with and without neck. The Subject MRIs have to be cropped accordingly or best fit atlas has to be selected&lt;br /&gt;
* Made no-neck cropped atlas collection for default EMSegmenter scenario&lt;br /&gt;
* Tested with PET/CT study MRI cases - see above &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - in progress&lt;br /&gt;
* Next week goal - have back end processing ready&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Longitudinal Study&lt;br /&gt;
* Added MRI registration to the pipeline&lt;br /&gt;
* Troubleshooting of complex XML schema issues on Linux machines (some modules working on MAC do not work on Linux). As a workaround - did not include MRI convert and register part into base BPEL module. Used separate services (transparent for end-user)&lt;br /&gt;
* TODO next week for change request completion: explicit pixel type casting for MRI in BRAINSFit, VOI MRML scene update (currently MRI added on top of schema)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* February 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipeline for Pediatric MRI. Same scenario as for HIV Project, icbm pediatric atlases (Completed, verified)&lt;br /&gt;
* Collected NIH healthy brain development atlases: various age ranges from 4.5 to 18 yo. Converted to Slicer readable format &lt;br /&gt;
* Work on web services for the new automated EM Segmenter module (release Nov 10 - current). Verified task completion both for adult and pediatric images. Discussed tuning parameters for work load balance on workstations.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Started working on MRI registration to the reference CT scans. &lt;br /&gt;
* Design specs for optional White Matter segmentation for SUV computing.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* February 4, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipelines for Pediatric MRI (in progress)&lt;br /&gt;
* Adapting Pediatric T1 atlases for &amp;quot;Human Brain&amp;quot; build-in EM Segmentation wizard (in progress)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 28, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Verifying EM Segmenter module for latest builds and HIV/PED MS Studies (report pending)&lt;br /&gt;
* Work with SPECTRE module developers with pediatric MRI brainmask extraction&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* January 21, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Compiling plan for WF FrontEnd GUI migration to Slicer4/QT Widgets&lt;br /&gt;
* Preparing for annual progress report&lt;br /&gt;
&lt;br /&gt;
* January 14, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI: Integrated into the Slicer4 as Slicelet (or thin Client)&lt;br /&gt;
* Participation at AHM-2011, discussing integration of SPECTRE module and updated approach to EM-Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA&lt;br /&gt;
&lt;br /&gt;
* January 7, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* HIV project workflow delivered. Major additions relate to user convenience: &lt;br /&gt;
- Project-specific parameter settings, importing T1s and brainmasks from FreeSurfer outputs with conversion to NIFTI, resampling brainmask to original scans and automatied subject addition.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Follow up with end user: need to add MRI scans, if available, addition and registration to CT in order to ease VOI drawings.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
 &lt;br /&gt;
* December 31, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Follow-up with user Experience for AGING Study Segmentation (Positive feedback)&lt;br /&gt;
* Target date for HIV project delivery - next week&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Self-training for QT widget development&amp;lt;br&amp;gt;&lt;br /&gt;
* Outlined Workflow Rich Clients migration strategy from Java to QT/Slicer4:&amp;lt;br&amp;gt;&lt;br /&gt;
** Use Java Stubs (similar to SPECTRE integration) or file binding for envocation of workflow pipelines. (See SOAP remark below)&lt;br /&gt;
** Direct Web Servisec calls must be wrapped into REST protocol. The reason: NON-commerchial QT kit does not include SOAP protocol for web servises.&lt;br /&gt;
** The GUI will be implemented as page widget or QT dialog GUI forms called from within Slicer4.&lt;br /&gt;
** Communications between Slicer4 and WF GUI will be set via child-parent and signal-slot relations&lt;br /&gt;
* Worked on a Prototype for Basic EM Segmentation QT widget (70% complete). Will work on integrtion with SLicer4 during the AHM-2010&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
XNAT Integration&lt;br /&gt;
* Debugged XNAT RESTFul API usage for uplaoding DICOM series followed by header data extraction and image snapshots creation&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Added compensation for failed atlas registration (subject for old poor quality pseudo-T1 images): blank probability maps are created in case of failure.&lt;br /&gt;
* Data preparation module for FreeSurfer data import near completion. Expected time for deployment at end-users workstations - first week of January&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Discussed strategy for EM Segmentation pipeline solutions collection (K. Pohl, R. Kikinis)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* RE-using the same core workflow as for 1-channel EM Segmentation of AGING STUDY cases&lt;br /&gt;
* Added data input preparation module: ICC label mask preparation and skull-stripping based on FreeSurfer brainmask output volume.&lt;br /&gt;
* Two-channel EM segmentation pipeline (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE / GENERAL Development &amp;lt;br&amp;gt;&lt;br /&gt;
* Worked on plans for migrating fro rich workflow Java clients to embedded workflow windows inside the Slicer.&amp;lt;br&amp;gt;&lt;br /&gt;
The embedded workflow management clients are to be implemented with QT/PyQT toolkits&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
INTEGRATION WITH XNAT:&amp;lt;br&amp;gt;&lt;br /&gt;
* Automated DICOM series upload with triggering DICOM headers parsing at XNat site (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress. &lt;br /&gt;
- Results upload to XNat (Completed) &amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat based on user's input (Project + Subject + PET or CT session / scan) (Completed)&amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat - perfomance boosting solution for downloads found , web services services are created, relinking for the client side in progress &amp;lt;br&amp;gt;&lt;br /&gt;
- Xnat querying for subjects and automated subject addition into the workflow (In Progress) &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-segmentation module added for auto correction of segmentation results. Particularly - relabeling CSF voxels segmented as Air inside the intracranial cavity. This was requested by end-users after processing images with zero-signals in CSF voxels &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting automated dual-echo DICOM images conversion and split into two NRRD volumes&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT / EM Segmentation pipeline:&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting memory allocation issues for scull-stripping module SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
COPD Project:&amp;lt;br&amp;gt;&lt;br /&gt;
* Benchmark test for accelerated DICOM downloads from XNat (remoote XNat Central server): we can handle at least 6 cases (4 CT scans in each) per hour, which is compatible with current workload quotes on SPL cluster processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* December 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Deployed Version 1. &amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Test project chosen as a closest match to registration scenario: Pediatric MS Cases from MGH - requires periodic image preview for different &lt;br /&gt;
modalities taken from vaious time points. Label maps for VOIs resampling is also required.&lt;br /&gt;
&lt;br /&gt;
* November 26, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user. Version 1 is complete&amp;lt;br&amp;gt;&lt;br /&gt;
* Started working on integration with XNat&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on input data organizing modules&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 19, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user (70% done)&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Universal Registration Workflow for Longitudinal Studies - design specs in progress&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 12, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Minor tuning to EM Segmentation template as of users' feedback&lt;br /&gt;
* Users started using the workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed input data conversion from Genesis to Slicer native or NIFTI format. Our help may be needed in input data organizing.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Tuned application according to co-laborators (PNL) needs&amp;lt;br&amp;gt;&lt;br /&gt;
* The webservices and BPEL workflow application are tested ready to accept computation requests from PNL case tracking system &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Discussed Universal Registration Workflow for Longitudinal Studies&lt;br /&gt;
* Started the thread about possible cooperation with Children hospital's image processing pipelines and integration with Xnat &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 5, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Webservices and workflow pilot project created and deployed on Psychiatry Neuroimaging Laboratory subnet &amp;lt;br&amp;gt;&lt;br /&gt;
* The V.1.0 deployment is scheduled for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 29, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Most of functionality is completed. Some volume statistics post processing is pending&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL EM SEGMENTATION Pipeline: &amp;lt;br&amp;gt;&lt;br /&gt;
* The SPECTRE scull stripping module. Started integration into EMS workflow. Made some test runs from Slicer GUI&amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Identified as a candidate for Workflow Application&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 22, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* All back-end functionality are implemented&amp;lt;br&amp;gt;&lt;br /&gt;
* EM Segmentation scene usability is confirmed by end-user&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for next week: add Label Statistics computation for CSF/Brain/ICC &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 15, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* The latest (October) builds of Slicer 3.6.2 produced acceptable results. This was verified by the target users. The EM Segmentation will be performed on Slicer 3.6.2 or later&amp;lt;br&amp;gt;&lt;br /&gt;
* The new Web services had been created and added to the pipeline as optional processing steps: Biasfield correction (implement novel N2ITKBiasFieldCorrection module) and Volume's scalar datatype casting (as workaround for Biasfield correction module not preserving image scalar datatype - the bug is filed) &amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed the Front-End GUI design with target users. The design pattern is taken from the PETCT project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 8, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-deployment support. Tuned CT registration as of user's feedback.&lt;br /&gt;
* Adapting to the Single Slicer build: Slicer 3.6.2. Found label duplicates in the label lookup table - will ask user if it's tolerable. Waiting for the Slicer 3.6.2 build that contains all required modules. Rolling back label tag appending code for SUVs - the latest Slicer build appends the tags.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Resumed development. The priorities are set for usage of Slicer 3.6.2 - subject for EM Segmentation scene tuning. Continued coding for Scene creation for Slicer 2.8 - as a backup option for ongoing research project.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 1, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized V1.0 release based on end-user feedback: updates relate mostly to error proofing and SUV values representation&lt;br /&gt;
* Post-deployment support. Users pre-processed first set of patients &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* September 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* System deployed and tested at End Users' site.&amp;lt;br&amp;gt;Users are trained to perform all tasks required by the workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
* Got positive feedback with suggestions on Slicer Scenes' layouts improvement and PET scans' SUV (standard uptake values) results display&lt;br /&gt;
* Two distribution packages are assembled: Lunix and MAC OS versions. The difference in two packages is in specific Slicer3.6/3.7 builds - subject to Slicer Linux builds debugging.&amp;lt;br&amp;gt; As a workaround for Linux deployment - multiple Slicer builds are used to perform various tasks (registration, opening editing scenes in Slicer, SUV computing)&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for coming week - finalize V1.0 release based on end-user feedback&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Embedded SUV computations into the workflow (as system calls - will be translated into web service later)&amp;lt;br&amp;gt;&lt;br /&gt;
* Pre-release demo for end users.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Create and debug EM Segmenter scenes template for Slicer 3.6 and 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* September 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation - workflow pipeline and deployment verified&amp;lt;br&amp;gt;&lt;br /&gt;
* Tested EM Segmentation scenes within Slicer 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
* Started migration of EM Segmentation to Slicer 3.6. Discovered issues had been reported to EM Segmenter module designers &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* August 29 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation completed. Preprocessing Pipleine completed 80% (subject for input registration parameters tuning) &amp;lt;br&amp;gt;&lt;br /&gt;
* Most webservices (for registration and resampling steps) had been taken and re-used from PET/CT ROI/Longitudinal Study - showing the advantage of service-oriented software design and deployment.&lt;br /&gt;
* Continued on distribution and deployment of the service/workflow applications: on PET/CT and AGING STUDY projects.&lt;br /&gt;
&lt;br /&gt;
PEDIATRIC Multiple Sclerosis Cohort. Support of multi-center distributed processing project&amp;lt;br&amp;gt;&lt;br /&gt;
* Introduced Slicer 3.6 for the MS Lesion Assessment step performed at Mayo Clinic. Images are being transferred from image repository at BWH and automatically opened and arranged within Slicer GUI for reading.  This was replacement of Client GUI using MIPAV that stopped working on new computers at Mayo Clinic.&lt;br /&gt;
The images are being loaded via generated MRML Scenes same way as in PET/CT and AGING STUDY projects &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* August 22 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Preprocessing pipeline merge with SUV computations &amp;lt;br&amp;gt;&lt;br /&gt;
- QA for SUVs computation was performed by Wendy Plesniak for images with known uptake values. &amp;lt;br&amp;gt;&lt;br /&gt;
- Discovered that image cropping step (not related to automated registration pipeline and SUVs computing) smoothes the images by doing interpolation when used with default settings. Got suggestions from Steve Piper using Nearest-Neighbor interpolation (&amp;quot;no interpolation&amp;quot;) for a time being&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
- This is the new project candidate. Requested for the images with failed manual segmentation and/or segmentation with FreeSurfer. The EM Segmentation run showed most acceptable results on one of the problem images back in February &amp;lt;br&amp;gt;&lt;br /&gt;
- The workflow will be developed and deployed similar to PET/CT ROI Longitudinal study approach - all preprocessing steps will be done with Slicer modules, all runs will be performed on local end-user machines.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
 &lt;br /&gt;
&lt;br /&gt;
* August 15 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- First 5 cases with 3-4 time points preprocessed for SUVs computation&lt;br /&gt;
&lt;br /&gt;
* August 8 2010&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Testing of installation and operation at users' site (Performed by Wendy Plesniak)&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* July 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Delivered beta version of registration pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
- Prepared installation and user manuals &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* June 11, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Registration modules completed &amp;lt;br&amp;gt;&lt;br /&gt;
- Irregular cases registration problem solved (when whole body and brain only scans are mixed for a timepoint)&amp;lt;br&amp;gt;&lt;br /&gt;
- Live demo of case setup and registration workflow for end users. Real case with 4 timepoints used&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Coming week plans&amp;lt;br&amp;gt;&lt;br /&gt;
- Adjust workflow based on end users' feedback&amp;lt;br&amp;gt;&lt;br /&gt;
- Integration with SUVs computing for PET scans&amp;lt;br&amp;gt;&lt;br /&gt;
- GUI for workflows dispatching and data organizing&amp;lt;br&amp;gt;&lt;br /&gt;
- (TBD) Integration with 4D time series analysis Slicer module&amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
* May 28, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- Migration to the latest Slicer 3.6 release candidate &amp;lt;br&amp;gt;&lt;br /&gt;
- Added webservice for new registration module: BRAINSFit &amp;lt;br&amp;gt;&lt;br /&gt;
- Test runs for new patients with 4 timepoints' scans &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Plans for next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI &amp;lt;br&amp;gt;&lt;br /&gt;
- processing workflow demo for end user &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 21, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Pilot version of portable web services and automated workflow tested: &amp;lt;br&amp;gt;&lt;br /&gt;
Linux: workflow and visual review passed&amp;lt;br&amp;gt;&lt;br /&gt;
Stress test for 25 timepoints passed &amp;lt;br&amp;gt;&lt;br /&gt;
MAC OS: workflow passed, visual review failing when PET/CT images are loaded into GUI simultaneously (bug report submitted)&amp;lt;br&amp;gt;&lt;br /&gt;
Windows: need to adapt command line modules and workflow management system to sygwin environment&amp;lt;br&amp;gt;&lt;br /&gt;
Plans for next week: integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI&lt;br /&gt;
&lt;br /&gt;
* May 7, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Selected registration and resampling modules with more precise and stable outputs. &amp;lt;br&amp;gt;&lt;br /&gt;
Started building portable web services and automated workflow &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 30, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- manual walk through the processing steps: ROI cropping, registration/resampling, PET pharmaceutical DICOM data retention. &amp;lt;br&amp;gt;&lt;br /&gt;
- testing workflow and web services packages distribution to end-users' machines&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* April 23, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : testing various registration and re-sampling algorithms (work in progress)&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation: as of collaborators' request, run existing EM Segmentation workflow for older low resolution pseudo-T1 images. The EM Segmentation works for those images with manual sampling. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 16, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
  Social Cognition Study: started Cortical Thickness Measurement module build (bases on NA-MIC ARCTIC pipeline) &amp;lt;br&amp;gt;&lt;br /&gt;
  PET/CT ROI/Longitudinal Study Registration : Design specs, PET-to-CT images registration tests on training data. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 9, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. GUI update based on end-user experience.&amp;lt;br&amp;gt;&lt;br /&gt;
User request: automated label maps' volumes calculation (Currently possible from Slicer3 GUI)&amp;lt;br&amp;gt; &lt;br /&gt;
PET/CT ROI Project. Initial design specs discussion with end-users and co-developers&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure&lt;br /&gt;
Verification of segmentation workflow GUI: from registering new case to reviewing results&amp;lt;br&amp;gt;&lt;br /&gt;
Cross study test of segmentation workflow: MGH/MS Center data - success,  HIV Project data - some EM Segmentation scene tuning is needed &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*&lt;br /&gt;
* April 2, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. Segmentation workflow completed&amp;lt;br&amp;gt;&lt;br /&gt;
* Coming Week plans:&amp;lt;br&amp;gt;&lt;br /&gt;
- Document Segmentation Workflow. Follow up with end users &amp;lt;br&amp;gt;&lt;br /&gt;
- Start with Cortical Thickness and ROI-in-longitudinal studies workflows&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* March 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All essential processing and workflow interaction clients are ready.&amp;lt;br&amp;gt;&lt;br /&gt;
- Completed segmentation for 10 out of 50 patients. The remaining cases will be finalized upon manual lesion segmentation and QC verification of WM/GM/CSF and Deep GM segmentation's. &amp;lt;br&amp;gt;&lt;br /&gt;
- TODO next week: refine QC GUI and data tracking / progress monitoring schema. &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&amp;lt;br&amp;gt;&lt;br /&gt;
- New Slicer3 web services added: re-slicing with reference image volume, casting image scalar type &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
* March 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Segmentation maps Merging Services for GM/WM/CSF (Slicer EM Segemnter), Lesion (Slicer, Manual), and Deep GM (FreeSurfer)  &amp;lt;br&amp;gt;&lt;br /&gt;
- Deep GM segmentation pipeline adopted as optional service for Social Cognition Study (22 out of 50 cases processed) &amp;lt;br&amp;gt;&lt;br /&gt;
- (In progress) GUI client for Launching Segmentation results merging with optional Deep GM segmentation with FreeSurfer &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- Complete GUI Client for Segmentation result merging &amp;lt;br&amp;gt;&lt;br /&gt;
- Progress Monitoring services for entire Study processing: EM Segmenter Preprocessing, EM Segmentation, Lesion Segmentation (including human activities assignments), Deep GM segmentation, and results consolidation. &amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* March 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All 50 cases went through &amp;quot;basic&amp;quot; One-channel EM segmentation (GM/WM/CSF) &amp;lt;br&amp;gt;&lt;br /&gt;
- Basic pipeline start-up command line client created: user has two options - request brainmask extraction or provide with previously extracted brainmask for a given subject &amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison of GM/WN/CSF performed for Slicer EM Segmenter and FreeSurfer recon-all (used with default settings). &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmenter provides more accurate output &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmentation pipeline runs faster (40 minutes vs 12 hrs when no brainmask extraction requested) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO:&amp;lt;br&amp;gt;&lt;br /&gt;
- merging modules for automatic 1-channel EM segmentation and manual lesion segmentation &amp;lt;br&amp;gt;&lt;br /&gt;
- Emerge Cortical Thickness pipeline project: use NAC ARCTIC processing steps and modules &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Selected stable EM Segmentation scenario: White Matter, Gray Matter, and Cerebrospinal Fluid &amp;lt;br&amp;gt;&lt;br /&gt;
- First 16 cases are segmented for selected scenario. Nine more cases are preprocessed for EM Segmentation.&amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison to segmentation with FreeSurfer showed better accuracy for Slicer2 EMSegmenter &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure &amp;lt;br&amp;gt;&lt;br /&gt;
- Three prerpcocessed cases failed during volume ICC masking with in-house build utility. Evaluated switching to Slicer3 Mask and island removing modules.&amp;lt;br&amp;gt;&lt;br /&gt;
- Initial design specs discussion for cortical thickness measurement pipeline. ARCTIC pipeline selected. ARCTIC preprocessing steps signifficantly overlap with EM Segmentation preprocessing workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
  &lt;br /&gt;
* February 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: &amp;lt;br&amp;gt;&lt;br /&gt;
A) parameters tuning for EM Segmenter itself (work with EM Segmenter developer), template scenes creation &amp;lt;br&amp;gt;&lt;br /&gt;
B) update preprocessing pipeline - deep gray matter atlases included &amp;lt;br&amp;gt;&lt;br /&gt;
C) test and debug preprocesing pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
D) identified missing modules: atlas autocalibration for EM Segmentation scene, Island removal for ICC mask&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- Review currently deployed modules. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: reviewed firts seven subjects' outputs, added volume orientation module into pipeline (prevents ICBM atlas linear registration failures)&amp;lt;br&amp;gt;&lt;br /&gt;
- Fused ICC(brainmask) extraction module with EM Segmenter preprocessing. Three scenarious implemented: start with pre-extracted ICC mask (longitudinal studies case), run with ICC ectration, run with ICC extraction AND ICC correction before ICBM atlas preporcessing. &amp;lt;br&amp;gt;&lt;br /&gt;
- Completion of Human activities GUI (QC, ICC Correction) planned for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: Volume Orientation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: automated preprocessing pipeline for Slicer2 EM Segmenter test version deployed. Seven cases pre-processed.&lt;br /&gt;
- PET Quantitative measurements: Preliminary design specs discussion.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: BSplineRegistration (for non-linear registration), ResampleVolume2 (for atlases resampling based on image atlase templates registration). Local and Network runs are implemented, Cluster/GridWizard implementation pending.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Slicer EM Segmenter module: preprocessing design for Slicer2 EM Segmenter&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Adapting for Slicer2 EM Segmenter (mostly from pipelines and services for previous projects)&lt;br /&gt;
  -- Integration with FreeSurfer modules for bisafield correction, brainmask extraction, and linear registration of ICBM atlases&lt;br /&gt;
  -- Preprocessing updates for non-linear registration of ICBM atlases with Slicer2 (image re-orientation service designed)&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 29, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- EM Segmentaton pipeline: preprocessing results are being transferred to XNat (anonymized data, Central XNat) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Slicer EM Segmenter module: discussed agenda and scheduled a work meeting for Social Cognition Study image segmentation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Testing stage, 95% completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- SPL XNat server: verified data exchange via RESTfull web services.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 22, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Follow up with White Matter Lesion Segmenter and Scull Stripping Modules developers: Work in Progress&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Work in Progress, 60%+ completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Discussed SPINE image repository migration to XNat&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 15, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. &lt;br /&gt;
- Social Cognition Study: &lt;br /&gt;
Work-in-progress on intermediate (reconstruction) and results (resources) data storage at XNat.&lt;br /&gt;
&amp;lt;br&amp;gt;Reviewing and preparation more cases for EM Segmentor (Slicer 3.5) tuning.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* NA-MIC Project Week&lt;br /&gt;
Selecting candidate Slicer modules for other than Lesion EM Segmentation topics of Social Cognition study: Withe Matter Lesion Segmenter (UNC), Scull Stripping utility from UIOWA.&lt;br /&gt;
Reviewing issues of currently used Scull Stripping Slicer Extension and Slicer 3.5 EM Segmenter.&lt;br /&gt;
&amp;lt;br&amp;gt;XNat Data organizing training&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 1, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Preparation of Demo for NA-MIC work week: &lt;br /&gt;
- COPD Study. Added Remote pipepline start interface (represents real world scenario where Xnat repository, Processing modules and User are at different sites)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
- EM Segmentation. Added human activities steps to the workflow: ICC (brainmask) correction and EM Segmantation scena load per se.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 25, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Pilot workflow pipeline for EM Segmentation (all steps except user-activity step: ICC correction assignment and tracking)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 18, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Build and tested web services for EM Segmentation image preprocessing: DICOM-to-NRRD conversion, registration, skull stripping, image masking.&lt;br /&gt;
Started building workflow pipeline (subject to finish first version next week)&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Started Collecting Library of Slicer Build number vs. functional modules and extensions.&lt;br /&gt;
Plan for NAMIC project week: scheduled meetings for XNat data customization, Skull-stripping modules tuning, identified Social Cognition study cases that fail EM Segmentation processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 11, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Updating and verification of EM Segmentation Scenario&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Projects:ARRA:SlicerWF:UseCaseScenarios#Usecase_MS_lesion_Assessment&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Familiarizing with Slicer3.4/5 Modules required for implementation of EM Segmentation Scenario. Participation in debugging and/or usage tuning of Dicom Conversion, Registration, Skull Stripping, Masking, and Image Casting modules. &lt;br /&gt;
&lt;br /&gt;
* December 4, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Slicer3.4's EM Segmentation and Visual QC as part of image processing pipeline for Social Cognition Study for MS Patients.&lt;br /&gt;
Project emerged. EM Segmentation template creation debugged.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
Emphysema Measurements (COPD Study) - workflow stability and scalability test.&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 27, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Emphysema Measurements (COPD Study).&lt;br /&gt;
Added compensation for long running calculations and time-outs to the main computing pipeline.&lt;br /&gt;
Visual QC (work in progress)&lt;br /&gt;
** Infrastructure&lt;br /&gt;
XNat data structure customization, metadata storage, results consolidation: new feature request list creation (work in progress)&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 13, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
*** Pilot system for whole processing cycle for Emphysema Measurements (COPD Study) including the following:&lt;br /&gt;
Web query for CT session file list download&lt;br /&gt;
Pilot user interface for submitting the file list and starting processing pipeline&lt;br /&gt;
Notification about processing steps and failures&lt;br /&gt;
Upload results to XNat repository (at this stage results are uploaded into same folder where original scans are(*))&lt;br /&gt;
*** Immediate Plans&lt;br /&gt;
Complete Visual QC module&lt;br /&gt;
Design and implement meta-data transfer to XNat (including processing details and MRML files for loading images into the 3D Slicer)&lt;br /&gt;
&lt;br /&gt;
(*)Customization of results storage&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 6, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Tuned and debugged multiple subjects processing for: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat.&lt;br /&gt;
***Started working on quality control embedding into the above scenario. Plan to complete and video-record demo next week.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***Published general Product Integration scenario flow chart to collaborators' community. Discussion is open and in progress&lt;br /&gt;
&lt;br /&gt;
* October 30, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Piloted and tested the sequence: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat(1).&lt;br /&gt;
***Performance test of overall cycle: data transfer from remote serve is a bottleneck as expected&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data browsing features reviewed.&lt;br /&gt;
(1) Not automated yet&lt;br /&gt;
* October 23, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Defined COPD processing scenario with interoperability between Xnat, 3D Slicer Command Modules, Workflow, and Gridwizard Enterprise.&lt;br /&gt;
***Pilot version of Emphysema Measurements workflow pipeline deployed.&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data transfer features reviewed. Use account at XNat Central during learning curve.&lt;br /&gt;
***Feasibility test of 3D Slicer fiducials module for ROI highlights during QC and manual image processing activities. &lt;br /&gt;
* October 16, 2009&lt;br /&gt;
**Lung CT Scans Processing. Pilot project emerged. GenerateEmphysemaMeasurements module deployed as a webservice that submits jobs to computational cluster.&lt;br /&gt;
**EM Segmentation. Familiarized with GUI steps. Started working on automation steps outlining&lt;br /&gt;
**3D Slicer and XNat interaction. Got an overview from Wendy Plesniak.&lt;br /&gt;
* October 1 - 7, 2009&lt;br /&gt;
**Selected two first priority Projects: EM Segmentation of brain MRI images; Lung CT Scans Processing (COPD Study)&lt;br /&gt;
**Got initial outline of user requirements and design specs&lt;/div&gt;</summary>
		<author><name>Azaitsev</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=71095</id>
		<title>Projects:ARRA:SlicerWF</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=71095"/>
		<updated>2011-09-27T16:40:34Z</updated>

		<summary type="html">&lt;p&gt;Azaitsev: /* Quarterly Progress */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Projects:ARRASuplements|Back to Slicer ARRA home page]]&lt;br /&gt;
= Aim =&lt;br /&gt;
Supplement 3D Slicer and Extensible Neuroimaging Archive Toolkit (XNAT) with workflow management system. Provide integration and interoperability between 3D Slicer, XNAT Services and 3-rd party image processing applications and high performance computing systems. Implement it as within currently developed Structural Planning and Implementation in Neurological Exploration (SPINE) System.&lt;br /&gt;
&lt;br /&gt;
= SPINE Project Documentation =&lt;br /&gt;
[http://cni.bwh.harvard.edu/projects/spine/index.html SPINE Docs]&lt;br /&gt;
&lt;br /&gt;
= Presentations =&lt;br /&gt;
* Segmentation Workflow. PECS University Social Cognition Study.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:SlicerWF_NAC_PECS_Workflow.pdf]]&lt;br /&gt;
* EAB10_ARRA Annual Progress Report Slides.&amp;lt;br&amp;gt;&lt;br /&gt;
[[media:EAB10_ARRA_WF_2011_Zaitsev.ppt | Service Oriented Solutions for 3D Slicer. EAB10_ARRA_WF_2011. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:EAB10_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:NAMIC_ARRA_WF_2011_Zaitsev.ppt  | NAMIC Annual Report 04/2010-03/2011. NAMIC_ARRA_WF_2011_Zaitsev. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:NAMIC_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:Slicer_WF_Slicer4CARMAWorkflow.ppt  | CARMA Workflow. Cardiac Ablation Followup. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:Slicer_WF_Slicer4CARMAWorkflow.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* CARMA Project Beta release Demo Location: http://cni29.bwh.harvard.edu/SlicerWFDemo/index.php&lt;br /&gt;
&lt;br /&gt;
* Segmentation Workflows: Screenshots, scans' and study description : [[File:SlicerWF_EMSegmentProjectsReview.zip]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
= All Hands Meeting Pages =&lt;br /&gt;
* MIT 2011 Summer:&lt;br /&gt;
 Workflows Project [http://www.na-mic.org/Wiki/index.php/Summer_project_week_2011_Workflows_SOA MIT_2011_WorkFlow]&lt;br /&gt;
 Segmentation Project (MS Lesions)[http://www.na-mic.org/Wiki/index.php/2011_Summer_Project_Week_Customizing_EMSegmenter_pipelines_for_brain_lesions MIT_2011_LesionsSegmentation]&lt;br /&gt;
* Salt Lake City 2011 Winter [http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA SLC_2011_WorkFlow]&lt;br /&gt;
* MIT 2010 Summer [http://wiki.na-mic.org/Wiki/index.php/Summer_project_week_2010_Workflows_SOA MIT_2010_WorkFlow]&lt;br /&gt;
&lt;br /&gt;
= Research Plan =&lt;br /&gt;
*Create a stand-alone SPINE desktop agent with fully functional data exchange and communication mechanisms towards 3D Slicer and XNAT.&lt;br /&gt;
*Develop Service Oriented Architecture (SOA) SPINE System that will include 3D Slicer image processing modules deployed as web services as well as a workflow management system to orchestrate interaction between 3D Slicer, XNAT, and 3-rd party tools.&lt;br /&gt;
*Implement two-way control and communications between 3D Slicer and SPINE modules.&lt;br /&gt;
*Adapt SPINE System for cluster and grid computing scenarios.&lt;br /&gt;
*Provide with workflow and 3D Slicer web service wrappers editing tools.&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:UseCaseScenarios| Use Case scenarios]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PETCTWorkflow| PETCTWorkflow]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:AgingStudySegmentation| AgingStudySegmentation]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:TwoTensorTractography| TwoTensorTractography]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:LongitudinalMultimodalityRegistrationSuite| LongitudinalMultimodalityRegistrationSuite]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:MigrationJavaClients2QT| MigrationJavaClients2QT]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PediatricMSSegmentation| PediatricMSSegmentation]]&lt;br /&gt;
*[[DBP3:Utah:RegSegPipeline| MRI-based study and treatment of atrial fibrillation]]&lt;br /&gt;
&lt;br /&gt;
= Application Server / Workflow Engine Downloads =&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:WFEngineDownloads| Download Links]]&lt;br /&gt;
&lt;br /&gt;
=Key Personnel=&lt;br /&gt;
* Charles Gutmann, MD., 4%,  9-17-2009 through 9-16-2011&lt;br /&gt;
* Alexander Zaitsev, Ph.D., 75%, 9-17-2009 through 9-16-2011 &lt;br /&gt;
&lt;br /&gt;
=Annual Progress Statements =&lt;br /&gt;
'''2010-11''' &amp;lt;br&amp;gt;&lt;br /&gt;
The  April 2011 – March 2011 period was devoted on developing portable workflow solutions that can be deployed on end-users' workstations or notebooks with minimal or no system administration activities. This is in contrast to the server-side deployment. The following scenarios had been deployed and used for actual projects that require the following types of workflows: PET/CT registration and computation of biomarker driven brain physiological activities, Brain MRI Images segmentation,  MRI and MRI Angiography images pre-processing for cardiac ablation outcome estimation. Some  workflows (like EM Segmentation) had been utilizing various scenarios, some research projects  (like evaluation of chemotherapy outcome) require two types of workflows to assess physiological and structural changes. Starting from the 4th Quarter of 2011, the migration project had been emerged in order to embed Workflow GUIs into newly developed Slicer4 Suite. The existing rich client Java GUI applications are being re-written as C++/QT Sliceletts units, new modules (such as cardiac ablation project support) are had been written from scratch. The latter are being deployed from the Slicer4 GUI and act at a liaison between Slicer4 and Application Server containing  workflow and Slicer modules deployed as services. The feedback from the end users indicates that Workflow approach for the complex processing improves productivity, aids to the processing standardization and contributes to the overall experience using 3D Slicer&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* '''3d Qtr, 2011''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study: Follow-up with end-users. &lt;br /&gt;
*** End-users started a new study. The multi-study configuration support is confirmed&lt;br /&gt;
*** Debugging and workarounds of minor issues addressed&lt;br /&gt;
&lt;br /&gt;
** Left Atrium Ablation Assessment (CARMA Project)&lt;br /&gt;
*** Work on the custom build and packaging of the Slicer4 with CARMA workflow included (90% completion - pending Slicer4/QT compilation framework issues resolution)&lt;br /&gt;
*** Presentation and demo outside of NA-MIC community: Moscow Cardiological Center. Slicer4 is under evaluation, checking feasibility of 3T cardioMRIs segmentation&lt;br /&gt;
&lt;br /&gt;
** Multiple Sclerosis CLIMB Study&lt;br /&gt;
*** Reprocessing for lesion segmentation&lt;br /&gt;
*** Developed Web-based (Java EE 6) application for submitting cases to the workflows for EM Segmentation of MPRAGE and registration to PD/T2/FLAIR images. Deployed at end-users site, currently used for segmenting the cases that could not be segmented with in-house (Non-Slicer) algorithms.&lt;br /&gt;
&lt;br /&gt;
** EM Segmentation: &lt;br /&gt;
*** Embedded into the Web-based image processing suite (see CLIMB study above)&lt;br /&gt;
 &lt;br /&gt;
** User and developer documentation&lt;br /&gt;
*** Documenting steps for integrating 3D Slicer modules with OpenESB workflow engine&lt;br /&gt;
&lt;br /&gt;
* '''2d Qtr, 2011''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study: Second release deployed. &lt;br /&gt;
*** End-users completed the first Project and currently analyzing SUV values and clinical data&lt;br /&gt;
*** New features added: Human Brain Hemispheres segmentation, Scull-stripping for total SUV counts calculation, Flexibility of custom designed label look-up table usage (users can define ROI notation according to the Project needs)&lt;br /&gt;
&lt;br /&gt;
** Left Atrium Ablation Assessment (CARMA Project)&lt;br /&gt;
*** Completed workflow pipeline for automated pre-processing and manual intervention&lt;br /&gt;
*** Developed front-end GUI for the CARMA Project support in Slicer4.&lt;br /&gt;
*** Run the workflow with the end users during NAMIC Project Week&lt;br /&gt;
*** Evaluated feasibility of left atrium wall and post-ablation scar segmentation using Robust Statistical Segmentation (RSS). Identified necessary processing controls with RSS module designers&lt;br /&gt;
&lt;br /&gt;
** Multiple Sclerosis CLIMB Study&lt;br /&gt;
*** Reprocessing for lesion segmentation&lt;br /&gt;
*** Developed Web-based (Java EE 6) application for submitting cases to the workflows for EM Segmentation of MPRAGE and registration to PD/T2/FLAIR images (60% completion)&lt;br /&gt;
&lt;br /&gt;
** EM Segmentation: &lt;br /&gt;
*** Upgraded EM Segmentation services to Slicer 3.6.4&lt;br /&gt;
*** Added brain hemispheres segmentation module to the workflows (used for PET/CT Longitudinal study)&lt;br /&gt;
*** Work with EM Segmenter module developers on building pipelines for white matter lesion segmentation (work in progress)&lt;br /&gt;
&lt;br /&gt;
** Plans for the 3rd quarter&lt;br /&gt;
*** Migrate CARMA Project workflow to end-users&lt;br /&gt;
*** Packaging of Slicer4 Workflow modules and Slicer4 custom build distribution &lt;br /&gt;
*** Completion of Web-base segmentation and registration suite&lt;br /&gt;
*** Users and Developers Documentation&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* NAMIC Annual Progress Slides (April 2010 - March 2011):&lt;br /&gt;
&lt;br /&gt;
* '''1st Qtr, 2011''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study: Second release is under testing by end-users. &lt;br /&gt;
*** Added MRI registration to aid ROI drawing on PET scans&lt;br /&gt;
*** Improved SUV results reporting and added flexibility to update ROI lookup table&lt;br /&gt;
*** Automated EM Segmentation of MRI images for computing SUVs for white matter, CSF, and whole brain (80% completion)&lt;br /&gt;
*** Integration with SPECTRE scull stripping module (70% completion) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** EM Segmentation: Automated WF Pipelines are created &amp;lt;br&amp;gt;&lt;br /&gt;
*** Flexible atlas selection (Pediatric, etc) feature added&lt;br /&gt;
*** Workflows implemented for EM Segmenter 3.6.2 and 3.6.3 (1st Qtr 2011 release)&lt;br /&gt;
&lt;br /&gt;
** Cardiac ablation results follow-up: Workflow for registration and ROI selection of cardiac MRI and MR Angiography &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Wrokflow and Web Services for prospective DTI tractography modules (currently written as Matlab modules at PNL) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Web Services for SPECTRE Scull stripping module&lt;br /&gt;
*** Accuracy and performance tuning&lt;br /&gt;
*** 50% completion&lt;br /&gt;
&lt;br /&gt;
** Migration Front End GUI to Slicer4/QT:&lt;br /&gt;
*** EM Segmentation&lt;br /&gt;
*** Cardiac Ablation Study&lt;br /&gt;
&lt;br /&gt;
** DICOM Uploader and Desktop Browser for XNat Image repository (alpha version - tested for MGH MS Center studies, proposed to use with MI2B2 Clients and Services)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''4th Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study and EM Segmentation for Aging Study are deployed at end-user sites and actively used for research. &lt;br /&gt;
** Adopted EM Segmentation preprocessing pipeline for HIV Study: high resolution SPGR images, integration with FreeSurfer brainmask extraction outputs; integration of Slicer SPECTRE module for brainmask extraction is in progress.&lt;br /&gt;
** The following post-release upgrades had been implemented based on end-user feedback: Application Server basic controls are performed from Rich Client GUI as alternative to traditional IT administration activities. The controls are implemented on point-and-click bases and include web services and workflow application deployment and upgrades, application server start and stop as well as warning end user when the server is not accepting request.&lt;br /&gt;
** Added DICOM downloads and results uploads of PET/CT pipelines from and to XNat Repository&lt;br /&gt;
** Created Services and Workflow for Matlab Prototypes modules. Case Study: tractography for DTI images&lt;br /&gt;
** Extended XNAT integration services:&lt;br /&gt;
*** Browsing capabilities of XNat data repository from the Workflow Applications&lt;br /&gt;
*** Improved DICOM upload and download performance&lt;br /&gt;
*** Added Metadata organizing services for uploaded DICOM images: header data extraction, image snapshots creation. &lt;br /&gt;
** Started project for Rich Client GUI migration from Java desktop application to build into SLicer4 QT modules. This affects mostly front-end GUI and has the following approaches: distribution with the Slicer4, end-user will select desired workflow application from Slicer4 menu while QT-written modules provide with the same functionality as Java Rich Clients. Case Study for the Migration process: registration suite for longitudinal studies that include multi-modality images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* '''3d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Concentrated on building downloadable workflow applications that could run both in desktop (new) and server environment, and that require minimum IT administrative resources. The desktop deployment is in compliance with Slicer3 general deployment concept.&lt;br /&gt;
*** The following use case scenario had been chosen: PET/CT image processing for longitudinal studies, EM Segmentation for longitudinal Aging Study.&lt;br /&gt;
** Released workflow application for PET/CT image processing for longitudinal studies. Provided end users with training and documentation.&lt;br /&gt;
*** The PET/CT processing workflow was designed to be a general application used whenever both structural patterns and metabolic activities are within the research scope. &lt;br /&gt;
*** The desktop version is tuned to use minimal computer resources, so the automates processing instances do not interfere with human activities. Automated activities may include, for example, registration and PET scan's standard uptake values computing, and manual human activities may include image cropping, quality control, and labeling voxels of interest.&lt;br /&gt;
** Core services and EM Segmentation preprocessing workflow was build for retrospective Aging Study. Tuned the Slicer3 webservices for processing low grade images acquired in mid 90s. Entire workflow is implemented with Slicer3 only modules and can be deployed locally and on the servers. Usage of Service Oriented Architecture (SOA) as a core technological approach allowed reusing most of the web services that had been build for PET/CT project. &lt;br /&gt;
** Continued embedding Slicer3 application and modules into previously released processing pipelines: replaced MIPAV with Slicer3 GUI for lesion assessment step in the multi-center Pediatric MS Cohort image processing &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''2d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Completed Social Cognition Workflow Implementation. This includes EM Segmetnation pre- and post-processing pipelines, data tracking, and integration with 3d party image processing utilities, as well as processing results acquired manually with Slicer GUI.  &lt;br /&gt;
** Multi-modality image registration and ROI selection/alignment workflow for longitudinal studies. &lt;br /&gt;
*** Use case: PET/CT image processing for longitudinal studies. &lt;br /&gt;
*** Build portable library of Slicer modules as web services and workflow that are deployed and run on a end-users' worksatations without utilization of SPL and other servers. The web services include novel Slicer3 modules, such as BRAINSFit and BRAINSResamle &lt;br /&gt;
*** Started working with Slicer3 developers on Slicer 3.8 GUI wizard to communicate with workflow instances.&lt;br /&gt;
** Participated at NA-MIC Summer 2010 Project Week: [[Summer_project_week_2010_Workflows_SOA]]&lt;br /&gt;
&lt;br /&gt;
=Progress=&lt;br /&gt;
* September 2, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT Project:&lt;br /&gt;
* New study follow-up&lt;br /&gt;
* Debugging SUV consolidated computation: V2.1 requires all or no MRIs for all cases. Does not work correctly when only  a subset of patients has MRIs&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* August 26, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project:&lt;br /&gt;
* Packaging on Max OS X 64-bit: troubleshooting QT 4.6 (build tree) QT 4.7 (make package) conflicts&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
3D Slicer WF. General&lt;br /&gt;
* 3D Slicer and WF Modules presentation at MGH Radiation Oncology&lt;br /&gt;
&amp;lt;br&amp;gt;  &lt;br /&gt;
&lt;br /&gt;
* August 19, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation&lt;br /&gt;
* Deployed first release (Human Brain EM Segmentation) web request application&lt;br /&gt;
* End-users requested EM Segmentation of MS lesion on PD images (feasibility is being evaluated with EM Segmenter Team)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
3D Slicer WF. General&lt;br /&gt;
* Preparation of 3D Slicer and WF Modules presentation for MGH&lt;br /&gt;
&amp;lt;br&amp;gt;  &lt;br /&gt;
&lt;br /&gt;
* August 12, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
* Migrating build to updated Slicer4 environment  (PythonQT and new added module dependencies issues)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation&lt;br /&gt;
* Tested and reviewed EM Segmentation web app on end-users' data&lt;br /&gt;
* Updated workflow, so EM Segmentation is performed on T1 after registration to T2 or FLAIR. This gives more accurate results comparing to segmentation of high resolution image followed by resampling (have to use nearest neighbor interpolation to retain actual label values) of label map &lt;br /&gt;
&lt;br /&gt;
* August 5, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT&lt;br /&gt;
* Follow-up with end users with new Study setup&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
CARMA Project&lt;br /&gt;
* Documentation (Work in progress)&lt;br /&gt;
* Plans for next week: custom packaging (Mac Snow Leopard 64 bit), building extension, documentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation&lt;br /&gt;
* Stress-test of online segmentation requests suite for  [http://www.slicer.org/slicerWiki/index.php/EMSegmenter-Tasks#Additional_Use_Cases CLIMB Study](for BWH MS Center)&lt;br /&gt;
* Reason for building online suite: the Group is Using mostly MAC OS Tiger machines for legacy reasnos, the most recent Slicer3 builds as well as QT don't work on those machines (QT4.x runtime could not be installed).&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* July 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA Project&lt;br /&gt;
* Documentation (Work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation&lt;br /&gt;
* Work on alpha-release of online submission of segmentation requests (for BWH MS Center)&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* July 22, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
Vacation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* July 8, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
3D Slicer in General and CARMA Project&lt;br /&gt;
* Presentation and life demo at Cardiology Research Center (Moscow, Russia) [[File:RussianCardiologyCenterCARMA2011.ppt]]&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* July 1, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA V1.0&lt;br /&gt;
* Migration to new QT building environment (Mac 10 Snow Leopard). &lt;br /&gt;
* Building custom package. Issues: new features (not only WF related) are not shown on the menu of the resulting application&lt;br /&gt;
* Comparing preprocessing workflow results with published in literature data (our module produces better alignment)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*June 24, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
Project Week:&lt;br /&gt;
* Testing RSS module for left atrial wall scar segmentation&lt;br /&gt;
* Testing EM Segmenter for lesion detection on PD (requested by end-users) and FLAIR images&lt;br /&gt;
&lt;br /&gt;
EM Segmentation &lt;br /&gt;
* Web-based segmentation and registration module for MS Center. Goal: facilitate 3D SLicer modules for the cases that could not be processed with in-house build DTS+ algorithm&lt;br /&gt;
* Pipeline: Segment MPGR or T1 (user's choice), Register MPGR to PD/T2, Resample Segmentation Map to PD/T2. Completion: 60-70%.&lt;br /&gt;
* The rest will be done manually or via lesion segmentation with EM Segmenter.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* June 17, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
Preparation for Project Week&lt;br /&gt;
&lt;br /&gt;
* June 10, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
CARMA V.1.0&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code completed and tested&lt;br /&gt;
* Packaging as extension is pending (Subject for Summer 2011 Project week)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Debugging consolidation results issue(SUVs for manual and automated segmentation) &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* June 3, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Deployed on end-user's machine&lt;br /&gt;
* TODO next week: fix SUV results consolidation issue (when MRI segmented ROI got SUV computed for some subjects, only those subjects' SUVs are being added into consolidated report. &amp;quot;Raw&amp;quot; SUV values per subject are generated as expected)  &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 27, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Ready for deployment. New Features: hemispheres EM Segmentation, automated ICC/brainmask extraction using EM Segmenter, fixed controls for MRI conversion and registration&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 20, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General / PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Hemispheres EM Segmentation - adjusted for required label lookup table&lt;br /&gt;
* Use cases added for EM Segmenter General Project: http://www.slicer.org/slicerWiki/index.php/EMSegmenter-Tasks#EMSegmenter_use_cases&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SPECTRE Scull Stripping&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* The new version to be tested on coming week (After PETCT MRI processing migrated to Hemispheres scenario )&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* May 13, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General / PETCT V1.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Hemispheres EM Segmentation - technically works with labal values hardcoded in Slicer EM Segmenter - need to add manual label value edition step&lt;br /&gt;
* PETCT WF Cut for Java GUI (Pending Hemispheres label update completion). Next release will be in QT4.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* May 6, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (QA of EM Segmenter module, work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* April 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Open Discussion for Packaging WF QT Modules as Slicer4 extensions (waiting for SOPs)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review supported projects http://wiki.na-mic.org/Wiki/index.php/File:SlicerWF_EMSegmentProjectsReview.zip &lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (required by Study)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Slicer Modules General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Standardizing Crop Volumes Output (with A. Fedorov's module). Review for required updates of existing product (PET/CT, CARMA)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Open Discussion for Packaging WF QT Modules as Slicer4 extensions (waiting for SOPs)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review supported projects http://wiki.na-mic.org/Wiki/index.php/File:SlicerWF_EMSegmentProjectsReview.zip &lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (required by Study)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Slicer Modules General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Standardizing Crop Volumes Output (with A. Fedorov's module)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 22, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Beta release ready. Demo Location: http://cni29.bwh.harvard.edu/SlicerWFDemo/index.php&lt;br /&gt;
* TODO: Tutorial. Original inputs copy/renaming&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 15, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Adding App server auto-config features&lt;br /&gt;
* Finalizing the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 08, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Second release beta build tested on cosutmer side &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review registration quality (with Dr. Meier). Angiography images' Resampling tuned. &lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 01, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the second release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
XNat Integration&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* (Java) GUI for Project Browsing and DICOM Series Upload. Post-upload DICOM processing tested and debugged&amp;lt;br&amp;gt;&lt;br /&gt;
* Ready for integration with mi2b2 client.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Migrated to Latest Slicer 3.6.3 stable release: only the Input scene had to be updated, the API remained the same&lt;br /&gt;
* Tested EM Segmenter with CMTK4Slicer extension - processing takes to much time on Linux_64bit machine, rolled back to BRAINSFit registration. When used on Mac OS X build, the Slicer could not start (bug report 1126).&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SPECTRE Scull Stripping:&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Testes for various use cases: the module is extremely sensitive to T1 MRI quality (does not work for most MRIs from PET/CT project&lt;br /&gt;
* TODO next week: check for FLAIR images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Slicer4 QT GUI and Cropping activity in progress.&amp;lt;br&amp;gt;&lt;br /&gt;
* Tried direct MRA to MRA registration option: resampling with LMRI registration transforms works better.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Extra VOI labels revised&lt;br /&gt;
* Debugging of SUV results' renormalization step&lt;br /&gt;
* TODO: ICC extraction / whole brain total uptake computing; EM Segmentation for R_WM, L_WM SUV computing and BPH estimation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SCULL STRIPPING/SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Installed and tested CLI option on Linux_64bit platform&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Workflow interruption before BSPline registraton: BPEL Module completed. Slicer4 QT GUI and Cropping activity in prorgess.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Implemented and Tested with end-users proposed changes: denormalization of SUV results, adding more VOI labels, added FLAIR MRI in addition to T1s for VOI drawing&lt;br /&gt;
* Tested manual ICC extraction using PET scans: works satisfactory with island removal and cropping followed by threshold level labeling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4&lt;br /&gt;
* Change proposed: interrupt workflow after affine registration and have user crop the VOI. This is to prevent excessive deformations for BSpline registration and resampling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4. User has option to choose the atlas that fits better for the given subject (NOTE: hardcoding must be rewritten for atlas linking)&lt;br /&gt;
* PETCT test - the problem is that T1s are low resolution and with contrast. Proposed using T1s without contrast&lt;br /&gt;
* PETCT change request: users wants to compute SUV for entire ICC. Had demo how to segment brainmask/ICC using PET scan. The derived brainmask label can be used for SUV computation.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - cmpleted&lt;br /&gt;
* Sample cases run - excessive deformation after BSpline registration hase&lt;br /&gt;
* Next week plan - pull tuning controls to front-end of pipeline API, start working of QT module for CARMA registration&lt;br /&gt;
* May consider other than BRAINSFit registration modules&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Design plan for change request: more VOI labels, add FLAIR in addition to T1 for VOI drawing, T1s segmentation&lt;br /&gt;
* Tested segmentation for sample cases - artifacts from poor quality MRIs lead to exclusion of parts of ICC from segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Completed troubleshooting of EMSegmenter module calling from Java (need TCL libs to be pulled from Slicer environment)&lt;br /&gt;
* Tested EMSegmenter autoruns for HIV and Pediatric MS patiens. Work as expected, subject to improvement of PED MS case segmentation by building better skull/neck/air atalses&lt;br /&gt;
* Suggested usage of two subsets of atalases: with and without neck. The Subject MRIs have to be cropped accordingly or best fit atlas has to be selected&lt;br /&gt;
* Made no-neck cropped atlas collection for default EMSegmenter scenario&lt;br /&gt;
* Tested with PET/CT study MRI cases - see above &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - in progress&lt;br /&gt;
* Next week goal - have back end processing ready&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Longitudinal Study&lt;br /&gt;
* Added MRI registration to the pipeline&lt;br /&gt;
* Troubleshooting of complex XML schema issues on Linux machines (some modules working on MAC do not work on Linux). As a workaround - did not include MRI convert and register part into base BPEL module. Used separate services (transparent for end-user)&lt;br /&gt;
* TODO next week for change request completion: explicit pixel type casting for MRI in BRAINSFit, VOI MRML scene update (currently MRI added on top of schema)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* February 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipeline for Pediatric MRI. Same scenario as for HIV Project, icbm pediatric atlases (Completed, verified)&lt;br /&gt;
* Collected NIH healthy brain development atlases: various age ranges from 4.5 to 18 yo. Converted to Slicer readable format &lt;br /&gt;
* Work on web services for the new automated EM Segmenter module (release Nov 10 - current). Verified task completion both for adult and pediatric images. Discussed tuning parameters for work load balance on workstations.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Started working on MRI registration to the reference CT scans. &lt;br /&gt;
* Design specs for optional White Matter segmentation for SUV computing.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* February 4, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipelines for Pediatric MRI (in progress)&lt;br /&gt;
* Adapting Pediatric T1 atlases for &amp;quot;Human Brain&amp;quot; build-in EM Segmentation wizard (in progress)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 28, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Verifying EM Segmenter module for latest builds and HIV/PED MS Studies (report pending)&lt;br /&gt;
* Work with SPECTRE module developers with pediatric MRI brainmask extraction&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* January 21, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Compiling plan for WF FrontEnd GUI migration to Slicer4/QT Widgets&lt;br /&gt;
* Preparing for annual progress report&lt;br /&gt;
&lt;br /&gt;
* January 14, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI: Integrated into the Slicer4 as Slicelet (or thin Client)&lt;br /&gt;
* Participation at AHM-2011, discussing integration of SPECTRE module and updated approach to EM-Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA&lt;br /&gt;
&lt;br /&gt;
* January 7, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* HIV project workflow delivered. Major additions relate to user convenience: &lt;br /&gt;
- Project-specific parameter settings, importing T1s and brainmasks from FreeSurfer outputs with conversion to NIFTI, resampling brainmask to original scans and automatied subject addition.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Follow up with end user: need to add MRI scans, if available, addition and registration to CT in order to ease VOI drawings.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
 &lt;br /&gt;
* December 31, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Follow-up with user Experience for AGING Study Segmentation (Positive feedback)&lt;br /&gt;
* Target date for HIV project delivery - next week&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Self-training for QT widget development&amp;lt;br&amp;gt;&lt;br /&gt;
* Outlined Workflow Rich Clients migration strategy from Java to QT/Slicer4:&amp;lt;br&amp;gt;&lt;br /&gt;
** Use Java Stubs (similar to SPECTRE integration) or file binding for envocation of workflow pipelines. (See SOAP remark below)&lt;br /&gt;
** Direct Web Servisec calls must be wrapped into REST protocol. The reason: NON-commerchial QT kit does not include SOAP protocol for web servises.&lt;br /&gt;
** The GUI will be implemented as page widget or QT dialog GUI forms called from within Slicer4.&lt;br /&gt;
** Communications between Slicer4 and WF GUI will be set via child-parent and signal-slot relations&lt;br /&gt;
* Worked on a Prototype for Basic EM Segmentation QT widget (70% complete). Will work on integrtion with SLicer4 during the AHM-2010&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
XNAT Integration&lt;br /&gt;
* Debugged XNAT RESTFul API usage for uplaoding DICOM series followed by header data extraction and image snapshots creation&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Added compensation for failed atlas registration (subject for old poor quality pseudo-T1 images): blank probability maps are created in case of failure.&lt;br /&gt;
* Data preparation module for FreeSurfer data import near completion. Expected time for deployment at end-users workstations - first week of January&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Discussed strategy for EM Segmentation pipeline solutions collection (K. Pohl, R. Kikinis)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* RE-using the same core workflow as for 1-channel EM Segmentation of AGING STUDY cases&lt;br /&gt;
* Added data input preparation module: ICC label mask preparation and skull-stripping based on FreeSurfer brainmask output volume.&lt;br /&gt;
* Two-channel EM segmentation pipeline (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE / GENERAL Development &amp;lt;br&amp;gt;&lt;br /&gt;
* Worked on plans for migrating fro rich workflow Java clients to embedded workflow windows inside the Slicer.&amp;lt;br&amp;gt;&lt;br /&gt;
The embedded workflow management clients are to be implemented with QT/PyQT toolkits&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
INTEGRATION WITH XNAT:&amp;lt;br&amp;gt;&lt;br /&gt;
* Automated DICOM series upload with triggering DICOM headers parsing at XNat site (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress. &lt;br /&gt;
- Results upload to XNat (Completed) &amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat based on user's input (Project + Subject + PET or CT session / scan) (Completed)&amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat - perfomance boosting solution for downloads found , web services services are created, relinking for the client side in progress &amp;lt;br&amp;gt;&lt;br /&gt;
- Xnat querying for subjects and automated subject addition into the workflow (In Progress) &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-segmentation module added for auto correction of segmentation results. Particularly - relabeling CSF voxels segmented as Air inside the intracranial cavity. This was requested by end-users after processing images with zero-signals in CSF voxels &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting automated dual-echo DICOM images conversion and split into two NRRD volumes&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT / EM Segmentation pipeline:&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting memory allocation issues for scull-stripping module SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
COPD Project:&amp;lt;br&amp;gt;&lt;br /&gt;
* Benchmark test for accelerated DICOM downloads from XNat (remoote XNat Central server): we can handle at least 6 cases (4 CT scans in each) per hour, which is compatible with current workload quotes on SPL cluster processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* December 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Deployed Version 1. &amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Test project chosen as a closest match to registration scenario: Pediatric MS Cases from MGH - requires periodic image preview for different &lt;br /&gt;
modalities taken from vaious time points. Label maps for VOIs resampling is also required.&lt;br /&gt;
&lt;br /&gt;
* November 26, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user. Version 1 is complete&amp;lt;br&amp;gt;&lt;br /&gt;
* Started working on integration with XNat&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on input data organizing modules&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 19, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user (70% done)&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Universal Registration Workflow for Longitudinal Studies - design specs in progress&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 12, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Minor tuning to EM Segmentation template as of users' feedback&lt;br /&gt;
* Users started using the workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed input data conversion from Genesis to Slicer native or NIFTI format. Our help may be needed in input data organizing.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Tuned application according to co-laborators (PNL) needs&amp;lt;br&amp;gt;&lt;br /&gt;
* The webservices and BPEL workflow application are tested ready to accept computation requests from PNL case tracking system &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Discussed Universal Registration Workflow for Longitudinal Studies&lt;br /&gt;
* Started the thread about possible cooperation with Children hospital's image processing pipelines and integration with Xnat &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 5, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Webservices and workflow pilot project created and deployed on Psychiatry Neuroimaging Laboratory subnet &amp;lt;br&amp;gt;&lt;br /&gt;
* The V.1.0 deployment is scheduled for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 29, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Most of functionality is completed. Some volume statistics post processing is pending&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL EM SEGMENTATION Pipeline: &amp;lt;br&amp;gt;&lt;br /&gt;
* The SPECTRE scull stripping module. Started integration into EMS workflow. Made some test runs from Slicer GUI&amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Identified as a candidate for Workflow Application&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 22, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* All back-end functionality are implemented&amp;lt;br&amp;gt;&lt;br /&gt;
* EM Segmentation scene usability is confirmed by end-user&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for next week: add Label Statistics computation for CSF/Brain/ICC &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 15, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* The latest (October) builds of Slicer 3.6.2 produced acceptable results. This was verified by the target users. The EM Segmentation will be performed on Slicer 3.6.2 or later&amp;lt;br&amp;gt;&lt;br /&gt;
* The new Web services had been created and added to the pipeline as optional processing steps: Biasfield correction (implement novel N2ITKBiasFieldCorrection module) and Volume's scalar datatype casting (as workaround for Biasfield correction module not preserving image scalar datatype - the bug is filed) &amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed the Front-End GUI design with target users. The design pattern is taken from the PETCT project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 8, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-deployment support. Tuned CT registration as of user's feedback.&lt;br /&gt;
* Adapting to the Single Slicer build: Slicer 3.6.2. Found label duplicates in the label lookup table - will ask user if it's tolerable. Waiting for the Slicer 3.6.2 build that contains all required modules. Rolling back label tag appending code for SUVs - the latest Slicer build appends the tags.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Resumed development. The priorities are set for usage of Slicer 3.6.2 - subject for EM Segmentation scene tuning. Continued coding for Scene creation for Slicer 2.8 - as a backup option for ongoing research project.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 1, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized V1.0 release based on end-user feedback: updates relate mostly to error proofing and SUV values representation&lt;br /&gt;
* Post-deployment support. Users pre-processed first set of patients &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* September 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* System deployed and tested at End Users' site.&amp;lt;br&amp;gt;Users are trained to perform all tasks required by the workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
* Got positive feedback with suggestions on Slicer Scenes' layouts improvement and PET scans' SUV (standard uptake values) results display&lt;br /&gt;
* Two distribution packages are assembled: Lunix and MAC OS versions. The difference in two packages is in specific Slicer3.6/3.7 builds - subject to Slicer Linux builds debugging.&amp;lt;br&amp;gt; As a workaround for Linux deployment - multiple Slicer builds are used to perform various tasks (registration, opening editing scenes in Slicer, SUV computing)&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for coming week - finalize V1.0 release based on end-user feedback&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Embedded SUV computations into the workflow (as system calls - will be translated into web service later)&amp;lt;br&amp;gt;&lt;br /&gt;
* Pre-release demo for end users.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Create and debug EM Segmenter scenes template for Slicer 3.6 and 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* September 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation - workflow pipeline and deployment verified&amp;lt;br&amp;gt;&lt;br /&gt;
* Tested EM Segmentation scenes within Slicer 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
* Started migration of EM Segmentation to Slicer 3.6. Discovered issues had been reported to EM Segmenter module designers &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* August 29 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation completed. Preprocessing Pipleine completed 80% (subject for input registration parameters tuning) &amp;lt;br&amp;gt;&lt;br /&gt;
* Most webservices (for registration and resampling steps) had been taken and re-used from PET/CT ROI/Longitudinal Study - showing the advantage of service-oriented software design and deployment.&lt;br /&gt;
* Continued on distribution and deployment of the service/workflow applications: on PET/CT and AGING STUDY projects.&lt;br /&gt;
&lt;br /&gt;
PEDIATRIC Multiple Sclerosis Cohort. Support of multi-center distributed processing project&amp;lt;br&amp;gt;&lt;br /&gt;
* Introduced Slicer 3.6 for the MS Lesion Assessment step performed at Mayo Clinic. Images are being transferred from image repository at BWH and automatically opened and arranged within Slicer GUI for reading.  This was replacement of Client GUI using MIPAV that stopped working on new computers at Mayo Clinic.&lt;br /&gt;
The images are being loaded via generated MRML Scenes same way as in PET/CT and AGING STUDY projects &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* August 22 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Preprocessing pipeline merge with SUV computations &amp;lt;br&amp;gt;&lt;br /&gt;
- QA for SUVs computation was performed by Wendy Plesniak for images with known uptake values. &amp;lt;br&amp;gt;&lt;br /&gt;
- Discovered that image cropping step (not related to automated registration pipeline and SUVs computing) smoothes the images by doing interpolation when used with default settings. Got suggestions from Steve Piper using Nearest-Neighbor interpolation (&amp;quot;no interpolation&amp;quot;) for a time being&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
- This is the new project candidate. Requested for the images with failed manual segmentation and/or segmentation with FreeSurfer. The EM Segmentation run showed most acceptable results on one of the problem images back in February &amp;lt;br&amp;gt;&lt;br /&gt;
- The workflow will be developed and deployed similar to PET/CT ROI Longitudinal study approach - all preprocessing steps will be done with Slicer modules, all runs will be performed on local end-user machines.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
 &lt;br /&gt;
&lt;br /&gt;
* August 15 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- First 5 cases with 3-4 time points preprocessed for SUVs computation&lt;br /&gt;
&lt;br /&gt;
* August 8 2010&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Testing of installation and operation at users' site (Performed by Wendy Plesniak)&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* July 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Delivered beta version of registration pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
- Prepared installation and user manuals &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* June 11, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Registration modules completed &amp;lt;br&amp;gt;&lt;br /&gt;
- Irregular cases registration problem solved (when whole body and brain only scans are mixed for a timepoint)&amp;lt;br&amp;gt;&lt;br /&gt;
- Live demo of case setup and registration workflow for end users. Real case with 4 timepoints used&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Coming week plans&amp;lt;br&amp;gt;&lt;br /&gt;
- Adjust workflow based on end users' feedback&amp;lt;br&amp;gt;&lt;br /&gt;
- Integration with SUVs computing for PET scans&amp;lt;br&amp;gt;&lt;br /&gt;
- GUI for workflows dispatching and data organizing&amp;lt;br&amp;gt;&lt;br /&gt;
- (TBD) Integration with 4D time series analysis Slicer module&amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
* May 28, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- Migration to the latest Slicer 3.6 release candidate &amp;lt;br&amp;gt;&lt;br /&gt;
- Added webservice for new registration module: BRAINSFit &amp;lt;br&amp;gt;&lt;br /&gt;
- Test runs for new patients with 4 timepoints' scans &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Plans for next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI &amp;lt;br&amp;gt;&lt;br /&gt;
- processing workflow demo for end user &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 21, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Pilot version of portable web services and automated workflow tested: &amp;lt;br&amp;gt;&lt;br /&gt;
Linux: workflow and visual review passed&amp;lt;br&amp;gt;&lt;br /&gt;
Stress test for 25 timepoints passed &amp;lt;br&amp;gt;&lt;br /&gt;
MAC OS: workflow passed, visual review failing when PET/CT images are loaded into GUI simultaneously (bug report submitted)&amp;lt;br&amp;gt;&lt;br /&gt;
Windows: need to adapt command line modules and workflow management system to sygwin environment&amp;lt;br&amp;gt;&lt;br /&gt;
Plans for next week: integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI&lt;br /&gt;
&lt;br /&gt;
* May 7, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Selected registration and resampling modules with more precise and stable outputs. &amp;lt;br&amp;gt;&lt;br /&gt;
Started building portable web services and automated workflow &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 30, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- manual walk through the processing steps: ROI cropping, registration/resampling, PET pharmaceutical DICOM data retention. &amp;lt;br&amp;gt;&lt;br /&gt;
- testing workflow and web services packages distribution to end-users' machines&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* April 23, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : testing various registration and re-sampling algorithms (work in progress)&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation: as of collaborators' request, run existing EM Segmentation workflow for older low resolution pseudo-T1 images. The EM Segmentation works for those images with manual sampling. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 16, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
  Social Cognition Study: started Cortical Thickness Measurement module build (bases on NA-MIC ARCTIC pipeline) &amp;lt;br&amp;gt;&lt;br /&gt;
  PET/CT ROI/Longitudinal Study Registration : Design specs, PET-to-CT images registration tests on training data. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 9, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. GUI update based on end-user experience.&amp;lt;br&amp;gt;&lt;br /&gt;
User request: automated label maps' volumes calculation (Currently possible from Slicer3 GUI)&amp;lt;br&amp;gt; &lt;br /&gt;
PET/CT ROI Project. Initial design specs discussion with end-users and co-developers&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure&lt;br /&gt;
Verification of segmentation workflow GUI: from registering new case to reviewing results&amp;lt;br&amp;gt;&lt;br /&gt;
Cross study test of segmentation workflow: MGH/MS Center data - success,  HIV Project data - some EM Segmentation scene tuning is needed &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*&lt;br /&gt;
* April 2, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. Segmentation workflow completed&amp;lt;br&amp;gt;&lt;br /&gt;
* Coming Week plans:&amp;lt;br&amp;gt;&lt;br /&gt;
- Document Segmentation Workflow. Follow up with end users &amp;lt;br&amp;gt;&lt;br /&gt;
- Start with Cortical Thickness and ROI-in-longitudinal studies workflows&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* March 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All essential processing and workflow interaction clients are ready.&amp;lt;br&amp;gt;&lt;br /&gt;
- Completed segmentation for 10 out of 50 patients. The remaining cases will be finalized upon manual lesion segmentation and QC verification of WM/GM/CSF and Deep GM segmentation's. &amp;lt;br&amp;gt;&lt;br /&gt;
- TODO next week: refine QC GUI and data tracking / progress monitoring schema. &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&amp;lt;br&amp;gt;&lt;br /&gt;
- New Slicer3 web services added: re-slicing with reference image volume, casting image scalar type &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
* March 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Segmentation maps Merging Services for GM/WM/CSF (Slicer EM Segemnter), Lesion (Slicer, Manual), and Deep GM (FreeSurfer)  &amp;lt;br&amp;gt;&lt;br /&gt;
- Deep GM segmentation pipeline adopted as optional service for Social Cognition Study (22 out of 50 cases processed) &amp;lt;br&amp;gt;&lt;br /&gt;
- (In progress) GUI client for Launching Segmentation results merging with optional Deep GM segmentation with FreeSurfer &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- Complete GUI Client for Segmentation result merging &amp;lt;br&amp;gt;&lt;br /&gt;
- Progress Monitoring services for entire Study processing: EM Segmenter Preprocessing, EM Segmentation, Lesion Segmentation (including human activities assignments), Deep GM segmentation, and results consolidation. &amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* March 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All 50 cases went through &amp;quot;basic&amp;quot; One-channel EM segmentation (GM/WM/CSF) &amp;lt;br&amp;gt;&lt;br /&gt;
- Basic pipeline start-up command line client created: user has two options - request brainmask extraction or provide with previously extracted brainmask for a given subject &amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison of GM/WN/CSF performed for Slicer EM Segmenter and FreeSurfer recon-all (used with default settings). &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmenter provides more accurate output &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmentation pipeline runs faster (40 minutes vs 12 hrs when no brainmask extraction requested) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO:&amp;lt;br&amp;gt;&lt;br /&gt;
- merging modules for automatic 1-channel EM segmentation and manual lesion segmentation &amp;lt;br&amp;gt;&lt;br /&gt;
- Emerge Cortical Thickness pipeline project: use NAC ARCTIC processing steps and modules &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Selected stable EM Segmentation scenario: White Matter, Gray Matter, and Cerebrospinal Fluid &amp;lt;br&amp;gt;&lt;br /&gt;
- First 16 cases are segmented for selected scenario. Nine more cases are preprocessed for EM Segmentation.&amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison to segmentation with FreeSurfer showed better accuracy for Slicer2 EMSegmenter &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure &amp;lt;br&amp;gt;&lt;br /&gt;
- Three prerpcocessed cases failed during volume ICC masking with in-house build utility. Evaluated switching to Slicer3 Mask and island removing modules.&amp;lt;br&amp;gt;&lt;br /&gt;
- Initial design specs discussion for cortical thickness measurement pipeline. ARCTIC pipeline selected. ARCTIC preprocessing steps signifficantly overlap with EM Segmentation preprocessing workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
  &lt;br /&gt;
* February 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: &amp;lt;br&amp;gt;&lt;br /&gt;
A) parameters tuning for EM Segmenter itself (work with EM Segmenter developer), template scenes creation &amp;lt;br&amp;gt;&lt;br /&gt;
B) update preprocessing pipeline - deep gray matter atlases included &amp;lt;br&amp;gt;&lt;br /&gt;
C) test and debug preprocesing pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
D) identified missing modules: atlas autocalibration for EM Segmentation scene, Island removal for ICC mask&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- Review currently deployed modules. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: reviewed firts seven subjects' outputs, added volume orientation module into pipeline (prevents ICBM atlas linear registration failures)&amp;lt;br&amp;gt;&lt;br /&gt;
- Fused ICC(brainmask) extraction module with EM Segmenter preprocessing. Three scenarious implemented: start with pre-extracted ICC mask (longitudinal studies case), run with ICC ectration, run with ICC extraction AND ICC correction before ICBM atlas preporcessing. &amp;lt;br&amp;gt;&lt;br /&gt;
- Completion of Human activities GUI (QC, ICC Correction) planned for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: Volume Orientation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: automated preprocessing pipeline for Slicer2 EM Segmenter test version deployed. Seven cases pre-processed.&lt;br /&gt;
- PET Quantitative measurements: Preliminary design specs discussion.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: BSplineRegistration (for non-linear registration), ResampleVolume2 (for atlases resampling based on image atlase templates registration). Local and Network runs are implemented, Cluster/GridWizard implementation pending.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Slicer EM Segmenter module: preprocessing design for Slicer2 EM Segmenter&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Adapting for Slicer2 EM Segmenter (mostly from pipelines and services for previous projects)&lt;br /&gt;
  -- Integration with FreeSurfer modules for bisafield correction, brainmask extraction, and linear registration of ICBM atlases&lt;br /&gt;
  -- Preprocessing updates for non-linear registration of ICBM atlases with Slicer2 (image re-orientation service designed)&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 29, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- EM Segmentaton pipeline: preprocessing results are being transferred to XNat (anonymized data, Central XNat) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Slicer EM Segmenter module: discussed agenda and scheduled a work meeting for Social Cognition Study image segmentation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Testing stage, 95% completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- SPL XNat server: verified data exchange via RESTfull web services.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 22, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Follow up with White Matter Lesion Segmenter and Scull Stripping Modules developers: Work in Progress&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Work in Progress, 60%+ completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Discussed SPINE image repository migration to XNat&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 15, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. &lt;br /&gt;
- Social Cognition Study: &lt;br /&gt;
Work-in-progress on intermediate (reconstruction) and results (resources) data storage at XNat.&lt;br /&gt;
&amp;lt;br&amp;gt;Reviewing and preparation more cases for EM Segmentor (Slicer 3.5) tuning.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* NA-MIC Project Week&lt;br /&gt;
Selecting candidate Slicer modules for other than Lesion EM Segmentation topics of Social Cognition study: Withe Matter Lesion Segmenter (UNC), Scull Stripping utility from UIOWA.&lt;br /&gt;
Reviewing issues of currently used Scull Stripping Slicer Extension and Slicer 3.5 EM Segmenter.&lt;br /&gt;
&amp;lt;br&amp;gt;XNat Data organizing training&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 1, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Preparation of Demo for NA-MIC work week: &lt;br /&gt;
- COPD Study. Added Remote pipepline start interface (represents real world scenario where Xnat repository, Processing modules and User are at different sites)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
- EM Segmentation. Added human activities steps to the workflow: ICC (brainmask) correction and EM Segmantation scena load per se.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 25, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Pilot workflow pipeline for EM Segmentation (all steps except user-activity step: ICC correction assignment and tracking)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 18, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Build and tested web services for EM Segmentation image preprocessing: DICOM-to-NRRD conversion, registration, skull stripping, image masking.&lt;br /&gt;
Started building workflow pipeline (subject to finish first version next week)&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Started Collecting Library of Slicer Build number vs. functional modules and extensions.&lt;br /&gt;
Plan for NAMIC project week: scheduled meetings for XNat data customization, Skull-stripping modules tuning, identified Social Cognition study cases that fail EM Segmentation processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 11, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Updating and verification of EM Segmentation Scenario&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Projects:ARRA:SlicerWF:UseCaseScenarios#Usecase_MS_lesion_Assessment&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Familiarizing with Slicer3.4/5 Modules required for implementation of EM Segmentation Scenario. Participation in debugging and/or usage tuning of Dicom Conversion, Registration, Skull Stripping, Masking, and Image Casting modules. &lt;br /&gt;
&lt;br /&gt;
* December 4, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Slicer3.4's EM Segmentation and Visual QC as part of image processing pipeline for Social Cognition Study for MS Patients.&lt;br /&gt;
Project emerged. EM Segmentation template creation debugged.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
Emphysema Measurements (COPD Study) - workflow stability and scalability test.&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 27, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Emphysema Measurements (COPD Study).&lt;br /&gt;
Added compensation for long running calculations and time-outs to the main computing pipeline.&lt;br /&gt;
Visual QC (work in progress)&lt;br /&gt;
** Infrastructure&lt;br /&gt;
XNat data structure customization, metadata storage, results consolidation: new feature request list creation (work in progress)&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 13, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
*** Pilot system for whole processing cycle for Emphysema Measurements (COPD Study) including the following:&lt;br /&gt;
Web query for CT session file list download&lt;br /&gt;
Pilot user interface for submitting the file list and starting processing pipeline&lt;br /&gt;
Notification about processing steps and failures&lt;br /&gt;
Upload results to XNat repository (at this stage results are uploaded into same folder where original scans are(*))&lt;br /&gt;
*** Immediate Plans&lt;br /&gt;
Complete Visual QC module&lt;br /&gt;
Design and implement meta-data transfer to XNat (including processing details and MRML files for loading images into the 3D Slicer)&lt;br /&gt;
&lt;br /&gt;
(*)Customization of results storage&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 6, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Tuned and debugged multiple subjects processing for: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat.&lt;br /&gt;
***Started working on quality control embedding into the above scenario. Plan to complete and video-record demo next week.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***Published general Product Integration scenario flow chart to collaborators' community. Discussion is open and in progress&lt;br /&gt;
&lt;br /&gt;
* October 30, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Piloted and tested the sequence: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat(1).&lt;br /&gt;
***Performance test of overall cycle: data transfer from remote serve is a bottleneck as expected&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data browsing features reviewed.&lt;br /&gt;
(1) Not automated yet&lt;br /&gt;
* October 23, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Defined COPD processing scenario with interoperability between Xnat, 3D Slicer Command Modules, Workflow, and Gridwizard Enterprise.&lt;br /&gt;
***Pilot version of Emphysema Measurements workflow pipeline deployed.&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data transfer features reviewed. Use account at XNat Central during learning curve.&lt;br /&gt;
***Feasibility test of 3D Slicer fiducials module for ROI highlights during QC and manual image processing activities. &lt;br /&gt;
* October 16, 2009&lt;br /&gt;
**Lung CT Scans Processing. Pilot project emerged. GenerateEmphysemaMeasurements module deployed as a webservice that submits jobs to computational cluster.&lt;br /&gt;
**EM Segmentation. Familiarized with GUI steps. Started working on automation steps outlining&lt;br /&gt;
**3D Slicer and XNat interaction. Got an overview from Wendy Plesniak.&lt;br /&gt;
* October 1 - 7, 2009&lt;br /&gt;
**Selected two first priority Projects: EM Segmentation of brain MRI images; Lung CT Scans Processing (COPD Study)&lt;br /&gt;
**Got initial outline of user requirements and design specs&lt;/div&gt;</summary>
		<author><name>Azaitsev</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=70814</id>
		<title>Projects:ARRA:SlicerWF</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=70814"/>
		<updated>2011-09-06T12:43:23Z</updated>

		<summary type="html">&lt;p&gt;Azaitsev: /* Progress */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Projects:ARRASuplements|Back to Slicer ARRA home page]]&lt;br /&gt;
= Aim =&lt;br /&gt;
Supplement 3D Slicer and Extensible Neuroimaging Archive Toolkit (XNAT) with workflow management system. Provide integration and interoperability between 3D Slicer, XNAT Services and 3-rd party image processing applications and high performance computing systems. Implement it as within currently developed Structural Planning and Implementation in Neurological Exploration (SPINE) System.&lt;br /&gt;
&lt;br /&gt;
= SPINE Project Documentation =&lt;br /&gt;
[http://cni.bwh.harvard.edu/projects/spine/index.html SPINE Docs]&lt;br /&gt;
&lt;br /&gt;
= Presentations =&lt;br /&gt;
* Segmentation Workflow. PECS University Social Cognition Study.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:SlicerWF_NAC_PECS_Workflow.pdf]]&lt;br /&gt;
* EAB10_ARRA Annual Progress Report Slides.&amp;lt;br&amp;gt;&lt;br /&gt;
[[media:EAB10_ARRA_WF_2011_Zaitsev.ppt | Service Oriented Solutions for 3D Slicer. EAB10_ARRA_WF_2011. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:EAB10_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:NAMIC_ARRA_WF_2011_Zaitsev.ppt  | NAMIC Annual Report 04/2010-03/2011. NAMIC_ARRA_WF_2011_Zaitsev. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:NAMIC_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:Slicer_WF_Slicer4CARMAWorkflow.ppt  | CARMA Workflow. Cardiac Ablation Followup. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:Slicer_WF_Slicer4CARMAWorkflow.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* CARMA Project Beta release Demo Location: http://cni29.bwh.harvard.edu/SlicerWFDemo/index.php&lt;br /&gt;
&lt;br /&gt;
* Segmentation Workflows: Screenshots, scans' and study description : [[File:SlicerWF_EMSegmentProjectsReview.zip]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
= All Hands Meeting Pages =&lt;br /&gt;
* MIT 2011 Summer:&lt;br /&gt;
 Workflows Project [http://www.na-mic.org/Wiki/index.php/Summer_project_week_2011_Workflows_SOA MIT_2011_WorkFlow]&lt;br /&gt;
 Segmentation Project (MS Lesions)[http://www.na-mic.org/Wiki/index.php/2011_Summer_Project_Week_Customizing_EMSegmenter_pipelines_for_brain_lesions MIT_2011_LesionsSegmentation]&lt;br /&gt;
* Salt Lake City 2011 Winter [http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA SLC_2011_WorkFlow]&lt;br /&gt;
* MIT 2010 Summer [http://wiki.na-mic.org/Wiki/index.php/Summer_project_week_2010_Workflows_SOA MIT_2010_WorkFlow]&lt;br /&gt;
&lt;br /&gt;
= Research Plan =&lt;br /&gt;
*Create a stand-alone SPINE desktop agent with fully functional data exchange and communication mechanisms towards 3D Slicer and XNAT.&lt;br /&gt;
*Develop Service Oriented Architecture (SOA) SPINE System that will include 3D Slicer image processing modules deployed as web services as well as a workflow management system to orchestrate interaction between 3D Slicer, XNAT, and 3-rd party tools.&lt;br /&gt;
*Implement two-way control and communications between 3D Slicer and SPINE modules.&lt;br /&gt;
*Adapt SPINE System for cluster and grid computing scenarios.&lt;br /&gt;
*Provide with workflow and 3D Slicer web service wrappers editing tools.&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:UseCaseScenarios| Use Case scenarios]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PETCTWorkflow| PETCTWorkflow]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:AgingStudySegmentation| AgingStudySegmentation]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:TwoTensorTractography| TwoTensorTractography]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:LongitudinalMultimodalityRegistrationSuite| LongitudinalMultimodalityRegistrationSuite]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:MigrationJavaClients2QT| MigrationJavaClients2QT]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PediatricMSSegmentation| PediatricMSSegmentation]]&lt;br /&gt;
*[[DBP3:Utah:RegSegPipeline| MRI-based study and treatment of atrial fibrillation]]&lt;br /&gt;
&lt;br /&gt;
= Application Server / Workflow Engine Downloads =&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:WFEngineDownloads| Download Links]]&lt;br /&gt;
&lt;br /&gt;
=Key Personnel=&lt;br /&gt;
* Charles Gutmann, MD., 4%,  9-17-2009 through 9-16-2011&lt;br /&gt;
* Alexander Zaitsev, Ph.D., 75%, 9-17-2009 through 9-16-2011 &lt;br /&gt;
&lt;br /&gt;
=Annual Progress Statements =&lt;br /&gt;
'''2010-11''' &amp;lt;br&amp;gt;&lt;br /&gt;
The  April 2011 – March 2011 period was devoted on developing portable workflow solutions that can be deployed on end-users' workstations or notebooks with minimal or no system administration activities. This is in contrast to the server-side deployment. The following scenarios had been deployed and used for actual projects that require the following types of workflows: PET/CT registration and computation of biomarker driven brain physiological activities, Brain MRI Images segmentation,  MRI and MRI Angiography images pre-processing for cardiac ablation outcome estimation. Some  workflows (like EM Segmentation) had been utilizing various scenarios, some research projects  (like evaluation of chemotherapy outcome) require two types of workflows to assess physiological and structural changes. Starting from the 4th Quarter of 2011, the migration project had been emerged in order to embed Workflow GUIs into newly developed Slicer4 Suite. The existing rich client Java GUI applications are being re-written as C++/QT Sliceletts units, new modules (such as cardiac ablation project support) are had been written from scratch. The latter are being deployed from the Slicer4 GUI and act at a liaison between Slicer4 and Application Server containing  workflow and Slicer modules deployed as services. The feedback from the end users indicates that Workflow approach for the complex processing improves productivity, aids to the processing standardization and contributes to the overall experience using 3D Slicer&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
=Quarterly Progress=&lt;br /&gt;
&lt;br /&gt;
* '''2d Qtr, 2011''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study: Second release deployed. &lt;br /&gt;
*** End-users completed the first Project and currently analyzing SUV values and clinical data&lt;br /&gt;
*** New features added: Human Brain Hemispheres segmentation, Scull-stripping for total SUV counts calculation, Flexibility of custom designed label look-up table usage (users can define ROI notation according to the Project needs)&lt;br /&gt;
&lt;br /&gt;
** Left Atrium Ablation Assessment (CARMA Project)&lt;br /&gt;
*** Completed workflow pipeline for automated pre-processing and manual intervention&lt;br /&gt;
*** Developed front-end GUI for the CARMA Project support in Slicer4.&lt;br /&gt;
*** Run the workflow with the end users during NAMIC Project Week&lt;br /&gt;
*** Evaluated feasibility of left atrium wall and post-ablation scar segmentation using Robust Statistical Segmentation (RSS). Identified necessary processing controls with RSS module designers&lt;br /&gt;
&lt;br /&gt;
** Multiple Sclerosis CLIMB Study&lt;br /&gt;
*** Reprocessing for lesion segmentation&lt;br /&gt;
*** Developed Web-based (Java EE 6) application for submitting cases to the workflows for EM Segmentation of MPRAGE and registration to PD/T2/FLAIR images (60% completion)&lt;br /&gt;
&lt;br /&gt;
** EM Segmentation: &lt;br /&gt;
*** Upgraded EM Segmentation services to Slicer 3.6.4&lt;br /&gt;
*** Added brain hemispheres segmentation module to the workflows (used for PET/CT Longitudinal study)&lt;br /&gt;
*** Work with EM Segmenter module developers on building pipelines for white matter lesion segmentation (work in progress)&lt;br /&gt;
&lt;br /&gt;
** Plans for the 3rd quarter&lt;br /&gt;
*** Migrate CARMA Project workflow to end-users&lt;br /&gt;
*** Packaging of Slicer4 Workflow modules and Slicer4 custom build distribution &lt;br /&gt;
*** Completion of Web-base segmentation and registration suite&lt;br /&gt;
*** Users and Developers Documentation&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* NAMIC Annual Progress Slides (April 2010 - March 2011):&lt;br /&gt;
&lt;br /&gt;
* '''1st Qtr, 2011''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study: Second release is under testing by end-users. &lt;br /&gt;
*** Added MRI registration to aid ROI drawing on PET scans&lt;br /&gt;
*** Improved SUV results reporting and added flexibility to update ROI lookup table&lt;br /&gt;
*** Automated EM Segmentation of MRI images for computing SUVs for white matter, CSF, and whole brain (80% completion)&lt;br /&gt;
*** Integration with SPECTRE scull stripping module (70% completion) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** EM Segmentation: Automated WF Pipelines are created &amp;lt;br&amp;gt;&lt;br /&gt;
*** Flexible atlas selection (Pediatric, etc) feature added&lt;br /&gt;
*** Workflows implemented for EM Segmenter 3.6.2 and 3.6.3 (1st Qtr 2011 release)&lt;br /&gt;
&lt;br /&gt;
** Cardiac ablation results follow-up: Workflow for registration and ROI selection of cardiac MRI and MR Angiography &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Wrokflow and Web Services for prospective DTI tractography modules (currently written as Matlab modules at PNL) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Web Services for SPECTRE Scull stripping module&lt;br /&gt;
*** Accuracy and performance tuning&lt;br /&gt;
*** 50% completion&lt;br /&gt;
&lt;br /&gt;
** Migration Front End GUI to Slicer4/QT:&lt;br /&gt;
*** EM Segmentation&lt;br /&gt;
*** Cardiac Ablation Study&lt;br /&gt;
&lt;br /&gt;
** DICOM Uploader and Desktop Browser for XNat Image repository (alpha version - tested for MGH MS Center studies, proposed to use with MI2B2 Clients and Services)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''4th Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study and EM Segmentation for Aging Study are deployed at end-user sites and actively used for research. &lt;br /&gt;
** Adopted EM Segmentation preprocessing pipeline for HIV Study: high resolution SPGR images, integration with FreeSurfer brainmask extraction outputs; integration of Slicer SPECTRE module for brainmask extraction is in progress.&lt;br /&gt;
** The following post-release upgrades had been implemented based on end-user feedback: Application Server basic controls are performed from Rich Client GUI as alternative to traditional IT administration activities. The controls are implemented on point-and-click bases and include web services and workflow application deployment and upgrades, application server start and stop as well as warning end user when the server is not accepting request.&lt;br /&gt;
** Added DICOM downloads and results uploads of PET/CT pipelines from and to XNat Repository&lt;br /&gt;
** Created Services and Workflow for Matlab Prototypes modules. Case Study: tractography for DTI images&lt;br /&gt;
** Extended XNAT integration services:&lt;br /&gt;
*** Browsing capabilities of XNat data repository from the Workflow Applications&lt;br /&gt;
*** Improved DICOM upload and download performance&lt;br /&gt;
*** Added Metadata organizing services for uploaded DICOM images: header data extraction, image snapshots creation. &lt;br /&gt;
** Started project for Rich Client GUI migration from Java desktop application to build into SLicer4 QT modules. This affects mostly front-end GUI and has the following approaches: distribution with the Slicer4, end-user will select desired workflow application from Slicer4 menu while QT-written modules provide with the same functionality as Java Rich Clients. Case Study for the Migration process: registration suite for longitudinal studies that include multi-modality images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* '''3d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Concentrated on building downloadable workflow applications that could run both in desktop (new) and server environment, and that require minimum IT administrative resources. The desktop deployment is in compliance with Slicer3 general deployment concept.&lt;br /&gt;
*** The following use case scenario had been chosen: PET/CT image processing for longitudinal studies, EM Segmentation for longitudinal Aging Study.&lt;br /&gt;
** Released workflow application for PET/CT image processing for longitudinal studies. Provided end users with training and documentation.&lt;br /&gt;
*** The PET/CT processing workflow was designed to be a general application used whenever both structural patterns and metabolic activities are within the research scope. &lt;br /&gt;
*** The desktop version is tuned to use minimal computer resources, so the automates processing instances do not interfere with human activities. Automated activities may include, for example, registration and PET scan's standard uptake values computing, and manual human activities may include image cropping, quality control, and labeling voxels of interest.&lt;br /&gt;
** Core services and EM Segmentation preprocessing workflow was build for retrospective Aging Study. Tuned the Slicer3 webservices for processing low grade images acquired in mid 90s. Entire workflow is implemented with Slicer3 only modules and can be deployed locally and on the servers. Usage of Service Oriented Architecture (SOA) as a core technological approach allowed reusing most of the web services that had been build for PET/CT project. &lt;br /&gt;
** Continued embedding Slicer3 application and modules into previously released processing pipelines: replaced MIPAV with Slicer3 GUI for lesion assessment step in the multi-center Pediatric MS Cohort image processing &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''2d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Completed Social Cognition Workflow Implementation. This includes EM Segmetnation pre- and post-processing pipelines, data tracking, and integration with 3d party image processing utilities, as well as processing results acquired manually with Slicer GUI.  &lt;br /&gt;
** Multi-modality image registration and ROI selection/alignment workflow for longitudinal studies. &lt;br /&gt;
*** Use case: PET/CT image processing for longitudinal studies. &lt;br /&gt;
*** Build portable library of Slicer modules as web services and workflow that are deployed and run on a end-users' worksatations without utilization of SPL and other servers. The web services include novel Slicer3 modules, such as BRAINSFit and BRAINSResamle &lt;br /&gt;
*** Started working with Slicer3 developers on Slicer 3.8 GUI wizard to communicate with workflow instances.&lt;br /&gt;
** Participated at NA-MIC Summer 2010 Project Week: [[Summer_project_week_2010_Workflows_SOA]]&lt;br /&gt;
&lt;br /&gt;
=Progress=&lt;br /&gt;
* September 2, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT Project:&lt;br /&gt;
* New study follow-up&lt;br /&gt;
* Debugging SUV consolidated computation: V2.1 requires all or no MRIs for all cases. Does not work correctly when only  a subset of patients has MRIs&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* August 26, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project:&lt;br /&gt;
* Packaging on Max OS X 64-bit: troubleshooting QT 4.6 (build tree) QT 4.7 (make package) conflicts&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
3D Slicer WF. General&lt;br /&gt;
* 3D Slicer and WF Modules presentation at MGH Radiation Oncology&lt;br /&gt;
&amp;lt;br&amp;gt;  &lt;br /&gt;
&lt;br /&gt;
* August 19, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation&lt;br /&gt;
* Deployed first release (Human Brain EM Segmentation) web request application&lt;br /&gt;
* End-users requested EM Segmentation of MS lesion on PD images (feasibility is being evaluated with EM Segmenter Team)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
3D Slicer WF. General&lt;br /&gt;
* Preparation of 3D Slicer and WF Modules presentation for MGH&lt;br /&gt;
&amp;lt;br&amp;gt;  &lt;br /&gt;
&lt;br /&gt;
* August 12, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
* Migrating build to updated Slicer4 environment  (PythonQT and new added module dependencies issues)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation&lt;br /&gt;
* Tested and reviewed EM Segmentation web app on end-users' data&lt;br /&gt;
* Updated workflow, so EM Segmentation is performed on T1 after registration to T2 or FLAIR. This gives more accurate results comparing to segmentation of high resolution image followed by resampling (have to use nearest neighbor interpolation to retain actual label values) of label map &lt;br /&gt;
&lt;br /&gt;
* August 5, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT&lt;br /&gt;
* Follow-up with end users with new Study setup&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
CARMA Project&lt;br /&gt;
* Documentation (Work in progress)&lt;br /&gt;
* Plans for next week: custom packaging (Mac Snow Leopard 64 bit), building extension, documentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation&lt;br /&gt;
* Stress-test of online segmentation requests suite for  [http://www.slicer.org/slicerWiki/index.php/EMSegmenter-Tasks#Additional_Use_Cases CLIMB Study](for BWH MS Center)&lt;br /&gt;
* Reason for building online suite: the Group is Using mostly MAC OS Tiger machines for legacy reasnos, the most recent Slicer3 builds as well as QT don't work on those machines (QT4.x runtime could not be installed).&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* July 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA Project&lt;br /&gt;
* Documentation (Work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation&lt;br /&gt;
* Work on alpha-release of online submission of segmentation requests (for BWH MS Center)&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* July 22, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
Vacation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* July 8, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
3D Slicer in General and CARMA Project&lt;br /&gt;
* Presentation and life demo at Cardiology Research Center (Moscow, Russia) [[File:RussianCardiologyCenterCARMA2011.ppt]]&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* July 1, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA V1.0&lt;br /&gt;
* Migration to new QT building environment (Mac 10 Snow Leopard). &lt;br /&gt;
* Building custom package. Issues: new features (not only WF related) are not shown on the menu of the resulting application&lt;br /&gt;
* Comparing preprocessing workflow results with published in literature data (our module produces better alignment)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*June 24, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
Project Week:&lt;br /&gt;
* Testing RSS module for left atrial wall scar segmentation&lt;br /&gt;
* Testing EM Segmenter for lesion detection on PD (requested by end-users) and FLAIR images&lt;br /&gt;
&lt;br /&gt;
EM Segmentation &lt;br /&gt;
* Web-based segmentation and registration module for MS Center. Goal: facilitate 3D SLicer modules for the cases that could not be processed with in-house build DTS+ algorithm&lt;br /&gt;
* Pipeline: Segment MPGR or T1 (user's choice), Register MPGR to PD/T2, Resample Segmentation Map to PD/T2. Completion: 60-70%.&lt;br /&gt;
* The rest will be done manually or via lesion segmentation with EM Segmenter.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* June 17, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
Preparation for Project Week&lt;br /&gt;
&lt;br /&gt;
* June 10, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
CARMA V.1.0&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code completed and tested&lt;br /&gt;
* Packaging as extension is pending (Subject for Summer 2011 Project week)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Debugging consolidation results issue(SUVs for manual and automated segmentation) &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* June 3, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Deployed on end-user's machine&lt;br /&gt;
* TODO next week: fix SUV results consolidation issue (when MRI segmented ROI got SUV computed for some subjects, only those subjects' SUVs are being added into consolidated report. &amp;quot;Raw&amp;quot; SUV values per subject are generated as expected)  &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 27, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Ready for deployment. New Features: hemispheres EM Segmentation, automated ICC/brainmask extraction using EM Segmenter, fixed controls for MRI conversion and registration&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 20, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General / PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Hemispheres EM Segmentation - adjusted for required label lookup table&lt;br /&gt;
* Use cases added for EM Segmenter General Project: http://www.slicer.org/slicerWiki/index.php/EMSegmenter-Tasks#EMSegmenter_use_cases&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SPECTRE Scull Stripping&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* The new version to be tested on coming week (After PETCT MRI processing migrated to Hemispheres scenario )&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* May 13, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General / PETCT V1.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Hemispheres EM Segmentation - technically works with labal values hardcoded in Slicer EM Segmenter - need to add manual label value edition step&lt;br /&gt;
* PETCT WF Cut for Java GUI (Pending Hemispheres label update completion). Next release will be in QT4.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* May 6, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (QA of EM Segmenter module, work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* April 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Open Discussion for Packaging WF QT Modules as Slicer4 extensions (waiting for SOPs)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review supported projects http://wiki.na-mic.org/Wiki/index.php/File:SlicerWF_EMSegmentProjectsReview.zip &lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (required by Study)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Slicer Modules General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Standardizing Crop Volumes Output (with A. Fedorov's module). Review for required updates of existing product (PET/CT, CARMA)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Open Discussion for Packaging WF QT Modules as Slicer4 extensions (waiting for SOPs)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review supported projects http://wiki.na-mic.org/Wiki/index.php/File:SlicerWF_EMSegmentProjectsReview.zip &lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (required by Study)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Slicer Modules General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Standardizing Crop Volumes Output (with A. Fedorov's module)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 22, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Beta release ready. Demo Location: http://cni29.bwh.harvard.edu/SlicerWFDemo/index.php&lt;br /&gt;
* TODO: Tutorial. Original inputs copy/renaming&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 15, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Adding App server auto-config features&lt;br /&gt;
* Finalizing the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 08, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Second release beta build tested on cosutmer side &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review registration quality (with Dr. Meier). Angiography images' Resampling tuned. &lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 01, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the second release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
XNat Integration&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* (Java) GUI for Project Browsing and DICOM Series Upload. Post-upload DICOM processing tested and debugged&amp;lt;br&amp;gt;&lt;br /&gt;
* Ready for integration with mi2b2 client.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Migrated to Latest Slicer 3.6.3 stable release: only the Input scene had to be updated, the API remained the same&lt;br /&gt;
* Tested EM Segmenter with CMTK4Slicer extension - processing takes to much time on Linux_64bit machine, rolled back to BRAINSFit registration. When used on Mac OS X build, the Slicer could not start (bug report 1126).&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SPECTRE Scull Stripping:&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Testes for various use cases: the module is extremely sensitive to T1 MRI quality (does not work for most MRIs from PET/CT project&lt;br /&gt;
* TODO next week: check for FLAIR images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Slicer4 QT GUI and Cropping activity in progress.&amp;lt;br&amp;gt;&lt;br /&gt;
* Tried direct MRA to MRA registration option: resampling with LMRI registration transforms works better.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Extra VOI labels revised&lt;br /&gt;
* Debugging of SUV results' renormalization step&lt;br /&gt;
* TODO: ICC extraction / whole brain total uptake computing; EM Segmentation for R_WM, L_WM SUV computing and BPH estimation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SCULL STRIPPING/SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Installed and tested CLI option on Linux_64bit platform&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Workflow interruption before BSPline registraton: BPEL Module completed. Slicer4 QT GUI and Cropping activity in prorgess.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Implemented and Tested with end-users proposed changes: denormalization of SUV results, adding more VOI labels, added FLAIR MRI in addition to T1s for VOI drawing&lt;br /&gt;
* Tested manual ICC extraction using PET scans: works satisfactory with island removal and cropping followed by threshold level labeling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4&lt;br /&gt;
* Change proposed: interrupt workflow after affine registration and have user crop the VOI. This is to prevent excessive deformations for BSpline registration and resampling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4. User has option to choose the atlas that fits better for the given subject (NOTE: hardcoding must be rewritten for atlas linking)&lt;br /&gt;
* PETCT test - the problem is that T1s are low resolution and with contrast. Proposed using T1s without contrast&lt;br /&gt;
* PETCT change request: users wants to compute SUV for entire ICC. Had demo how to segment brainmask/ICC using PET scan. The derived brainmask label can be used for SUV computation.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - cmpleted&lt;br /&gt;
* Sample cases run - excessive deformation after BSpline registration hase&lt;br /&gt;
* Next week plan - pull tuning controls to front-end of pipeline API, start working of QT module for CARMA registration&lt;br /&gt;
* May consider other than BRAINSFit registration modules&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Design plan for change request: more VOI labels, add FLAIR in addition to T1 for VOI drawing, T1s segmentation&lt;br /&gt;
* Tested segmentation for sample cases - artifacts from poor quality MRIs lead to exclusion of parts of ICC from segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Completed troubleshooting of EMSegmenter module calling from Java (need TCL libs to be pulled from Slicer environment)&lt;br /&gt;
* Tested EMSegmenter autoruns for HIV and Pediatric MS patiens. Work as expected, subject to improvement of PED MS case segmentation by building better skull/neck/air atalses&lt;br /&gt;
* Suggested usage of two subsets of atalases: with and without neck. The Subject MRIs have to be cropped accordingly or best fit atlas has to be selected&lt;br /&gt;
* Made no-neck cropped atlas collection for default EMSegmenter scenario&lt;br /&gt;
* Tested with PET/CT study MRI cases - see above &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - in progress&lt;br /&gt;
* Next week goal - have back end processing ready&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Longitudinal Study&lt;br /&gt;
* Added MRI registration to the pipeline&lt;br /&gt;
* Troubleshooting of complex XML schema issues on Linux machines (some modules working on MAC do not work on Linux). As a workaround - did not include MRI convert and register part into base BPEL module. Used separate services (transparent for end-user)&lt;br /&gt;
* TODO next week for change request completion: explicit pixel type casting for MRI in BRAINSFit, VOI MRML scene update (currently MRI added on top of schema)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* February 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipeline for Pediatric MRI. Same scenario as for HIV Project, icbm pediatric atlases (Completed, verified)&lt;br /&gt;
* Collected NIH healthy brain development atlases: various age ranges from 4.5 to 18 yo. Converted to Slicer readable format &lt;br /&gt;
* Work on web services for the new automated EM Segmenter module (release Nov 10 - current). Verified task completion both for adult and pediatric images. Discussed tuning parameters for work load balance on workstations.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Started working on MRI registration to the reference CT scans. &lt;br /&gt;
* Design specs for optional White Matter segmentation for SUV computing.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* February 4, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipelines for Pediatric MRI (in progress)&lt;br /&gt;
* Adapting Pediatric T1 atlases for &amp;quot;Human Brain&amp;quot; build-in EM Segmentation wizard (in progress)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 28, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Verifying EM Segmenter module for latest builds and HIV/PED MS Studies (report pending)&lt;br /&gt;
* Work with SPECTRE module developers with pediatric MRI brainmask extraction&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* January 21, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Compiling plan for WF FrontEnd GUI migration to Slicer4/QT Widgets&lt;br /&gt;
* Preparing for annual progress report&lt;br /&gt;
&lt;br /&gt;
* January 14, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI: Integrated into the Slicer4 as Slicelet (or thin Client)&lt;br /&gt;
* Participation at AHM-2011, discussing integration of SPECTRE module and updated approach to EM-Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA&lt;br /&gt;
&lt;br /&gt;
* January 7, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* HIV project workflow delivered. Major additions relate to user convenience: &lt;br /&gt;
- Project-specific parameter settings, importing T1s and brainmasks from FreeSurfer outputs with conversion to NIFTI, resampling brainmask to original scans and automatied subject addition.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Follow up with end user: need to add MRI scans, if available, addition and registration to CT in order to ease VOI drawings.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
 &lt;br /&gt;
* December 31, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Follow-up with user Experience for AGING Study Segmentation (Positive feedback)&lt;br /&gt;
* Target date for HIV project delivery - next week&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Self-training for QT widget development&amp;lt;br&amp;gt;&lt;br /&gt;
* Outlined Workflow Rich Clients migration strategy from Java to QT/Slicer4:&amp;lt;br&amp;gt;&lt;br /&gt;
** Use Java Stubs (similar to SPECTRE integration) or file binding for envocation of workflow pipelines. (See SOAP remark below)&lt;br /&gt;
** Direct Web Servisec calls must be wrapped into REST protocol. The reason: NON-commerchial QT kit does not include SOAP protocol for web servises.&lt;br /&gt;
** The GUI will be implemented as page widget or QT dialog GUI forms called from within Slicer4.&lt;br /&gt;
** Communications between Slicer4 and WF GUI will be set via child-parent and signal-slot relations&lt;br /&gt;
* Worked on a Prototype for Basic EM Segmentation QT widget (70% complete). Will work on integrtion with SLicer4 during the AHM-2010&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
XNAT Integration&lt;br /&gt;
* Debugged XNAT RESTFul API usage for uplaoding DICOM series followed by header data extraction and image snapshots creation&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Added compensation for failed atlas registration (subject for old poor quality pseudo-T1 images): blank probability maps are created in case of failure.&lt;br /&gt;
* Data preparation module for FreeSurfer data import near completion. Expected time for deployment at end-users workstations - first week of January&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Discussed strategy for EM Segmentation pipeline solutions collection (K. Pohl, R. Kikinis)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* RE-using the same core workflow as for 1-channel EM Segmentation of AGING STUDY cases&lt;br /&gt;
* Added data input preparation module: ICC label mask preparation and skull-stripping based on FreeSurfer brainmask output volume.&lt;br /&gt;
* Two-channel EM segmentation pipeline (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE / GENERAL Development &amp;lt;br&amp;gt;&lt;br /&gt;
* Worked on plans for migrating fro rich workflow Java clients to embedded workflow windows inside the Slicer.&amp;lt;br&amp;gt;&lt;br /&gt;
The embedded workflow management clients are to be implemented with QT/PyQT toolkits&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
INTEGRATION WITH XNAT:&amp;lt;br&amp;gt;&lt;br /&gt;
* Automated DICOM series upload with triggering DICOM headers parsing at XNat site (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress. &lt;br /&gt;
- Results upload to XNat (Completed) &amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat based on user's input (Project + Subject + PET or CT session / scan) (Completed)&amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat - perfomance boosting solution for downloads found , web services services are created, relinking for the client side in progress &amp;lt;br&amp;gt;&lt;br /&gt;
- Xnat querying for subjects and automated subject addition into the workflow (In Progress) &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-segmentation module added for auto correction of segmentation results. Particularly - relabeling CSF voxels segmented as Air inside the intracranial cavity. This was requested by end-users after processing images with zero-signals in CSF voxels &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting automated dual-echo DICOM images conversion and split into two NRRD volumes&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT / EM Segmentation pipeline:&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting memory allocation issues for scull-stripping module SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
COPD Project:&amp;lt;br&amp;gt;&lt;br /&gt;
* Benchmark test for accelerated DICOM downloads from XNat (remoote XNat Central server): we can handle at least 6 cases (4 CT scans in each) per hour, which is compatible with current workload quotes on SPL cluster processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* December 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Deployed Version 1. &amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Test project chosen as a closest match to registration scenario: Pediatric MS Cases from MGH - requires periodic image preview for different &lt;br /&gt;
modalities taken from vaious time points. Label maps for VOIs resampling is also required.&lt;br /&gt;
&lt;br /&gt;
* November 26, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user. Version 1 is complete&amp;lt;br&amp;gt;&lt;br /&gt;
* Started working on integration with XNat&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on input data organizing modules&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 19, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user (70% done)&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Universal Registration Workflow for Longitudinal Studies - design specs in progress&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 12, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Minor tuning to EM Segmentation template as of users' feedback&lt;br /&gt;
* Users started using the workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed input data conversion from Genesis to Slicer native or NIFTI format. Our help may be needed in input data organizing.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Tuned application according to co-laborators (PNL) needs&amp;lt;br&amp;gt;&lt;br /&gt;
* The webservices and BPEL workflow application are tested ready to accept computation requests from PNL case tracking system &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Discussed Universal Registration Workflow for Longitudinal Studies&lt;br /&gt;
* Started the thread about possible cooperation with Children hospital's image processing pipelines and integration with Xnat &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 5, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Webservices and workflow pilot project created and deployed on Psychiatry Neuroimaging Laboratory subnet &amp;lt;br&amp;gt;&lt;br /&gt;
* The V.1.0 deployment is scheduled for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 29, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Most of functionality is completed. Some volume statistics post processing is pending&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL EM SEGMENTATION Pipeline: &amp;lt;br&amp;gt;&lt;br /&gt;
* The SPECTRE scull stripping module. Started integration into EMS workflow. Made some test runs from Slicer GUI&amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Identified as a candidate for Workflow Application&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 22, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* All back-end functionality are implemented&amp;lt;br&amp;gt;&lt;br /&gt;
* EM Segmentation scene usability is confirmed by end-user&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for next week: add Label Statistics computation for CSF/Brain/ICC &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 15, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* The latest (October) builds of Slicer 3.6.2 produced acceptable results. This was verified by the target users. The EM Segmentation will be performed on Slicer 3.6.2 or later&amp;lt;br&amp;gt;&lt;br /&gt;
* The new Web services had been created and added to the pipeline as optional processing steps: Biasfield correction (implement novel N2ITKBiasFieldCorrection module) and Volume's scalar datatype casting (as workaround for Biasfield correction module not preserving image scalar datatype - the bug is filed) &amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed the Front-End GUI design with target users. The design pattern is taken from the PETCT project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 8, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-deployment support. Tuned CT registration as of user's feedback.&lt;br /&gt;
* Adapting to the Single Slicer build: Slicer 3.6.2. Found label duplicates in the label lookup table - will ask user if it's tolerable. Waiting for the Slicer 3.6.2 build that contains all required modules. Rolling back label tag appending code for SUVs - the latest Slicer build appends the tags.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Resumed development. The priorities are set for usage of Slicer 3.6.2 - subject for EM Segmentation scene tuning. Continued coding for Scene creation for Slicer 2.8 - as a backup option for ongoing research project.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 1, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized V1.0 release based on end-user feedback: updates relate mostly to error proofing and SUV values representation&lt;br /&gt;
* Post-deployment support. Users pre-processed first set of patients &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* September 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* System deployed and tested at End Users' site.&amp;lt;br&amp;gt;Users are trained to perform all tasks required by the workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
* Got positive feedback with suggestions on Slicer Scenes' layouts improvement and PET scans' SUV (standard uptake values) results display&lt;br /&gt;
* Two distribution packages are assembled: Lunix and MAC OS versions. The difference in two packages is in specific Slicer3.6/3.7 builds - subject to Slicer Linux builds debugging.&amp;lt;br&amp;gt; As a workaround for Linux deployment - multiple Slicer builds are used to perform various tasks (registration, opening editing scenes in Slicer, SUV computing)&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for coming week - finalize V1.0 release based on end-user feedback&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Embedded SUV computations into the workflow (as system calls - will be translated into web service later)&amp;lt;br&amp;gt;&lt;br /&gt;
* Pre-release demo for end users.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Create and debug EM Segmenter scenes template for Slicer 3.6 and 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* September 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation - workflow pipeline and deployment verified&amp;lt;br&amp;gt;&lt;br /&gt;
* Tested EM Segmentation scenes within Slicer 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
* Started migration of EM Segmentation to Slicer 3.6. Discovered issues had been reported to EM Segmenter module designers &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* August 29 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation completed. Preprocessing Pipleine completed 80% (subject for input registration parameters tuning) &amp;lt;br&amp;gt;&lt;br /&gt;
* Most webservices (for registration and resampling steps) had been taken and re-used from PET/CT ROI/Longitudinal Study - showing the advantage of service-oriented software design and deployment.&lt;br /&gt;
* Continued on distribution and deployment of the service/workflow applications: on PET/CT and AGING STUDY projects.&lt;br /&gt;
&lt;br /&gt;
PEDIATRIC Multiple Sclerosis Cohort. Support of multi-center distributed processing project&amp;lt;br&amp;gt;&lt;br /&gt;
* Introduced Slicer 3.6 for the MS Lesion Assessment step performed at Mayo Clinic. Images are being transferred from image repository at BWH and automatically opened and arranged within Slicer GUI for reading.  This was replacement of Client GUI using MIPAV that stopped working on new computers at Mayo Clinic.&lt;br /&gt;
The images are being loaded via generated MRML Scenes same way as in PET/CT and AGING STUDY projects &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* August 22 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Preprocessing pipeline merge with SUV computations &amp;lt;br&amp;gt;&lt;br /&gt;
- QA for SUVs computation was performed by Wendy Plesniak for images with known uptake values. &amp;lt;br&amp;gt;&lt;br /&gt;
- Discovered that image cropping step (not related to automated registration pipeline and SUVs computing) smoothes the images by doing interpolation when used with default settings. Got suggestions from Steve Piper using Nearest-Neighbor interpolation (&amp;quot;no interpolation&amp;quot;) for a time being&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
- This is the new project candidate. Requested for the images with failed manual segmentation and/or segmentation with FreeSurfer. The EM Segmentation run showed most acceptable results on one of the problem images back in February &amp;lt;br&amp;gt;&lt;br /&gt;
- The workflow will be developed and deployed similar to PET/CT ROI Longitudinal study approach - all preprocessing steps will be done with Slicer modules, all runs will be performed on local end-user machines.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
 &lt;br /&gt;
&lt;br /&gt;
* August 15 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- First 5 cases with 3-4 time points preprocessed for SUVs computation&lt;br /&gt;
&lt;br /&gt;
* August 8 2010&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Testing of installation and operation at users' site (Performed by Wendy Plesniak)&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* July 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Delivered beta version of registration pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
- Prepared installation and user manuals &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* June 11, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Registration modules completed &amp;lt;br&amp;gt;&lt;br /&gt;
- Irregular cases registration problem solved (when whole body and brain only scans are mixed for a timepoint)&amp;lt;br&amp;gt;&lt;br /&gt;
- Live demo of case setup and registration workflow for end users. Real case with 4 timepoints used&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Coming week plans&amp;lt;br&amp;gt;&lt;br /&gt;
- Adjust workflow based on end users' feedback&amp;lt;br&amp;gt;&lt;br /&gt;
- Integration with SUVs computing for PET scans&amp;lt;br&amp;gt;&lt;br /&gt;
- GUI for workflows dispatching and data organizing&amp;lt;br&amp;gt;&lt;br /&gt;
- (TBD) Integration with 4D time series analysis Slicer module&amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
* May 28, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- Migration to the latest Slicer 3.6 release candidate &amp;lt;br&amp;gt;&lt;br /&gt;
- Added webservice for new registration module: BRAINSFit &amp;lt;br&amp;gt;&lt;br /&gt;
- Test runs for new patients with 4 timepoints' scans &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Plans for next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI &amp;lt;br&amp;gt;&lt;br /&gt;
- processing workflow demo for end user &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 21, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Pilot version of portable web services and automated workflow tested: &amp;lt;br&amp;gt;&lt;br /&gt;
Linux: workflow and visual review passed&amp;lt;br&amp;gt;&lt;br /&gt;
Stress test for 25 timepoints passed &amp;lt;br&amp;gt;&lt;br /&gt;
MAC OS: workflow passed, visual review failing when PET/CT images are loaded into GUI simultaneously (bug report submitted)&amp;lt;br&amp;gt;&lt;br /&gt;
Windows: need to adapt command line modules and workflow management system to sygwin environment&amp;lt;br&amp;gt;&lt;br /&gt;
Plans for next week: integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI&lt;br /&gt;
&lt;br /&gt;
* May 7, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Selected registration and resampling modules with more precise and stable outputs. &amp;lt;br&amp;gt;&lt;br /&gt;
Started building portable web services and automated workflow &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 30, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- manual walk through the processing steps: ROI cropping, registration/resampling, PET pharmaceutical DICOM data retention. &amp;lt;br&amp;gt;&lt;br /&gt;
- testing workflow and web services packages distribution to end-users' machines&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* April 23, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : testing various registration and re-sampling algorithms (work in progress)&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation: as of collaborators' request, run existing EM Segmentation workflow for older low resolution pseudo-T1 images. The EM Segmentation works for those images with manual sampling. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 16, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
  Social Cognition Study: started Cortical Thickness Measurement module build (bases on NA-MIC ARCTIC pipeline) &amp;lt;br&amp;gt;&lt;br /&gt;
  PET/CT ROI/Longitudinal Study Registration : Design specs, PET-to-CT images registration tests on training data. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 9, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. GUI update based on end-user experience.&amp;lt;br&amp;gt;&lt;br /&gt;
User request: automated label maps' volumes calculation (Currently possible from Slicer3 GUI)&amp;lt;br&amp;gt; &lt;br /&gt;
PET/CT ROI Project. Initial design specs discussion with end-users and co-developers&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure&lt;br /&gt;
Verification of segmentation workflow GUI: from registering new case to reviewing results&amp;lt;br&amp;gt;&lt;br /&gt;
Cross study test of segmentation workflow: MGH/MS Center data - success,  HIV Project data - some EM Segmentation scene tuning is needed &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*&lt;br /&gt;
* April 2, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. Segmentation workflow completed&amp;lt;br&amp;gt;&lt;br /&gt;
* Coming Week plans:&amp;lt;br&amp;gt;&lt;br /&gt;
- Document Segmentation Workflow. Follow up with end users &amp;lt;br&amp;gt;&lt;br /&gt;
- Start with Cortical Thickness and ROI-in-longitudinal studies workflows&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* March 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All essential processing and workflow interaction clients are ready.&amp;lt;br&amp;gt;&lt;br /&gt;
- Completed segmentation for 10 out of 50 patients. The remaining cases will be finalized upon manual lesion segmentation and QC verification of WM/GM/CSF and Deep GM segmentation's. &amp;lt;br&amp;gt;&lt;br /&gt;
- TODO next week: refine QC GUI and data tracking / progress monitoring schema. &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&amp;lt;br&amp;gt;&lt;br /&gt;
- New Slicer3 web services added: re-slicing with reference image volume, casting image scalar type &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
* March 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Segmentation maps Merging Services for GM/WM/CSF (Slicer EM Segemnter), Lesion (Slicer, Manual), and Deep GM (FreeSurfer)  &amp;lt;br&amp;gt;&lt;br /&gt;
- Deep GM segmentation pipeline adopted as optional service for Social Cognition Study (22 out of 50 cases processed) &amp;lt;br&amp;gt;&lt;br /&gt;
- (In progress) GUI client for Launching Segmentation results merging with optional Deep GM segmentation with FreeSurfer &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- Complete GUI Client for Segmentation result merging &amp;lt;br&amp;gt;&lt;br /&gt;
- Progress Monitoring services for entire Study processing: EM Segmenter Preprocessing, EM Segmentation, Lesion Segmentation (including human activities assignments), Deep GM segmentation, and results consolidation. &amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* March 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All 50 cases went through &amp;quot;basic&amp;quot; One-channel EM segmentation (GM/WM/CSF) &amp;lt;br&amp;gt;&lt;br /&gt;
- Basic pipeline start-up command line client created: user has two options - request brainmask extraction or provide with previously extracted brainmask for a given subject &amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison of GM/WN/CSF performed for Slicer EM Segmenter and FreeSurfer recon-all (used with default settings). &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmenter provides more accurate output &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmentation pipeline runs faster (40 minutes vs 12 hrs when no brainmask extraction requested) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO:&amp;lt;br&amp;gt;&lt;br /&gt;
- merging modules for automatic 1-channel EM segmentation and manual lesion segmentation &amp;lt;br&amp;gt;&lt;br /&gt;
- Emerge Cortical Thickness pipeline project: use NAC ARCTIC processing steps and modules &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Selected stable EM Segmentation scenario: White Matter, Gray Matter, and Cerebrospinal Fluid &amp;lt;br&amp;gt;&lt;br /&gt;
- First 16 cases are segmented for selected scenario. Nine more cases are preprocessed for EM Segmentation.&amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison to segmentation with FreeSurfer showed better accuracy for Slicer2 EMSegmenter &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure &amp;lt;br&amp;gt;&lt;br /&gt;
- Three prerpcocessed cases failed during volume ICC masking with in-house build utility. Evaluated switching to Slicer3 Mask and island removing modules.&amp;lt;br&amp;gt;&lt;br /&gt;
- Initial design specs discussion for cortical thickness measurement pipeline. ARCTIC pipeline selected. ARCTIC preprocessing steps signifficantly overlap with EM Segmentation preprocessing workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
  &lt;br /&gt;
* February 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: &amp;lt;br&amp;gt;&lt;br /&gt;
A) parameters tuning for EM Segmenter itself (work with EM Segmenter developer), template scenes creation &amp;lt;br&amp;gt;&lt;br /&gt;
B) update preprocessing pipeline - deep gray matter atlases included &amp;lt;br&amp;gt;&lt;br /&gt;
C) test and debug preprocesing pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
D) identified missing modules: atlas autocalibration for EM Segmentation scene, Island removal for ICC mask&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- Review currently deployed modules. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: reviewed firts seven subjects' outputs, added volume orientation module into pipeline (prevents ICBM atlas linear registration failures)&amp;lt;br&amp;gt;&lt;br /&gt;
- Fused ICC(brainmask) extraction module with EM Segmenter preprocessing. Three scenarious implemented: start with pre-extracted ICC mask (longitudinal studies case), run with ICC ectration, run with ICC extraction AND ICC correction before ICBM atlas preporcessing. &amp;lt;br&amp;gt;&lt;br /&gt;
- Completion of Human activities GUI (QC, ICC Correction) planned for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: Volume Orientation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: automated preprocessing pipeline for Slicer2 EM Segmenter test version deployed. Seven cases pre-processed.&lt;br /&gt;
- PET Quantitative measurements: Preliminary design specs discussion.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: BSplineRegistration (for non-linear registration), ResampleVolume2 (for atlases resampling based on image atlase templates registration). Local and Network runs are implemented, Cluster/GridWizard implementation pending.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Slicer EM Segmenter module: preprocessing design for Slicer2 EM Segmenter&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Adapting for Slicer2 EM Segmenter (mostly from pipelines and services for previous projects)&lt;br /&gt;
  -- Integration with FreeSurfer modules for bisafield correction, brainmask extraction, and linear registration of ICBM atlases&lt;br /&gt;
  -- Preprocessing updates for non-linear registration of ICBM atlases with Slicer2 (image re-orientation service designed)&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 29, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- EM Segmentaton pipeline: preprocessing results are being transferred to XNat (anonymized data, Central XNat) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Slicer EM Segmenter module: discussed agenda and scheduled a work meeting for Social Cognition Study image segmentation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Testing stage, 95% completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- SPL XNat server: verified data exchange via RESTfull web services.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 22, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Follow up with White Matter Lesion Segmenter and Scull Stripping Modules developers: Work in Progress&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Work in Progress, 60%+ completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Discussed SPINE image repository migration to XNat&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 15, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. &lt;br /&gt;
- Social Cognition Study: &lt;br /&gt;
Work-in-progress on intermediate (reconstruction) and results (resources) data storage at XNat.&lt;br /&gt;
&amp;lt;br&amp;gt;Reviewing and preparation more cases for EM Segmentor (Slicer 3.5) tuning.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* NA-MIC Project Week&lt;br /&gt;
Selecting candidate Slicer modules for other than Lesion EM Segmentation topics of Social Cognition study: Withe Matter Lesion Segmenter (UNC), Scull Stripping utility from UIOWA.&lt;br /&gt;
Reviewing issues of currently used Scull Stripping Slicer Extension and Slicer 3.5 EM Segmenter.&lt;br /&gt;
&amp;lt;br&amp;gt;XNat Data organizing training&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 1, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Preparation of Demo for NA-MIC work week: &lt;br /&gt;
- COPD Study. Added Remote pipepline start interface (represents real world scenario where Xnat repository, Processing modules and User are at different sites)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
- EM Segmentation. Added human activities steps to the workflow: ICC (brainmask) correction and EM Segmantation scena load per se.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 25, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Pilot workflow pipeline for EM Segmentation (all steps except user-activity step: ICC correction assignment and tracking)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 18, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Build and tested web services for EM Segmentation image preprocessing: DICOM-to-NRRD conversion, registration, skull stripping, image masking.&lt;br /&gt;
Started building workflow pipeline (subject to finish first version next week)&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Started Collecting Library of Slicer Build number vs. functional modules and extensions.&lt;br /&gt;
Plan for NAMIC project week: scheduled meetings for XNat data customization, Skull-stripping modules tuning, identified Social Cognition study cases that fail EM Segmentation processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 11, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Updating and verification of EM Segmentation Scenario&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Projects:ARRA:SlicerWF:UseCaseScenarios#Usecase_MS_lesion_Assessment&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Familiarizing with Slicer3.4/5 Modules required for implementation of EM Segmentation Scenario. Participation in debugging and/or usage tuning of Dicom Conversion, Registration, Skull Stripping, Masking, and Image Casting modules. &lt;br /&gt;
&lt;br /&gt;
* December 4, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Slicer3.4's EM Segmentation and Visual QC as part of image processing pipeline for Social Cognition Study for MS Patients.&lt;br /&gt;
Project emerged. EM Segmentation template creation debugged.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
Emphysema Measurements (COPD Study) - workflow stability and scalability test.&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 27, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Emphysema Measurements (COPD Study).&lt;br /&gt;
Added compensation for long running calculations and time-outs to the main computing pipeline.&lt;br /&gt;
Visual QC (work in progress)&lt;br /&gt;
** Infrastructure&lt;br /&gt;
XNat data structure customization, metadata storage, results consolidation: new feature request list creation (work in progress)&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 13, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
*** Pilot system for whole processing cycle for Emphysema Measurements (COPD Study) including the following:&lt;br /&gt;
Web query for CT session file list download&lt;br /&gt;
Pilot user interface for submitting the file list and starting processing pipeline&lt;br /&gt;
Notification about processing steps and failures&lt;br /&gt;
Upload results to XNat repository (at this stage results are uploaded into same folder where original scans are(*))&lt;br /&gt;
*** Immediate Plans&lt;br /&gt;
Complete Visual QC module&lt;br /&gt;
Design and implement meta-data transfer to XNat (including processing details and MRML files for loading images into the 3D Slicer)&lt;br /&gt;
&lt;br /&gt;
(*)Customization of results storage&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 6, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Tuned and debugged multiple subjects processing for: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat.&lt;br /&gt;
***Started working on quality control embedding into the above scenario. Plan to complete and video-record demo next week.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***Published general Product Integration scenario flow chart to collaborators' community. Discussion is open and in progress&lt;br /&gt;
&lt;br /&gt;
* October 30, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Piloted and tested the sequence: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat(1).&lt;br /&gt;
***Performance test of overall cycle: data transfer from remote serve is a bottleneck as expected&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data browsing features reviewed.&lt;br /&gt;
(1) Not automated yet&lt;br /&gt;
* October 23, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Defined COPD processing scenario with interoperability between Xnat, 3D Slicer Command Modules, Workflow, and Gridwizard Enterprise.&lt;br /&gt;
***Pilot version of Emphysema Measurements workflow pipeline deployed.&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data transfer features reviewed. Use account at XNat Central during learning curve.&lt;br /&gt;
***Feasibility test of 3D Slicer fiducials module for ROI highlights during QC and manual image processing activities. &lt;br /&gt;
* October 16, 2009&lt;br /&gt;
**Lung CT Scans Processing. Pilot project emerged. GenerateEmphysemaMeasurements module deployed as a webservice that submits jobs to computational cluster.&lt;br /&gt;
**EM Segmentation. Familiarized with GUI steps. Started working on automation steps outlining&lt;br /&gt;
**3D Slicer and XNat interaction. Got an overview from Wendy Plesniak.&lt;br /&gt;
* October 1 - 7, 2009&lt;br /&gt;
**Selected two first priority Projects: EM Segmentation of brain MRI images; Lung CT Scans Processing (COPD Study)&lt;br /&gt;
**Got initial outline of user requirements and design specs&lt;/div&gt;</summary>
		<author><name>Azaitsev</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=70655</id>
		<title>Projects:ARRA:SlicerWF</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=70655"/>
		<updated>2011-08-29T19:01:48Z</updated>

		<summary type="html">&lt;p&gt;Azaitsev: /* Progress */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Projects:ARRASuplements|Back to Slicer ARRA home page]]&lt;br /&gt;
= Aim =&lt;br /&gt;
Supplement 3D Slicer and Extensible Neuroimaging Archive Toolkit (XNAT) with workflow management system. Provide integration and interoperability between 3D Slicer, XNAT Services and 3-rd party image processing applications and high performance computing systems. Implement it as within currently developed Structural Planning and Implementation in Neurological Exploration (SPINE) System.&lt;br /&gt;
&lt;br /&gt;
= SPINE Project Documentation =&lt;br /&gt;
[http://cni.bwh.harvard.edu/projects/spine/index.html SPINE Docs]&lt;br /&gt;
&lt;br /&gt;
= Presentations =&lt;br /&gt;
* Segmentation Workflow. PECS University Social Cognition Study.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:SlicerWF_NAC_PECS_Workflow.pdf]]&lt;br /&gt;
* EAB10_ARRA Annual Progress Report Slides.&amp;lt;br&amp;gt;&lt;br /&gt;
[[media:EAB10_ARRA_WF_2011_Zaitsev.ppt | Service Oriented Solutions for 3D Slicer. EAB10_ARRA_WF_2011. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:EAB10_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:NAMIC_ARRA_WF_2011_Zaitsev.ppt  | NAMIC Annual Report 04/2010-03/2011. NAMIC_ARRA_WF_2011_Zaitsev. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:NAMIC_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:Slicer_WF_Slicer4CARMAWorkflow.ppt  | CARMA Workflow. Cardiac Ablation Followup. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:Slicer_WF_Slicer4CARMAWorkflow.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* CARMA Project Beta release Demo Location: http://cni29.bwh.harvard.edu/SlicerWFDemo/index.php&lt;br /&gt;
&lt;br /&gt;
* Segmentation Workflows: Screenshots, scans' and study description : [[File:SlicerWF_EMSegmentProjectsReview.zip]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
= All Hands Meeting Pages =&lt;br /&gt;
* MIT 2011 Summer:&lt;br /&gt;
 Workflows Project [http://www.na-mic.org/Wiki/index.php/Summer_project_week_2011_Workflows_SOA MIT_2011_WorkFlow]&lt;br /&gt;
 Segmentation Project (MS Lesions)[http://www.na-mic.org/Wiki/index.php/2011_Summer_Project_Week_Customizing_EMSegmenter_pipelines_for_brain_lesions MIT_2011_LesionsSegmentation]&lt;br /&gt;
* Salt Lake City 2011 Winter [http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA SLC_2011_WorkFlow]&lt;br /&gt;
* MIT 2010 Summer [http://wiki.na-mic.org/Wiki/index.php/Summer_project_week_2010_Workflows_SOA MIT_2010_WorkFlow]&lt;br /&gt;
&lt;br /&gt;
= Research Plan =&lt;br /&gt;
*Create a stand-alone SPINE desktop agent with fully functional data exchange and communication mechanisms towards 3D Slicer and XNAT.&lt;br /&gt;
*Develop Service Oriented Architecture (SOA) SPINE System that will include 3D Slicer image processing modules deployed as web services as well as a workflow management system to orchestrate interaction between 3D Slicer, XNAT, and 3-rd party tools.&lt;br /&gt;
*Implement two-way control and communications between 3D Slicer and SPINE modules.&lt;br /&gt;
*Adapt SPINE System for cluster and grid computing scenarios.&lt;br /&gt;
*Provide with workflow and 3D Slicer web service wrappers editing tools.&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:UseCaseScenarios| Use Case scenarios]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PETCTWorkflow| PETCTWorkflow]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:AgingStudySegmentation| AgingStudySegmentation]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:TwoTensorTractography| TwoTensorTractography]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:LongitudinalMultimodalityRegistrationSuite| LongitudinalMultimodalityRegistrationSuite]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:MigrationJavaClients2QT| MigrationJavaClients2QT]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PediatricMSSegmentation| PediatricMSSegmentation]]&lt;br /&gt;
*[[DBP3:Utah:RegSegPipeline| MRI-based study and treatment of atrial fibrillation]]&lt;br /&gt;
&lt;br /&gt;
= Application Server / Workflow Engine Downloads =&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:WFEngineDownloads| Download Links]]&lt;br /&gt;
&lt;br /&gt;
=Key Personnel=&lt;br /&gt;
* Charles Gutmann, MD., 4%,  9-17-2009 through 9-16-2011&lt;br /&gt;
* Alexander Zaitsev, Ph.D., 75%, 9-17-2009 through 9-16-2011 &lt;br /&gt;
&lt;br /&gt;
=Annual Progress Statements =&lt;br /&gt;
'''2010-11''' &amp;lt;br&amp;gt;&lt;br /&gt;
The  April 2011 – March 2011 period was devoted on developing portable workflow solutions that can be deployed on end-users' workstations or notebooks with minimal or no system administration activities. This is in contrast to the server-side deployment. The following scenarios had been deployed and used for actual projects that require the following types of workflows: PET/CT registration and computation of biomarker driven brain physiological activities, Brain MRI Images segmentation,  MRI and MRI Angiography images pre-processing for cardiac ablation outcome estimation. Some  workflows (like EM Segmentation) had been utilizing various scenarios, some research projects  (like evaluation of chemotherapy outcome) require two types of workflows to assess physiological and structural changes. Starting from the 4th Quarter of 2011, the migration project had been emerged in order to embed Workflow GUIs into newly developed Slicer4 Suite. The existing rich client Java GUI applications are being re-written as C++/QT Sliceletts units, new modules (such as cardiac ablation project support) are had been written from scratch. The latter are being deployed from the Slicer4 GUI and act at a liaison between Slicer4 and Application Server containing  workflow and Slicer modules deployed as services. The feedback from the end users indicates that Workflow approach for the complex processing improves productivity, aids to the processing standardization and contributes to the overall experience using 3D Slicer&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
=Quarterly Progress=&lt;br /&gt;
&lt;br /&gt;
* '''2d Qtr, 2011''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study: Second release deployed. &lt;br /&gt;
*** End-users completed the first Project and currently analyzing SUV values and clinical data&lt;br /&gt;
*** New features added: Human Brain Hemispheres segmentation, Scull-stripping for total SUV counts calculation, Flexibility of custom designed label look-up table usage (users can define ROI notation according to the Project needs)&lt;br /&gt;
&lt;br /&gt;
** Left Atrium Ablation Assessment (CARMA Project)&lt;br /&gt;
*** Completed workflow pipeline for automated pre-processing and manual intervention&lt;br /&gt;
*** Developed front-end GUI for the CARMA Project support in Slicer4.&lt;br /&gt;
*** Run the workflow with the end users during NAMIC Project Week&lt;br /&gt;
*** Evaluated feasibility of left atrium wall and post-ablation scar segmentation using Robust Statistical Segmentation (RSS). Identified necessary processing controls with RSS module designers&lt;br /&gt;
&lt;br /&gt;
** Multiple Sclerosis CLIMB Study&lt;br /&gt;
*** Reprocessing for lesion segmentation&lt;br /&gt;
*** Developed Web-based (Java EE 6) application for submitting cases to the workflows for EM Segmentation of MPRAGE and registration to PD/T2/FLAIR images (60% completion)&lt;br /&gt;
&lt;br /&gt;
** EM Segmentation: &lt;br /&gt;
*** Upgraded EM Segmentation services to Slicer 3.6.4&lt;br /&gt;
*** Added brain hemispheres segmentation module to the workflows (used for PET/CT Longitudinal study)&lt;br /&gt;
*** Work with EM Segmenter module developers on building pipelines for white matter lesion segmentation (work in progress)&lt;br /&gt;
&lt;br /&gt;
** Plans for the 3rd quarter&lt;br /&gt;
*** Migrate CARMA Project workflow to end-users&lt;br /&gt;
*** Packaging of Slicer4 Workflow modules and Slicer4 custom build distribution &lt;br /&gt;
*** Completion of Web-base segmentation and registration suite&lt;br /&gt;
*** Users and Developers Documentation&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* NAMIC Annual Progress Slides (April 2010 - March 2011):&lt;br /&gt;
&lt;br /&gt;
* '''1st Qtr, 2011''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study: Second release is under testing by end-users. &lt;br /&gt;
*** Added MRI registration to aid ROI drawing on PET scans&lt;br /&gt;
*** Improved SUV results reporting and added flexibility to update ROI lookup table&lt;br /&gt;
*** Automated EM Segmentation of MRI images for computing SUVs for white matter, CSF, and whole brain (80% completion)&lt;br /&gt;
*** Integration with SPECTRE scull stripping module (70% completion) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** EM Segmentation: Automated WF Pipelines are created &amp;lt;br&amp;gt;&lt;br /&gt;
*** Flexible atlas selection (Pediatric, etc) feature added&lt;br /&gt;
*** Workflows implemented for EM Segmenter 3.6.2 and 3.6.3 (1st Qtr 2011 release)&lt;br /&gt;
&lt;br /&gt;
** Cardiac ablation results follow-up: Workflow for registration and ROI selection of cardiac MRI and MR Angiography &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Wrokflow and Web Services for prospective DTI tractography modules (currently written as Matlab modules at PNL) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Web Services for SPECTRE Scull stripping module&lt;br /&gt;
*** Accuracy and performance tuning&lt;br /&gt;
*** 50% completion&lt;br /&gt;
&lt;br /&gt;
** Migration Front End GUI to Slicer4/QT:&lt;br /&gt;
*** EM Segmentation&lt;br /&gt;
*** Cardiac Ablation Study&lt;br /&gt;
&lt;br /&gt;
** DICOM Uploader and Desktop Browser for XNat Image repository (alpha version - tested for MGH MS Center studies, proposed to use with MI2B2 Clients and Services)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''4th Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study and EM Segmentation for Aging Study are deployed at end-user sites and actively used for research. &lt;br /&gt;
** Adopted EM Segmentation preprocessing pipeline for HIV Study: high resolution SPGR images, integration with FreeSurfer brainmask extraction outputs; integration of Slicer SPECTRE module for brainmask extraction is in progress.&lt;br /&gt;
** The following post-release upgrades had been implemented based on end-user feedback: Application Server basic controls are performed from Rich Client GUI as alternative to traditional IT administration activities. The controls are implemented on point-and-click bases and include web services and workflow application deployment and upgrades, application server start and stop as well as warning end user when the server is not accepting request.&lt;br /&gt;
** Added DICOM downloads and results uploads of PET/CT pipelines from and to XNat Repository&lt;br /&gt;
** Created Services and Workflow for Matlab Prototypes modules. Case Study: tractography for DTI images&lt;br /&gt;
** Extended XNAT integration services:&lt;br /&gt;
*** Browsing capabilities of XNat data repository from the Workflow Applications&lt;br /&gt;
*** Improved DICOM upload and download performance&lt;br /&gt;
*** Added Metadata organizing services for uploaded DICOM images: header data extraction, image snapshots creation. &lt;br /&gt;
** Started project for Rich Client GUI migration from Java desktop application to build into SLicer4 QT modules. This affects mostly front-end GUI and has the following approaches: distribution with the Slicer4, end-user will select desired workflow application from Slicer4 menu while QT-written modules provide with the same functionality as Java Rich Clients. Case Study for the Migration process: registration suite for longitudinal studies that include multi-modality images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* '''3d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Concentrated on building downloadable workflow applications that could run both in desktop (new) and server environment, and that require minimum IT administrative resources. The desktop deployment is in compliance with Slicer3 general deployment concept.&lt;br /&gt;
*** The following use case scenario had been chosen: PET/CT image processing for longitudinal studies, EM Segmentation for longitudinal Aging Study.&lt;br /&gt;
** Released workflow application for PET/CT image processing for longitudinal studies. Provided end users with training and documentation.&lt;br /&gt;
*** The PET/CT processing workflow was designed to be a general application used whenever both structural patterns and metabolic activities are within the research scope. &lt;br /&gt;
*** The desktop version is tuned to use minimal computer resources, so the automates processing instances do not interfere with human activities. Automated activities may include, for example, registration and PET scan's standard uptake values computing, and manual human activities may include image cropping, quality control, and labeling voxels of interest.&lt;br /&gt;
** Core services and EM Segmentation preprocessing workflow was build for retrospective Aging Study. Tuned the Slicer3 webservices for processing low grade images acquired in mid 90s. Entire workflow is implemented with Slicer3 only modules and can be deployed locally and on the servers. Usage of Service Oriented Architecture (SOA) as a core technological approach allowed reusing most of the web services that had been build for PET/CT project. &lt;br /&gt;
** Continued embedding Slicer3 application and modules into previously released processing pipelines: replaced MIPAV with Slicer3 GUI for lesion assessment step in the multi-center Pediatric MS Cohort image processing &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''2d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Completed Social Cognition Workflow Implementation. This includes EM Segmetnation pre- and post-processing pipelines, data tracking, and integration with 3d party image processing utilities, as well as processing results acquired manually with Slicer GUI.  &lt;br /&gt;
** Multi-modality image registration and ROI selection/alignment workflow for longitudinal studies. &lt;br /&gt;
*** Use case: PET/CT image processing for longitudinal studies. &lt;br /&gt;
*** Build portable library of Slicer modules as web services and workflow that are deployed and run on a end-users' worksatations without utilization of SPL and other servers. The web services include novel Slicer3 modules, such as BRAINSFit and BRAINSResamle &lt;br /&gt;
*** Started working with Slicer3 developers on Slicer 3.8 GUI wizard to communicate with workflow instances.&lt;br /&gt;
** Participated at NA-MIC Summer 2010 Project Week: [[Summer_project_week_2010_Workflows_SOA]]&lt;br /&gt;
&lt;br /&gt;
=Progress=&lt;br /&gt;
* August 26, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project:&lt;br /&gt;
* Packaging on Max OS X 64-bit: troubleshooting QT 4.6 (build tree) QT 4.7 (make package) conflicts&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
3D Slicer WF. General&lt;br /&gt;
* 3D Slicer and WF Modules presentation at MGH Radiation Oncology&lt;br /&gt;
&amp;lt;br&amp;gt;  &lt;br /&gt;
&lt;br /&gt;
* August 19, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation&lt;br /&gt;
* Deployed first release (Human Brain EM Segmentation) web request application&lt;br /&gt;
* End-users requested EM Segmentation of MS lesion on PD images (feasibility is being evaluated with EM Segmenter Team)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
3D Slicer WF. General&lt;br /&gt;
* Preparation of 3D Slicer and WF Modules presentation for MGH&lt;br /&gt;
&amp;lt;br&amp;gt;  &lt;br /&gt;
&lt;br /&gt;
* August 12, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
* Migrating build to updated Slicer4 environment  (PythonQT and new added module dependencies issues)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation&lt;br /&gt;
* Tested and reviewed EM Segmentation web app on end-users' data&lt;br /&gt;
* Updated workflow, so EM Segmentation is performed on T1 after registration to T2 or FLAIR. This gives more accurate results comparing to segmentation of high resolution image followed by resampling (have to use nearest neighbor interpolation to retain actual label values) of label map &lt;br /&gt;
&lt;br /&gt;
* August 5, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT&lt;br /&gt;
* Follow-up with end users with new Study setup&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
CARMA Project&lt;br /&gt;
* Documentation (Work in progress)&lt;br /&gt;
* Plans for next week: custom packaging (Mac Snow Leopard 64 bit), building extension, documentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation&lt;br /&gt;
* Stress-test of online segmentation requests suite for  [http://www.slicer.org/slicerWiki/index.php/EMSegmenter-Tasks#Additional_Use_Cases CLIMB Study](for BWH MS Center)&lt;br /&gt;
* Reason for building online suite: the Group is Using mostly MAC OS Tiger machines for legacy reasnos, the most recent Slicer3 builds as well as QT don't work on those machines (QT4.x runtime could not be installed).&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* July 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA Project&lt;br /&gt;
* Documentation (Work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation&lt;br /&gt;
* Work on alpha-release of online submission of segmentation requests (for BWH MS Center)&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* July 22, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
Vacation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* July 8, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
3D Slicer in General and CARMA Project&lt;br /&gt;
* Presentation and life demo at Cardiology Research Center (Moscow, Russia) [[File:RussianCardiologyCenterCARMA2011.ppt]]&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* July 1, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA V1.0&lt;br /&gt;
* Migration to new QT building environment (Mac 10 Snow Leopard). &lt;br /&gt;
* Building custom package. Issues: new features (not only WF related) are not shown on the menu of the resulting application&lt;br /&gt;
* Comparing preprocessing workflow results with published in literature data (our module produces better alignment)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*June 24, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
Project Week:&lt;br /&gt;
* Testing RSS module for left atrial wall scar segmentation&lt;br /&gt;
* Testing EM Segmenter for lesion detection on PD (requested by end-users) and FLAIR images&lt;br /&gt;
&lt;br /&gt;
EM Segmentation &lt;br /&gt;
* Web-based segmentation and registration module for MS Center. Goal: facilitate 3D SLicer modules for the cases that could not be processed with in-house build DTS+ algorithm&lt;br /&gt;
* Pipeline: Segment MPGR or T1 (user's choice), Register MPGR to PD/T2, Resample Segmentation Map to PD/T2. Completion: 60-70%.&lt;br /&gt;
* The rest will be done manually or via lesion segmentation with EM Segmenter.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* June 17, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
Preparation for Project Week&lt;br /&gt;
&lt;br /&gt;
* June 10, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
CARMA V.1.0&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code completed and tested&lt;br /&gt;
* Packaging as extension is pending (Subject for Summer 2011 Project week)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Debugging consolidation results issue(SUVs for manual and automated segmentation) &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* June 3, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Deployed on end-user's machine&lt;br /&gt;
* TODO next week: fix SUV results consolidation issue (when MRI segmented ROI got SUV computed for some subjects, only those subjects' SUVs are being added into consolidated report. &amp;quot;Raw&amp;quot; SUV values per subject are generated as expected)  &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 27, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Ready for deployment. New Features: hemispheres EM Segmentation, automated ICC/brainmask extraction using EM Segmenter, fixed controls for MRI conversion and registration&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 20, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General / PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Hemispheres EM Segmentation - adjusted for required label lookup table&lt;br /&gt;
* Use cases added for EM Segmenter General Project: http://www.slicer.org/slicerWiki/index.php/EMSegmenter-Tasks#EMSegmenter_use_cases&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SPECTRE Scull Stripping&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* The new version to be tested on coming week (After PETCT MRI processing migrated to Hemispheres scenario )&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* May 13, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General / PETCT V1.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Hemispheres EM Segmentation - technically works with labal values hardcoded in Slicer EM Segmenter - need to add manual label value edition step&lt;br /&gt;
* PETCT WF Cut for Java GUI (Pending Hemispheres label update completion). Next release will be in QT4.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* May 6, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (QA of EM Segmenter module, work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* April 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Open Discussion for Packaging WF QT Modules as Slicer4 extensions (waiting for SOPs)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review supported projects http://wiki.na-mic.org/Wiki/index.php/File:SlicerWF_EMSegmentProjectsReview.zip &lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (required by Study)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Slicer Modules General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Standardizing Crop Volumes Output (with A. Fedorov's module). Review for required updates of existing product (PET/CT, CARMA)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Open Discussion for Packaging WF QT Modules as Slicer4 extensions (waiting for SOPs)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review supported projects http://wiki.na-mic.org/Wiki/index.php/File:SlicerWF_EMSegmentProjectsReview.zip &lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (required by Study)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Slicer Modules General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Standardizing Crop Volumes Output (with A. Fedorov's module)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 22, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Beta release ready. Demo Location: http://cni29.bwh.harvard.edu/SlicerWFDemo/index.php&lt;br /&gt;
* TODO: Tutorial. Original inputs copy/renaming&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 15, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Adding App server auto-config features&lt;br /&gt;
* Finalizing the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 08, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Second release beta build tested on cosutmer side &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review registration quality (with Dr. Meier). Angiography images' Resampling tuned. &lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 01, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the second release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
XNat Integration&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* (Java) GUI for Project Browsing and DICOM Series Upload. Post-upload DICOM processing tested and debugged&amp;lt;br&amp;gt;&lt;br /&gt;
* Ready for integration with mi2b2 client.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Migrated to Latest Slicer 3.6.3 stable release: only the Input scene had to be updated, the API remained the same&lt;br /&gt;
* Tested EM Segmenter with CMTK4Slicer extension - processing takes to much time on Linux_64bit machine, rolled back to BRAINSFit registration. When used on Mac OS X build, the Slicer could not start (bug report 1126).&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SPECTRE Scull Stripping:&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Testes for various use cases: the module is extremely sensitive to T1 MRI quality (does not work for most MRIs from PET/CT project&lt;br /&gt;
* TODO next week: check for FLAIR images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Slicer4 QT GUI and Cropping activity in progress.&amp;lt;br&amp;gt;&lt;br /&gt;
* Tried direct MRA to MRA registration option: resampling with LMRI registration transforms works better.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Extra VOI labels revised&lt;br /&gt;
* Debugging of SUV results' renormalization step&lt;br /&gt;
* TODO: ICC extraction / whole brain total uptake computing; EM Segmentation for R_WM, L_WM SUV computing and BPH estimation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SCULL STRIPPING/SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Installed and tested CLI option on Linux_64bit platform&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Workflow interruption before BSPline registraton: BPEL Module completed. Slicer4 QT GUI and Cropping activity in prorgess.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Implemented and Tested with end-users proposed changes: denormalization of SUV results, adding more VOI labels, added FLAIR MRI in addition to T1s for VOI drawing&lt;br /&gt;
* Tested manual ICC extraction using PET scans: works satisfactory with island removal and cropping followed by threshold level labeling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4&lt;br /&gt;
* Change proposed: interrupt workflow after affine registration and have user crop the VOI. This is to prevent excessive deformations for BSpline registration and resampling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4. User has option to choose the atlas that fits better for the given subject (NOTE: hardcoding must be rewritten for atlas linking)&lt;br /&gt;
* PETCT test - the problem is that T1s are low resolution and with contrast. Proposed using T1s without contrast&lt;br /&gt;
* PETCT change request: users wants to compute SUV for entire ICC. Had demo how to segment brainmask/ICC using PET scan. The derived brainmask label can be used for SUV computation.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - cmpleted&lt;br /&gt;
* Sample cases run - excessive deformation after BSpline registration hase&lt;br /&gt;
* Next week plan - pull tuning controls to front-end of pipeline API, start working of QT module for CARMA registration&lt;br /&gt;
* May consider other than BRAINSFit registration modules&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Design plan for change request: more VOI labels, add FLAIR in addition to T1 for VOI drawing, T1s segmentation&lt;br /&gt;
* Tested segmentation for sample cases - artifacts from poor quality MRIs lead to exclusion of parts of ICC from segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Completed troubleshooting of EMSegmenter module calling from Java (need TCL libs to be pulled from Slicer environment)&lt;br /&gt;
* Tested EMSegmenter autoruns for HIV and Pediatric MS patiens. Work as expected, subject to improvement of PED MS case segmentation by building better skull/neck/air atalses&lt;br /&gt;
* Suggested usage of two subsets of atalases: with and without neck. The Subject MRIs have to be cropped accordingly or best fit atlas has to be selected&lt;br /&gt;
* Made no-neck cropped atlas collection for default EMSegmenter scenario&lt;br /&gt;
* Tested with PET/CT study MRI cases - see above &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - in progress&lt;br /&gt;
* Next week goal - have back end processing ready&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Longitudinal Study&lt;br /&gt;
* Added MRI registration to the pipeline&lt;br /&gt;
* Troubleshooting of complex XML schema issues on Linux machines (some modules working on MAC do not work on Linux). As a workaround - did not include MRI convert and register part into base BPEL module. Used separate services (transparent for end-user)&lt;br /&gt;
* TODO next week for change request completion: explicit pixel type casting for MRI in BRAINSFit, VOI MRML scene update (currently MRI added on top of schema)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* February 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipeline for Pediatric MRI. Same scenario as for HIV Project, icbm pediatric atlases (Completed, verified)&lt;br /&gt;
* Collected NIH healthy brain development atlases: various age ranges from 4.5 to 18 yo. Converted to Slicer readable format &lt;br /&gt;
* Work on web services for the new automated EM Segmenter module (release Nov 10 - current). Verified task completion both for adult and pediatric images. Discussed tuning parameters for work load balance on workstations.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Started working on MRI registration to the reference CT scans. &lt;br /&gt;
* Design specs for optional White Matter segmentation for SUV computing.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* February 4, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipelines for Pediatric MRI (in progress)&lt;br /&gt;
* Adapting Pediatric T1 atlases for &amp;quot;Human Brain&amp;quot; build-in EM Segmentation wizard (in progress)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 28, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Verifying EM Segmenter module for latest builds and HIV/PED MS Studies (report pending)&lt;br /&gt;
* Work with SPECTRE module developers with pediatric MRI brainmask extraction&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* January 21, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Compiling plan for WF FrontEnd GUI migration to Slicer4/QT Widgets&lt;br /&gt;
* Preparing for annual progress report&lt;br /&gt;
&lt;br /&gt;
* January 14, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI: Integrated into the Slicer4 as Slicelet (or thin Client)&lt;br /&gt;
* Participation at AHM-2011, discussing integration of SPECTRE module and updated approach to EM-Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA&lt;br /&gt;
&lt;br /&gt;
* January 7, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* HIV project workflow delivered. Major additions relate to user convenience: &lt;br /&gt;
- Project-specific parameter settings, importing T1s and brainmasks from FreeSurfer outputs with conversion to NIFTI, resampling brainmask to original scans and automatied subject addition.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Follow up with end user: need to add MRI scans, if available, addition and registration to CT in order to ease VOI drawings.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
 &lt;br /&gt;
* December 31, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Follow-up with user Experience for AGING Study Segmentation (Positive feedback)&lt;br /&gt;
* Target date for HIV project delivery - next week&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Self-training for QT widget development&amp;lt;br&amp;gt;&lt;br /&gt;
* Outlined Workflow Rich Clients migration strategy from Java to QT/Slicer4:&amp;lt;br&amp;gt;&lt;br /&gt;
** Use Java Stubs (similar to SPECTRE integration) or file binding for envocation of workflow pipelines. (See SOAP remark below)&lt;br /&gt;
** Direct Web Servisec calls must be wrapped into REST protocol. The reason: NON-commerchial QT kit does not include SOAP protocol for web servises.&lt;br /&gt;
** The GUI will be implemented as page widget or QT dialog GUI forms called from within Slicer4.&lt;br /&gt;
** Communications between Slicer4 and WF GUI will be set via child-parent and signal-slot relations&lt;br /&gt;
* Worked on a Prototype for Basic EM Segmentation QT widget (70% complete). Will work on integrtion with SLicer4 during the AHM-2010&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
XNAT Integration&lt;br /&gt;
* Debugged XNAT RESTFul API usage for uplaoding DICOM series followed by header data extraction and image snapshots creation&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Added compensation for failed atlas registration (subject for old poor quality pseudo-T1 images): blank probability maps are created in case of failure.&lt;br /&gt;
* Data preparation module for FreeSurfer data import near completion. Expected time for deployment at end-users workstations - first week of January&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Discussed strategy for EM Segmentation pipeline solutions collection (K. Pohl, R. Kikinis)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* RE-using the same core workflow as for 1-channel EM Segmentation of AGING STUDY cases&lt;br /&gt;
* Added data input preparation module: ICC label mask preparation and skull-stripping based on FreeSurfer brainmask output volume.&lt;br /&gt;
* Two-channel EM segmentation pipeline (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE / GENERAL Development &amp;lt;br&amp;gt;&lt;br /&gt;
* Worked on plans for migrating fro rich workflow Java clients to embedded workflow windows inside the Slicer.&amp;lt;br&amp;gt;&lt;br /&gt;
The embedded workflow management clients are to be implemented with QT/PyQT toolkits&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
INTEGRATION WITH XNAT:&amp;lt;br&amp;gt;&lt;br /&gt;
* Automated DICOM series upload with triggering DICOM headers parsing at XNat site (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress. &lt;br /&gt;
- Results upload to XNat (Completed) &amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat based on user's input (Project + Subject + PET or CT session / scan) (Completed)&amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat - perfomance boosting solution for downloads found , web services services are created, relinking for the client side in progress &amp;lt;br&amp;gt;&lt;br /&gt;
- Xnat querying for subjects and automated subject addition into the workflow (In Progress) &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-segmentation module added for auto correction of segmentation results. Particularly - relabeling CSF voxels segmented as Air inside the intracranial cavity. This was requested by end-users after processing images with zero-signals in CSF voxels &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting automated dual-echo DICOM images conversion and split into two NRRD volumes&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT / EM Segmentation pipeline:&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting memory allocation issues for scull-stripping module SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
COPD Project:&amp;lt;br&amp;gt;&lt;br /&gt;
* Benchmark test for accelerated DICOM downloads from XNat (remoote XNat Central server): we can handle at least 6 cases (4 CT scans in each) per hour, which is compatible with current workload quotes on SPL cluster processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* December 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Deployed Version 1. &amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Test project chosen as a closest match to registration scenario: Pediatric MS Cases from MGH - requires periodic image preview for different &lt;br /&gt;
modalities taken from vaious time points. Label maps for VOIs resampling is also required.&lt;br /&gt;
&lt;br /&gt;
* November 26, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user. Version 1 is complete&amp;lt;br&amp;gt;&lt;br /&gt;
* Started working on integration with XNat&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on input data organizing modules&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 19, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user (70% done)&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Universal Registration Workflow for Longitudinal Studies - design specs in progress&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 12, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Minor tuning to EM Segmentation template as of users' feedback&lt;br /&gt;
* Users started using the workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed input data conversion from Genesis to Slicer native or NIFTI format. Our help may be needed in input data organizing.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Tuned application according to co-laborators (PNL) needs&amp;lt;br&amp;gt;&lt;br /&gt;
* The webservices and BPEL workflow application are tested ready to accept computation requests from PNL case tracking system &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Discussed Universal Registration Workflow for Longitudinal Studies&lt;br /&gt;
* Started the thread about possible cooperation with Children hospital's image processing pipelines and integration with Xnat &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 5, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Webservices and workflow pilot project created and deployed on Psychiatry Neuroimaging Laboratory subnet &amp;lt;br&amp;gt;&lt;br /&gt;
* The V.1.0 deployment is scheduled for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 29, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Most of functionality is completed. Some volume statistics post processing is pending&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL EM SEGMENTATION Pipeline: &amp;lt;br&amp;gt;&lt;br /&gt;
* The SPECTRE scull stripping module. Started integration into EMS workflow. Made some test runs from Slicer GUI&amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Identified as a candidate for Workflow Application&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 22, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* All back-end functionality are implemented&amp;lt;br&amp;gt;&lt;br /&gt;
* EM Segmentation scene usability is confirmed by end-user&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for next week: add Label Statistics computation for CSF/Brain/ICC &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 15, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* The latest (October) builds of Slicer 3.6.2 produced acceptable results. This was verified by the target users. The EM Segmentation will be performed on Slicer 3.6.2 or later&amp;lt;br&amp;gt;&lt;br /&gt;
* The new Web services had been created and added to the pipeline as optional processing steps: Biasfield correction (implement novel N2ITKBiasFieldCorrection module) and Volume's scalar datatype casting (as workaround for Biasfield correction module not preserving image scalar datatype - the bug is filed) &amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed the Front-End GUI design with target users. The design pattern is taken from the PETCT project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 8, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-deployment support. Tuned CT registration as of user's feedback.&lt;br /&gt;
* Adapting to the Single Slicer build: Slicer 3.6.2. Found label duplicates in the label lookup table - will ask user if it's tolerable. Waiting for the Slicer 3.6.2 build that contains all required modules. Rolling back label tag appending code for SUVs - the latest Slicer build appends the tags.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Resumed development. The priorities are set for usage of Slicer 3.6.2 - subject for EM Segmentation scene tuning. Continued coding for Scene creation for Slicer 2.8 - as a backup option for ongoing research project.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 1, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized V1.0 release based on end-user feedback: updates relate mostly to error proofing and SUV values representation&lt;br /&gt;
* Post-deployment support. Users pre-processed first set of patients &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* September 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* System deployed and tested at End Users' site.&amp;lt;br&amp;gt;Users are trained to perform all tasks required by the workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
* Got positive feedback with suggestions on Slicer Scenes' layouts improvement and PET scans' SUV (standard uptake values) results display&lt;br /&gt;
* Two distribution packages are assembled: Lunix and MAC OS versions. The difference in two packages is in specific Slicer3.6/3.7 builds - subject to Slicer Linux builds debugging.&amp;lt;br&amp;gt; As a workaround for Linux deployment - multiple Slicer builds are used to perform various tasks (registration, opening editing scenes in Slicer, SUV computing)&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for coming week - finalize V1.0 release based on end-user feedback&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Embedded SUV computations into the workflow (as system calls - will be translated into web service later)&amp;lt;br&amp;gt;&lt;br /&gt;
* Pre-release demo for end users.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Create and debug EM Segmenter scenes template for Slicer 3.6 and 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* September 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation - workflow pipeline and deployment verified&amp;lt;br&amp;gt;&lt;br /&gt;
* Tested EM Segmentation scenes within Slicer 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
* Started migration of EM Segmentation to Slicer 3.6. Discovered issues had been reported to EM Segmenter module designers &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* August 29 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation completed. Preprocessing Pipleine completed 80% (subject for input registration parameters tuning) &amp;lt;br&amp;gt;&lt;br /&gt;
* Most webservices (for registration and resampling steps) had been taken and re-used from PET/CT ROI/Longitudinal Study - showing the advantage of service-oriented software design and deployment.&lt;br /&gt;
* Continued on distribution and deployment of the service/workflow applications: on PET/CT and AGING STUDY projects.&lt;br /&gt;
&lt;br /&gt;
PEDIATRIC Multiple Sclerosis Cohort. Support of multi-center distributed processing project&amp;lt;br&amp;gt;&lt;br /&gt;
* Introduced Slicer 3.6 for the MS Lesion Assessment step performed at Mayo Clinic. Images are being transferred from image repository at BWH and automatically opened and arranged within Slicer GUI for reading.  This was replacement of Client GUI using MIPAV that stopped working on new computers at Mayo Clinic.&lt;br /&gt;
The images are being loaded via generated MRML Scenes same way as in PET/CT and AGING STUDY projects &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* August 22 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Preprocessing pipeline merge with SUV computations &amp;lt;br&amp;gt;&lt;br /&gt;
- QA for SUVs computation was performed by Wendy Plesniak for images with known uptake values. &amp;lt;br&amp;gt;&lt;br /&gt;
- Discovered that image cropping step (not related to automated registration pipeline and SUVs computing) smoothes the images by doing interpolation when used with default settings. Got suggestions from Steve Piper using Nearest-Neighbor interpolation (&amp;quot;no interpolation&amp;quot;) for a time being&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
- This is the new project candidate. Requested for the images with failed manual segmentation and/or segmentation with FreeSurfer. The EM Segmentation run showed most acceptable results on one of the problem images back in February &amp;lt;br&amp;gt;&lt;br /&gt;
- The workflow will be developed and deployed similar to PET/CT ROI Longitudinal study approach - all preprocessing steps will be done with Slicer modules, all runs will be performed on local end-user machines.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
 &lt;br /&gt;
&lt;br /&gt;
* August 15 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- First 5 cases with 3-4 time points preprocessed for SUVs computation&lt;br /&gt;
&lt;br /&gt;
* August 8 2010&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Testing of installation and operation at users' site (Performed by Wendy Plesniak)&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* July 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Delivered beta version of registration pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
- Prepared installation and user manuals &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* June 11, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Registration modules completed &amp;lt;br&amp;gt;&lt;br /&gt;
- Irregular cases registration problem solved (when whole body and brain only scans are mixed for a timepoint)&amp;lt;br&amp;gt;&lt;br /&gt;
- Live demo of case setup and registration workflow for end users. Real case with 4 timepoints used&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Coming week plans&amp;lt;br&amp;gt;&lt;br /&gt;
- Adjust workflow based on end users' feedback&amp;lt;br&amp;gt;&lt;br /&gt;
- Integration with SUVs computing for PET scans&amp;lt;br&amp;gt;&lt;br /&gt;
- GUI for workflows dispatching and data organizing&amp;lt;br&amp;gt;&lt;br /&gt;
- (TBD) Integration with 4D time series analysis Slicer module&amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
* May 28, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- Migration to the latest Slicer 3.6 release candidate &amp;lt;br&amp;gt;&lt;br /&gt;
- Added webservice for new registration module: BRAINSFit &amp;lt;br&amp;gt;&lt;br /&gt;
- Test runs for new patients with 4 timepoints' scans &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Plans for next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI &amp;lt;br&amp;gt;&lt;br /&gt;
- processing workflow demo for end user &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 21, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Pilot version of portable web services and automated workflow tested: &amp;lt;br&amp;gt;&lt;br /&gt;
Linux: workflow and visual review passed&amp;lt;br&amp;gt;&lt;br /&gt;
Stress test for 25 timepoints passed &amp;lt;br&amp;gt;&lt;br /&gt;
MAC OS: workflow passed, visual review failing when PET/CT images are loaded into GUI simultaneously (bug report submitted)&amp;lt;br&amp;gt;&lt;br /&gt;
Windows: need to adapt command line modules and workflow management system to sygwin environment&amp;lt;br&amp;gt;&lt;br /&gt;
Plans for next week: integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI&lt;br /&gt;
&lt;br /&gt;
* May 7, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Selected registration and resampling modules with more precise and stable outputs. &amp;lt;br&amp;gt;&lt;br /&gt;
Started building portable web services and automated workflow &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 30, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- manual walk through the processing steps: ROI cropping, registration/resampling, PET pharmaceutical DICOM data retention. &amp;lt;br&amp;gt;&lt;br /&gt;
- testing workflow and web services packages distribution to end-users' machines&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* April 23, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : testing various registration and re-sampling algorithms (work in progress)&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation: as of collaborators' request, run existing EM Segmentation workflow for older low resolution pseudo-T1 images. The EM Segmentation works for those images with manual sampling. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 16, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
  Social Cognition Study: started Cortical Thickness Measurement module build (bases on NA-MIC ARCTIC pipeline) &amp;lt;br&amp;gt;&lt;br /&gt;
  PET/CT ROI/Longitudinal Study Registration : Design specs, PET-to-CT images registration tests on training data. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 9, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. GUI update based on end-user experience.&amp;lt;br&amp;gt;&lt;br /&gt;
User request: automated label maps' volumes calculation (Currently possible from Slicer3 GUI)&amp;lt;br&amp;gt; &lt;br /&gt;
PET/CT ROI Project. Initial design specs discussion with end-users and co-developers&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure&lt;br /&gt;
Verification of segmentation workflow GUI: from registering new case to reviewing results&amp;lt;br&amp;gt;&lt;br /&gt;
Cross study test of segmentation workflow: MGH/MS Center data - success,  HIV Project data - some EM Segmentation scene tuning is needed &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*&lt;br /&gt;
* April 2, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. Segmentation workflow completed&amp;lt;br&amp;gt;&lt;br /&gt;
* Coming Week plans:&amp;lt;br&amp;gt;&lt;br /&gt;
- Document Segmentation Workflow. Follow up with end users &amp;lt;br&amp;gt;&lt;br /&gt;
- Start with Cortical Thickness and ROI-in-longitudinal studies workflows&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* March 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All essential processing and workflow interaction clients are ready.&amp;lt;br&amp;gt;&lt;br /&gt;
- Completed segmentation for 10 out of 50 patients. The remaining cases will be finalized upon manual lesion segmentation and QC verification of WM/GM/CSF and Deep GM segmentation's. &amp;lt;br&amp;gt;&lt;br /&gt;
- TODO next week: refine QC GUI and data tracking / progress monitoring schema. &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&amp;lt;br&amp;gt;&lt;br /&gt;
- New Slicer3 web services added: re-slicing with reference image volume, casting image scalar type &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
* March 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Segmentation maps Merging Services for GM/WM/CSF (Slicer EM Segemnter), Lesion (Slicer, Manual), and Deep GM (FreeSurfer)  &amp;lt;br&amp;gt;&lt;br /&gt;
- Deep GM segmentation pipeline adopted as optional service for Social Cognition Study (22 out of 50 cases processed) &amp;lt;br&amp;gt;&lt;br /&gt;
- (In progress) GUI client for Launching Segmentation results merging with optional Deep GM segmentation with FreeSurfer &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- Complete GUI Client for Segmentation result merging &amp;lt;br&amp;gt;&lt;br /&gt;
- Progress Monitoring services for entire Study processing: EM Segmenter Preprocessing, EM Segmentation, Lesion Segmentation (including human activities assignments), Deep GM segmentation, and results consolidation. &amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* March 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All 50 cases went through &amp;quot;basic&amp;quot; One-channel EM segmentation (GM/WM/CSF) &amp;lt;br&amp;gt;&lt;br /&gt;
- Basic pipeline start-up command line client created: user has two options - request brainmask extraction or provide with previously extracted brainmask for a given subject &amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison of GM/WN/CSF performed for Slicer EM Segmenter and FreeSurfer recon-all (used with default settings). &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmenter provides more accurate output &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmentation pipeline runs faster (40 minutes vs 12 hrs when no brainmask extraction requested) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO:&amp;lt;br&amp;gt;&lt;br /&gt;
- merging modules for automatic 1-channel EM segmentation and manual lesion segmentation &amp;lt;br&amp;gt;&lt;br /&gt;
- Emerge Cortical Thickness pipeline project: use NAC ARCTIC processing steps and modules &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Selected stable EM Segmentation scenario: White Matter, Gray Matter, and Cerebrospinal Fluid &amp;lt;br&amp;gt;&lt;br /&gt;
- First 16 cases are segmented for selected scenario. Nine more cases are preprocessed for EM Segmentation.&amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison to segmentation with FreeSurfer showed better accuracy for Slicer2 EMSegmenter &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure &amp;lt;br&amp;gt;&lt;br /&gt;
- Three prerpcocessed cases failed during volume ICC masking with in-house build utility. Evaluated switching to Slicer3 Mask and island removing modules.&amp;lt;br&amp;gt;&lt;br /&gt;
- Initial design specs discussion for cortical thickness measurement pipeline. ARCTIC pipeline selected. ARCTIC preprocessing steps signifficantly overlap with EM Segmentation preprocessing workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
  &lt;br /&gt;
* February 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: &amp;lt;br&amp;gt;&lt;br /&gt;
A) parameters tuning for EM Segmenter itself (work with EM Segmenter developer), template scenes creation &amp;lt;br&amp;gt;&lt;br /&gt;
B) update preprocessing pipeline - deep gray matter atlases included &amp;lt;br&amp;gt;&lt;br /&gt;
C) test and debug preprocesing pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
D) identified missing modules: atlas autocalibration for EM Segmentation scene, Island removal for ICC mask&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- Review currently deployed modules. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: reviewed firts seven subjects' outputs, added volume orientation module into pipeline (prevents ICBM atlas linear registration failures)&amp;lt;br&amp;gt;&lt;br /&gt;
- Fused ICC(brainmask) extraction module with EM Segmenter preprocessing. Three scenarious implemented: start with pre-extracted ICC mask (longitudinal studies case), run with ICC ectration, run with ICC extraction AND ICC correction before ICBM atlas preporcessing. &amp;lt;br&amp;gt;&lt;br /&gt;
- Completion of Human activities GUI (QC, ICC Correction) planned for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: Volume Orientation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: automated preprocessing pipeline for Slicer2 EM Segmenter test version deployed. Seven cases pre-processed.&lt;br /&gt;
- PET Quantitative measurements: Preliminary design specs discussion.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: BSplineRegistration (for non-linear registration), ResampleVolume2 (for atlases resampling based on image atlase templates registration). Local and Network runs are implemented, Cluster/GridWizard implementation pending.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Slicer EM Segmenter module: preprocessing design for Slicer2 EM Segmenter&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Adapting for Slicer2 EM Segmenter (mostly from pipelines and services for previous projects)&lt;br /&gt;
  -- Integration with FreeSurfer modules for bisafield correction, brainmask extraction, and linear registration of ICBM atlases&lt;br /&gt;
  -- Preprocessing updates for non-linear registration of ICBM atlases with Slicer2 (image re-orientation service designed)&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 29, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- EM Segmentaton pipeline: preprocessing results are being transferred to XNat (anonymized data, Central XNat) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Slicer EM Segmenter module: discussed agenda and scheduled a work meeting for Social Cognition Study image segmentation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Testing stage, 95% completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- SPL XNat server: verified data exchange via RESTfull web services.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 22, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Follow up with White Matter Lesion Segmenter and Scull Stripping Modules developers: Work in Progress&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Work in Progress, 60%+ completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Discussed SPINE image repository migration to XNat&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 15, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. &lt;br /&gt;
- Social Cognition Study: &lt;br /&gt;
Work-in-progress on intermediate (reconstruction) and results (resources) data storage at XNat.&lt;br /&gt;
&amp;lt;br&amp;gt;Reviewing and preparation more cases for EM Segmentor (Slicer 3.5) tuning.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* NA-MIC Project Week&lt;br /&gt;
Selecting candidate Slicer modules for other than Lesion EM Segmentation topics of Social Cognition study: Withe Matter Lesion Segmenter (UNC), Scull Stripping utility from UIOWA.&lt;br /&gt;
Reviewing issues of currently used Scull Stripping Slicer Extension and Slicer 3.5 EM Segmenter.&lt;br /&gt;
&amp;lt;br&amp;gt;XNat Data organizing training&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 1, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Preparation of Demo for NA-MIC work week: &lt;br /&gt;
- COPD Study. Added Remote pipepline start interface (represents real world scenario where Xnat repository, Processing modules and User are at different sites)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
- EM Segmentation. Added human activities steps to the workflow: ICC (brainmask) correction and EM Segmantation scena load per se.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 25, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Pilot workflow pipeline for EM Segmentation (all steps except user-activity step: ICC correction assignment and tracking)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 18, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Build and tested web services for EM Segmentation image preprocessing: DICOM-to-NRRD conversion, registration, skull stripping, image masking.&lt;br /&gt;
Started building workflow pipeline (subject to finish first version next week)&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Started Collecting Library of Slicer Build number vs. functional modules and extensions.&lt;br /&gt;
Plan for NAMIC project week: scheduled meetings for XNat data customization, Skull-stripping modules tuning, identified Social Cognition study cases that fail EM Segmentation processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 11, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Updating and verification of EM Segmentation Scenario&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Projects:ARRA:SlicerWF:UseCaseScenarios#Usecase_MS_lesion_Assessment&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Familiarizing with Slicer3.4/5 Modules required for implementation of EM Segmentation Scenario. Participation in debugging and/or usage tuning of Dicom Conversion, Registration, Skull Stripping, Masking, and Image Casting modules. &lt;br /&gt;
&lt;br /&gt;
* December 4, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Slicer3.4's EM Segmentation and Visual QC as part of image processing pipeline for Social Cognition Study for MS Patients.&lt;br /&gt;
Project emerged. EM Segmentation template creation debugged.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
Emphysema Measurements (COPD Study) - workflow stability and scalability test.&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 27, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Emphysema Measurements (COPD Study).&lt;br /&gt;
Added compensation for long running calculations and time-outs to the main computing pipeline.&lt;br /&gt;
Visual QC (work in progress)&lt;br /&gt;
** Infrastructure&lt;br /&gt;
XNat data structure customization, metadata storage, results consolidation: new feature request list creation (work in progress)&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 13, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
*** Pilot system for whole processing cycle for Emphysema Measurements (COPD Study) including the following:&lt;br /&gt;
Web query for CT session file list download&lt;br /&gt;
Pilot user interface for submitting the file list and starting processing pipeline&lt;br /&gt;
Notification about processing steps and failures&lt;br /&gt;
Upload results to XNat repository (at this stage results are uploaded into same folder where original scans are(*))&lt;br /&gt;
*** Immediate Plans&lt;br /&gt;
Complete Visual QC module&lt;br /&gt;
Design and implement meta-data transfer to XNat (including processing details and MRML files for loading images into the 3D Slicer)&lt;br /&gt;
&lt;br /&gt;
(*)Customization of results storage&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 6, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Tuned and debugged multiple subjects processing for: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat.&lt;br /&gt;
***Started working on quality control embedding into the above scenario. Plan to complete and video-record demo next week.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***Published general Product Integration scenario flow chart to collaborators' community. Discussion is open and in progress&lt;br /&gt;
&lt;br /&gt;
* October 30, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Piloted and tested the sequence: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat(1).&lt;br /&gt;
***Performance test of overall cycle: data transfer from remote serve is a bottleneck as expected&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data browsing features reviewed.&lt;br /&gt;
(1) Not automated yet&lt;br /&gt;
* October 23, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Defined COPD processing scenario with interoperability between Xnat, 3D Slicer Command Modules, Workflow, and Gridwizard Enterprise.&lt;br /&gt;
***Pilot version of Emphysema Measurements workflow pipeline deployed.&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data transfer features reviewed. Use account at XNat Central during learning curve.&lt;br /&gt;
***Feasibility test of 3D Slicer fiducials module for ROI highlights during QC and manual image processing activities. &lt;br /&gt;
* October 16, 2009&lt;br /&gt;
**Lung CT Scans Processing. Pilot project emerged. GenerateEmphysemaMeasurements module deployed as a webservice that submits jobs to computational cluster.&lt;br /&gt;
**EM Segmentation. Familiarized with GUI steps. Started working on automation steps outlining&lt;br /&gt;
**3D Slicer and XNat interaction. Got an overview from Wendy Plesniak.&lt;br /&gt;
* October 1 - 7, 2009&lt;br /&gt;
**Selected two first priority Projects: EM Segmentation of brain MRI images; Lung CT Scans Processing (COPD Study)&lt;br /&gt;
**Got initial outline of user requirements and design specs&lt;/div&gt;</summary>
		<author><name>Azaitsev</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=70654</id>
		<title>Projects:ARRA:SlicerWF</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=70654"/>
		<updated>2011-08-29T19:01:38Z</updated>

		<summary type="html">&lt;p&gt;Azaitsev: /* Progress */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Projects:ARRASuplements|Back to Slicer ARRA home page]]&lt;br /&gt;
= Aim =&lt;br /&gt;
Supplement 3D Slicer and Extensible Neuroimaging Archive Toolkit (XNAT) with workflow management system. Provide integration and interoperability between 3D Slicer, XNAT Services and 3-rd party image processing applications and high performance computing systems. Implement it as within currently developed Structural Planning and Implementation in Neurological Exploration (SPINE) System.&lt;br /&gt;
&lt;br /&gt;
= SPINE Project Documentation =&lt;br /&gt;
[http://cni.bwh.harvard.edu/projects/spine/index.html SPINE Docs]&lt;br /&gt;
&lt;br /&gt;
= Presentations =&lt;br /&gt;
* Segmentation Workflow. PECS University Social Cognition Study.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:SlicerWF_NAC_PECS_Workflow.pdf]]&lt;br /&gt;
* EAB10_ARRA Annual Progress Report Slides.&amp;lt;br&amp;gt;&lt;br /&gt;
[[media:EAB10_ARRA_WF_2011_Zaitsev.ppt | Service Oriented Solutions for 3D Slicer. EAB10_ARRA_WF_2011. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:EAB10_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:NAMIC_ARRA_WF_2011_Zaitsev.ppt  | NAMIC Annual Report 04/2010-03/2011. NAMIC_ARRA_WF_2011_Zaitsev. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:NAMIC_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:Slicer_WF_Slicer4CARMAWorkflow.ppt  | CARMA Workflow. Cardiac Ablation Followup. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:Slicer_WF_Slicer4CARMAWorkflow.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* CARMA Project Beta release Demo Location: http://cni29.bwh.harvard.edu/SlicerWFDemo/index.php&lt;br /&gt;
&lt;br /&gt;
* Segmentation Workflows: Screenshots, scans' and study description : [[File:SlicerWF_EMSegmentProjectsReview.zip]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
= All Hands Meeting Pages =&lt;br /&gt;
* MIT 2011 Summer:&lt;br /&gt;
 Workflows Project [http://www.na-mic.org/Wiki/index.php/Summer_project_week_2011_Workflows_SOA MIT_2011_WorkFlow]&lt;br /&gt;
 Segmentation Project (MS Lesions)[http://www.na-mic.org/Wiki/index.php/2011_Summer_Project_Week_Customizing_EMSegmenter_pipelines_for_brain_lesions MIT_2011_LesionsSegmentation]&lt;br /&gt;
* Salt Lake City 2011 Winter [http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA SLC_2011_WorkFlow]&lt;br /&gt;
* MIT 2010 Summer [http://wiki.na-mic.org/Wiki/index.php/Summer_project_week_2010_Workflows_SOA MIT_2010_WorkFlow]&lt;br /&gt;
&lt;br /&gt;
= Research Plan =&lt;br /&gt;
*Create a stand-alone SPINE desktop agent with fully functional data exchange and communication mechanisms towards 3D Slicer and XNAT.&lt;br /&gt;
*Develop Service Oriented Architecture (SOA) SPINE System that will include 3D Slicer image processing modules deployed as web services as well as a workflow management system to orchestrate interaction between 3D Slicer, XNAT, and 3-rd party tools.&lt;br /&gt;
*Implement two-way control and communications between 3D Slicer and SPINE modules.&lt;br /&gt;
*Adapt SPINE System for cluster and grid computing scenarios.&lt;br /&gt;
*Provide with workflow and 3D Slicer web service wrappers editing tools.&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:UseCaseScenarios| Use Case scenarios]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PETCTWorkflow| PETCTWorkflow]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:AgingStudySegmentation| AgingStudySegmentation]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:TwoTensorTractography| TwoTensorTractography]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:LongitudinalMultimodalityRegistrationSuite| LongitudinalMultimodalityRegistrationSuite]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:MigrationJavaClients2QT| MigrationJavaClients2QT]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PediatricMSSegmentation| PediatricMSSegmentation]]&lt;br /&gt;
*[[DBP3:Utah:RegSegPipeline| MRI-based study and treatment of atrial fibrillation]]&lt;br /&gt;
&lt;br /&gt;
= Application Server / Workflow Engine Downloads =&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:WFEngineDownloads| Download Links]]&lt;br /&gt;
&lt;br /&gt;
=Key Personnel=&lt;br /&gt;
* Charles Gutmann, MD., 4%,  9-17-2009 through 9-16-2011&lt;br /&gt;
* Alexander Zaitsev, Ph.D., 75%, 9-17-2009 through 9-16-2011 &lt;br /&gt;
&lt;br /&gt;
=Annual Progress Statements =&lt;br /&gt;
'''2010-11''' &amp;lt;br&amp;gt;&lt;br /&gt;
The  April 2011 – March 2011 period was devoted on developing portable workflow solutions that can be deployed on end-users' workstations or notebooks with minimal or no system administration activities. This is in contrast to the server-side deployment. The following scenarios had been deployed and used for actual projects that require the following types of workflows: PET/CT registration and computation of biomarker driven brain physiological activities, Brain MRI Images segmentation,  MRI and MRI Angiography images pre-processing for cardiac ablation outcome estimation. Some  workflows (like EM Segmentation) had been utilizing various scenarios, some research projects  (like evaluation of chemotherapy outcome) require two types of workflows to assess physiological and structural changes. Starting from the 4th Quarter of 2011, the migration project had been emerged in order to embed Workflow GUIs into newly developed Slicer4 Suite. The existing rich client Java GUI applications are being re-written as C++/QT Sliceletts units, new modules (such as cardiac ablation project support) are had been written from scratch. The latter are being deployed from the Slicer4 GUI and act at a liaison between Slicer4 and Application Server containing  workflow and Slicer modules deployed as services. The feedback from the end users indicates that Workflow approach for the complex processing improves productivity, aids to the processing standardization and contributes to the overall experience using 3D Slicer&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
=Quarterly Progress=&lt;br /&gt;
&lt;br /&gt;
* '''2d Qtr, 2011''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study: Second release deployed. &lt;br /&gt;
*** End-users completed the first Project and currently analyzing SUV values and clinical data&lt;br /&gt;
*** New features added: Human Brain Hemispheres segmentation, Scull-stripping for total SUV counts calculation, Flexibility of custom designed label look-up table usage (users can define ROI notation according to the Project needs)&lt;br /&gt;
&lt;br /&gt;
** Left Atrium Ablation Assessment (CARMA Project)&lt;br /&gt;
*** Completed workflow pipeline for automated pre-processing and manual intervention&lt;br /&gt;
*** Developed front-end GUI for the CARMA Project support in Slicer4.&lt;br /&gt;
*** Run the workflow with the end users during NAMIC Project Week&lt;br /&gt;
*** Evaluated feasibility of left atrium wall and post-ablation scar segmentation using Robust Statistical Segmentation (RSS). Identified necessary processing controls with RSS module designers&lt;br /&gt;
&lt;br /&gt;
** Multiple Sclerosis CLIMB Study&lt;br /&gt;
*** Reprocessing for lesion segmentation&lt;br /&gt;
*** Developed Web-based (Java EE 6) application for submitting cases to the workflows for EM Segmentation of MPRAGE and registration to PD/T2/FLAIR images (60% completion)&lt;br /&gt;
&lt;br /&gt;
** EM Segmentation: &lt;br /&gt;
*** Upgraded EM Segmentation services to Slicer 3.6.4&lt;br /&gt;
*** Added brain hemispheres segmentation module to the workflows (used for PET/CT Longitudinal study)&lt;br /&gt;
*** Work with EM Segmenter module developers on building pipelines for white matter lesion segmentation (work in progress)&lt;br /&gt;
&lt;br /&gt;
** Plans for the 3rd quarter&lt;br /&gt;
*** Migrate CARMA Project workflow to end-users&lt;br /&gt;
*** Packaging of Slicer4 Workflow modules and Slicer4 custom build distribution &lt;br /&gt;
*** Completion of Web-base segmentation and registration suite&lt;br /&gt;
*** Users and Developers Documentation&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* NAMIC Annual Progress Slides (April 2010 - March 2011):&lt;br /&gt;
&lt;br /&gt;
* '''1st Qtr, 2011''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study: Second release is under testing by end-users. &lt;br /&gt;
*** Added MRI registration to aid ROI drawing on PET scans&lt;br /&gt;
*** Improved SUV results reporting and added flexibility to update ROI lookup table&lt;br /&gt;
*** Automated EM Segmentation of MRI images for computing SUVs for white matter, CSF, and whole brain (80% completion)&lt;br /&gt;
*** Integration with SPECTRE scull stripping module (70% completion) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** EM Segmentation: Automated WF Pipelines are created &amp;lt;br&amp;gt;&lt;br /&gt;
*** Flexible atlas selection (Pediatric, etc) feature added&lt;br /&gt;
*** Workflows implemented for EM Segmenter 3.6.2 and 3.6.3 (1st Qtr 2011 release)&lt;br /&gt;
&lt;br /&gt;
** Cardiac ablation results follow-up: Workflow for registration and ROI selection of cardiac MRI and MR Angiography &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Wrokflow and Web Services for prospective DTI tractography modules (currently written as Matlab modules at PNL) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Web Services for SPECTRE Scull stripping module&lt;br /&gt;
*** Accuracy and performance tuning&lt;br /&gt;
*** 50% completion&lt;br /&gt;
&lt;br /&gt;
** Migration Front End GUI to Slicer4/QT:&lt;br /&gt;
*** EM Segmentation&lt;br /&gt;
*** Cardiac Ablation Study&lt;br /&gt;
&lt;br /&gt;
** DICOM Uploader and Desktop Browser for XNat Image repository (alpha version - tested for MGH MS Center studies, proposed to use with MI2B2 Clients and Services)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''4th Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study and EM Segmentation for Aging Study are deployed at end-user sites and actively used for research. &lt;br /&gt;
** Adopted EM Segmentation preprocessing pipeline for HIV Study: high resolution SPGR images, integration with FreeSurfer brainmask extraction outputs; integration of Slicer SPECTRE module for brainmask extraction is in progress.&lt;br /&gt;
** The following post-release upgrades had been implemented based on end-user feedback: Application Server basic controls are performed from Rich Client GUI as alternative to traditional IT administration activities. The controls are implemented on point-and-click bases and include web services and workflow application deployment and upgrades, application server start and stop as well as warning end user when the server is not accepting request.&lt;br /&gt;
** Added DICOM downloads and results uploads of PET/CT pipelines from and to XNat Repository&lt;br /&gt;
** Created Services and Workflow for Matlab Prototypes modules. Case Study: tractography for DTI images&lt;br /&gt;
** Extended XNAT integration services:&lt;br /&gt;
*** Browsing capabilities of XNat data repository from the Workflow Applications&lt;br /&gt;
*** Improved DICOM upload and download performance&lt;br /&gt;
*** Added Metadata organizing services for uploaded DICOM images: header data extraction, image snapshots creation. &lt;br /&gt;
** Started project for Rich Client GUI migration from Java desktop application to build into SLicer4 QT modules. This affects mostly front-end GUI and has the following approaches: distribution with the Slicer4, end-user will select desired workflow application from Slicer4 menu while QT-written modules provide with the same functionality as Java Rich Clients. Case Study for the Migration process: registration suite for longitudinal studies that include multi-modality images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* '''3d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Concentrated on building downloadable workflow applications that could run both in desktop (new) and server environment, and that require minimum IT administrative resources. The desktop deployment is in compliance with Slicer3 general deployment concept.&lt;br /&gt;
*** The following use case scenario had been chosen: PET/CT image processing for longitudinal studies, EM Segmentation for longitudinal Aging Study.&lt;br /&gt;
** Released workflow application for PET/CT image processing for longitudinal studies. Provided end users with training and documentation.&lt;br /&gt;
*** The PET/CT processing workflow was designed to be a general application used whenever both structural patterns and metabolic activities are within the research scope. &lt;br /&gt;
*** The desktop version is tuned to use minimal computer resources, so the automates processing instances do not interfere with human activities. Automated activities may include, for example, registration and PET scan's standard uptake values computing, and manual human activities may include image cropping, quality control, and labeling voxels of interest.&lt;br /&gt;
** Core services and EM Segmentation preprocessing workflow was build for retrospective Aging Study. Tuned the Slicer3 webservices for processing low grade images acquired in mid 90s. Entire workflow is implemented with Slicer3 only modules and can be deployed locally and on the servers. Usage of Service Oriented Architecture (SOA) as a core technological approach allowed reusing most of the web services that had been build for PET/CT project. &lt;br /&gt;
** Continued embedding Slicer3 application and modules into previously released processing pipelines: replaced MIPAV with Slicer3 GUI for lesion assessment step in the multi-center Pediatric MS Cohort image processing &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''2d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Completed Social Cognition Workflow Implementation. This includes EM Segmetnation pre- and post-processing pipelines, data tracking, and integration with 3d party image processing utilities, as well as processing results acquired manually with Slicer GUI.  &lt;br /&gt;
** Multi-modality image registration and ROI selection/alignment workflow for longitudinal studies. &lt;br /&gt;
*** Use case: PET/CT image processing for longitudinal studies. &lt;br /&gt;
*** Build portable library of Slicer modules as web services and workflow that are deployed and run on a end-users' worksatations without utilization of SPL and other servers. The web services include novel Slicer3 modules, such as BRAINSFit and BRAINSResamle &lt;br /&gt;
*** Started working with Slicer3 developers on Slicer 3.8 GUI wizard to communicate with workflow instances.&lt;br /&gt;
** Participated at NA-MIC Summer 2010 Project Week: [[Summer_project_week_2010_Workflows_SOA]]&lt;br /&gt;
&lt;br /&gt;
=Progress=&lt;br /&gt;
* August 19, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project:&lt;br /&gt;
* Packaging on Max OS X 64-bit: troubleshooting QT 4.6 (build tree) QT 4.7 (make package) conflicts&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
3D Slicer WF. General&lt;br /&gt;
* 3D Slicer and WF Modules presentation at MGH Radiation Oncology&lt;br /&gt;
&amp;lt;br&amp;gt;  &lt;br /&gt;
&lt;br /&gt;
* August 19, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation&lt;br /&gt;
* Deployed first release (Human Brain EM Segmentation) web request application&lt;br /&gt;
* End-users requested EM Segmentation of MS lesion on PD images (feasibility is being evaluated with EM Segmenter Team)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
3D Slicer WF. General&lt;br /&gt;
* Preparation of 3D Slicer and WF Modules presentation for MGH&lt;br /&gt;
&amp;lt;br&amp;gt;  &lt;br /&gt;
&lt;br /&gt;
* August 12, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
* Migrating build to updated Slicer4 environment  (PythonQT and new added module dependencies issues)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation&lt;br /&gt;
* Tested and reviewed EM Segmentation web app on end-users' data&lt;br /&gt;
* Updated workflow, so EM Segmentation is performed on T1 after registration to T2 or FLAIR. This gives more accurate results comparing to segmentation of high resolution image followed by resampling (have to use nearest neighbor interpolation to retain actual label values) of label map &lt;br /&gt;
&lt;br /&gt;
* August 5, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT&lt;br /&gt;
* Follow-up with end users with new Study setup&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
CARMA Project&lt;br /&gt;
* Documentation (Work in progress)&lt;br /&gt;
* Plans for next week: custom packaging (Mac Snow Leopard 64 bit), building extension, documentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation&lt;br /&gt;
* Stress-test of online segmentation requests suite for  [http://www.slicer.org/slicerWiki/index.php/EMSegmenter-Tasks#Additional_Use_Cases CLIMB Study](for BWH MS Center)&lt;br /&gt;
* Reason for building online suite: the Group is Using mostly MAC OS Tiger machines for legacy reasnos, the most recent Slicer3 builds as well as QT don't work on those machines (QT4.x runtime could not be installed).&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* July 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA Project&lt;br /&gt;
* Documentation (Work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation&lt;br /&gt;
* Work on alpha-release of online submission of segmentation requests (for BWH MS Center)&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* July 22, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
Vacation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* July 8, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
3D Slicer in General and CARMA Project&lt;br /&gt;
* Presentation and life demo at Cardiology Research Center (Moscow, Russia) [[File:RussianCardiologyCenterCARMA2011.ppt]]&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* July 1, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA V1.0&lt;br /&gt;
* Migration to new QT building environment (Mac 10 Snow Leopard). &lt;br /&gt;
* Building custom package. Issues: new features (not only WF related) are not shown on the menu of the resulting application&lt;br /&gt;
* Comparing preprocessing workflow results with published in literature data (our module produces better alignment)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*June 24, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
Project Week:&lt;br /&gt;
* Testing RSS module for left atrial wall scar segmentation&lt;br /&gt;
* Testing EM Segmenter for lesion detection on PD (requested by end-users) and FLAIR images&lt;br /&gt;
&lt;br /&gt;
EM Segmentation &lt;br /&gt;
* Web-based segmentation and registration module for MS Center. Goal: facilitate 3D SLicer modules for the cases that could not be processed with in-house build DTS+ algorithm&lt;br /&gt;
* Pipeline: Segment MPGR or T1 (user's choice), Register MPGR to PD/T2, Resample Segmentation Map to PD/T2. Completion: 60-70%.&lt;br /&gt;
* The rest will be done manually or via lesion segmentation with EM Segmenter.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* June 17, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
Preparation for Project Week&lt;br /&gt;
&lt;br /&gt;
* June 10, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
CARMA V.1.0&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code completed and tested&lt;br /&gt;
* Packaging as extension is pending (Subject for Summer 2011 Project week)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Debugging consolidation results issue(SUVs for manual and automated segmentation) &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* June 3, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Deployed on end-user's machine&lt;br /&gt;
* TODO next week: fix SUV results consolidation issue (when MRI segmented ROI got SUV computed for some subjects, only those subjects' SUVs are being added into consolidated report. &amp;quot;Raw&amp;quot; SUV values per subject are generated as expected)  &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 27, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Ready for deployment. New Features: hemispheres EM Segmentation, automated ICC/brainmask extraction using EM Segmenter, fixed controls for MRI conversion and registration&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 20, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General / PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Hemispheres EM Segmentation - adjusted for required label lookup table&lt;br /&gt;
* Use cases added for EM Segmenter General Project: http://www.slicer.org/slicerWiki/index.php/EMSegmenter-Tasks#EMSegmenter_use_cases&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SPECTRE Scull Stripping&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* The new version to be tested on coming week (After PETCT MRI processing migrated to Hemispheres scenario )&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* May 13, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General / PETCT V1.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Hemispheres EM Segmentation - technically works with labal values hardcoded in Slicer EM Segmenter - need to add manual label value edition step&lt;br /&gt;
* PETCT WF Cut for Java GUI (Pending Hemispheres label update completion). Next release will be in QT4.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* May 6, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (QA of EM Segmenter module, work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* April 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Open Discussion for Packaging WF QT Modules as Slicer4 extensions (waiting for SOPs)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review supported projects http://wiki.na-mic.org/Wiki/index.php/File:SlicerWF_EMSegmentProjectsReview.zip &lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (required by Study)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Slicer Modules General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Standardizing Crop Volumes Output (with A. Fedorov's module). Review for required updates of existing product (PET/CT, CARMA)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Open Discussion for Packaging WF QT Modules as Slicer4 extensions (waiting for SOPs)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review supported projects http://wiki.na-mic.org/Wiki/index.php/File:SlicerWF_EMSegmentProjectsReview.zip &lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (required by Study)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Slicer Modules General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Standardizing Crop Volumes Output (with A. Fedorov's module)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 22, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Beta release ready. Demo Location: http://cni29.bwh.harvard.edu/SlicerWFDemo/index.php&lt;br /&gt;
* TODO: Tutorial. Original inputs copy/renaming&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 15, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Adding App server auto-config features&lt;br /&gt;
* Finalizing the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 08, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Second release beta build tested on cosutmer side &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review registration quality (with Dr. Meier). Angiography images' Resampling tuned. &lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 01, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the second release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
XNat Integration&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* (Java) GUI for Project Browsing and DICOM Series Upload. Post-upload DICOM processing tested and debugged&amp;lt;br&amp;gt;&lt;br /&gt;
* Ready for integration with mi2b2 client.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Migrated to Latest Slicer 3.6.3 stable release: only the Input scene had to be updated, the API remained the same&lt;br /&gt;
* Tested EM Segmenter with CMTK4Slicer extension - processing takes to much time on Linux_64bit machine, rolled back to BRAINSFit registration. When used on Mac OS X build, the Slicer could not start (bug report 1126).&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SPECTRE Scull Stripping:&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Testes for various use cases: the module is extremely sensitive to T1 MRI quality (does not work for most MRIs from PET/CT project&lt;br /&gt;
* TODO next week: check for FLAIR images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Slicer4 QT GUI and Cropping activity in progress.&amp;lt;br&amp;gt;&lt;br /&gt;
* Tried direct MRA to MRA registration option: resampling with LMRI registration transforms works better.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Extra VOI labels revised&lt;br /&gt;
* Debugging of SUV results' renormalization step&lt;br /&gt;
* TODO: ICC extraction / whole brain total uptake computing; EM Segmentation for R_WM, L_WM SUV computing and BPH estimation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SCULL STRIPPING/SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Installed and tested CLI option on Linux_64bit platform&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Workflow interruption before BSPline registraton: BPEL Module completed. Slicer4 QT GUI and Cropping activity in prorgess.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Implemented and Tested with end-users proposed changes: denormalization of SUV results, adding more VOI labels, added FLAIR MRI in addition to T1s for VOI drawing&lt;br /&gt;
* Tested manual ICC extraction using PET scans: works satisfactory with island removal and cropping followed by threshold level labeling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4&lt;br /&gt;
* Change proposed: interrupt workflow after affine registration and have user crop the VOI. This is to prevent excessive deformations for BSpline registration and resampling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4. User has option to choose the atlas that fits better for the given subject (NOTE: hardcoding must be rewritten for atlas linking)&lt;br /&gt;
* PETCT test - the problem is that T1s are low resolution and with contrast. Proposed using T1s without contrast&lt;br /&gt;
* PETCT change request: users wants to compute SUV for entire ICC. Had demo how to segment brainmask/ICC using PET scan. The derived brainmask label can be used for SUV computation.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - cmpleted&lt;br /&gt;
* Sample cases run - excessive deformation after BSpline registration hase&lt;br /&gt;
* Next week plan - pull tuning controls to front-end of pipeline API, start working of QT module for CARMA registration&lt;br /&gt;
* May consider other than BRAINSFit registration modules&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Design plan for change request: more VOI labels, add FLAIR in addition to T1 for VOI drawing, T1s segmentation&lt;br /&gt;
* Tested segmentation for sample cases - artifacts from poor quality MRIs lead to exclusion of parts of ICC from segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Completed troubleshooting of EMSegmenter module calling from Java (need TCL libs to be pulled from Slicer environment)&lt;br /&gt;
* Tested EMSegmenter autoruns for HIV and Pediatric MS patiens. Work as expected, subject to improvement of PED MS case segmentation by building better skull/neck/air atalses&lt;br /&gt;
* Suggested usage of two subsets of atalases: with and without neck. The Subject MRIs have to be cropped accordingly or best fit atlas has to be selected&lt;br /&gt;
* Made no-neck cropped atlas collection for default EMSegmenter scenario&lt;br /&gt;
* Tested with PET/CT study MRI cases - see above &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - in progress&lt;br /&gt;
* Next week goal - have back end processing ready&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Longitudinal Study&lt;br /&gt;
* Added MRI registration to the pipeline&lt;br /&gt;
* Troubleshooting of complex XML schema issues on Linux machines (some modules working on MAC do not work on Linux). As a workaround - did not include MRI convert and register part into base BPEL module. Used separate services (transparent for end-user)&lt;br /&gt;
* TODO next week for change request completion: explicit pixel type casting for MRI in BRAINSFit, VOI MRML scene update (currently MRI added on top of schema)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* February 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipeline for Pediatric MRI. Same scenario as for HIV Project, icbm pediatric atlases (Completed, verified)&lt;br /&gt;
* Collected NIH healthy brain development atlases: various age ranges from 4.5 to 18 yo. Converted to Slicer readable format &lt;br /&gt;
* Work on web services for the new automated EM Segmenter module (release Nov 10 - current). Verified task completion both for adult and pediatric images. Discussed tuning parameters for work load balance on workstations.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Started working on MRI registration to the reference CT scans. &lt;br /&gt;
* Design specs for optional White Matter segmentation for SUV computing.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* February 4, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipelines for Pediatric MRI (in progress)&lt;br /&gt;
* Adapting Pediatric T1 atlases for &amp;quot;Human Brain&amp;quot; build-in EM Segmentation wizard (in progress)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 28, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Verifying EM Segmenter module for latest builds and HIV/PED MS Studies (report pending)&lt;br /&gt;
* Work with SPECTRE module developers with pediatric MRI brainmask extraction&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* January 21, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Compiling plan for WF FrontEnd GUI migration to Slicer4/QT Widgets&lt;br /&gt;
* Preparing for annual progress report&lt;br /&gt;
&lt;br /&gt;
* January 14, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI: Integrated into the Slicer4 as Slicelet (or thin Client)&lt;br /&gt;
* Participation at AHM-2011, discussing integration of SPECTRE module and updated approach to EM-Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA&lt;br /&gt;
&lt;br /&gt;
* January 7, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* HIV project workflow delivered. Major additions relate to user convenience: &lt;br /&gt;
- Project-specific parameter settings, importing T1s and brainmasks from FreeSurfer outputs with conversion to NIFTI, resampling brainmask to original scans and automatied subject addition.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Follow up with end user: need to add MRI scans, if available, addition and registration to CT in order to ease VOI drawings.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
 &lt;br /&gt;
* December 31, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Follow-up with user Experience for AGING Study Segmentation (Positive feedback)&lt;br /&gt;
* Target date for HIV project delivery - next week&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Self-training for QT widget development&amp;lt;br&amp;gt;&lt;br /&gt;
* Outlined Workflow Rich Clients migration strategy from Java to QT/Slicer4:&amp;lt;br&amp;gt;&lt;br /&gt;
** Use Java Stubs (similar to SPECTRE integration) or file binding for envocation of workflow pipelines. (See SOAP remark below)&lt;br /&gt;
** Direct Web Servisec calls must be wrapped into REST protocol. The reason: NON-commerchial QT kit does not include SOAP protocol for web servises.&lt;br /&gt;
** The GUI will be implemented as page widget or QT dialog GUI forms called from within Slicer4.&lt;br /&gt;
** Communications between Slicer4 and WF GUI will be set via child-parent and signal-slot relations&lt;br /&gt;
* Worked on a Prototype for Basic EM Segmentation QT widget (70% complete). Will work on integrtion with SLicer4 during the AHM-2010&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
XNAT Integration&lt;br /&gt;
* Debugged XNAT RESTFul API usage for uplaoding DICOM series followed by header data extraction and image snapshots creation&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Added compensation for failed atlas registration (subject for old poor quality pseudo-T1 images): blank probability maps are created in case of failure.&lt;br /&gt;
* Data preparation module for FreeSurfer data import near completion. Expected time for deployment at end-users workstations - first week of January&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Discussed strategy for EM Segmentation pipeline solutions collection (K. Pohl, R. Kikinis)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* RE-using the same core workflow as for 1-channel EM Segmentation of AGING STUDY cases&lt;br /&gt;
* Added data input preparation module: ICC label mask preparation and skull-stripping based on FreeSurfer brainmask output volume.&lt;br /&gt;
* Two-channel EM segmentation pipeline (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE / GENERAL Development &amp;lt;br&amp;gt;&lt;br /&gt;
* Worked on plans for migrating fro rich workflow Java clients to embedded workflow windows inside the Slicer.&amp;lt;br&amp;gt;&lt;br /&gt;
The embedded workflow management clients are to be implemented with QT/PyQT toolkits&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
INTEGRATION WITH XNAT:&amp;lt;br&amp;gt;&lt;br /&gt;
* Automated DICOM series upload with triggering DICOM headers parsing at XNat site (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress. &lt;br /&gt;
- Results upload to XNat (Completed) &amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat based on user's input (Project + Subject + PET or CT session / scan) (Completed)&amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat - perfomance boosting solution for downloads found , web services services are created, relinking for the client side in progress &amp;lt;br&amp;gt;&lt;br /&gt;
- Xnat querying for subjects and automated subject addition into the workflow (In Progress) &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-segmentation module added for auto correction of segmentation results. Particularly - relabeling CSF voxels segmented as Air inside the intracranial cavity. This was requested by end-users after processing images with zero-signals in CSF voxels &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting automated dual-echo DICOM images conversion and split into two NRRD volumes&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT / EM Segmentation pipeline:&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting memory allocation issues for scull-stripping module SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
COPD Project:&amp;lt;br&amp;gt;&lt;br /&gt;
* Benchmark test for accelerated DICOM downloads from XNat (remoote XNat Central server): we can handle at least 6 cases (4 CT scans in each) per hour, which is compatible with current workload quotes on SPL cluster processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* December 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Deployed Version 1. &amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Test project chosen as a closest match to registration scenario: Pediatric MS Cases from MGH - requires periodic image preview for different &lt;br /&gt;
modalities taken from vaious time points. Label maps for VOIs resampling is also required.&lt;br /&gt;
&lt;br /&gt;
* November 26, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user. Version 1 is complete&amp;lt;br&amp;gt;&lt;br /&gt;
* Started working on integration with XNat&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on input data organizing modules&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 19, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user (70% done)&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Universal Registration Workflow for Longitudinal Studies - design specs in progress&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 12, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Minor tuning to EM Segmentation template as of users' feedback&lt;br /&gt;
* Users started using the workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed input data conversion from Genesis to Slicer native or NIFTI format. Our help may be needed in input data organizing.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Tuned application according to co-laborators (PNL) needs&amp;lt;br&amp;gt;&lt;br /&gt;
* The webservices and BPEL workflow application are tested ready to accept computation requests from PNL case tracking system &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Discussed Universal Registration Workflow for Longitudinal Studies&lt;br /&gt;
* Started the thread about possible cooperation with Children hospital's image processing pipelines and integration with Xnat &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 5, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Webservices and workflow pilot project created and deployed on Psychiatry Neuroimaging Laboratory subnet &amp;lt;br&amp;gt;&lt;br /&gt;
* The V.1.0 deployment is scheduled for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 29, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Most of functionality is completed. Some volume statistics post processing is pending&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL EM SEGMENTATION Pipeline: &amp;lt;br&amp;gt;&lt;br /&gt;
* The SPECTRE scull stripping module. Started integration into EMS workflow. Made some test runs from Slicer GUI&amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Identified as a candidate for Workflow Application&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 22, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* All back-end functionality are implemented&amp;lt;br&amp;gt;&lt;br /&gt;
* EM Segmentation scene usability is confirmed by end-user&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for next week: add Label Statistics computation for CSF/Brain/ICC &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 15, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* The latest (October) builds of Slicer 3.6.2 produced acceptable results. This was verified by the target users. The EM Segmentation will be performed on Slicer 3.6.2 or later&amp;lt;br&amp;gt;&lt;br /&gt;
* The new Web services had been created and added to the pipeline as optional processing steps: Biasfield correction (implement novel N2ITKBiasFieldCorrection module) and Volume's scalar datatype casting (as workaround for Biasfield correction module not preserving image scalar datatype - the bug is filed) &amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed the Front-End GUI design with target users. The design pattern is taken from the PETCT project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 8, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-deployment support. Tuned CT registration as of user's feedback.&lt;br /&gt;
* Adapting to the Single Slicer build: Slicer 3.6.2. Found label duplicates in the label lookup table - will ask user if it's tolerable. Waiting for the Slicer 3.6.2 build that contains all required modules. Rolling back label tag appending code for SUVs - the latest Slicer build appends the tags.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Resumed development. The priorities are set for usage of Slicer 3.6.2 - subject for EM Segmentation scene tuning. Continued coding for Scene creation for Slicer 2.8 - as a backup option for ongoing research project.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 1, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized V1.0 release based on end-user feedback: updates relate mostly to error proofing and SUV values representation&lt;br /&gt;
* Post-deployment support. Users pre-processed first set of patients &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* September 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* System deployed and tested at End Users' site.&amp;lt;br&amp;gt;Users are trained to perform all tasks required by the workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
* Got positive feedback with suggestions on Slicer Scenes' layouts improvement and PET scans' SUV (standard uptake values) results display&lt;br /&gt;
* Two distribution packages are assembled: Lunix and MAC OS versions. The difference in two packages is in specific Slicer3.6/3.7 builds - subject to Slicer Linux builds debugging.&amp;lt;br&amp;gt; As a workaround for Linux deployment - multiple Slicer builds are used to perform various tasks (registration, opening editing scenes in Slicer, SUV computing)&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for coming week - finalize V1.0 release based on end-user feedback&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Embedded SUV computations into the workflow (as system calls - will be translated into web service later)&amp;lt;br&amp;gt;&lt;br /&gt;
* Pre-release demo for end users.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Create and debug EM Segmenter scenes template for Slicer 3.6 and 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* September 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation - workflow pipeline and deployment verified&amp;lt;br&amp;gt;&lt;br /&gt;
* Tested EM Segmentation scenes within Slicer 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
* Started migration of EM Segmentation to Slicer 3.6. Discovered issues had been reported to EM Segmenter module designers &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* August 29 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation completed. Preprocessing Pipleine completed 80% (subject for input registration parameters tuning) &amp;lt;br&amp;gt;&lt;br /&gt;
* Most webservices (for registration and resampling steps) had been taken and re-used from PET/CT ROI/Longitudinal Study - showing the advantage of service-oriented software design and deployment.&lt;br /&gt;
* Continued on distribution and deployment of the service/workflow applications: on PET/CT and AGING STUDY projects.&lt;br /&gt;
&lt;br /&gt;
PEDIATRIC Multiple Sclerosis Cohort. Support of multi-center distributed processing project&amp;lt;br&amp;gt;&lt;br /&gt;
* Introduced Slicer 3.6 for the MS Lesion Assessment step performed at Mayo Clinic. Images are being transferred from image repository at BWH and automatically opened and arranged within Slicer GUI for reading.  This was replacement of Client GUI using MIPAV that stopped working on new computers at Mayo Clinic.&lt;br /&gt;
The images are being loaded via generated MRML Scenes same way as in PET/CT and AGING STUDY projects &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* August 22 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Preprocessing pipeline merge with SUV computations &amp;lt;br&amp;gt;&lt;br /&gt;
- QA for SUVs computation was performed by Wendy Plesniak for images with known uptake values. &amp;lt;br&amp;gt;&lt;br /&gt;
- Discovered that image cropping step (not related to automated registration pipeline and SUVs computing) smoothes the images by doing interpolation when used with default settings. Got suggestions from Steve Piper using Nearest-Neighbor interpolation (&amp;quot;no interpolation&amp;quot;) for a time being&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
- This is the new project candidate. Requested for the images with failed manual segmentation and/or segmentation with FreeSurfer. The EM Segmentation run showed most acceptable results on one of the problem images back in February &amp;lt;br&amp;gt;&lt;br /&gt;
- The workflow will be developed and deployed similar to PET/CT ROI Longitudinal study approach - all preprocessing steps will be done with Slicer modules, all runs will be performed on local end-user machines.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
 &lt;br /&gt;
&lt;br /&gt;
* August 15 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- First 5 cases with 3-4 time points preprocessed for SUVs computation&lt;br /&gt;
&lt;br /&gt;
* August 8 2010&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Testing of installation and operation at users' site (Performed by Wendy Plesniak)&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* July 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Delivered beta version of registration pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
- Prepared installation and user manuals &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* June 11, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Registration modules completed &amp;lt;br&amp;gt;&lt;br /&gt;
- Irregular cases registration problem solved (when whole body and brain only scans are mixed for a timepoint)&amp;lt;br&amp;gt;&lt;br /&gt;
- Live demo of case setup and registration workflow for end users. Real case with 4 timepoints used&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Coming week plans&amp;lt;br&amp;gt;&lt;br /&gt;
- Adjust workflow based on end users' feedback&amp;lt;br&amp;gt;&lt;br /&gt;
- Integration with SUVs computing for PET scans&amp;lt;br&amp;gt;&lt;br /&gt;
- GUI for workflows dispatching and data organizing&amp;lt;br&amp;gt;&lt;br /&gt;
- (TBD) Integration with 4D time series analysis Slicer module&amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
* May 28, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- Migration to the latest Slicer 3.6 release candidate &amp;lt;br&amp;gt;&lt;br /&gt;
- Added webservice for new registration module: BRAINSFit &amp;lt;br&amp;gt;&lt;br /&gt;
- Test runs for new patients with 4 timepoints' scans &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Plans for next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI &amp;lt;br&amp;gt;&lt;br /&gt;
- processing workflow demo for end user &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 21, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Pilot version of portable web services and automated workflow tested: &amp;lt;br&amp;gt;&lt;br /&gt;
Linux: workflow and visual review passed&amp;lt;br&amp;gt;&lt;br /&gt;
Stress test for 25 timepoints passed &amp;lt;br&amp;gt;&lt;br /&gt;
MAC OS: workflow passed, visual review failing when PET/CT images are loaded into GUI simultaneously (bug report submitted)&amp;lt;br&amp;gt;&lt;br /&gt;
Windows: need to adapt command line modules and workflow management system to sygwin environment&amp;lt;br&amp;gt;&lt;br /&gt;
Plans for next week: integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI&lt;br /&gt;
&lt;br /&gt;
* May 7, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Selected registration and resampling modules with more precise and stable outputs. &amp;lt;br&amp;gt;&lt;br /&gt;
Started building portable web services and automated workflow &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 30, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- manual walk through the processing steps: ROI cropping, registration/resampling, PET pharmaceutical DICOM data retention. &amp;lt;br&amp;gt;&lt;br /&gt;
- testing workflow and web services packages distribution to end-users' machines&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* April 23, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : testing various registration and re-sampling algorithms (work in progress)&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation: as of collaborators' request, run existing EM Segmentation workflow for older low resolution pseudo-T1 images. The EM Segmentation works for those images with manual sampling. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 16, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
  Social Cognition Study: started Cortical Thickness Measurement module build (bases on NA-MIC ARCTIC pipeline) &amp;lt;br&amp;gt;&lt;br /&gt;
  PET/CT ROI/Longitudinal Study Registration : Design specs, PET-to-CT images registration tests on training data. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 9, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. GUI update based on end-user experience.&amp;lt;br&amp;gt;&lt;br /&gt;
User request: automated label maps' volumes calculation (Currently possible from Slicer3 GUI)&amp;lt;br&amp;gt; &lt;br /&gt;
PET/CT ROI Project. Initial design specs discussion with end-users and co-developers&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure&lt;br /&gt;
Verification of segmentation workflow GUI: from registering new case to reviewing results&amp;lt;br&amp;gt;&lt;br /&gt;
Cross study test of segmentation workflow: MGH/MS Center data - success,  HIV Project data - some EM Segmentation scene tuning is needed &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*&lt;br /&gt;
* April 2, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. Segmentation workflow completed&amp;lt;br&amp;gt;&lt;br /&gt;
* Coming Week plans:&amp;lt;br&amp;gt;&lt;br /&gt;
- Document Segmentation Workflow. Follow up with end users &amp;lt;br&amp;gt;&lt;br /&gt;
- Start with Cortical Thickness and ROI-in-longitudinal studies workflows&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* March 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All essential processing and workflow interaction clients are ready.&amp;lt;br&amp;gt;&lt;br /&gt;
- Completed segmentation for 10 out of 50 patients. The remaining cases will be finalized upon manual lesion segmentation and QC verification of WM/GM/CSF and Deep GM segmentation's. &amp;lt;br&amp;gt;&lt;br /&gt;
- TODO next week: refine QC GUI and data tracking / progress monitoring schema. &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&amp;lt;br&amp;gt;&lt;br /&gt;
- New Slicer3 web services added: re-slicing with reference image volume, casting image scalar type &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
* March 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Segmentation maps Merging Services for GM/WM/CSF (Slicer EM Segemnter), Lesion (Slicer, Manual), and Deep GM (FreeSurfer)  &amp;lt;br&amp;gt;&lt;br /&gt;
- Deep GM segmentation pipeline adopted as optional service for Social Cognition Study (22 out of 50 cases processed) &amp;lt;br&amp;gt;&lt;br /&gt;
- (In progress) GUI client for Launching Segmentation results merging with optional Deep GM segmentation with FreeSurfer &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- Complete GUI Client for Segmentation result merging &amp;lt;br&amp;gt;&lt;br /&gt;
- Progress Monitoring services for entire Study processing: EM Segmenter Preprocessing, EM Segmentation, Lesion Segmentation (including human activities assignments), Deep GM segmentation, and results consolidation. &amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* March 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All 50 cases went through &amp;quot;basic&amp;quot; One-channel EM segmentation (GM/WM/CSF) &amp;lt;br&amp;gt;&lt;br /&gt;
- Basic pipeline start-up command line client created: user has two options - request brainmask extraction or provide with previously extracted brainmask for a given subject &amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison of GM/WN/CSF performed for Slicer EM Segmenter and FreeSurfer recon-all (used with default settings). &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmenter provides more accurate output &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmentation pipeline runs faster (40 minutes vs 12 hrs when no brainmask extraction requested) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO:&amp;lt;br&amp;gt;&lt;br /&gt;
- merging modules for automatic 1-channel EM segmentation and manual lesion segmentation &amp;lt;br&amp;gt;&lt;br /&gt;
- Emerge Cortical Thickness pipeline project: use NAC ARCTIC processing steps and modules &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Selected stable EM Segmentation scenario: White Matter, Gray Matter, and Cerebrospinal Fluid &amp;lt;br&amp;gt;&lt;br /&gt;
- First 16 cases are segmented for selected scenario. Nine more cases are preprocessed for EM Segmentation.&amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison to segmentation with FreeSurfer showed better accuracy for Slicer2 EMSegmenter &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure &amp;lt;br&amp;gt;&lt;br /&gt;
- Three prerpcocessed cases failed during volume ICC masking with in-house build utility. Evaluated switching to Slicer3 Mask and island removing modules.&amp;lt;br&amp;gt;&lt;br /&gt;
- Initial design specs discussion for cortical thickness measurement pipeline. ARCTIC pipeline selected. ARCTIC preprocessing steps signifficantly overlap with EM Segmentation preprocessing workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
  &lt;br /&gt;
* February 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: &amp;lt;br&amp;gt;&lt;br /&gt;
A) parameters tuning for EM Segmenter itself (work with EM Segmenter developer), template scenes creation &amp;lt;br&amp;gt;&lt;br /&gt;
B) update preprocessing pipeline - deep gray matter atlases included &amp;lt;br&amp;gt;&lt;br /&gt;
C) test and debug preprocesing pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
D) identified missing modules: atlas autocalibration for EM Segmentation scene, Island removal for ICC mask&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- Review currently deployed modules. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: reviewed firts seven subjects' outputs, added volume orientation module into pipeline (prevents ICBM atlas linear registration failures)&amp;lt;br&amp;gt;&lt;br /&gt;
- Fused ICC(brainmask) extraction module with EM Segmenter preprocessing. Three scenarious implemented: start with pre-extracted ICC mask (longitudinal studies case), run with ICC ectration, run with ICC extraction AND ICC correction before ICBM atlas preporcessing. &amp;lt;br&amp;gt;&lt;br /&gt;
- Completion of Human activities GUI (QC, ICC Correction) planned for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: Volume Orientation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: automated preprocessing pipeline for Slicer2 EM Segmenter test version deployed. Seven cases pre-processed.&lt;br /&gt;
- PET Quantitative measurements: Preliminary design specs discussion.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: BSplineRegistration (for non-linear registration), ResampleVolume2 (for atlases resampling based on image atlase templates registration). Local and Network runs are implemented, Cluster/GridWizard implementation pending.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Slicer EM Segmenter module: preprocessing design for Slicer2 EM Segmenter&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Adapting for Slicer2 EM Segmenter (mostly from pipelines and services for previous projects)&lt;br /&gt;
  -- Integration with FreeSurfer modules for bisafield correction, brainmask extraction, and linear registration of ICBM atlases&lt;br /&gt;
  -- Preprocessing updates for non-linear registration of ICBM atlases with Slicer2 (image re-orientation service designed)&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 29, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- EM Segmentaton pipeline: preprocessing results are being transferred to XNat (anonymized data, Central XNat) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Slicer EM Segmenter module: discussed agenda and scheduled a work meeting for Social Cognition Study image segmentation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Testing stage, 95% completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- SPL XNat server: verified data exchange via RESTfull web services.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 22, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Follow up with White Matter Lesion Segmenter and Scull Stripping Modules developers: Work in Progress&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Work in Progress, 60%+ completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Discussed SPINE image repository migration to XNat&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 15, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. &lt;br /&gt;
- Social Cognition Study: &lt;br /&gt;
Work-in-progress on intermediate (reconstruction) and results (resources) data storage at XNat.&lt;br /&gt;
&amp;lt;br&amp;gt;Reviewing and preparation more cases for EM Segmentor (Slicer 3.5) tuning.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* NA-MIC Project Week&lt;br /&gt;
Selecting candidate Slicer modules for other than Lesion EM Segmentation topics of Social Cognition study: Withe Matter Lesion Segmenter (UNC), Scull Stripping utility from UIOWA.&lt;br /&gt;
Reviewing issues of currently used Scull Stripping Slicer Extension and Slicer 3.5 EM Segmenter.&lt;br /&gt;
&amp;lt;br&amp;gt;XNat Data organizing training&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 1, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Preparation of Demo for NA-MIC work week: &lt;br /&gt;
- COPD Study. Added Remote pipepline start interface (represents real world scenario where Xnat repository, Processing modules and User are at different sites)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
- EM Segmentation. Added human activities steps to the workflow: ICC (brainmask) correction and EM Segmantation scena load per se.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 25, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Pilot workflow pipeline for EM Segmentation (all steps except user-activity step: ICC correction assignment and tracking)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 18, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Build and tested web services for EM Segmentation image preprocessing: DICOM-to-NRRD conversion, registration, skull stripping, image masking.&lt;br /&gt;
Started building workflow pipeline (subject to finish first version next week)&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Started Collecting Library of Slicer Build number vs. functional modules and extensions.&lt;br /&gt;
Plan for NAMIC project week: scheduled meetings for XNat data customization, Skull-stripping modules tuning, identified Social Cognition study cases that fail EM Segmentation processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 11, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Updating and verification of EM Segmentation Scenario&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Projects:ARRA:SlicerWF:UseCaseScenarios#Usecase_MS_lesion_Assessment&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Familiarizing with Slicer3.4/5 Modules required for implementation of EM Segmentation Scenario. Participation in debugging and/or usage tuning of Dicom Conversion, Registration, Skull Stripping, Masking, and Image Casting modules. &lt;br /&gt;
&lt;br /&gt;
* December 4, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Slicer3.4's EM Segmentation and Visual QC as part of image processing pipeline for Social Cognition Study for MS Patients.&lt;br /&gt;
Project emerged. EM Segmentation template creation debugged.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
Emphysema Measurements (COPD Study) - workflow stability and scalability test.&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 27, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Emphysema Measurements (COPD Study).&lt;br /&gt;
Added compensation for long running calculations and time-outs to the main computing pipeline.&lt;br /&gt;
Visual QC (work in progress)&lt;br /&gt;
** Infrastructure&lt;br /&gt;
XNat data structure customization, metadata storage, results consolidation: new feature request list creation (work in progress)&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 13, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
*** Pilot system for whole processing cycle for Emphysema Measurements (COPD Study) including the following:&lt;br /&gt;
Web query for CT session file list download&lt;br /&gt;
Pilot user interface for submitting the file list and starting processing pipeline&lt;br /&gt;
Notification about processing steps and failures&lt;br /&gt;
Upload results to XNat repository (at this stage results are uploaded into same folder where original scans are(*))&lt;br /&gt;
*** Immediate Plans&lt;br /&gt;
Complete Visual QC module&lt;br /&gt;
Design and implement meta-data transfer to XNat (including processing details and MRML files for loading images into the 3D Slicer)&lt;br /&gt;
&lt;br /&gt;
(*)Customization of results storage&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 6, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Tuned and debugged multiple subjects processing for: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat.&lt;br /&gt;
***Started working on quality control embedding into the above scenario. Plan to complete and video-record demo next week.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***Published general Product Integration scenario flow chart to collaborators' community. Discussion is open and in progress&lt;br /&gt;
&lt;br /&gt;
* October 30, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Piloted and tested the sequence: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat(1).&lt;br /&gt;
***Performance test of overall cycle: data transfer from remote serve is a bottleneck as expected&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data browsing features reviewed.&lt;br /&gt;
(1) Not automated yet&lt;br /&gt;
* October 23, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Defined COPD processing scenario with interoperability between Xnat, 3D Slicer Command Modules, Workflow, and Gridwizard Enterprise.&lt;br /&gt;
***Pilot version of Emphysema Measurements workflow pipeline deployed.&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data transfer features reviewed. Use account at XNat Central during learning curve.&lt;br /&gt;
***Feasibility test of 3D Slicer fiducials module for ROI highlights during QC and manual image processing activities. &lt;br /&gt;
* October 16, 2009&lt;br /&gt;
**Lung CT Scans Processing. Pilot project emerged. GenerateEmphysemaMeasurements module deployed as a webservice that submits jobs to computational cluster.&lt;br /&gt;
**EM Segmentation. Familiarized with GUI steps. Started working on automation steps outlining&lt;br /&gt;
**3D Slicer and XNat interaction. Got an overview from Wendy Plesniak.&lt;br /&gt;
* October 1 - 7, 2009&lt;br /&gt;
**Selected two first priority Projects: EM Segmentation of brain MRI images; Lung CT Scans Processing (COPD Study)&lt;br /&gt;
**Got initial outline of user requirements and design specs&lt;/div&gt;</summary>
		<author><name>Azaitsev</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=70521</id>
		<title>Projects:ARRA:SlicerWF</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=70521"/>
		<updated>2011-08-22T13:45:33Z</updated>

		<summary type="html">&lt;p&gt;Azaitsev: /* Progress */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Projects:ARRASuplements|Back to Slicer ARRA home page]]&lt;br /&gt;
= Aim =&lt;br /&gt;
Supplement 3D Slicer and Extensible Neuroimaging Archive Toolkit (XNAT) with workflow management system. Provide integration and interoperability between 3D Slicer, XNAT Services and 3-rd party image processing applications and high performance computing systems. Implement it as within currently developed Structural Planning and Implementation in Neurological Exploration (SPINE) System.&lt;br /&gt;
&lt;br /&gt;
= SPINE Project Documentation =&lt;br /&gt;
[http://cni.bwh.harvard.edu/projects/spine/index.html SPINE Docs]&lt;br /&gt;
&lt;br /&gt;
= Presentations =&lt;br /&gt;
* Segmentation Workflow. PECS University Social Cognition Study.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:SlicerWF_NAC_PECS_Workflow.pdf]]&lt;br /&gt;
* EAB10_ARRA Annual Progress Report Slides.&amp;lt;br&amp;gt;&lt;br /&gt;
[[media:EAB10_ARRA_WF_2011_Zaitsev.ppt | Service Oriented Solutions for 3D Slicer. EAB10_ARRA_WF_2011. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:EAB10_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:NAMIC_ARRA_WF_2011_Zaitsev.ppt  | NAMIC Annual Report 04/2010-03/2011. NAMIC_ARRA_WF_2011_Zaitsev. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:NAMIC_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:Slicer_WF_Slicer4CARMAWorkflow.ppt  | CARMA Workflow. Cardiac Ablation Followup. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:Slicer_WF_Slicer4CARMAWorkflow.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* CARMA Project Beta release Demo Location: http://cni29.bwh.harvard.edu/SlicerWFDemo/index.php&lt;br /&gt;
&lt;br /&gt;
* Segmentation Workflows: Screenshots, scans' and study description : [[File:SlicerWF_EMSegmentProjectsReview.zip]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
= All Hands Meeting Pages =&lt;br /&gt;
* MIT 2011 Summer:&lt;br /&gt;
 Workflows Project [http://www.na-mic.org/Wiki/index.php/Summer_project_week_2011_Workflows_SOA MIT_2011_WorkFlow]&lt;br /&gt;
 Segmentation Project (MS Lesions)[http://www.na-mic.org/Wiki/index.php/2011_Summer_Project_Week_Customizing_EMSegmenter_pipelines_for_brain_lesions MIT_2011_LesionsSegmentation]&lt;br /&gt;
* Salt Lake City 2011 Winter [http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA SLC_2011_WorkFlow]&lt;br /&gt;
* MIT 2010 Summer [http://wiki.na-mic.org/Wiki/index.php/Summer_project_week_2010_Workflows_SOA MIT_2010_WorkFlow]&lt;br /&gt;
&lt;br /&gt;
= Research Plan =&lt;br /&gt;
*Create a stand-alone SPINE desktop agent with fully functional data exchange and communication mechanisms towards 3D Slicer and XNAT.&lt;br /&gt;
*Develop Service Oriented Architecture (SOA) SPINE System that will include 3D Slicer image processing modules deployed as web services as well as a workflow management system to orchestrate interaction between 3D Slicer, XNAT, and 3-rd party tools.&lt;br /&gt;
*Implement two-way control and communications between 3D Slicer and SPINE modules.&lt;br /&gt;
*Adapt SPINE System for cluster and grid computing scenarios.&lt;br /&gt;
*Provide with workflow and 3D Slicer web service wrappers editing tools.&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:UseCaseScenarios| Use Case scenarios]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PETCTWorkflow| PETCTWorkflow]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:AgingStudySegmentation| AgingStudySegmentation]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:TwoTensorTractography| TwoTensorTractography]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:LongitudinalMultimodalityRegistrationSuite| LongitudinalMultimodalityRegistrationSuite]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:MigrationJavaClients2QT| MigrationJavaClients2QT]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PediatricMSSegmentation| PediatricMSSegmentation]]&lt;br /&gt;
*[[DBP3:Utah:RegSegPipeline| MRI-based study and treatment of atrial fibrillation]]&lt;br /&gt;
&lt;br /&gt;
= Application Server / Workflow Engine Downloads =&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:WFEngineDownloads| Download Links]]&lt;br /&gt;
&lt;br /&gt;
=Key Personnel=&lt;br /&gt;
* Charles Gutmann, MD., 4%,  9-17-2009 through 9-16-2011&lt;br /&gt;
* Alexander Zaitsev, Ph.D., 75%, 9-17-2009 through 9-16-2011 &lt;br /&gt;
&lt;br /&gt;
=Annual Progress Statements =&lt;br /&gt;
'''2010-11''' &amp;lt;br&amp;gt;&lt;br /&gt;
The  April 2011 – March 2011 period was devoted on developing portable workflow solutions that can be deployed on end-users' workstations or notebooks with minimal or no system administration activities. This is in contrast to the server-side deployment. The following scenarios had been deployed and used for actual projects that require the following types of workflows: PET/CT registration and computation of biomarker driven brain physiological activities, Brain MRI Images segmentation,  MRI and MRI Angiography images pre-processing for cardiac ablation outcome estimation. Some  workflows (like EM Segmentation) had been utilizing various scenarios, some research projects  (like evaluation of chemotherapy outcome) require two types of workflows to assess physiological and structural changes. Starting from the 4th Quarter of 2011, the migration project had been emerged in order to embed Workflow GUIs into newly developed Slicer4 Suite. The existing rich client Java GUI applications are being re-written as C++/QT Sliceletts units, new modules (such as cardiac ablation project support) are had been written from scratch. The latter are being deployed from the Slicer4 GUI and act at a liaison between Slicer4 and Application Server containing  workflow and Slicer modules deployed as services. The feedback from the end users indicates that Workflow approach for the complex processing improves productivity, aids to the processing standardization and contributes to the overall experience using 3D Slicer&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
=Quarterly Progress=&lt;br /&gt;
&lt;br /&gt;
* '''2d Qtr, 2011''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study: Second release deployed. &lt;br /&gt;
*** End-users completed the first Project and currently analyzing SUV values and clinical data&lt;br /&gt;
*** New features added: Human Brain Hemispheres segmentation, Scull-stripping for total SUV counts calculation, Flexibility of custom designed label look-up table usage (users can define ROI notation according to the Project needs)&lt;br /&gt;
&lt;br /&gt;
** Left Atrium Ablation Assessment (CARMA Project)&lt;br /&gt;
*** Completed workflow pipeline for automated pre-processing and manual intervention&lt;br /&gt;
*** Developed front-end GUI for the CARMA Project support in Slicer4.&lt;br /&gt;
*** Run the workflow with the end users during NAMIC Project Week&lt;br /&gt;
*** Evaluated feasibility of left atrium wall and post-ablation scar segmentation using Robust Statistical Segmentation (RSS). Identified necessary processing controls with RSS module designers&lt;br /&gt;
&lt;br /&gt;
** Multiple Sclerosis CLIMB Study&lt;br /&gt;
*** Reprocessing for lesion segmentation&lt;br /&gt;
*** Developed Web-based (Java EE 6) application for submitting cases to the workflows for EM Segmentation of MPRAGE and registration to PD/T2/FLAIR images (60% completion)&lt;br /&gt;
&lt;br /&gt;
** EM Segmentation: &lt;br /&gt;
*** Upgraded EM Segmentation services to Slicer 3.6.4&lt;br /&gt;
*** Added brain hemispheres segmentation module to the workflows (used for PET/CT Longitudinal study)&lt;br /&gt;
*** Work with EM Segmenter module developers on building pipelines for white matter lesion segmentation (work in progress)&lt;br /&gt;
&lt;br /&gt;
** Plans for the 3rd quarter&lt;br /&gt;
*** Migrate CARMA Project workflow to end-users&lt;br /&gt;
*** Packaging of Slicer4 Workflow modules and Slicer4 custom build distribution &lt;br /&gt;
*** Completion of Web-base segmentation and registration suite&lt;br /&gt;
*** Users and Developers Documentation&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* NAMIC Annual Progress Slides (April 2010 - March 2011):&lt;br /&gt;
&lt;br /&gt;
* '''1st Qtr, 2011''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study: Second release is under testing by end-users. &lt;br /&gt;
*** Added MRI registration to aid ROI drawing on PET scans&lt;br /&gt;
*** Improved SUV results reporting and added flexibility to update ROI lookup table&lt;br /&gt;
*** Automated EM Segmentation of MRI images for computing SUVs for white matter, CSF, and whole brain (80% completion)&lt;br /&gt;
*** Integration with SPECTRE scull stripping module (70% completion) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** EM Segmentation: Automated WF Pipelines are created &amp;lt;br&amp;gt;&lt;br /&gt;
*** Flexible atlas selection (Pediatric, etc) feature added&lt;br /&gt;
*** Workflows implemented for EM Segmenter 3.6.2 and 3.6.3 (1st Qtr 2011 release)&lt;br /&gt;
&lt;br /&gt;
** Cardiac ablation results follow-up: Workflow for registration and ROI selection of cardiac MRI and MR Angiography &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Wrokflow and Web Services for prospective DTI tractography modules (currently written as Matlab modules at PNL) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Web Services for SPECTRE Scull stripping module&lt;br /&gt;
*** Accuracy and performance tuning&lt;br /&gt;
*** 50% completion&lt;br /&gt;
&lt;br /&gt;
** Migration Front End GUI to Slicer4/QT:&lt;br /&gt;
*** EM Segmentation&lt;br /&gt;
*** Cardiac Ablation Study&lt;br /&gt;
&lt;br /&gt;
** DICOM Uploader and Desktop Browser for XNat Image repository (alpha version - tested for MGH MS Center studies, proposed to use with MI2B2 Clients and Services)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''4th Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study and EM Segmentation for Aging Study are deployed at end-user sites and actively used for research. &lt;br /&gt;
** Adopted EM Segmentation preprocessing pipeline for HIV Study: high resolution SPGR images, integration with FreeSurfer brainmask extraction outputs; integration of Slicer SPECTRE module for brainmask extraction is in progress.&lt;br /&gt;
** The following post-release upgrades had been implemented based on end-user feedback: Application Server basic controls are performed from Rich Client GUI as alternative to traditional IT administration activities. The controls are implemented on point-and-click bases and include web services and workflow application deployment and upgrades, application server start and stop as well as warning end user when the server is not accepting request.&lt;br /&gt;
** Added DICOM downloads and results uploads of PET/CT pipelines from and to XNat Repository&lt;br /&gt;
** Created Services and Workflow for Matlab Prototypes modules. Case Study: tractography for DTI images&lt;br /&gt;
** Extended XNAT integration services:&lt;br /&gt;
*** Browsing capabilities of XNat data repository from the Workflow Applications&lt;br /&gt;
*** Improved DICOM upload and download performance&lt;br /&gt;
*** Added Metadata organizing services for uploaded DICOM images: header data extraction, image snapshots creation. &lt;br /&gt;
** Started project for Rich Client GUI migration from Java desktop application to build into SLicer4 QT modules. This affects mostly front-end GUI and has the following approaches: distribution with the Slicer4, end-user will select desired workflow application from Slicer4 menu while QT-written modules provide with the same functionality as Java Rich Clients. Case Study for the Migration process: registration suite for longitudinal studies that include multi-modality images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* '''3d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Concentrated on building downloadable workflow applications that could run both in desktop (new) and server environment, and that require minimum IT administrative resources. The desktop deployment is in compliance with Slicer3 general deployment concept.&lt;br /&gt;
*** The following use case scenario had been chosen: PET/CT image processing for longitudinal studies, EM Segmentation for longitudinal Aging Study.&lt;br /&gt;
** Released workflow application for PET/CT image processing for longitudinal studies. Provided end users with training and documentation.&lt;br /&gt;
*** The PET/CT processing workflow was designed to be a general application used whenever both structural patterns and metabolic activities are within the research scope. &lt;br /&gt;
*** The desktop version is tuned to use minimal computer resources, so the automates processing instances do not interfere with human activities. Automated activities may include, for example, registration and PET scan's standard uptake values computing, and manual human activities may include image cropping, quality control, and labeling voxels of interest.&lt;br /&gt;
** Core services and EM Segmentation preprocessing workflow was build for retrospective Aging Study. Tuned the Slicer3 webservices for processing low grade images acquired in mid 90s. Entire workflow is implemented with Slicer3 only modules and can be deployed locally and on the servers. Usage of Service Oriented Architecture (SOA) as a core technological approach allowed reusing most of the web services that had been build for PET/CT project. &lt;br /&gt;
** Continued embedding Slicer3 application and modules into previously released processing pipelines: replaced MIPAV with Slicer3 GUI for lesion assessment step in the multi-center Pediatric MS Cohort image processing &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''2d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Completed Social Cognition Workflow Implementation. This includes EM Segmetnation pre- and post-processing pipelines, data tracking, and integration with 3d party image processing utilities, as well as processing results acquired manually with Slicer GUI.  &lt;br /&gt;
** Multi-modality image registration and ROI selection/alignment workflow for longitudinal studies. &lt;br /&gt;
*** Use case: PET/CT image processing for longitudinal studies. &lt;br /&gt;
*** Build portable library of Slicer modules as web services and workflow that are deployed and run on a end-users' worksatations without utilization of SPL and other servers. The web services include novel Slicer3 modules, such as BRAINSFit and BRAINSResamle &lt;br /&gt;
*** Started working with Slicer3 developers on Slicer 3.8 GUI wizard to communicate with workflow instances.&lt;br /&gt;
** Participated at NA-MIC Summer 2010 Project Week: [[Summer_project_week_2010_Workflows_SOA]]&lt;br /&gt;
&lt;br /&gt;
=Progress=&lt;br /&gt;
* August 19, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation&lt;br /&gt;
* Deployed first release (Human Brain EM Segmentation) web request application&lt;br /&gt;
* End-users requested EM Segmentation of MS lesion on PD images (feasibility is being evaluated with EM Segmenter Team)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
3D Slicer WF. General&lt;br /&gt;
* Preparation of 3D Slicer and WF Modules presentation for MGH&lt;br /&gt;
&amp;lt;br&amp;gt;  &lt;br /&gt;
&lt;br /&gt;
* August 12, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
* Migrating build to updated Slicer4 environment  (PythonQT and new added module dependencies issues)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation&lt;br /&gt;
* Tested and reviewed EM Segmentation web app on end-users' data&lt;br /&gt;
* Updated workflow, so EM Segmentation is performed on T1 after registration to T2 or FLAIR. This gives more accurate results comparing to segmentation of high resolution image followed by resampling (have to use nearest neighbor interpolation to retain actual label values) of label map &lt;br /&gt;
&lt;br /&gt;
* August 5, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT&lt;br /&gt;
* Follow-up with end users with new Study setup&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
CARMA Project&lt;br /&gt;
* Documentation (Work in progress)&lt;br /&gt;
* Plans for next week: custom packaging (Mac Snow Leopard 64 bit), building extension, documentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation&lt;br /&gt;
* Stress-test of online segmentation requests suite for  [http://www.slicer.org/slicerWiki/index.php/EMSegmenter-Tasks#Additional_Use_Cases CLIMB Study](for BWH MS Center)&lt;br /&gt;
* Reason for building online suite: the Group is Using mostly MAC OS Tiger machines for legacy reasnos, the most recent Slicer3 builds as well as QT don't work on those machines (QT4.x runtime could not be installed).&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* July 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA Project&lt;br /&gt;
* Documentation (Work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation&lt;br /&gt;
* Work on alpha-release of online submission of segmentation requests (for BWH MS Center)&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* July 22, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
Vacation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* July 8, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
3D Slicer in General and CARMA Project&lt;br /&gt;
* Presentation and life demo at Cardiology Research Center (Moscow, Russia) [[File:RussianCardiologyCenterCARMA2011.ppt]]&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* July 1, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA V1.0&lt;br /&gt;
* Migration to new QT building environment (Mac 10 Snow Leopard). &lt;br /&gt;
* Building custom package. Issues: new features (not only WF related) are not shown on the menu of the resulting application&lt;br /&gt;
* Comparing preprocessing workflow results with published in literature data (our module produces better alignment)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*June 24, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
Project Week:&lt;br /&gt;
* Testing RSS module for left atrial wall scar segmentation&lt;br /&gt;
* Testing EM Segmenter for lesion detection on PD (requested by end-users) and FLAIR images&lt;br /&gt;
&lt;br /&gt;
EM Segmentation &lt;br /&gt;
* Web-based segmentation and registration module for MS Center. Goal: facilitate 3D SLicer modules for the cases that could not be processed with in-house build DTS+ algorithm&lt;br /&gt;
* Pipeline: Segment MPGR or T1 (user's choice), Register MPGR to PD/T2, Resample Segmentation Map to PD/T2. Completion: 60-70%.&lt;br /&gt;
* The rest will be done manually or via lesion segmentation with EM Segmenter.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* June 17, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
Preparation for Project Week&lt;br /&gt;
&lt;br /&gt;
* June 10, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
CARMA V.1.0&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code completed and tested&lt;br /&gt;
* Packaging as extension is pending (Subject for Summer 2011 Project week)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Debugging consolidation results issue(SUVs for manual and automated segmentation) &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* June 3, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Deployed on end-user's machine&lt;br /&gt;
* TODO next week: fix SUV results consolidation issue (when MRI segmented ROI got SUV computed for some subjects, only those subjects' SUVs are being added into consolidated report. &amp;quot;Raw&amp;quot; SUV values per subject are generated as expected)  &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 27, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Ready for deployment. New Features: hemispheres EM Segmentation, automated ICC/brainmask extraction using EM Segmenter, fixed controls for MRI conversion and registration&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 20, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General / PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Hemispheres EM Segmentation - adjusted for required label lookup table&lt;br /&gt;
* Use cases added for EM Segmenter General Project: http://www.slicer.org/slicerWiki/index.php/EMSegmenter-Tasks#EMSegmenter_use_cases&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SPECTRE Scull Stripping&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* The new version to be tested on coming week (After PETCT MRI processing migrated to Hemispheres scenario )&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* May 13, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General / PETCT V1.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Hemispheres EM Segmentation - technically works with labal values hardcoded in Slicer EM Segmenter - need to add manual label value edition step&lt;br /&gt;
* PETCT WF Cut for Java GUI (Pending Hemispheres label update completion). Next release will be in QT4.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* May 6, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (QA of EM Segmenter module, work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* April 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Open Discussion for Packaging WF QT Modules as Slicer4 extensions (waiting for SOPs)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review supported projects http://wiki.na-mic.org/Wiki/index.php/File:SlicerWF_EMSegmentProjectsReview.zip &lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (required by Study)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Slicer Modules General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Standardizing Crop Volumes Output (with A. Fedorov's module). Review for required updates of existing product (PET/CT, CARMA)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Open Discussion for Packaging WF QT Modules as Slicer4 extensions (waiting for SOPs)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review supported projects http://wiki.na-mic.org/Wiki/index.php/File:SlicerWF_EMSegmentProjectsReview.zip &lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (required by Study)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Slicer Modules General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Standardizing Crop Volumes Output (with A. Fedorov's module)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 22, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Beta release ready. Demo Location: http://cni29.bwh.harvard.edu/SlicerWFDemo/index.php&lt;br /&gt;
* TODO: Tutorial. Original inputs copy/renaming&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 15, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Adding App server auto-config features&lt;br /&gt;
* Finalizing the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 08, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Second release beta build tested on cosutmer side &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review registration quality (with Dr. Meier). Angiography images' Resampling tuned. &lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 01, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the second release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
XNat Integration&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* (Java) GUI for Project Browsing and DICOM Series Upload. Post-upload DICOM processing tested and debugged&amp;lt;br&amp;gt;&lt;br /&gt;
* Ready for integration with mi2b2 client.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Migrated to Latest Slicer 3.6.3 stable release: only the Input scene had to be updated, the API remained the same&lt;br /&gt;
* Tested EM Segmenter with CMTK4Slicer extension - processing takes to much time on Linux_64bit machine, rolled back to BRAINSFit registration. When used on Mac OS X build, the Slicer could not start (bug report 1126).&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SPECTRE Scull Stripping:&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Testes for various use cases: the module is extremely sensitive to T1 MRI quality (does not work for most MRIs from PET/CT project&lt;br /&gt;
* TODO next week: check for FLAIR images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Slicer4 QT GUI and Cropping activity in progress.&amp;lt;br&amp;gt;&lt;br /&gt;
* Tried direct MRA to MRA registration option: resampling with LMRI registration transforms works better.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Extra VOI labels revised&lt;br /&gt;
* Debugging of SUV results' renormalization step&lt;br /&gt;
* TODO: ICC extraction / whole brain total uptake computing; EM Segmentation for R_WM, L_WM SUV computing and BPH estimation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SCULL STRIPPING/SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Installed and tested CLI option on Linux_64bit platform&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Workflow interruption before BSPline registraton: BPEL Module completed. Slicer4 QT GUI and Cropping activity in prorgess.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Implemented and Tested with end-users proposed changes: denormalization of SUV results, adding more VOI labels, added FLAIR MRI in addition to T1s for VOI drawing&lt;br /&gt;
* Tested manual ICC extraction using PET scans: works satisfactory with island removal and cropping followed by threshold level labeling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4&lt;br /&gt;
* Change proposed: interrupt workflow after affine registration and have user crop the VOI. This is to prevent excessive deformations for BSpline registration and resampling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4. User has option to choose the atlas that fits better for the given subject (NOTE: hardcoding must be rewritten for atlas linking)&lt;br /&gt;
* PETCT test - the problem is that T1s are low resolution and with contrast. Proposed using T1s without contrast&lt;br /&gt;
* PETCT change request: users wants to compute SUV for entire ICC. Had demo how to segment brainmask/ICC using PET scan. The derived brainmask label can be used for SUV computation.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - cmpleted&lt;br /&gt;
* Sample cases run - excessive deformation after BSpline registration hase&lt;br /&gt;
* Next week plan - pull tuning controls to front-end of pipeline API, start working of QT module for CARMA registration&lt;br /&gt;
* May consider other than BRAINSFit registration modules&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Design plan for change request: more VOI labels, add FLAIR in addition to T1 for VOI drawing, T1s segmentation&lt;br /&gt;
* Tested segmentation for sample cases - artifacts from poor quality MRIs lead to exclusion of parts of ICC from segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Completed troubleshooting of EMSegmenter module calling from Java (need TCL libs to be pulled from Slicer environment)&lt;br /&gt;
* Tested EMSegmenter autoruns for HIV and Pediatric MS patiens. Work as expected, subject to improvement of PED MS case segmentation by building better skull/neck/air atalses&lt;br /&gt;
* Suggested usage of two subsets of atalases: with and without neck. The Subject MRIs have to be cropped accordingly or best fit atlas has to be selected&lt;br /&gt;
* Made no-neck cropped atlas collection for default EMSegmenter scenario&lt;br /&gt;
* Tested with PET/CT study MRI cases - see above &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - in progress&lt;br /&gt;
* Next week goal - have back end processing ready&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Longitudinal Study&lt;br /&gt;
* Added MRI registration to the pipeline&lt;br /&gt;
* Troubleshooting of complex XML schema issues on Linux machines (some modules working on MAC do not work on Linux). As a workaround - did not include MRI convert and register part into base BPEL module. Used separate services (transparent for end-user)&lt;br /&gt;
* TODO next week for change request completion: explicit pixel type casting for MRI in BRAINSFit, VOI MRML scene update (currently MRI added on top of schema)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* February 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipeline for Pediatric MRI. Same scenario as for HIV Project, icbm pediatric atlases (Completed, verified)&lt;br /&gt;
* Collected NIH healthy brain development atlases: various age ranges from 4.5 to 18 yo. Converted to Slicer readable format &lt;br /&gt;
* Work on web services for the new automated EM Segmenter module (release Nov 10 - current). Verified task completion both for adult and pediatric images. Discussed tuning parameters for work load balance on workstations.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Started working on MRI registration to the reference CT scans. &lt;br /&gt;
* Design specs for optional White Matter segmentation for SUV computing.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* February 4, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipelines for Pediatric MRI (in progress)&lt;br /&gt;
* Adapting Pediatric T1 atlases for &amp;quot;Human Brain&amp;quot; build-in EM Segmentation wizard (in progress)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 28, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Verifying EM Segmenter module for latest builds and HIV/PED MS Studies (report pending)&lt;br /&gt;
* Work with SPECTRE module developers with pediatric MRI brainmask extraction&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* January 21, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Compiling plan for WF FrontEnd GUI migration to Slicer4/QT Widgets&lt;br /&gt;
* Preparing for annual progress report&lt;br /&gt;
&lt;br /&gt;
* January 14, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI: Integrated into the Slicer4 as Slicelet (or thin Client)&lt;br /&gt;
* Participation at AHM-2011, discussing integration of SPECTRE module and updated approach to EM-Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA&lt;br /&gt;
&lt;br /&gt;
* January 7, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* HIV project workflow delivered. Major additions relate to user convenience: &lt;br /&gt;
- Project-specific parameter settings, importing T1s and brainmasks from FreeSurfer outputs with conversion to NIFTI, resampling brainmask to original scans and automatied subject addition.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Follow up with end user: need to add MRI scans, if available, addition and registration to CT in order to ease VOI drawings.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
 &lt;br /&gt;
* December 31, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Follow-up with user Experience for AGING Study Segmentation (Positive feedback)&lt;br /&gt;
* Target date for HIV project delivery - next week&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Self-training for QT widget development&amp;lt;br&amp;gt;&lt;br /&gt;
* Outlined Workflow Rich Clients migration strategy from Java to QT/Slicer4:&amp;lt;br&amp;gt;&lt;br /&gt;
** Use Java Stubs (similar to SPECTRE integration) or file binding for envocation of workflow pipelines. (See SOAP remark below)&lt;br /&gt;
** Direct Web Servisec calls must be wrapped into REST protocol. The reason: NON-commerchial QT kit does not include SOAP protocol for web servises.&lt;br /&gt;
** The GUI will be implemented as page widget or QT dialog GUI forms called from within Slicer4.&lt;br /&gt;
** Communications between Slicer4 and WF GUI will be set via child-parent and signal-slot relations&lt;br /&gt;
* Worked on a Prototype for Basic EM Segmentation QT widget (70% complete). Will work on integrtion with SLicer4 during the AHM-2010&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
XNAT Integration&lt;br /&gt;
* Debugged XNAT RESTFul API usage for uplaoding DICOM series followed by header data extraction and image snapshots creation&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Added compensation for failed atlas registration (subject for old poor quality pseudo-T1 images): blank probability maps are created in case of failure.&lt;br /&gt;
* Data preparation module for FreeSurfer data import near completion. Expected time for deployment at end-users workstations - first week of January&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Discussed strategy for EM Segmentation pipeline solutions collection (K. Pohl, R. Kikinis)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* RE-using the same core workflow as for 1-channel EM Segmentation of AGING STUDY cases&lt;br /&gt;
* Added data input preparation module: ICC label mask preparation and skull-stripping based on FreeSurfer brainmask output volume.&lt;br /&gt;
* Two-channel EM segmentation pipeline (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE / GENERAL Development &amp;lt;br&amp;gt;&lt;br /&gt;
* Worked on plans for migrating fro rich workflow Java clients to embedded workflow windows inside the Slicer.&amp;lt;br&amp;gt;&lt;br /&gt;
The embedded workflow management clients are to be implemented with QT/PyQT toolkits&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
INTEGRATION WITH XNAT:&amp;lt;br&amp;gt;&lt;br /&gt;
* Automated DICOM series upload with triggering DICOM headers parsing at XNat site (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress. &lt;br /&gt;
- Results upload to XNat (Completed) &amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat based on user's input (Project + Subject + PET or CT session / scan) (Completed)&amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat - perfomance boosting solution for downloads found , web services services are created, relinking for the client side in progress &amp;lt;br&amp;gt;&lt;br /&gt;
- Xnat querying for subjects and automated subject addition into the workflow (In Progress) &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-segmentation module added for auto correction of segmentation results. Particularly - relabeling CSF voxels segmented as Air inside the intracranial cavity. This was requested by end-users after processing images with zero-signals in CSF voxels &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting automated dual-echo DICOM images conversion and split into two NRRD volumes&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT / EM Segmentation pipeline:&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting memory allocation issues for scull-stripping module SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
COPD Project:&amp;lt;br&amp;gt;&lt;br /&gt;
* Benchmark test for accelerated DICOM downloads from XNat (remoote XNat Central server): we can handle at least 6 cases (4 CT scans in each) per hour, which is compatible with current workload quotes on SPL cluster processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* December 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Deployed Version 1. &amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Test project chosen as a closest match to registration scenario: Pediatric MS Cases from MGH - requires periodic image preview for different &lt;br /&gt;
modalities taken from vaious time points. Label maps for VOIs resampling is also required.&lt;br /&gt;
&lt;br /&gt;
* November 26, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user. Version 1 is complete&amp;lt;br&amp;gt;&lt;br /&gt;
* Started working on integration with XNat&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on input data organizing modules&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 19, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user (70% done)&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Universal Registration Workflow for Longitudinal Studies - design specs in progress&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 12, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Minor tuning to EM Segmentation template as of users' feedback&lt;br /&gt;
* Users started using the workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed input data conversion from Genesis to Slicer native or NIFTI format. Our help may be needed in input data organizing.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Tuned application according to co-laborators (PNL) needs&amp;lt;br&amp;gt;&lt;br /&gt;
* The webservices and BPEL workflow application are tested ready to accept computation requests from PNL case tracking system &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Discussed Universal Registration Workflow for Longitudinal Studies&lt;br /&gt;
* Started the thread about possible cooperation with Children hospital's image processing pipelines and integration with Xnat &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 5, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Webservices and workflow pilot project created and deployed on Psychiatry Neuroimaging Laboratory subnet &amp;lt;br&amp;gt;&lt;br /&gt;
* The V.1.0 deployment is scheduled for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 29, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Most of functionality is completed. Some volume statistics post processing is pending&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL EM SEGMENTATION Pipeline: &amp;lt;br&amp;gt;&lt;br /&gt;
* The SPECTRE scull stripping module. Started integration into EMS workflow. Made some test runs from Slicer GUI&amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Identified as a candidate for Workflow Application&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 22, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* All back-end functionality are implemented&amp;lt;br&amp;gt;&lt;br /&gt;
* EM Segmentation scene usability is confirmed by end-user&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for next week: add Label Statistics computation for CSF/Brain/ICC &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 15, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* The latest (October) builds of Slicer 3.6.2 produced acceptable results. This was verified by the target users. The EM Segmentation will be performed on Slicer 3.6.2 or later&amp;lt;br&amp;gt;&lt;br /&gt;
* The new Web services had been created and added to the pipeline as optional processing steps: Biasfield correction (implement novel N2ITKBiasFieldCorrection module) and Volume's scalar datatype casting (as workaround for Biasfield correction module not preserving image scalar datatype - the bug is filed) &amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed the Front-End GUI design with target users. The design pattern is taken from the PETCT project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 8, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-deployment support. Tuned CT registration as of user's feedback.&lt;br /&gt;
* Adapting to the Single Slicer build: Slicer 3.6.2. Found label duplicates in the label lookup table - will ask user if it's tolerable. Waiting for the Slicer 3.6.2 build that contains all required modules. Rolling back label tag appending code for SUVs - the latest Slicer build appends the tags.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Resumed development. The priorities are set for usage of Slicer 3.6.2 - subject for EM Segmentation scene tuning. Continued coding for Scene creation for Slicer 2.8 - as a backup option for ongoing research project.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 1, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized V1.0 release based on end-user feedback: updates relate mostly to error proofing and SUV values representation&lt;br /&gt;
* Post-deployment support. Users pre-processed first set of patients &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* September 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* System deployed and tested at End Users' site.&amp;lt;br&amp;gt;Users are trained to perform all tasks required by the workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
* Got positive feedback with suggestions on Slicer Scenes' layouts improvement and PET scans' SUV (standard uptake values) results display&lt;br /&gt;
* Two distribution packages are assembled: Lunix and MAC OS versions. The difference in two packages is in specific Slicer3.6/3.7 builds - subject to Slicer Linux builds debugging.&amp;lt;br&amp;gt; As a workaround for Linux deployment - multiple Slicer builds are used to perform various tasks (registration, opening editing scenes in Slicer, SUV computing)&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for coming week - finalize V1.0 release based on end-user feedback&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Embedded SUV computations into the workflow (as system calls - will be translated into web service later)&amp;lt;br&amp;gt;&lt;br /&gt;
* Pre-release demo for end users.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Create and debug EM Segmenter scenes template for Slicer 3.6 and 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* September 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation - workflow pipeline and deployment verified&amp;lt;br&amp;gt;&lt;br /&gt;
* Tested EM Segmentation scenes within Slicer 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
* Started migration of EM Segmentation to Slicer 3.6. Discovered issues had been reported to EM Segmenter module designers &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* August 29 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation completed. Preprocessing Pipleine completed 80% (subject for input registration parameters tuning) &amp;lt;br&amp;gt;&lt;br /&gt;
* Most webservices (for registration and resampling steps) had been taken and re-used from PET/CT ROI/Longitudinal Study - showing the advantage of service-oriented software design and deployment.&lt;br /&gt;
* Continued on distribution and deployment of the service/workflow applications: on PET/CT and AGING STUDY projects.&lt;br /&gt;
&lt;br /&gt;
PEDIATRIC Multiple Sclerosis Cohort. Support of multi-center distributed processing project&amp;lt;br&amp;gt;&lt;br /&gt;
* Introduced Slicer 3.6 for the MS Lesion Assessment step performed at Mayo Clinic. Images are being transferred from image repository at BWH and automatically opened and arranged within Slicer GUI for reading.  This was replacement of Client GUI using MIPAV that stopped working on new computers at Mayo Clinic.&lt;br /&gt;
The images are being loaded via generated MRML Scenes same way as in PET/CT and AGING STUDY projects &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* August 22 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Preprocessing pipeline merge with SUV computations &amp;lt;br&amp;gt;&lt;br /&gt;
- QA for SUVs computation was performed by Wendy Plesniak for images with known uptake values. &amp;lt;br&amp;gt;&lt;br /&gt;
- Discovered that image cropping step (not related to automated registration pipeline and SUVs computing) smoothes the images by doing interpolation when used with default settings. Got suggestions from Steve Piper using Nearest-Neighbor interpolation (&amp;quot;no interpolation&amp;quot;) for a time being&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
- This is the new project candidate. Requested for the images with failed manual segmentation and/or segmentation with FreeSurfer. The EM Segmentation run showed most acceptable results on one of the problem images back in February &amp;lt;br&amp;gt;&lt;br /&gt;
- The workflow will be developed and deployed similar to PET/CT ROI Longitudinal study approach - all preprocessing steps will be done with Slicer modules, all runs will be performed on local end-user machines.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
 &lt;br /&gt;
&lt;br /&gt;
* August 15 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- First 5 cases with 3-4 time points preprocessed for SUVs computation&lt;br /&gt;
&lt;br /&gt;
* August 8 2010&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Testing of installation and operation at users' site (Performed by Wendy Plesniak)&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* July 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Delivered beta version of registration pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
- Prepared installation and user manuals &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* June 11, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Registration modules completed &amp;lt;br&amp;gt;&lt;br /&gt;
- Irregular cases registration problem solved (when whole body and brain only scans are mixed for a timepoint)&amp;lt;br&amp;gt;&lt;br /&gt;
- Live demo of case setup and registration workflow for end users. Real case with 4 timepoints used&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Coming week plans&amp;lt;br&amp;gt;&lt;br /&gt;
- Adjust workflow based on end users' feedback&amp;lt;br&amp;gt;&lt;br /&gt;
- Integration with SUVs computing for PET scans&amp;lt;br&amp;gt;&lt;br /&gt;
- GUI for workflows dispatching and data organizing&amp;lt;br&amp;gt;&lt;br /&gt;
- (TBD) Integration with 4D time series analysis Slicer module&amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
* May 28, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- Migration to the latest Slicer 3.6 release candidate &amp;lt;br&amp;gt;&lt;br /&gt;
- Added webservice for new registration module: BRAINSFit &amp;lt;br&amp;gt;&lt;br /&gt;
- Test runs for new patients with 4 timepoints' scans &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Plans for next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI &amp;lt;br&amp;gt;&lt;br /&gt;
- processing workflow demo for end user &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 21, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Pilot version of portable web services and automated workflow tested: &amp;lt;br&amp;gt;&lt;br /&gt;
Linux: workflow and visual review passed&amp;lt;br&amp;gt;&lt;br /&gt;
Stress test for 25 timepoints passed &amp;lt;br&amp;gt;&lt;br /&gt;
MAC OS: workflow passed, visual review failing when PET/CT images are loaded into GUI simultaneously (bug report submitted)&amp;lt;br&amp;gt;&lt;br /&gt;
Windows: need to adapt command line modules and workflow management system to sygwin environment&amp;lt;br&amp;gt;&lt;br /&gt;
Plans for next week: integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI&lt;br /&gt;
&lt;br /&gt;
* May 7, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Selected registration and resampling modules with more precise and stable outputs. &amp;lt;br&amp;gt;&lt;br /&gt;
Started building portable web services and automated workflow &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 30, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- manual walk through the processing steps: ROI cropping, registration/resampling, PET pharmaceutical DICOM data retention. &amp;lt;br&amp;gt;&lt;br /&gt;
- testing workflow and web services packages distribution to end-users' machines&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* April 23, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : testing various registration and re-sampling algorithms (work in progress)&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation: as of collaborators' request, run existing EM Segmentation workflow for older low resolution pseudo-T1 images. The EM Segmentation works for those images with manual sampling. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 16, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
  Social Cognition Study: started Cortical Thickness Measurement module build (bases on NA-MIC ARCTIC pipeline) &amp;lt;br&amp;gt;&lt;br /&gt;
  PET/CT ROI/Longitudinal Study Registration : Design specs, PET-to-CT images registration tests on training data. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 9, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. GUI update based on end-user experience.&amp;lt;br&amp;gt;&lt;br /&gt;
User request: automated label maps' volumes calculation (Currently possible from Slicer3 GUI)&amp;lt;br&amp;gt; &lt;br /&gt;
PET/CT ROI Project. Initial design specs discussion with end-users and co-developers&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure&lt;br /&gt;
Verification of segmentation workflow GUI: from registering new case to reviewing results&amp;lt;br&amp;gt;&lt;br /&gt;
Cross study test of segmentation workflow: MGH/MS Center data - success,  HIV Project data - some EM Segmentation scene tuning is needed &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*&lt;br /&gt;
* April 2, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. Segmentation workflow completed&amp;lt;br&amp;gt;&lt;br /&gt;
* Coming Week plans:&amp;lt;br&amp;gt;&lt;br /&gt;
- Document Segmentation Workflow. Follow up with end users &amp;lt;br&amp;gt;&lt;br /&gt;
- Start with Cortical Thickness and ROI-in-longitudinal studies workflows&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* March 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All essential processing and workflow interaction clients are ready.&amp;lt;br&amp;gt;&lt;br /&gt;
- Completed segmentation for 10 out of 50 patients. The remaining cases will be finalized upon manual lesion segmentation and QC verification of WM/GM/CSF and Deep GM segmentation's. &amp;lt;br&amp;gt;&lt;br /&gt;
- TODO next week: refine QC GUI and data tracking / progress monitoring schema. &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&amp;lt;br&amp;gt;&lt;br /&gt;
- New Slicer3 web services added: re-slicing with reference image volume, casting image scalar type &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
* March 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Segmentation maps Merging Services for GM/WM/CSF (Slicer EM Segemnter), Lesion (Slicer, Manual), and Deep GM (FreeSurfer)  &amp;lt;br&amp;gt;&lt;br /&gt;
- Deep GM segmentation pipeline adopted as optional service for Social Cognition Study (22 out of 50 cases processed) &amp;lt;br&amp;gt;&lt;br /&gt;
- (In progress) GUI client for Launching Segmentation results merging with optional Deep GM segmentation with FreeSurfer &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- Complete GUI Client for Segmentation result merging &amp;lt;br&amp;gt;&lt;br /&gt;
- Progress Monitoring services for entire Study processing: EM Segmenter Preprocessing, EM Segmentation, Lesion Segmentation (including human activities assignments), Deep GM segmentation, and results consolidation. &amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* March 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All 50 cases went through &amp;quot;basic&amp;quot; One-channel EM segmentation (GM/WM/CSF) &amp;lt;br&amp;gt;&lt;br /&gt;
- Basic pipeline start-up command line client created: user has two options - request brainmask extraction or provide with previously extracted brainmask for a given subject &amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison of GM/WN/CSF performed for Slicer EM Segmenter and FreeSurfer recon-all (used with default settings). &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmenter provides more accurate output &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmentation pipeline runs faster (40 minutes vs 12 hrs when no brainmask extraction requested) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO:&amp;lt;br&amp;gt;&lt;br /&gt;
- merging modules for automatic 1-channel EM segmentation and manual lesion segmentation &amp;lt;br&amp;gt;&lt;br /&gt;
- Emerge Cortical Thickness pipeline project: use NAC ARCTIC processing steps and modules &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Selected stable EM Segmentation scenario: White Matter, Gray Matter, and Cerebrospinal Fluid &amp;lt;br&amp;gt;&lt;br /&gt;
- First 16 cases are segmented for selected scenario. Nine more cases are preprocessed for EM Segmentation.&amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison to segmentation with FreeSurfer showed better accuracy for Slicer2 EMSegmenter &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure &amp;lt;br&amp;gt;&lt;br /&gt;
- Three prerpcocessed cases failed during volume ICC masking with in-house build utility. Evaluated switching to Slicer3 Mask and island removing modules.&amp;lt;br&amp;gt;&lt;br /&gt;
- Initial design specs discussion for cortical thickness measurement pipeline. ARCTIC pipeline selected. ARCTIC preprocessing steps signifficantly overlap with EM Segmentation preprocessing workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
  &lt;br /&gt;
* February 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: &amp;lt;br&amp;gt;&lt;br /&gt;
A) parameters tuning for EM Segmenter itself (work with EM Segmenter developer), template scenes creation &amp;lt;br&amp;gt;&lt;br /&gt;
B) update preprocessing pipeline - deep gray matter atlases included &amp;lt;br&amp;gt;&lt;br /&gt;
C) test and debug preprocesing pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
D) identified missing modules: atlas autocalibration for EM Segmentation scene, Island removal for ICC mask&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- Review currently deployed modules. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: reviewed firts seven subjects' outputs, added volume orientation module into pipeline (prevents ICBM atlas linear registration failures)&amp;lt;br&amp;gt;&lt;br /&gt;
- Fused ICC(brainmask) extraction module with EM Segmenter preprocessing. Three scenarious implemented: start with pre-extracted ICC mask (longitudinal studies case), run with ICC ectration, run with ICC extraction AND ICC correction before ICBM atlas preporcessing. &amp;lt;br&amp;gt;&lt;br /&gt;
- Completion of Human activities GUI (QC, ICC Correction) planned for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: Volume Orientation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: automated preprocessing pipeline for Slicer2 EM Segmenter test version deployed. Seven cases pre-processed.&lt;br /&gt;
- PET Quantitative measurements: Preliminary design specs discussion.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: BSplineRegistration (for non-linear registration), ResampleVolume2 (for atlases resampling based on image atlase templates registration). Local and Network runs are implemented, Cluster/GridWizard implementation pending.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Slicer EM Segmenter module: preprocessing design for Slicer2 EM Segmenter&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Adapting for Slicer2 EM Segmenter (mostly from pipelines and services for previous projects)&lt;br /&gt;
  -- Integration with FreeSurfer modules for bisafield correction, brainmask extraction, and linear registration of ICBM atlases&lt;br /&gt;
  -- Preprocessing updates for non-linear registration of ICBM atlases with Slicer2 (image re-orientation service designed)&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 29, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- EM Segmentaton pipeline: preprocessing results are being transferred to XNat (anonymized data, Central XNat) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Slicer EM Segmenter module: discussed agenda and scheduled a work meeting for Social Cognition Study image segmentation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Testing stage, 95% completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- SPL XNat server: verified data exchange via RESTfull web services.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 22, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Follow up with White Matter Lesion Segmenter and Scull Stripping Modules developers: Work in Progress&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Work in Progress, 60%+ completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Discussed SPINE image repository migration to XNat&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 15, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. &lt;br /&gt;
- Social Cognition Study: &lt;br /&gt;
Work-in-progress on intermediate (reconstruction) and results (resources) data storage at XNat.&lt;br /&gt;
&amp;lt;br&amp;gt;Reviewing and preparation more cases for EM Segmentor (Slicer 3.5) tuning.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* NA-MIC Project Week&lt;br /&gt;
Selecting candidate Slicer modules for other than Lesion EM Segmentation topics of Social Cognition study: Withe Matter Lesion Segmenter (UNC), Scull Stripping utility from UIOWA.&lt;br /&gt;
Reviewing issues of currently used Scull Stripping Slicer Extension and Slicer 3.5 EM Segmenter.&lt;br /&gt;
&amp;lt;br&amp;gt;XNat Data organizing training&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 1, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Preparation of Demo for NA-MIC work week: &lt;br /&gt;
- COPD Study. Added Remote pipepline start interface (represents real world scenario where Xnat repository, Processing modules and User are at different sites)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
- EM Segmentation. Added human activities steps to the workflow: ICC (brainmask) correction and EM Segmantation scena load per se.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 25, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Pilot workflow pipeline for EM Segmentation (all steps except user-activity step: ICC correction assignment and tracking)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 18, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Build and tested web services for EM Segmentation image preprocessing: DICOM-to-NRRD conversion, registration, skull stripping, image masking.&lt;br /&gt;
Started building workflow pipeline (subject to finish first version next week)&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Started Collecting Library of Slicer Build number vs. functional modules and extensions.&lt;br /&gt;
Plan for NAMIC project week: scheduled meetings for XNat data customization, Skull-stripping modules tuning, identified Social Cognition study cases that fail EM Segmentation processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 11, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Updating and verification of EM Segmentation Scenario&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Projects:ARRA:SlicerWF:UseCaseScenarios#Usecase_MS_lesion_Assessment&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Familiarizing with Slicer3.4/5 Modules required for implementation of EM Segmentation Scenario. Participation in debugging and/or usage tuning of Dicom Conversion, Registration, Skull Stripping, Masking, and Image Casting modules. &lt;br /&gt;
&lt;br /&gt;
* December 4, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Slicer3.4's EM Segmentation and Visual QC as part of image processing pipeline for Social Cognition Study for MS Patients.&lt;br /&gt;
Project emerged. EM Segmentation template creation debugged.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
Emphysema Measurements (COPD Study) - workflow stability and scalability test.&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 27, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Emphysema Measurements (COPD Study).&lt;br /&gt;
Added compensation for long running calculations and time-outs to the main computing pipeline.&lt;br /&gt;
Visual QC (work in progress)&lt;br /&gt;
** Infrastructure&lt;br /&gt;
XNat data structure customization, metadata storage, results consolidation: new feature request list creation (work in progress)&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 13, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
*** Pilot system for whole processing cycle for Emphysema Measurements (COPD Study) including the following:&lt;br /&gt;
Web query for CT session file list download&lt;br /&gt;
Pilot user interface for submitting the file list and starting processing pipeline&lt;br /&gt;
Notification about processing steps and failures&lt;br /&gt;
Upload results to XNat repository (at this stage results are uploaded into same folder where original scans are(*))&lt;br /&gt;
*** Immediate Plans&lt;br /&gt;
Complete Visual QC module&lt;br /&gt;
Design and implement meta-data transfer to XNat (including processing details and MRML files for loading images into the 3D Slicer)&lt;br /&gt;
&lt;br /&gt;
(*)Customization of results storage&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 6, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Tuned and debugged multiple subjects processing for: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat.&lt;br /&gt;
***Started working on quality control embedding into the above scenario. Plan to complete and video-record demo next week.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***Published general Product Integration scenario flow chart to collaborators' community. Discussion is open and in progress&lt;br /&gt;
&lt;br /&gt;
* October 30, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Piloted and tested the sequence: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat(1).&lt;br /&gt;
***Performance test of overall cycle: data transfer from remote serve is a bottleneck as expected&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data browsing features reviewed.&lt;br /&gt;
(1) Not automated yet&lt;br /&gt;
* October 23, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Defined COPD processing scenario with interoperability between Xnat, 3D Slicer Command Modules, Workflow, and Gridwizard Enterprise.&lt;br /&gt;
***Pilot version of Emphysema Measurements workflow pipeline deployed.&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data transfer features reviewed. Use account at XNat Central during learning curve.&lt;br /&gt;
***Feasibility test of 3D Slicer fiducials module for ROI highlights during QC and manual image processing activities. &lt;br /&gt;
* October 16, 2009&lt;br /&gt;
**Lung CT Scans Processing. Pilot project emerged. GenerateEmphysemaMeasurements module deployed as a webservice that submits jobs to computational cluster.&lt;br /&gt;
**EM Segmentation. Familiarized with GUI steps. Started working on automation steps outlining&lt;br /&gt;
**3D Slicer and XNat interaction. Got an overview from Wendy Plesniak.&lt;br /&gt;
* October 1 - 7, 2009&lt;br /&gt;
**Selected two first priority Projects: EM Segmentation of brain MRI images; Lung CT Scans Processing (COPD Study)&lt;br /&gt;
**Got initial outline of user requirements and design specs&lt;/div&gt;</summary>
		<author><name>Azaitsev</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=70354</id>
		<title>Projects:ARRA:SlicerWF</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=70354"/>
		<updated>2011-08-13T00:51:18Z</updated>

		<summary type="html">&lt;p&gt;Azaitsev: /* Progress */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Projects:ARRASuplements|Back to Slicer ARRA home page]]&lt;br /&gt;
= Aim =&lt;br /&gt;
Supplement 3D Slicer and Extensible Neuroimaging Archive Toolkit (XNAT) with workflow management system. Provide integration and interoperability between 3D Slicer, XNAT Services and 3-rd party image processing applications and high performance computing systems. Implement it as within currently developed Structural Planning and Implementation in Neurological Exploration (SPINE) System.&lt;br /&gt;
&lt;br /&gt;
= SPINE Project Documentation =&lt;br /&gt;
[http://cni.bwh.harvard.edu/projects/spine/index.html SPINE Docs]&lt;br /&gt;
&lt;br /&gt;
= Presentations =&lt;br /&gt;
* Segmentation Workflow. PECS University Social Cognition Study.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:SlicerWF_NAC_PECS_Workflow.pdf]]&lt;br /&gt;
* EAB10_ARRA Annual Progress Report Slides.&amp;lt;br&amp;gt;&lt;br /&gt;
[[media:EAB10_ARRA_WF_2011_Zaitsev.ppt | Service Oriented Solutions for 3D Slicer. EAB10_ARRA_WF_2011. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:EAB10_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:NAMIC_ARRA_WF_2011_Zaitsev.ppt  | NAMIC Annual Report 04/2010-03/2011. NAMIC_ARRA_WF_2011_Zaitsev. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:NAMIC_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:Slicer_WF_Slicer4CARMAWorkflow.ppt  | CARMA Workflow. Cardiac Ablation Followup. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:Slicer_WF_Slicer4CARMAWorkflow.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* CARMA Project Beta release Demo Location: http://cni29.bwh.harvard.edu/SlicerWFDemo/index.php&lt;br /&gt;
&lt;br /&gt;
* Segmentation Workflows: Screenshots, scans' and study description : [[File:SlicerWF_EMSegmentProjectsReview.zip]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
= All Hands Meeting Pages =&lt;br /&gt;
* MIT 2011 Summer:&lt;br /&gt;
 Workflows Project [http://www.na-mic.org/Wiki/index.php/Summer_project_week_2011_Workflows_SOA MIT_2011_WorkFlow]&lt;br /&gt;
 Segmentation Project (MS Lesions)[http://www.na-mic.org/Wiki/index.php/2011_Summer_Project_Week_Customizing_EMSegmenter_pipelines_for_brain_lesions MIT_2011_LesionsSegmentation]&lt;br /&gt;
* Salt Lake City 2011 Winter [http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA SLC_2011_WorkFlow]&lt;br /&gt;
* MIT 2010 Summer [http://wiki.na-mic.org/Wiki/index.php/Summer_project_week_2010_Workflows_SOA MIT_2010_WorkFlow]&lt;br /&gt;
&lt;br /&gt;
= Research Plan =&lt;br /&gt;
*Create a stand-alone SPINE desktop agent with fully functional data exchange and communication mechanisms towards 3D Slicer and XNAT.&lt;br /&gt;
*Develop Service Oriented Architecture (SOA) SPINE System that will include 3D Slicer image processing modules deployed as web services as well as a workflow management system to orchestrate interaction between 3D Slicer, XNAT, and 3-rd party tools.&lt;br /&gt;
*Implement two-way control and communications between 3D Slicer and SPINE modules.&lt;br /&gt;
*Adapt SPINE System for cluster and grid computing scenarios.&lt;br /&gt;
*Provide with workflow and 3D Slicer web service wrappers editing tools.&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:UseCaseScenarios| Use Case scenarios]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PETCTWorkflow| PETCTWorkflow]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:AgingStudySegmentation| AgingStudySegmentation]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:TwoTensorTractography| TwoTensorTractography]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:LongitudinalMultimodalityRegistrationSuite| LongitudinalMultimodalityRegistrationSuite]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:MigrationJavaClients2QT| MigrationJavaClients2QT]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PediatricMSSegmentation| PediatricMSSegmentation]]&lt;br /&gt;
*[[DBP3:Utah:RegSegPipeline| MRI-based study and treatment of atrial fibrillation]]&lt;br /&gt;
&lt;br /&gt;
= Application Server / Workflow Engine Downloads =&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:WFEngineDownloads| Download Links]]&lt;br /&gt;
&lt;br /&gt;
=Key Personnel=&lt;br /&gt;
* Charles Gutmann, MD., 4%,  9-17-2009 through 9-16-2011&lt;br /&gt;
* Alexander Zaitsev, Ph.D., 75%, 9-17-2009 through 9-16-2011 &lt;br /&gt;
&lt;br /&gt;
=Annual Progress Statements =&lt;br /&gt;
'''2010-11''' &amp;lt;br&amp;gt;&lt;br /&gt;
The  April 2011 – March 2011 period was devoted on developing portable workflow solutions that can be deployed on end-users' workstations or notebooks with minimal or no system administration activities. This is in contrast to the server-side deployment. The following scenarios had been deployed and used for actual projects that require the following types of workflows: PET/CT registration and computation of biomarker driven brain physiological activities, Brain MRI Images segmentation,  MRI and MRI Angiography images pre-processing for cardiac ablation outcome estimation. Some  workflows (like EM Segmentation) had been utilizing various scenarios, some research projects  (like evaluation of chemotherapy outcome) require two types of workflows to assess physiological and structural changes. Starting from the 4th Quarter of 2011, the migration project had been emerged in order to embed Workflow GUIs into newly developed Slicer4 Suite. The existing rich client Java GUI applications are being re-written as C++/QT Sliceletts units, new modules (such as cardiac ablation project support) are had been written from scratch. The latter are being deployed from the Slicer4 GUI and act at a liaison between Slicer4 and Application Server containing  workflow and Slicer modules deployed as services. The feedback from the end users indicates that Workflow approach for the complex processing improves productivity, aids to the processing standardization and contributes to the overall experience using 3D Slicer&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
=Quarterly Progress=&lt;br /&gt;
&lt;br /&gt;
* '''2d Qtr, 2011''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study: Second release deployed. &lt;br /&gt;
*** End-users completed the first Project and currently analyzing SUV values and clinical data&lt;br /&gt;
*** New features added: Human Brain Hemispheres segmentation, Scull-stripping for total SUV counts calculation, Flexibility of custom designed label look-up table usage (users can define ROI notation according to the Project needs)&lt;br /&gt;
&lt;br /&gt;
** Left Atrium Ablation Assessment (CARMA Project)&lt;br /&gt;
*** Completed workflow pipeline for automated pre-processing and manual intervention&lt;br /&gt;
*** Developed front-end GUI for the CARMA Project support in Slicer4.&lt;br /&gt;
*** Run the workflow with the end users during NAMIC Project Week&lt;br /&gt;
*** Evaluated feasibility of left atrium wall and post-ablation scar segmentation using Robust Statistical Segmentation (RSS). Identified necessary processing controls with RSS module designers&lt;br /&gt;
&lt;br /&gt;
** Multiple Sclerosis CLIMB Study&lt;br /&gt;
*** Reprocessing for lesion segmentation&lt;br /&gt;
*** Developed Web-based (Java EE 6) application for submitting cases to the workflows for EM Segmentation of MPRAGE and registration to PD/T2/FLAIR images (60% completion)&lt;br /&gt;
&lt;br /&gt;
** EM Segmentation: &lt;br /&gt;
*** Upgraded EM Segmentation services to Slicer 3.6.4&lt;br /&gt;
*** Added brain hemispheres segmentation module to the workflows (used for PET/CT Longitudinal study)&lt;br /&gt;
*** Work with EM Segmenter module developers on building pipelines for white matter lesion segmentation (work in progress)&lt;br /&gt;
&lt;br /&gt;
** Plans for the 3rd quarter&lt;br /&gt;
*** Migrate CARMA Project workflow to end-users&lt;br /&gt;
*** Packaging of Slicer4 Workflow modules and Slicer4 custom build distribution &lt;br /&gt;
*** Completion of Web-base segmentation and registration suite&lt;br /&gt;
*** Users and Developers Documentation&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* NAMIC Annual Progress Slides (April 2010 - March 2011):&lt;br /&gt;
&lt;br /&gt;
* '''1st Qtr, 2011''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study: Second release is under testing by end-users. &lt;br /&gt;
*** Added MRI registration to aid ROI drawing on PET scans&lt;br /&gt;
*** Improved SUV results reporting and added flexibility to update ROI lookup table&lt;br /&gt;
*** Automated EM Segmentation of MRI images for computing SUVs for white matter, CSF, and whole brain (80% completion)&lt;br /&gt;
*** Integration with SPECTRE scull stripping module (70% completion) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** EM Segmentation: Automated WF Pipelines are created &amp;lt;br&amp;gt;&lt;br /&gt;
*** Flexible atlas selection (Pediatric, etc) feature added&lt;br /&gt;
*** Workflows implemented for EM Segmenter 3.6.2 and 3.6.3 (1st Qtr 2011 release)&lt;br /&gt;
&lt;br /&gt;
** Cardiac ablation results follow-up: Workflow for registration and ROI selection of cardiac MRI and MR Angiography &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Wrokflow and Web Services for prospective DTI tractography modules (currently written as Matlab modules at PNL) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Web Services for SPECTRE Scull stripping module&lt;br /&gt;
*** Accuracy and performance tuning&lt;br /&gt;
*** 50% completion&lt;br /&gt;
&lt;br /&gt;
** Migration Front End GUI to Slicer4/QT:&lt;br /&gt;
*** EM Segmentation&lt;br /&gt;
*** Cardiac Ablation Study&lt;br /&gt;
&lt;br /&gt;
** DICOM Uploader and Desktop Browser for XNat Image repository (alpha version - tested for MGH MS Center studies, proposed to use with MI2B2 Clients and Services)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''4th Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study and EM Segmentation for Aging Study are deployed at end-user sites and actively used for research. &lt;br /&gt;
** Adopted EM Segmentation preprocessing pipeline for HIV Study: high resolution SPGR images, integration with FreeSurfer brainmask extraction outputs; integration of Slicer SPECTRE module for brainmask extraction is in progress.&lt;br /&gt;
** The following post-release upgrades had been implemented based on end-user feedback: Application Server basic controls are performed from Rich Client GUI as alternative to traditional IT administration activities. The controls are implemented on point-and-click bases and include web services and workflow application deployment and upgrades, application server start and stop as well as warning end user when the server is not accepting request.&lt;br /&gt;
** Added DICOM downloads and results uploads of PET/CT pipelines from and to XNat Repository&lt;br /&gt;
** Created Services and Workflow for Matlab Prototypes modules. Case Study: tractography for DTI images&lt;br /&gt;
** Extended XNAT integration services:&lt;br /&gt;
*** Browsing capabilities of XNat data repository from the Workflow Applications&lt;br /&gt;
*** Improved DICOM upload and download performance&lt;br /&gt;
*** Added Metadata organizing services for uploaded DICOM images: header data extraction, image snapshots creation. &lt;br /&gt;
** Started project for Rich Client GUI migration from Java desktop application to build into SLicer4 QT modules. This affects mostly front-end GUI and has the following approaches: distribution with the Slicer4, end-user will select desired workflow application from Slicer4 menu while QT-written modules provide with the same functionality as Java Rich Clients. Case Study for the Migration process: registration suite for longitudinal studies that include multi-modality images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* '''3d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Concentrated on building downloadable workflow applications that could run both in desktop (new) and server environment, and that require minimum IT administrative resources. The desktop deployment is in compliance with Slicer3 general deployment concept.&lt;br /&gt;
*** The following use case scenario had been chosen: PET/CT image processing for longitudinal studies, EM Segmentation for longitudinal Aging Study.&lt;br /&gt;
** Released workflow application for PET/CT image processing for longitudinal studies. Provided end users with training and documentation.&lt;br /&gt;
*** The PET/CT processing workflow was designed to be a general application used whenever both structural patterns and metabolic activities are within the research scope. &lt;br /&gt;
*** The desktop version is tuned to use minimal computer resources, so the automates processing instances do not interfere with human activities. Automated activities may include, for example, registration and PET scan's standard uptake values computing, and manual human activities may include image cropping, quality control, and labeling voxels of interest.&lt;br /&gt;
** Core services and EM Segmentation preprocessing workflow was build for retrospective Aging Study. Tuned the Slicer3 webservices for processing low grade images acquired in mid 90s. Entire workflow is implemented with Slicer3 only modules and can be deployed locally and on the servers. Usage of Service Oriented Architecture (SOA) as a core technological approach allowed reusing most of the web services that had been build for PET/CT project. &lt;br /&gt;
** Continued embedding Slicer3 application and modules into previously released processing pipelines: replaced MIPAV with Slicer3 GUI for lesion assessment step in the multi-center Pediatric MS Cohort image processing &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''2d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Completed Social Cognition Workflow Implementation. This includes EM Segmetnation pre- and post-processing pipelines, data tracking, and integration with 3d party image processing utilities, as well as processing results acquired manually with Slicer GUI.  &lt;br /&gt;
** Multi-modality image registration and ROI selection/alignment workflow for longitudinal studies. &lt;br /&gt;
*** Use case: PET/CT image processing for longitudinal studies. &lt;br /&gt;
*** Build portable library of Slicer modules as web services and workflow that are deployed and run on a end-users' worksatations without utilization of SPL and other servers. The web services include novel Slicer3 modules, such as BRAINSFit and BRAINSResamle &lt;br /&gt;
*** Started working with Slicer3 developers on Slicer 3.8 GUI wizard to communicate with workflow instances.&lt;br /&gt;
** Participated at NA-MIC Summer 2010 Project Week: [[Summer_project_week_2010_Workflows_SOA]]&lt;br /&gt;
&lt;br /&gt;
=Progress=&lt;br /&gt;
* August 12, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
* Migrating build to updated Slicer4 environment  (PythonQT and new added module dependencies issues)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation&lt;br /&gt;
* Tested and reviewed EM Segmentation web app on end-users' data&lt;br /&gt;
* Updated workflow, so EM Segmentation is performed on T1 after registration to T2 or FLAIR. This gives more accurate results comparing to segmentation of high resolution image followed by resampling (have to use nearest neighbor interpolation to retain actual label values) of label map &lt;br /&gt;
&lt;br /&gt;
* August 5, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT&lt;br /&gt;
* Follow-up with end users with new Study setup&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
CARMA Project&lt;br /&gt;
* Documentation (Work in progress)&lt;br /&gt;
* Plans for next week: custom packaging (Mac Snow Leopard 64 bit), building extension, documentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation&lt;br /&gt;
* Stress-test of online segmentation requests suite for  [http://www.slicer.org/slicerWiki/index.php/EMSegmenter-Tasks#Additional_Use_Cases CLIMB Study](for BWH MS Center)&lt;br /&gt;
* Reason for building online suite: the Group is Using mostly MAC OS Tiger machines for legacy reasnos, the most recent Slicer3 builds as well as QT don't work on those machines (QT4.x runtime could not be installed).&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* July 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA Project&lt;br /&gt;
* Documentation (Work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation&lt;br /&gt;
* Work on alpha-release of online submission of segmentation requests (for BWH MS Center)&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* July 22, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
Vacation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* July 8, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
3D Slicer in General and CARMA Project&lt;br /&gt;
* Presentation and life demo at Cardiology Research Center (Moscow, Russia) [[File:RussianCardiologyCenterCARMA2011.ppt]]&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* July 1, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA V1.0&lt;br /&gt;
* Migration to new QT building environment (Mac 10 Snow Leopard). &lt;br /&gt;
* Building custom package. Issues: new features (not only WF related) are not shown on the menu of the resulting application&lt;br /&gt;
* Comparing preprocessing workflow results with published in literature data (our module produces better alignment)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*June 24, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
Project Week:&lt;br /&gt;
* Testing RSS module for left atrial wall scar segmentation&lt;br /&gt;
* Testing EM Segmenter for lesion detection on PD (requested by end-users) and FLAIR images&lt;br /&gt;
&lt;br /&gt;
EM Segmentation &lt;br /&gt;
* Web-based segmentation and registration module for MS Center. Goal: facilitate 3D SLicer modules for the cases that could not be processed with in-house build DTS+ algorithm&lt;br /&gt;
* Pipeline: Segment MPGR or T1 (user's choice), Register MPGR to PD/T2, Resample Segmentation Map to PD/T2. Completion: 60-70%.&lt;br /&gt;
* The rest will be done manually or via lesion segmentation with EM Segmenter.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* June 17, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
Preparation for Project Week&lt;br /&gt;
&lt;br /&gt;
* June 10, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
CARMA V.1.0&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code completed and tested&lt;br /&gt;
* Packaging as extension is pending (Subject for Summer 2011 Project week)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Debugging consolidation results issue(SUVs for manual and automated segmentation) &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* June 3, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Deployed on end-user's machine&lt;br /&gt;
* TODO next week: fix SUV results consolidation issue (when MRI segmented ROI got SUV computed for some subjects, only those subjects' SUVs are being added into consolidated report. &amp;quot;Raw&amp;quot; SUV values per subject are generated as expected)  &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 27, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Ready for deployment. New Features: hemispheres EM Segmentation, automated ICC/brainmask extraction using EM Segmenter, fixed controls for MRI conversion and registration&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 20, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General / PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Hemispheres EM Segmentation - adjusted for required label lookup table&lt;br /&gt;
* Use cases added for EM Segmenter General Project: http://www.slicer.org/slicerWiki/index.php/EMSegmenter-Tasks#EMSegmenter_use_cases&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SPECTRE Scull Stripping&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* The new version to be tested on coming week (After PETCT MRI processing migrated to Hemispheres scenario )&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* May 13, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General / PETCT V1.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Hemispheres EM Segmentation - technically works with labal values hardcoded in Slicer EM Segmenter - need to add manual label value edition step&lt;br /&gt;
* PETCT WF Cut for Java GUI (Pending Hemispheres label update completion). Next release will be in QT4.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* May 6, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (QA of EM Segmenter module, work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* April 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Open Discussion for Packaging WF QT Modules as Slicer4 extensions (waiting for SOPs)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review supported projects http://wiki.na-mic.org/Wiki/index.php/File:SlicerWF_EMSegmentProjectsReview.zip &lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (required by Study)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Slicer Modules General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Standardizing Crop Volumes Output (with A. Fedorov's module). Review for required updates of existing product (PET/CT, CARMA)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Open Discussion for Packaging WF QT Modules as Slicer4 extensions (waiting for SOPs)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review supported projects http://wiki.na-mic.org/Wiki/index.php/File:SlicerWF_EMSegmentProjectsReview.zip &lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (required by Study)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Slicer Modules General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Standardizing Crop Volumes Output (with A. Fedorov's module)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 22, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Beta release ready. Demo Location: http://cni29.bwh.harvard.edu/SlicerWFDemo/index.php&lt;br /&gt;
* TODO: Tutorial. Original inputs copy/renaming&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 15, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Adding App server auto-config features&lt;br /&gt;
* Finalizing the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 08, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Second release beta build tested on cosutmer side &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review registration quality (with Dr. Meier). Angiography images' Resampling tuned. &lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 01, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the second release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
XNat Integration&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* (Java) GUI for Project Browsing and DICOM Series Upload. Post-upload DICOM processing tested and debugged&amp;lt;br&amp;gt;&lt;br /&gt;
* Ready for integration with mi2b2 client.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Migrated to Latest Slicer 3.6.3 stable release: only the Input scene had to be updated, the API remained the same&lt;br /&gt;
* Tested EM Segmenter with CMTK4Slicer extension - processing takes to much time on Linux_64bit machine, rolled back to BRAINSFit registration. When used on Mac OS X build, the Slicer could not start (bug report 1126).&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SPECTRE Scull Stripping:&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Testes for various use cases: the module is extremely sensitive to T1 MRI quality (does not work for most MRIs from PET/CT project&lt;br /&gt;
* TODO next week: check for FLAIR images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Slicer4 QT GUI and Cropping activity in progress.&amp;lt;br&amp;gt;&lt;br /&gt;
* Tried direct MRA to MRA registration option: resampling with LMRI registration transforms works better.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Extra VOI labels revised&lt;br /&gt;
* Debugging of SUV results' renormalization step&lt;br /&gt;
* TODO: ICC extraction / whole brain total uptake computing; EM Segmentation for R_WM, L_WM SUV computing and BPH estimation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SCULL STRIPPING/SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Installed and tested CLI option on Linux_64bit platform&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Workflow interruption before BSPline registraton: BPEL Module completed. Slicer4 QT GUI and Cropping activity in prorgess.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Implemented and Tested with end-users proposed changes: denormalization of SUV results, adding more VOI labels, added FLAIR MRI in addition to T1s for VOI drawing&lt;br /&gt;
* Tested manual ICC extraction using PET scans: works satisfactory with island removal and cropping followed by threshold level labeling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4&lt;br /&gt;
* Change proposed: interrupt workflow after affine registration and have user crop the VOI. This is to prevent excessive deformations for BSpline registration and resampling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4. User has option to choose the atlas that fits better for the given subject (NOTE: hardcoding must be rewritten for atlas linking)&lt;br /&gt;
* PETCT test - the problem is that T1s are low resolution and with contrast. Proposed using T1s without contrast&lt;br /&gt;
* PETCT change request: users wants to compute SUV for entire ICC. Had demo how to segment brainmask/ICC using PET scan. The derived brainmask label can be used for SUV computation.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - cmpleted&lt;br /&gt;
* Sample cases run - excessive deformation after BSpline registration hase&lt;br /&gt;
* Next week plan - pull tuning controls to front-end of pipeline API, start working of QT module for CARMA registration&lt;br /&gt;
* May consider other than BRAINSFit registration modules&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Design plan for change request: more VOI labels, add FLAIR in addition to T1 for VOI drawing, T1s segmentation&lt;br /&gt;
* Tested segmentation for sample cases - artifacts from poor quality MRIs lead to exclusion of parts of ICC from segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Completed troubleshooting of EMSegmenter module calling from Java (need TCL libs to be pulled from Slicer environment)&lt;br /&gt;
* Tested EMSegmenter autoruns for HIV and Pediatric MS patiens. Work as expected, subject to improvement of PED MS case segmentation by building better skull/neck/air atalses&lt;br /&gt;
* Suggested usage of two subsets of atalases: with and without neck. The Subject MRIs have to be cropped accordingly or best fit atlas has to be selected&lt;br /&gt;
* Made no-neck cropped atlas collection for default EMSegmenter scenario&lt;br /&gt;
* Tested with PET/CT study MRI cases - see above &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - in progress&lt;br /&gt;
* Next week goal - have back end processing ready&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Longitudinal Study&lt;br /&gt;
* Added MRI registration to the pipeline&lt;br /&gt;
* Troubleshooting of complex XML schema issues on Linux machines (some modules working on MAC do not work on Linux). As a workaround - did not include MRI convert and register part into base BPEL module. Used separate services (transparent for end-user)&lt;br /&gt;
* TODO next week for change request completion: explicit pixel type casting for MRI in BRAINSFit, VOI MRML scene update (currently MRI added on top of schema)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* February 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipeline for Pediatric MRI. Same scenario as for HIV Project, icbm pediatric atlases (Completed, verified)&lt;br /&gt;
* Collected NIH healthy brain development atlases: various age ranges from 4.5 to 18 yo. Converted to Slicer readable format &lt;br /&gt;
* Work on web services for the new automated EM Segmenter module (release Nov 10 - current). Verified task completion both for adult and pediatric images. Discussed tuning parameters for work load balance on workstations.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Started working on MRI registration to the reference CT scans. &lt;br /&gt;
* Design specs for optional White Matter segmentation for SUV computing.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* February 4, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipelines for Pediatric MRI (in progress)&lt;br /&gt;
* Adapting Pediatric T1 atlases for &amp;quot;Human Brain&amp;quot; build-in EM Segmentation wizard (in progress)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 28, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Verifying EM Segmenter module for latest builds and HIV/PED MS Studies (report pending)&lt;br /&gt;
* Work with SPECTRE module developers with pediatric MRI brainmask extraction&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* January 21, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Compiling plan for WF FrontEnd GUI migration to Slicer4/QT Widgets&lt;br /&gt;
* Preparing for annual progress report&lt;br /&gt;
&lt;br /&gt;
* January 14, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI: Integrated into the Slicer4 as Slicelet (or thin Client)&lt;br /&gt;
* Participation at AHM-2011, discussing integration of SPECTRE module and updated approach to EM-Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA&lt;br /&gt;
&lt;br /&gt;
* January 7, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* HIV project workflow delivered. Major additions relate to user convenience: &lt;br /&gt;
- Project-specific parameter settings, importing T1s and brainmasks from FreeSurfer outputs with conversion to NIFTI, resampling brainmask to original scans and automatied subject addition.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Follow up with end user: need to add MRI scans, if available, addition and registration to CT in order to ease VOI drawings.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
 &lt;br /&gt;
* December 31, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Follow-up with user Experience for AGING Study Segmentation (Positive feedback)&lt;br /&gt;
* Target date for HIV project delivery - next week&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Self-training for QT widget development&amp;lt;br&amp;gt;&lt;br /&gt;
* Outlined Workflow Rich Clients migration strategy from Java to QT/Slicer4:&amp;lt;br&amp;gt;&lt;br /&gt;
** Use Java Stubs (similar to SPECTRE integration) or file binding for envocation of workflow pipelines. (See SOAP remark below)&lt;br /&gt;
** Direct Web Servisec calls must be wrapped into REST protocol. The reason: NON-commerchial QT kit does not include SOAP protocol for web servises.&lt;br /&gt;
** The GUI will be implemented as page widget or QT dialog GUI forms called from within Slicer4.&lt;br /&gt;
** Communications between Slicer4 and WF GUI will be set via child-parent and signal-slot relations&lt;br /&gt;
* Worked on a Prototype for Basic EM Segmentation QT widget (70% complete). Will work on integrtion with SLicer4 during the AHM-2010&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
XNAT Integration&lt;br /&gt;
* Debugged XNAT RESTFul API usage for uplaoding DICOM series followed by header data extraction and image snapshots creation&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Added compensation for failed atlas registration (subject for old poor quality pseudo-T1 images): blank probability maps are created in case of failure.&lt;br /&gt;
* Data preparation module for FreeSurfer data import near completion. Expected time for deployment at end-users workstations - first week of January&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Discussed strategy for EM Segmentation pipeline solutions collection (K. Pohl, R. Kikinis)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* RE-using the same core workflow as for 1-channel EM Segmentation of AGING STUDY cases&lt;br /&gt;
* Added data input preparation module: ICC label mask preparation and skull-stripping based on FreeSurfer brainmask output volume.&lt;br /&gt;
* Two-channel EM segmentation pipeline (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE / GENERAL Development &amp;lt;br&amp;gt;&lt;br /&gt;
* Worked on plans for migrating fro rich workflow Java clients to embedded workflow windows inside the Slicer.&amp;lt;br&amp;gt;&lt;br /&gt;
The embedded workflow management clients are to be implemented with QT/PyQT toolkits&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
INTEGRATION WITH XNAT:&amp;lt;br&amp;gt;&lt;br /&gt;
* Automated DICOM series upload with triggering DICOM headers parsing at XNat site (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress. &lt;br /&gt;
- Results upload to XNat (Completed) &amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat based on user's input (Project + Subject + PET or CT session / scan) (Completed)&amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat - perfomance boosting solution for downloads found , web services services are created, relinking for the client side in progress &amp;lt;br&amp;gt;&lt;br /&gt;
- Xnat querying for subjects and automated subject addition into the workflow (In Progress) &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-segmentation module added for auto correction of segmentation results. Particularly - relabeling CSF voxels segmented as Air inside the intracranial cavity. This was requested by end-users after processing images with zero-signals in CSF voxels &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting automated dual-echo DICOM images conversion and split into two NRRD volumes&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT / EM Segmentation pipeline:&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting memory allocation issues for scull-stripping module SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
COPD Project:&amp;lt;br&amp;gt;&lt;br /&gt;
* Benchmark test for accelerated DICOM downloads from XNat (remoote XNat Central server): we can handle at least 6 cases (4 CT scans in each) per hour, which is compatible with current workload quotes on SPL cluster processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* December 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Deployed Version 1. &amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Test project chosen as a closest match to registration scenario: Pediatric MS Cases from MGH - requires periodic image preview for different &lt;br /&gt;
modalities taken from vaious time points. Label maps for VOIs resampling is also required.&lt;br /&gt;
&lt;br /&gt;
* November 26, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user. Version 1 is complete&amp;lt;br&amp;gt;&lt;br /&gt;
* Started working on integration with XNat&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on input data organizing modules&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 19, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user (70% done)&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Universal Registration Workflow for Longitudinal Studies - design specs in progress&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 12, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Minor tuning to EM Segmentation template as of users' feedback&lt;br /&gt;
* Users started using the workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed input data conversion from Genesis to Slicer native or NIFTI format. Our help may be needed in input data organizing.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Tuned application according to co-laborators (PNL) needs&amp;lt;br&amp;gt;&lt;br /&gt;
* The webservices and BPEL workflow application are tested ready to accept computation requests from PNL case tracking system &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Discussed Universal Registration Workflow for Longitudinal Studies&lt;br /&gt;
* Started the thread about possible cooperation with Children hospital's image processing pipelines and integration with Xnat &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 5, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Webservices and workflow pilot project created and deployed on Psychiatry Neuroimaging Laboratory subnet &amp;lt;br&amp;gt;&lt;br /&gt;
* The V.1.0 deployment is scheduled for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 29, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Most of functionality is completed. Some volume statistics post processing is pending&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL EM SEGMENTATION Pipeline: &amp;lt;br&amp;gt;&lt;br /&gt;
* The SPECTRE scull stripping module. Started integration into EMS workflow. Made some test runs from Slicer GUI&amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Identified as a candidate for Workflow Application&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 22, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* All back-end functionality are implemented&amp;lt;br&amp;gt;&lt;br /&gt;
* EM Segmentation scene usability is confirmed by end-user&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for next week: add Label Statistics computation for CSF/Brain/ICC &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 15, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* The latest (October) builds of Slicer 3.6.2 produced acceptable results. This was verified by the target users. The EM Segmentation will be performed on Slicer 3.6.2 or later&amp;lt;br&amp;gt;&lt;br /&gt;
* The new Web services had been created and added to the pipeline as optional processing steps: Biasfield correction (implement novel N2ITKBiasFieldCorrection module) and Volume's scalar datatype casting (as workaround for Biasfield correction module not preserving image scalar datatype - the bug is filed) &amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed the Front-End GUI design with target users. The design pattern is taken from the PETCT project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 8, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-deployment support. Tuned CT registration as of user's feedback.&lt;br /&gt;
* Adapting to the Single Slicer build: Slicer 3.6.2. Found label duplicates in the label lookup table - will ask user if it's tolerable. Waiting for the Slicer 3.6.2 build that contains all required modules. Rolling back label tag appending code for SUVs - the latest Slicer build appends the tags.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Resumed development. The priorities are set for usage of Slicer 3.6.2 - subject for EM Segmentation scene tuning. Continued coding for Scene creation for Slicer 2.8 - as a backup option for ongoing research project.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 1, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized V1.0 release based on end-user feedback: updates relate mostly to error proofing and SUV values representation&lt;br /&gt;
* Post-deployment support. Users pre-processed first set of patients &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* September 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* System deployed and tested at End Users' site.&amp;lt;br&amp;gt;Users are trained to perform all tasks required by the workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
* Got positive feedback with suggestions on Slicer Scenes' layouts improvement and PET scans' SUV (standard uptake values) results display&lt;br /&gt;
* Two distribution packages are assembled: Lunix and MAC OS versions. The difference in two packages is in specific Slicer3.6/3.7 builds - subject to Slicer Linux builds debugging.&amp;lt;br&amp;gt; As a workaround for Linux deployment - multiple Slicer builds are used to perform various tasks (registration, opening editing scenes in Slicer, SUV computing)&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for coming week - finalize V1.0 release based on end-user feedback&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Embedded SUV computations into the workflow (as system calls - will be translated into web service later)&amp;lt;br&amp;gt;&lt;br /&gt;
* Pre-release demo for end users.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Create and debug EM Segmenter scenes template for Slicer 3.6 and 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* September 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation - workflow pipeline and deployment verified&amp;lt;br&amp;gt;&lt;br /&gt;
* Tested EM Segmentation scenes within Slicer 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
* Started migration of EM Segmentation to Slicer 3.6. Discovered issues had been reported to EM Segmenter module designers &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* August 29 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation completed. Preprocessing Pipleine completed 80% (subject for input registration parameters tuning) &amp;lt;br&amp;gt;&lt;br /&gt;
* Most webservices (for registration and resampling steps) had been taken and re-used from PET/CT ROI/Longitudinal Study - showing the advantage of service-oriented software design and deployment.&lt;br /&gt;
* Continued on distribution and deployment of the service/workflow applications: on PET/CT and AGING STUDY projects.&lt;br /&gt;
&lt;br /&gt;
PEDIATRIC Multiple Sclerosis Cohort. Support of multi-center distributed processing project&amp;lt;br&amp;gt;&lt;br /&gt;
* Introduced Slicer 3.6 for the MS Lesion Assessment step performed at Mayo Clinic. Images are being transferred from image repository at BWH and automatically opened and arranged within Slicer GUI for reading.  This was replacement of Client GUI using MIPAV that stopped working on new computers at Mayo Clinic.&lt;br /&gt;
The images are being loaded via generated MRML Scenes same way as in PET/CT and AGING STUDY projects &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* August 22 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Preprocessing pipeline merge with SUV computations &amp;lt;br&amp;gt;&lt;br /&gt;
- QA for SUVs computation was performed by Wendy Plesniak for images with known uptake values. &amp;lt;br&amp;gt;&lt;br /&gt;
- Discovered that image cropping step (not related to automated registration pipeline and SUVs computing) smoothes the images by doing interpolation when used with default settings. Got suggestions from Steve Piper using Nearest-Neighbor interpolation (&amp;quot;no interpolation&amp;quot;) for a time being&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
- This is the new project candidate. Requested for the images with failed manual segmentation and/or segmentation with FreeSurfer. The EM Segmentation run showed most acceptable results on one of the problem images back in February &amp;lt;br&amp;gt;&lt;br /&gt;
- The workflow will be developed and deployed similar to PET/CT ROI Longitudinal study approach - all preprocessing steps will be done with Slicer modules, all runs will be performed on local end-user machines.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
 &lt;br /&gt;
&lt;br /&gt;
* August 15 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- First 5 cases with 3-4 time points preprocessed for SUVs computation&lt;br /&gt;
&lt;br /&gt;
* August 8 2010&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Testing of installation and operation at users' site (Performed by Wendy Plesniak)&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* July 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Delivered beta version of registration pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
- Prepared installation and user manuals &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* June 11, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Registration modules completed &amp;lt;br&amp;gt;&lt;br /&gt;
- Irregular cases registration problem solved (when whole body and brain only scans are mixed for a timepoint)&amp;lt;br&amp;gt;&lt;br /&gt;
- Live demo of case setup and registration workflow for end users. Real case with 4 timepoints used&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Coming week plans&amp;lt;br&amp;gt;&lt;br /&gt;
- Adjust workflow based on end users' feedback&amp;lt;br&amp;gt;&lt;br /&gt;
- Integration with SUVs computing for PET scans&amp;lt;br&amp;gt;&lt;br /&gt;
- GUI for workflows dispatching and data organizing&amp;lt;br&amp;gt;&lt;br /&gt;
- (TBD) Integration with 4D time series analysis Slicer module&amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
* May 28, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- Migration to the latest Slicer 3.6 release candidate &amp;lt;br&amp;gt;&lt;br /&gt;
- Added webservice for new registration module: BRAINSFit &amp;lt;br&amp;gt;&lt;br /&gt;
- Test runs for new patients with 4 timepoints' scans &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Plans for next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI &amp;lt;br&amp;gt;&lt;br /&gt;
- processing workflow demo for end user &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 21, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Pilot version of portable web services and automated workflow tested: &amp;lt;br&amp;gt;&lt;br /&gt;
Linux: workflow and visual review passed&amp;lt;br&amp;gt;&lt;br /&gt;
Stress test for 25 timepoints passed &amp;lt;br&amp;gt;&lt;br /&gt;
MAC OS: workflow passed, visual review failing when PET/CT images are loaded into GUI simultaneously (bug report submitted)&amp;lt;br&amp;gt;&lt;br /&gt;
Windows: need to adapt command line modules and workflow management system to sygwin environment&amp;lt;br&amp;gt;&lt;br /&gt;
Plans for next week: integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI&lt;br /&gt;
&lt;br /&gt;
* May 7, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Selected registration and resampling modules with more precise and stable outputs. &amp;lt;br&amp;gt;&lt;br /&gt;
Started building portable web services and automated workflow &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 30, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- manual walk through the processing steps: ROI cropping, registration/resampling, PET pharmaceutical DICOM data retention. &amp;lt;br&amp;gt;&lt;br /&gt;
- testing workflow and web services packages distribution to end-users' machines&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* April 23, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : testing various registration and re-sampling algorithms (work in progress)&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation: as of collaborators' request, run existing EM Segmentation workflow for older low resolution pseudo-T1 images. The EM Segmentation works for those images with manual sampling. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 16, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
  Social Cognition Study: started Cortical Thickness Measurement module build (bases on NA-MIC ARCTIC pipeline) &amp;lt;br&amp;gt;&lt;br /&gt;
  PET/CT ROI/Longitudinal Study Registration : Design specs, PET-to-CT images registration tests on training data. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 9, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. GUI update based on end-user experience.&amp;lt;br&amp;gt;&lt;br /&gt;
User request: automated label maps' volumes calculation (Currently possible from Slicer3 GUI)&amp;lt;br&amp;gt; &lt;br /&gt;
PET/CT ROI Project. Initial design specs discussion with end-users and co-developers&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure&lt;br /&gt;
Verification of segmentation workflow GUI: from registering new case to reviewing results&amp;lt;br&amp;gt;&lt;br /&gt;
Cross study test of segmentation workflow: MGH/MS Center data - success,  HIV Project data - some EM Segmentation scene tuning is needed &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*&lt;br /&gt;
* April 2, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. Segmentation workflow completed&amp;lt;br&amp;gt;&lt;br /&gt;
* Coming Week plans:&amp;lt;br&amp;gt;&lt;br /&gt;
- Document Segmentation Workflow. Follow up with end users &amp;lt;br&amp;gt;&lt;br /&gt;
- Start with Cortical Thickness and ROI-in-longitudinal studies workflows&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* March 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All essential processing and workflow interaction clients are ready.&amp;lt;br&amp;gt;&lt;br /&gt;
- Completed segmentation for 10 out of 50 patients. The remaining cases will be finalized upon manual lesion segmentation and QC verification of WM/GM/CSF and Deep GM segmentation's. &amp;lt;br&amp;gt;&lt;br /&gt;
- TODO next week: refine QC GUI and data tracking / progress monitoring schema. &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&amp;lt;br&amp;gt;&lt;br /&gt;
- New Slicer3 web services added: re-slicing with reference image volume, casting image scalar type &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
* March 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Segmentation maps Merging Services for GM/WM/CSF (Slicer EM Segemnter), Lesion (Slicer, Manual), and Deep GM (FreeSurfer)  &amp;lt;br&amp;gt;&lt;br /&gt;
- Deep GM segmentation pipeline adopted as optional service for Social Cognition Study (22 out of 50 cases processed) &amp;lt;br&amp;gt;&lt;br /&gt;
- (In progress) GUI client for Launching Segmentation results merging with optional Deep GM segmentation with FreeSurfer &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- Complete GUI Client for Segmentation result merging &amp;lt;br&amp;gt;&lt;br /&gt;
- Progress Monitoring services for entire Study processing: EM Segmenter Preprocessing, EM Segmentation, Lesion Segmentation (including human activities assignments), Deep GM segmentation, and results consolidation. &amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* March 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All 50 cases went through &amp;quot;basic&amp;quot; One-channel EM segmentation (GM/WM/CSF) &amp;lt;br&amp;gt;&lt;br /&gt;
- Basic pipeline start-up command line client created: user has two options - request brainmask extraction or provide with previously extracted brainmask for a given subject &amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison of GM/WN/CSF performed for Slicer EM Segmenter and FreeSurfer recon-all (used with default settings). &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmenter provides more accurate output &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmentation pipeline runs faster (40 minutes vs 12 hrs when no brainmask extraction requested) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO:&amp;lt;br&amp;gt;&lt;br /&gt;
- merging modules for automatic 1-channel EM segmentation and manual lesion segmentation &amp;lt;br&amp;gt;&lt;br /&gt;
- Emerge Cortical Thickness pipeline project: use NAC ARCTIC processing steps and modules &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Selected stable EM Segmentation scenario: White Matter, Gray Matter, and Cerebrospinal Fluid &amp;lt;br&amp;gt;&lt;br /&gt;
- First 16 cases are segmented for selected scenario. Nine more cases are preprocessed for EM Segmentation.&amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison to segmentation with FreeSurfer showed better accuracy for Slicer2 EMSegmenter &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure &amp;lt;br&amp;gt;&lt;br /&gt;
- Three prerpcocessed cases failed during volume ICC masking with in-house build utility. Evaluated switching to Slicer3 Mask and island removing modules.&amp;lt;br&amp;gt;&lt;br /&gt;
- Initial design specs discussion for cortical thickness measurement pipeline. ARCTIC pipeline selected. ARCTIC preprocessing steps signifficantly overlap with EM Segmentation preprocessing workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
  &lt;br /&gt;
* February 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: &amp;lt;br&amp;gt;&lt;br /&gt;
A) parameters tuning for EM Segmenter itself (work with EM Segmenter developer), template scenes creation &amp;lt;br&amp;gt;&lt;br /&gt;
B) update preprocessing pipeline - deep gray matter atlases included &amp;lt;br&amp;gt;&lt;br /&gt;
C) test and debug preprocesing pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
D) identified missing modules: atlas autocalibration for EM Segmentation scene, Island removal for ICC mask&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- Review currently deployed modules. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: reviewed firts seven subjects' outputs, added volume orientation module into pipeline (prevents ICBM atlas linear registration failures)&amp;lt;br&amp;gt;&lt;br /&gt;
- Fused ICC(brainmask) extraction module with EM Segmenter preprocessing. Three scenarious implemented: start with pre-extracted ICC mask (longitudinal studies case), run with ICC ectration, run with ICC extraction AND ICC correction before ICBM atlas preporcessing. &amp;lt;br&amp;gt;&lt;br /&gt;
- Completion of Human activities GUI (QC, ICC Correction) planned for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: Volume Orientation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: automated preprocessing pipeline for Slicer2 EM Segmenter test version deployed. Seven cases pre-processed.&lt;br /&gt;
- PET Quantitative measurements: Preliminary design specs discussion.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: BSplineRegistration (for non-linear registration), ResampleVolume2 (for atlases resampling based on image atlase templates registration). Local and Network runs are implemented, Cluster/GridWizard implementation pending.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Slicer EM Segmenter module: preprocessing design for Slicer2 EM Segmenter&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Adapting for Slicer2 EM Segmenter (mostly from pipelines and services for previous projects)&lt;br /&gt;
  -- Integration with FreeSurfer modules for bisafield correction, brainmask extraction, and linear registration of ICBM atlases&lt;br /&gt;
  -- Preprocessing updates for non-linear registration of ICBM atlases with Slicer2 (image re-orientation service designed)&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 29, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- EM Segmentaton pipeline: preprocessing results are being transferred to XNat (anonymized data, Central XNat) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Slicer EM Segmenter module: discussed agenda and scheduled a work meeting for Social Cognition Study image segmentation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Testing stage, 95% completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- SPL XNat server: verified data exchange via RESTfull web services.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 22, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Follow up with White Matter Lesion Segmenter and Scull Stripping Modules developers: Work in Progress&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Work in Progress, 60%+ completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Discussed SPINE image repository migration to XNat&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 15, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. &lt;br /&gt;
- Social Cognition Study: &lt;br /&gt;
Work-in-progress on intermediate (reconstruction) and results (resources) data storage at XNat.&lt;br /&gt;
&amp;lt;br&amp;gt;Reviewing and preparation more cases for EM Segmentor (Slicer 3.5) tuning.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* NA-MIC Project Week&lt;br /&gt;
Selecting candidate Slicer modules for other than Lesion EM Segmentation topics of Social Cognition study: Withe Matter Lesion Segmenter (UNC), Scull Stripping utility from UIOWA.&lt;br /&gt;
Reviewing issues of currently used Scull Stripping Slicer Extension and Slicer 3.5 EM Segmenter.&lt;br /&gt;
&amp;lt;br&amp;gt;XNat Data organizing training&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 1, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Preparation of Demo for NA-MIC work week: &lt;br /&gt;
- COPD Study. Added Remote pipepline start interface (represents real world scenario where Xnat repository, Processing modules and User are at different sites)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
- EM Segmentation. Added human activities steps to the workflow: ICC (brainmask) correction and EM Segmantation scena load per se.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 25, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Pilot workflow pipeline for EM Segmentation (all steps except user-activity step: ICC correction assignment and tracking)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 18, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Build and tested web services for EM Segmentation image preprocessing: DICOM-to-NRRD conversion, registration, skull stripping, image masking.&lt;br /&gt;
Started building workflow pipeline (subject to finish first version next week)&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Started Collecting Library of Slicer Build number vs. functional modules and extensions.&lt;br /&gt;
Plan for NAMIC project week: scheduled meetings for XNat data customization, Skull-stripping modules tuning, identified Social Cognition study cases that fail EM Segmentation processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 11, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Updating and verification of EM Segmentation Scenario&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Projects:ARRA:SlicerWF:UseCaseScenarios#Usecase_MS_lesion_Assessment&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Familiarizing with Slicer3.4/5 Modules required for implementation of EM Segmentation Scenario. Participation in debugging and/or usage tuning of Dicom Conversion, Registration, Skull Stripping, Masking, and Image Casting modules. &lt;br /&gt;
&lt;br /&gt;
* December 4, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Slicer3.4's EM Segmentation and Visual QC as part of image processing pipeline for Social Cognition Study for MS Patients.&lt;br /&gt;
Project emerged. EM Segmentation template creation debugged.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
Emphysema Measurements (COPD Study) - workflow stability and scalability test.&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 27, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Emphysema Measurements (COPD Study).&lt;br /&gt;
Added compensation for long running calculations and time-outs to the main computing pipeline.&lt;br /&gt;
Visual QC (work in progress)&lt;br /&gt;
** Infrastructure&lt;br /&gt;
XNat data structure customization, metadata storage, results consolidation: new feature request list creation (work in progress)&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 13, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
*** Pilot system for whole processing cycle for Emphysema Measurements (COPD Study) including the following:&lt;br /&gt;
Web query for CT session file list download&lt;br /&gt;
Pilot user interface for submitting the file list and starting processing pipeline&lt;br /&gt;
Notification about processing steps and failures&lt;br /&gt;
Upload results to XNat repository (at this stage results are uploaded into same folder where original scans are(*))&lt;br /&gt;
*** Immediate Plans&lt;br /&gt;
Complete Visual QC module&lt;br /&gt;
Design and implement meta-data transfer to XNat (including processing details and MRML files for loading images into the 3D Slicer)&lt;br /&gt;
&lt;br /&gt;
(*)Customization of results storage&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 6, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Tuned and debugged multiple subjects processing for: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat.&lt;br /&gt;
***Started working on quality control embedding into the above scenario. Plan to complete and video-record demo next week.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***Published general Product Integration scenario flow chart to collaborators' community. Discussion is open and in progress&lt;br /&gt;
&lt;br /&gt;
* October 30, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Piloted and tested the sequence: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat(1).&lt;br /&gt;
***Performance test of overall cycle: data transfer from remote serve is a bottleneck as expected&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data browsing features reviewed.&lt;br /&gt;
(1) Not automated yet&lt;br /&gt;
* October 23, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Defined COPD processing scenario with interoperability between Xnat, 3D Slicer Command Modules, Workflow, and Gridwizard Enterprise.&lt;br /&gt;
***Pilot version of Emphysema Measurements workflow pipeline deployed.&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data transfer features reviewed. Use account at XNat Central during learning curve.&lt;br /&gt;
***Feasibility test of 3D Slicer fiducials module for ROI highlights during QC and manual image processing activities. &lt;br /&gt;
* October 16, 2009&lt;br /&gt;
**Lung CT Scans Processing. Pilot project emerged. GenerateEmphysemaMeasurements module deployed as a webservice that submits jobs to computational cluster.&lt;br /&gt;
**EM Segmentation. Familiarized with GUI steps. Started working on automation steps outlining&lt;br /&gt;
**3D Slicer and XNat interaction. Got an overview from Wendy Plesniak.&lt;br /&gt;
* October 1 - 7, 2009&lt;br /&gt;
**Selected two first priority Projects: EM Segmentation of brain MRI images; Lung CT Scans Processing (COPD Study)&lt;br /&gt;
**Got initial outline of user requirements and design specs&lt;/div&gt;</summary>
		<author><name>Azaitsev</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=70203</id>
		<title>Projects:ARRA:SlicerWF</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=70203"/>
		<updated>2011-08-09T14:10:44Z</updated>

		<summary type="html">&lt;p&gt;Azaitsev: /* All Hands Meeting Pages */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Projects:ARRASuplements|Back to Slicer ARRA home page]]&lt;br /&gt;
= Aim =&lt;br /&gt;
Supplement 3D Slicer and Extensible Neuroimaging Archive Toolkit (XNAT) with workflow management system. Provide integration and interoperability between 3D Slicer, XNAT Services and 3-rd party image processing applications and high performance computing systems. Implement it as within currently developed Structural Planning and Implementation in Neurological Exploration (SPINE) System.&lt;br /&gt;
&lt;br /&gt;
= SPINE Project Documentation =&lt;br /&gt;
[http://cni.bwh.harvard.edu/projects/spine/index.html SPINE Docs]&lt;br /&gt;
&lt;br /&gt;
= Presentations =&lt;br /&gt;
* Segmentation Workflow. PECS University Social Cognition Study.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:SlicerWF_NAC_PECS_Workflow.pdf]]&lt;br /&gt;
* EAB10_ARRA Annual Progress Report Slides.&amp;lt;br&amp;gt;&lt;br /&gt;
[[media:EAB10_ARRA_WF_2011_Zaitsev.ppt | Service Oriented Solutions for 3D Slicer. EAB10_ARRA_WF_2011. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:EAB10_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:NAMIC_ARRA_WF_2011_Zaitsev.ppt  | NAMIC Annual Report 04/2010-03/2011. NAMIC_ARRA_WF_2011_Zaitsev. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:NAMIC_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:Slicer_WF_Slicer4CARMAWorkflow.ppt  | CARMA Workflow. Cardiac Ablation Followup. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:Slicer_WF_Slicer4CARMAWorkflow.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* CARMA Project Beta release Demo Location: http://cni29.bwh.harvard.edu/SlicerWFDemo/index.php&lt;br /&gt;
&lt;br /&gt;
* Segmentation Workflows: Screenshots, scans' and study description : [[File:SlicerWF_EMSegmentProjectsReview.zip]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
= All Hands Meeting Pages =&lt;br /&gt;
* MIT 2011 Summer:&lt;br /&gt;
 Workflows Project [http://www.na-mic.org/Wiki/index.php/Summer_project_week_2011_Workflows_SOA MIT_2011_WorkFlow]&lt;br /&gt;
 Segmentation Project (MS Lesions)[http://www.na-mic.org/Wiki/index.php/2011_Summer_Project_Week_Customizing_EMSegmenter_pipelines_for_brain_lesions MIT_2011_LesionsSegmentation]&lt;br /&gt;
* Salt Lake City 2011 Winter [http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA SLC_2011_WorkFlow]&lt;br /&gt;
* MIT 2010 Summer [http://wiki.na-mic.org/Wiki/index.php/Summer_project_week_2010_Workflows_SOA MIT_2010_WorkFlow]&lt;br /&gt;
&lt;br /&gt;
= Research Plan =&lt;br /&gt;
*Create a stand-alone SPINE desktop agent with fully functional data exchange and communication mechanisms towards 3D Slicer and XNAT.&lt;br /&gt;
*Develop Service Oriented Architecture (SOA) SPINE System that will include 3D Slicer image processing modules deployed as web services as well as a workflow management system to orchestrate interaction between 3D Slicer, XNAT, and 3-rd party tools.&lt;br /&gt;
*Implement two-way control and communications between 3D Slicer and SPINE modules.&lt;br /&gt;
*Adapt SPINE System for cluster and grid computing scenarios.&lt;br /&gt;
*Provide with workflow and 3D Slicer web service wrappers editing tools.&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:UseCaseScenarios| Use Case scenarios]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PETCTWorkflow| PETCTWorkflow]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:AgingStudySegmentation| AgingStudySegmentation]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:TwoTensorTractography| TwoTensorTractography]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:LongitudinalMultimodalityRegistrationSuite| LongitudinalMultimodalityRegistrationSuite]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:MigrationJavaClients2QT| MigrationJavaClients2QT]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PediatricMSSegmentation| PediatricMSSegmentation]]&lt;br /&gt;
*[[DBP3:Utah:RegSegPipeline| MRI-based study and treatment of atrial fibrillation]]&lt;br /&gt;
&lt;br /&gt;
= Application Server / Workflow Engine Downloads =&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:WFEngineDownloads| Download Links]]&lt;br /&gt;
&lt;br /&gt;
=Key Personnel=&lt;br /&gt;
* Charles Gutmann, MD., 4%,  9-17-2009 through 9-16-2011&lt;br /&gt;
* Alexander Zaitsev, Ph.D., 75%, 9-17-2009 through 9-16-2011 &lt;br /&gt;
&lt;br /&gt;
=Annual Progress Statements =&lt;br /&gt;
'''2010-11''' &amp;lt;br&amp;gt;&lt;br /&gt;
The  April 2011 – March 2011 period was devoted on developing portable workflow solutions that can be deployed on end-users' workstations or notebooks with minimal or no system administration activities. This is in contrast to the server-side deployment. The following scenarios had been deployed and used for actual projects that require the following types of workflows: PET/CT registration and computation of biomarker driven brain physiological activities, Brain MRI Images segmentation,  MRI and MRI Angiography images pre-processing for cardiac ablation outcome estimation. Some  workflows (like EM Segmentation) had been utilizing various scenarios, some research projects  (like evaluation of chemotherapy outcome) require two types of workflows to assess physiological and structural changes. Starting from the 4th Quarter of 2011, the migration project had been emerged in order to embed Workflow GUIs into newly developed Slicer4 Suite. The existing rich client Java GUI applications are being re-written as C++/QT Sliceletts units, new modules (such as cardiac ablation project support) are had been written from scratch. The latter are being deployed from the Slicer4 GUI and act at a liaison between Slicer4 and Application Server containing  workflow and Slicer modules deployed as services. The feedback from the end users indicates that Workflow approach for the complex processing improves productivity, aids to the processing standardization and contributes to the overall experience using 3D Slicer&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
=Quarterly Progress=&lt;br /&gt;
&lt;br /&gt;
* '''2d Qtr, 2011''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study: Second release deployed. &lt;br /&gt;
*** End-users completed the first Project and currently analyzing SUV values and clinical data&lt;br /&gt;
*** New features added: Human Brain Hemispheres segmentation, Scull-stripping for total SUV counts calculation, Flexibility of custom designed label look-up table usage (users can define ROI notation according to the Project needs)&lt;br /&gt;
&lt;br /&gt;
** Left Atrium Ablation Assessment (CARMA Project)&lt;br /&gt;
*** Completed workflow pipeline for automated pre-processing and manual intervention&lt;br /&gt;
*** Developed front-end GUI for the CARMA Project support in Slicer4.&lt;br /&gt;
*** Run the workflow with the end users during NAMIC Project Week&lt;br /&gt;
*** Evaluated feasibility of left atrium wall and post-ablation scar segmentation using Robust Statistical Segmentation (RSS). Identified necessary processing controls with RSS module designers&lt;br /&gt;
&lt;br /&gt;
** Multiple Sclerosis CLIMB Study&lt;br /&gt;
*** Reprocessing for lesion segmentation&lt;br /&gt;
*** Developed Web-based (Java EE 6) application for submitting cases to the workflows for EM Segmentation of MPRAGE and registration to PD/T2/FLAIR images (60% completion)&lt;br /&gt;
&lt;br /&gt;
** EM Segmentation: &lt;br /&gt;
*** Upgraded EM Segmentation services to Slicer 3.6.4&lt;br /&gt;
*** Added brain hemispheres segmentation module to the workflows (used for PET/CT Longitudinal study)&lt;br /&gt;
*** Work with EM Segmenter module developers on building pipelines for white matter lesion segmentation (work in progress)&lt;br /&gt;
&lt;br /&gt;
** Plans for the 3rd quarter&lt;br /&gt;
*** Migrate CARMA Project workflow to end-users&lt;br /&gt;
*** Packaging of Slicer4 Workflow modules and Slicer4 custom build distribution &lt;br /&gt;
*** Completion of Web-base segmentation and registration suite&lt;br /&gt;
*** Users and Developers Documentation&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* NAMIC Annual Progress Slides (April 2010 - March 2011):&lt;br /&gt;
&lt;br /&gt;
* '''1st Qtr, 2011''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study: Second release is under testing by end-users. &lt;br /&gt;
*** Added MRI registration to aid ROI drawing on PET scans&lt;br /&gt;
*** Improved SUV results reporting and added flexibility to update ROI lookup table&lt;br /&gt;
*** Automated EM Segmentation of MRI images for computing SUVs for white matter, CSF, and whole brain (80% completion)&lt;br /&gt;
*** Integration with SPECTRE scull stripping module (70% completion) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** EM Segmentation: Automated WF Pipelines are created &amp;lt;br&amp;gt;&lt;br /&gt;
*** Flexible atlas selection (Pediatric, etc) feature added&lt;br /&gt;
*** Workflows implemented for EM Segmenter 3.6.2 and 3.6.3 (1st Qtr 2011 release)&lt;br /&gt;
&lt;br /&gt;
** Cardiac ablation results follow-up: Workflow for registration and ROI selection of cardiac MRI and MR Angiography &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Wrokflow and Web Services for prospective DTI tractography modules (currently written as Matlab modules at PNL) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Web Services for SPECTRE Scull stripping module&lt;br /&gt;
*** Accuracy and performance tuning&lt;br /&gt;
*** 50% completion&lt;br /&gt;
&lt;br /&gt;
** Migration Front End GUI to Slicer4/QT:&lt;br /&gt;
*** EM Segmentation&lt;br /&gt;
*** Cardiac Ablation Study&lt;br /&gt;
&lt;br /&gt;
** DICOM Uploader and Desktop Browser for XNat Image repository (alpha version - tested for MGH MS Center studies, proposed to use with MI2B2 Clients and Services)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''4th Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study and EM Segmentation for Aging Study are deployed at end-user sites and actively used for research. &lt;br /&gt;
** Adopted EM Segmentation preprocessing pipeline for HIV Study: high resolution SPGR images, integration with FreeSurfer brainmask extraction outputs; integration of Slicer SPECTRE module for brainmask extraction is in progress.&lt;br /&gt;
** The following post-release upgrades had been implemented based on end-user feedback: Application Server basic controls are performed from Rich Client GUI as alternative to traditional IT administration activities. The controls are implemented on point-and-click bases and include web services and workflow application deployment and upgrades, application server start and stop as well as warning end user when the server is not accepting request.&lt;br /&gt;
** Added DICOM downloads and results uploads of PET/CT pipelines from and to XNat Repository&lt;br /&gt;
** Created Services and Workflow for Matlab Prototypes modules. Case Study: tractography for DTI images&lt;br /&gt;
** Extended XNAT integration services:&lt;br /&gt;
*** Browsing capabilities of XNat data repository from the Workflow Applications&lt;br /&gt;
*** Improved DICOM upload and download performance&lt;br /&gt;
*** Added Metadata organizing services for uploaded DICOM images: header data extraction, image snapshots creation. &lt;br /&gt;
** Started project for Rich Client GUI migration from Java desktop application to build into SLicer4 QT modules. This affects mostly front-end GUI and has the following approaches: distribution with the Slicer4, end-user will select desired workflow application from Slicer4 menu while QT-written modules provide with the same functionality as Java Rich Clients. Case Study for the Migration process: registration suite for longitudinal studies that include multi-modality images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* '''3d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Concentrated on building downloadable workflow applications that could run both in desktop (new) and server environment, and that require minimum IT administrative resources. The desktop deployment is in compliance with Slicer3 general deployment concept.&lt;br /&gt;
*** The following use case scenario had been chosen: PET/CT image processing for longitudinal studies, EM Segmentation for longitudinal Aging Study.&lt;br /&gt;
** Released workflow application for PET/CT image processing for longitudinal studies. Provided end users with training and documentation.&lt;br /&gt;
*** The PET/CT processing workflow was designed to be a general application used whenever both structural patterns and metabolic activities are within the research scope. &lt;br /&gt;
*** The desktop version is tuned to use minimal computer resources, so the automates processing instances do not interfere with human activities. Automated activities may include, for example, registration and PET scan's standard uptake values computing, and manual human activities may include image cropping, quality control, and labeling voxels of interest.&lt;br /&gt;
** Core services and EM Segmentation preprocessing workflow was build for retrospective Aging Study. Tuned the Slicer3 webservices for processing low grade images acquired in mid 90s. Entire workflow is implemented with Slicer3 only modules and can be deployed locally and on the servers. Usage of Service Oriented Architecture (SOA) as a core technological approach allowed reusing most of the web services that had been build for PET/CT project. &lt;br /&gt;
** Continued embedding Slicer3 application and modules into previously released processing pipelines: replaced MIPAV with Slicer3 GUI for lesion assessment step in the multi-center Pediatric MS Cohort image processing &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''2d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Completed Social Cognition Workflow Implementation. This includes EM Segmetnation pre- and post-processing pipelines, data tracking, and integration with 3d party image processing utilities, as well as processing results acquired manually with Slicer GUI.  &lt;br /&gt;
** Multi-modality image registration and ROI selection/alignment workflow for longitudinal studies. &lt;br /&gt;
*** Use case: PET/CT image processing for longitudinal studies. &lt;br /&gt;
*** Build portable library of Slicer modules as web services and workflow that are deployed and run on a end-users' worksatations without utilization of SPL and other servers. The web services include novel Slicer3 modules, such as BRAINSFit and BRAINSResamle &lt;br /&gt;
*** Started working with Slicer3 developers on Slicer 3.8 GUI wizard to communicate with workflow instances.&lt;br /&gt;
** Participated at NA-MIC Summer 2010 Project Week: [[Summer_project_week_2010_Workflows_SOA]]&lt;br /&gt;
&lt;br /&gt;
=Progress=&lt;br /&gt;
* August 1, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT&lt;br /&gt;
* Follow-up with end users with new Study setup&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
CARMA Project&lt;br /&gt;
* Documentation (Work in progress)&lt;br /&gt;
* Plans for next week: custom packaging (Mac Snow Leopard 64 bit), building extension, documentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation&lt;br /&gt;
* Stress-test of online segmentation requests suite for  [http://www.slicer.org/slicerWiki/index.php/EMSegmenter-Tasks#Additional_Use_Cases CLIMB Study](for BWH MS Center)&lt;br /&gt;
* Reason for building online suite: the Group is Using mostly MAC OS Tiger machines for legacy reasnos, the most recent Slicer3 builds as well as QT don't work on those machines (QT4.x runtime could not be installed).&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* July 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA Project&lt;br /&gt;
* Documentation (Work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation&lt;br /&gt;
* Work on alpha-release of online submission of segmentation requests (for BWH MS Center)&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* July 22, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
Vacation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* July 8, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
3D Slicer in General and CARMA Project&lt;br /&gt;
* Presentation and life demo at Cardiology Research Center (Moscow, Russia) [[File:RussianCardiologyCenterCARMA2011.ppt]]&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* July 1, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA V1.0&lt;br /&gt;
* Migration to new QT building environment (Mac 10 Snow Leopard). &lt;br /&gt;
* Building custom package. Issues: new features (not only WF related) are not shown on the menu of the resulting application&lt;br /&gt;
* Comparing preprocessing workflow results with published in literature data (our module produces better alignment)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*June 24, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
Project Week:&lt;br /&gt;
* Testing RSS module for left atrial wall scar segmentation&lt;br /&gt;
* Testing EM Segmenter for lesion detection on PD (requested by end-users) and FLAIR images&lt;br /&gt;
&lt;br /&gt;
EM Segmentation &lt;br /&gt;
* Web-based segmentation and registration module for MS Center. Goal: facilitate 3D SLicer modules for the cases that could not be processed with in-house build DTS+ algorithm&lt;br /&gt;
* Pipeline: Segment MPGR or T1 (user's choice), Register MPGR to PD/T2, Resample Segmentation Map to PD/T2. Completion: 60-70%.&lt;br /&gt;
* The rest will be done manually or via lesion segmentation with EM Segmenter.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* June 17, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
Preparation for Project Week&lt;br /&gt;
&lt;br /&gt;
* June 10, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
CARMA V.1.0&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code completed and tested&lt;br /&gt;
* Packaging as extension is pending (Subject for Summer 2011 Project week)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Debugging consolidation results issue(SUVs for manual and automated segmentation) &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* June 3, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Deployed on end-user's machine&lt;br /&gt;
* TODO next week: fix SUV results consolidation issue (when MRI segmented ROI got SUV computed for some subjects, only those subjects' SUVs are being added into consolidated report. &amp;quot;Raw&amp;quot; SUV values per subject are generated as expected)  &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 27, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Ready for deployment. New Features: hemispheres EM Segmentation, automated ICC/brainmask extraction using EM Segmenter, fixed controls for MRI conversion and registration&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 20, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General / PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Hemispheres EM Segmentation - adjusted for required label lookup table&lt;br /&gt;
* Use cases added for EM Segmenter General Project: http://www.slicer.org/slicerWiki/index.php/EMSegmenter-Tasks#EMSegmenter_use_cases&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SPECTRE Scull Stripping&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* The new version to be tested on coming week (After PETCT MRI processing migrated to Hemispheres scenario )&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* May 13, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General / PETCT V1.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Hemispheres EM Segmentation - technically works with labal values hardcoded in Slicer EM Segmenter - need to add manual label value edition step&lt;br /&gt;
* PETCT WF Cut for Java GUI (Pending Hemispheres label update completion). Next release will be in QT4.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* May 6, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (QA of EM Segmenter module, work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* April 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Open Discussion for Packaging WF QT Modules as Slicer4 extensions (waiting for SOPs)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review supported projects http://wiki.na-mic.org/Wiki/index.php/File:SlicerWF_EMSegmentProjectsReview.zip &lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (required by Study)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Slicer Modules General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Standardizing Crop Volumes Output (with A. Fedorov's module). Review for required updates of existing product (PET/CT, CARMA)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Open Discussion for Packaging WF QT Modules as Slicer4 extensions (waiting for SOPs)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review supported projects http://wiki.na-mic.org/Wiki/index.php/File:SlicerWF_EMSegmentProjectsReview.zip &lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (required by Study)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Slicer Modules General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Standardizing Crop Volumes Output (with A. Fedorov's module)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 22, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Beta release ready. Demo Location: http://cni29.bwh.harvard.edu/SlicerWFDemo/index.php&lt;br /&gt;
* TODO: Tutorial. Original inputs copy/renaming&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 15, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Adding App server auto-config features&lt;br /&gt;
* Finalizing the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 08, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Second release beta build tested on cosutmer side &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review registration quality (with Dr. Meier). Angiography images' Resampling tuned. &lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 01, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the second release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
XNat Integration&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* (Java) GUI for Project Browsing and DICOM Series Upload. Post-upload DICOM processing tested and debugged&amp;lt;br&amp;gt;&lt;br /&gt;
* Ready for integration with mi2b2 client.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Migrated to Latest Slicer 3.6.3 stable release: only the Input scene had to be updated, the API remained the same&lt;br /&gt;
* Tested EM Segmenter with CMTK4Slicer extension - processing takes to much time on Linux_64bit machine, rolled back to BRAINSFit registration. When used on Mac OS X build, the Slicer could not start (bug report 1126).&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SPECTRE Scull Stripping:&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Testes for various use cases: the module is extremely sensitive to T1 MRI quality (does not work for most MRIs from PET/CT project&lt;br /&gt;
* TODO next week: check for FLAIR images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Slicer4 QT GUI and Cropping activity in progress.&amp;lt;br&amp;gt;&lt;br /&gt;
* Tried direct MRA to MRA registration option: resampling with LMRI registration transforms works better.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Extra VOI labels revised&lt;br /&gt;
* Debugging of SUV results' renormalization step&lt;br /&gt;
* TODO: ICC extraction / whole brain total uptake computing; EM Segmentation for R_WM, L_WM SUV computing and BPH estimation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SCULL STRIPPING/SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Installed and tested CLI option on Linux_64bit platform&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Workflow interruption before BSPline registraton: BPEL Module completed. Slicer4 QT GUI and Cropping activity in prorgess.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Implemented and Tested with end-users proposed changes: denormalization of SUV results, adding more VOI labels, added FLAIR MRI in addition to T1s for VOI drawing&lt;br /&gt;
* Tested manual ICC extraction using PET scans: works satisfactory with island removal and cropping followed by threshold level labeling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4&lt;br /&gt;
* Change proposed: interrupt workflow after affine registration and have user crop the VOI. This is to prevent excessive deformations for BSpline registration and resampling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4. User has option to choose the atlas that fits better for the given subject (NOTE: hardcoding must be rewritten for atlas linking)&lt;br /&gt;
* PETCT test - the problem is that T1s are low resolution and with contrast. Proposed using T1s without contrast&lt;br /&gt;
* PETCT change request: users wants to compute SUV for entire ICC. Had demo how to segment brainmask/ICC using PET scan. The derived brainmask label can be used for SUV computation.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - cmpleted&lt;br /&gt;
* Sample cases run - excessive deformation after BSpline registration hase&lt;br /&gt;
* Next week plan - pull tuning controls to front-end of pipeline API, start working of QT module for CARMA registration&lt;br /&gt;
* May consider other than BRAINSFit registration modules&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Design plan for change request: more VOI labels, add FLAIR in addition to T1 for VOI drawing, T1s segmentation&lt;br /&gt;
* Tested segmentation for sample cases - artifacts from poor quality MRIs lead to exclusion of parts of ICC from segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Completed troubleshooting of EMSegmenter module calling from Java (need TCL libs to be pulled from Slicer environment)&lt;br /&gt;
* Tested EMSegmenter autoruns for HIV and Pediatric MS patiens. Work as expected, subject to improvement of PED MS case segmentation by building better skull/neck/air atalses&lt;br /&gt;
* Suggested usage of two subsets of atalases: with and without neck. The Subject MRIs have to be cropped accordingly or best fit atlas has to be selected&lt;br /&gt;
* Made no-neck cropped atlas collection for default EMSegmenter scenario&lt;br /&gt;
* Tested with PET/CT study MRI cases - see above &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - in progress&lt;br /&gt;
* Next week goal - have back end processing ready&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Longitudinal Study&lt;br /&gt;
* Added MRI registration to the pipeline&lt;br /&gt;
* Troubleshooting of complex XML schema issues on Linux machines (some modules working on MAC do not work on Linux). As a workaround - did not include MRI convert and register part into base BPEL module. Used separate services (transparent for end-user)&lt;br /&gt;
* TODO next week for change request completion: explicit pixel type casting for MRI in BRAINSFit, VOI MRML scene update (currently MRI added on top of schema)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* February 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipeline for Pediatric MRI. Same scenario as for HIV Project, icbm pediatric atlases (Completed, verified)&lt;br /&gt;
* Collected NIH healthy brain development atlases: various age ranges from 4.5 to 18 yo. Converted to Slicer readable format &lt;br /&gt;
* Work on web services for the new automated EM Segmenter module (release Nov 10 - current). Verified task completion both for adult and pediatric images. Discussed tuning parameters for work load balance on workstations.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Started working on MRI registration to the reference CT scans. &lt;br /&gt;
* Design specs for optional White Matter segmentation for SUV computing.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* February 4, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipelines for Pediatric MRI (in progress)&lt;br /&gt;
* Adapting Pediatric T1 atlases for &amp;quot;Human Brain&amp;quot; build-in EM Segmentation wizard (in progress)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 28, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Verifying EM Segmenter module for latest builds and HIV/PED MS Studies (report pending)&lt;br /&gt;
* Work with SPECTRE module developers with pediatric MRI brainmask extraction&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* January 21, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Compiling plan for WF FrontEnd GUI migration to Slicer4/QT Widgets&lt;br /&gt;
* Preparing for annual progress report&lt;br /&gt;
&lt;br /&gt;
* January 14, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI: Integrated into the Slicer4 as Slicelet (or thin Client)&lt;br /&gt;
* Participation at AHM-2011, discussing integration of SPECTRE module and updated approach to EM-Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA&lt;br /&gt;
&lt;br /&gt;
* January 7, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* HIV project workflow delivered. Major additions relate to user convenience: &lt;br /&gt;
- Project-specific parameter settings, importing T1s and brainmasks from FreeSurfer outputs with conversion to NIFTI, resampling brainmask to original scans and automatied subject addition.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Follow up with end user: need to add MRI scans, if available, addition and registration to CT in order to ease VOI drawings.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
 &lt;br /&gt;
* December 31, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Follow-up with user Experience for AGING Study Segmentation (Positive feedback)&lt;br /&gt;
* Target date for HIV project delivery - next week&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Self-training for QT widget development&amp;lt;br&amp;gt;&lt;br /&gt;
* Outlined Workflow Rich Clients migration strategy from Java to QT/Slicer4:&amp;lt;br&amp;gt;&lt;br /&gt;
** Use Java Stubs (similar to SPECTRE integration) or file binding for envocation of workflow pipelines. (See SOAP remark below)&lt;br /&gt;
** Direct Web Servisec calls must be wrapped into REST protocol. The reason: NON-commerchial QT kit does not include SOAP protocol for web servises.&lt;br /&gt;
** The GUI will be implemented as page widget or QT dialog GUI forms called from within Slicer4.&lt;br /&gt;
** Communications between Slicer4 and WF GUI will be set via child-parent and signal-slot relations&lt;br /&gt;
* Worked on a Prototype for Basic EM Segmentation QT widget (70% complete). Will work on integrtion with SLicer4 during the AHM-2010&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
XNAT Integration&lt;br /&gt;
* Debugged XNAT RESTFul API usage for uplaoding DICOM series followed by header data extraction and image snapshots creation&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Added compensation for failed atlas registration (subject for old poor quality pseudo-T1 images): blank probability maps are created in case of failure.&lt;br /&gt;
* Data preparation module for FreeSurfer data import near completion. Expected time for deployment at end-users workstations - first week of January&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Discussed strategy for EM Segmentation pipeline solutions collection (K. Pohl, R. Kikinis)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* RE-using the same core workflow as for 1-channel EM Segmentation of AGING STUDY cases&lt;br /&gt;
* Added data input preparation module: ICC label mask preparation and skull-stripping based on FreeSurfer brainmask output volume.&lt;br /&gt;
* Two-channel EM segmentation pipeline (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE / GENERAL Development &amp;lt;br&amp;gt;&lt;br /&gt;
* Worked on plans for migrating fro rich workflow Java clients to embedded workflow windows inside the Slicer.&amp;lt;br&amp;gt;&lt;br /&gt;
The embedded workflow management clients are to be implemented with QT/PyQT toolkits&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
INTEGRATION WITH XNAT:&amp;lt;br&amp;gt;&lt;br /&gt;
* Automated DICOM series upload with triggering DICOM headers parsing at XNat site (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress. &lt;br /&gt;
- Results upload to XNat (Completed) &amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat based on user's input (Project + Subject + PET or CT session / scan) (Completed)&amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat - perfomance boosting solution for downloads found , web services services are created, relinking for the client side in progress &amp;lt;br&amp;gt;&lt;br /&gt;
- Xnat querying for subjects and automated subject addition into the workflow (In Progress) &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-segmentation module added for auto correction of segmentation results. Particularly - relabeling CSF voxels segmented as Air inside the intracranial cavity. This was requested by end-users after processing images with zero-signals in CSF voxels &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting automated dual-echo DICOM images conversion and split into two NRRD volumes&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT / EM Segmentation pipeline:&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting memory allocation issues for scull-stripping module SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
COPD Project:&amp;lt;br&amp;gt;&lt;br /&gt;
* Benchmark test for accelerated DICOM downloads from XNat (remoote XNat Central server): we can handle at least 6 cases (4 CT scans in each) per hour, which is compatible with current workload quotes on SPL cluster processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* December 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Deployed Version 1. &amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Test project chosen as a closest match to registration scenario: Pediatric MS Cases from MGH - requires periodic image preview for different &lt;br /&gt;
modalities taken from vaious time points. Label maps for VOIs resampling is also required.&lt;br /&gt;
&lt;br /&gt;
* November 26, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user. Version 1 is complete&amp;lt;br&amp;gt;&lt;br /&gt;
* Started working on integration with XNat&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on input data organizing modules&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 19, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user (70% done)&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Universal Registration Workflow for Longitudinal Studies - design specs in progress&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 12, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Minor tuning to EM Segmentation template as of users' feedback&lt;br /&gt;
* Users started using the workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed input data conversion from Genesis to Slicer native or NIFTI format. Our help may be needed in input data organizing.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Tuned application according to co-laborators (PNL) needs&amp;lt;br&amp;gt;&lt;br /&gt;
* The webservices and BPEL workflow application are tested ready to accept computation requests from PNL case tracking system &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Discussed Universal Registration Workflow for Longitudinal Studies&lt;br /&gt;
* Started the thread about possible cooperation with Children hospital's image processing pipelines and integration with Xnat &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 5, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Webservices and workflow pilot project created and deployed on Psychiatry Neuroimaging Laboratory subnet &amp;lt;br&amp;gt;&lt;br /&gt;
* The V.1.0 deployment is scheduled for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 29, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Most of functionality is completed. Some volume statistics post processing is pending&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL EM SEGMENTATION Pipeline: &amp;lt;br&amp;gt;&lt;br /&gt;
* The SPECTRE scull stripping module. Started integration into EMS workflow. Made some test runs from Slicer GUI&amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Identified as a candidate for Workflow Application&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 22, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* All back-end functionality are implemented&amp;lt;br&amp;gt;&lt;br /&gt;
* EM Segmentation scene usability is confirmed by end-user&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for next week: add Label Statistics computation for CSF/Brain/ICC &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 15, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* The latest (October) builds of Slicer 3.6.2 produced acceptable results. This was verified by the target users. The EM Segmentation will be performed on Slicer 3.6.2 or later&amp;lt;br&amp;gt;&lt;br /&gt;
* The new Web services had been created and added to the pipeline as optional processing steps: Biasfield correction (implement novel N2ITKBiasFieldCorrection module) and Volume's scalar datatype casting (as workaround for Biasfield correction module not preserving image scalar datatype - the bug is filed) &amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed the Front-End GUI design with target users. The design pattern is taken from the PETCT project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 8, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-deployment support. Tuned CT registration as of user's feedback.&lt;br /&gt;
* Adapting to the Single Slicer build: Slicer 3.6.2. Found label duplicates in the label lookup table - will ask user if it's tolerable. Waiting for the Slicer 3.6.2 build that contains all required modules. Rolling back label tag appending code for SUVs - the latest Slicer build appends the tags.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Resumed development. The priorities are set for usage of Slicer 3.6.2 - subject for EM Segmentation scene tuning. Continued coding for Scene creation for Slicer 2.8 - as a backup option for ongoing research project.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 1, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized V1.0 release based on end-user feedback: updates relate mostly to error proofing and SUV values representation&lt;br /&gt;
* Post-deployment support. Users pre-processed first set of patients &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* September 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* System deployed and tested at End Users' site.&amp;lt;br&amp;gt;Users are trained to perform all tasks required by the workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
* Got positive feedback with suggestions on Slicer Scenes' layouts improvement and PET scans' SUV (standard uptake values) results display&lt;br /&gt;
* Two distribution packages are assembled: Lunix and MAC OS versions. The difference in two packages is in specific Slicer3.6/3.7 builds - subject to Slicer Linux builds debugging.&amp;lt;br&amp;gt; As a workaround for Linux deployment - multiple Slicer builds are used to perform various tasks (registration, opening editing scenes in Slicer, SUV computing)&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for coming week - finalize V1.0 release based on end-user feedback&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Embedded SUV computations into the workflow (as system calls - will be translated into web service later)&amp;lt;br&amp;gt;&lt;br /&gt;
* Pre-release demo for end users.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Create and debug EM Segmenter scenes template for Slicer 3.6 and 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* September 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation - workflow pipeline and deployment verified&amp;lt;br&amp;gt;&lt;br /&gt;
* Tested EM Segmentation scenes within Slicer 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
* Started migration of EM Segmentation to Slicer 3.6. Discovered issues had been reported to EM Segmenter module designers &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* August 29 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation completed. Preprocessing Pipleine completed 80% (subject for input registration parameters tuning) &amp;lt;br&amp;gt;&lt;br /&gt;
* Most webservices (for registration and resampling steps) had been taken and re-used from PET/CT ROI/Longitudinal Study - showing the advantage of service-oriented software design and deployment.&lt;br /&gt;
* Continued on distribution and deployment of the service/workflow applications: on PET/CT and AGING STUDY projects.&lt;br /&gt;
&lt;br /&gt;
PEDIATRIC Multiple Sclerosis Cohort. Support of multi-center distributed processing project&amp;lt;br&amp;gt;&lt;br /&gt;
* Introduced Slicer 3.6 for the MS Lesion Assessment step performed at Mayo Clinic. Images are being transferred from image repository at BWH and automatically opened and arranged within Slicer GUI for reading.  This was replacement of Client GUI using MIPAV that stopped working on new computers at Mayo Clinic.&lt;br /&gt;
The images are being loaded via generated MRML Scenes same way as in PET/CT and AGING STUDY projects &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* August 22 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Preprocessing pipeline merge with SUV computations &amp;lt;br&amp;gt;&lt;br /&gt;
- QA for SUVs computation was performed by Wendy Plesniak for images with known uptake values. &amp;lt;br&amp;gt;&lt;br /&gt;
- Discovered that image cropping step (not related to automated registration pipeline and SUVs computing) smoothes the images by doing interpolation when used with default settings. Got suggestions from Steve Piper using Nearest-Neighbor interpolation (&amp;quot;no interpolation&amp;quot;) for a time being&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
- This is the new project candidate. Requested for the images with failed manual segmentation and/or segmentation with FreeSurfer. The EM Segmentation run showed most acceptable results on one of the problem images back in February &amp;lt;br&amp;gt;&lt;br /&gt;
- The workflow will be developed and deployed similar to PET/CT ROI Longitudinal study approach - all preprocessing steps will be done with Slicer modules, all runs will be performed on local end-user machines.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
 &lt;br /&gt;
&lt;br /&gt;
* August 15 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- First 5 cases with 3-4 time points preprocessed for SUVs computation&lt;br /&gt;
&lt;br /&gt;
* August 8 2010&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Testing of installation and operation at users' site (Performed by Wendy Plesniak)&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* July 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Delivered beta version of registration pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
- Prepared installation and user manuals &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* June 11, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Registration modules completed &amp;lt;br&amp;gt;&lt;br /&gt;
- Irregular cases registration problem solved (when whole body and brain only scans are mixed for a timepoint)&amp;lt;br&amp;gt;&lt;br /&gt;
- Live demo of case setup and registration workflow for end users. Real case with 4 timepoints used&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Coming week plans&amp;lt;br&amp;gt;&lt;br /&gt;
- Adjust workflow based on end users' feedback&amp;lt;br&amp;gt;&lt;br /&gt;
- Integration with SUVs computing for PET scans&amp;lt;br&amp;gt;&lt;br /&gt;
- GUI for workflows dispatching and data organizing&amp;lt;br&amp;gt;&lt;br /&gt;
- (TBD) Integration with 4D time series analysis Slicer module&amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
* May 28, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- Migration to the latest Slicer 3.6 release candidate &amp;lt;br&amp;gt;&lt;br /&gt;
- Added webservice for new registration module: BRAINSFit &amp;lt;br&amp;gt;&lt;br /&gt;
- Test runs for new patients with 4 timepoints' scans &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Plans for next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI &amp;lt;br&amp;gt;&lt;br /&gt;
- processing workflow demo for end user &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 21, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Pilot version of portable web services and automated workflow tested: &amp;lt;br&amp;gt;&lt;br /&gt;
Linux: workflow and visual review passed&amp;lt;br&amp;gt;&lt;br /&gt;
Stress test for 25 timepoints passed &amp;lt;br&amp;gt;&lt;br /&gt;
MAC OS: workflow passed, visual review failing when PET/CT images are loaded into GUI simultaneously (bug report submitted)&amp;lt;br&amp;gt;&lt;br /&gt;
Windows: need to adapt command line modules and workflow management system to sygwin environment&amp;lt;br&amp;gt;&lt;br /&gt;
Plans for next week: integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI&lt;br /&gt;
&lt;br /&gt;
* May 7, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Selected registration and resampling modules with more precise and stable outputs. &amp;lt;br&amp;gt;&lt;br /&gt;
Started building portable web services and automated workflow &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 30, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- manual walk through the processing steps: ROI cropping, registration/resampling, PET pharmaceutical DICOM data retention. &amp;lt;br&amp;gt;&lt;br /&gt;
- testing workflow and web services packages distribution to end-users' machines&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* April 23, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : testing various registration and re-sampling algorithms (work in progress)&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation: as of collaborators' request, run existing EM Segmentation workflow for older low resolution pseudo-T1 images. The EM Segmentation works for those images with manual sampling. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 16, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
  Social Cognition Study: started Cortical Thickness Measurement module build (bases on NA-MIC ARCTIC pipeline) &amp;lt;br&amp;gt;&lt;br /&gt;
  PET/CT ROI/Longitudinal Study Registration : Design specs, PET-to-CT images registration tests on training data. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 9, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. GUI update based on end-user experience.&amp;lt;br&amp;gt;&lt;br /&gt;
User request: automated label maps' volumes calculation (Currently possible from Slicer3 GUI)&amp;lt;br&amp;gt; &lt;br /&gt;
PET/CT ROI Project. Initial design specs discussion with end-users and co-developers&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure&lt;br /&gt;
Verification of segmentation workflow GUI: from registering new case to reviewing results&amp;lt;br&amp;gt;&lt;br /&gt;
Cross study test of segmentation workflow: MGH/MS Center data - success,  HIV Project data - some EM Segmentation scene tuning is needed &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*&lt;br /&gt;
* April 2, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. Segmentation workflow completed&amp;lt;br&amp;gt;&lt;br /&gt;
* Coming Week plans:&amp;lt;br&amp;gt;&lt;br /&gt;
- Document Segmentation Workflow. Follow up with end users &amp;lt;br&amp;gt;&lt;br /&gt;
- Start with Cortical Thickness and ROI-in-longitudinal studies workflows&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* March 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All essential processing and workflow interaction clients are ready.&amp;lt;br&amp;gt;&lt;br /&gt;
- Completed segmentation for 10 out of 50 patients. The remaining cases will be finalized upon manual lesion segmentation and QC verification of WM/GM/CSF and Deep GM segmentation's. &amp;lt;br&amp;gt;&lt;br /&gt;
- TODO next week: refine QC GUI and data tracking / progress monitoring schema. &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&amp;lt;br&amp;gt;&lt;br /&gt;
- New Slicer3 web services added: re-slicing with reference image volume, casting image scalar type &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
* March 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Segmentation maps Merging Services for GM/WM/CSF (Slicer EM Segemnter), Lesion (Slicer, Manual), and Deep GM (FreeSurfer)  &amp;lt;br&amp;gt;&lt;br /&gt;
- Deep GM segmentation pipeline adopted as optional service for Social Cognition Study (22 out of 50 cases processed) &amp;lt;br&amp;gt;&lt;br /&gt;
- (In progress) GUI client for Launching Segmentation results merging with optional Deep GM segmentation with FreeSurfer &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- Complete GUI Client for Segmentation result merging &amp;lt;br&amp;gt;&lt;br /&gt;
- Progress Monitoring services for entire Study processing: EM Segmenter Preprocessing, EM Segmentation, Lesion Segmentation (including human activities assignments), Deep GM segmentation, and results consolidation. &amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* March 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All 50 cases went through &amp;quot;basic&amp;quot; One-channel EM segmentation (GM/WM/CSF) &amp;lt;br&amp;gt;&lt;br /&gt;
- Basic pipeline start-up command line client created: user has two options - request brainmask extraction or provide with previously extracted brainmask for a given subject &amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison of GM/WN/CSF performed for Slicer EM Segmenter and FreeSurfer recon-all (used with default settings). &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmenter provides more accurate output &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmentation pipeline runs faster (40 minutes vs 12 hrs when no brainmask extraction requested) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO:&amp;lt;br&amp;gt;&lt;br /&gt;
- merging modules for automatic 1-channel EM segmentation and manual lesion segmentation &amp;lt;br&amp;gt;&lt;br /&gt;
- Emerge Cortical Thickness pipeline project: use NAC ARCTIC processing steps and modules &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Selected stable EM Segmentation scenario: White Matter, Gray Matter, and Cerebrospinal Fluid &amp;lt;br&amp;gt;&lt;br /&gt;
- First 16 cases are segmented for selected scenario. Nine more cases are preprocessed for EM Segmentation.&amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison to segmentation with FreeSurfer showed better accuracy for Slicer2 EMSegmenter &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure &amp;lt;br&amp;gt;&lt;br /&gt;
- Three prerpcocessed cases failed during volume ICC masking with in-house build utility. Evaluated switching to Slicer3 Mask and island removing modules.&amp;lt;br&amp;gt;&lt;br /&gt;
- Initial design specs discussion for cortical thickness measurement pipeline. ARCTIC pipeline selected. ARCTIC preprocessing steps signifficantly overlap with EM Segmentation preprocessing workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
  &lt;br /&gt;
* February 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: &amp;lt;br&amp;gt;&lt;br /&gt;
A) parameters tuning for EM Segmenter itself (work with EM Segmenter developer), template scenes creation &amp;lt;br&amp;gt;&lt;br /&gt;
B) update preprocessing pipeline - deep gray matter atlases included &amp;lt;br&amp;gt;&lt;br /&gt;
C) test and debug preprocesing pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
D) identified missing modules: atlas autocalibration for EM Segmentation scene, Island removal for ICC mask&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- Review currently deployed modules. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: reviewed firts seven subjects' outputs, added volume orientation module into pipeline (prevents ICBM atlas linear registration failures)&amp;lt;br&amp;gt;&lt;br /&gt;
- Fused ICC(brainmask) extraction module with EM Segmenter preprocessing. Three scenarious implemented: start with pre-extracted ICC mask (longitudinal studies case), run with ICC ectration, run with ICC extraction AND ICC correction before ICBM atlas preporcessing. &amp;lt;br&amp;gt;&lt;br /&gt;
- Completion of Human activities GUI (QC, ICC Correction) planned for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: Volume Orientation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: automated preprocessing pipeline for Slicer2 EM Segmenter test version deployed. Seven cases pre-processed.&lt;br /&gt;
- PET Quantitative measurements: Preliminary design specs discussion.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: BSplineRegistration (for non-linear registration), ResampleVolume2 (for atlases resampling based on image atlase templates registration). Local and Network runs are implemented, Cluster/GridWizard implementation pending.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Slicer EM Segmenter module: preprocessing design for Slicer2 EM Segmenter&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Adapting for Slicer2 EM Segmenter (mostly from pipelines and services for previous projects)&lt;br /&gt;
  -- Integration with FreeSurfer modules for bisafield correction, brainmask extraction, and linear registration of ICBM atlases&lt;br /&gt;
  -- Preprocessing updates for non-linear registration of ICBM atlases with Slicer2 (image re-orientation service designed)&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 29, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- EM Segmentaton pipeline: preprocessing results are being transferred to XNat (anonymized data, Central XNat) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Slicer EM Segmenter module: discussed agenda and scheduled a work meeting for Social Cognition Study image segmentation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Testing stage, 95% completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- SPL XNat server: verified data exchange via RESTfull web services.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 22, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Follow up with White Matter Lesion Segmenter and Scull Stripping Modules developers: Work in Progress&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Work in Progress, 60%+ completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Discussed SPINE image repository migration to XNat&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 15, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. &lt;br /&gt;
- Social Cognition Study: &lt;br /&gt;
Work-in-progress on intermediate (reconstruction) and results (resources) data storage at XNat.&lt;br /&gt;
&amp;lt;br&amp;gt;Reviewing and preparation more cases for EM Segmentor (Slicer 3.5) tuning.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* NA-MIC Project Week&lt;br /&gt;
Selecting candidate Slicer modules for other than Lesion EM Segmentation topics of Social Cognition study: Withe Matter Lesion Segmenter (UNC), Scull Stripping utility from UIOWA.&lt;br /&gt;
Reviewing issues of currently used Scull Stripping Slicer Extension and Slicer 3.5 EM Segmenter.&lt;br /&gt;
&amp;lt;br&amp;gt;XNat Data organizing training&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 1, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Preparation of Demo for NA-MIC work week: &lt;br /&gt;
- COPD Study. Added Remote pipepline start interface (represents real world scenario where Xnat repository, Processing modules and User are at different sites)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
- EM Segmentation. Added human activities steps to the workflow: ICC (brainmask) correction and EM Segmantation scena load per se.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 25, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Pilot workflow pipeline for EM Segmentation (all steps except user-activity step: ICC correction assignment and tracking)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 18, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Build and tested web services for EM Segmentation image preprocessing: DICOM-to-NRRD conversion, registration, skull stripping, image masking.&lt;br /&gt;
Started building workflow pipeline (subject to finish first version next week)&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Started Collecting Library of Slicer Build number vs. functional modules and extensions.&lt;br /&gt;
Plan for NAMIC project week: scheduled meetings for XNat data customization, Skull-stripping modules tuning, identified Social Cognition study cases that fail EM Segmentation processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 11, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Updating and verification of EM Segmentation Scenario&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Projects:ARRA:SlicerWF:UseCaseScenarios#Usecase_MS_lesion_Assessment&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Familiarizing with Slicer3.4/5 Modules required for implementation of EM Segmentation Scenario. Participation in debugging and/or usage tuning of Dicom Conversion, Registration, Skull Stripping, Masking, and Image Casting modules. &lt;br /&gt;
&lt;br /&gt;
* December 4, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Slicer3.4's EM Segmentation and Visual QC as part of image processing pipeline for Social Cognition Study for MS Patients.&lt;br /&gt;
Project emerged. EM Segmentation template creation debugged.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
Emphysema Measurements (COPD Study) - workflow stability and scalability test.&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 27, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Emphysema Measurements (COPD Study).&lt;br /&gt;
Added compensation for long running calculations and time-outs to the main computing pipeline.&lt;br /&gt;
Visual QC (work in progress)&lt;br /&gt;
** Infrastructure&lt;br /&gt;
XNat data structure customization, metadata storage, results consolidation: new feature request list creation (work in progress)&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 13, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
*** Pilot system for whole processing cycle for Emphysema Measurements (COPD Study) including the following:&lt;br /&gt;
Web query for CT session file list download&lt;br /&gt;
Pilot user interface for submitting the file list and starting processing pipeline&lt;br /&gt;
Notification about processing steps and failures&lt;br /&gt;
Upload results to XNat repository (at this stage results are uploaded into same folder where original scans are(*))&lt;br /&gt;
*** Immediate Plans&lt;br /&gt;
Complete Visual QC module&lt;br /&gt;
Design and implement meta-data transfer to XNat (including processing details and MRML files for loading images into the 3D Slicer)&lt;br /&gt;
&lt;br /&gt;
(*)Customization of results storage&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 6, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Tuned and debugged multiple subjects processing for: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat.&lt;br /&gt;
***Started working on quality control embedding into the above scenario. Plan to complete and video-record demo next week.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***Published general Product Integration scenario flow chart to collaborators' community. Discussion is open and in progress&lt;br /&gt;
&lt;br /&gt;
* October 30, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Piloted and tested the sequence: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat(1).&lt;br /&gt;
***Performance test of overall cycle: data transfer from remote serve is a bottleneck as expected&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data browsing features reviewed.&lt;br /&gt;
(1) Not automated yet&lt;br /&gt;
* October 23, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Defined COPD processing scenario with interoperability between Xnat, 3D Slicer Command Modules, Workflow, and Gridwizard Enterprise.&lt;br /&gt;
***Pilot version of Emphysema Measurements workflow pipeline deployed.&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data transfer features reviewed. Use account at XNat Central during learning curve.&lt;br /&gt;
***Feasibility test of 3D Slicer fiducials module for ROI highlights during QC and manual image processing activities. &lt;br /&gt;
* October 16, 2009&lt;br /&gt;
**Lung CT Scans Processing. Pilot project emerged. GenerateEmphysemaMeasurements module deployed as a webservice that submits jobs to computational cluster.&lt;br /&gt;
**EM Segmentation. Familiarized with GUI steps. Started working on automation steps outlining&lt;br /&gt;
**3D Slicer and XNat interaction. Got an overview from Wendy Plesniak.&lt;br /&gt;
* October 1 - 7, 2009&lt;br /&gt;
**Selected two first priority Projects: EM Segmentation of brain MRI images; Lung CT Scans Processing (COPD Study)&lt;br /&gt;
**Got initial outline of user requirements and design specs&lt;/div&gt;</summary>
		<author><name>Azaitsev</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=70202</id>
		<title>Projects:ARRA:SlicerWF</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=70202"/>
		<updated>2011-08-09T14:09:37Z</updated>

		<summary type="html">&lt;p&gt;Azaitsev: /* All Hands Meeting Pages */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Projects:ARRASuplements|Back to Slicer ARRA home page]]&lt;br /&gt;
= Aim =&lt;br /&gt;
Supplement 3D Slicer and Extensible Neuroimaging Archive Toolkit (XNAT) with workflow management system. Provide integration and interoperability between 3D Slicer, XNAT Services and 3-rd party image processing applications and high performance computing systems. Implement it as within currently developed Structural Planning and Implementation in Neurological Exploration (SPINE) System.&lt;br /&gt;
&lt;br /&gt;
= SPINE Project Documentation =&lt;br /&gt;
[http://cni.bwh.harvard.edu/projects/spine/index.html SPINE Docs]&lt;br /&gt;
&lt;br /&gt;
= Presentations =&lt;br /&gt;
* Segmentation Workflow. PECS University Social Cognition Study.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:SlicerWF_NAC_PECS_Workflow.pdf]]&lt;br /&gt;
* EAB10_ARRA Annual Progress Report Slides.&amp;lt;br&amp;gt;&lt;br /&gt;
[[media:EAB10_ARRA_WF_2011_Zaitsev.ppt | Service Oriented Solutions for 3D Slicer. EAB10_ARRA_WF_2011. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:EAB10_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:NAMIC_ARRA_WF_2011_Zaitsev.ppt  | NAMIC Annual Report 04/2010-03/2011. NAMIC_ARRA_WF_2011_Zaitsev. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:NAMIC_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:Slicer_WF_Slicer4CARMAWorkflow.ppt  | CARMA Workflow. Cardiac Ablation Followup. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:Slicer_WF_Slicer4CARMAWorkflow.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* CARMA Project Beta release Demo Location: http://cni29.bwh.harvard.edu/SlicerWFDemo/index.php&lt;br /&gt;
&lt;br /&gt;
* Segmentation Workflows: Screenshots, scans' and study description : [[File:SlicerWF_EMSegmentProjectsReview.zip]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
= All Hands Meeting Pages =&lt;br /&gt;
* MIT 2011 Summer:&lt;br /&gt;
 Workflows Project [http://www.na-mic.org/Wiki/index.php/Summer_project_week_2011_Workflows_SOA]&lt;br /&gt;
 Segmentation Project (MS Lesions)[http://www.na-mic.org/Wiki/index.php/2011_Summer_Project_Week_Customizing_EMSegmenter_pipelines_for_brain_lesions]&lt;br /&gt;
* Salt Lake City 2011 Winter [http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA SLC_2011_WorkFlow]&lt;br /&gt;
* MIT 2010 Summer [http://wiki.na-mic.org/Wiki/index.php/Summer_project_week_2010_Workflows_SOA MIT_2010_WorkFlow]&lt;br /&gt;
&lt;br /&gt;
= Research Plan =&lt;br /&gt;
*Create a stand-alone SPINE desktop agent with fully functional data exchange and communication mechanisms towards 3D Slicer and XNAT.&lt;br /&gt;
*Develop Service Oriented Architecture (SOA) SPINE System that will include 3D Slicer image processing modules deployed as web services as well as a workflow management system to orchestrate interaction between 3D Slicer, XNAT, and 3-rd party tools.&lt;br /&gt;
*Implement two-way control and communications between 3D Slicer and SPINE modules.&lt;br /&gt;
*Adapt SPINE System for cluster and grid computing scenarios.&lt;br /&gt;
*Provide with workflow and 3D Slicer web service wrappers editing tools.&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:UseCaseScenarios| Use Case scenarios]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PETCTWorkflow| PETCTWorkflow]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:AgingStudySegmentation| AgingStudySegmentation]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:TwoTensorTractography| TwoTensorTractography]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:LongitudinalMultimodalityRegistrationSuite| LongitudinalMultimodalityRegistrationSuite]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:MigrationJavaClients2QT| MigrationJavaClients2QT]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PediatricMSSegmentation| PediatricMSSegmentation]]&lt;br /&gt;
*[[DBP3:Utah:RegSegPipeline| MRI-based study and treatment of atrial fibrillation]]&lt;br /&gt;
&lt;br /&gt;
= Application Server / Workflow Engine Downloads =&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:WFEngineDownloads| Download Links]]&lt;br /&gt;
&lt;br /&gt;
=Key Personnel=&lt;br /&gt;
* Charles Gutmann, MD., 4%,  9-17-2009 through 9-16-2011&lt;br /&gt;
* Alexander Zaitsev, Ph.D., 75%, 9-17-2009 through 9-16-2011 &lt;br /&gt;
&lt;br /&gt;
=Annual Progress Statements =&lt;br /&gt;
'''2010-11''' &amp;lt;br&amp;gt;&lt;br /&gt;
The  April 2011 – March 2011 period was devoted on developing portable workflow solutions that can be deployed on end-users' workstations or notebooks with minimal or no system administration activities. This is in contrast to the server-side deployment. The following scenarios had been deployed and used for actual projects that require the following types of workflows: PET/CT registration and computation of biomarker driven brain physiological activities, Brain MRI Images segmentation,  MRI and MRI Angiography images pre-processing for cardiac ablation outcome estimation. Some  workflows (like EM Segmentation) had been utilizing various scenarios, some research projects  (like evaluation of chemotherapy outcome) require two types of workflows to assess physiological and structural changes. Starting from the 4th Quarter of 2011, the migration project had been emerged in order to embed Workflow GUIs into newly developed Slicer4 Suite. The existing rich client Java GUI applications are being re-written as C++/QT Sliceletts units, new modules (such as cardiac ablation project support) are had been written from scratch. The latter are being deployed from the Slicer4 GUI and act at a liaison between Slicer4 and Application Server containing  workflow and Slicer modules deployed as services. The feedback from the end users indicates that Workflow approach for the complex processing improves productivity, aids to the processing standardization and contributes to the overall experience using 3D Slicer&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
=Quarterly Progress=&lt;br /&gt;
&lt;br /&gt;
* '''2d Qtr, 2011''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study: Second release deployed. &lt;br /&gt;
*** End-users completed the first Project and currently analyzing SUV values and clinical data&lt;br /&gt;
*** New features added: Human Brain Hemispheres segmentation, Scull-stripping for total SUV counts calculation, Flexibility of custom designed label look-up table usage (users can define ROI notation according to the Project needs)&lt;br /&gt;
&lt;br /&gt;
** Left Atrium Ablation Assessment (CARMA Project)&lt;br /&gt;
*** Completed workflow pipeline for automated pre-processing and manual intervention&lt;br /&gt;
*** Developed front-end GUI for the CARMA Project support in Slicer4.&lt;br /&gt;
*** Run the workflow with the end users during NAMIC Project Week&lt;br /&gt;
*** Evaluated feasibility of left atrium wall and post-ablation scar segmentation using Robust Statistical Segmentation (RSS). Identified necessary processing controls with RSS module designers&lt;br /&gt;
&lt;br /&gt;
** Multiple Sclerosis CLIMB Study&lt;br /&gt;
*** Reprocessing for lesion segmentation&lt;br /&gt;
*** Developed Web-based (Java EE 6) application for submitting cases to the workflows for EM Segmentation of MPRAGE and registration to PD/T2/FLAIR images (60% completion)&lt;br /&gt;
&lt;br /&gt;
** EM Segmentation: &lt;br /&gt;
*** Upgraded EM Segmentation services to Slicer 3.6.4&lt;br /&gt;
*** Added brain hemispheres segmentation module to the workflows (used for PET/CT Longitudinal study)&lt;br /&gt;
*** Work with EM Segmenter module developers on building pipelines for white matter lesion segmentation (work in progress)&lt;br /&gt;
&lt;br /&gt;
** Plans for the 3rd quarter&lt;br /&gt;
*** Migrate CARMA Project workflow to end-users&lt;br /&gt;
*** Packaging of Slicer4 Workflow modules and Slicer4 custom build distribution &lt;br /&gt;
*** Completion of Web-base segmentation and registration suite&lt;br /&gt;
*** Users and Developers Documentation&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* NAMIC Annual Progress Slides (April 2010 - March 2011):&lt;br /&gt;
&lt;br /&gt;
* '''1st Qtr, 2011''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study: Second release is under testing by end-users. &lt;br /&gt;
*** Added MRI registration to aid ROI drawing on PET scans&lt;br /&gt;
*** Improved SUV results reporting and added flexibility to update ROI lookup table&lt;br /&gt;
*** Automated EM Segmentation of MRI images for computing SUVs for white matter, CSF, and whole brain (80% completion)&lt;br /&gt;
*** Integration with SPECTRE scull stripping module (70% completion) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** EM Segmentation: Automated WF Pipelines are created &amp;lt;br&amp;gt;&lt;br /&gt;
*** Flexible atlas selection (Pediatric, etc) feature added&lt;br /&gt;
*** Workflows implemented for EM Segmenter 3.6.2 and 3.6.3 (1st Qtr 2011 release)&lt;br /&gt;
&lt;br /&gt;
** Cardiac ablation results follow-up: Workflow for registration and ROI selection of cardiac MRI and MR Angiography &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Wrokflow and Web Services for prospective DTI tractography modules (currently written as Matlab modules at PNL) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Web Services for SPECTRE Scull stripping module&lt;br /&gt;
*** Accuracy and performance tuning&lt;br /&gt;
*** 50% completion&lt;br /&gt;
&lt;br /&gt;
** Migration Front End GUI to Slicer4/QT:&lt;br /&gt;
*** EM Segmentation&lt;br /&gt;
*** Cardiac Ablation Study&lt;br /&gt;
&lt;br /&gt;
** DICOM Uploader and Desktop Browser for XNat Image repository (alpha version - tested for MGH MS Center studies, proposed to use with MI2B2 Clients and Services)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''4th Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study and EM Segmentation for Aging Study are deployed at end-user sites and actively used for research. &lt;br /&gt;
** Adopted EM Segmentation preprocessing pipeline for HIV Study: high resolution SPGR images, integration with FreeSurfer brainmask extraction outputs; integration of Slicer SPECTRE module for brainmask extraction is in progress.&lt;br /&gt;
** The following post-release upgrades had been implemented based on end-user feedback: Application Server basic controls are performed from Rich Client GUI as alternative to traditional IT administration activities. The controls are implemented on point-and-click bases and include web services and workflow application deployment and upgrades, application server start and stop as well as warning end user when the server is not accepting request.&lt;br /&gt;
** Added DICOM downloads and results uploads of PET/CT pipelines from and to XNat Repository&lt;br /&gt;
** Created Services and Workflow for Matlab Prototypes modules. Case Study: tractography for DTI images&lt;br /&gt;
** Extended XNAT integration services:&lt;br /&gt;
*** Browsing capabilities of XNat data repository from the Workflow Applications&lt;br /&gt;
*** Improved DICOM upload and download performance&lt;br /&gt;
*** Added Metadata organizing services for uploaded DICOM images: header data extraction, image snapshots creation. &lt;br /&gt;
** Started project for Rich Client GUI migration from Java desktop application to build into SLicer4 QT modules. This affects mostly front-end GUI and has the following approaches: distribution with the Slicer4, end-user will select desired workflow application from Slicer4 menu while QT-written modules provide with the same functionality as Java Rich Clients. Case Study for the Migration process: registration suite for longitudinal studies that include multi-modality images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* '''3d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Concentrated on building downloadable workflow applications that could run both in desktop (new) and server environment, and that require minimum IT administrative resources. The desktop deployment is in compliance with Slicer3 general deployment concept.&lt;br /&gt;
*** The following use case scenario had been chosen: PET/CT image processing for longitudinal studies, EM Segmentation for longitudinal Aging Study.&lt;br /&gt;
** Released workflow application for PET/CT image processing for longitudinal studies. Provided end users with training and documentation.&lt;br /&gt;
*** The PET/CT processing workflow was designed to be a general application used whenever both structural patterns and metabolic activities are within the research scope. &lt;br /&gt;
*** The desktop version is tuned to use minimal computer resources, so the automates processing instances do not interfere with human activities. Automated activities may include, for example, registration and PET scan's standard uptake values computing, and manual human activities may include image cropping, quality control, and labeling voxels of interest.&lt;br /&gt;
** Core services and EM Segmentation preprocessing workflow was build for retrospective Aging Study. Tuned the Slicer3 webservices for processing low grade images acquired in mid 90s. Entire workflow is implemented with Slicer3 only modules and can be deployed locally and on the servers. Usage of Service Oriented Architecture (SOA) as a core technological approach allowed reusing most of the web services that had been build for PET/CT project. &lt;br /&gt;
** Continued embedding Slicer3 application and modules into previously released processing pipelines: replaced MIPAV with Slicer3 GUI for lesion assessment step in the multi-center Pediatric MS Cohort image processing &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''2d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Completed Social Cognition Workflow Implementation. This includes EM Segmetnation pre- and post-processing pipelines, data tracking, and integration with 3d party image processing utilities, as well as processing results acquired manually with Slicer GUI.  &lt;br /&gt;
** Multi-modality image registration and ROI selection/alignment workflow for longitudinal studies. &lt;br /&gt;
*** Use case: PET/CT image processing for longitudinal studies. &lt;br /&gt;
*** Build portable library of Slicer modules as web services and workflow that are deployed and run on a end-users' worksatations without utilization of SPL and other servers. The web services include novel Slicer3 modules, such as BRAINSFit and BRAINSResamle &lt;br /&gt;
*** Started working with Slicer3 developers on Slicer 3.8 GUI wizard to communicate with workflow instances.&lt;br /&gt;
** Participated at NA-MIC Summer 2010 Project Week: [[Summer_project_week_2010_Workflows_SOA]]&lt;br /&gt;
&lt;br /&gt;
=Progress=&lt;br /&gt;
* August 1, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT&lt;br /&gt;
* Follow-up with end users with new Study setup&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
CARMA Project&lt;br /&gt;
* Documentation (Work in progress)&lt;br /&gt;
* Plans for next week: custom packaging (Mac Snow Leopard 64 bit), building extension, documentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation&lt;br /&gt;
* Stress-test of online segmentation requests suite for  [http://www.slicer.org/slicerWiki/index.php/EMSegmenter-Tasks#Additional_Use_Cases CLIMB Study](for BWH MS Center)&lt;br /&gt;
* Reason for building online suite: the Group is Using mostly MAC OS Tiger machines for legacy reasnos, the most recent Slicer3 builds as well as QT don't work on those machines (QT4.x runtime could not be installed).&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* July 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA Project&lt;br /&gt;
* Documentation (Work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation&lt;br /&gt;
* Work on alpha-release of online submission of segmentation requests (for BWH MS Center)&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* July 22, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
Vacation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* July 8, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
3D Slicer in General and CARMA Project&lt;br /&gt;
* Presentation and life demo at Cardiology Research Center (Moscow, Russia) [[File:RussianCardiologyCenterCARMA2011.ppt]]&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* July 1, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA V1.0&lt;br /&gt;
* Migration to new QT building environment (Mac 10 Snow Leopard). &lt;br /&gt;
* Building custom package. Issues: new features (not only WF related) are not shown on the menu of the resulting application&lt;br /&gt;
* Comparing preprocessing workflow results with published in literature data (our module produces better alignment)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*June 24, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
Project Week:&lt;br /&gt;
* Testing RSS module for left atrial wall scar segmentation&lt;br /&gt;
* Testing EM Segmenter for lesion detection on PD (requested by end-users) and FLAIR images&lt;br /&gt;
&lt;br /&gt;
EM Segmentation &lt;br /&gt;
* Web-based segmentation and registration module for MS Center. Goal: facilitate 3D SLicer modules for the cases that could not be processed with in-house build DTS+ algorithm&lt;br /&gt;
* Pipeline: Segment MPGR or T1 (user's choice), Register MPGR to PD/T2, Resample Segmentation Map to PD/T2. Completion: 60-70%.&lt;br /&gt;
* The rest will be done manually or via lesion segmentation with EM Segmenter.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* June 17, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
Preparation for Project Week&lt;br /&gt;
&lt;br /&gt;
* June 10, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
CARMA V.1.0&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code completed and tested&lt;br /&gt;
* Packaging as extension is pending (Subject for Summer 2011 Project week)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Debugging consolidation results issue(SUVs for manual and automated segmentation) &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* June 3, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Deployed on end-user's machine&lt;br /&gt;
* TODO next week: fix SUV results consolidation issue (when MRI segmented ROI got SUV computed for some subjects, only those subjects' SUVs are being added into consolidated report. &amp;quot;Raw&amp;quot; SUV values per subject are generated as expected)  &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 27, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Ready for deployment. New Features: hemispheres EM Segmentation, automated ICC/brainmask extraction using EM Segmenter, fixed controls for MRI conversion and registration&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 20, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General / PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Hemispheres EM Segmentation - adjusted for required label lookup table&lt;br /&gt;
* Use cases added for EM Segmenter General Project: http://www.slicer.org/slicerWiki/index.php/EMSegmenter-Tasks#EMSegmenter_use_cases&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SPECTRE Scull Stripping&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* The new version to be tested on coming week (After PETCT MRI processing migrated to Hemispheres scenario )&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* May 13, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General / PETCT V1.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Hemispheres EM Segmentation - technically works with labal values hardcoded in Slicer EM Segmenter - need to add manual label value edition step&lt;br /&gt;
* PETCT WF Cut for Java GUI (Pending Hemispheres label update completion). Next release will be in QT4.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* May 6, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (QA of EM Segmenter module, work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* April 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Open Discussion for Packaging WF QT Modules as Slicer4 extensions (waiting for SOPs)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review supported projects http://wiki.na-mic.org/Wiki/index.php/File:SlicerWF_EMSegmentProjectsReview.zip &lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (required by Study)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Slicer Modules General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Standardizing Crop Volumes Output (with A. Fedorov's module). Review for required updates of existing product (PET/CT, CARMA)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Open Discussion for Packaging WF QT Modules as Slicer4 extensions (waiting for SOPs)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review supported projects http://wiki.na-mic.org/Wiki/index.php/File:SlicerWF_EMSegmentProjectsReview.zip &lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (required by Study)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Slicer Modules General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Standardizing Crop Volumes Output (with A. Fedorov's module)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 22, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Beta release ready. Demo Location: http://cni29.bwh.harvard.edu/SlicerWFDemo/index.php&lt;br /&gt;
* TODO: Tutorial. Original inputs copy/renaming&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 15, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Adding App server auto-config features&lt;br /&gt;
* Finalizing the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 08, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Second release beta build tested on cosutmer side &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review registration quality (with Dr. Meier). Angiography images' Resampling tuned. &lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 01, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the second release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
XNat Integration&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* (Java) GUI for Project Browsing and DICOM Series Upload. Post-upload DICOM processing tested and debugged&amp;lt;br&amp;gt;&lt;br /&gt;
* Ready for integration with mi2b2 client.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Migrated to Latest Slicer 3.6.3 stable release: only the Input scene had to be updated, the API remained the same&lt;br /&gt;
* Tested EM Segmenter with CMTK4Slicer extension - processing takes to much time on Linux_64bit machine, rolled back to BRAINSFit registration. When used on Mac OS X build, the Slicer could not start (bug report 1126).&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SPECTRE Scull Stripping:&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Testes for various use cases: the module is extremely sensitive to T1 MRI quality (does not work for most MRIs from PET/CT project&lt;br /&gt;
* TODO next week: check for FLAIR images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Slicer4 QT GUI and Cropping activity in progress.&amp;lt;br&amp;gt;&lt;br /&gt;
* Tried direct MRA to MRA registration option: resampling with LMRI registration transforms works better.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Extra VOI labels revised&lt;br /&gt;
* Debugging of SUV results' renormalization step&lt;br /&gt;
* TODO: ICC extraction / whole brain total uptake computing; EM Segmentation for R_WM, L_WM SUV computing and BPH estimation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SCULL STRIPPING/SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Installed and tested CLI option on Linux_64bit platform&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Workflow interruption before BSPline registraton: BPEL Module completed. Slicer4 QT GUI and Cropping activity in prorgess.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Implemented and Tested with end-users proposed changes: denormalization of SUV results, adding more VOI labels, added FLAIR MRI in addition to T1s for VOI drawing&lt;br /&gt;
* Tested manual ICC extraction using PET scans: works satisfactory with island removal and cropping followed by threshold level labeling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4&lt;br /&gt;
* Change proposed: interrupt workflow after affine registration and have user crop the VOI. This is to prevent excessive deformations for BSpline registration and resampling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4. User has option to choose the atlas that fits better for the given subject (NOTE: hardcoding must be rewritten for atlas linking)&lt;br /&gt;
* PETCT test - the problem is that T1s are low resolution and with contrast. Proposed using T1s without contrast&lt;br /&gt;
* PETCT change request: users wants to compute SUV for entire ICC. Had demo how to segment brainmask/ICC using PET scan. The derived brainmask label can be used for SUV computation.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - cmpleted&lt;br /&gt;
* Sample cases run - excessive deformation after BSpline registration hase&lt;br /&gt;
* Next week plan - pull tuning controls to front-end of pipeline API, start working of QT module for CARMA registration&lt;br /&gt;
* May consider other than BRAINSFit registration modules&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Design plan for change request: more VOI labels, add FLAIR in addition to T1 for VOI drawing, T1s segmentation&lt;br /&gt;
* Tested segmentation for sample cases - artifacts from poor quality MRIs lead to exclusion of parts of ICC from segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Completed troubleshooting of EMSegmenter module calling from Java (need TCL libs to be pulled from Slicer environment)&lt;br /&gt;
* Tested EMSegmenter autoruns for HIV and Pediatric MS patiens. Work as expected, subject to improvement of PED MS case segmentation by building better skull/neck/air atalses&lt;br /&gt;
* Suggested usage of two subsets of atalases: with and without neck. The Subject MRIs have to be cropped accordingly or best fit atlas has to be selected&lt;br /&gt;
* Made no-neck cropped atlas collection for default EMSegmenter scenario&lt;br /&gt;
* Tested with PET/CT study MRI cases - see above &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - in progress&lt;br /&gt;
* Next week goal - have back end processing ready&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Longitudinal Study&lt;br /&gt;
* Added MRI registration to the pipeline&lt;br /&gt;
* Troubleshooting of complex XML schema issues on Linux machines (some modules working on MAC do not work on Linux). As a workaround - did not include MRI convert and register part into base BPEL module. Used separate services (transparent for end-user)&lt;br /&gt;
* TODO next week for change request completion: explicit pixel type casting for MRI in BRAINSFit, VOI MRML scene update (currently MRI added on top of schema)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* February 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipeline for Pediatric MRI. Same scenario as for HIV Project, icbm pediatric atlases (Completed, verified)&lt;br /&gt;
* Collected NIH healthy brain development atlases: various age ranges from 4.5 to 18 yo. Converted to Slicer readable format &lt;br /&gt;
* Work on web services for the new automated EM Segmenter module (release Nov 10 - current). Verified task completion both for adult and pediatric images. Discussed tuning parameters for work load balance on workstations.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Started working on MRI registration to the reference CT scans. &lt;br /&gt;
* Design specs for optional White Matter segmentation for SUV computing.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* February 4, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipelines for Pediatric MRI (in progress)&lt;br /&gt;
* Adapting Pediatric T1 atlases for &amp;quot;Human Brain&amp;quot; build-in EM Segmentation wizard (in progress)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 28, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Verifying EM Segmenter module for latest builds and HIV/PED MS Studies (report pending)&lt;br /&gt;
* Work with SPECTRE module developers with pediatric MRI brainmask extraction&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* January 21, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Compiling plan for WF FrontEnd GUI migration to Slicer4/QT Widgets&lt;br /&gt;
* Preparing for annual progress report&lt;br /&gt;
&lt;br /&gt;
* January 14, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI: Integrated into the Slicer4 as Slicelet (or thin Client)&lt;br /&gt;
* Participation at AHM-2011, discussing integration of SPECTRE module and updated approach to EM-Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA&lt;br /&gt;
&lt;br /&gt;
* January 7, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* HIV project workflow delivered. Major additions relate to user convenience: &lt;br /&gt;
- Project-specific parameter settings, importing T1s and brainmasks from FreeSurfer outputs with conversion to NIFTI, resampling brainmask to original scans and automatied subject addition.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Follow up with end user: need to add MRI scans, if available, addition and registration to CT in order to ease VOI drawings.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
 &lt;br /&gt;
* December 31, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Follow-up with user Experience for AGING Study Segmentation (Positive feedback)&lt;br /&gt;
* Target date for HIV project delivery - next week&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Self-training for QT widget development&amp;lt;br&amp;gt;&lt;br /&gt;
* Outlined Workflow Rich Clients migration strategy from Java to QT/Slicer4:&amp;lt;br&amp;gt;&lt;br /&gt;
** Use Java Stubs (similar to SPECTRE integration) or file binding for envocation of workflow pipelines. (See SOAP remark below)&lt;br /&gt;
** Direct Web Servisec calls must be wrapped into REST protocol. The reason: NON-commerchial QT kit does not include SOAP protocol for web servises.&lt;br /&gt;
** The GUI will be implemented as page widget or QT dialog GUI forms called from within Slicer4.&lt;br /&gt;
** Communications between Slicer4 and WF GUI will be set via child-parent and signal-slot relations&lt;br /&gt;
* Worked on a Prototype for Basic EM Segmentation QT widget (70% complete). Will work on integrtion with SLicer4 during the AHM-2010&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
XNAT Integration&lt;br /&gt;
* Debugged XNAT RESTFul API usage for uplaoding DICOM series followed by header data extraction and image snapshots creation&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Added compensation for failed atlas registration (subject for old poor quality pseudo-T1 images): blank probability maps are created in case of failure.&lt;br /&gt;
* Data preparation module for FreeSurfer data import near completion. Expected time for deployment at end-users workstations - first week of January&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Discussed strategy for EM Segmentation pipeline solutions collection (K. Pohl, R. Kikinis)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* RE-using the same core workflow as for 1-channel EM Segmentation of AGING STUDY cases&lt;br /&gt;
* Added data input preparation module: ICC label mask preparation and skull-stripping based on FreeSurfer brainmask output volume.&lt;br /&gt;
* Two-channel EM segmentation pipeline (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE / GENERAL Development &amp;lt;br&amp;gt;&lt;br /&gt;
* Worked on plans for migrating fro rich workflow Java clients to embedded workflow windows inside the Slicer.&amp;lt;br&amp;gt;&lt;br /&gt;
The embedded workflow management clients are to be implemented with QT/PyQT toolkits&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
INTEGRATION WITH XNAT:&amp;lt;br&amp;gt;&lt;br /&gt;
* Automated DICOM series upload with triggering DICOM headers parsing at XNat site (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress. &lt;br /&gt;
- Results upload to XNat (Completed) &amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat based on user's input (Project + Subject + PET or CT session / scan) (Completed)&amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat - perfomance boosting solution for downloads found , web services services are created, relinking for the client side in progress &amp;lt;br&amp;gt;&lt;br /&gt;
- Xnat querying for subjects and automated subject addition into the workflow (In Progress) &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-segmentation module added for auto correction of segmentation results. Particularly - relabeling CSF voxels segmented as Air inside the intracranial cavity. This was requested by end-users after processing images with zero-signals in CSF voxels &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting automated dual-echo DICOM images conversion and split into two NRRD volumes&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT / EM Segmentation pipeline:&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting memory allocation issues for scull-stripping module SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
COPD Project:&amp;lt;br&amp;gt;&lt;br /&gt;
* Benchmark test for accelerated DICOM downloads from XNat (remoote XNat Central server): we can handle at least 6 cases (4 CT scans in each) per hour, which is compatible with current workload quotes on SPL cluster processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* December 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Deployed Version 1. &amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Test project chosen as a closest match to registration scenario: Pediatric MS Cases from MGH - requires periodic image preview for different &lt;br /&gt;
modalities taken from vaious time points. Label maps for VOIs resampling is also required.&lt;br /&gt;
&lt;br /&gt;
* November 26, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user. Version 1 is complete&amp;lt;br&amp;gt;&lt;br /&gt;
* Started working on integration with XNat&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on input data organizing modules&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 19, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user (70% done)&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Universal Registration Workflow for Longitudinal Studies - design specs in progress&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 12, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Minor tuning to EM Segmentation template as of users' feedback&lt;br /&gt;
* Users started using the workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed input data conversion from Genesis to Slicer native or NIFTI format. Our help may be needed in input data organizing.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Tuned application according to co-laborators (PNL) needs&amp;lt;br&amp;gt;&lt;br /&gt;
* The webservices and BPEL workflow application are tested ready to accept computation requests from PNL case tracking system &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Discussed Universal Registration Workflow for Longitudinal Studies&lt;br /&gt;
* Started the thread about possible cooperation with Children hospital's image processing pipelines and integration with Xnat &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 5, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Webservices and workflow pilot project created and deployed on Psychiatry Neuroimaging Laboratory subnet &amp;lt;br&amp;gt;&lt;br /&gt;
* The V.1.0 deployment is scheduled for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 29, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Most of functionality is completed. Some volume statistics post processing is pending&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL EM SEGMENTATION Pipeline: &amp;lt;br&amp;gt;&lt;br /&gt;
* The SPECTRE scull stripping module. Started integration into EMS workflow. Made some test runs from Slicer GUI&amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Identified as a candidate for Workflow Application&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 22, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* All back-end functionality are implemented&amp;lt;br&amp;gt;&lt;br /&gt;
* EM Segmentation scene usability is confirmed by end-user&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for next week: add Label Statistics computation for CSF/Brain/ICC &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 15, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* The latest (October) builds of Slicer 3.6.2 produced acceptable results. This was verified by the target users. The EM Segmentation will be performed on Slicer 3.6.2 or later&amp;lt;br&amp;gt;&lt;br /&gt;
* The new Web services had been created and added to the pipeline as optional processing steps: Biasfield correction (implement novel N2ITKBiasFieldCorrection module) and Volume's scalar datatype casting (as workaround for Biasfield correction module not preserving image scalar datatype - the bug is filed) &amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed the Front-End GUI design with target users. The design pattern is taken from the PETCT project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 8, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-deployment support. Tuned CT registration as of user's feedback.&lt;br /&gt;
* Adapting to the Single Slicer build: Slicer 3.6.2. Found label duplicates in the label lookup table - will ask user if it's tolerable. Waiting for the Slicer 3.6.2 build that contains all required modules. Rolling back label tag appending code for SUVs - the latest Slicer build appends the tags.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Resumed development. The priorities are set for usage of Slicer 3.6.2 - subject for EM Segmentation scene tuning. Continued coding for Scene creation for Slicer 2.8 - as a backup option for ongoing research project.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 1, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized V1.0 release based on end-user feedback: updates relate mostly to error proofing and SUV values representation&lt;br /&gt;
* Post-deployment support. Users pre-processed first set of patients &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* September 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* System deployed and tested at End Users' site.&amp;lt;br&amp;gt;Users are trained to perform all tasks required by the workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
* Got positive feedback with suggestions on Slicer Scenes' layouts improvement and PET scans' SUV (standard uptake values) results display&lt;br /&gt;
* Two distribution packages are assembled: Lunix and MAC OS versions. The difference in two packages is in specific Slicer3.6/3.7 builds - subject to Slicer Linux builds debugging.&amp;lt;br&amp;gt; As a workaround for Linux deployment - multiple Slicer builds are used to perform various tasks (registration, opening editing scenes in Slicer, SUV computing)&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for coming week - finalize V1.0 release based on end-user feedback&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Embedded SUV computations into the workflow (as system calls - will be translated into web service later)&amp;lt;br&amp;gt;&lt;br /&gt;
* Pre-release demo for end users.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Create and debug EM Segmenter scenes template for Slicer 3.6 and 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* September 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation - workflow pipeline and deployment verified&amp;lt;br&amp;gt;&lt;br /&gt;
* Tested EM Segmentation scenes within Slicer 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
* Started migration of EM Segmentation to Slicer 3.6. Discovered issues had been reported to EM Segmenter module designers &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* August 29 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation completed. Preprocessing Pipleine completed 80% (subject for input registration parameters tuning) &amp;lt;br&amp;gt;&lt;br /&gt;
* Most webservices (for registration and resampling steps) had been taken and re-used from PET/CT ROI/Longitudinal Study - showing the advantage of service-oriented software design and deployment.&lt;br /&gt;
* Continued on distribution and deployment of the service/workflow applications: on PET/CT and AGING STUDY projects.&lt;br /&gt;
&lt;br /&gt;
PEDIATRIC Multiple Sclerosis Cohort. Support of multi-center distributed processing project&amp;lt;br&amp;gt;&lt;br /&gt;
* Introduced Slicer 3.6 for the MS Lesion Assessment step performed at Mayo Clinic. Images are being transferred from image repository at BWH and automatically opened and arranged within Slicer GUI for reading.  This was replacement of Client GUI using MIPAV that stopped working on new computers at Mayo Clinic.&lt;br /&gt;
The images are being loaded via generated MRML Scenes same way as in PET/CT and AGING STUDY projects &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* August 22 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Preprocessing pipeline merge with SUV computations &amp;lt;br&amp;gt;&lt;br /&gt;
- QA for SUVs computation was performed by Wendy Plesniak for images with known uptake values. &amp;lt;br&amp;gt;&lt;br /&gt;
- Discovered that image cropping step (not related to automated registration pipeline and SUVs computing) smoothes the images by doing interpolation when used with default settings. Got suggestions from Steve Piper using Nearest-Neighbor interpolation (&amp;quot;no interpolation&amp;quot;) for a time being&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
- This is the new project candidate. Requested for the images with failed manual segmentation and/or segmentation with FreeSurfer. The EM Segmentation run showed most acceptable results on one of the problem images back in February &amp;lt;br&amp;gt;&lt;br /&gt;
- The workflow will be developed and deployed similar to PET/CT ROI Longitudinal study approach - all preprocessing steps will be done with Slicer modules, all runs will be performed on local end-user machines.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
 &lt;br /&gt;
&lt;br /&gt;
* August 15 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- First 5 cases with 3-4 time points preprocessed for SUVs computation&lt;br /&gt;
&lt;br /&gt;
* August 8 2010&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Testing of installation and operation at users' site (Performed by Wendy Plesniak)&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* July 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Delivered beta version of registration pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
- Prepared installation and user manuals &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* June 11, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Registration modules completed &amp;lt;br&amp;gt;&lt;br /&gt;
- Irregular cases registration problem solved (when whole body and brain only scans are mixed for a timepoint)&amp;lt;br&amp;gt;&lt;br /&gt;
- Live demo of case setup and registration workflow for end users. Real case with 4 timepoints used&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Coming week plans&amp;lt;br&amp;gt;&lt;br /&gt;
- Adjust workflow based on end users' feedback&amp;lt;br&amp;gt;&lt;br /&gt;
- Integration with SUVs computing for PET scans&amp;lt;br&amp;gt;&lt;br /&gt;
- GUI for workflows dispatching and data organizing&amp;lt;br&amp;gt;&lt;br /&gt;
- (TBD) Integration with 4D time series analysis Slicer module&amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
* May 28, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- Migration to the latest Slicer 3.6 release candidate &amp;lt;br&amp;gt;&lt;br /&gt;
- Added webservice for new registration module: BRAINSFit &amp;lt;br&amp;gt;&lt;br /&gt;
- Test runs for new patients with 4 timepoints' scans &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Plans for next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI &amp;lt;br&amp;gt;&lt;br /&gt;
- processing workflow demo for end user &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 21, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Pilot version of portable web services and automated workflow tested: &amp;lt;br&amp;gt;&lt;br /&gt;
Linux: workflow and visual review passed&amp;lt;br&amp;gt;&lt;br /&gt;
Stress test for 25 timepoints passed &amp;lt;br&amp;gt;&lt;br /&gt;
MAC OS: workflow passed, visual review failing when PET/CT images are loaded into GUI simultaneously (bug report submitted)&amp;lt;br&amp;gt;&lt;br /&gt;
Windows: need to adapt command line modules and workflow management system to sygwin environment&amp;lt;br&amp;gt;&lt;br /&gt;
Plans for next week: integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI&lt;br /&gt;
&lt;br /&gt;
* May 7, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Selected registration and resampling modules with more precise and stable outputs. &amp;lt;br&amp;gt;&lt;br /&gt;
Started building portable web services and automated workflow &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 30, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- manual walk through the processing steps: ROI cropping, registration/resampling, PET pharmaceutical DICOM data retention. &amp;lt;br&amp;gt;&lt;br /&gt;
- testing workflow and web services packages distribution to end-users' machines&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* April 23, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : testing various registration and re-sampling algorithms (work in progress)&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation: as of collaborators' request, run existing EM Segmentation workflow for older low resolution pseudo-T1 images. The EM Segmentation works for those images with manual sampling. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 16, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
  Social Cognition Study: started Cortical Thickness Measurement module build (bases on NA-MIC ARCTIC pipeline) &amp;lt;br&amp;gt;&lt;br /&gt;
  PET/CT ROI/Longitudinal Study Registration : Design specs, PET-to-CT images registration tests on training data. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 9, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. GUI update based on end-user experience.&amp;lt;br&amp;gt;&lt;br /&gt;
User request: automated label maps' volumes calculation (Currently possible from Slicer3 GUI)&amp;lt;br&amp;gt; &lt;br /&gt;
PET/CT ROI Project. Initial design specs discussion with end-users and co-developers&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure&lt;br /&gt;
Verification of segmentation workflow GUI: from registering new case to reviewing results&amp;lt;br&amp;gt;&lt;br /&gt;
Cross study test of segmentation workflow: MGH/MS Center data - success,  HIV Project data - some EM Segmentation scene tuning is needed &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*&lt;br /&gt;
* April 2, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. Segmentation workflow completed&amp;lt;br&amp;gt;&lt;br /&gt;
* Coming Week plans:&amp;lt;br&amp;gt;&lt;br /&gt;
- Document Segmentation Workflow. Follow up with end users &amp;lt;br&amp;gt;&lt;br /&gt;
- Start with Cortical Thickness and ROI-in-longitudinal studies workflows&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* March 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All essential processing and workflow interaction clients are ready.&amp;lt;br&amp;gt;&lt;br /&gt;
- Completed segmentation for 10 out of 50 patients. The remaining cases will be finalized upon manual lesion segmentation and QC verification of WM/GM/CSF and Deep GM segmentation's. &amp;lt;br&amp;gt;&lt;br /&gt;
- TODO next week: refine QC GUI and data tracking / progress monitoring schema. &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&amp;lt;br&amp;gt;&lt;br /&gt;
- New Slicer3 web services added: re-slicing with reference image volume, casting image scalar type &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
* March 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Segmentation maps Merging Services for GM/WM/CSF (Slicer EM Segemnter), Lesion (Slicer, Manual), and Deep GM (FreeSurfer)  &amp;lt;br&amp;gt;&lt;br /&gt;
- Deep GM segmentation pipeline adopted as optional service for Social Cognition Study (22 out of 50 cases processed) &amp;lt;br&amp;gt;&lt;br /&gt;
- (In progress) GUI client for Launching Segmentation results merging with optional Deep GM segmentation with FreeSurfer &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- Complete GUI Client for Segmentation result merging &amp;lt;br&amp;gt;&lt;br /&gt;
- Progress Monitoring services for entire Study processing: EM Segmenter Preprocessing, EM Segmentation, Lesion Segmentation (including human activities assignments), Deep GM segmentation, and results consolidation. &amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* March 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All 50 cases went through &amp;quot;basic&amp;quot; One-channel EM segmentation (GM/WM/CSF) &amp;lt;br&amp;gt;&lt;br /&gt;
- Basic pipeline start-up command line client created: user has two options - request brainmask extraction or provide with previously extracted brainmask for a given subject &amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison of GM/WN/CSF performed for Slicer EM Segmenter and FreeSurfer recon-all (used with default settings). &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmenter provides more accurate output &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmentation pipeline runs faster (40 minutes vs 12 hrs when no brainmask extraction requested) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO:&amp;lt;br&amp;gt;&lt;br /&gt;
- merging modules for automatic 1-channel EM segmentation and manual lesion segmentation &amp;lt;br&amp;gt;&lt;br /&gt;
- Emerge Cortical Thickness pipeline project: use NAC ARCTIC processing steps and modules &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Selected stable EM Segmentation scenario: White Matter, Gray Matter, and Cerebrospinal Fluid &amp;lt;br&amp;gt;&lt;br /&gt;
- First 16 cases are segmented for selected scenario. Nine more cases are preprocessed for EM Segmentation.&amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison to segmentation with FreeSurfer showed better accuracy for Slicer2 EMSegmenter &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure &amp;lt;br&amp;gt;&lt;br /&gt;
- Three prerpcocessed cases failed during volume ICC masking with in-house build utility. Evaluated switching to Slicer3 Mask and island removing modules.&amp;lt;br&amp;gt;&lt;br /&gt;
- Initial design specs discussion for cortical thickness measurement pipeline. ARCTIC pipeline selected. ARCTIC preprocessing steps signifficantly overlap with EM Segmentation preprocessing workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
  &lt;br /&gt;
* February 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: &amp;lt;br&amp;gt;&lt;br /&gt;
A) parameters tuning for EM Segmenter itself (work with EM Segmenter developer), template scenes creation &amp;lt;br&amp;gt;&lt;br /&gt;
B) update preprocessing pipeline - deep gray matter atlases included &amp;lt;br&amp;gt;&lt;br /&gt;
C) test and debug preprocesing pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
D) identified missing modules: atlas autocalibration for EM Segmentation scene, Island removal for ICC mask&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- Review currently deployed modules. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: reviewed firts seven subjects' outputs, added volume orientation module into pipeline (prevents ICBM atlas linear registration failures)&amp;lt;br&amp;gt;&lt;br /&gt;
- Fused ICC(brainmask) extraction module with EM Segmenter preprocessing. Three scenarious implemented: start with pre-extracted ICC mask (longitudinal studies case), run with ICC ectration, run with ICC extraction AND ICC correction before ICBM atlas preporcessing. &amp;lt;br&amp;gt;&lt;br /&gt;
- Completion of Human activities GUI (QC, ICC Correction) planned for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: Volume Orientation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: automated preprocessing pipeline for Slicer2 EM Segmenter test version deployed. Seven cases pre-processed.&lt;br /&gt;
- PET Quantitative measurements: Preliminary design specs discussion.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: BSplineRegistration (for non-linear registration), ResampleVolume2 (for atlases resampling based on image atlase templates registration). Local and Network runs are implemented, Cluster/GridWizard implementation pending.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Slicer EM Segmenter module: preprocessing design for Slicer2 EM Segmenter&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Adapting for Slicer2 EM Segmenter (mostly from pipelines and services for previous projects)&lt;br /&gt;
  -- Integration with FreeSurfer modules for bisafield correction, brainmask extraction, and linear registration of ICBM atlases&lt;br /&gt;
  -- Preprocessing updates for non-linear registration of ICBM atlases with Slicer2 (image re-orientation service designed)&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 29, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- EM Segmentaton pipeline: preprocessing results are being transferred to XNat (anonymized data, Central XNat) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Slicer EM Segmenter module: discussed agenda and scheduled a work meeting for Social Cognition Study image segmentation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Testing stage, 95% completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- SPL XNat server: verified data exchange via RESTfull web services.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 22, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Follow up with White Matter Lesion Segmenter and Scull Stripping Modules developers: Work in Progress&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Work in Progress, 60%+ completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Discussed SPINE image repository migration to XNat&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 15, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. &lt;br /&gt;
- Social Cognition Study: &lt;br /&gt;
Work-in-progress on intermediate (reconstruction) and results (resources) data storage at XNat.&lt;br /&gt;
&amp;lt;br&amp;gt;Reviewing and preparation more cases for EM Segmentor (Slicer 3.5) tuning.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* NA-MIC Project Week&lt;br /&gt;
Selecting candidate Slicer modules for other than Lesion EM Segmentation topics of Social Cognition study: Withe Matter Lesion Segmenter (UNC), Scull Stripping utility from UIOWA.&lt;br /&gt;
Reviewing issues of currently used Scull Stripping Slicer Extension and Slicer 3.5 EM Segmenter.&lt;br /&gt;
&amp;lt;br&amp;gt;XNat Data organizing training&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 1, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Preparation of Demo for NA-MIC work week: &lt;br /&gt;
- COPD Study. Added Remote pipepline start interface (represents real world scenario where Xnat repository, Processing modules and User are at different sites)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
- EM Segmentation. Added human activities steps to the workflow: ICC (brainmask) correction and EM Segmantation scena load per se.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 25, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Pilot workflow pipeline for EM Segmentation (all steps except user-activity step: ICC correction assignment and tracking)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 18, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Build and tested web services for EM Segmentation image preprocessing: DICOM-to-NRRD conversion, registration, skull stripping, image masking.&lt;br /&gt;
Started building workflow pipeline (subject to finish first version next week)&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Started Collecting Library of Slicer Build number vs. functional modules and extensions.&lt;br /&gt;
Plan for NAMIC project week: scheduled meetings for XNat data customization, Skull-stripping modules tuning, identified Social Cognition study cases that fail EM Segmentation processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 11, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Updating and verification of EM Segmentation Scenario&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Projects:ARRA:SlicerWF:UseCaseScenarios#Usecase_MS_lesion_Assessment&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Familiarizing with Slicer3.4/5 Modules required for implementation of EM Segmentation Scenario. Participation in debugging and/or usage tuning of Dicom Conversion, Registration, Skull Stripping, Masking, and Image Casting modules. &lt;br /&gt;
&lt;br /&gt;
* December 4, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Slicer3.4's EM Segmentation and Visual QC as part of image processing pipeline for Social Cognition Study for MS Patients.&lt;br /&gt;
Project emerged. EM Segmentation template creation debugged.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
Emphysema Measurements (COPD Study) - workflow stability and scalability test.&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 27, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Emphysema Measurements (COPD Study).&lt;br /&gt;
Added compensation for long running calculations and time-outs to the main computing pipeline.&lt;br /&gt;
Visual QC (work in progress)&lt;br /&gt;
** Infrastructure&lt;br /&gt;
XNat data structure customization, metadata storage, results consolidation: new feature request list creation (work in progress)&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 13, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
*** Pilot system for whole processing cycle for Emphysema Measurements (COPD Study) including the following:&lt;br /&gt;
Web query for CT session file list download&lt;br /&gt;
Pilot user interface for submitting the file list and starting processing pipeline&lt;br /&gt;
Notification about processing steps and failures&lt;br /&gt;
Upload results to XNat repository (at this stage results are uploaded into same folder where original scans are(*))&lt;br /&gt;
*** Immediate Plans&lt;br /&gt;
Complete Visual QC module&lt;br /&gt;
Design and implement meta-data transfer to XNat (including processing details and MRML files for loading images into the 3D Slicer)&lt;br /&gt;
&lt;br /&gt;
(*)Customization of results storage&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 6, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Tuned and debugged multiple subjects processing for: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat.&lt;br /&gt;
***Started working on quality control embedding into the above scenario. Plan to complete and video-record demo next week.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***Published general Product Integration scenario flow chart to collaborators' community. Discussion is open and in progress&lt;br /&gt;
&lt;br /&gt;
* October 30, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Piloted and tested the sequence: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat(1).&lt;br /&gt;
***Performance test of overall cycle: data transfer from remote serve is a bottleneck as expected&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data browsing features reviewed.&lt;br /&gt;
(1) Not automated yet&lt;br /&gt;
* October 23, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Defined COPD processing scenario with interoperability between Xnat, 3D Slicer Command Modules, Workflow, and Gridwizard Enterprise.&lt;br /&gt;
***Pilot version of Emphysema Measurements workflow pipeline deployed.&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data transfer features reviewed. Use account at XNat Central during learning curve.&lt;br /&gt;
***Feasibility test of 3D Slicer fiducials module for ROI highlights during QC and manual image processing activities. &lt;br /&gt;
* October 16, 2009&lt;br /&gt;
**Lung CT Scans Processing. Pilot project emerged. GenerateEmphysemaMeasurements module deployed as a webservice that submits jobs to computational cluster.&lt;br /&gt;
**EM Segmentation. Familiarized with GUI steps. Started working on automation steps outlining&lt;br /&gt;
**3D Slicer and XNat interaction. Got an overview from Wendy Plesniak.&lt;br /&gt;
* October 1 - 7, 2009&lt;br /&gt;
**Selected two first priority Projects: EM Segmentation of brain MRI images; Lung CT Scans Processing (COPD Study)&lt;br /&gt;
**Got initial outline of user requirements and design specs&lt;/div&gt;</summary>
		<author><name>Azaitsev</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=70190</id>
		<title>Projects:ARRA:SlicerWF</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=70190"/>
		<updated>2011-08-06T20:20:27Z</updated>

		<summary type="html">&lt;p&gt;Azaitsev: /* Progress */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Projects:ARRASuplements|Back to Slicer ARRA home page]]&lt;br /&gt;
= Aim =&lt;br /&gt;
Supplement 3D Slicer and Extensible Neuroimaging Archive Toolkit (XNAT) with workflow management system. Provide integration and interoperability between 3D Slicer, XNAT Services and 3-rd party image processing applications and high performance computing systems. Implement it as within currently developed Structural Planning and Implementation in Neurological Exploration (SPINE) System.&lt;br /&gt;
&lt;br /&gt;
= SPINE Project Documentation =&lt;br /&gt;
[http://cni.bwh.harvard.edu/projects/spine/index.html SPINE Docs]&lt;br /&gt;
&lt;br /&gt;
= Presentations =&lt;br /&gt;
* Segmentation Workflow. PECS University Social Cognition Study.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:SlicerWF_NAC_PECS_Workflow.pdf]]&lt;br /&gt;
* EAB10_ARRA Annual Progress Report Slides.&amp;lt;br&amp;gt;&lt;br /&gt;
[[media:EAB10_ARRA_WF_2011_Zaitsev.ppt | Service Oriented Solutions for 3D Slicer. EAB10_ARRA_WF_2011. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:EAB10_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:NAMIC_ARRA_WF_2011_Zaitsev.ppt  | NAMIC Annual Report 04/2010-03/2011. NAMIC_ARRA_WF_2011_Zaitsev. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:NAMIC_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:Slicer_WF_Slicer4CARMAWorkflow.ppt  | CARMA Workflow. Cardiac Ablation Followup. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:Slicer_WF_Slicer4CARMAWorkflow.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* CARMA Project Beta release Demo Location: http://cni29.bwh.harvard.edu/SlicerWFDemo/index.php&lt;br /&gt;
&lt;br /&gt;
* Segmentation Workflows: Screenshots, scans' and study description : [[File:SlicerWF_EMSegmentProjectsReview.zip]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
= All Hands Meeting Pages =&lt;br /&gt;
* Salt Lake City 2011 Winter [http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA SLC_2011_WorkFlow]&lt;br /&gt;
* MIT 2010 Summer [http://wiki.na-mic.org/Wiki/index.php/Summer_project_week_2010_Workflows_SOA MIT_2010_WorkFlow]&lt;br /&gt;
&lt;br /&gt;
= Research Plan =&lt;br /&gt;
*Create a stand-alone SPINE desktop agent with fully functional data exchange and communication mechanisms towards 3D Slicer and XNAT.&lt;br /&gt;
*Develop Service Oriented Architecture (SOA) SPINE System that will include 3D Slicer image processing modules deployed as web services as well as a workflow management system to orchestrate interaction between 3D Slicer, XNAT, and 3-rd party tools.&lt;br /&gt;
*Implement two-way control and communications between 3D Slicer and SPINE modules.&lt;br /&gt;
*Adapt SPINE System for cluster and grid computing scenarios.&lt;br /&gt;
*Provide with workflow and 3D Slicer web service wrappers editing tools.&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:UseCaseScenarios| Use Case scenarios]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PETCTWorkflow| PETCTWorkflow]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:AgingStudySegmentation| AgingStudySegmentation]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:TwoTensorTractography| TwoTensorTractography]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:LongitudinalMultimodalityRegistrationSuite| LongitudinalMultimodalityRegistrationSuite]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:MigrationJavaClients2QT| MigrationJavaClients2QT]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PediatricMSSegmentation| PediatricMSSegmentation]]&lt;br /&gt;
*[[DBP3:Utah:RegSegPipeline| MRI-based study and treatment of atrial fibrillation]]&lt;br /&gt;
&lt;br /&gt;
= Application Server / Workflow Engine Downloads =&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:WFEngineDownloads| Download Links]]&lt;br /&gt;
&lt;br /&gt;
=Key Personnel=&lt;br /&gt;
* Charles Gutmann, MD., 4%,  9-17-2009 through 9-16-2011&lt;br /&gt;
* Alexander Zaitsev, Ph.D., 75%, 9-17-2009 through 9-16-2011 &lt;br /&gt;
&lt;br /&gt;
=Annual Progress Statements =&lt;br /&gt;
'''2010-11''' &amp;lt;br&amp;gt;&lt;br /&gt;
The  April 2011 – March 2011 period was devoted on developing portable workflow solutions that can be deployed on end-users' workstations or notebooks with minimal or no system administration activities. This is in contrast to the server-side deployment. The following scenarios had been deployed and used for actual projects that require the following types of workflows: PET/CT registration and computation of biomarker driven brain physiological activities, Brain MRI Images segmentation,  MRI and MRI Angiography images pre-processing for cardiac ablation outcome estimation. Some  workflows (like EM Segmentation) had been utilizing various scenarios, some research projects  (like evaluation of chemotherapy outcome) require two types of workflows to assess physiological and structural changes. Starting from the 4th Quarter of 2011, the migration project had been emerged in order to embed Workflow GUIs into newly developed Slicer4 Suite. The existing rich client Java GUI applications are being re-written as C++/QT Sliceletts units, new modules (such as cardiac ablation project support) are had been written from scratch. The latter are being deployed from the Slicer4 GUI and act at a liaison between Slicer4 and Application Server containing  workflow and Slicer modules deployed as services. The feedback from the end users indicates that Workflow approach for the complex processing improves productivity, aids to the processing standardization and contributes to the overall experience using 3D Slicer&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
=Quarterly Progress=&lt;br /&gt;
&lt;br /&gt;
* '''2d Qtr, 2011''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study: Second release deployed. &lt;br /&gt;
*** End-users completed the first Project and currently analyzing SUV values and clinical data&lt;br /&gt;
*** New features added: Human Brain Hemispheres segmentation, Scull-stripping for total SUV counts calculation, Flexibility of custom designed label look-up table usage (users can define ROI notation according to the Project needs)&lt;br /&gt;
&lt;br /&gt;
** Left Atrium Ablation Assessment (CARMA Project)&lt;br /&gt;
*** Completed workflow pipeline for automated pre-processing and manual intervention&lt;br /&gt;
*** Developed front-end GUI for the CARMA Project support in Slicer4.&lt;br /&gt;
*** Run the workflow with the end users during NAMIC Project Week&lt;br /&gt;
*** Evaluated feasibility of left atrium wall and post-ablation scar segmentation using Robust Statistical Segmentation (RSS). Identified necessary processing controls with RSS module designers&lt;br /&gt;
&lt;br /&gt;
** Multiple Sclerosis CLIMB Study&lt;br /&gt;
*** Reprocessing for lesion segmentation&lt;br /&gt;
*** Developed Web-based (Java EE 6) application for submitting cases to the workflows for EM Segmentation of MPRAGE and registration to PD/T2/FLAIR images (60% completion)&lt;br /&gt;
&lt;br /&gt;
** EM Segmentation: &lt;br /&gt;
*** Upgraded EM Segmentation services to Slicer 3.6.4&lt;br /&gt;
*** Added brain hemispheres segmentation module to the workflows (used for PET/CT Longitudinal study)&lt;br /&gt;
*** Work with EM Segmenter module developers on building pipelines for white matter lesion segmentation (work in progress)&lt;br /&gt;
&lt;br /&gt;
** Plans for the 3rd quarter&lt;br /&gt;
*** Migrate CARMA Project workflow to end-users&lt;br /&gt;
*** Packaging of Slicer4 Workflow modules and Slicer4 custom build distribution &lt;br /&gt;
*** Completion of Web-base segmentation and registration suite&lt;br /&gt;
*** Users and Developers Documentation&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* NAMIC Annual Progress Slides (April 2010 - March 2011):&lt;br /&gt;
&lt;br /&gt;
* '''1st Qtr, 2011''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study: Second release is under testing by end-users. &lt;br /&gt;
*** Added MRI registration to aid ROI drawing on PET scans&lt;br /&gt;
*** Improved SUV results reporting and added flexibility to update ROI lookup table&lt;br /&gt;
*** Automated EM Segmentation of MRI images for computing SUVs for white matter, CSF, and whole brain (80% completion)&lt;br /&gt;
*** Integration with SPECTRE scull stripping module (70% completion) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** EM Segmentation: Automated WF Pipelines are created &amp;lt;br&amp;gt;&lt;br /&gt;
*** Flexible atlas selection (Pediatric, etc) feature added&lt;br /&gt;
*** Workflows implemented for EM Segmenter 3.6.2 and 3.6.3 (1st Qtr 2011 release)&lt;br /&gt;
&lt;br /&gt;
** Cardiac ablation results follow-up: Workflow for registration and ROI selection of cardiac MRI and MR Angiography &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Wrokflow and Web Services for prospective DTI tractography modules (currently written as Matlab modules at PNL) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Web Services for SPECTRE Scull stripping module&lt;br /&gt;
*** Accuracy and performance tuning&lt;br /&gt;
*** 50% completion&lt;br /&gt;
&lt;br /&gt;
** Migration Front End GUI to Slicer4/QT:&lt;br /&gt;
*** EM Segmentation&lt;br /&gt;
*** Cardiac Ablation Study&lt;br /&gt;
&lt;br /&gt;
** DICOM Uploader and Desktop Browser for XNat Image repository (alpha version - tested for MGH MS Center studies, proposed to use with MI2B2 Clients and Services)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''4th Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study and EM Segmentation for Aging Study are deployed at end-user sites and actively used for research. &lt;br /&gt;
** Adopted EM Segmentation preprocessing pipeline for HIV Study: high resolution SPGR images, integration with FreeSurfer brainmask extraction outputs; integration of Slicer SPECTRE module for brainmask extraction is in progress.&lt;br /&gt;
** The following post-release upgrades had been implemented based on end-user feedback: Application Server basic controls are performed from Rich Client GUI as alternative to traditional IT administration activities. The controls are implemented on point-and-click bases and include web services and workflow application deployment and upgrades, application server start and stop as well as warning end user when the server is not accepting request.&lt;br /&gt;
** Added DICOM downloads and results uploads of PET/CT pipelines from and to XNat Repository&lt;br /&gt;
** Created Services and Workflow for Matlab Prototypes modules. Case Study: tractography for DTI images&lt;br /&gt;
** Extended XNAT integration services:&lt;br /&gt;
*** Browsing capabilities of XNat data repository from the Workflow Applications&lt;br /&gt;
*** Improved DICOM upload and download performance&lt;br /&gt;
*** Added Metadata organizing services for uploaded DICOM images: header data extraction, image snapshots creation. &lt;br /&gt;
** Started project for Rich Client GUI migration from Java desktop application to build into SLicer4 QT modules. This affects mostly front-end GUI and has the following approaches: distribution with the Slicer4, end-user will select desired workflow application from Slicer4 menu while QT-written modules provide with the same functionality as Java Rich Clients. Case Study for the Migration process: registration suite for longitudinal studies that include multi-modality images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* '''3d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Concentrated on building downloadable workflow applications that could run both in desktop (new) and server environment, and that require minimum IT administrative resources. The desktop deployment is in compliance with Slicer3 general deployment concept.&lt;br /&gt;
*** The following use case scenario had been chosen: PET/CT image processing for longitudinal studies, EM Segmentation for longitudinal Aging Study.&lt;br /&gt;
** Released workflow application for PET/CT image processing for longitudinal studies. Provided end users with training and documentation.&lt;br /&gt;
*** The PET/CT processing workflow was designed to be a general application used whenever both structural patterns and metabolic activities are within the research scope. &lt;br /&gt;
*** The desktop version is tuned to use minimal computer resources, so the automates processing instances do not interfere with human activities. Automated activities may include, for example, registration and PET scan's standard uptake values computing, and manual human activities may include image cropping, quality control, and labeling voxels of interest.&lt;br /&gt;
** Core services and EM Segmentation preprocessing workflow was build for retrospective Aging Study. Tuned the Slicer3 webservices for processing low grade images acquired in mid 90s. Entire workflow is implemented with Slicer3 only modules and can be deployed locally and on the servers. Usage of Service Oriented Architecture (SOA) as a core technological approach allowed reusing most of the web services that had been build for PET/CT project. &lt;br /&gt;
** Continued embedding Slicer3 application and modules into previously released processing pipelines: replaced MIPAV with Slicer3 GUI for lesion assessment step in the multi-center Pediatric MS Cohort image processing &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''2d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Completed Social Cognition Workflow Implementation. This includes EM Segmetnation pre- and post-processing pipelines, data tracking, and integration with 3d party image processing utilities, as well as processing results acquired manually with Slicer GUI.  &lt;br /&gt;
** Multi-modality image registration and ROI selection/alignment workflow for longitudinal studies. &lt;br /&gt;
*** Use case: PET/CT image processing for longitudinal studies. &lt;br /&gt;
*** Build portable library of Slicer modules as web services and workflow that are deployed and run on a end-users' worksatations without utilization of SPL and other servers. The web services include novel Slicer3 modules, such as BRAINSFit and BRAINSResamle &lt;br /&gt;
*** Started working with Slicer3 developers on Slicer 3.8 GUI wizard to communicate with workflow instances.&lt;br /&gt;
** Participated at NA-MIC Summer 2010 Project Week: [[Summer_project_week_2010_Workflows_SOA]]&lt;br /&gt;
&lt;br /&gt;
=Progress=&lt;br /&gt;
* August 1, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT&lt;br /&gt;
* Follow-up with end users with new Study setup&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
CARMA Project&lt;br /&gt;
* Documentation (Work in progress)&lt;br /&gt;
* Plans for next week: custom packaging (Mac Snow Leopard 64 bit), building extension, documentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation&lt;br /&gt;
* Stress-test of online segmentation requests suite for  [http://www.slicer.org/slicerWiki/index.php/EMSegmenter-Tasks#Additional_Use_Cases CLIMB Study](for BWH MS Center)&lt;br /&gt;
* Reason for building online suite: the Group is Using mostly MAC OS Tiger machines for legacy reasnos, the most recent Slicer3 builds as well as QT don't work on those machines (QT4.x runtime could not be installed).&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* July 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA Project&lt;br /&gt;
* Documentation (Work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation&lt;br /&gt;
* Work on alpha-release of online submission of segmentation requests (for BWH MS Center)&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* July 22, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
Vacation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* July 8, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
3D Slicer in General and CARMA Project&lt;br /&gt;
* Presentation and life demo at Cardiology Research Center (Moscow, Russia) [[File:RussianCardiologyCenterCARMA2011.ppt]]&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* July 1, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA V1.0&lt;br /&gt;
* Migration to new QT building environment (Mac 10 Snow Leopard). &lt;br /&gt;
* Building custom package. Issues: new features (not only WF related) are not shown on the menu of the resulting application&lt;br /&gt;
* Comparing preprocessing workflow results with published in literature data (our module produces better alignment)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*June 24, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
Project Week:&lt;br /&gt;
* Testing RSS module for left atrial wall scar segmentation&lt;br /&gt;
* Testing EM Segmenter for lesion detection on PD (requested by end-users) and FLAIR images&lt;br /&gt;
&lt;br /&gt;
EM Segmentation &lt;br /&gt;
* Web-based segmentation and registration module for MS Center. Goal: facilitate 3D SLicer modules for the cases that could not be processed with in-house build DTS+ algorithm&lt;br /&gt;
* Pipeline: Segment MPGR or T1 (user's choice), Register MPGR to PD/T2, Resample Segmentation Map to PD/T2. Completion: 60-70%.&lt;br /&gt;
* The rest will be done manually or via lesion segmentation with EM Segmenter.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* June 17, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
Preparation for Project Week&lt;br /&gt;
&lt;br /&gt;
* June 10, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
CARMA V.1.0&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code completed and tested&lt;br /&gt;
* Packaging as extension is pending (Subject for Summer 2011 Project week)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Debugging consolidation results issue(SUVs for manual and automated segmentation) &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* June 3, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Deployed on end-user's machine&lt;br /&gt;
* TODO next week: fix SUV results consolidation issue (when MRI segmented ROI got SUV computed for some subjects, only those subjects' SUVs are being added into consolidated report. &amp;quot;Raw&amp;quot; SUV values per subject are generated as expected)  &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 27, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Ready for deployment. New Features: hemispheres EM Segmentation, automated ICC/brainmask extraction using EM Segmenter, fixed controls for MRI conversion and registration&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 20, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General / PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Hemispheres EM Segmentation - adjusted for required label lookup table&lt;br /&gt;
* Use cases added for EM Segmenter General Project: http://www.slicer.org/slicerWiki/index.php/EMSegmenter-Tasks#EMSegmenter_use_cases&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SPECTRE Scull Stripping&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* The new version to be tested on coming week (After PETCT MRI processing migrated to Hemispheres scenario )&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* May 13, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General / PETCT V1.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Hemispheres EM Segmentation - technically works with labal values hardcoded in Slicer EM Segmenter - need to add manual label value edition step&lt;br /&gt;
* PETCT WF Cut for Java GUI (Pending Hemispheres label update completion). Next release will be in QT4.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* May 6, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (QA of EM Segmenter module, work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* April 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Open Discussion for Packaging WF QT Modules as Slicer4 extensions (waiting for SOPs)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review supported projects http://wiki.na-mic.org/Wiki/index.php/File:SlicerWF_EMSegmentProjectsReview.zip &lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (required by Study)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Slicer Modules General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Standardizing Crop Volumes Output (with A. Fedorov's module). Review for required updates of existing product (PET/CT, CARMA)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Open Discussion for Packaging WF QT Modules as Slicer4 extensions (waiting for SOPs)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review supported projects http://wiki.na-mic.org/Wiki/index.php/File:SlicerWF_EMSegmentProjectsReview.zip &lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (required by Study)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Slicer Modules General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Standardizing Crop Volumes Output (with A. Fedorov's module)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 22, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Beta release ready. Demo Location: http://cni29.bwh.harvard.edu/SlicerWFDemo/index.php&lt;br /&gt;
* TODO: Tutorial. Original inputs copy/renaming&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 15, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Adding App server auto-config features&lt;br /&gt;
* Finalizing the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 08, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Second release beta build tested on cosutmer side &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review registration quality (with Dr. Meier). Angiography images' Resampling tuned. &lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 01, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the second release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
XNat Integration&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* (Java) GUI for Project Browsing and DICOM Series Upload. Post-upload DICOM processing tested and debugged&amp;lt;br&amp;gt;&lt;br /&gt;
* Ready for integration with mi2b2 client.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Migrated to Latest Slicer 3.6.3 stable release: only the Input scene had to be updated, the API remained the same&lt;br /&gt;
* Tested EM Segmenter with CMTK4Slicer extension - processing takes to much time on Linux_64bit machine, rolled back to BRAINSFit registration. When used on Mac OS X build, the Slicer could not start (bug report 1126).&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SPECTRE Scull Stripping:&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Testes for various use cases: the module is extremely sensitive to T1 MRI quality (does not work for most MRIs from PET/CT project&lt;br /&gt;
* TODO next week: check for FLAIR images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Slicer4 QT GUI and Cropping activity in progress.&amp;lt;br&amp;gt;&lt;br /&gt;
* Tried direct MRA to MRA registration option: resampling with LMRI registration transforms works better.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Extra VOI labels revised&lt;br /&gt;
* Debugging of SUV results' renormalization step&lt;br /&gt;
* TODO: ICC extraction / whole brain total uptake computing; EM Segmentation for R_WM, L_WM SUV computing and BPH estimation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SCULL STRIPPING/SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Installed and tested CLI option on Linux_64bit platform&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Workflow interruption before BSPline registraton: BPEL Module completed. Slicer4 QT GUI and Cropping activity in prorgess.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Implemented and Tested with end-users proposed changes: denormalization of SUV results, adding more VOI labels, added FLAIR MRI in addition to T1s for VOI drawing&lt;br /&gt;
* Tested manual ICC extraction using PET scans: works satisfactory with island removal and cropping followed by threshold level labeling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4&lt;br /&gt;
* Change proposed: interrupt workflow after affine registration and have user crop the VOI. This is to prevent excessive deformations for BSpline registration and resampling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4. User has option to choose the atlas that fits better for the given subject (NOTE: hardcoding must be rewritten for atlas linking)&lt;br /&gt;
* PETCT test - the problem is that T1s are low resolution and with contrast. Proposed using T1s without contrast&lt;br /&gt;
* PETCT change request: users wants to compute SUV for entire ICC. Had demo how to segment brainmask/ICC using PET scan. The derived brainmask label can be used for SUV computation.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - cmpleted&lt;br /&gt;
* Sample cases run - excessive deformation after BSpline registration hase&lt;br /&gt;
* Next week plan - pull tuning controls to front-end of pipeline API, start working of QT module for CARMA registration&lt;br /&gt;
* May consider other than BRAINSFit registration modules&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Design plan for change request: more VOI labels, add FLAIR in addition to T1 for VOI drawing, T1s segmentation&lt;br /&gt;
* Tested segmentation for sample cases - artifacts from poor quality MRIs lead to exclusion of parts of ICC from segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Completed troubleshooting of EMSegmenter module calling from Java (need TCL libs to be pulled from Slicer environment)&lt;br /&gt;
* Tested EMSegmenter autoruns for HIV and Pediatric MS patiens. Work as expected, subject to improvement of PED MS case segmentation by building better skull/neck/air atalses&lt;br /&gt;
* Suggested usage of two subsets of atalases: with and without neck. The Subject MRIs have to be cropped accordingly or best fit atlas has to be selected&lt;br /&gt;
* Made no-neck cropped atlas collection for default EMSegmenter scenario&lt;br /&gt;
* Tested with PET/CT study MRI cases - see above &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - in progress&lt;br /&gt;
* Next week goal - have back end processing ready&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Longitudinal Study&lt;br /&gt;
* Added MRI registration to the pipeline&lt;br /&gt;
* Troubleshooting of complex XML schema issues on Linux machines (some modules working on MAC do not work on Linux). As a workaround - did not include MRI convert and register part into base BPEL module. Used separate services (transparent for end-user)&lt;br /&gt;
* TODO next week for change request completion: explicit pixel type casting for MRI in BRAINSFit, VOI MRML scene update (currently MRI added on top of schema)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* February 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipeline for Pediatric MRI. Same scenario as for HIV Project, icbm pediatric atlases (Completed, verified)&lt;br /&gt;
* Collected NIH healthy brain development atlases: various age ranges from 4.5 to 18 yo. Converted to Slicer readable format &lt;br /&gt;
* Work on web services for the new automated EM Segmenter module (release Nov 10 - current). Verified task completion both for adult and pediatric images. Discussed tuning parameters for work load balance on workstations.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Started working on MRI registration to the reference CT scans. &lt;br /&gt;
* Design specs for optional White Matter segmentation for SUV computing.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* February 4, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipelines for Pediatric MRI (in progress)&lt;br /&gt;
* Adapting Pediatric T1 atlases for &amp;quot;Human Brain&amp;quot; build-in EM Segmentation wizard (in progress)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 28, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Verifying EM Segmenter module for latest builds and HIV/PED MS Studies (report pending)&lt;br /&gt;
* Work with SPECTRE module developers with pediatric MRI brainmask extraction&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* January 21, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Compiling plan for WF FrontEnd GUI migration to Slicer4/QT Widgets&lt;br /&gt;
* Preparing for annual progress report&lt;br /&gt;
&lt;br /&gt;
* January 14, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI: Integrated into the Slicer4 as Slicelet (or thin Client)&lt;br /&gt;
* Participation at AHM-2011, discussing integration of SPECTRE module and updated approach to EM-Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA&lt;br /&gt;
&lt;br /&gt;
* January 7, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* HIV project workflow delivered. Major additions relate to user convenience: &lt;br /&gt;
- Project-specific parameter settings, importing T1s and brainmasks from FreeSurfer outputs with conversion to NIFTI, resampling brainmask to original scans and automatied subject addition.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Follow up with end user: need to add MRI scans, if available, addition and registration to CT in order to ease VOI drawings.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
 &lt;br /&gt;
* December 31, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Follow-up with user Experience for AGING Study Segmentation (Positive feedback)&lt;br /&gt;
* Target date for HIV project delivery - next week&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Self-training for QT widget development&amp;lt;br&amp;gt;&lt;br /&gt;
* Outlined Workflow Rich Clients migration strategy from Java to QT/Slicer4:&amp;lt;br&amp;gt;&lt;br /&gt;
** Use Java Stubs (similar to SPECTRE integration) or file binding for envocation of workflow pipelines. (See SOAP remark below)&lt;br /&gt;
** Direct Web Servisec calls must be wrapped into REST protocol. The reason: NON-commerchial QT kit does not include SOAP protocol for web servises.&lt;br /&gt;
** The GUI will be implemented as page widget or QT dialog GUI forms called from within Slicer4.&lt;br /&gt;
** Communications between Slicer4 and WF GUI will be set via child-parent and signal-slot relations&lt;br /&gt;
* Worked on a Prototype for Basic EM Segmentation QT widget (70% complete). Will work on integrtion with SLicer4 during the AHM-2010&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
XNAT Integration&lt;br /&gt;
* Debugged XNAT RESTFul API usage for uplaoding DICOM series followed by header data extraction and image snapshots creation&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Added compensation for failed atlas registration (subject for old poor quality pseudo-T1 images): blank probability maps are created in case of failure.&lt;br /&gt;
* Data preparation module for FreeSurfer data import near completion. Expected time for deployment at end-users workstations - first week of January&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Discussed strategy for EM Segmentation pipeline solutions collection (K. Pohl, R. Kikinis)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* RE-using the same core workflow as for 1-channel EM Segmentation of AGING STUDY cases&lt;br /&gt;
* Added data input preparation module: ICC label mask preparation and skull-stripping based on FreeSurfer brainmask output volume.&lt;br /&gt;
* Two-channel EM segmentation pipeline (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE / GENERAL Development &amp;lt;br&amp;gt;&lt;br /&gt;
* Worked on plans for migrating fro rich workflow Java clients to embedded workflow windows inside the Slicer.&amp;lt;br&amp;gt;&lt;br /&gt;
The embedded workflow management clients are to be implemented with QT/PyQT toolkits&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
INTEGRATION WITH XNAT:&amp;lt;br&amp;gt;&lt;br /&gt;
* Automated DICOM series upload with triggering DICOM headers parsing at XNat site (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress. &lt;br /&gt;
- Results upload to XNat (Completed) &amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat based on user's input (Project + Subject + PET or CT session / scan) (Completed)&amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat - perfomance boosting solution for downloads found , web services services are created, relinking for the client side in progress &amp;lt;br&amp;gt;&lt;br /&gt;
- Xnat querying for subjects and automated subject addition into the workflow (In Progress) &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-segmentation module added for auto correction of segmentation results. Particularly - relabeling CSF voxels segmented as Air inside the intracranial cavity. This was requested by end-users after processing images with zero-signals in CSF voxels &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting automated dual-echo DICOM images conversion and split into two NRRD volumes&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT / EM Segmentation pipeline:&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting memory allocation issues for scull-stripping module SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
COPD Project:&amp;lt;br&amp;gt;&lt;br /&gt;
* Benchmark test for accelerated DICOM downloads from XNat (remoote XNat Central server): we can handle at least 6 cases (4 CT scans in each) per hour, which is compatible with current workload quotes on SPL cluster processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* December 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Deployed Version 1. &amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Test project chosen as a closest match to registration scenario: Pediatric MS Cases from MGH - requires periodic image preview for different &lt;br /&gt;
modalities taken from vaious time points. Label maps for VOIs resampling is also required.&lt;br /&gt;
&lt;br /&gt;
* November 26, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user. Version 1 is complete&amp;lt;br&amp;gt;&lt;br /&gt;
* Started working on integration with XNat&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on input data organizing modules&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 19, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user (70% done)&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Universal Registration Workflow for Longitudinal Studies - design specs in progress&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 12, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Minor tuning to EM Segmentation template as of users' feedback&lt;br /&gt;
* Users started using the workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed input data conversion from Genesis to Slicer native or NIFTI format. Our help may be needed in input data organizing.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Tuned application according to co-laborators (PNL) needs&amp;lt;br&amp;gt;&lt;br /&gt;
* The webservices and BPEL workflow application are tested ready to accept computation requests from PNL case tracking system &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Discussed Universal Registration Workflow for Longitudinal Studies&lt;br /&gt;
* Started the thread about possible cooperation with Children hospital's image processing pipelines and integration with Xnat &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 5, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Webservices and workflow pilot project created and deployed on Psychiatry Neuroimaging Laboratory subnet &amp;lt;br&amp;gt;&lt;br /&gt;
* The V.1.0 deployment is scheduled for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 29, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Most of functionality is completed. Some volume statistics post processing is pending&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL EM SEGMENTATION Pipeline: &amp;lt;br&amp;gt;&lt;br /&gt;
* The SPECTRE scull stripping module. Started integration into EMS workflow. Made some test runs from Slicer GUI&amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Identified as a candidate for Workflow Application&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 22, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* All back-end functionality are implemented&amp;lt;br&amp;gt;&lt;br /&gt;
* EM Segmentation scene usability is confirmed by end-user&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for next week: add Label Statistics computation for CSF/Brain/ICC &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 15, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* The latest (October) builds of Slicer 3.6.2 produced acceptable results. This was verified by the target users. The EM Segmentation will be performed on Slicer 3.6.2 or later&amp;lt;br&amp;gt;&lt;br /&gt;
* The new Web services had been created and added to the pipeline as optional processing steps: Biasfield correction (implement novel N2ITKBiasFieldCorrection module) and Volume's scalar datatype casting (as workaround for Biasfield correction module not preserving image scalar datatype - the bug is filed) &amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed the Front-End GUI design with target users. The design pattern is taken from the PETCT project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 8, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-deployment support. Tuned CT registration as of user's feedback.&lt;br /&gt;
* Adapting to the Single Slicer build: Slicer 3.6.2. Found label duplicates in the label lookup table - will ask user if it's tolerable. Waiting for the Slicer 3.6.2 build that contains all required modules. Rolling back label tag appending code for SUVs - the latest Slicer build appends the tags.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Resumed development. The priorities are set for usage of Slicer 3.6.2 - subject for EM Segmentation scene tuning. Continued coding for Scene creation for Slicer 2.8 - as a backup option for ongoing research project.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 1, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized V1.0 release based on end-user feedback: updates relate mostly to error proofing and SUV values representation&lt;br /&gt;
* Post-deployment support. Users pre-processed first set of patients &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* September 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* System deployed and tested at End Users' site.&amp;lt;br&amp;gt;Users are trained to perform all tasks required by the workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
* Got positive feedback with suggestions on Slicer Scenes' layouts improvement and PET scans' SUV (standard uptake values) results display&lt;br /&gt;
* Two distribution packages are assembled: Lunix and MAC OS versions. The difference in two packages is in specific Slicer3.6/3.7 builds - subject to Slicer Linux builds debugging.&amp;lt;br&amp;gt; As a workaround for Linux deployment - multiple Slicer builds are used to perform various tasks (registration, opening editing scenes in Slicer, SUV computing)&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for coming week - finalize V1.0 release based on end-user feedback&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Embedded SUV computations into the workflow (as system calls - will be translated into web service later)&amp;lt;br&amp;gt;&lt;br /&gt;
* Pre-release demo for end users.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Create and debug EM Segmenter scenes template for Slicer 3.6 and 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* September 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation - workflow pipeline and deployment verified&amp;lt;br&amp;gt;&lt;br /&gt;
* Tested EM Segmentation scenes within Slicer 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
* Started migration of EM Segmentation to Slicer 3.6. Discovered issues had been reported to EM Segmenter module designers &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* August 29 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation completed. Preprocessing Pipleine completed 80% (subject for input registration parameters tuning) &amp;lt;br&amp;gt;&lt;br /&gt;
* Most webservices (for registration and resampling steps) had been taken and re-used from PET/CT ROI/Longitudinal Study - showing the advantage of service-oriented software design and deployment.&lt;br /&gt;
* Continued on distribution and deployment of the service/workflow applications: on PET/CT and AGING STUDY projects.&lt;br /&gt;
&lt;br /&gt;
PEDIATRIC Multiple Sclerosis Cohort. Support of multi-center distributed processing project&amp;lt;br&amp;gt;&lt;br /&gt;
* Introduced Slicer 3.6 for the MS Lesion Assessment step performed at Mayo Clinic. Images are being transferred from image repository at BWH and automatically opened and arranged within Slicer GUI for reading.  This was replacement of Client GUI using MIPAV that stopped working on new computers at Mayo Clinic.&lt;br /&gt;
The images are being loaded via generated MRML Scenes same way as in PET/CT and AGING STUDY projects &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* August 22 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Preprocessing pipeline merge with SUV computations &amp;lt;br&amp;gt;&lt;br /&gt;
- QA for SUVs computation was performed by Wendy Plesniak for images with known uptake values. &amp;lt;br&amp;gt;&lt;br /&gt;
- Discovered that image cropping step (not related to automated registration pipeline and SUVs computing) smoothes the images by doing interpolation when used with default settings. Got suggestions from Steve Piper using Nearest-Neighbor interpolation (&amp;quot;no interpolation&amp;quot;) for a time being&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
- This is the new project candidate. Requested for the images with failed manual segmentation and/or segmentation with FreeSurfer. The EM Segmentation run showed most acceptable results on one of the problem images back in February &amp;lt;br&amp;gt;&lt;br /&gt;
- The workflow will be developed and deployed similar to PET/CT ROI Longitudinal study approach - all preprocessing steps will be done with Slicer modules, all runs will be performed on local end-user machines.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
 &lt;br /&gt;
&lt;br /&gt;
* August 15 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- First 5 cases with 3-4 time points preprocessed for SUVs computation&lt;br /&gt;
&lt;br /&gt;
* August 8 2010&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Testing of installation and operation at users' site (Performed by Wendy Plesniak)&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* July 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Delivered beta version of registration pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
- Prepared installation and user manuals &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* June 11, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Registration modules completed &amp;lt;br&amp;gt;&lt;br /&gt;
- Irregular cases registration problem solved (when whole body and brain only scans are mixed for a timepoint)&amp;lt;br&amp;gt;&lt;br /&gt;
- Live demo of case setup and registration workflow for end users. Real case with 4 timepoints used&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Coming week plans&amp;lt;br&amp;gt;&lt;br /&gt;
- Adjust workflow based on end users' feedback&amp;lt;br&amp;gt;&lt;br /&gt;
- Integration with SUVs computing for PET scans&amp;lt;br&amp;gt;&lt;br /&gt;
- GUI for workflows dispatching and data organizing&amp;lt;br&amp;gt;&lt;br /&gt;
- (TBD) Integration with 4D time series analysis Slicer module&amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
* May 28, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- Migration to the latest Slicer 3.6 release candidate &amp;lt;br&amp;gt;&lt;br /&gt;
- Added webservice for new registration module: BRAINSFit &amp;lt;br&amp;gt;&lt;br /&gt;
- Test runs for new patients with 4 timepoints' scans &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Plans for next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI &amp;lt;br&amp;gt;&lt;br /&gt;
- processing workflow demo for end user &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 21, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Pilot version of portable web services and automated workflow tested: &amp;lt;br&amp;gt;&lt;br /&gt;
Linux: workflow and visual review passed&amp;lt;br&amp;gt;&lt;br /&gt;
Stress test for 25 timepoints passed &amp;lt;br&amp;gt;&lt;br /&gt;
MAC OS: workflow passed, visual review failing when PET/CT images are loaded into GUI simultaneously (bug report submitted)&amp;lt;br&amp;gt;&lt;br /&gt;
Windows: need to adapt command line modules and workflow management system to sygwin environment&amp;lt;br&amp;gt;&lt;br /&gt;
Plans for next week: integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI&lt;br /&gt;
&lt;br /&gt;
* May 7, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Selected registration and resampling modules with more precise and stable outputs. &amp;lt;br&amp;gt;&lt;br /&gt;
Started building portable web services and automated workflow &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 30, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- manual walk through the processing steps: ROI cropping, registration/resampling, PET pharmaceutical DICOM data retention. &amp;lt;br&amp;gt;&lt;br /&gt;
- testing workflow and web services packages distribution to end-users' machines&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* April 23, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : testing various registration and re-sampling algorithms (work in progress)&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation: as of collaborators' request, run existing EM Segmentation workflow for older low resolution pseudo-T1 images. The EM Segmentation works for those images with manual sampling. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 16, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
  Social Cognition Study: started Cortical Thickness Measurement module build (bases on NA-MIC ARCTIC pipeline) &amp;lt;br&amp;gt;&lt;br /&gt;
  PET/CT ROI/Longitudinal Study Registration : Design specs, PET-to-CT images registration tests on training data. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 9, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. GUI update based on end-user experience.&amp;lt;br&amp;gt;&lt;br /&gt;
User request: automated label maps' volumes calculation (Currently possible from Slicer3 GUI)&amp;lt;br&amp;gt; &lt;br /&gt;
PET/CT ROI Project. Initial design specs discussion with end-users and co-developers&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure&lt;br /&gt;
Verification of segmentation workflow GUI: from registering new case to reviewing results&amp;lt;br&amp;gt;&lt;br /&gt;
Cross study test of segmentation workflow: MGH/MS Center data - success,  HIV Project data - some EM Segmentation scene tuning is needed &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*&lt;br /&gt;
* April 2, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. Segmentation workflow completed&amp;lt;br&amp;gt;&lt;br /&gt;
* Coming Week plans:&amp;lt;br&amp;gt;&lt;br /&gt;
- Document Segmentation Workflow. Follow up with end users &amp;lt;br&amp;gt;&lt;br /&gt;
- Start with Cortical Thickness and ROI-in-longitudinal studies workflows&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* March 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All essential processing and workflow interaction clients are ready.&amp;lt;br&amp;gt;&lt;br /&gt;
- Completed segmentation for 10 out of 50 patients. The remaining cases will be finalized upon manual lesion segmentation and QC verification of WM/GM/CSF and Deep GM segmentation's. &amp;lt;br&amp;gt;&lt;br /&gt;
- TODO next week: refine QC GUI and data tracking / progress monitoring schema. &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&amp;lt;br&amp;gt;&lt;br /&gt;
- New Slicer3 web services added: re-slicing with reference image volume, casting image scalar type &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
* March 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Segmentation maps Merging Services for GM/WM/CSF (Slicer EM Segemnter), Lesion (Slicer, Manual), and Deep GM (FreeSurfer)  &amp;lt;br&amp;gt;&lt;br /&gt;
- Deep GM segmentation pipeline adopted as optional service for Social Cognition Study (22 out of 50 cases processed) &amp;lt;br&amp;gt;&lt;br /&gt;
- (In progress) GUI client for Launching Segmentation results merging with optional Deep GM segmentation with FreeSurfer &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- Complete GUI Client for Segmentation result merging &amp;lt;br&amp;gt;&lt;br /&gt;
- Progress Monitoring services for entire Study processing: EM Segmenter Preprocessing, EM Segmentation, Lesion Segmentation (including human activities assignments), Deep GM segmentation, and results consolidation. &amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* March 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All 50 cases went through &amp;quot;basic&amp;quot; One-channel EM segmentation (GM/WM/CSF) &amp;lt;br&amp;gt;&lt;br /&gt;
- Basic pipeline start-up command line client created: user has two options - request brainmask extraction or provide with previously extracted brainmask for a given subject &amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison of GM/WN/CSF performed for Slicer EM Segmenter and FreeSurfer recon-all (used with default settings). &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmenter provides more accurate output &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmentation pipeline runs faster (40 minutes vs 12 hrs when no brainmask extraction requested) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO:&amp;lt;br&amp;gt;&lt;br /&gt;
- merging modules for automatic 1-channel EM segmentation and manual lesion segmentation &amp;lt;br&amp;gt;&lt;br /&gt;
- Emerge Cortical Thickness pipeline project: use NAC ARCTIC processing steps and modules &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Selected stable EM Segmentation scenario: White Matter, Gray Matter, and Cerebrospinal Fluid &amp;lt;br&amp;gt;&lt;br /&gt;
- First 16 cases are segmented for selected scenario. Nine more cases are preprocessed for EM Segmentation.&amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison to segmentation with FreeSurfer showed better accuracy for Slicer2 EMSegmenter &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure &amp;lt;br&amp;gt;&lt;br /&gt;
- Three prerpcocessed cases failed during volume ICC masking with in-house build utility. Evaluated switching to Slicer3 Mask and island removing modules.&amp;lt;br&amp;gt;&lt;br /&gt;
- Initial design specs discussion for cortical thickness measurement pipeline. ARCTIC pipeline selected. ARCTIC preprocessing steps signifficantly overlap with EM Segmentation preprocessing workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
  &lt;br /&gt;
* February 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: &amp;lt;br&amp;gt;&lt;br /&gt;
A) parameters tuning for EM Segmenter itself (work with EM Segmenter developer), template scenes creation &amp;lt;br&amp;gt;&lt;br /&gt;
B) update preprocessing pipeline - deep gray matter atlases included &amp;lt;br&amp;gt;&lt;br /&gt;
C) test and debug preprocesing pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
D) identified missing modules: atlas autocalibration for EM Segmentation scene, Island removal for ICC mask&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- Review currently deployed modules. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: reviewed firts seven subjects' outputs, added volume orientation module into pipeline (prevents ICBM atlas linear registration failures)&amp;lt;br&amp;gt;&lt;br /&gt;
- Fused ICC(brainmask) extraction module with EM Segmenter preprocessing. Three scenarious implemented: start with pre-extracted ICC mask (longitudinal studies case), run with ICC ectration, run with ICC extraction AND ICC correction before ICBM atlas preporcessing. &amp;lt;br&amp;gt;&lt;br /&gt;
- Completion of Human activities GUI (QC, ICC Correction) planned for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: Volume Orientation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: automated preprocessing pipeline for Slicer2 EM Segmenter test version deployed. Seven cases pre-processed.&lt;br /&gt;
- PET Quantitative measurements: Preliminary design specs discussion.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: BSplineRegistration (for non-linear registration), ResampleVolume2 (for atlases resampling based on image atlase templates registration). Local and Network runs are implemented, Cluster/GridWizard implementation pending.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Slicer EM Segmenter module: preprocessing design for Slicer2 EM Segmenter&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Adapting for Slicer2 EM Segmenter (mostly from pipelines and services for previous projects)&lt;br /&gt;
  -- Integration with FreeSurfer modules for bisafield correction, brainmask extraction, and linear registration of ICBM atlases&lt;br /&gt;
  -- Preprocessing updates for non-linear registration of ICBM atlases with Slicer2 (image re-orientation service designed)&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 29, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- EM Segmentaton pipeline: preprocessing results are being transferred to XNat (anonymized data, Central XNat) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Slicer EM Segmenter module: discussed agenda and scheduled a work meeting for Social Cognition Study image segmentation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Testing stage, 95% completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- SPL XNat server: verified data exchange via RESTfull web services.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 22, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Follow up with White Matter Lesion Segmenter and Scull Stripping Modules developers: Work in Progress&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Work in Progress, 60%+ completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Discussed SPINE image repository migration to XNat&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 15, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. &lt;br /&gt;
- Social Cognition Study: &lt;br /&gt;
Work-in-progress on intermediate (reconstruction) and results (resources) data storage at XNat.&lt;br /&gt;
&amp;lt;br&amp;gt;Reviewing and preparation more cases for EM Segmentor (Slicer 3.5) tuning.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* NA-MIC Project Week&lt;br /&gt;
Selecting candidate Slicer modules for other than Lesion EM Segmentation topics of Social Cognition study: Withe Matter Lesion Segmenter (UNC), Scull Stripping utility from UIOWA.&lt;br /&gt;
Reviewing issues of currently used Scull Stripping Slicer Extension and Slicer 3.5 EM Segmenter.&lt;br /&gt;
&amp;lt;br&amp;gt;XNat Data organizing training&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 1, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Preparation of Demo for NA-MIC work week: &lt;br /&gt;
- COPD Study. Added Remote pipepline start interface (represents real world scenario where Xnat repository, Processing modules and User are at different sites)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
- EM Segmentation. Added human activities steps to the workflow: ICC (brainmask) correction and EM Segmantation scena load per se.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 25, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Pilot workflow pipeline for EM Segmentation (all steps except user-activity step: ICC correction assignment and tracking)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 18, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Build and tested web services for EM Segmentation image preprocessing: DICOM-to-NRRD conversion, registration, skull stripping, image masking.&lt;br /&gt;
Started building workflow pipeline (subject to finish first version next week)&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Started Collecting Library of Slicer Build number vs. functional modules and extensions.&lt;br /&gt;
Plan for NAMIC project week: scheduled meetings for XNat data customization, Skull-stripping modules tuning, identified Social Cognition study cases that fail EM Segmentation processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 11, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Updating and verification of EM Segmentation Scenario&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Projects:ARRA:SlicerWF:UseCaseScenarios#Usecase_MS_lesion_Assessment&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Familiarizing with Slicer3.4/5 Modules required for implementation of EM Segmentation Scenario. Participation in debugging and/or usage tuning of Dicom Conversion, Registration, Skull Stripping, Masking, and Image Casting modules. &lt;br /&gt;
&lt;br /&gt;
* December 4, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Slicer3.4's EM Segmentation and Visual QC as part of image processing pipeline for Social Cognition Study for MS Patients.&lt;br /&gt;
Project emerged. EM Segmentation template creation debugged.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
Emphysema Measurements (COPD Study) - workflow stability and scalability test.&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 27, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Emphysema Measurements (COPD Study).&lt;br /&gt;
Added compensation for long running calculations and time-outs to the main computing pipeline.&lt;br /&gt;
Visual QC (work in progress)&lt;br /&gt;
** Infrastructure&lt;br /&gt;
XNat data structure customization, metadata storage, results consolidation: new feature request list creation (work in progress)&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 13, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
*** Pilot system for whole processing cycle for Emphysema Measurements (COPD Study) including the following:&lt;br /&gt;
Web query for CT session file list download&lt;br /&gt;
Pilot user interface for submitting the file list and starting processing pipeline&lt;br /&gt;
Notification about processing steps and failures&lt;br /&gt;
Upload results to XNat repository (at this stage results are uploaded into same folder where original scans are(*))&lt;br /&gt;
*** Immediate Plans&lt;br /&gt;
Complete Visual QC module&lt;br /&gt;
Design and implement meta-data transfer to XNat (including processing details and MRML files for loading images into the 3D Slicer)&lt;br /&gt;
&lt;br /&gt;
(*)Customization of results storage&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 6, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Tuned and debugged multiple subjects processing for: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat.&lt;br /&gt;
***Started working on quality control embedding into the above scenario. Plan to complete and video-record demo next week.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***Published general Product Integration scenario flow chart to collaborators' community. Discussion is open and in progress&lt;br /&gt;
&lt;br /&gt;
* October 30, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Piloted and tested the sequence: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat(1).&lt;br /&gt;
***Performance test of overall cycle: data transfer from remote serve is a bottleneck as expected&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data browsing features reviewed.&lt;br /&gt;
(1) Not automated yet&lt;br /&gt;
* October 23, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Defined COPD processing scenario with interoperability between Xnat, 3D Slicer Command Modules, Workflow, and Gridwizard Enterprise.&lt;br /&gt;
***Pilot version of Emphysema Measurements workflow pipeline deployed.&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data transfer features reviewed. Use account at XNat Central during learning curve.&lt;br /&gt;
***Feasibility test of 3D Slicer fiducials module for ROI highlights during QC and manual image processing activities. &lt;br /&gt;
* October 16, 2009&lt;br /&gt;
**Lung CT Scans Processing. Pilot project emerged. GenerateEmphysemaMeasurements module deployed as a webservice that submits jobs to computational cluster.&lt;br /&gt;
**EM Segmentation. Familiarized with GUI steps. Started working on automation steps outlining&lt;br /&gt;
**3D Slicer and XNat interaction. Got an overview from Wendy Plesniak.&lt;br /&gt;
* October 1 - 7, 2009&lt;br /&gt;
**Selected two first priority Projects: EM Segmentation of brain MRI images; Lung CT Scans Processing (COPD Study)&lt;br /&gt;
**Got initial outline of user requirements and design specs&lt;/div&gt;</summary>
		<author><name>Azaitsev</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=70189</id>
		<title>Projects:ARRA:SlicerWF</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=70189"/>
		<updated>2011-08-06T19:56:40Z</updated>

		<summary type="html">&lt;p&gt;Azaitsev: /* Progress */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Projects:ARRASuplements|Back to Slicer ARRA home page]]&lt;br /&gt;
= Aim =&lt;br /&gt;
Supplement 3D Slicer and Extensible Neuroimaging Archive Toolkit (XNAT) with workflow management system. Provide integration and interoperability between 3D Slicer, XNAT Services and 3-rd party image processing applications and high performance computing systems. Implement it as within currently developed Structural Planning and Implementation in Neurological Exploration (SPINE) System.&lt;br /&gt;
&lt;br /&gt;
= SPINE Project Documentation =&lt;br /&gt;
[http://cni.bwh.harvard.edu/projects/spine/index.html SPINE Docs]&lt;br /&gt;
&lt;br /&gt;
= Presentations =&lt;br /&gt;
* Segmentation Workflow. PECS University Social Cognition Study.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:SlicerWF_NAC_PECS_Workflow.pdf]]&lt;br /&gt;
* EAB10_ARRA Annual Progress Report Slides.&amp;lt;br&amp;gt;&lt;br /&gt;
[[media:EAB10_ARRA_WF_2011_Zaitsev.ppt | Service Oriented Solutions for 3D Slicer. EAB10_ARRA_WF_2011. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:EAB10_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:NAMIC_ARRA_WF_2011_Zaitsev.ppt  | NAMIC Annual Report 04/2010-03/2011. NAMIC_ARRA_WF_2011_Zaitsev. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:NAMIC_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:Slicer_WF_Slicer4CARMAWorkflow.ppt  | CARMA Workflow. Cardiac Ablation Followup. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:Slicer_WF_Slicer4CARMAWorkflow.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* CARMA Project Beta release Demo Location: http://cni29.bwh.harvard.edu/SlicerWFDemo/index.php&lt;br /&gt;
&lt;br /&gt;
* Segmentation Workflows: Screenshots, scans' and study description : [[File:SlicerWF_EMSegmentProjectsReview.zip]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
= All Hands Meeting Pages =&lt;br /&gt;
* Salt Lake City 2011 Winter [http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA SLC_2011_WorkFlow]&lt;br /&gt;
* MIT 2010 Summer [http://wiki.na-mic.org/Wiki/index.php/Summer_project_week_2010_Workflows_SOA MIT_2010_WorkFlow]&lt;br /&gt;
&lt;br /&gt;
= Research Plan =&lt;br /&gt;
*Create a stand-alone SPINE desktop agent with fully functional data exchange and communication mechanisms towards 3D Slicer and XNAT.&lt;br /&gt;
*Develop Service Oriented Architecture (SOA) SPINE System that will include 3D Slicer image processing modules deployed as web services as well as a workflow management system to orchestrate interaction between 3D Slicer, XNAT, and 3-rd party tools.&lt;br /&gt;
*Implement two-way control and communications between 3D Slicer and SPINE modules.&lt;br /&gt;
*Adapt SPINE System for cluster and grid computing scenarios.&lt;br /&gt;
*Provide with workflow and 3D Slicer web service wrappers editing tools.&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:UseCaseScenarios| Use Case scenarios]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PETCTWorkflow| PETCTWorkflow]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:AgingStudySegmentation| AgingStudySegmentation]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:TwoTensorTractography| TwoTensorTractography]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:LongitudinalMultimodalityRegistrationSuite| LongitudinalMultimodalityRegistrationSuite]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:MigrationJavaClients2QT| MigrationJavaClients2QT]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PediatricMSSegmentation| PediatricMSSegmentation]]&lt;br /&gt;
*[[DBP3:Utah:RegSegPipeline| MRI-based study and treatment of atrial fibrillation]]&lt;br /&gt;
&lt;br /&gt;
= Application Server / Workflow Engine Downloads =&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:WFEngineDownloads| Download Links]]&lt;br /&gt;
&lt;br /&gt;
=Key Personnel=&lt;br /&gt;
* Charles Gutmann, MD., 4%,  9-17-2009 through 9-16-2011&lt;br /&gt;
* Alexander Zaitsev, Ph.D., 75%, 9-17-2009 through 9-16-2011 &lt;br /&gt;
&lt;br /&gt;
=Annual Progress Statements =&lt;br /&gt;
'''2010-11''' &amp;lt;br&amp;gt;&lt;br /&gt;
The  April 2011 – March 2011 period was devoted on developing portable workflow solutions that can be deployed on end-users' workstations or notebooks with minimal or no system administration activities. This is in contrast to the server-side deployment. The following scenarios had been deployed and used for actual projects that require the following types of workflows: PET/CT registration and computation of biomarker driven brain physiological activities, Brain MRI Images segmentation,  MRI and MRI Angiography images pre-processing for cardiac ablation outcome estimation. Some  workflows (like EM Segmentation) had been utilizing various scenarios, some research projects  (like evaluation of chemotherapy outcome) require two types of workflows to assess physiological and structural changes. Starting from the 4th Quarter of 2011, the migration project had been emerged in order to embed Workflow GUIs into newly developed Slicer4 Suite. The existing rich client Java GUI applications are being re-written as C++/QT Sliceletts units, new modules (such as cardiac ablation project support) are had been written from scratch. The latter are being deployed from the Slicer4 GUI and act at a liaison between Slicer4 and Application Server containing  workflow and Slicer modules deployed as services. The feedback from the end users indicates that Workflow approach for the complex processing improves productivity, aids to the processing standardization and contributes to the overall experience using 3D Slicer&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
=Quarterly Progress=&lt;br /&gt;
&lt;br /&gt;
* '''2d Qtr, 2011''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study: Second release deployed. &lt;br /&gt;
*** End-users completed the first Project and currently analyzing SUV values and clinical data&lt;br /&gt;
*** New features added: Human Brain Hemispheres segmentation, Scull-stripping for total SUV counts calculation, Flexibility of custom designed label look-up table usage (users can define ROI notation according to the Project needs)&lt;br /&gt;
&lt;br /&gt;
** Left Atrium Ablation Assessment (CARMA Project)&lt;br /&gt;
*** Completed workflow pipeline for automated pre-processing and manual intervention&lt;br /&gt;
*** Developed front-end GUI for the CARMA Project support in Slicer4.&lt;br /&gt;
*** Run the workflow with the end users during NAMIC Project Week&lt;br /&gt;
*** Evaluated feasibility of left atrium wall and post-ablation scar segmentation using Robust Statistical Segmentation (RSS). Identified necessary processing controls with RSS module designers&lt;br /&gt;
&lt;br /&gt;
** Multiple Sclerosis CLIMB Study&lt;br /&gt;
*** Reprocessing for lesion segmentation&lt;br /&gt;
*** Developed Web-based (Java EE 6) application for submitting cases to the workflows for EM Segmentation of MPRAGE and registration to PD/T2/FLAIR images (60% completion)&lt;br /&gt;
&lt;br /&gt;
** EM Segmentation: &lt;br /&gt;
*** Upgraded EM Segmentation services to Slicer 3.6.4&lt;br /&gt;
*** Added brain hemispheres segmentation module to the workflows (used for PET/CT Longitudinal study)&lt;br /&gt;
*** Work with EM Segmenter module developers on building pipelines for white matter lesion segmentation (work in progress)&lt;br /&gt;
&lt;br /&gt;
** Plans for the 3rd quarter&lt;br /&gt;
*** Migrate CARMA Project workflow to end-users&lt;br /&gt;
*** Packaging of Slicer4 Workflow modules and Slicer4 custom build distribution &lt;br /&gt;
*** Completion of Web-base segmentation and registration suite&lt;br /&gt;
*** Users and Developers Documentation&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* NAMIC Annual Progress Slides (April 2010 - March 2011):&lt;br /&gt;
&lt;br /&gt;
* '''1st Qtr, 2011''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study: Second release is under testing by end-users. &lt;br /&gt;
*** Added MRI registration to aid ROI drawing on PET scans&lt;br /&gt;
*** Improved SUV results reporting and added flexibility to update ROI lookup table&lt;br /&gt;
*** Automated EM Segmentation of MRI images for computing SUVs for white matter, CSF, and whole brain (80% completion)&lt;br /&gt;
*** Integration with SPECTRE scull stripping module (70% completion) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** EM Segmentation: Automated WF Pipelines are created &amp;lt;br&amp;gt;&lt;br /&gt;
*** Flexible atlas selection (Pediatric, etc) feature added&lt;br /&gt;
*** Workflows implemented for EM Segmenter 3.6.2 and 3.6.3 (1st Qtr 2011 release)&lt;br /&gt;
&lt;br /&gt;
** Cardiac ablation results follow-up: Workflow for registration and ROI selection of cardiac MRI and MR Angiography &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Wrokflow and Web Services for prospective DTI tractography modules (currently written as Matlab modules at PNL) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Web Services for SPECTRE Scull stripping module&lt;br /&gt;
*** Accuracy and performance tuning&lt;br /&gt;
*** 50% completion&lt;br /&gt;
&lt;br /&gt;
** Migration Front End GUI to Slicer4/QT:&lt;br /&gt;
*** EM Segmentation&lt;br /&gt;
*** Cardiac Ablation Study&lt;br /&gt;
&lt;br /&gt;
** DICOM Uploader and Desktop Browser for XNat Image repository (alpha version - tested for MGH MS Center studies, proposed to use with MI2B2 Clients and Services)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''4th Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study and EM Segmentation for Aging Study are deployed at end-user sites and actively used for research. &lt;br /&gt;
** Adopted EM Segmentation preprocessing pipeline for HIV Study: high resolution SPGR images, integration with FreeSurfer brainmask extraction outputs; integration of Slicer SPECTRE module for brainmask extraction is in progress.&lt;br /&gt;
** The following post-release upgrades had been implemented based on end-user feedback: Application Server basic controls are performed from Rich Client GUI as alternative to traditional IT administration activities. The controls are implemented on point-and-click bases and include web services and workflow application deployment and upgrades, application server start and stop as well as warning end user when the server is not accepting request.&lt;br /&gt;
** Added DICOM downloads and results uploads of PET/CT pipelines from and to XNat Repository&lt;br /&gt;
** Created Services and Workflow for Matlab Prototypes modules. Case Study: tractography for DTI images&lt;br /&gt;
** Extended XNAT integration services:&lt;br /&gt;
*** Browsing capabilities of XNat data repository from the Workflow Applications&lt;br /&gt;
*** Improved DICOM upload and download performance&lt;br /&gt;
*** Added Metadata organizing services for uploaded DICOM images: header data extraction, image snapshots creation. &lt;br /&gt;
** Started project for Rich Client GUI migration from Java desktop application to build into SLicer4 QT modules. This affects mostly front-end GUI and has the following approaches: distribution with the Slicer4, end-user will select desired workflow application from Slicer4 menu while QT-written modules provide with the same functionality as Java Rich Clients. Case Study for the Migration process: registration suite for longitudinal studies that include multi-modality images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* '''3d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Concentrated on building downloadable workflow applications that could run both in desktop (new) and server environment, and that require minimum IT administrative resources. The desktop deployment is in compliance with Slicer3 general deployment concept.&lt;br /&gt;
*** The following use case scenario had been chosen: PET/CT image processing for longitudinal studies, EM Segmentation for longitudinal Aging Study.&lt;br /&gt;
** Released workflow application for PET/CT image processing for longitudinal studies. Provided end users with training and documentation.&lt;br /&gt;
*** The PET/CT processing workflow was designed to be a general application used whenever both structural patterns and metabolic activities are within the research scope. &lt;br /&gt;
*** The desktop version is tuned to use minimal computer resources, so the automates processing instances do not interfere with human activities. Automated activities may include, for example, registration and PET scan's standard uptake values computing, and manual human activities may include image cropping, quality control, and labeling voxels of interest.&lt;br /&gt;
** Core services and EM Segmentation preprocessing workflow was build for retrospective Aging Study. Tuned the Slicer3 webservices for processing low grade images acquired in mid 90s. Entire workflow is implemented with Slicer3 only modules and can be deployed locally and on the servers. Usage of Service Oriented Architecture (SOA) as a core technological approach allowed reusing most of the web services that had been build for PET/CT project. &lt;br /&gt;
** Continued embedding Slicer3 application and modules into previously released processing pipelines: replaced MIPAV with Slicer3 GUI for lesion assessment step in the multi-center Pediatric MS Cohort image processing &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''2d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Completed Social Cognition Workflow Implementation. This includes EM Segmetnation pre- and post-processing pipelines, data tracking, and integration with 3d party image processing utilities, as well as processing results acquired manually with Slicer GUI.  &lt;br /&gt;
** Multi-modality image registration and ROI selection/alignment workflow for longitudinal studies. &lt;br /&gt;
*** Use case: PET/CT image processing for longitudinal studies. &lt;br /&gt;
*** Build portable library of Slicer modules as web services and workflow that are deployed and run on a end-users' worksatations without utilization of SPL and other servers. The web services include novel Slicer3 modules, such as BRAINSFit and BRAINSResamle &lt;br /&gt;
*** Started working with Slicer3 developers on Slicer 3.8 GUI wizard to communicate with workflow instances.&lt;br /&gt;
** Participated at NA-MIC Summer 2010 Project Week: [[Summer_project_week_2010_Workflows_SOA]]&lt;br /&gt;
&lt;br /&gt;
=Progress=&lt;br /&gt;
* August 1, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT&lt;br /&gt;
* Follow-up with end users with new Study setup&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
CARMA Project&lt;br /&gt;
* Documentation (Work in progress)&lt;br /&gt;
* Plans for next week: custom packaging (Mac Snow Leopard 64 bit), building extension, documentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation&lt;br /&gt;
* Stress-test of online segmentation requests suite for  [http://www.slicer.org/slicerWiki/index.php/EMSegmenter-Tasks#Additional_Use_Cases CLIMB Study](for BWH MS Center)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* July 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA Project&lt;br /&gt;
* Documentation (Work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation&lt;br /&gt;
* Work on alpha-release of online submission of segmentation requests (for BWH MS Center)&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* July 22, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
Vacation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* July 8, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
3D Slicer in General and CARMA Project&lt;br /&gt;
* Presentation and life demo at Cardiology Research Center (Moscow, Russia) [[File:RussianCardiologyCenterCARMA2011.ppt]]&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* July 1, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA V1.0&lt;br /&gt;
* Migration to new QT building environment (Mac 10 Snow Leopard). &lt;br /&gt;
* Building custom package. Issues: new features (not only WF related) are not shown on the menu of the resulting application&lt;br /&gt;
* Comparing preprocessing workflow results with published in literature data (our module produces better alignment)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*June 24, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
Project Week:&lt;br /&gt;
* Testing RSS module for left atrial wall scar segmentation&lt;br /&gt;
* Testing EM Segmenter for lesion detection on PD (requested by end-users) and FLAIR images&lt;br /&gt;
&lt;br /&gt;
EM Segmentation &lt;br /&gt;
* Web-based segmentation and registration module for MS Center. Goal: facilitate 3D SLicer modules for the cases that could not be processed with in-house build DTS+ algorithm&lt;br /&gt;
* Pipeline: Segment MPGR or T1 (user's choice), Register MPGR to PD/T2, Resample Segmentation Map to PD/T2. Completion: 60-70%.&lt;br /&gt;
* The rest will be done manually or via lesion segmentation with EM Segmenter.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* June 17, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
Preparation for Project Week&lt;br /&gt;
&lt;br /&gt;
* June 10, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
CARMA V.1.0&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code completed and tested&lt;br /&gt;
* Packaging as extension is pending (Subject for Summer 2011 Project week)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Debugging consolidation results issue(SUVs for manual and automated segmentation) &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* June 3, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Deployed on end-user's machine&lt;br /&gt;
* TODO next week: fix SUV results consolidation issue (when MRI segmented ROI got SUV computed for some subjects, only those subjects' SUVs are being added into consolidated report. &amp;quot;Raw&amp;quot; SUV values per subject are generated as expected)  &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 27, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Ready for deployment. New Features: hemispheres EM Segmentation, automated ICC/brainmask extraction using EM Segmenter, fixed controls for MRI conversion and registration&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 20, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General / PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Hemispheres EM Segmentation - adjusted for required label lookup table&lt;br /&gt;
* Use cases added for EM Segmenter General Project: http://www.slicer.org/slicerWiki/index.php/EMSegmenter-Tasks#EMSegmenter_use_cases&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SPECTRE Scull Stripping&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* The new version to be tested on coming week (After PETCT MRI processing migrated to Hemispheres scenario )&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* May 13, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General / PETCT V1.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Hemispheres EM Segmentation - technically works with labal values hardcoded in Slicer EM Segmenter - need to add manual label value edition step&lt;br /&gt;
* PETCT WF Cut for Java GUI (Pending Hemispheres label update completion). Next release will be in QT4.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* May 6, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (QA of EM Segmenter module, work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* April 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Open Discussion for Packaging WF QT Modules as Slicer4 extensions (waiting for SOPs)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review supported projects http://wiki.na-mic.org/Wiki/index.php/File:SlicerWF_EMSegmentProjectsReview.zip &lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (required by Study)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Slicer Modules General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Standardizing Crop Volumes Output (with A. Fedorov's module). Review for required updates of existing product (PET/CT, CARMA)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Open Discussion for Packaging WF QT Modules as Slicer4 extensions (waiting for SOPs)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review supported projects http://wiki.na-mic.org/Wiki/index.php/File:SlicerWF_EMSegmentProjectsReview.zip &lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (required by Study)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Slicer Modules General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Standardizing Crop Volumes Output (with A. Fedorov's module)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 22, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Beta release ready. Demo Location: http://cni29.bwh.harvard.edu/SlicerWFDemo/index.php&lt;br /&gt;
* TODO: Tutorial. Original inputs copy/renaming&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 15, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Adding App server auto-config features&lt;br /&gt;
* Finalizing the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 08, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Second release beta build tested on cosutmer side &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review registration quality (with Dr. Meier). Angiography images' Resampling tuned. &lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 01, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the second release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
XNat Integration&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* (Java) GUI for Project Browsing and DICOM Series Upload. Post-upload DICOM processing tested and debugged&amp;lt;br&amp;gt;&lt;br /&gt;
* Ready for integration with mi2b2 client.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Migrated to Latest Slicer 3.6.3 stable release: only the Input scene had to be updated, the API remained the same&lt;br /&gt;
* Tested EM Segmenter with CMTK4Slicer extension - processing takes to much time on Linux_64bit machine, rolled back to BRAINSFit registration. When used on Mac OS X build, the Slicer could not start (bug report 1126).&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SPECTRE Scull Stripping:&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Testes for various use cases: the module is extremely sensitive to T1 MRI quality (does not work for most MRIs from PET/CT project&lt;br /&gt;
* TODO next week: check for FLAIR images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Slicer4 QT GUI and Cropping activity in progress.&amp;lt;br&amp;gt;&lt;br /&gt;
* Tried direct MRA to MRA registration option: resampling with LMRI registration transforms works better.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Extra VOI labels revised&lt;br /&gt;
* Debugging of SUV results' renormalization step&lt;br /&gt;
* TODO: ICC extraction / whole brain total uptake computing; EM Segmentation for R_WM, L_WM SUV computing and BPH estimation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SCULL STRIPPING/SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Installed and tested CLI option on Linux_64bit platform&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Workflow interruption before BSPline registraton: BPEL Module completed. Slicer4 QT GUI and Cropping activity in prorgess.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Implemented and Tested with end-users proposed changes: denormalization of SUV results, adding more VOI labels, added FLAIR MRI in addition to T1s for VOI drawing&lt;br /&gt;
* Tested manual ICC extraction using PET scans: works satisfactory with island removal and cropping followed by threshold level labeling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4&lt;br /&gt;
* Change proposed: interrupt workflow after affine registration and have user crop the VOI. This is to prevent excessive deformations for BSpline registration and resampling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4. User has option to choose the atlas that fits better for the given subject (NOTE: hardcoding must be rewritten for atlas linking)&lt;br /&gt;
* PETCT test - the problem is that T1s are low resolution and with contrast. Proposed using T1s without contrast&lt;br /&gt;
* PETCT change request: users wants to compute SUV for entire ICC. Had demo how to segment brainmask/ICC using PET scan. The derived brainmask label can be used for SUV computation.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - cmpleted&lt;br /&gt;
* Sample cases run - excessive deformation after BSpline registration hase&lt;br /&gt;
* Next week plan - pull tuning controls to front-end of pipeline API, start working of QT module for CARMA registration&lt;br /&gt;
* May consider other than BRAINSFit registration modules&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Design plan for change request: more VOI labels, add FLAIR in addition to T1 for VOI drawing, T1s segmentation&lt;br /&gt;
* Tested segmentation for sample cases - artifacts from poor quality MRIs lead to exclusion of parts of ICC from segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Completed troubleshooting of EMSegmenter module calling from Java (need TCL libs to be pulled from Slicer environment)&lt;br /&gt;
* Tested EMSegmenter autoruns for HIV and Pediatric MS patiens. Work as expected, subject to improvement of PED MS case segmentation by building better skull/neck/air atalses&lt;br /&gt;
* Suggested usage of two subsets of atalases: with and without neck. The Subject MRIs have to be cropped accordingly or best fit atlas has to be selected&lt;br /&gt;
* Made no-neck cropped atlas collection for default EMSegmenter scenario&lt;br /&gt;
* Tested with PET/CT study MRI cases - see above &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - in progress&lt;br /&gt;
* Next week goal - have back end processing ready&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Longitudinal Study&lt;br /&gt;
* Added MRI registration to the pipeline&lt;br /&gt;
* Troubleshooting of complex XML schema issues on Linux machines (some modules working on MAC do not work on Linux). As a workaround - did not include MRI convert and register part into base BPEL module. Used separate services (transparent for end-user)&lt;br /&gt;
* TODO next week for change request completion: explicit pixel type casting for MRI in BRAINSFit, VOI MRML scene update (currently MRI added on top of schema)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* February 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipeline for Pediatric MRI. Same scenario as for HIV Project, icbm pediatric atlases (Completed, verified)&lt;br /&gt;
* Collected NIH healthy brain development atlases: various age ranges from 4.5 to 18 yo. Converted to Slicer readable format &lt;br /&gt;
* Work on web services for the new automated EM Segmenter module (release Nov 10 - current). Verified task completion both for adult and pediatric images. Discussed tuning parameters for work load balance on workstations.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Started working on MRI registration to the reference CT scans. &lt;br /&gt;
* Design specs for optional White Matter segmentation for SUV computing.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* February 4, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipelines for Pediatric MRI (in progress)&lt;br /&gt;
* Adapting Pediatric T1 atlases for &amp;quot;Human Brain&amp;quot; build-in EM Segmentation wizard (in progress)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 28, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Verifying EM Segmenter module for latest builds and HIV/PED MS Studies (report pending)&lt;br /&gt;
* Work with SPECTRE module developers with pediatric MRI brainmask extraction&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* January 21, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Compiling plan for WF FrontEnd GUI migration to Slicer4/QT Widgets&lt;br /&gt;
* Preparing for annual progress report&lt;br /&gt;
&lt;br /&gt;
* January 14, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI: Integrated into the Slicer4 as Slicelet (or thin Client)&lt;br /&gt;
* Participation at AHM-2011, discussing integration of SPECTRE module and updated approach to EM-Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA&lt;br /&gt;
&lt;br /&gt;
* January 7, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* HIV project workflow delivered. Major additions relate to user convenience: &lt;br /&gt;
- Project-specific parameter settings, importing T1s and brainmasks from FreeSurfer outputs with conversion to NIFTI, resampling brainmask to original scans and automatied subject addition.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Follow up with end user: need to add MRI scans, if available, addition and registration to CT in order to ease VOI drawings.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
 &lt;br /&gt;
* December 31, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Follow-up with user Experience for AGING Study Segmentation (Positive feedback)&lt;br /&gt;
* Target date for HIV project delivery - next week&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Self-training for QT widget development&amp;lt;br&amp;gt;&lt;br /&gt;
* Outlined Workflow Rich Clients migration strategy from Java to QT/Slicer4:&amp;lt;br&amp;gt;&lt;br /&gt;
** Use Java Stubs (similar to SPECTRE integration) or file binding for envocation of workflow pipelines. (See SOAP remark below)&lt;br /&gt;
** Direct Web Servisec calls must be wrapped into REST protocol. The reason: NON-commerchial QT kit does not include SOAP protocol for web servises.&lt;br /&gt;
** The GUI will be implemented as page widget or QT dialog GUI forms called from within Slicer4.&lt;br /&gt;
** Communications between Slicer4 and WF GUI will be set via child-parent and signal-slot relations&lt;br /&gt;
* Worked on a Prototype for Basic EM Segmentation QT widget (70% complete). Will work on integrtion with SLicer4 during the AHM-2010&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
XNAT Integration&lt;br /&gt;
* Debugged XNAT RESTFul API usage for uplaoding DICOM series followed by header data extraction and image snapshots creation&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Added compensation for failed atlas registration (subject for old poor quality pseudo-T1 images): blank probability maps are created in case of failure.&lt;br /&gt;
* Data preparation module for FreeSurfer data import near completion. Expected time for deployment at end-users workstations - first week of January&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Discussed strategy for EM Segmentation pipeline solutions collection (K. Pohl, R. Kikinis)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* RE-using the same core workflow as for 1-channel EM Segmentation of AGING STUDY cases&lt;br /&gt;
* Added data input preparation module: ICC label mask preparation and skull-stripping based on FreeSurfer brainmask output volume.&lt;br /&gt;
* Two-channel EM segmentation pipeline (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE / GENERAL Development &amp;lt;br&amp;gt;&lt;br /&gt;
* Worked on plans for migrating fro rich workflow Java clients to embedded workflow windows inside the Slicer.&amp;lt;br&amp;gt;&lt;br /&gt;
The embedded workflow management clients are to be implemented with QT/PyQT toolkits&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
INTEGRATION WITH XNAT:&amp;lt;br&amp;gt;&lt;br /&gt;
* Automated DICOM series upload with triggering DICOM headers parsing at XNat site (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress. &lt;br /&gt;
- Results upload to XNat (Completed) &amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat based on user's input (Project + Subject + PET or CT session / scan) (Completed)&amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat - perfomance boosting solution for downloads found , web services services are created, relinking for the client side in progress &amp;lt;br&amp;gt;&lt;br /&gt;
- Xnat querying for subjects and automated subject addition into the workflow (In Progress) &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-segmentation module added for auto correction of segmentation results. Particularly - relabeling CSF voxels segmented as Air inside the intracranial cavity. This was requested by end-users after processing images with zero-signals in CSF voxels &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting automated dual-echo DICOM images conversion and split into two NRRD volumes&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT / EM Segmentation pipeline:&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting memory allocation issues for scull-stripping module SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
COPD Project:&amp;lt;br&amp;gt;&lt;br /&gt;
* Benchmark test for accelerated DICOM downloads from XNat (remoote XNat Central server): we can handle at least 6 cases (4 CT scans in each) per hour, which is compatible with current workload quotes on SPL cluster processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* December 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Deployed Version 1. &amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Test project chosen as a closest match to registration scenario: Pediatric MS Cases from MGH - requires periodic image preview for different &lt;br /&gt;
modalities taken from vaious time points. Label maps for VOIs resampling is also required.&lt;br /&gt;
&lt;br /&gt;
* November 26, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user. Version 1 is complete&amp;lt;br&amp;gt;&lt;br /&gt;
* Started working on integration with XNat&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on input data organizing modules&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 19, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user (70% done)&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Universal Registration Workflow for Longitudinal Studies - design specs in progress&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 12, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Minor tuning to EM Segmentation template as of users' feedback&lt;br /&gt;
* Users started using the workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed input data conversion from Genesis to Slicer native or NIFTI format. Our help may be needed in input data organizing.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Tuned application according to co-laborators (PNL) needs&amp;lt;br&amp;gt;&lt;br /&gt;
* The webservices and BPEL workflow application are tested ready to accept computation requests from PNL case tracking system &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Discussed Universal Registration Workflow for Longitudinal Studies&lt;br /&gt;
* Started the thread about possible cooperation with Children hospital's image processing pipelines and integration with Xnat &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 5, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Webservices and workflow pilot project created and deployed on Psychiatry Neuroimaging Laboratory subnet &amp;lt;br&amp;gt;&lt;br /&gt;
* The V.1.0 deployment is scheduled for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 29, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Most of functionality is completed. Some volume statistics post processing is pending&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL EM SEGMENTATION Pipeline: &amp;lt;br&amp;gt;&lt;br /&gt;
* The SPECTRE scull stripping module. Started integration into EMS workflow. Made some test runs from Slicer GUI&amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Identified as a candidate for Workflow Application&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 22, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* All back-end functionality are implemented&amp;lt;br&amp;gt;&lt;br /&gt;
* EM Segmentation scene usability is confirmed by end-user&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for next week: add Label Statistics computation for CSF/Brain/ICC &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 15, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* The latest (October) builds of Slicer 3.6.2 produced acceptable results. This was verified by the target users. The EM Segmentation will be performed on Slicer 3.6.2 or later&amp;lt;br&amp;gt;&lt;br /&gt;
* The new Web services had been created and added to the pipeline as optional processing steps: Biasfield correction (implement novel N2ITKBiasFieldCorrection module) and Volume's scalar datatype casting (as workaround for Biasfield correction module not preserving image scalar datatype - the bug is filed) &amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed the Front-End GUI design with target users. The design pattern is taken from the PETCT project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 8, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-deployment support. Tuned CT registration as of user's feedback.&lt;br /&gt;
* Adapting to the Single Slicer build: Slicer 3.6.2. Found label duplicates in the label lookup table - will ask user if it's tolerable. Waiting for the Slicer 3.6.2 build that contains all required modules. Rolling back label tag appending code for SUVs - the latest Slicer build appends the tags.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Resumed development. The priorities are set for usage of Slicer 3.6.2 - subject for EM Segmentation scene tuning. Continued coding for Scene creation for Slicer 2.8 - as a backup option for ongoing research project.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 1, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized V1.0 release based on end-user feedback: updates relate mostly to error proofing and SUV values representation&lt;br /&gt;
* Post-deployment support. Users pre-processed first set of patients &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* September 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* System deployed and tested at End Users' site.&amp;lt;br&amp;gt;Users are trained to perform all tasks required by the workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
* Got positive feedback with suggestions on Slicer Scenes' layouts improvement and PET scans' SUV (standard uptake values) results display&lt;br /&gt;
* Two distribution packages are assembled: Lunix and MAC OS versions. The difference in two packages is in specific Slicer3.6/3.7 builds - subject to Slicer Linux builds debugging.&amp;lt;br&amp;gt; As a workaround for Linux deployment - multiple Slicer builds are used to perform various tasks (registration, opening editing scenes in Slicer, SUV computing)&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for coming week - finalize V1.0 release based on end-user feedback&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Embedded SUV computations into the workflow (as system calls - will be translated into web service later)&amp;lt;br&amp;gt;&lt;br /&gt;
* Pre-release demo for end users.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Create and debug EM Segmenter scenes template for Slicer 3.6 and 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* September 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation - workflow pipeline and deployment verified&amp;lt;br&amp;gt;&lt;br /&gt;
* Tested EM Segmentation scenes within Slicer 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
* Started migration of EM Segmentation to Slicer 3.6. Discovered issues had been reported to EM Segmenter module designers &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* August 29 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation completed. Preprocessing Pipleine completed 80% (subject for input registration parameters tuning) &amp;lt;br&amp;gt;&lt;br /&gt;
* Most webservices (for registration and resampling steps) had been taken and re-used from PET/CT ROI/Longitudinal Study - showing the advantage of service-oriented software design and deployment.&lt;br /&gt;
* Continued on distribution and deployment of the service/workflow applications: on PET/CT and AGING STUDY projects.&lt;br /&gt;
&lt;br /&gt;
PEDIATRIC Multiple Sclerosis Cohort. Support of multi-center distributed processing project&amp;lt;br&amp;gt;&lt;br /&gt;
* Introduced Slicer 3.6 for the MS Lesion Assessment step performed at Mayo Clinic. Images are being transferred from image repository at BWH and automatically opened and arranged within Slicer GUI for reading.  This was replacement of Client GUI using MIPAV that stopped working on new computers at Mayo Clinic.&lt;br /&gt;
The images are being loaded via generated MRML Scenes same way as in PET/CT and AGING STUDY projects &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* August 22 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Preprocessing pipeline merge with SUV computations &amp;lt;br&amp;gt;&lt;br /&gt;
- QA for SUVs computation was performed by Wendy Plesniak for images with known uptake values. &amp;lt;br&amp;gt;&lt;br /&gt;
- Discovered that image cropping step (not related to automated registration pipeline and SUVs computing) smoothes the images by doing interpolation when used with default settings. Got suggestions from Steve Piper using Nearest-Neighbor interpolation (&amp;quot;no interpolation&amp;quot;) for a time being&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
- This is the new project candidate. Requested for the images with failed manual segmentation and/or segmentation with FreeSurfer. The EM Segmentation run showed most acceptable results on one of the problem images back in February &amp;lt;br&amp;gt;&lt;br /&gt;
- The workflow will be developed and deployed similar to PET/CT ROI Longitudinal study approach - all preprocessing steps will be done with Slicer modules, all runs will be performed on local end-user machines.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
 &lt;br /&gt;
&lt;br /&gt;
* August 15 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- First 5 cases with 3-4 time points preprocessed for SUVs computation&lt;br /&gt;
&lt;br /&gt;
* August 8 2010&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Testing of installation and operation at users' site (Performed by Wendy Plesniak)&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* July 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Delivered beta version of registration pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
- Prepared installation and user manuals &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* June 11, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Registration modules completed &amp;lt;br&amp;gt;&lt;br /&gt;
- Irregular cases registration problem solved (when whole body and brain only scans are mixed for a timepoint)&amp;lt;br&amp;gt;&lt;br /&gt;
- Live demo of case setup and registration workflow for end users. Real case with 4 timepoints used&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Coming week plans&amp;lt;br&amp;gt;&lt;br /&gt;
- Adjust workflow based on end users' feedback&amp;lt;br&amp;gt;&lt;br /&gt;
- Integration with SUVs computing for PET scans&amp;lt;br&amp;gt;&lt;br /&gt;
- GUI for workflows dispatching and data organizing&amp;lt;br&amp;gt;&lt;br /&gt;
- (TBD) Integration with 4D time series analysis Slicer module&amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
* May 28, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- Migration to the latest Slicer 3.6 release candidate &amp;lt;br&amp;gt;&lt;br /&gt;
- Added webservice for new registration module: BRAINSFit &amp;lt;br&amp;gt;&lt;br /&gt;
- Test runs for new patients with 4 timepoints' scans &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Plans for next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI &amp;lt;br&amp;gt;&lt;br /&gt;
- processing workflow demo for end user &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 21, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Pilot version of portable web services and automated workflow tested: &amp;lt;br&amp;gt;&lt;br /&gt;
Linux: workflow and visual review passed&amp;lt;br&amp;gt;&lt;br /&gt;
Stress test for 25 timepoints passed &amp;lt;br&amp;gt;&lt;br /&gt;
MAC OS: workflow passed, visual review failing when PET/CT images are loaded into GUI simultaneously (bug report submitted)&amp;lt;br&amp;gt;&lt;br /&gt;
Windows: need to adapt command line modules and workflow management system to sygwin environment&amp;lt;br&amp;gt;&lt;br /&gt;
Plans for next week: integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI&lt;br /&gt;
&lt;br /&gt;
* May 7, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Selected registration and resampling modules with more precise and stable outputs. &amp;lt;br&amp;gt;&lt;br /&gt;
Started building portable web services and automated workflow &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 30, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- manual walk through the processing steps: ROI cropping, registration/resampling, PET pharmaceutical DICOM data retention. &amp;lt;br&amp;gt;&lt;br /&gt;
- testing workflow and web services packages distribution to end-users' machines&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* April 23, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : testing various registration and re-sampling algorithms (work in progress)&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation: as of collaborators' request, run existing EM Segmentation workflow for older low resolution pseudo-T1 images. The EM Segmentation works for those images with manual sampling. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 16, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
  Social Cognition Study: started Cortical Thickness Measurement module build (bases on NA-MIC ARCTIC pipeline) &amp;lt;br&amp;gt;&lt;br /&gt;
  PET/CT ROI/Longitudinal Study Registration : Design specs, PET-to-CT images registration tests on training data. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 9, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. GUI update based on end-user experience.&amp;lt;br&amp;gt;&lt;br /&gt;
User request: automated label maps' volumes calculation (Currently possible from Slicer3 GUI)&amp;lt;br&amp;gt; &lt;br /&gt;
PET/CT ROI Project. Initial design specs discussion with end-users and co-developers&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure&lt;br /&gt;
Verification of segmentation workflow GUI: from registering new case to reviewing results&amp;lt;br&amp;gt;&lt;br /&gt;
Cross study test of segmentation workflow: MGH/MS Center data - success,  HIV Project data - some EM Segmentation scene tuning is needed &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*&lt;br /&gt;
* April 2, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. Segmentation workflow completed&amp;lt;br&amp;gt;&lt;br /&gt;
* Coming Week plans:&amp;lt;br&amp;gt;&lt;br /&gt;
- Document Segmentation Workflow. Follow up with end users &amp;lt;br&amp;gt;&lt;br /&gt;
- Start with Cortical Thickness and ROI-in-longitudinal studies workflows&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* March 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All essential processing and workflow interaction clients are ready.&amp;lt;br&amp;gt;&lt;br /&gt;
- Completed segmentation for 10 out of 50 patients. The remaining cases will be finalized upon manual lesion segmentation and QC verification of WM/GM/CSF and Deep GM segmentation's. &amp;lt;br&amp;gt;&lt;br /&gt;
- TODO next week: refine QC GUI and data tracking / progress monitoring schema. &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&amp;lt;br&amp;gt;&lt;br /&gt;
- New Slicer3 web services added: re-slicing with reference image volume, casting image scalar type &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
* March 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Segmentation maps Merging Services for GM/WM/CSF (Slicer EM Segemnter), Lesion (Slicer, Manual), and Deep GM (FreeSurfer)  &amp;lt;br&amp;gt;&lt;br /&gt;
- Deep GM segmentation pipeline adopted as optional service for Social Cognition Study (22 out of 50 cases processed) &amp;lt;br&amp;gt;&lt;br /&gt;
- (In progress) GUI client for Launching Segmentation results merging with optional Deep GM segmentation with FreeSurfer &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- Complete GUI Client for Segmentation result merging &amp;lt;br&amp;gt;&lt;br /&gt;
- Progress Monitoring services for entire Study processing: EM Segmenter Preprocessing, EM Segmentation, Lesion Segmentation (including human activities assignments), Deep GM segmentation, and results consolidation. &amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* March 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All 50 cases went through &amp;quot;basic&amp;quot; One-channel EM segmentation (GM/WM/CSF) &amp;lt;br&amp;gt;&lt;br /&gt;
- Basic pipeline start-up command line client created: user has two options - request brainmask extraction or provide with previously extracted brainmask for a given subject &amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison of GM/WN/CSF performed for Slicer EM Segmenter and FreeSurfer recon-all (used with default settings). &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmenter provides more accurate output &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmentation pipeline runs faster (40 minutes vs 12 hrs when no brainmask extraction requested) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO:&amp;lt;br&amp;gt;&lt;br /&gt;
- merging modules for automatic 1-channel EM segmentation and manual lesion segmentation &amp;lt;br&amp;gt;&lt;br /&gt;
- Emerge Cortical Thickness pipeline project: use NAC ARCTIC processing steps and modules &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Selected stable EM Segmentation scenario: White Matter, Gray Matter, and Cerebrospinal Fluid &amp;lt;br&amp;gt;&lt;br /&gt;
- First 16 cases are segmented for selected scenario. Nine more cases are preprocessed for EM Segmentation.&amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison to segmentation with FreeSurfer showed better accuracy for Slicer2 EMSegmenter &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure &amp;lt;br&amp;gt;&lt;br /&gt;
- Three prerpcocessed cases failed during volume ICC masking with in-house build utility. Evaluated switching to Slicer3 Mask and island removing modules.&amp;lt;br&amp;gt;&lt;br /&gt;
- Initial design specs discussion for cortical thickness measurement pipeline. ARCTIC pipeline selected. ARCTIC preprocessing steps signifficantly overlap with EM Segmentation preprocessing workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
  &lt;br /&gt;
* February 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: &amp;lt;br&amp;gt;&lt;br /&gt;
A) parameters tuning for EM Segmenter itself (work with EM Segmenter developer), template scenes creation &amp;lt;br&amp;gt;&lt;br /&gt;
B) update preprocessing pipeline - deep gray matter atlases included &amp;lt;br&amp;gt;&lt;br /&gt;
C) test and debug preprocesing pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
D) identified missing modules: atlas autocalibration for EM Segmentation scene, Island removal for ICC mask&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- Review currently deployed modules. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: reviewed firts seven subjects' outputs, added volume orientation module into pipeline (prevents ICBM atlas linear registration failures)&amp;lt;br&amp;gt;&lt;br /&gt;
- Fused ICC(brainmask) extraction module with EM Segmenter preprocessing. Three scenarious implemented: start with pre-extracted ICC mask (longitudinal studies case), run with ICC ectration, run with ICC extraction AND ICC correction before ICBM atlas preporcessing. &amp;lt;br&amp;gt;&lt;br /&gt;
- Completion of Human activities GUI (QC, ICC Correction) planned for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: Volume Orientation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: automated preprocessing pipeline for Slicer2 EM Segmenter test version deployed. Seven cases pre-processed.&lt;br /&gt;
- PET Quantitative measurements: Preliminary design specs discussion.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: BSplineRegistration (for non-linear registration), ResampleVolume2 (for atlases resampling based on image atlase templates registration). Local and Network runs are implemented, Cluster/GridWizard implementation pending.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Slicer EM Segmenter module: preprocessing design for Slicer2 EM Segmenter&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Adapting for Slicer2 EM Segmenter (mostly from pipelines and services for previous projects)&lt;br /&gt;
  -- Integration with FreeSurfer modules for bisafield correction, brainmask extraction, and linear registration of ICBM atlases&lt;br /&gt;
  -- Preprocessing updates for non-linear registration of ICBM atlases with Slicer2 (image re-orientation service designed)&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 29, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- EM Segmentaton pipeline: preprocessing results are being transferred to XNat (anonymized data, Central XNat) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Slicer EM Segmenter module: discussed agenda and scheduled a work meeting for Social Cognition Study image segmentation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Testing stage, 95% completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- SPL XNat server: verified data exchange via RESTfull web services.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 22, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Follow up with White Matter Lesion Segmenter and Scull Stripping Modules developers: Work in Progress&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Work in Progress, 60%+ completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Discussed SPINE image repository migration to XNat&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 15, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. &lt;br /&gt;
- Social Cognition Study: &lt;br /&gt;
Work-in-progress on intermediate (reconstruction) and results (resources) data storage at XNat.&lt;br /&gt;
&amp;lt;br&amp;gt;Reviewing and preparation more cases for EM Segmentor (Slicer 3.5) tuning.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* NA-MIC Project Week&lt;br /&gt;
Selecting candidate Slicer modules for other than Lesion EM Segmentation topics of Social Cognition study: Withe Matter Lesion Segmenter (UNC), Scull Stripping utility from UIOWA.&lt;br /&gt;
Reviewing issues of currently used Scull Stripping Slicer Extension and Slicer 3.5 EM Segmenter.&lt;br /&gt;
&amp;lt;br&amp;gt;XNat Data organizing training&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 1, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Preparation of Demo for NA-MIC work week: &lt;br /&gt;
- COPD Study. Added Remote pipepline start interface (represents real world scenario where Xnat repository, Processing modules and User are at different sites)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
- EM Segmentation. Added human activities steps to the workflow: ICC (brainmask) correction and EM Segmantation scena load per se.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 25, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Pilot workflow pipeline for EM Segmentation (all steps except user-activity step: ICC correction assignment and tracking)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 18, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Build and tested web services for EM Segmentation image preprocessing: DICOM-to-NRRD conversion, registration, skull stripping, image masking.&lt;br /&gt;
Started building workflow pipeline (subject to finish first version next week)&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Started Collecting Library of Slicer Build number vs. functional modules and extensions.&lt;br /&gt;
Plan for NAMIC project week: scheduled meetings for XNat data customization, Skull-stripping modules tuning, identified Social Cognition study cases that fail EM Segmentation processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 11, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Updating and verification of EM Segmentation Scenario&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Projects:ARRA:SlicerWF:UseCaseScenarios#Usecase_MS_lesion_Assessment&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Familiarizing with Slicer3.4/5 Modules required for implementation of EM Segmentation Scenario. Participation in debugging and/or usage tuning of Dicom Conversion, Registration, Skull Stripping, Masking, and Image Casting modules. &lt;br /&gt;
&lt;br /&gt;
* December 4, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Slicer3.4's EM Segmentation and Visual QC as part of image processing pipeline for Social Cognition Study for MS Patients.&lt;br /&gt;
Project emerged. EM Segmentation template creation debugged.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
Emphysema Measurements (COPD Study) - workflow stability and scalability test.&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 27, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Emphysema Measurements (COPD Study).&lt;br /&gt;
Added compensation for long running calculations and time-outs to the main computing pipeline.&lt;br /&gt;
Visual QC (work in progress)&lt;br /&gt;
** Infrastructure&lt;br /&gt;
XNat data structure customization, metadata storage, results consolidation: new feature request list creation (work in progress)&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 13, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
*** Pilot system for whole processing cycle for Emphysema Measurements (COPD Study) including the following:&lt;br /&gt;
Web query for CT session file list download&lt;br /&gt;
Pilot user interface for submitting the file list and starting processing pipeline&lt;br /&gt;
Notification about processing steps and failures&lt;br /&gt;
Upload results to XNat repository (at this stage results are uploaded into same folder where original scans are(*))&lt;br /&gt;
*** Immediate Plans&lt;br /&gt;
Complete Visual QC module&lt;br /&gt;
Design and implement meta-data transfer to XNat (including processing details and MRML files for loading images into the 3D Slicer)&lt;br /&gt;
&lt;br /&gt;
(*)Customization of results storage&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 6, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Tuned and debugged multiple subjects processing for: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat.&lt;br /&gt;
***Started working on quality control embedding into the above scenario. Plan to complete and video-record demo next week.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***Published general Product Integration scenario flow chart to collaborators' community. Discussion is open and in progress&lt;br /&gt;
&lt;br /&gt;
* October 30, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Piloted and tested the sequence: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat(1).&lt;br /&gt;
***Performance test of overall cycle: data transfer from remote serve is a bottleneck as expected&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data browsing features reviewed.&lt;br /&gt;
(1) Not automated yet&lt;br /&gt;
* October 23, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Defined COPD processing scenario with interoperability between Xnat, 3D Slicer Command Modules, Workflow, and Gridwizard Enterprise.&lt;br /&gt;
***Pilot version of Emphysema Measurements workflow pipeline deployed.&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data transfer features reviewed. Use account at XNat Central during learning curve.&lt;br /&gt;
***Feasibility test of 3D Slicer fiducials module for ROI highlights during QC and manual image processing activities. &lt;br /&gt;
* October 16, 2009&lt;br /&gt;
**Lung CT Scans Processing. Pilot project emerged. GenerateEmphysemaMeasurements module deployed as a webservice that submits jobs to computational cluster.&lt;br /&gt;
**EM Segmentation. Familiarized with GUI steps. Started working on automation steps outlining&lt;br /&gt;
**3D Slicer and XNat interaction. Got an overview from Wendy Plesniak.&lt;br /&gt;
* October 1 - 7, 2009&lt;br /&gt;
**Selected two first priority Projects: EM Segmentation of brain MRI images; Lung CT Scans Processing (COPD Study)&lt;br /&gt;
**Got initial outline of user requirements and design specs&lt;/div&gt;</summary>
		<author><name>Azaitsev</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=File:RussianCardiologyCenterCARMA2011.ppt&amp;diff=70188</id>
		<title>File:RussianCardiologyCenterCARMA2011.ppt</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=File:RussianCardiologyCenterCARMA2011.ppt&amp;diff=70188"/>
		<updated>2011-08-06T19:51:21Z</updated>

		<summary type="html">&lt;p&gt;Azaitsev: Slicer Demo at Russian Cardiological Research Center 2011&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Slicer Demo at Russian Cardiological Research Center 2011&lt;/div&gt;</summary>
		<author><name>Azaitsev</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=70187</id>
		<title>Projects:ARRA:SlicerWF</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=70187"/>
		<updated>2011-08-06T19:39:39Z</updated>

		<summary type="html">&lt;p&gt;Azaitsev: /* Progress */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Projects:ARRASuplements|Back to Slicer ARRA home page]]&lt;br /&gt;
= Aim =&lt;br /&gt;
Supplement 3D Slicer and Extensible Neuroimaging Archive Toolkit (XNAT) with workflow management system. Provide integration and interoperability between 3D Slicer, XNAT Services and 3-rd party image processing applications and high performance computing systems. Implement it as within currently developed Structural Planning and Implementation in Neurological Exploration (SPINE) System.&lt;br /&gt;
&lt;br /&gt;
= SPINE Project Documentation =&lt;br /&gt;
[http://cni.bwh.harvard.edu/projects/spine/index.html SPINE Docs]&lt;br /&gt;
&lt;br /&gt;
= Presentations =&lt;br /&gt;
* Segmentation Workflow. PECS University Social Cognition Study.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:SlicerWF_NAC_PECS_Workflow.pdf]]&lt;br /&gt;
* EAB10_ARRA Annual Progress Report Slides.&amp;lt;br&amp;gt;&lt;br /&gt;
[[media:EAB10_ARRA_WF_2011_Zaitsev.ppt | Service Oriented Solutions for 3D Slicer. EAB10_ARRA_WF_2011. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:EAB10_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:NAMIC_ARRA_WF_2011_Zaitsev.ppt  | NAMIC Annual Report 04/2010-03/2011. NAMIC_ARRA_WF_2011_Zaitsev. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:NAMIC_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:Slicer_WF_Slicer4CARMAWorkflow.ppt  | CARMA Workflow. Cardiac Ablation Followup. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:Slicer_WF_Slicer4CARMAWorkflow.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* CARMA Project Beta release Demo Location: http://cni29.bwh.harvard.edu/SlicerWFDemo/index.php&lt;br /&gt;
&lt;br /&gt;
* Segmentation Workflows: Screenshots, scans' and study description : [[File:SlicerWF_EMSegmentProjectsReview.zip]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
= All Hands Meeting Pages =&lt;br /&gt;
* Salt Lake City 2011 Winter [http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA SLC_2011_WorkFlow]&lt;br /&gt;
* MIT 2010 Summer [http://wiki.na-mic.org/Wiki/index.php/Summer_project_week_2010_Workflows_SOA MIT_2010_WorkFlow]&lt;br /&gt;
&lt;br /&gt;
= Research Plan =&lt;br /&gt;
*Create a stand-alone SPINE desktop agent with fully functional data exchange and communication mechanisms towards 3D Slicer and XNAT.&lt;br /&gt;
*Develop Service Oriented Architecture (SOA) SPINE System that will include 3D Slicer image processing modules deployed as web services as well as a workflow management system to orchestrate interaction between 3D Slicer, XNAT, and 3-rd party tools.&lt;br /&gt;
*Implement two-way control and communications between 3D Slicer and SPINE modules.&lt;br /&gt;
*Adapt SPINE System for cluster and grid computing scenarios.&lt;br /&gt;
*Provide with workflow and 3D Slicer web service wrappers editing tools.&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:UseCaseScenarios| Use Case scenarios]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PETCTWorkflow| PETCTWorkflow]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:AgingStudySegmentation| AgingStudySegmentation]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:TwoTensorTractography| TwoTensorTractography]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:LongitudinalMultimodalityRegistrationSuite| LongitudinalMultimodalityRegistrationSuite]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:MigrationJavaClients2QT| MigrationJavaClients2QT]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PediatricMSSegmentation| PediatricMSSegmentation]]&lt;br /&gt;
*[[DBP3:Utah:RegSegPipeline| MRI-based study and treatment of atrial fibrillation]]&lt;br /&gt;
&lt;br /&gt;
= Application Server / Workflow Engine Downloads =&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:WFEngineDownloads| Download Links]]&lt;br /&gt;
&lt;br /&gt;
=Key Personnel=&lt;br /&gt;
* Charles Gutmann, MD., 4%,  9-17-2009 through 9-16-2011&lt;br /&gt;
* Alexander Zaitsev, Ph.D., 75%, 9-17-2009 through 9-16-2011 &lt;br /&gt;
&lt;br /&gt;
=Annual Progress Statements =&lt;br /&gt;
'''2010-11''' &amp;lt;br&amp;gt;&lt;br /&gt;
The  April 2011 – March 2011 period was devoted on developing portable workflow solutions that can be deployed on end-users' workstations or notebooks with minimal or no system administration activities. This is in contrast to the server-side deployment. The following scenarios had been deployed and used for actual projects that require the following types of workflows: PET/CT registration and computation of biomarker driven brain physiological activities, Brain MRI Images segmentation,  MRI and MRI Angiography images pre-processing for cardiac ablation outcome estimation. Some  workflows (like EM Segmentation) had been utilizing various scenarios, some research projects  (like evaluation of chemotherapy outcome) require two types of workflows to assess physiological and structural changes. Starting from the 4th Quarter of 2011, the migration project had been emerged in order to embed Workflow GUIs into newly developed Slicer4 Suite. The existing rich client Java GUI applications are being re-written as C++/QT Sliceletts units, new modules (such as cardiac ablation project support) are had been written from scratch. The latter are being deployed from the Slicer4 GUI and act at a liaison between Slicer4 and Application Server containing  workflow and Slicer modules deployed as services. The feedback from the end users indicates that Workflow approach for the complex processing improves productivity, aids to the processing standardization and contributes to the overall experience using 3D Slicer&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
=Quarterly Progress=&lt;br /&gt;
&lt;br /&gt;
* '''2d Qtr, 2011''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study: Second release deployed. &lt;br /&gt;
*** End-users completed the first Project and currently analyzing SUV values and clinical data&lt;br /&gt;
*** New features added: Human Brain Hemispheres segmentation, Scull-stripping for total SUV counts calculation, Flexibility of custom designed label look-up table usage (users can define ROI notation according to the Project needs)&lt;br /&gt;
&lt;br /&gt;
** Left Atrium Ablation Assessment (CARMA Project)&lt;br /&gt;
*** Completed workflow pipeline for automated pre-processing and manual intervention&lt;br /&gt;
*** Developed front-end GUI for the CARMA Project support in Slicer4.&lt;br /&gt;
*** Run the workflow with the end users during NAMIC Project Week&lt;br /&gt;
*** Evaluated feasibility of left atrium wall and post-ablation scar segmentation using Robust Statistical Segmentation (RSS). Identified necessary processing controls with RSS module designers&lt;br /&gt;
&lt;br /&gt;
** Multiple Sclerosis CLIMB Study&lt;br /&gt;
*** Reprocessing for lesion segmentation&lt;br /&gt;
*** Developed Web-based (Java EE 6) application for submitting cases to the workflows for EM Segmentation of MPRAGE and registration to PD/T2/FLAIR images (60% completion)&lt;br /&gt;
&lt;br /&gt;
** EM Segmentation: &lt;br /&gt;
*** Upgraded EM Segmentation services to Slicer 3.6.4&lt;br /&gt;
*** Added brain hemispheres segmentation module to the workflows (used for PET/CT Longitudinal study)&lt;br /&gt;
*** Work with EM Segmenter module developers on building pipelines for white matter lesion segmentation (work in progress)&lt;br /&gt;
&lt;br /&gt;
** Plans for the 3rd quarter&lt;br /&gt;
*** Migrate CARMA Project workflow to end-users&lt;br /&gt;
*** Packaging of Slicer4 Workflow modules and Slicer4 custom build distribution &lt;br /&gt;
*** Completion of Web-base segmentation and registration suite&lt;br /&gt;
*** Users and Developers Documentation&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* NAMIC Annual Progress Slides (April 2010 - March 2011):&lt;br /&gt;
&lt;br /&gt;
* '''1st Qtr, 2011''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study: Second release is under testing by end-users. &lt;br /&gt;
*** Added MRI registration to aid ROI drawing on PET scans&lt;br /&gt;
*** Improved SUV results reporting and added flexibility to update ROI lookup table&lt;br /&gt;
*** Automated EM Segmentation of MRI images for computing SUVs for white matter, CSF, and whole brain (80% completion)&lt;br /&gt;
*** Integration with SPECTRE scull stripping module (70% completion) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** EM Segmentation: Automated WF Pipelines are created &amp;lt;br&amp;gt;&lt;br /&gt;
*** Flexible atlas selection (Pediatric, etc) feature added&lt;br /&gt;
*** Workflows implemented for EM Segmenter 3.6.2 and 3.6.3 (1st Qtr 2011 release)&lt;br /&gt;
&lt;br /&gt;
** Cardiac ablation results follow-up: Workflow for registration and ROI selection of cardiac MRI and MR Angiography &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Wrokflow and Web Services for prospective DTI tractography modules (currently written as Matlab modules at PNL) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Web Services for SPECTRE Scull stripping module&lt;br /&gt;
*** Accuracy and performance tuning&lt;br /&gt;
*** 50% completion&lt;br /&gt;
&lt;br /&gt;
** Migration Front End GUI to Slicer4/QT:&lt;br /&gt;
*** EM Segmentation&lt;br /&gt;
*** Cardiac Ablation Study&lt;br /&gt;
&lt;br /&gt;
** DICOM Uploader and Desktop Browser for XNat Image repository (alpha version - tested for MGH MS Center studies, proposed to use with MI2B2 Clients and Services)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''4th Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study and EM Segmentation for Aging Study are deployed at end-user sites and actively used for research. &lt;br /&gt;
** Adopted EM Segmentation preprocessing pipeline for HIV Study: high resolution SPGR images, integration with FreeSurfer brainmask extraction outputs; integration of Slicer SPECTRE module for brainmask extraction is in progress.&lt;br /&gt;
** The following post-release upgrades had been implemented based on end-user feedback: Application Server basic controls are performed from Rich Client GUI as alternative to traditional IT administration activities. The controls are implemented on point-and-click bases and include web services and workflow application deployment and upgrades, application server start and stop as well as warning end user when the server is not accepting request.&lt;br /&gt;
** Added DICOM downloads and results uploads of PET/CT pipelines from and to XNat Repository&lt;br /&gt;
** Created Services and Workflow for Matlab Prototypes modules. Case Study: tractography for DTI images&lt;br /&gt;
** Extended XNAT integration services:&lt;br /&gt;
*** Browsing capabilities of XNat data repository from the Workflow Applications&lt;br /&gt;
*** Improved DICOM upload and download performance&lt;br /&gt;
*** Added Metadata organizing services for uploaded DICOM images: header data extraction, image snapshots creation. &lt;br /&gt;
** Started project for Rich Client GUI migration from Java desktop application to build into SLicer4 QT modules. This affects mostly front-end GUI and has the following approaches: distribution with the Slicer4, end-user will select desired workflow application from Slicer4 menu while QT-written modules provide with the same functionality as Java Rich Clients. Case Study for the Migration process: registration suite for longitudinal studies that include multi-modality images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* '''3d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Concentrated on building downloadable workflow applications that could run both in desktop (new) and server environment, and that require minimum IT administrative resources. The desktop deployment is in compliance with Slicer3 general deployment concept.&lt;br /&gt;
*** The following use case scenario had been chosen: PET/CT image processing for longitudinal studies, EM Segmentation for longitudinal Aging Study.&lt;br /&gt;
** Released workflow application for PET/CT image processing for longitudinal studies. Provided end users with training and documentation.&lt;br /&gt;
*** The PET/CT processing workflow was designed to be a general application used whenever both structural patterns and metabolic activities are within the research scope. &lt;br /&gt;
*** The desktop version is tuned to use minimal computer resources, so the automates processing instances do not interfere with human activities. Automated activities may include, for example, registration and PET scan's standard uptake values computing, and manual human activities may include image cropping, quality control, and labeling voxels of interest.&lt;br /&gt;
** Core services and EM Segmentation preprocessing workflow was build for retrospective Aging Study. Tuned the Slicer3 webservices for processing low grade images acquired in mid 90s. Entire workflow is implemented with Slicer3 only modules and can be deployed locally and on the servers. Usage of Service Oriented Architecture (SOA) as a core technological approach allowed reusing most of the web services that had been build for PET/CT project. &lt;br /&gt;
** Continued embedding Slicer3 application and modules into previously released processing pipelines: replaced MIPAV with Slicer3 GUI for lesion assessment step in the multi-center Pediatric MS Cohort image processing &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''2d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Completed Social Cognition Workflow Implementation. This includes EM Segmetnation pre- and post-processing pipelines, data tracking, and integration with 3d party image processing utilities, as well as processing results acquired manually with Slicer GUI.  &lt;br /&gt;
** Multi-modality image registration and ROI selection/alignment workflow for longitudinal studies. &lt;br /&gt;
*** Use case: PET/CT image processing for longitudinal studies. &lt;br /&gt;
*** Build portable library of Slicer modules as web services and workflow that are deployed and run on a end-users' worksatations without utilization of SPL and other servers. The web services include novel Slicer3 modules, such as BRAINSFit and BRAINSResamle &lt;br /&gt;
*** Started working with Slicer3 developers on Slicer 3.8 GUI wizard to communicate with workflow instances.&lt;br /&gt;
** Participated at NA-MIC Summer 2010 Project Week: [[Summer_project_week_2010_Workflows_SOA]]&lt;br /&gt;
&lt;br /&gt;
=Progress=&lt;br /&gt;
* August 1, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA Project&lt;br /&gt;
* Documentation (Work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation&lt;br /&gt;
* Stress-test of online segmentation requests suite for  [http://www.slicer.org/slicerWiki/index.php/EMSegmenter-Tasks#Additional_Use_Cases CLIMB Study](for BWH MS Center)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* July 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA Project&lt;br /&gt;
* Documentation (Work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation&lt;br /&gt;
* Work on alpha-release of online submission of segmentation requests (for BWH MS Center)&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* July 22, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
Vacation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* July 8, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
3D Slicer in General and CARMA Project&lt;br /&gt;
* Presentation and life demo at Cardiology Research Center (Moscow, Russia)&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* July 1, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA V1.0&lt;br /&gt;
* Migration to new QT building environment (Mac 10 Snow Leopard)&lt;br /&gt;
* Comparing preprocessing workflow results with published in literature data (our module produces better alignment)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*June 24, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
Project Week:&lt;br /&gt;
* Testing RSS module for left atrial wall scar segmentation&lt;br /&gt;
* Testing EM Segmenter for lesion detection on PD (requested by end-users) and FLAIR images&lt;br /&gt;
&lt;br /&gt;
EM Segmentation &lt;br /&gt;
* Web-based segmentation and registration module for MS Center. Goal: facilitate 3D SLicer modules for the cases that could not be processed with in-house build DTS+ algorithm&lt;br /&gt;
* Pipeline: Segment MPGR or T1 (user's choice), Register MPGR to PD/T2, Resample Segmentation Map to PD/T2. Completion: 60-70%.&lt;br /&gt;
* The rest will be done manually or via lesion segmentation with EM Segmenter.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* June 17, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
Preparation for Project Week&lt;br /&gt;
&lt;br /&gt;
* June 10, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
CARMA V.1.0&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code completed and tested&lt;br /&gt;
* Packaging as extension is pending (Subject for Summer 2011 Project week)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Debugging consolidation results issue(SUVs for manual and automated segmentation) &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* June 3, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Deployed on end-user's machine&lt;br /&gt;
* TODO next week: fix SUV results consolidation issue (when MRI segmented ROI got SUV computed for some subjects, only those subjects' SUVs are being added into consolidated report. &amp;quot;Raw&amp;quot; SUV values per subject are generated as expected)  &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 27, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Ready for deployment. New Features: hemispheres EM Segmentation, automated ICC/brainmask extraction using EM Segmenter, fixed controls for MRI conversion and registration&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 20, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General / PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Hemispheres EM Segmentation - adjusted for required label lookup table&lt;br /&gt;
* Use cases added for EM Segmenter General Project: http://www.slicer.org/slicerWiki/index.php/EMSegmenter-Tasks#EMSegmenter_use_cases&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SPECTRE Scull Stripping&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* The new version to be tested on coming week (After PETCT MRI processing migrated to Hemispheres scenario )&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* May 13, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General / PETCT V1.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Hemispheres EM Segmentation - technically works with labal values hardcoded in Slicer EM Segmenter - need to add manual label value edition step&lt;br /&gt;
* PETCT WF Cut for Java GUI (Pending Hemispheres label update completion). Next release will be in QT4.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* May 6, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (QA of EM Segmenter module, work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* April 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Open Discussion for Packaging WF QT Modules as Slicer4 extensions (waiting for SOPs)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review supported projects http://wiki.na-mic.org/Wiki/index.php/File:SlicerWF_EMSegmentProjectsReview.zip &lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (required by Study)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Slicer Modules General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Standardizing Crop Volumes Output (with A. Fedorov's module). Review for required updates of existing product (PET/CT, CARMA)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Open Discussion for Packaging WF QT Modules as Slicer4 extensions (waiting for SOPs)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review supported projects http://wiki.na-mic.org/Wiki/index.php/File:SlicerWF_EMSegmentProjectsReview.zip &lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (required by Study)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Slicer Modules General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Standardizing Crop Volumes Output (with A. Fedorov's module)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 22, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Beta release ready. Demo Location: http://cni29.bwh.harvard.edu/SlicerWFDemo/index.php&lt;br /&gt;
* TODO: Tutorial. Original inputs copy/renaming&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 15, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Adding App server auto-config features&lt;br /&gt;
* Finalizing the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 08, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Second release beta build tested on cosutmer side &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review registration quality (with Dr. Meier). Angiography images' Resampling tuned. &lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 01, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the second release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
XNat Integration&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* (Java) GUI for Project Browsing and DICOM Series Upload. Post-upload DICOM processing tested and debugged&amp;lt;br&amp;gt;&lt;br /&gt;
* Ready for integration with mi2b2 client.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Migrated to Latest Slicer 3.6.3 stable release: only the Input scene had to be updated, the API remained the same&lt;br /&gt;
* Tested EM Segmenter with CMTK4Slicer extension - processing takes to much time on Linux_64bit machine, rolled back to BRAINSFit registration. When used on Mac OS X build, the Slicer could not start (bug report 1126).&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SPECTRE Scull Stripping:&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Testes for various use cases: the module is extremely sensitive to T1 MRI quality (does not work for most MRIs from PET/CT project&lt;br /&gt;
* TODO next week: check for FLAIR images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Slicer4 QT GUI and Cropping activity in progress.&amp;lt;br&amp;gt;&lt;br /&gt;
* Tried direct MRA to MRA registration option: resampling with LMRI registration transforms works better.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Extra VOI labels revised&lt;br /&gt;
* Debugging of SUV results' renormalization step&lt;br /&gt;
* TODO: ICC extraction / whole brain total uptake computing; EM Segmentation for R_WM, L_WM SUV computing and BPH estimation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SCULL STRIPPING/SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Installed and tested CLI option on Linux_64bit platform&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Workflow interruption before BSPline registraton: BPEL Module completed. Slicer4 QT GUI and Cropping activity in prorgess.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Implemented and Tested with end-users proposed changes: denormalization of SUV results, adding more VOI labels, added FLAIR MRI in addition to T1s for VOI drawing&lt;br /&gt;
* Tested manual ICC extraction using PET scans: works satisfactory with island removal and cropping followed by threshold level labeling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4&lt;br /&gt;
* Change proposed: interrupt workflow after affine registration and have user crop the VOI. This is to prevent excessive deformations for BSpline registration and resampling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4. User has option to choose the atlas that fits better for the given subject (NOTE: hardcoding must be rewritten for atlas linking)&lt;br /&gt;
* PETCT test - the problem is that T1s are low resolution and with contrast. Proposed using T1s without contrast&lt;br /&gt;
* PETCT change request: users wants to compute SUV for entire ICC. Had demo how to segment brainmask/ICC using PET scan. The derived brainmask label can be used for SUV computation.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - cmpleted&lt;br /&gt;
* Sample cases run - excessive deformation after BSpline registration hase&lt;br /&gt;
* Next week plan - pull tuning controls to front-end of pipeline API, start working of QT module for CARMA registration&lt;br /&gt;
* May consider other than BRAINSFit registration modules&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Design plan for change request: more VOI labels, add FLAIR in addition to T1 for VOI drawing, T1s segmentation&lt;br /&gt;
* Tested segmentation for sample cases - artifacts from poor quality MRIs lead to exclusion of parts of ICC from segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Completed troubleshooting of EMSegmenter module calling from Java (need TCL libs to be pulled from Slicer environment)&lt;br /&gt;
* Tested EMSegmenter autoruns for HIV and Pediatric MS patiens. Work as expected, subject to improvement of PED MS case segmentation by building better skull/neck/air atalses&lt;br /&gt;
* Suggested usage of two subsets of atalases: with and without neck. The Subject MRIs have to be cropped accordingly or best fit atlas has to be selected&lt;br /&gt;
* Made no-neck cropped atlas collection for default EMSegmenter scenario&lt;br /&gt;
* Tested with PET/CT study MRI cases - see above &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - in progress&lt;br /&gt;
* Next week goal - have back end processing ready&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Longitudinal Study&lt;br /&gt;
* Added MRI registration to the pipeline&lt;br /&gt;
* Troubleshooting of complex XML schema issues on Linux machines (some modules working on MAC do not work on Linux). As a workaround - did not include MRI convert and register part into base BPEL module. Used separate services (transparent for end-user)&lt;br /&gt;
* TODO next week for change request completion: explicit pixel type casting for MRI in BRAINSFit, VOI MRML scene update (currently MRI added on top of schema)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* February 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipeline for Pediatric MRI. Same scenario as for HIV Project, icbm pediatric atlases (Completed, verified)&lt;br /&gt;
* Collected NIH healthy brain development atlases: various age ranges from 4.5 to 18 yo. Converted to Slicer readable format &lt;br /&gt;
* Work on web services for the new automated EM Segmenter module (release Nov 10 - current). Verified task completion both for adult and pediatric images. Discussed tuning parameters for work load balance on workstations.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Started working on MRI registration to the reference CT scans. &lt;br /&gt;
* Design specs for optional White Matter segmentation for SUV computing.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* February 4, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipelines for Pediatric MRI (in progress)&lt;br /&gt;
* Adapting Pediatric T1 atlases for &amp;quot;Human Brain&amp;quot; build-in EM Segmentation wizard (in progress)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 28, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Verifying EM Segmenter module for latest builds and HIV/PED MS Studies (report pending)&lt;br /&gt;
* Work with SPECTRE module developers with pediatric MRI brainmask extraction&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* January 21, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Compiling plan for WF FrontEnd GUI migration to Slicer4/QT Widgets&lt;br /&gt;
* Preparing for annual progress report&lt;br /&gt;
&lt;br /&gt;
* January 14, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI: Integrated into the Slicer4 as Slicelet (or thin Client)&lt;br /&gt;
* Participation at AHM-2011, discussing integration of SPECTRE module and updated approach to EM-Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA&lt;br /&gt;
&lt;br /&gt;
* January 7, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* HIV project workflow delivered. Major additions relate to user convenience: &lt;br /&gt;
- Project-specific parameter settings, importing T1s and brainmasks from FreeSurfer outputs with conversion to NIFTI, resampling brainmask to original scans and automatied subject addition.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Follow up with end user: need to add MRI scans, if available, addition and registration to CT in order to ease VOI drawings.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
 &lt;br /&gt;
* December 31, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Follow-up with user Experience for AGING Study Segmentation (Positive feedback)&lt;br /&gt;
* Target date for HIV project delivery - next week&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Self-training for QT widget development&amp;lt;br&amp;gt;&lt;br /&gt;
* Outlined Workflow Rich Clients migration strategy from Java to QT/Slicer4:&amp;lt;br&amp;gt;&lt;br /&gt;
** Use Java Stubs (similar to SPECTRE integration) or file binding for envocation of workflow pipelines. (See SOAP remark below)&lt;br /&gt;
** Direct Web Servisec calls must be wrapped into REST protocol. The reason: NON-commerchial QT kit does not include SOAP protocol for web servises.&lt;br /&gt;
** The GUI will be implemented as page widget or QT dialog GUI forms called from within Slicer4.&lt;br /&gt;
** Communications between Slicer4 and WF GUI will be set via child-parent and signal-slot relations&lt;br /&gt;
* Worked on a Prototype for Basic EM Segmentation QT widget (70% complete). Will work on integrtion with SLicer4 during the AHM-2010&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
XNAT Integration&lt;br /&gt;
* Debugged XNAT RESTFul API usage for uplaoding DICOM series followed by header data extraction and image snapshots creation&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Added compensation for failed atlas registration (subject for old poor quality pseudo-T1 images): blank probability maps are created in case of failure.&lt;br /&gt;
* Data preparation module for FreeSurfer data import near completion. Expected time for deployment at end-users workstations - first week of January&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Discussed strategy for EM Segmentation pipeline solutions collection (K. Pohl, R. Kikinis)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* RE-using the same core workflow as for 1-channel EM Segmentation of AGING STUDY cases&lt;br /&gt;
* Added data input preparation module: ICC label mask preparation and skull-stripping based on FreeSurfer brainmask output volume.&lt;br /&gt;
* Two-channel EM segmentation pipeline (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE / GENERAL Development &amp;lt;br&amp;gt;&lt;br /&gt;
* Worked on plans for migrating fro rich workflow Java clients to embedded workflow windows inside the Slicer.&amp;lt;br&amp;gt;&lt;br /&gt;
The embedded workflow management clients are to be implemented with QT/PyQT toolkits&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
INTEGRATION WITH XNAT:&amp;lt;br&amp;gt;&lt;br /&gt;
* Automated DICOM series upload with triggering DICOM headers parsing at XNat site (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress. &lt;br /&gt;
- Results upload to XNat (Completed) &amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat based on user's input (Project + Subject + PET or CT session / scan) (Completed)&amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat - perfomance boosting solution for downloads found , web services services are created, relinking for the client side in progress &amp;lt;br&amp;gt;&lt;br /&gt;
- Xnat querying for subjects and automated subject addition into the workflow (In Progress) &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-segmentation module added for auto correction of segmentation results. Particularly - relabeling CSF voxels segmented as Air inside the intracranial cavity. This was requested by end-users after processing images with zero-signals in CSF voxels &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting automated dual-echo DICOM images conversion and split into two NRRD volumes&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT / EM Segmentation pipeline:&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting memory allocation issues for scull-stripping module SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
COPD Project:&amp;lt;br&amp;gt;&lt;br /&gt;
* Benchmark test for accelerated DICOM downloads from XNat (remoote XNat Central server): we can handle at least 6 cases (4 CT scans in each) per hour, which is compatible with current workload quotes on SPL cluster processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* December 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Deployed Version 1. &amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Test project chosen as a closest match to registration scenario: Pediatric MS Cases from MGH - requires periodic image preview for different &lt;br /&gt;
modalities taken from vaious time points. Label maps for VOIs resampling is also required.&lt;br /&gt;
&lt;br /&gt;
* November 26, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user. Version 1 is complete&amp;lt;br&amp;gt;&lt;br /&gt;
* Started working on integration with XNat&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on input data organizing modules&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 19, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user (70% done)&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Universal Registration Workflow for Longitudinal Studies - design specs in progress&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 12, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Minor tuning to EM Segmentation template as of users' feedback&lt;br /&gt;
* Users started using the workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed input data conversion from Genesis to Slicer native or NIFTI format. Our help may be needed in input data organizing.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Tuned application according to co-laborators (PNL) needs&amp;lt;br&amp;gt;&lt;br /&gt;
* The webservices and BPEL workflow application are tested ready to accept computation requests from PNL case tracking system &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Discussed Universal Registration Workflow for Longitudinal Studies&lt;br /&gt;
* Started the thread about possible cooperation with Children hospital's image processing pipelines and integration with Xnat &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 5, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Webservices and workflow pilot project created and deployed on Psychiatry Neuroimaging Laboratory subnet &amp;lt;br&amp;gt;&lt;br /&gt;
* The V.1.0 deployment is scheduled for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 29, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Most of functionality is completed. Some volume statistics post processing is pending&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL EM SEGMENTATION Pipeline: &amp;lt;br&amp;gt;&lt;br /&gt;
* The SPECTRE scull stripping module. Started integration into EMS workflow. Made some test runs from Slicer GUI&amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Identified as a candidate for Workflow Application&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 22, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* All back-end functionality are implemented&amp;lt;br&amp;gt;&lt;br /&gt;
* EM Segmentation scene usability is confirmed by end-user&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for next week: add Label Statistics computation for CSF/Brain/ICC &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 15, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* The latest (October) builds of Slicer 3.6.2 produced acceptable results. This was verified by the target users. The EM Segmentation will be performed on Slicer 3.6.2 or later&amp;lt;br&amp;gt;&lt;br /&gt;
* The new Web services had been created and added to the pipeline as optional processing steps: Biasfield correction (implement novel N2ITKBiasFieldCorrection module) and Volume's scalar datatype casting (as workaround for Biasfield correction module not preserving image scalar datatype - the bug is filed) &amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed the Front-End GUI design with target users. The design pattern is taken from the PETCT project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 8, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-deployment support. Tuned CT registration as of user's feedback.&lt;br /&gt;
* Adapting to the Single Slicer build: Slicer 3.6.2. Found label duplicates in the label lookup table - will ask user if it's tolerable. Waiting for the Slicer 3.6.2 build that contains all required modules. Rolling back label tag appending code for SUVs - the latest Slicer build appends the tags.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Resumed development. The priorities are set for usage of Slicer 3.6.2 - subject for EM Segmentation scene tuning. Continued coding for Scene creation for Slicer 2.8 - as a backup option for ongoing research project.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 1, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized V1.0 release based on end-user feedback: updates relate mostly to error proofing and SUV values representation&lt;br /&gt;
* Post-deployment support. Users pre-processed first set of patients &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* September 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* System deployed and tested at End Users' site.&amp;lt;br&amp;gt;Users are trained to perform all tasks required by the workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
* Got positive feedback with suggestions on Slicer Scenes' layouts improvement and PET scans' SUV (standard uptake values) results display&lt;br /&gt;
* Two distribution packages are assembled: Lunix and MAC OS versions. The difference in two packages is in specific Slicer3.6/3.7 builds - subject to Slicer Linux builds debugging.&amp;lt;br&amp;gt; As a workaround for Linux deployment - multiple Slicer builds are used to perform various tasks (registration, opening editing scenes in Slicer, SUV computing)&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for coming week - finalize V1.0 release based on end-user feedback&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Embedded SUV computations into the workflow (as system calls - will be translated into web service later)&amp;lt;br&amp;gt;&lt;br /&gt;
* Pre-release demo for end users.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Create and debug EM Segmenter scenes template for Slicer 3.6 and 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* September 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation - workflow pipeline and deployment verified&amp;lt;br&amp;gt;&lt;br /&gt;
* Tested EM Segmentation scenes within Slicer 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
* Started migration of EM Segmentation to Slicer 3.6. Discovered issues had been reported to EM Segmenter module designers &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* August 29 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation completed. Preprocessing Pipleine completed 80% (subject for input registration parameters tuning) &amp;lt;br&amp;gt;&lt;br /&gt;
* Most webservices (for registration and resampling steps) had been taken and re-used from PET/CT ROI/Longitudinal Study - showing the advantage of service-oriented software design and deployment.&lt;br /&gt;
* Continued on distribution and deployment of the service/workflow applications: on PET/CT and AGING STUDY projects.&lt;br /&gt;
&lt;br /&gt;
PEDIATRIC Multiple Sclerosis Cohort. Support of multi-center distributed processing project&amp;lt;br&amp;gt;&lt;br /&gt;
* Introduced Slicer 3.6 for the MS Lesion Assessment step performed at Mayo Clinic. Images are being transferred from image repository at BWH and automatically opened and arranged within Slicer GUI for reading.  This was replacement of Client GUI using MIPAV that stopped working on new computers at Mayo Clinic.&lt;br /&gt;
The images are being loaded via generated MRML Scenes same way as in PET/CT and AGING STUDY projects &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* August 22 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Preprocessing pipeline merge with SUV computations &amp;lt;br&amp;gt;&lt;br /&gt;
- QA for SUVs computation was performed by Wendy Plesniak for images with known uptake values. &amp;lt;br&amp;gt;&lt;br /&gt;
- Discovered that image cropping step (not related to automated registration pipeline and SUVs computing) smoothes the images by doing interpolation when used with default settings. Got suggestions from Steve Piper using Nearest-Neighbor interpolation (&amp;quot;no interpolation&amp;quot;) for a time being&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
- This is the new project candidate. Requested for the images with failed manual segmentation and/or segmentation with FreeSurfer. The EM Segmentation run showed most acceptable results on one of the problem images back in February &amp;lt;br&amp;gt;&lt;br /&gt;
- The workflow will be developed and deployed similar to PET/CT ROI Longitudinal study approach - all preprocessing steps will be done with Slicer modules, all runs will be performed on local end-user machines.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
 &lt;br /&gt;
&lt;br /&gt;
* August 15 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- First 5 cases with 3-4 time points preprocessed for SUVs computation&lt;br /&gt;
&lt;br /&gt;
* August 8 2010&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Testing of installation and operation at users' site (Performed by Wendy Plesniak)&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* July 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Delivered beta version of registration pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
- Prepared installation and user manuals &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* June 11, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Registration modules completed &amp;lt;br&amp;gt;&lt;br /&gt;
- Irregular cases registration problem solved (when whole body and brain only scans are mixed for a timepoint)&amp;lt;br&amp;gt;&lt;br /&gt;
- Live demo of case setup and registration workflow for end users. Real case with 4 timepoints used&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Coming week plans&amp;lt;br&amp;gt;&lt;br /&gt;
- Adjust workflow based on end users' feedback&amp;lt;br&amp;gt;&lt;br /&gt;
- Integration with SUVs computing for PET scans&amp;lt;br&amp;gt;&lt;br /&gt;
- GUI for workflows dispatching and data organizing&amp;lt;br&amp;gt;&lt;br /&gt;
- (TBD) Integration with 4D time series analysis Slicer module&amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
* May 28, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- Migration to the latest Slicer 3.6 release candidate &amp;lt;br&amp;gt;&lt;br /&gt;
- Added webservice for new registration module: BRAINSFit &amp;lt;br&amp;gt;&lt;br /&gt;
- Test runs for new patients with 4 timepoints' scans &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Plans for next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI &amp;lt;br&amp;gt;&lt;br /&gt;
- processing workflow demo for end user &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 21, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Pilot version of portable web services and automated workflow tested: &amp;lt;br&amp;gt;&lt;br /&gt;
Linux: workflow and visual review passed&amp;lt;br&amp;gt;&lt;br /&gt;
Stress test for 25 timepoints passed &amp;lt;br&amp;gt;&lt;br /&gt;
MAC OS: workflow passed, visual review failing when PET/CT images are loaded into GUI simultaneously (bug report submitted)&amp;lt;br&amp;gt;&lt;br /&gt;
Windows: need to adapt command line modules and workflow management system to sygwin environment&amp;lt;br&amp;gt;&lt;br /&gt;
Plans for next week: integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI&lt;br /&gt;
&lt;br /&gt;
* May 7, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Selected registration and resampling modules with more precise and stable outputs. &amp;lt;br&amp;gt;&lt;br /&gt;
Started building portable web services and automated workflow &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 30, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- manual walk through the processing steps: ROI cropping, registration/resampling, PET pharmaceutical DICOM data retention. &amp;lt;br&amp;gt;&lt;br /&gt;
- testing workflow and web services packages distribution to end-users' machines&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* April 23, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : testing various registration and re-sampling algorithms (work in progress)&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation: as of collaborators' request, run existing EM Segmentation workflow for older low resolution pseudo-T1 images. The EM Segmentation works for those images with manual sampling. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 16, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
  Social Cognition Study: started Cortical Thickness Measurement module build (bases on NA-MIC ARCTIC pipeline) &amp;lt;br&amp;gt;&lt;br /&gt;
  PET/CT ROI/Longitudinal Study Registration : Design specs, PET-to-CT images registration tests on training data. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 9, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. GUI update based on end-user experience.&amp;lt;br&amp;gt;&lt;br /&gt;
User request: automated label maps' volumes calculation (Currently possible from Slicer3 GUI)&amp;lt;br&amp;gt; &lt;br /&gt;
PET/CT ROI Project. Initial design specs discussion with end-users and co-developers&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure&lt;br /&gt;
Verification of segmentation workflow GUI: from registering new case to reviewing results&amp;lt;br&amp;gt;&lt;br /&gt;
Cross study test of segmentation workflow: MGH/MS Center data - success,  HIV Project data - some EM Segmentation scene tuning is needed &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*&lt;br /&gt;
* April 2, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. Segmentation workflow completed&amp;lt;br&amp;gt;&lt;br /&gt;
* Coming Week plans:&amp;lt;br&amp;gt;&lt;br /&gt;
- Document Segmentation Workflow. Follow up with end users &amp;lt;br&amp;gt;&lt;br /&gt;
- Start with Cortical Thickness and ROI-in-longitudinal studies workflows&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* March 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All essential processing and workflow interaction clients are ready.&amp;lt;br&amp;gt;&lt;br /&gt;
- Completed segmentation for 10 out of 50 patients. The remaining cases will be finalized upon manual lesion segmentation and QC verification of WM/GM/CSF and Deep GM segmentation's. &amp;lt;br&amp;gt;&lt;br /&gt;
- TODO next week: refine QC GUI and data tracking / progress monitoring schema. &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&amp;lt;br&amp;gt;&lt;br /&gt;
- New Slicer3 web services added: re-slicing with reference image volume, casting image scalar type &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
* March 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Segmentation maps Merging Services for GM/WM/CSF (Slicer EM Segemnter), Lesion (Slicer, Manual), and Deep GM (FreeSurfer)  &amp;lt;br&amp;gt;&lt;br /&gt;
- Deep GM segmentation pipeline adopted as optional service for Social Cognition Study (22 out of 50 cases processed) &amp;lt;br&amp;gt;&lt;br /&gt;
- (In progress) GUI client for Launching Segmentation results merging with optional Deep GM segmentation with FreeSurfer &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- Complete GUI Client for Segmentation result merging &amp;lt;br&amp;gt;&lt;br /&gt;
- Progress Monitoring services for entire Study processing: EM Segmenter Preprocessing, EM Segmentation, Lesion Segmentation (including human activities assignments), Deep GM segmentation, and results consolidation. &amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* March 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All 50 cases went through &amp;quot;basic&amp;quot; One-channel EM segmentation (GM/WM/CSF) &amp;lt;br&amp;gt;&lt;br /&gt;
- Basic pipeline start-up command line client created: user has two options - request brainmask extraction or provide with previously extracted brainmask for a given subject &amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison of GM/WN/CSF performed for Slicer EM Segmenter and FreeSurfer recon-all (used with default settings). &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmenter provides more accurate output &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmentation pipeline runs faster (40 minutes vs 12 hrs when no brainmask extraction requested) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO:&amp;lt;br&amp;gt;&lt;br /&gt;
- merging modules for automatic 1-channel EM segmentation and manual lesion segmentation &amp;lt;br&amp;gt;&lt;br /&gt;
- Emerge Cortical Thickness pipeline project: use NAC ARCTIC processing steps and modules &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Selected stable EM Segmentation scenario: White Matter, Gray Matter, and Cerebrospinal Fluid &amp;lt;br&amp;gt;&lt;br /&gt;
- First 16 cases are segmented for selected scenario. Nine more cases are preprocessed for EM Segmentation.&amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison to segmentation with FreeSurfer showed better accuracy for Slicer2 EMSegmenter &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure &amp;lt;br&amp;gt;&lt;br /&gt;
- Three prerpcocessed cases failed during volume ICC masking with in-house build utility. Evaluated switching to Slicer3 Mask and island removing modules.&amp;lt;br&amp;gt;&lt;br /&gt;
- Initial design specs discussion for cortical thickness measurement pipeline. ARCTIC pipeline selected. ARCTIC preprocessing steps signifficantly overlap with EM Segmentation preprocessing workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
  &lt;br /&gt;
* February 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: &amp;lt;br&amp;gt;&lt;br /&gt;
A) parameters tuning for EM Segmenter itself (work with EM Segmenter developer), template scenes creation &amp;lt;br&amp;gt;&lt;br /&gt;
B) update preprocessing pipeline - deep gray matter atlases included &amp;lt;br&amp;gt;&lt;br /&gt;
C) test and debug preprocesing pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
D) identified missing modules: atlas autocalibration for EM Segmentation scene, Island removal for ICC mask&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- Review currently deployed modules. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: reviewed firts seven subjects' outputs, added volume orientation module into pipeline (prevents ICBM atlas linear registration failures)&amp;lt;br&amp;gt;&lt;br /&gt;
- Fused ICC(brainmask) extraction module with EM Segmenter preprocessing. Three scenarious implemented: start with pre-extracted ICC mask (longitudinal studies case), run with ICC ectration, run with ICC extraction AND ICC correction before ICBM atlas preporcessing. &amp;lt;br&amp;gt;&lt;br /&gt;
- Completion of Human activities GUI (QC, ICC Correction) planned for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: Volume Orientation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: automated preprocessing pipeline for Slicer2 EM Segmenter test version deployed. Seven cases pre-processed.&lt;br /&gt;
- PET Quantitative measurements: Preliminary design specs discussion.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: BSplineRegistration (for non-linear registration), ResampleVolume2 (for atlases resampling based on image atlase templates registration). Local and Network runs are implemented, Cluster/GridWizard implementation pending.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Slicer EM Segmenter module: preprocessing design for Slicer2 EM Segmenter&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Adapting for Slicer2 EM Segmenter (mostly from pipelines and services for previous projects)&lt;br /&gt;
  -- Integration with FreeSurfer modules for bisafield correction, brainmask extraction, and linear registration of ICBM atlases&lt;br /&gt;
  -- Preprocessing updates for non-linear registration of ICBM atlases with Slicer2 (image re-orientation service designed)&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 29, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- EM Segmentaton pipeline: preprocessing results are being transferred to XNat (anonymized data, Central XNat) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Slicer EM Segmenter module: discussed agenda and scheduled a work meeting for Social Cognition Study image segmentation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Testing stage, 95% completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- SPL XNat server: verified data exchange via RESTfull web services.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 22, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Follow up with White Matter Lesion Segmenter and Scull Stripping Modules developers: Work in Progress&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Work in Progress, 60%+ completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Discussed SPINE image repository migration to XNat&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 15, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. &lt;br /&gt;
- Social Cognition Study: &lt;br /&gt;
Work-in-progress on intermediate (reconstruction) and results (resources) data storage at XNat.&lt;br /&gt;
&amp;lt;br&amp;gt;Reviewing and preparation more cases for EM Segmentor (Slicer 3.5) tuning.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* NA-MIC Project Week&lt;br /&gt;
Selecting candidate Slicer modules for other than Lesion EM Segmentation topics of Social Cognition study: Withe Matter Lesion Segmenter (UNC), Scull Stripping utility from UIOWA.&lt;br /&gt;
Reviewing issues of currently used Scull Stripping Slicer Extension and Slicer 3.5 EM Segmenter.&lt;br /&gt;
&amp;lt;br&amp;gt;XNat Data organizing training&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 1, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Preparation of Demo for NA-MIC work week: &lt;br /&gt;
- COPD Study. Added Remote pipepline start interface (represents real world scenario where Xnat repository, Processing modules and User are at different sites)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
- EM Segmentation. Added human activities steps to the workflow: ICC (brainmask) correction and EM Segmantation scena load per se.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 25, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Pilot workflow pipeline for EM Segmentation (all steps except user-activity step: ICC correction assignment and tracking)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 18, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Build and tested web services for EM Segmentation image preprocessing: DICOM-to-NRRD conversion, registration, skull stripping, image masking.&lt;br /&gt;
Started building workflow pipeline (subject to finish first version next week)&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Started Collecting Library of Slicer Build number vs. functional modules and extensions.&lt;br /&gt;
Plan for NAMIC project week: scheduled meetings for XNat data customization, Skull-stripping modules tuning, identified Social Cognition study cases that fail EM Segmentation processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 11, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Updating and verification of EM Segmentation Scenario&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Projects:ARRA:SlicerWF:UseCaseScenarios#Usecase_MS_lesion_Assessment&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Familiarizing with Slicer3.4/5 Modules required for implementation of EM Segmentation Scenario. Participation in debugging and/or usage tuning of Dicom Conversion, Registration, Skull Stripping, Masking, and Image Casting modules. &lt;br /&gt;
&lt;br /&gt;
* December 4, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Slicer3.4's EM Segmentation and Visual QC as part of image processing pipeline for Social Cognition Study for MS Patients.&lt;br /&gt;
Project emerged. EM Segmentation template creation debugged.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
Emphysema Measurements (COPD Study) - workflow stability and scalability test.&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 27, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Emphysema Measurements (COPD Study).&lt;br /&gt;
Added compensation for long running calculations and time-outs to the main computing pipeline.&lt;br /&gt;
Visual QC (work in progress)&lt;br /&gt;
** Infrastructure&lt;br /&gt;
XNat data structure customization, metadata storage, results consolidation: new feature request list creation (work in progress)&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 13, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
*** Pilot system for whole processing cycle for Emphysema Measurements (COPD Study) including the following:&lt;br /&gt;
Web query for CT session file list download&lt;br /&gt;
Pilot user interface for submitting the file list and starting processing pipeline&lt;br /&gt;
Notification about processing steps and failures&lt;br /&gt;
Upload results to XNat repository (at this stage results are uploaded into same folder where original scans are(*))&lt;br /&gt;
*** Immediate Plans&lt;br /&gt;
Complete Visual QC module&lt;br /&gt;
Design and implement meta-data transfer to XNat (including processing details and MRML files for loading images into the 3D Slicer)&lt;br /&gt;
&lt;br /&gt;
(*)Customization of results storage&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 6, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Tuned and debugged multiple subjects processing for: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat.&lt;br /&gt;
***Started working on quality control embedding into the above scenario. Plan to complete and video-record demo next week.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***Published general Product Integration scenario flow chart to collaborators' community. Discussion is open and in progress&lt;br /&gt;
&lt;br /&gt;
* October 30, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Piloted and tested the sequence: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat(1).&lt;br /&gt;
***Performance test of overall cycle: data transfer from remote serve is a bottleneck as expected&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data browsing features reviewed.&lt;br /&gt;
(1) Not automated yet&lt;br /&gt;
* October 23, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Defined COPD processing scenario with interoperability between Xnat, 3D Slicer Command Modules, Workflow, and Gridwizard Enterprise.&lt;br /&gt;
***Pilot version of Emphysema Measurements workflow pipeline deployed.&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data transfer features reviewed. Use account at XNat Central during learning curve.&lt;br /&gt;
***Feasibility test of 3D Slicer fiducials module for ROI highlights during QC and manual image processing activities. &lt;br /&gt;
* October 16, 2009&lt;br /&gt;
**Lung CT Scans Processing. Pilot project emerged. GenerateEmphysemaMeasurements module deployed as a webservice that submits jobs to computational cluster.&lt;br /&gt;
**EM Segmentation. Familiarized with GUI steps. Started working on automation steps outlining&lt;br /&gt;
**3D Slicer and XNat interaction. Got an overview from Wendy Plesniak.&lt;br /&gt;
* October 1 - 7, 2009&lt;br /&gt;
**Selected two first priority Projects: EM Segmentation of brain MRI images; Lung CT Scans Processing (COPD Study)&lt;br /&gt;
**Got initial outline of user requirements and design specs&lt;/div&gt;</summary>
		<author><name>Azaitsev</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=69671</id>
		<title>Projects:ARRA:SlicerWF</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=69671"/>
		<updated>2011-06-29T19:02:55Z</updated>

		<summary type="html">&lt;p&gt;Azaitsev: /* Quarterly Progress */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Projects:ARRASuplements|Back to Slicer ARRA home page]]&lt;br /&gt;
= Aim =&lt;br /&gt;
Supplement 3D Slicer and Extensible Neuroimaging Archive Toolkit (XNAT) with workflow management system. Provide integration and interoperability between 3D Slicer, XNAT Services and 3-rd party image processing applications and high performance computing systems. Implement it as within currently developed Structural Planning and Implementation in Neurological Exploration (SPINE) System.&lt;br /&gt;
&lt;br /&gt;
= SPINE Project Documentation =&lt;br /&gt;
[http://cni.bwh.harvard.edu/projects/spine/index.html SPINE Docs]&lt;br /&gt;
&lt;br /&gt;
= Presentations =&lt;br /&gt;
* Segmentation Workflow. PECS University Social Cognition Study.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:SlicerWF_NAC_PECS_Workflow.pdf]]&lt;br /&gt;
* EAB10_ARRA Annual Progress Report Slides.&amp;lt;br&amp;gt;&lt;br /&gt;
[[media:EAB10_ARRA_WF_2011_Zaitsev.ppt | Service Oriented Solutions for 3D Slicer. EAB10_ARRA_WF_2011. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:EAB10_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:NAMIC_ARRA_WF_2011_Zaitsev.ppt  | NAMIC Annual Report 04/2010-03/2011. NAMIC_ARRA_WF_2011_Zaitsev. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:NAMIC_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:Slicer_WF_Slicer4CARMAWorkflow.ppt  | CARMA Workflow. Cardiac Ablation Followup. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:Slicer_WF_Slicer4CARMAWorkflow.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* CARMA Project Beta release Demo Location: http://cni29.bwh.harvard.edu/SlicerWFDemo/index.php&lt;br /&gt;
&lt;br /&gt;
* Segmentation Workflows: Screenshots, scans' and study description : [[File:SlicerWF_EMSegmentProjectsReview.zip]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
= All Hands Meeting Pages =&lt;br /&gt;
* Salt Lake City 2011 Winter [http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA SLC_2011_WorkFlow]&lt;br /&gt;
* MIT 2010 Summer [http://wiki.na-mic.org/Wiki/index.php/Summer_project_week_2010_Workflows_SOA MIT_2010_WorkFlow]&lt;br /&gt;
&lt;br /&gt;
= Research Plan =&lt;br /&gt;
*Create a stand-alone SPINE desktop agent with fully functional data exchange and communication mechanisms towards 3D Slicer and XNAT.&lt;br /&gt;
*Develop Service Oriented Architecture (SOA) SPINE System that will include 3D Slicer image processing modules deployed as web services as well as a workflow management system to orchestrate interaction between 3D Slicer, XNAT, and 3-rd party tools.&lt;br /&gt;
*Implement two-way control and communications between 3D Slicer and SPINE modules.&lt;br /&gt;
*Adapt SPINE System for cluster and grid computing scenarios.&lt;br /&gt;
*Provide with workflow and 3D Slicer web service wrappers editing tools.&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:UseCaseScenarios| Use Case scenarios]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PETCTWorkflow| PETCTWorkflow]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:AgingStudySegmentation| AgingStudySegmentation]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:TwoTensorTractography| TwoTensorTractography]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:LongitudinalMultimodalityRegistrationSuite| LongitudinalMultimodalityRegistrationSuite]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:MigrationJavaClients2QT| MigrationJavaClients2QT]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PediatricMSSegmentation| PediatricMSSegmentation]]&lt;br /&gt;
*[[DBP3:Utah:RegSegPipeline| MRI-based study and treatment of atrial fibrillation]]&lt;br /&gt;
&lt;br /&gt;
= Application Server / Workflow Engine Downloads =&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:WFEngineDownloads| Download Links]]&lt;br /&gt;
&lt;br /&gt;
=Key Personnel=&lt;br /&gt;
* Charles Gutmann, MD., 4%,  9-17-2009 through 9-16-2011&lt;br /&gt;
* Alexander Zaitsev, Ph.D., 75%, 9-17-2009 through 9-16-2011 &lt;br /&gt;
&lt;br /&gt;
=Annual Progress Statements =&lt;br /&gt;
'''2010-11''' &amp;lt;br&amp;gt;&lt;br /&gt;
The  April 2011 – March 2011 period was devoted on developing portable workflow solutions that can be deployed on end-users' workstations or notebooks with minimal or no system administration activities. This is in contrast to the server-side deployment. The following scenarios had been deployed and used for actual projects that require the following types of workflows: PET/CT registration and computation of biomarker driven brain physiological activities, Brain MRI Images segmentation,  MRI and MRI Angiography images pre-processing for cardiac ablation outcome estimation. Some  workflows (like EM Segmentation) had been utilizing various scenarios, some research projects  (like evaluation of chemotherapy outcome) require two types of workflows to assess physiological and structural changes. Starting from the 4th Quarter of 2011, the migration project had been emerged in order to embed Workflow GUIs into newly developed Slicer4 Suite. The existing rich client Java GUI applications are being re-written as C++/QT Sliceletts units, new modules (such as cardiac ablation project support) are had been written from scratch. The latter are being deployed from the Slicer4 GUI and act at a liaison between Slicer4 and Application Server containing  workflow and Slicer modules deployed as services. The feedback from the end users indicates that Workflow approach for the complex processing improves productivity, aids to the processing standardization and contributes to the overall experience using 3D Slicer&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
=Quarterly Progress=&lt;br /&gt;
&lt;br /&gt;
* '''2d Qtr, 2011''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study: Second release deployed. &lt;br /&gt;
*** End-users completed the first Project and currently analyzing SUV values and clinical data&lt;br /&gt;
*** New features added: Human Brain Hemispheres segmentation, Scull-stripping for total SUV counts calculation, Flexibility of custom designed label look-up table usage (users can define ROI notation according to the Project needs)&lt;br /&gt;
&lt;br /&gt;
** Left Atrium Ablation Assessment (CARMA Project)&lt;br /&gt;
*** Completed workflow pipeline for automated pre-processing and manual intervention&lt;br /&gt;
*** Developed front-end GUI for the CARMA Project support in Slicer4.&lt;br /&gt;
*** Run the workflow with the end users during NAMIC Project Week&lt;br /&gt;
*** Evaluated feasibility of left atrium wall and post-ablation scar segmentation using Robust Statistical Segmentation (RSS). Identified necessary processing controls with RSS module designers&lt;br /&gt;
&lt;br /&gt;
** Multiple Sclerosis CLIMB Study&lt;br /&gt;
*** Reprocessing for lesion segmentation&lt;br /&gt;
*** Developed Web-based (Java EE 6) application for submitting cases to the workflows for EM Segmentation of MPRAGE and registration to PD/T2/FLAIR images (60% completion)&lt;br /&gt;
&lt;br /&gt;
** EM Segmentation: &lt;br /&gt;
*** Upgraded EM Segmentation services to Slicer 3.6.4&lt;br /&gt;
*** Added brain hemispheres segmentation module to the workflows (used for PET/CT Longitudinal study)&lt;br /&gt;
*** Work with EM Segmenter module developers on building pipelines for white matter lesion segmentation (work in progress)&lt;br /&gt;
&lt;br /&gt;
** Plans for the 3rd quarter&lt;br /&gt;
*** Migrate CARMA Project workflow to end-users&lt;br /&gt;
*** Packaging of Slicer4 Workflow modules and Slicer4 custom build distribution &lt;br /&gt;
*** Completion of Web-base segmentation and registration suite&lt;br /&gt;
*** Users and Developers Documentation&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* NAMIC Annual Progress Slides (April 2010 - March 2011):&lt;br /&gt;
&lt;br /&gt;
* '''1st Qtr, 2011''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study: Second release is under testing by end-users. &lt;br /&gt;
*** Added MRI registration to aid ROI drawing on PET scans&lt;br /&gt;
*** Improved SUV results reporting and added flexibility to update ROI lookup table&lt;br /&gt;
*** Automated EM Segmentation of MRI images for computing SUVs for white matter, CSF, and whole brain (80% completion)&lt;br /&gt;
*** Integration with SPECTRE scull stripping module (70% completion) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** EM Segmentation: Automated WF Pipelines are created &amp;lt;br&amp;gt;&lt;br /&gt;
*** Flexible atlas selection (Pediatric, etc) feature added&lt;br /&gt;
*** Workflows implemented for EM Segmenter 3.6.2 and 3.6.3 (1st Qtr 2011 release)&lt;br /&gt;
&lt;br /&gt;
** Cardiac ablation results follow-up: Workflow for registration and ROI selection of cardiac MRI and MR Angiography &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Wrokflow and Web Services for prospective DTI tractography modules (currently written as Matlab modules at PNL) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Web Services for SPECTRE Scull stripping module&lt;br /&gt;
*** Accuracy and performance tuning&lt;br /&gt;
*** 50% completion&lt;br /&gt;
&lt;br /&gt;
** Migration Front End GUI to Slicer4/QT:&lt;br /&gt;
*** EM Segmentation&lt;br /&gt;
*** Cardiac Ablation Study&lt;br /&gt;
&lt;br /&gt;
** DICOM Uploader and Desktop Browser for XNat Image repository (alpha version - tested for MGH MS Center studies, proposed to use with MI2B2 Clients and Services)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''4th Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study and EM Segmentation for Aging Study are deployed at end-user sites and actively used for research. &lt;br /&gt;
** Adopted EM Segmentation preprocessing pipeline for HIV Study: high resolution SPGR images, integration with FreeSurfer brainmask extraction outputs; integration of Slicer SPECTRE module for brainmask extraction is in progress.&lt;br /&gt;
** The following post-release upgrades had been implemented based on end-user feedback: Application Server basic controls are performed from Rich Client GUI as alternative to traditional IT administration activities. The controls are implemented on point-and-click bases and include web services and workflow application deployment and upgrades, application server start and stop as well as warning end user when the server is not accepting request.&lt;br /&gt;
** Added DICOM downloads and results uploads of PET/CT pipelines from and to XNat Repository&lt;br /&gt;
** Created Services and Workflow for Matlab Prototypes modules. Case Study: tractography for DTI images&lt;br /&gt;
** Extended XNAT integration services:&lt;br /&gt;
*** Browsing capabilities of XNat data repository from the Workflow Applications&lt;br /&gt;
*** Improved DICOM upload and download performance&lt;br /&gt;
*** Added Metadata organizing services for uploaded DICOM images: header data extraction, image snapshots creation. &lt;br /&gt;
** Started project for Rich Client GUI migration from Java desktop application to build into SLicer4 QT modules. This affects mostly front-end GUI and has the following approaches: distribution with the Slicer4, end-user will select desired workflow application from Slicer4 menu while QT-written modules provide with the same functionality as Java Rich Clients. Case Study for the Migration process: registration suite for longitudinal studies that include multi-modality images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* '''3d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Concentrated on building downloadable workflow applications that could run both in desktop (new) and server environment, and that require minimum IT administrative resources. The desktop deployment is in compliance with Slicer3 general deployment concept.&lt;br /&gt;
*** The following use case scenario had been chosen: PET/CT image processing for longitudinal studies, EM Segmentation for longitudinal Aging Study.&lt;br /&gt;
** Released workflow application for PET/CT image processing for longitudinal studies. Provided end users with training and documentation.&lt;br /&gt;
*** The PET/CT processing workflow was designed to be a general application used whenever both structural patterns and metabolic activities are within the research scope. &lt;br /&gt;
*** The desktop version is tuned to use minimal computer resources, so the automates processing instances do not interfere with human activities. Automated activities may include, for example, registration and PET scan's standard uptake values computing, and manual human activities may include image cropping, quality control, and labeling voxels of interest.&lt;br /&gt;
** Core services and EM Segmentation preprocessing workflow was build for retrospective Aging Study. Tuned the Slicer3 webservices for processing low grade images acquired in mid 90s. Entire workflow is implemented with Slicer3 only modules and can be deployed locally and on the servers. Usage of Service Oriented Architecture (SOA) as a core technological approach allowed reusing most of the web services that had been build for PET/CT project. &lt;br /&gt;
** Continued embedding Slicer3 application and modules into previously released processing pipelines: replaced MIPAV with Slicer3 GUI for lesion assessment step in the multi-center Pediatric MS Cohort image processing &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''2d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Completed Social Cognition Workflow Implementation. This includes EM Segmetnation pre- and post-processing pipelines, data tracking, and integration with 3d party image processing utilities, as well as processing results acquired manually with Slicer GUI.  &lt;br /&gt;
** Multi-modality image registration and ROI selection/alignment workflow for longitudinal studies. &lt;br /&gt;
*** Use case: PET/CT image processing for longitudinal studies. &lt;br /&gt;
*** Build portable library of Slicer modules as web services and workflow that are deployed and run on a end-users' worksatations without utilization of SPL and other servers. The web services include novel Slicer3 modules, such as BRAINSFit and BRAINSResamle &lt;br /&gt;
*** Started working with Slicer3 developers on Slicer 3.8 GUI wizard to communicate with workflow instances.&lt;br /&gt;
** Participated at NA-MIC Summer 2010 Project Week: [[Summer_project_week_2010_Workflows_SOA]]&lt;br /&gt;
&lt;br /&gt;
=Progress=&lt;br /&gt;
*June 24, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
Project Week:&lt;br /&gt;
* Testing RSS module for left atrial wall scar segmentation&lt;br /&gt;
* Testing EM Segmenter for lesion detection on PD (requested by end-users) and FLAIR images&lt;br /&gt;
&lt;br /&gt;
EM Segmentation &lt;br /&gt;
* Web-based segmentation and registration module for MS Center. Goal: facilitate 3D SLicer modules for the cases that could not be processed with in-house build DTS+ algorithm&lt;br /&gt;
* Pipeline: Segment MPGR or T1 (user's choice), Register MPGR to PD/T2, Resample Segmentation Map to PD/T2. Completion: 60-70%.&lt;br /&gt;
* The rest will be done manually or via lesion segmentation with EM Segmenter.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* June 17, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
Preparation for Project Week&lt;br /&gt;
&lt;br /&gt;
* June 10, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
CARMA V.1.0&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code completed and tested&lt;br /&gt;
* Packaging as extension is pending (Subject for Summer 2011 Project week)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Debugging consolidation results issue(SUVs for manual and automated segmentation) &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* June 3, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Deployed on end-user's machine&lt;br /&gt;
* TODO next week: fix SUV results consolidation issue (when MRI segmented ROI got SUV computed for some subjects, only those subjects' SUVs are being added into consolidated report. &amp;quot;Raw&amp;quot; SUV values per subject are generated as expected)  &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 27, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Ready for deployment. New Features: hemispheres EM Segmentation, automated ICC/brainmask extraction using EM Segmenter, fixed controls for MRI conversion and registration&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 20, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General / PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Hemispheres EM Segmentation - adjusted for required label lookup table&lt;br /&gt;
* Use cases added for EM Segmenter General Project: http://www.slicer.org/slicerWiki/index.php/EMSegmenter-Tasks#EMSegmenter_use_cases&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SPECTRE Scull Stripping&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* The new version to be tested on coming week (After PETCT MRI processing migrated to Hemispheres scenario )&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* May 13, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General / PETCT V1.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Hemispheres EM Segmentation - technically works with labal values hardcoded in Slicer EM Segmenter - need to add manual label value edition step&lt;br /&gt;
* PETCT WF Cut for Java GUI (Pending Hemispheres label update completion). Next release will be in QT4.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* May 6, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (QA of EM Segmenter module, work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* April 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Open Discussion for Packaging WF QT Modules as Slicer4 extensions (waiting for SOPs)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review supported projects http://wiki.na-mic.org/Wiki/index.php/File:SlicerWF_EMSegmentProjectsReview.zip &lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (required by Study)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Slicer Modules General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Standardizing Crop Volumes Output (with A. Fedorov's module). Review for required updates of existing product (PET/CT, CARMA)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Open Discussion for Packaging WF QT Modules as Slicer4 extensions (waiting for SOPs)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review supported projects http://wiki.na-mic.org/Wiki/index.php/File:SlicerWF_EMSegmentProjectsReview.zip &lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (required by Study)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Slicer Modules General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Standardizing Crop Volumes Output (with A. Fedorov's module)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 22, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Beta release ready. Demo Location: http://cni29.bwh.harvard.edu/SlicerWFDemo/index.php&lt;br /&gt;
* TODO: Tutorial. Original inputs copy/renaming&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 15, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Adding App server auto-config features&lt;br /&gt;
* Finalizing the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 08, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Second release beta build tested on cosutmer side &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review registration quality (with Dr. Meier). Angiography images' Resampling tuned. &lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 01, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the second release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
XNat Integration&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* (Java) GUI for Project Browsing and DICOM Series Upload. Post-upload DICOM processing tested and debugged&amp;lt;br&amp;gt;&lt;br /&gt;
* Ready for integration with mi2b2 client.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Migrated to Latest Slicer 3.6.3 stable release: only the Input scene had to be updated, the API remained the same&lt;br /&gt;
* Tested EM Segmenter with CMTK4Slicer extension - processing takes to much time on Linux_64bit machine, rolled back to BRAINSFit registration. When used on Mac OS X build, the Slicer could not start (bug report 1126).&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SPECTRE Scull Stripping:&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Testes for various use cases: the module is extremely sensitive to T1 MRI quality (does not work for most MRIs from PET/CT project&lt;br /&gt;
* TODO next week: check for FLAIR images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Slicer4 QT GUI and Cropping activity in progress.&amp;lt;br&amp;gt;&lt;br /&gt;
* Tried direct MRA to MRA registration option: resampling with LMRI registration transforms works better.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Extra VOI labels revised&lt;br /&gt;
* Debugging of SUV results' renormalization step&lt;br /&gt;
* TODO: ICC extraction / whole brain total uptake computing; EM Segmentation for R_WM, L_WM SUV computing and BPH estimation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SCULL STRIPPING/SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Installed and tested CLI option on Linux_64bit platform&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Workflow interruption before BSPline registraton: BPEL Module completed. Slicer4 QT GUI and Cropping activity in prorgess.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Implemented and Tested with end-users proposed changes: denormalization of SUV results, adding more VOI labels, added FLAIR MRI in addition to T1s for VOI drawing&lt;br /&gt;
* Tested manual ICC extraction using PET scans: works satisfactory with island removal and cropping followed by threshold level labeling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4&lt;br /&gt;
* Change proposed: interrupt workflow after affine registration and have user crop the VOI. This is to prevent excessive deformations for BSpline registration and resampling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4. User has option to choose the atlas that fits better for the given subject (NOTE: hardcoding must be rewritten for atlas linking)&lt;br /&gt;
* PETCT test - the problem is that T1s are low resolution and with contrast. Proposed using T1s without contrast&lt;br /&gt;
* PETCT change request: users wants to compute SUV for entire ICC. Had demo how to segment brainmask/ICC using PET scan. The derived brainmask label can be used for SUV computation.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - cmpleted&lt;br /&gt;
* Sample cases run - excessive deformation after BSpline registration hase&lt;br /&gt;
* Next week plan - pull tuning controls to front-end of pipeline API, start working of QT module for CARMA registration&lt;br /&gt;
* May consider other than BRAINSFit registration modules&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Design plan for change request: more VOI labels, add FLAIR in addition to T1 for VOI drawing, T1s segmentation&lt;br /&gt;
* Tested segmentation for sample cases - artifacts from poor quality MRIs lead to exclusion of parts of ICC from segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Completed troubleshooting of EMSegmenter module calling from Java (need TCL libs to be pulled from Slicer environment)&lt;br /&gt;
* Tested EMSegmenter autoruns for HIV and Pediatric MS patiens. Work as expected, subject to improvement of PED MS case segmentation by building better skull/neck/air atalses&lt;br /&gt;
* Suggested usage of two subsets of atalases: with and without neck. The Subject MRIs have to be cropped accordingly or best fit atlas has to be selected&lt;br /&gt;
* Made no-neck cropped atlas collection for default EMSegmenter scenario&lt;br /&gt;
* Tested with PET/CT study MRI cases - see above &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - in progress&lt;br /&gt;
* Next week goal - have back end processing ready&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Longitudinal Study&lt;br /&gt;
* Added MRI registration to the pipeline&lt;br /&gt;
* Troubleshooting of complex XML schema issues on Linux machines (some modules working on MAC do not work on Linux). As a workaround - did not include MRI convert and register part into base BPEL module. Used separate services (transparent for end-user)&lt;br /&gt;
* TODO next week for change request completion: explicit pixel type casting for MRI in BRAINSFit, VOI MRML scene update (currently MRI added on top of schema)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* February 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipeline for Pediatric MRI. Same scenario as for HIV Project, icbm pediatric atlases (Completed, verified)&lt;br /&gt;
* Collected NIH healthy brain development atlases: various age ranges from 4.5 to 18 yo. Converted to Slicer readable format &lt;br /&gt;
* Work on web services for the new automated EM Segmenter module (release Nov 10 - current). Verified task completion both for adult and pediatric images. Discussed tuning parameters for work load balance on workstations.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Started working on MRI registration to the reference CT scans. &lt;br /&gt;
* Design specs for optional White Matter segmentation for SUV computing.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* February 4, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipelines for Pediatric MRI (in progress)&lt;br /&gt;
* Adapting Pediatric T1 atlases for &amp;quot;Human Brain&amp;quot; build-in EM Segmentation wizard (in progress)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 28, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Verifying EM Segmenter module for latest builds and HIV/PED MS Studies (report pending)&lt;br /&gt;
* Work with SPECTRE module developers with pediatric MRI brainmask extraction&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* January 21, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Compiling plan for WF FrontEnd GUI migration to Slicer4/QT Widgets&lt;br /&gt;
* Preparing for annual progress report&lt;br /&gt;
&lt;br /&gt;
* January 14, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI: Integrated into the Slicer4 as Slicelet (or thin Client)&lt;br /&gt;
* Participation at AHM-2011, discussing integration of SPECTRE module and updated approach to EM-Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA&lt;br /&gt;
&lt;br /&gt;
* January 7, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* HIV project workflow delivered. Major additions relate to user convenience: &lt;br /&gt;
- Project-specific parameter settings, importing T1s and brainmasks from FreeSurfer outputs with conversion to NIFTI, resampling brainmask to original scans and automatied subject addition.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Follow up with end user: need to add MRI scans, if available, addition and registration to CT in order to ease VOI drawings.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
 &lt;br /&gt;
* December 31, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Follow-up with user Experience for AGING Study Segmentation (Positive feedback)&lt;br /&gt;
* Target date for HIV project delivery - next week&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Self-training for QT widget development&amp;lt;br&amp;gt;&lt;br /&gt;
* Outlined Workflow Rich Clients migration strategy from Java to QT/Slicer4:&amp;lt;br&amp;gt;&lt;br /&gt;
** Use Java Stubs (similar to SPECTRE integration) or file binding for envocation of workflow pipelines. (See SOAP remark below)&lt;br /&gt;
** Direct Web Servisec calls must be wrapped into REST protocol. The reason: NON-commerchial QT kit does not include SOAP protocol for web servises.&lt;br /&gt;
** The GUI will be implemented as page widget or QT dialog GUI forms called from within Slicer4.&lt;br /&gt;
** Communications between Slicer4 and WF GUI will be set via child-parent and signal-slot relations&lt;br /&gt;
* Worked on a Prototype for Basic EM Segmentation QT widget (70% complete). Will work on integrtion with SLicer4 during the AHM-2010&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
XNAT Integration&lt;br /&gt;
* Debugged XNAT RESTFul API usage for uplaoding DICOM series followed by header data extraction and image snapshots creation&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Added compensation for failed atlas registration (subject for old poor quality pseudo-T1 images): blank probability maps are created in case of failure.&lt;br /&gt;
* Data preparation module for FreeSurfer data import near completion. Expected time for deployment at end-users workstations - first week of January&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Discussed strategy for EM Segmentation pipeline solutions collection (K. Pohl, R. Kikinis)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* RE-using the same core workflow as for 1-channel EM Segmentation of AGING STUDY cases&lt;br /&gt;
* Added data input preparation module: ICC label mask preparation and skull-stripping based on FreeSurfer brainmask output volume.&lt;br /&gt;
* Two-channel EM segmentation pipeline (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE / GENERAL Development &amp;lt;br&amp;gt;&lt;br /&gt;
* Worked on plans for migrating fro rich workflow Java clients to embedded workflow windows inside the Slicer.&amp;lt;br&amp;gt;&lt;br /&gt;
The embedded workflow management clients are to be implemented with QT/PyQT toolkits&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
INTEGRATION WITH XNAT:&amp;lt;br&amp;gt;&lt;br /&gt;
* Automated DICOM series upload with triggering DICOM headers parsing at XNat site (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress. &lt;br /&gt;
- Results upload to XNat (Completed) &amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat based on user's input (Project + Subject + PET or CT session / scan) (Completed)&amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat - perfomance boosting solution for downloads found , web services services are created, relinking for the client side in progress &amp;lt;br&amp;gt;&lt;br /&gt;
- Xnat querying for subjects and automated subject addition into the workflow (In Progress) &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-segmentation module added for auto correction of segmentation results. Particularly - relabeling CSF voxels segmented as Air inside the intracranial cavity. This was requested by end-users after processing images with zero-signals in CSF voxels &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting automated dual-echo DICOM images conversion and split into two NRRD volumes&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT / EM Segmentation pipeline:&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting memory allocation issues for scull-stripping module SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
COPD Project:&amp;lt;br&amp;gt;&lt;br /&gt;
* Benchmark test for accelerated DICOM downloads from XNat (remoote XNat Central server): we can handle at least 6 cases (4 CT scans in each) per hour, which is compatible with current workload quotes on SPL cluster processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* December 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Deployed Version 1. &amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Test project chosen as a closest match to registration scenario: Pediatric MS Cases from MGH - requires periodic image preview for different &lt;br /&gt;
modalities taken from vaious time points. Label maps for VOIs resampling is also required.&lt;br /&gt;
&lt;br /&gt;
* November 26, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user. Version 1 is complete&amp;lt;br&amp;gt;&lt;br /&gt;
* Started working on integration with XNat&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on input data organizing modules&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 19, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user (70% done)&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Universal Registration Workflow for Longitudinal Studies - design specs in progress&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 12, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Minor tuning to EM Segmentation template as of users' feedback&lt;br /&gt;
* Users started using the workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed input data conversion from Genesis to Slicer native or NIFTI format. Our help may be needed in input data organizing.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Tuned application according to co-laborators (PNL) needs&amp;lt;br&amp;gt;&lt;br /&gt;
* The webservices and BPEL workflow application are tested ready to accept computation requests from PNL case tracking system &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Discussed Universal Registration Workflow for Longitudinal Studies&lt;br /&gt;
* Started the thread about possible cooperation with Children hospital's image processing pipelines and integration with Xnat &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 5, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Webservices and workflow pilot project created and deployed on Psychiatry Neuroimaging Laboratory subnet &amp;lt;br&amp;gt;&lt;br /&gt;
* The V.1.0 deployment is scheduled for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 29, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Most of functionality is completed. Some volume statistics post processing is pending&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL EM SEGMENTATION Pipeline: &amp;lt;br&amp;gt;&lt;br /&gt;
* The SPECTRE scull stripping module. Started integration into EMS workflow. Made some test runs from Slicer GUI&amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Identified as a candidate for Workflow Application&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 22, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* All back-end functionality are implemented&amp;lt;br&amp;gt;&lt;br /&gt;
* EM Segmentation scene usability is confirmed by end-user&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for next week: add Label Statistics computation for CSF/Brain/ICC &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 15, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* The latest (October) builds of Slicer 3.6.2 produced acceptable results. This was verified by the target users. The EM Segmentation will be performed on Slicer 3.6.2 or later&amp;lt;br&amp;gt;&lt;br /&gt;
* The new Web services had been created and added to the pipeline as optional processing steps: Biasfield correction (implement novel N2ITKBiasFieldCorrection module) and Volume's scalar datatype casting (as workaround for Biasfield correction module not preserving image scalar datatype - the bug is filed) &amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed the Front-End GUI design with target users. The design pattern is taken from the PETCT project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 8, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-deployment support. Tuned CT registration as of user's feedback.&lt;br /&gt;
* Adapting to the Single Slicer build: Slicer 3.6.2. Found label duplicates in the label lookup table - will ask user if it's tolerable. Waiting for the Slicer 3.6.2 build that contains all required modules. Rolling back label tag appending code for SUVs - the latest Slicer build appends the tags.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Resumed development. The priorities are set for usage of Slicer 3.6.2 - subject for EM Segmentation scene tuning. Continued coding for Scene creation for Slicer 2.8 - as a backup option for ongoing research project.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 1, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized V1.0 release based on end-user feedback: updates relate mostly to error proofing and SUV values representation&lt;br /&gt;
* Post-deployment support. Users pre-processed first set of patients &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* September 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* System deployed and tested at End Users' site.&amp;lt;br&amp;gt;Users are trained to perform all tasks required by the workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
* Got positive feedback with suggestions on Slicer Scenes' layouts improvement and PET scans' SUV (standard uptake values) results display&lt;br /&gt;
* Two distribution packages are assembled: Lunix and MAC OS versions. The difference in two packages is in specific Slicer3.6/3.7 builds - subject to Slicer Linux builds debugging.&amp;lt;br&amp;gt; As a workaround for Linux deployment - multiple Slicer builds are used to perform various tasks (registration, opening editing scenes in Slicer, SUV computing)&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for coming week - finalize V1.0 release based on end-user feedback&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Embedded SUV computations into the workflow (as system calls - will be translated into web service later)&amp;lt;br&amp;gt;&lt;br /&gt;
* Pre-release demo for end users.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Create and debug EM Segmenter scenes template for Slicer 3.6 and 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* September 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation - workflow pipeline and deployment verified&amp;lt;br&amp;gt;&lt;br /&gt;
* Tested EM Segmentation scenes within Slicer 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
* Started migration of EM Segmentation to Slicer 3.6. Discovered issues had been reported to EM Segmenter module designers &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* August 29 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation completed. Preprocessing Pipleine completed 80% (subject for input registration parameters tuning) &amp;lt;br&amp;gt;&lt;br /&gt;
* Most webservices (for registration and resampling steps) had been taken and re-used from PET/CT ROI/Longitudinal Study - showing the advantage of service-oriented software design and deployment.&lt;br /&gt;
* Continued on distribution and deployment of the service/workflow applications: on PET/CT and AGING STUDY projects.&lt;br /&gt;
&lt;br /&gt;
PEDIATRIC Multiple Sclerosis Cohort. Support of multi-center distributed processing project&amp;lt;br&amp;gt;&lt;br /&gt;
* Introduced Slicer 3.6 for the MS Lesion Assessment step performed at Mayo Clinic. Images are being transferred from image repository at BWH and automatically opened and arranged within Slicer GUI for reading.  This was replacement of Client GUI using MIPAV that stopped working on new computers at Mayo Clinic.&lt;br /&gt;
The images are being loaded via generated MRML Scenes same way as in PET/CT and AGING STUDY projects &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* August 22 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Preprocessing pipeline merge with SUV computations &amp;lt;br&amp;gt;&lt;br /&gt;
- QA for SUVs computation was performed by Wendy Plesniak for images with known uptake values. &amp;lt;br&amp;gt;&lt;br /&gt;
- Discovered that image cropping step (not related to automated registration pipeline and SUVs computing) smoothes the images by doing interpolation when used with default settings. Got suggestions from Steve Piper using Nearest-Neighbor interpolation (&amp;quot;no interpolation&amp;quot;) for a time being&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
- This is the new project candidate. Requested for the images with failed manual segmentation and/or segmentation with FreeSurfer. The EM Segmentation run showed most acceptable results on one of the problem images back in February &amp;lt;br&amp;gt;&lt;br /&gt;
- The workflow will be developed and deployed similar to PET/CT ROI Longitudinal study approach - all preprocessing steps will be done with Slicer modules, all runs will be performed on local end-user machines.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
 &lt;br /&gt;
&lt;br /&gt;
* August 15 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- First 5 cases with 3-4 time points preprocessed for SUVs computation&lt;br /&gt;
&lt;br /&gt;
* August 8 2010&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Testing of installation and operation at users' site (Performed by Wendy Plesniak)&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* July 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Delivered beta version of registration pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
- Prepared installation and user manuals &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* June 11, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Registration modules completed &amp;lt;br&amp;gt;&lt;br /&gt;
- Irregular cases registration problem solved (when whole body and brain only scans are mixed for a timepoint)&amp;lt;br&amp;gt;&lt;br /&gt;
- Live demo of case setup and registration workflow for end users. Real case with 4 timepoints used&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Coming week plans&amp;lt;br&amp;gt;&lt;br /&gt;
- Adjust workflow based on end users' feedback&amp;lt;br&amp;gt;&lt;br /&gt;
- Integration with SUVs computing for PET scans&amp;lt;br&amp;gt;&lt;br /&gt;
- GUI for workflows dispatching and data organizing&amp;lt;br&amp;gt;&lt;br /&gt;
- (TBD) Integration with 4D time series analysis Slicer module&amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
* May 28, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- Migration to the latest Slicer 3.6 release candidate &amp;lt;br&amp;gt;&lt;br /&gt;
- Added webservice for new registration module: BRAINSFit &amp;lt;br&amp;gt;&lt;br /&gt;
- Test runs for new patients with 4 timepoints' scans &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Plans for next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI &amp;lt;br&amp;gt;&lt;br /&gt;
- processing workflow demo for end user &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 21, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Pilot version of portable web services and automated workflow tested: &amp;lt;br&amp;gt;&lt;br /&gt;
Linux: workflow and visual review passed&amp;lt;br&amp;gt;&lt;br /&gt;
Stress test for 25 timepoints passed &amp;lt;br&amp;gt;&lt;br /&gt;
MAC OS: workflow passed, visual review failing when PET/CT images are loaded into GUI simultaneously (bug report submitted)&amp;lt;br&amp;gt;&lt;br /&gt;
Windows: need to adapt command line modules and workflow management system to sygwin environment&amp;lt;br&amp;gt;&lt;br /&gt;
Plans for next week: integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI&lt;br /&gt;
&lt;br /&gt;
* May 7, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Selected registration and resampling modules with more precise and stable outputs. &amp;lt;br&amp;gt;&lt;br /&gt;
Started building portable web services and automated workflow &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 30, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- manual walk through the processing steps: ROI cropping, registration/resampling, PET pharmaceutical DICOM data retention. &amp;lt;br&amp;gt;&lt;br /&gt;
- testing workflow and web services packages distribution to end-users' machines&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* April 23, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : testing various registration and re-sampling algorithms (work in progress)&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation: as of collaborators' request, run existing EM Segmentation workflow for older low resolution pseudo-T1 images. The EM Segmentation works for those images with manual sampling. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 16, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
  Social Cognition Study: started Cortical Thickness Measurement module build (bases on NA-MIC ARCTIC pipeline) &amp;lt;br&amp;gt;&lt;br /&gt;
  PET/CT ROI/Longitudinal Study Registration : Design specs, PET-to-CT images registration tests on training data. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 9, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. GUI update based on end-user experience.&amp;lt;br&amp;gt;&lt;br /&gt;
User request: automated label maps' volumes calculation (Currently possible from Slicer3 GUI)&amp;lt;br&amp;gt; &lt;br /&gt;
PET/CT ROI Project. Initial design specs discussion with end-users and co-developers&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure&lt;br /&gt;
Verification of segmentation workflow GUI: from registering new case to reviewing results&amp;lt;br&amp;gt;&lt;br /&gt;
Cross study test of segmentation workflow: MGH/MS Center data - success,  HIV Project data - some EM Segmentation scene tuning is needed &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*&lt;br /&gt;
* April 2, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. Segmentation workflow completed&amp;lt;br&amp;gt;&lt;br /&gt;
* Coming Week plans:&amp;lt;br&amp;gt;&lt;br /&gt;
- Document Segmentation Workflow. Follow up with end users &amp;lt;br&amp;gt;&lt;br /&gt;
- Start with Cortical Thickness and ROI-in-longitudinal studies workflows&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* March 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All essential processing and workflow interaction clients are ready.&amp;lt;br&amp;gt;&lt;br /&gt;
- Completed segmentation for 10 out of 50 patients. The remaining cases will be finalized upon manual lesion segmentation and QC verification of WM/GM/CSF and Deep GM segmentation's. &amp;lt;br&amp;gt;&lt;br /&gt;
- TODO next week: refine QC GUI and data tracking / progress monitoring schema. &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&amp;lt;br&amp;gt;&lt;br /&gt;
- New Slicer3 web services added: re-slicing with reference image volume, casting image scalar type &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
* March 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Segmentation maps Merging Services for GM/WM/CSF (Slicer EM Segemnter), Lesion (Slicer, Manual), and Deep GM (FreeSurfer)  &amp;lt;br&amp;gt;&lt;br /&gt;
- Deep GM segmentation pipeline adopted as optional service for Social Cognition Study (22 out of 50 cases processed) &amp;lt;br&amp;gt;&lt;br /&gt;
- (In progress) GUI client for Launching Segmentation results merging with optional Deep GM segmentation with FreeSurfer &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- Complete GUI Client for Segmentation result merging &amp;lt;br&amp;gt;&lt;br /&gt;
- Progress Monitoring services for entire Study processing: EM Segmenter Preprocessing, EM Segmentation, Lesion Segmentation (including human activities assignments), Deep GM segmentation, and results consolidation. &amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* March 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All 50 cases went through &amp;quot;basic&amp;quot; One-channel EM segmentation (GM/WM/CSF) &amp;lt;br&amp;gt;&lt;br /&gt;
- Basic pipeline start-up command line client created: user has two options - request brainmask extraction or provide with previously extracted brainmask for a given subject &amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison of GM/WN/CSF performed for Slicer EM Segmenter and FreeSurfer recon-all (used with default settings). &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmenter provides more accurate output &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmentation pipeline runs faster (40 minutes vs 12 hrs when no brainmask extraction requested) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO:&amp;lt;br&amp;gt;&lt;br /&gt;
- merging modules for automatic 1-channel EM segmentation and manual lesion segmentation &amp;lt;br&amp;gt;&lt;br /&gt;
- Emerge Cortical Thickness pipeline project: use NAC ARCTIC processing steps and modules &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Selected stable EM Segmentation scenario: White Matter, Gray Matter, and Cerebrospinal Fluid &amp;lt;br&amp;gt;&lt;br /&gt;
- First 16 cases are segmented for selected scenario. Nine more cases are preprocessed for EM Segmentation.&amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison to segmentation with FreeSurfer showed better accuracy for Slicer2 EMSegmenter &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure &amp;lt;br&amp;gt;&lt;br /&gt;
- Three prerpcocessed cases failed during volume ICC masking with in-house build utility. Evaluated switching to Slicer3 Mask and island removing modules.&amp;lt;br&amp;gt;&lt;br /&gt;
- Initial design specs discussion for cortical thickness measurement pipeline. ARCTIC pipeline selected. ARCTIC preprocessing steps signifficantly overlap with EM Segmentation preprocessing workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
  &lt;br /&gt;
* February 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: &amp;lt;br&amp;gt;&lt;br /&gt;
A) parameters tuning for EM Segmenter itself (work with EM Segmenter developer), template scenes creation &amp;lt;br&amp;gt;&lt;br /&gt;
B) update preprocessing pipeline - deep gray matter atlases included &amp;lt;br&amp;gt;&lt;br /&gt;
C) test and debug preprocesing pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
D) identified missing modules: atlas autocalibration for EM Segmentation scene, Island removal for ICC mask&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- Review currently deployed modules. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: reviewed firts seven subjects' outputs, added volume orientation module into pipeline (prevents ICBM atlas linear registration failures)&amp;lt;br&amp;gt;&lt;br /&gt;
- Fused ICC(brainmask) extraction module with EM Segmenter preprocessing. Three scenarious implemented: start with pre-extracted ICC mask (longitudinal studies case), run with ICC ectration, run with ICC extraction AND ICC correction before ICBM atlas preporcessing. &amp;lt;br&amp;gt;&lt;br /&gt;
- Completion of Human activities GUI (QC, ICC Correction) planned for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: Volume Orientation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: automated preprocessing pipeline for Slicer2 EM Segmenter test version deployed. Seven cases pre-processed.&lt;br /&gt;
- PET Quantitative measurements: Preliminary design specs discussion.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: BSplineRegistration (for non-linear registration), ResampleVolume2 (for atlases resampling based on image atlase templates registration). Local and Network runs are implemented, Cluster/GridWizard implementation pending.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Slicer EM Segmenter module: preprocessing design for Slicer2 EM Segmenter&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Adapting for Slicer2 EM Segmenter (mostly from pipelines and services for previous projects)&lt;br /&gt;
  -- Integration with FreeSurfer modules for bisafield correction, brainmask extraction, and linear registration of ICBM atlases&lt;br /&gt;
  -- Preprocessing updates for non-linear registration of ICBM atlases with Slicer2 (image re-orientation service designed)&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 29, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- EM Segmentaton pipeline: preprocessing results are being transferred to XNat (anonymized data, Central XNat) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Slicer EM Segmenter module: discussed agenda and scheduled a work meeting for Social Cognition Study image segmentation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Testing stage, 95% completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- SPL XNat server: verified data exchange via RESTfull web services.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 22, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Follow up with White Matter Lesion Segmenter and Scull Stripping Modules developers: Work in Progress&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Work in Progress, 60%+ completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Discussed SPINE image repository migration to XNat&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 15, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. &lt;br /&gt;
- Social Cognition Study: &lt;br /&gt;
Work-in-progress on intermediate (reconstruction) and results (resources) data storage at XNat.&lt;br /&gt;
&amp;lt;br&amp;gt;Reviewing and preparation more cases for EM Segmentor (Slicer 3.5) tuning.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* NA-MIC Project Week&lt;br /&gt;
Selecting candidate Slicer modules for other than Lesion EM Segmentation topics of Social Cognition study: Withe Matter Lesion Segmenter (UNC), Scull Stripping utility from UIOWA.&lt;br /&gt;
Reviewing issues of currently used Scull Stripping Slicer Extension and Slicer 3.5 EM Segmenter.&lt;br /&gt;
&amp;lt;br&amp;gt;XNat Data organizing training&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 1, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Preparation of Demo for NA-MIC work week: &lt;br /&gt;
- COPD Study. Added Remote pipepline start interface (represents real world scenario where Xnat repository, Processing modules and User are at different sites)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
- EM Segmentation. Added human activities steps to the workflow: ICC (brainmask) correction and EM Segmantation scena load per se.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 25, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Pilot workflow pipeline for EM Segmentation (all steps except user-activity step: ICC correction assignment and tracking)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 18, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Build and tested web services for EM Segmentation image preprocessing: DICOM-to-NRRD conversion, registration, skull stripping, image masking.&lt;br /&gt;
Started building workflow pipeline (subject to finish first version next week)&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Started Collecting Library of Slicer Build number vs. functional modules and extensions.&lt;br /&gt;
Plan for NAMIC project week: scheduled meetings for XNat data customization, Skull-stripping modules tuning, identified Social Cognition study cases that fail EM Segmentation processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 11, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Updating and verification of EM Segmentation Scenario&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Projects:ARRA:SlicerWF:UseCaseScenarios#Usecase_MS_lesion_Assessment&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Familiarizing with Slicer3.4/5 Modules required for implementation of EM Segmentation Scenario. Participation in debugging and/or usage tuning of Dicom Conversion, Registration, Skull Stripping, Masking, and Image Casting modules. &lt;br /&gt;
&lt;br /&gt;
* December 4, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Slicer3.4's EM Segmentation and Visual QC as part of image processing pipeline for Social Cognition Study for MS Patients.&lt;br /&gt;
Project emerged. EM Segmentation template creation debugged.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
Emphysema Measurements (COPD Study) - workflow stability and scalability test.&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 27, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Emphysema Measurements (COPD Study).&lt;br /&gt;
Added compensation for long running calculations and time-outs to the main computing pipeline.&lt;br /&gt;
Visual QC (work in progress)&lt;br /&gt;
** Infrastructure&lt;br /&gt;
XNat data structure customization, metadata storage, results consolidation: new feature request list creation (work in progress)&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 13, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
*** Pilot system for whole processing cycle for Emphysema Measurements (COPD Study) including the following:&lt;br /&gt;
Web query for CT session file list download&lt;br /&gt;
Pilot user interface for submitting the file list and starting processing pipeline&lt;br /&gt;
Notification about processing steps and failures&lt;br /&gt;
Upload results to XNat repository (at this stage results are uploaded into same folder where original scans are(*))&lt;br /&gt;
*** Immediate Plans&lt;br /&gt;
Complete Visual QC module&lt;br /&gt;
Design and implement meta-data transfer to XNat (including processing details and MRML files for loading images into the 3D Slicer)&lt;br /&gt;
&lt;br /&gt;
(*)Customization of results storage&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 6, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Tuned and debugged multiple subjects processing for: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat.&lt;br /&gt;
***Started working on quality control embedding into the above scenario. Plan to complete and video-record demo next week.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***Published general Product Integration scenario flow chart to collaborators' community. Discussion is open and in progress&lt;br /&gt;
&lt;br /&gt;
* October 30, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Piloted and tested the sequence: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat(1).&lt;br /&gt;
***Performance test of overall cycle: data transfer from remote serve is a bottleneck as expected&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data browsing features reviewed.&lt;br /&gt;
(1) Not automated yet&lt;br /&gt;
* October 23, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Defined COPD processing scenario with interoperability between Xnat, 3D Slicer Command Modules, Workflow, and Gridwizard Enterprise.&lt;br /&gt;
***Pilot version of Emphysema Measurements workflow pipeline deployed.&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data transfer features reviewed. Use account at XNat Central during learning curve.&lt;br /&gt;
***Feasibility test of 3D Slicer fiducials module for ROI highlights during QC and manual image processing activities. &lt;br /&gt;
* October 16, 2009&lt;br /&gt;
**Lung CT Scans Processing. Pilot project emerged. GenerateEmphysemaMeasurements module deployed as a webservice that submits jobs to computational cluster.&lt;br /&gt;
**EM Segmentation. Familiarized with GUI steps. Started working on automation steps outlining&lt;br /&gt;
**3D Slicer and XNat interaction. Got an overview from Wendy Plesniak.&lt;br /&gt;
* October 1 - 7, 2009&lt;br /&gt;
**Selected two first priority Projects: EM Segmentation of brain MRI images; Lung CT Scans Processing (COPD Study)&lt;br /&gt;
**Got initial outline of user requirements and design specs&lt;/div&gt;</summary>
		<author><name>Azaitsev</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=69565</id>
		<title>Projects:ARRA:SlicerWF</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=69565"/>
		<updated>2011-06-27T15:39:30Z</updated>

		<summary type="html">&lt;p&gt;Azaitsev: /* Progress */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Projects:ARRASuplements|Back to Slicer ARRA home page]]&lt;br /&gt;
= Aim =&lt;br /&gt;
Supplement 3D Slicer and Extensible Neuroimaging Archive Toolkit (XNAT) with workflow management system. Provide integration and interoperability between 3D Slicer, XNAT Services and 3-rd party image processing applications and high performance computing systems. Implement it as within currently developed Structural Planning and Implementation in Neurological Exploration (SPINE) System.&lt;br /&gt;
&lt;br /&gt;
= SPINE Project Documentation =&lt;br /&gt;
[http://cni.bwh.harvard.edu/projects/spine/index.html SPINE Docs]&lt;br /&gt;
&lt;br /&gt;
= Presentations =&lt;br /&gt;
* Segmentation Workflow. PECS University Social Cognition Study.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:SlicerWF_NAC_PECS_Workflow.pdf]]&lt;br /&gt;
* EAB10_ARRA Annual Progress Report Slides.&amp;lt;br&amp;gt;&lt;br /&gt;
[[media:EAB10_ARRA_WF_2011_Zaitsev.ppt | Service Oriented Solutions for 3D Slicer. EAB10_ARRA_WF_2011. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:EAB10_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:NAMIC_ARRA_WF_2011_Zaitsev.ppt  | NAMIC Annual Report 04/2010-03/2011. NAMIC_ARRA_WF_2011_Zaitsev. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:NAMIC_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:Slicer_WF_Slicer4CARMAWorkflow.ppt  | CARMA Workflow. Cardiac Ablation Followup. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:Slicer_WF_Slicer4CARMAWorkflow.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* CARMA Project Beta release Demo Location: http://cni29.bwh.harvard.edu/SlicerWFDemo/index.php&lt;br /&gt;
&lt;br /&gt;
* Segmentation Workflows: Screenshots, scans' and study description : [[File:SlicerWF_EMSegmentProjectsReview.zip]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
= All Hands Meeting Pages =&lt;br /&gt;
* Salt Lake City 2011 Winter [http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA SLC_2011_WorkFlow]&lt;br /&gt;
* MIT 2010 Summer [http://wiki.na-mic.org/Wiki/index.php/Summer_project_week_2010_Workflows_SOA MIT_2010_WorkFlow]&lt;br /&gt;
&lt;br /&gt;
= Research Plan =&lt;br /&gt;
*Create a stand-alone SPINE desktop agent with fully functional data exchange and communication mechanisms towards 3D Slicer and XNAT.&lt;br /&gt;
*Develop Service Oriented Architecture (SOA) SPINE System that will include 3D Slicer image processing modules deployed as web services as well as a workflow management system to orchestrate interaction between 3D Slicer, XNAT, and 3-rd party tools.&lt;br /&gt;
*Implement two-way control and communications between 3D Slicer and SPINE modules.&lt;br /&gt;
*Adapt SPINE System for cluster and grid computing scenarios.&lt;br /&gt;
*Provide with workflow and 3D Slicer web service wrappers editing tools.&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:UseCaseScenarios| Use Case scenarios]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PETCTWorkflow| PETCTWorkflow]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:AgingStudySegmentation| AgingStudySegmentation]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:TwoTensorTractography| TwoTensorTractography]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:LongitudinalMultimodalityRegistrationSuite| LongitudinalMultimodalityRegistrationSuite]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:MigrationJavaClients2QT| MigrationJavaClients2QT]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PediatricMSSegmentation| PediatricMSSegmentation]]&lt;br /&gt;
*[[DBP3:Utah:RegSegPipeline| MRI-based study and treatment of atrial fibrillation]]&lt;br /&gt;
&lt;br /&gt;
= Application Server / Workflow Engine Downloads =&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:WFEngineDownloads| Download Links]]&lt;br /&gt;
&lt;br /&gt;
=Key Personnel=&lt;br /&gt;
* Charles Gutmann, MD., 4%,  9-17-2009 through 9-16-2011&lt;br /&gt;
* Alexander Zaitsev, Ph.D., 75%, 9-17-2009 through 9-16-2011 &lt;br /&gt;
&lt;br /&gt;
=Annual Progress Statements =&lt;br /&gt;
'''2010-11''' &amp;lt;br&amp;gt;&lt;br /&gt;
The  April 2011 – March 2011 period was devoted on developing portable workflow solutions that can be deployed on end-users' workstations or notebooks with minimal or no system administration activities. This is in contrast to the server-side deployment. The following scenarios had been deployed and used for actual projects that require the following types of workflows: PET/CT registration and computation of biomarker driven brain physiological activities, Brain MRI Images segmentation,  MRI and MRI Angiography images pre-processing for cardiac ablation outcome estimation. Some  workflows (like EM Segmentation) had been utilizing various scenarios, some research projects  (like evaluation of chemotherapy outcome) require two types of workflows to assess physiological and structural changes. Starting from the 4th Quarter of 2011, the migration project had been emerged in order to embed Workflow GUIs into newly developed Slicer4 Suite. The existing rich client Java GUI applications are being re-written as C++/QT Sliceletts units, new modules (such as cardiac ablation project support) are had been written from scratch. The latter are being deployed from the Slicer4 GUI and act at a liaison between Slicer4 and Application Server containing  workflow and Slicer modules deployed as services. The feedback from the end users indicates that Workflow approach for the complex processing improves productivity, aids to the processing standardization and contributes to the overall experience using 3D Slicer&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
=Quarterly Progress=&lt;br /&gt;
&lt;br /&gt;
* NAMIC Annual Progress Slides (April 2010 - March 2011):&lt;br /&gt;
&lt;br /&gt;
* '''1st Qtr, 2011''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study: Second release is under testing by end-users. &lt;br /&gt;
*** Added MRI registration to aid ROI drawing on PET scans&lt;br /&gt;
*** Improved SUV results reporting and added flexibility to update ROI lookup table&lt;br /&gt;
*** Automated EM Segmentation of MRI images for computing SUVs for white matter, CSF, and whole brain (80% completion)&lt;br /&gt;
*** Integration with SPECTRE scull stripping module (70% completion) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** EM Segmentation: Automated WF Pipelines are created &amp;lt;br&amp;gt;&lt;br /&gt;
*** Flexible atlas selection (Pediatric, etc) feature added&lt;br /&gt;
*** Workflows implemented for EM Segmenter 3.6.2 and 3.6.3 (1st Qtr 2011 release)&lt;br /&gt;
&lt;br /&gt;
** Cardiac ablation results follow-up: Workflow for registration and ROI selection of cardiac MRI and MR Angiography &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Wrokflow and Web Services for prospective DTI tractography modules (currently written as Matlab modules at PNL) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Web Services for SPECTRE Scull stripping module&lt;br /&gt;
*** Accuracy and performance tuning&lt;br /&gt;
*** 50% completion&lt;br /&gt;
&lt;br /&gt;
** Migration Front End GUI to Slicer4/QT:&lt;br /&gt;
*** EM Segmentation&lt;br /&gt;
*** Cardiac Ablation Study&lt;br /&gt;
&lt;br /&gt;
** DICOM Uploader and Desktop Browser for XNat Image repository (alpha version - tested for MGH MS Center studies, proposed to use with MI2B2 Clients and Services)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''4th Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study and EM Segmentation for Aging Study are deployed at end-user sites and actively used for research. &lt;br /&gt;
** Adopted EM Segmentation preprocessing pipeline for HIV Study: high resolution SPGR images, integration with FreeSurfer brainmask extraction outputs; integration of Slicer SPECTRE module for brainmask extraction is in progress.&lt;br /&gt;
** The following post-release upgrades had been implemented based on end-user feedback: Application Server basic controls are performed from Rich Client GUI as alternative to traditional IT administration activities. The controls are implemented on point-and-click bases and include web services and workflow application deployment and upgrades, application server start and stop as well as warning end user when the server is not accepting request.&lt;br /&gt;
** Added DICOM downloads and results uploads of PET/CT pipelines from and to XNat Repository&lt;br /&gt;
** Created Services and Workflow for Matlab Prototypes modules. Case Study: tractography for DTI images&lt;br /&gt;
** Extended XNAT integration services:&lt;br /&gt;
*** Browsing capabilities of XNat data repository from the Workflow Applications&lt;br /&gt;
*** Improved DICOM upload and download performance&lt;br /&gt;
*** Added Metadata organizing services for uploaded DICOM images: header data extraction, image snapshots creation. &lt;br /&gt;
** Started project for Rich Client GUI migration from Java desktop application to build into SLicer4 QT modules. This affects mostly front-end GUI and has the following approaches: distribution with the Slicer4, end-user will select desired workflow application from Slicer4 menu while QT-written modules provide with the same functionality as Java Rich Clients. Case Study for the Migration process: registration suite for longitudinal studies that include multi-modality images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* '''3d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Concentrated on building downloadable workflow applications that could run both in desktop (new) and server environment, and that require minimum IT administrative resources. The desktop deployment is in compliance with Slicer3 general deployment concept.&lt;br /&gt;
*** The following use case scenario had been chosen: PET/CT image processing for longitudinal studies, EM Segmentation for longitudinal Aging Study.&lt;br /&gt;
** Released workflow application for PET/CT image processing for longitudinal studies. Provided end users with training and documentation.&lt;br /&gt;
*** The PET/CT processing workflow was designed to be a general application used whenever both structural patterns and metabolic activities are within the research scope. &lt;br /&gt;
*** The desktop version is tuned to use minimal computer resources, so the automates processing instances do not interfere with human activities. Automated activities may include, for example, registration and PET scan's standard uptake values computing, and manual human activities may include image cropping, quality control, and labeling voxels of interest.&lt;br /&gt;
** Core services and EM Segmentation preprocessing workflow was build for retrospective Aging Study. Tuned the Slicer3 webservices for processing low grade images acquired in mid 90s. Entire workflow is implemented with Slicer3 only modules and can be deployed locally and on the servers. Usage of Service Oriented Architecture (SOA) as a core technological approach allowed reusing most of the web services that had been build for PET/CT project. &lt;br /&gt;
** Continued embedding Slicer3 application and modules into previously released processing pipelines: replaced MIPAV with Slicer3 GUI for lesion assessment step in the multi-center Pediatric MS Cohort image processing &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''2d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Completed Social Cognition Workflow Implementation. This includes EM Segmetnation pre- and post-processing pipelines, data tracking, and integration with 3d party image processing utilities, as well as processing results acquired manually with Slicer GUI.  &lt;br /&gt;
** Multi-modality image registration and ROI selection/alignment workflow for longitudinal studies. &lt;br /&gt;
*** Use case: PET/CT image processing for longitudinal studies. &lt;br /&gt;
*** Build portable library of Slicer modules as web services and workflow that are deployed and run on a end-users' worksatations without utilization of SPL and other servers. The web services include novel Slicer3 modules, such as BRAINSFit and BRAINSResamle &lt;br /&gt;
*** Started working with Slicer3 developers on Slicer 3.8 GUI wizard to communicate with workflow instances.&lt;br /&gt;
** Participated at NA-MIC Summer 2010 Project Week: [[Summer_project_week_2010_Workflows_SOA]]&lt;br /&gt;
&lt;br /&gt;
=Progress=&lt;br /&gt;
*June 24, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
Project Week:&lt;br /&gt;
* Testing RSS module for left atrial wall scar segmentation&lt;br /&gt;
* Testing EM Segmenter for lesion detection on PD (requested by end-users) and FLAIR images&lt;br /&gt;
&lt;br /&gt;
EM Segmentation &lt;br /&gt;
* Web-based segmentation and registration module for MS Center. Goal: facilitate 3D SLicer modules for the cases that could not be processed with in-house build DTS+ algorithm&lt;br /&gt;
* Pipeline: Segment MPGR or T1 (user's choice), Register MPGR to PD/T2, Resample Segmentation Map to PD/T2. Completion: 60-70%.&lt;br /&gt;
* The rest will be done manually or via lesion segmentation with EM Segmenter.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* June 17, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
Preparation for Project Week&lt;br /&gt;
&lt;br /&gt;
* June 10, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
CARMA V.1.0&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code completed and tested&lt;br /&gt;
* Packaging as extension is pending (Subject for Summer 2011 Project week)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Debugging consolidation results issue(SUVs for manual and automated segmentation) &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* June 3, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Deployed on end-user's machine&lt;br /&gt;
* TODO next week: fix SUV results consolidation issue (when MRI segmented ROI got SUV computed for some subjects, only those subjects' SUVs are being added into consolidated report. &amp;quot;Raw&amp;quot; SUV values per subject are generated as expected)  &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 27, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Ready for deployment. New Features: hemispheres EM Segmentation, automated ICC/brainmask extraction using EM Segmenter, fixed controls for MRI conversion and registration&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 20, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General / PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Hemispheres EM Segmentation - adjusted for required label lookup table&lt;br /&gt;
* Use cases added for EM Segmenter General Project: http://www.slicer.org/slicerWiki/index.php/EMSegmenter-Tasks#EMSegmenter_use_cases&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SPECTRE Scull Stripping&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* The new version to be tested on coming week (After PETCT MRI processing migrated to Hemispheres scenario )&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* May 13, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General / PETCT V1.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Hemispheres EM Segmentation - technically works with labal values hardcoded in Slicer EM Segmenter - need to add manual label value edition step&lt;br /&gt;
* PETCT WF Cut for Java GUI (Pending Hemispheres label update completion). Next release will be in QT4.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* May 6, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (QA of EM Segmenter module, work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* April 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Open Discussion for Packaging WF QT Modules as Slicer4 extensions (waiting for SOPs)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review supported projects http://wiki.na-mic.org/Wiki/index.php/File:SlicerWF_EMSegmentProjectsReview.zip &lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (required by Study)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Slicer Modules General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Standardizing Crop Volumes Output (with A. Fedorov's module). Review for required updates of existing product (PET/CT, CARMA)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Open Discussion for Packaging WF QT Modules as Slicer4 extensions (waiting for SOPs)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review supported projects http://wiki.na-mic.org/Wiki/index.php/File:SlicerWF_EMSegmentProjectsReview.zip &lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (required by Study)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Slicer Modules General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Standardizing Crop Volumes Output (with A. Fedorov's module)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 22, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Beta release ready. Demo Location: http://cni29.bwh.harvard.edu/SlicerWFDemo/index.php&lt;br /&gt;
* TODO: Tutorial. Original inputs copy/renaming&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 15, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Adding App server auto-config features&lt;br /&gt;
* Finalizing the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 08, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Second release beta build tested on cosutmer side &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review registration quality (with Dr. Meier). Angiography images' Resampling tuned. &lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 01, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the second release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
XNat Integration&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* (Java) GUI for Project Browsing and DICOM Series Upload. Post-upload DICOM processing tested and debugged&amp;lt;br&amp;gt;&lt;br /&gt;
* Ready for integration with mi2b2 client.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Migrated to Latest Slicer 3.6.3 stable release: only the Input scene had to be updated, the API remained the same&lt;br /&gt;
* Tested EM Segmenter with CMTK4Slicer extension - processing takes to much time on Linux_64bit machine, rolled back to BRAINSFit registration. When used on Mac OS X build, the Slicer could not start (bug report 1126).&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SPECTRE Scull Stripping:&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Testes for various use cases: the module is extremely sensitive to T1 MRI quality (does not work for most MRIs from PET/CT project&lt;br /&gt;
* TODO next week: check for FLAIR images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Slicer4 QT GUI and Cropping activity in progress.&amp;lt;br&amp;gt;&lt;br /&gt;
* Tried direct MRA to MRA registration option: resampling with LMRI registration transforms works better.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Extra VOI labels revised&lt;br /&gt;
* Debugging of SUV results' renormalization step&lt;br /&gt;
* TODO: ICC extraction / whole brain total uptake computing; EM Segmentation for R_WM, L_WM SUV computing and BPH estimation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SCULL STRIPPING/SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Installed and tested CLI option on Linux_64bit platform&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Workflow interruption before BSPline registraton: BPEL Module completed. Slicer4 QT GUI and Cropping activity in prorgess.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Implemented and Tested with end-users proposed changes: denormalization of SUV results, adding more VOI labels, added FLAIR MRI in addition to T1s for VOI drawing&lt;br /&gt;
* Tested manual ICC extraction using PET scans: works satisfactory with island removal and cropping followed by threshold level labeling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4&lt;br /&gt;
* Change proposed: interrupt workflow after affine registration and have user crop the VOI. This is to prevent excessive deformations for BSpline registration and resampling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4. User has option to choose the atlas that fits better for the given subject (NOTE: hardcoding must be rewritten for atlas linking)&lt;br /&gt;
* PETCT test - the problem is that T1s are low resolution and with contrast. Proposed using T1s without contrast&lt;br /&gt;
* PETCT change request: users wants to compute SUV for entire ICC. Had demo how to segment brainmask/ICC using PET scan. The derived brainmask label can be used for SUV computation.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - cmpleted&lt;br /&gt;
* Sample cases run - excessive deformation after BSpline registration hase&lt;br /&gt;
* Next week plan - pull tuning controls to front-end of pipeline API, start working of QT module for CARMA registration&lt;br /&gt;
* May consider other than BRAINSFit registration modules&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Design plan for change request: more VOI labels, add FLAIR in addition to T1 for VOI drawing, T1s segmentation&lt;br /&gt;
* Tested segmentation for sample cases - artifacts from poor quality MRIs lead to exclusion of parts of ICC from segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Completed troubleshooting of EMSegmenter module calling from Java (need TCL libs to be pulled from Slicer environment)&lt;br /&gt;
* Tested EMSegmenter autoruns for HIV and Pediatric MS patiens. Work as expected, subject to improvement of PED MS case segmentation by building better skull/neck/air atalses&lt;br /&gt;
* Suggested usage of two subsets of atalases: with and without neck. The Subject MRIs have to be cropped accordingly or best fit atlas has to be selected&lt;br /&gt;
* Made no-neck cropped atlas collection for default EMSegmenter scenario&lt;br /&gt;
* Tested with PET/CT study MRI cases - see above &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - in progress&lt;br /&gt;
* Next week goal - have back end processing ready&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Longitudinal Study&lt;br /&gt;
* Added MRI registration to the pipeline&lt;br /&gt;
* Troubleshooting of complex XML schema issues on Linux machines (some modules working on MAC do not work on Linux). As a workaround - did not include MRI convert and register part into base BPEL module. Used separate services (transparent for end-user)&lt;br /&gt;
* TODO next week for change request completion: explicit pixel type casting for MRI in BRAINSFit, VOI MRML scene update (currently MRI added on top of schema)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* February 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipeline for Pediatric MRI. Same scenario as for HIV Project, icbm pediatric atlases (Completed, verified)&lt;br /&gt;
* Collected NIH healthy brain development atlases: various age ranges from 4.5 to 18 yo. Converted to Slicer readable format &lt;br /&gt;
* Work on web services for the new automated EM Segmenter module (release Nov 10 - current). Verified task completion both for adult and pediatric images. Discussed tuning parameters for work load balance on workstations.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Started working on MRI registration to the reference CT scans. &lt;br /&gt;
* Design specs for optional White Matter segmentation for SUV computing.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* February 4, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipelines for Pediatric MRI (in progress)&lt;br /&gt;
* Adapting Pediatric T1 atlases for &amp;quot;Human Brain&amp;quot; build-in EM Segmentation wizard (in progress)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 28, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Verifying EM Segmenter module for latest builds and HIV/PED MS Studies (report pending)&lt;br /&gt;
* Work with SPECTRE module developers with pediatric MRI brainmask extraction&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* January 21, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Compiling plan for WF FrontEnd GUI migration to Slicer4/QT Widgets&lt;br /&gt;
* Preparing for annual progress report&lt;br /&gt;
&lt;br /&gt;
* January 14, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI: Integrated into the Slicer4 as Slicelet (or thin Client)&lt;br /&gt;
* Participation at AHM-2011, discussing integration of SPECTRE module and updated approach to EM-Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA&lt;br /&gt;
&lt;br /&gt;
* January 7, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* HIV project workflow delivered. Major additions relate to user convenience: &lt;br /&gt;
- Project-specific parameter settings, importing T1s and brainmasks from FreeSurfer outputs with conversion to NIFTI, resampling brainmask to original scans and automatied subject addition.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Follow up with end user: need to add MRI scans, if available, addition and registration to CT in order to ease VOI drawings.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
 &lt;br /&gt;
* December 31, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Follow-up with user Experience for AGING Study Segmentation (Positive feedback)&lt;br /&gt;
* Target date for HIV project delivery - next week&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Self-training for QT widget development&amp;lt;br&amp;gt;&lt;br /&gt;
* Outlined Workflow Rich Clients migration strategy from Java to QT/Slicer4:&amp;lt;br&amp;gt;&lt;br /&gt;
** Use Java Stubs (similar to SPECTRE integration) or file binding for envocation of workflow pipelines. (See SOAP remark below)&lt;br /&gt;
** Direct Web Servisec calls must be wrapped into REST protocol. The reason: NON-commerchial QT kit does not include SOAP protocol for web servises.&lt;br /&gt;
** The GUI will be implemented as page widget or QT dialog GUI forms called from within Slicer4.&lt;br /&gt;
** Communications between Slicer4 and WF GUI will be set via child-parent and signal-slot relations&lt;br /&gt;
* Worked on a Prototype for Basic EM Segmentation QT widget (70% complete). Will work on integrtion with SLicer4 during the AHM-2010&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
XNAT Integration&lt;br /&gt;
* Debugged XNAT RESTFul API usage for uplaoding DICOM series followed by header data extraction and image snapshots creation&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Added compensation for failed atlas registration (subject for old poor quality pseudo-T1 images): blank probability maps are created in case of failure.&lt;br /&gt;
* Data preparation module for FreeSurfer data import near completion. Expected time for deployment at end-users workstations - first week of January&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Discussed strategy for EM Segmentation pipeline solutions collection (K. Pohl, R. Kikinis)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* RE-using the same core workflow as for 1-channel EM Segmentation of AGING STUDY cases&lt;br /&gt;
* Added data input preparation module: ICC label mask preparation and skull-stripping based on FreeSurfer brainmask output volume.&lt;br /&gt;
* Two-channel EM segmentation pipeline (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE / GENERAL Development &amp;lt;br&amp;gt;&lt;br /&gt;
* Worked on plans for migrating fro rich workflow Java clients to embedded workflow windows inside the Slicer.&amp;lt;br&amp;gt;&lt;br /&gt;
The embedded workflow management clients are to be implemented with QT/PyQT toolkits&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
INTEGRATION WITH XNAT:&amp;lt;br&amp;gt;&lt;br /&gt;
* Automated DICOM series upload with triggering DICOM headers parsing at XNat site (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress. &lt;br /&gt;
- Results upload to XNat (Completed) &amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat based on user's input (Project + Subject + PET or CT session / scan) (Completed)&amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat - perfomance boosting solution for downloads found , web services services are created, relinking for the client side in progress &amp;lt;br&amp;gt;&lt;br /&gt;
- Xnat querying for subjects and automated subject addition into the workflow (In Progress) &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-segmentation module added for auto correction of segmentation results. Particularly - relabeling CSF voxels segmented as Air inside the intracranial cavity. This was requested by end-users after processing images with zero-signals in CSF voxels &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting automated dual-echo DICOM images conversion and split into two NRRD volumes&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT / EM Segmentation pipeline:&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting memory allocation issues for scull-stripping module SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
COPD Project:&amp;lt;br&amp;gt;&lt;br /&gt;
* Benchmark test for accelerated DICOM downloads from XNat (remoote XNat Central server): we can handle at least 6 cases (4 CT scans in each) per hour, which is compatible with current workload quotes on SPL cluster processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* December 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Deployed Version 1. &amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Test project chosen as a closest match to registration scenario: Pediatric MS Cases from MGH - requires periodic image preview for different &lt;br /&gt;
modalities taken from vaious time points. Label maps for VOIs resampling is also required.&lt;br /&gt;
&lt;br /&gt;
* November 26, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user. Version 1 is complete&amp;lt;br&amp;gt;&lt;br /&gt;
* Started working on integration with XNat&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on input data organizing modules&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 19, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user (70% done)&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Universal Registration Workflow for Longitudinal Studies - design specs in progress&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 12, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Minor tuning to EM Segmentation template as of users' feedback&lt;br /&gt;
* Users started using the workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed input data conversion from Genesis to Slicer native or NIFTI format. Our help may be needed in input data organizing.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Tuned application according to co-laborators (PNL) needs&amp;lt;br&amp;gt;&lt;br /&gt;
* The webservices and BPEL workflow application are tested ready to accept computation requests from PNL case tracking system &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Discussed Universal Registration Workflow for Longitudinal Studies&lt;br /&gt;
* Started the thread about possible cooperation with Children hospital's image processing pipelines and integration with Xnat &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 5, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Webservices and workflow pilot project created and deployed on Psychiatry Neuroimaging Laboratory subnet &amp;lt;br&amp;gt;&lt;br /&gt;
* The V.1.0 deployment is scheduled for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 29, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Most of functionality is completed. Some volume statistics post processing is pending&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL EM SEGMENTATION Pipeline: &amp;lt;br&amp;gt;&lt;br /&gt;
* The SPECTRE scull stripping module. Started integration into EMS workflow. Made some test runs from Slicer GUI&amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Identified as a candidate for Workflow Application&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 22, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* All back-end functionality are implemented&amp;lt;br&amp;gt;&lt;br /&gt;
* EM Segmentation scene usability is confirmed by end-user&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for next week: add Label Statistics computation for CSF/Brain/ICC &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 15, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* The latest (October) builds of Slicer 3.6.2 produced acceptable results. This was verified by the target users. The EM Segmentation will be performed on Slicer 3.6.2 or later&amp;lt;br&amp;gt;&lt;br /&gt;
* The new Web services had been created and added to the pipeline as optional processing steps: Biasfield correction (implement novel N2ITKBiasFieldCorrection module) and Volume's scalar datatype casting (as workaround for Biasfield correction module not preserving image scalar datatype - the bug is filed) &amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed the Front-End GUI design with target users. The design pattern is taken from the PETCT project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 8, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-deployment support. Tuned CT registration as of user's feedback.&lt;br /&gt;
* Adapting to the Single Slicer build: Slicer 3.6.2. Found label duplicates in the label lookup table - will ask user if it's tolerable. Waiting for the Slicer 3.6.2 build that contains all required modules. Rolling back label tag appending code for SUVs - the latest Slicer build appends the tags.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Resumed development. The priorities are set for usage of Slicer 3.6.2 - subject for EM Segmentation scene tuning. Continued coding for Scene creation for Slicer 2.8 - as a backup option for ongoing research project.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 1, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized V1.0 release based on end-user feedback: updates relate mostly to error proofing and SUV values representation&lt;br /&gt;
* Post-deployment support. Users pre-processed first set of patients &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* September 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* System deployed and tested at End Users' site.&amp;lt;br&amp;gt;Users are trained to perform all tasks required by the workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
* Got positive feedback with suggestions on Slicer Scenes' layouts improvement and PET scans' SUV (standard uptake values) results display&lt;br /&gt;
* Two distribution packages are assembled: Lunix and MAC OS versions. The difference in two packages is in specific Slicer3.6/3.7 builds - subject to Slicer Linux builds debugging.&amp;lt;br&amp;gt; As a workaround for Linux deployment - multiple Slicer builds are used to perform various tasks (registration, opening editing scenes in Slicer, SUV computing)&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for coming week - finalize V1.0 release based on end-user feedback&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Embedded SUV computations into the workflow (as system calls - will be translated into web service later)&amp;lt;br&amp;gt;&lt;br /&gt;
* Pre-release demo for end users.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Create and debug EM Segmenter scenes template for Slicer 3.6 and 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* September 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation - workflow pipeline and deployment verified&amp;lt;br&amp;gt;&lt;br /&gt;
* Tested EM Segmentation scenes within Slicer 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
* Started migration of EM Segmentation to Slicer 3.6. Discovered issues had been reported to EM Segmenter module designers &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* August 29 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation completed. Preprocessing Pipleine completed 80% (subject for input registration parameters tuning) &amp;lt;br&amp;gt;&lt;br /&gt;
* Most webservices (for registration and resampling steps) had been taken and re-used from PET/CT ROI/Longitudinal Study - showing the advantage of service-oriented software design and deployment.&lt;br /&gt;
* Continued on distribution and deployment of the service/workflow applications: on PET/CT and AGING STUDY projects.&lt;br /&gt;
&lt;br /&gt;
PEDIATRIC Multiple Sclerosis Cohort. Support of multi-center distributed processing project&amp;lt;br&amp;gt;&lt;br /&gt;
* Introduced Slicer 3.6 for the MS Lesion Assessment step performed at Mayo Clinic. Images are being transferred from image repository at BWH and automatically opened and arranged within Slicer GUI for reading.  This was replacement of Client GUI using MIPAV that stopped working on new computers at Mayo Clinic.&lt;br /&gt;
The images are being loaded via generated MRML Scenes same way as in PET/CT and AGING STUDY projects &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* August 22 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Preprocessing pipeline merge with SUV computations &amp;lt;br&amp;gt;&lt;br /&gt;
- QA for SUVs computation was performed by Wendy Plesniak for images with known uptake values. &amp;lt;br&amp;gt;&lt;br /&gt;
- Discovered that image cropping step (not related to automated registration pipeline and SUVs computing) smoothes the images by doing interpolation when used with default settings. Got suggestions from Steve Piper using Nearest-Neighbor interpolation (&amp;quot;no interpolation&amp;quot;) for a time being&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
- This is the new project candidate. Requested for the images with failed manual segmentation and/or segmentation with FreeSurfer. The EM Segmentation run showed most acceptable results on one of the problem images back in February &amp;lt;br&amp;gt;&lt;br /&gt;
- The workflow will be developed and deployed similar to PET/CT ROI Longitudinal study approach - all preprocessing steps will be done with Slicer modules, all runs will be performed on local end-user machines.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
 &lt;br /&gt;
&lt;br /&gt;
* August 15 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- First 5 cases with 3-4 time points preprocessed for SUVs computation&lt;br /&gt;
&lt;br /&gt;
* August 8 2010&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Testing of installation and operation at users' site (Performed by Wendy Plesniak)&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* July 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Delivered beta version of registration pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
- Prepared installation and user manuals &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* June 11, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Registration modules completed &amp;lt;br&amp;gt;&lt;br /&gt;
- Irregular cases registration problem solved (when whole body and brain only scans are mixed for a timepoint)&amp;lt;br&amp;gt;&lt;br /&gt;
- Live demo of case setup and registration workflow for end users. Real case with 4 timepoints used&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Coming week plans&amp;lt;br&amp;gt;&lt;br /&gt;
- Adjust workflow based on end users' feedback&amp;lt;br&amp;gt;&lt;br /&gt;
- Integration with SUVs computing for PET scans&amp;lt;br&amp;gt;&lt;br /&gt;
- GUI for workflows dispatching and data organizing&amp;lt;br&amp;gt;&lt;br /&gt;
- (TBD) Integration with 4D time series analysis Slicer module&amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
* May 28, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- Migration to the latest Slicer 3.6 release candidate &amp;lt;br&amp;gt;&lt;br /&gt;
- Added webservice for new registration module: BRAINSFit &amp;lt;br&amp;gt;&lt;br /&gt;
- Test runs for new patients with 4 timepoints' scans &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Plans for next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI &amp;lt;br&amp;gt;&lt;br /&gt;
- processing workflow demo for end user &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 21, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Pilot version of portable web services and automated workflow tested: &amp;lt;br&amp;gt;&lt;br /&gt;
Linux: workflow and visual review passed&amp;lt;br&amp;gt;&lt;br /&gt;
Stress test for 25 timepoints passed &amp;lt;br&amp;gt;&lt;br /&gt;
MAC OS: workflow passed, visual review failing when PET/CT images are loaded into GUI simultaneously (bug report submitted)&amp;lt;br&amp;gt;&lt;br /&gt;
Windows: need to adapt command line modules and workflow management system to sygwin environment&amp;lt;br&amp;gt;&lt;br /&gt;
Plans for next week: integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI&lt;br /&gt;
&lt;br /&gt;
* May 7, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Selected registration and resampling modules with more precise and stable outputs. &amp;lt;br&amp;gt;&lt;br /&gt;
Started building portable web services and automated workflow &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 30, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- manual walk through the processing steps: ROI cropping, registration/resampling, PET pharmaceutical DICOM data retention. &amp;lt;br&amp;gt;&lt;br /&gt;
- testing workflow and web services packages distribution to end-users' machines&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* April 23, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : testing various registration and re-sampling algorithms (work in progress)&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation: as of collaborators' request, run existing EM Segmentation workflow for older low resolution pseudo-T1 images. The EM Segmentation works for those images with manual sampling. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 16, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
  Social Cognition Study: started Cortical Thickness Measurement module build (bases on NA-MIC ARCTIC pipeline) &amp;lt;br&amp;gt;&lt;br /&gt;
  PET/CT ROI/Longitudinal Study Registration : Design specs, PET-to-CT images registration tests on training data. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 9, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. GUI update based on end-user experience.&amp;lt;br&amp;gt;&lt;br /&gt;
User request: automated label maps' volumes calculation (Currently possible from Slicer3 GUI)&amp;lt;br&amp;gt; &lt;br /&gt;
PET/CT ROI Project. Initial design specs discussion with end-users and co-developers&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure&lt;br /&gt;
Verification of segmentation workflow GUI: from registering new case to reviewing results&amp;lt;br&amp;gt;&lt;br /&gt;
Cross study test of segmentation workflow: MGH/MS Center data - success,  HIV Project data - some EM Segmentation scene tuning is needed &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*&lt;br /&gt;
* April 2, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. Segmentation workflow completed&amp;lt;br&amp;gt;&lt;br /&gt;
* Coming Week plans:&amp;lt;br&amp;gt;&lt;br /&gt;
- Document Segmentation Workflow. Follow up with end users &amp;lt;br&amp;gt;&lt;br /&gt;
- Start with Cortical Thickness and ROI-in-longitudinal studies workflows&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* March 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All essential processing and workflow interaction clients are ready.&amp;lt;br&amp;gt;&lt;br /&gt;
- Completed segmentation for 10 out of 50 patients. The remaining cases will be finalized upon manual lesion segmentation and QC verification of WM/GM/CSF and Deep GM segmentation's. &amp;lt;br&amp;gt;&lt;br /&gt;
- TODO next week: refine QC GUI and data tracking / progress monitoring schema. &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&amp;lt;br&amp;gt;&lt;br /&gt;
- New Slicer3 web services added: re-slicing with reference image volume, casting image scalar type &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
* March 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Segmentation maps Merging Services for GM/WM/CSF (Slicer EM Segemnter), Lesion (Slicer, Manual), and Deep GM (FreeSurfer)  &amp;lt;br&amp;gt;&lt;br /&gt;
- Deep GM segmentation pipeline adopted as optional service for Social Cognition Study (22 out of 50 cases processed) &amp;lt;br&amp;gt;&lt;br /&gt;
- (In progress) GUI client for Launching Segmentation results merging with optional Deep GM segmentation with FreeSurfer &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- Complete GUI Client for Segmentation result merging &amp;lt;br&amp;gt;&lt;br /&gt;
- Progress Monitoring services for entire Study processing: EM Segmenter Preprocessing, EM Segmentation, Lesion Segmentation (including human activities assignments), Deep GM segmentation, and results consolidation. &amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* March 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All 50 cases went through &amp;quot;basic&amp;quot; One-channel EM segmentation (GM/WM/CSF) &amp;lt;br&amp;gt;&lt;br /&gt;
- Basic pipeline start-up command line client created: user has two options - request brainmask extraction or provide with previously extracted brainmask for a given subject &amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison of GM/WN/CSF performed for Slicer EM Segmenter and FreeSurfer recon-all (used with default settings). &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmenter provides more accurate output &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmentation pipeline runs faster (40 minutes vs 12 hrs when no brainmask extraction requested) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO:&amp;lt;br&amp;gt;&lt;br /&gt;
- merging modules for automatic 1-channel EM segmentation and manual lesion segmentation &amp;lt;br&amp;gt;&lt;br /&gt;
- Emerge Cortical Thickness pipeline project: use NAC ARCTIC processing steps and modules &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Selected stable EM Segmentation scenario: White Matter, Gray Matter, and Cerebrospinal Fluid &amp;lt;br&amp;gt;&lt;br /&gt;
- First 16 cases are segmented for selected scenario. Nine more cases are preprocessed for EM Segmentation.&amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison to segmentation with FreeSurfer showed better accuracy for Slicer2 EMSegmenter &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure &amp;lt;br&amp;gt;&lt;br /&gt;
- Three prerpcocessed cases failed during volume ICC masking with in-house build utility. Evaluated switching to Slicer3 Mask and island removing modules.&amp;lt;br&amp;gt;&lt;br /&gt;
- Initial design specs discussion for cortical thickness measurement pipeline. ARCTIC pipeline selected. ARCTIC preprocessing steps signifficantly overlap with EM Segmentation preprocessing workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
  &lt;br /&gt;
* February 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: &amp;lt;br&amp;gt;&lt;br /&gt;
A) parameters tuning for EM Segmenter itself (work with EM Segmenter developer), template scenes creation &amp;lt;br&amp;gt;&lt;br /&gt;
B) update preprocessing pipeline - deep gray matter atlases included &amp;lt;br&amp;gt;&lt;br /&gt;
C) test and debug preprocesing pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
D) identified missing modules: atlas autocalibration for EM Segmentation scene, Island removal for ICC mask&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- Review currently deployed modules. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: reviewed firts seven subjects' outputs, added volume orientation module into pipeline (prevents ICBM atlas linear registration failures)&amp;lt;br&amp;gt;&lt;br /&gt;
- Fused ICC(brainmask) extraction module with EM Segmenter preprocessing. Three scenarious implemented: start with pre-extracted ICC mask (longitudinal studies case), run with ICC ectration, run with ICC extraction AND ICC correction before ICBM atlas preporcessing. &amp;lt;br&amp;gt;&lt;br /&gt;
- Completion of Human activities GUI (QC, ICC Correction) planned for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: Volume Orientation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: automated preprocessing pipeline for Slicer2 EM Segmenter test version deployed. Seven cases pre-processed.&lt;br /&gt;
- PET Quantitative measurements: Preliminary design specs discussion.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: BSplineRegistration (for non-linear registration), ResampleVolume2 (for atlases resampling based on image atlase templates registration). Local and Network runs are implemented, Cluster/GridWizard implementation pending.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Slicer EM Segmenter module: preprocessing design for Slicer2 EM Segmenter&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Adapting for Slicer2 EM Segmenter (mostly from pipelines and services for previous projects)&lt;br /&gt;
  -- Integration with FreeSurfer modules for bisafield correction, brainmask extraction, and linear registration of ICBM atlases&lt;br /&gt;
  -- Preprocessing updates for non-linear registration of ICBM atlases with Slicer2 (image re-orientation service designed)&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 29, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- EM Segmentaton pipeline: preprocessing results are being transferred to XNat (anonymized data, Central XNat) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Slicer EM Segmenter module: discussed agenda and scheduled a work meeting for Social Cognition Study image segmentation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Testing stage, 95% completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- SPL XNat server: verified data exchange via RESTfull web services.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 22, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Follow up with White Matter Lesion Segmenter and Scull Stripping Modules developers: Work in Progress&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Work in Progress, 60%+ completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Discussed SPINE image repository migration to XNat&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 15, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. &lt;br /&gt;
- Social Cognition Study: &lt;br /&gt;
Work-in-progress on intermediate (reconstruction) and results (resources) data storage at XNat.&lt;br /&gt;
&amp;lt;br&amp;gt;Reviewing and preparation more cases for EM Segmentor (Slicer 3.5) tuning.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* NA-MIC Project Week&lt;br /&gt;
Selecting candidate Slicer modules for other than Lesion EM Segmentation topics of Social Cognition study: Withe Matter Lesion Segmenter (UNC), Scull Stripping utility from UIOWA.&lt;br /&gt;
Reviewing issues of currently used Scull Stripping Slicer Extension and Slicer 3.5 EM Segmenter.&lt;br /&gt;
&amp;lt;br&amp;gt;XNat Data organizing training&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 1, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Preparation of Demo for NA-MIC work week: &lt;br /&gt;
- COPD Study. Added Remote pipepline start interface (represents real world scenario where Xnat repository, Processing modules and User are at different sites)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
- EM Segmentation. Added human activities steps to the workflow: ICC (brainmask) correction and EM Segmantation scena load per se.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 25, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Pilot workflow pipeline for EM Segmentation (all steps except user-activity step: ICC correction assignment and tracking)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 18, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Build and tested web services for EM Segmentation image preprocessing: DICOM-to-NRRD conversion, registration, skull stripping, image masking.&lt;br /&gt;
Started building workflow pipeline (subject to finish first version next week)&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Started Collecting Library of Slicer Build number vs. functional modules and extensions.&lt;br /&gt;
Plan for NAMIC project week: scheduled meetings for XNat data customization, Skull-stripping modules tuning, identified Social Cognition study cases that fail EM Segmentation processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 11, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Updating and verification of EM Segmentation Scenario&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Projects:ARRA:SlicerWF:UseCaseScenarios#Usecase_MS_lesion_Assessment&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Familiarizing with Slicer3.4/5 Modules required for implementation of EM Segmentation Scenario. Participation in debugging and/or usage tuning of Dicom Conversion, Registration, Skull Stripping, Masking, and Image Casting modules. &lt;br /&gt;
&lt;br /&gt;
* December 4, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Slicer3.4's EM Segmentation and Visual QC as part of image processing pipeline for Social Cognition Study for MS Patients.&lt;br /&gt;
Project emerged. EM Segmentation template creation debugged.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
Emphysema Measurements (COPD Study) - workflow stability and scalability test.&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 27, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Emphysema Measurements (COPD Study).&lt;br /&gt;
Added compensation for long running calculations and time-outs to the main computing pipeline.&lt;br /&gt;
Visual QC (work in progress)&lt;br /&gt;
** Infrastructure&lt;br /&gt;
XNat data structure customization, metadata storage, results consolidation: new feature request list creation (work in progress)&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 13, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
*** Pilot system for whole processing cycle for Emphysema Measurements (COPD Study) including the following:&lt;br /&gt;
Web query for CT session file list download&lt;br /&gt;
Pilot user interface for submitting the file list and starting processing pipeline&lt;br /&gt;
Notification about processing steps and failures&lt;br /&gt;
Upload results to XNat repository (at this stage results are uploaded into same folder where original scans are(*))&lt;br /&gt;
*** Immediate Plans&lt;br /&gt;
Complete Visual QC module&lt;br /&gt;
Design and implement meta-data transfer to XNat (including processing details and MRML files for loading images into the 3D Slicer)&lt;br /&gt;
&lt;br /&gt;
(*)Customization of results storage&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 6, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Tuned and debugged multiple subjects processing for: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat.&lt;br /&gt;
***Started working on quality control embedding into the above scenario. Plan to complete and video-record demo next week.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***Published general Product Integration scenario flow chart to collaborators' community. Discussion is open and in progress&lt;br /&gt;
&lt;br /&gt;
* October 30, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Piloted and tested the sequence: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat(1).&lt;br /&gt;
***Performance test of overall cycle: data transfer from remote serve is a bottleneck as expected&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data browsing features reviewed.&lt;br /&gt;
(1) Not automated yet&lt;br /&gt;
* October 23, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Defined COPD processing scenario with interoperability between Xnat, 3D Slicer Command Modules, Workflow, and Gridwizard Enterprise.&lt;br /&gt;
***Pilot version of Emphysema Measurements workflow pipeline deployed.&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data transfer features reviewed. Use account at XNat Central during learning curve.&lt;br /&gt;
***Feasibility test of 3D Slicer fiducials module for ROI highlights during QC and manual image processing activities. &lt;br /&gt;
* October 16, 2009&lt;br /&gt;
**Lung CT Scans Processing. Pilot project emerged. GenerateEmphysemaMeasurements module deployed as a webservice that submits jobs to computational cluster.&lt;br /&gt;
**EM Segmentation. Familiarized with GUI steps. Started working on automation steps outlining&lt;br /&gt;
**3D Slicer and XNat interaction. Got an overview from Wendy Plesniak.&lt;br /&gt;
* October 1 - 7, 2009&lt;br /&gt;
**Selected two first priority Projects: EM Segmentation of brain MRI images; Lung CT Scans Processing (COPD Study)&lt;br /&gt;
**Got initial outline of user requirements and design specs&lt;/div&gt;</summary>
		<author><name>Azaitsev</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=Summer_project_week_2011_Workflows_SOA&amp;diff=69470</id>
		<title>Summer project week 2011 Workflows SOA</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=Summer_project_week_2011_Workflows_SOA&amp;diff=69470"/>
		<updated>2011-06-24T19:33:32Z</updated>

		<summary type="html">&lt;p&gt;Azaitsev: /* Key Investigators */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
Image:PW-MIT2011.png|[[2011_Summer_Project_Week#Projects|Projects List]]&lt;br /&gt;
Image:SlicerWF_LA_GUI.png|Left Atrium Ablation Follow-Up WF GUI&lt;br /&gt;
&amp;lt;/gallery&amp;gt;&lt;br /&gt;
&lt;br /&gt;
'''Workflows and Service Oriented Architecture Modules for Slicer4 as Extensions'''&lt;br /&gt;
&lt;br /&gt;
==Key Investigators==&lt;br /&gt;
* Brigham and Womens Hospital, Harvard Medical School: Alexander Zaitsev, Wendy Plesniak, Charles Guttmann, Ron Kikinis&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;margin: 20px;&amp;quot;&amp;gt;&lt;br /&gt;
&amp;lt;div style=&amp;quot;width: 27%; float: left; padding-right: 3%;&amp;quot;&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;h3&amp;gt;Objective&amp;lt;/h3&amp;gt;&lt;br /&gt;
&lt;br /&gt;
#:Thin clients for Slicer4 to support standardized workflows&lt;br /&gt;
#:&lt;br /&gt;
#:Automation of image processing steps, data management&lt;br /&gt;
#:&lt;br /&gt;
#:Combination of automated methods with human activities&lt;br /&gt;
#:Case Studies: Left Atrial Ablation follow-up, Brain PET/CT/MRI scans processing for cancer treatmen follow-up, brain atrophy estimation  &lt;br /&gt;
#:Major methods/algorithms used by workflows: Registration (BRAINSFit, BRAINSResample), Biasfield correction&lt;br /&gt;
&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;width: 27%; float: left; padding-right: 3%;&amp;quot;&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;h3&amp;gt;Approach, Plan&amp;lt;/h3&amp;gt;&lt;br /&gt;
#:Trying to build existing thin clients (Slicelets)  &lt;br /&gt;
#:as Slicer4 Extensions.&lt;br /&gt;
#:Add Left Atrium Ablation scar segmentation into the CARMA workflow (RSS or LA Segmenter?)&lt;br /&gt;
#:Incorporate MS Lesion EM Segmentation Scenario into the workflows  &lt;br /&gt;
&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;width: 40%; float: left;&amp;quot;&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;h3&amp;gt;Progress&amp;lt;/h3&amp;gt;&lt;br /&gt;
'''Slicer4 Extensions and Custom Builds:'''&lt;br /&gt;
&amp;lt;br&amp;gt; Learned how to do. Have to deal with package build for 32-bit Mac&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
'''CARMA workflow''':&amp;lt;br&amp;gt;&lt;br /&gt;
Gave several Life demos (including) general SOA/workflows approach. Identified ergonomic to be addressed in CARMA WF GUI &amp;lt;br&amp;gt;&lt;br /&gt;
Segmented hyperintencity regions at left atrium wall (RSS module). Issue: overestimation, need to add more thresholding controls to RSS.&amp;lt;br&amp;gt;&lt;br /&gt;
'''MS Lesion Segmentation'''&amp;lt;br&amp;gt;&lt;br /&gt;
Worked with EM Segmenter module builders on adult and pediatric cases segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
Lesion overestimation have to be addressed: can be done with manual correction&amp;lt;br&amp;gt;&lt;br /&gt;
Long running pre-processing steps make SOA/WF approach preferable for Lesion Segmentation &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
Image:SlicerWF_LA_Sample.png|Manual Segmentation Sample(Utah Team)&lt;br /&gt;
Image:SlicerWF_LA_RSS.png|RSS Segmentation Attempt &lt;br /&gt;
&amp;lt;/gallery&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;width: 97%; float: left;&amp;quot;&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA Winter_project_week_2011_Workflows_SOA]] Winter 2001 Project Week Page&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
[[http://www.na-mic.org/Wiki/index.php/DBP3:Utah Left Atrium Ablation Project, CARMA Wokflow]] CARMA Workflow Page&lt;br /&gt;
&lt;br /&gt;
[[http://wiki.na-mic.org/Wiki/index.php/DBP3:Utah:RegSegPipeline  CARMA Wokflow Preprocessing Pipeline]] CARMA Wokflow Preprocessing Pipeline&lt;br /&gt;
&lt;br /&gt;
==Delivery Mechanism==&lt;br /&gt;
&lt;br /&gt;
&amp;lt;!-- List here how you plan to deliver your results to user communities --&amp;gt;&lt;br /&gt;
&lt;br /&gt;
This work will be delivered to the NAMIC Kit as a &lt;br /&gt;
&lt;br /&gt;
##Built-in: &lt;br /&gt;
##Extension -- commandline:  &lt;br /&gt;
##Extension -- loadable:&lt;/div&gt;</summary>
		<author><name>Azaitsev</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=2011_Summer_Project_Week&amp;diff=69467</id>
		<title>2011 Summer Project Week</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=2011_Summer_Project_Week&amp;diff=69467"/>
		<updated>2011-06-24T18:03:28Z</updated>

		<summary type="html">&lt;p&gt;Azaitsev: /* Projects */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;  Back to [[Events]]&lt;br /&gt;
&lt;br /&gt;
[[image:PW-MIT2011.png|right|204px]]&lt;br /&gt;
&lt;br /&gt;
[[image:Panorama-summer-2011.png|left|thumb|200px|[http://360.io/Afjepd Interactive Panorama of Project Week] (Works on chrome, maybe not on other browsers)]]&lt;br /&gt;
[[image:Pano2summer2011namic.jpg|left|thumb|200px|[http://botview.appspot.com/viewer/pan0.swf?panoSrc=/media/4104002&amp;amp;FOV=52 Interactive Panorama of Project Week] (Needs flash)]]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
*'''Dates:''' June 20-24, 2011&lt;br /&gt;
*'''Location:''' MIT ([http://whereis.mit.edu/?go=34 Grier Rooms Location on MIT Campus Map])&lt;br /&gt;
&lt;br /&gt;
==Preliminary Agenda==&lt;br /&gt;
==Agenda==&lt;br /&gt;
&lt;br /&gt;
{|border=&amp;quot;1&amp;quot;&lt;br /&gt;
|-style=&amp;quot;background:#b0d5e6;color:#02186f&amp;quot; &lt;br /&gt;
!style=&amp;quot;width:10%&amp;quot; |Time&lt;br /&gt;
!style=&amp;quot;width:18%&amp;quot; |Monday, June 20&lt;br /&gt;
!style=&amp;quot;width:18%&amp;quot; |Tuesday, June 21&lt;br /&gt;
!style=&amp;quot;width:18%&amp;quot; |Wednesday, June 22&lt;br /&gt;
!style=&amp;quot;width:18%&amp;quot; |Thursday, June 23&lt;br /&gt;
!style=&amp;quot;width:18%&amp;quot; |Friday, June 24&lt;br /&gt;
|-&lt;br /&gt;
|&lt;br /&gt;
|bgcolor=&amp;quot;#dbdbdb&amp;quot;|'''Project Presentations'''&lt;br /&gt;
|bgcolor=&amp;quot;#6494ec&amp;quot;|'''NA-MIC Update Day'''&lt;br /&gt;
|&lt;br /&gt;
|bgcolor=&amp;quot;#88aaae&amp;quot;|'''IGT Day'''&lt;br /&gt;
|bgcolor=&amp;quot;#faedb6&amp;quot;|'''Reporting Day'''&lt;br /&gt;
|-&lt;br /&gt;
|bgcolor=&amp;quot;#ffffdd&amp;quot;|'''8:30am'''&lt;br /&gt;
|&lt;br /&gt;
|bgcolor=&amp;quot;#ffffaa&amp;quot;|Breakfast&lt;br /&gt;
|bgcolor=&amp;quot;#ffffaa&amp;quot;|Breakfast&lt;br /&gt;
|bgcolor=&amp;quot;#ffffaa&amp;quot;|Breakfast&lt;br /&gt;
|bgcolor=&amp;quot;#ffffaa&amp;quot;|Breakfast&lt;br /&gt;
|-&lt;br /&gt;
|bgcolor=&amp;quot;#ffffdd&amp;quot;|'''9am-12pm'''&lt;br /&gt;
|&lt;br /&gt;
|'''9am-10am:''' Slicer4 Extension (Writing Tutorial) ([[media:AHM-2011-SlicerExtensions.pdf|pdf]], [[media:AHM-2011-SlicerExtensions.ppt|ppt]]) (Jean-Christophe Fillion-Robin) &lt;br /&gt;
'''10-11am''' [[2011 Project Week Breakout Session: Slicer4|Slicer 4 Core Modules Usability Review]] (Continued) &amp;lt;br&amp;gt;&lt;br /&gt;
[[MIT_Project_Week_Rooms|Grier Room (Left)]] &lt;br /&gt;
&amp;lt;br&amp;gt;----------------------------------------&amp;lt;br&amp;gt;&lt;br /&gt;
'''11-12pm: &amp;lt;font color=&amp;quot;#4020ff&amp;quot;&amp;gt;Breakout Session:'''&amp;lt;/font&amp;gt; [[2011 Summer Project Week Breakout Session Slicer4 Annotation|Slicer4 Annotations]] (Nicole Aucoin)&amp;lt;br&amp;gt;&lt;br /&gt;
[[MIT_Project_Week_Rooms#Star|Star Room]]&lt;br /&gt;
|'''9am-12pm: &amp;lt;font color=&amp;quot;#4020ff&amp;quot;&amp;gt;Breakout Session:'''&amp;lt;/font&amp;gt;&amp;lt;br&amp;gt; [[2011 Project Week Breakout Session: ITK|ITK]] (Luis Ibanez)&lt;br /&gt;
&amp;lt;br&amp;gt;[[MIT_Project_Week_Rooms#Kiva_32-G449|Kiva Room]]&lt;br /&gt;
|'''9am-4pm: &amp;lt;font color=&amp;quot;#4020ff&amp;quot;&amp;gt;Breakout Session:'''&amp;lt;/font&amp;gt;&amp;lt;br&amp;gt; [[2011 Summer Project Week Breakout Session:OpenIGTLink|OpenIGTLink]]&lt;br /&gt;
&amp;lt;br&amp;gt;[[MIT_Project_Week_Rooms#Kiva_32-G449|Kiva Room]]&lt;br /&gt;
&amp;lt;br&amp;gt;'''10:30am-12pm: &amp;lt;font color=&amp;quot;#4020ff&amp;quot;&amp;gt;Breakout Session:'''&amp;lt;/font&amp;gt;&amp;lt;br&amp;gt; [[2011 Summer Project Week Breakout Session:DiffusionMRI|DiffusionMRI]]&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;[[MIT_Project_Week_Rooms#Star|Star Room]]&lt;br /&gt;
|'''10am-12pm:''' [[#Projects|Project Progress Updates]]&lt;br /&gt;
&amp;lt;br&amp;gt;[[MIT_Project_Week_Rooms#Grier_34-401_AB|Grier Rooms]]&lt;br /&gt;
|-&lt;br /&gt;
|bgcolor=&amp;quot;#ffffdd&amp;quot;|'''12pm-1pm'''&lt;br /&gt;
|bgcolor=&amp;quot;#ffffaa&amp;quot;|Lunch&lt;br /&gt;
|bgcolor=&amp;quot;#ffffaa&amp;quot;|Lunch&lt;br /&gt;
|bgcolor=&amp;quot;#ffffaa&amp;quot;|Lunch&lt;br /&gt;
|bgcolor=&amp;quot;#ffffaa&amp;quot;|Lunch&lt;br /&gt;
|bgcolor=&amp;quot;#ffffaa&amp;quot;|Lunch boxes; Adjourn by 1:30pm&lt;br /&gt;
|-&lt;br /&gt;
|bgcolor=&amp;quot;#ffffdd&amp;quot;|'''1pm-5:30pm'''&lt;br /&gt;
|'''1-1:05pm: &amp;lt;font color=&amp;quot;#503020&amp;quot;&amp;gt;Ron Kikinis: Welcome&amp;lt;/font&amp;gt;'''&lt;br /&gt;
[[MIT_Project_Week_Rooms#Grier_34-401_AB|Grier Rooms]]&lt;br /&gt;
&amp;lt;br&amp;gt;----------------------------------------&amp;lt;br&amp;gt;&lt;br /&gt;
'''1:05-3:30pm:''' [[#Projects|Project Introductions]] (all Project Leads)&lt;br /&gt;
&amp;lt;br&amp;gt;[[MIT_Project_Week_Rooms#Grier_34-401_AB|Grier Rooms]]&lt;br /&gt;
&amp;lt;br&amp;gt;----------------------------------------&amp;lt;br&amp;gt;&lt;br /&gt;
'''3:30-4:15pm''' Slicer4 Developers Guided Tour (Pieper) ([[media:2011 Summer-Slicer4.ppt|Slides]]). &amp;lt;br&amp;gt;&lt;br /&gt;
[[MIT_Project_Week_Rooms#Grier_34-401_AB|Grier Room (Left)]]&lt;br /&gt;
&amp;lt;br&amp;gt;---&amp;lt;br&amp;gt;&lt;br /&gt;
'''4:15-5:00pm''' [[2011 Project Week Breakout Session: Slicer4|Slicer 4 Core Modules Usability Review]] &amp;lt;br&amp;gt;&lt;br /&gt;
[[MIT_Project_Week_Rooms|Grier Room (Left)]] &lt;br /&gt;
&amp;lt;br&amp;gt;---&amp;lt;br&amp;gt;&lt;br /&gt;
'''4:15-5:00pm''' How to get DBP Data &amp;lt;br&amp;gt;&lt;br /&gt;
[[MIT_Project_Week_Rooms#Grier_34-401_AB|Grier Room (Right)]]&lt;br /&gt;
|'''1-3pm: &amp;lt;font color=&amp;quot;#4020ff&amp;quot;&amp;gt;Breakout Session:'''&amp;lt;/font&amp;gt;&amp;lt;br&amp;gt; [http://wiki.slicer.org/slicerWiki/index.php/Slicer4:MultiVolumeContainer#Summer_2011_Project_Week_Breakout_Session Slicer4 MultiVolume Containers] (Nicole Aucoin)&lt;br /&gt;
&amp;lt;br&amp;gt;[[MIT_Project_Week_Rooms#Grier_34-401_AB|Star Room]]&lt;br /&gt;
&amp;lt;br&amp;gt;----------------------------------------&amp;lt;br&amp;gt;&lt;br /&gt;
'''3-4pm:''' [[Summer_2011_Tutorial_Contest|Tutorial Contest Presentations]]&lt;br /&gt;
&amp;lt;br&amp;gt;[[MIT_Project_Week_Rooms#Grier_34-401_AB|Grier Rooms]]&lt;br /&gt;
&amp;lt;br&amp;gt;----------------------------------------&amp;lt;br&amp;gt;&lt;br /&gt;
'''4-5pm:''' [[2011 Summer Project Week Breakout Session VTKCharts|VTK Charts]] (Marcus Hanwell) ([[media:NA-MIC-VTK-Charts-2011.pdf|Slides]])&lt;br /&gt;
&amp;lt;br&amp;gt;[[MIT_Project_Week_Rooms#Grier_34-401_AB|Star Room]]&lt;br /&gt;
|'''12:45-1pm:''' [[Events:TutorialContestJune2011|Tutorial Contest Winner Announcement]]&lt;br /&gt;
&amp;lt;br&amp;gt;[[MIT_Project_Week_Rooms#Grier_34-401_AB|Grier Rooms]]&lt;br /&gt;
&amp;lt;br&amp;gt;----------------------------------------&amp;lt;br&amp;gt;&lt;br /&gt;
'''3-4pm: &amp;lt;font color=&amp;quot;#4020ff&amp;quot;&amp;gt;Breakout Session:'''&amp;lt;/font&amp;gt;&amp;lt;br&amp;gt;[[2011_Summer_Project_Week_Breakout_Session_EMRegistration|Inter-subject Registration for EM segmenter]]&lt;br /&gt;
&amp;lt;br&amp;gt;[[MIT_Project_Week_Rooms#Kiva_32-G449|Kiva Room]]&lt;br /&gt;
|'''1-4pm: &amp;lt;font color=&amp;quot;#4020ff&amp;quot;&amp;gt;Breakout Session:'''&amp;lt;/font&amp;gt;&amp;lt;br&amp;gt; [[2011 Summer Project Week Breakout Session:OpenIGTLink|OpenIGTLink]] &lt;br /&gt;
&amp;lt;br&amp;gt;[[MIT_Project_Week_Rooms#Kiva_32-G449|Kiva Room]]&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|bgcolor=&amp;quot;#ffffdd&amp;quot;|'''5:30pm'''&lt;br /&gt;
|bgcolor=&amp;quot;#f0e68b&amp;quot;|Adjourn for the day&lt;br /&gt;
|bgcolor=&amp;quot;#f0e68b&amp;quot;|Adjourn for the day&lt;br /&gt;
|bgcolor=&amp;quot;#f0e68b&amp;quot;|Adjourn for the day&lt;br /&gt;
|bgcolor=&amp;quot;#f0e68b&amp;quot;|Adjourn for the day&lt;br /&gt;
|&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
==Projects==&lt;br /&gt;
&lt;br /&gt;
* Please make a link for your project to a new page based on the [[2011_Summer_Project_Week_Template| 2011 Summer Project Page Template]]&lt;br /&gt;
&lt;br /&gt;
'''Neurosurgery, Brain and Spine, Traumatic Brain Injury'''&lt;br /&gt;
&lt;br /&gt;
#[[2011_Summer_Project_Week_Segmentation_TBI|Segmentation of Longitudinal TBI data]] (Bo Wang, Jack Van Horn, Andrei Irimia, Micah Chambers, Marcel Prastawa, Guido Gerig)&lt;br /&gt;
#[[Multimodality Image Registration for TBI]] (Yifei Lou, Danielle Pace, Jack Van Horn, Micah Chambers)&lt;br /&gt;
#[[2011_Summer_Project_Week_White_Matter_Laterality|White Matter Laterality in Python/Slicer4]] (Lauren O'Donnell)&lt;br /&gt;
#[[2011_Summer_Project_Week_Intraoperative_Brain_Shift_Monitor|Intraoperative Brain Shift Monitor]] (Jason White, Alex Golby, Steve Pieper, Junichi Tokuda)&lt;br /&gt;
#[[2011_Summer_Project_Week_GBM_Masks|Obtaining and Evaluation of Glioblastoma Multiforme (GBM) Segmentation Masks]] (Jan Egger,Tina Kapur, Andriy Fedorov, Rivka Colen, Ron Kikinis, Alex Golby, Christopher Nimsky)&lt;br /&gt;
#[[2011_Summer_Project_Week_NerveSeg|Segmentation of Nerve and Nerve Ganglia in the Spine]] (Adrian Dalca, Giovanna Danagoulian, Ron Kikinis, Ehud Schmidt, Polina Golland)&lt;br /&gt;
#[[2011_Summer_Project_Week_Spine_Segmentation_And_Osteoporosis_Screening_CT|Spine Segmentation &amp;amp; Osteoporosis Screening In CT Imaging Studies]] (Anthony Blumfield)&lt;br /&gt;
#[[2011_Summer_Project_Week_Quantitative_Magnetic_Susceptibility_Mapping|Quantitative Magnetic Susceptibility Mapping ]] (Clare Poynton)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
'''Radiation Therapy'''&lt;br /&gt;
#[[2011_Summer Project Week_Non-rigid_inter-patient_registration_of_bone_masks_derived_from_CT_for_Head_and_Neck_Cancer_Radiation_Therapy|Non-rigid, inter-patient registration of bone masks derived from CT for Head and Neck Cancer Radiation Therapy]] (Ivan Kolesov, Yi Gao, Gregory Sharp, Xiaodong Tao, Nadya Shusharina, Allen Tannenbaum)&lt;br /&gt;
#[[2011_Summer_Project_Week_Contouring_Gyne_Structures|Contouring of Anatomy Structures like Tumor, Bladder, Rectum and Sigmoid for Gynecological Brachytherapy]] (Tina Kapur, Akila Viswanathan, Jan Egger)&lt;br /&gt;
#[[2011_Summer_Project_Week_Slicer_DICOM_RT_Brachytherapy|Visualization of DICOM RT Planning Contours and Dose Distributions for Prostate and Gynecologic Brachytherapy in Slicer]] (Firdaus Janoos, Jan Egger, Greg Sharp, Andriy Fedorov, Tina Kapur)&lt;br /&gt;
#[[2011_Summer_Project__Week_DVH|Dose volume histograms in Slicer]] (Greg Sharp, Nadya Shusharina, Steve Pieper, Csaba Pinter, Tina Kapur)&lt;br /&gt;
#[[2011_Summer_Project__Week_DICOM_RT|Synthetic images, vector fields, RT structures and RT doses in Slicer and ITK]]. (Nadya Shusharina, Greg Sharp, Luis Ibanez, Steve Pieper)&lt;br /&gt;
&lt;br /&gt;
'''Huntington's Disease'''&lt;br /&gt;
#[[2011_Summer_Project_Week_Iowa_Huntington's_disease_data_sharing | Iowa Huntington's Disease Data Sharing]] (Hans Johnson, Mark Scully)&lt;br /&gt;
#[[2011_Summer_Project_Week_normal_consistency_particles|Normal consistency in particle correspondence computation using great circles in principal spheres - Huntington's Disease]], (Beatriz Paniagua, Martin Styner, Sungkyu Jung, Mark Scully)&lt;br /&gt;
#[[2011_Summer_Project__Week_Shape_Analysis_UNC |SPHARM &amp;amp; particles shape analysis - Huntington's Disease]] (Lucile Bompard, Clement Vachet, Beatriz Paniagua, Martin Styner&lt;br /&gt;
#[[2011_Summer_Project_Week_long_shape_regression|Longitudinal Shape Regression - Huntington's Disease]] (James Fishbaugh, Marcel Prastawa, Guido Gerig, Hans Johnson)&lt;br /&gt;
#[[2011_Summer_Project_Week_DTIPrep|DTIPrep - &amp;quot;Study-specific Protocol&amp;quot; based automatic DWI/DTI quality control and preparation]] - Huntington's Disease (Mahshid Farzinfar, Clement Vachet, Joy Matsui, Martin Styner)&lt;br /&gt;
#[[2011_Summer_Project_Week_DTI_PairWise_Registration|DTI pair-wise registration module]] - Huntington's Disease (Clement Vachet, Joy Matsui, Mark Scully, Martin Styner)&lt;br /&gt;
#[[2011_Summer_Project_Week_DTI analysis_for_Huntington's_disease | DTI analysis for Huntington's disease]] (Gopal Veni, Ross Whitaker)&lt;br /&gt;
&lt;br /&gt;
'''Atrial Fibrillation'''&lt;br /&gt;
#[[2011_Summer_Project_Week_RSS_for_AFib_Ablation|Robust Statistical Segmentation (RSS) for the Atrial Fibrillation Ablation Therapy]] (Yi Gao, Kedar Patwardhan, Steve Pieper, Wassim Haddad, and Allen Tannenbaum, Rob MacLeod, Josh Blauer, and Josh Cates)&lt;br /&gt;
#[[2011_Summer_Project_Week_Watersheds|Interactive Watersheds Segmentation Module for Slicer  for Atrial Fibrillation and HN Cancer]] (Josh Cates, Ross Whitaker, Steve Pieper, Jim Miller, Nadya)&lt;br /&gt;
&lt;br /&gt;
'''Device Integration with Slicer and General Image Guided Therapy'''&lt;br /&gt;
#[[2011_Summer_Project__Week_Wireless_Joystick|Wireless joystick controlling medical devices and software (e.g. Slicer4) in the operating room]] (Szymon Kostrzewski)&lt;br /&gt;
#[[2011_Summer_Project__Week_Live_Tracked_Ultrasound|Live Tracked Ultrasound with Slicer4 (Tamas Heffter)]]&lt;br /&gt;
#[http://wiki.na-mic.org/Wiki/index.php/Survey_stealthlink_openigtlink Surveying research teams interested in Open IGT Link support of Stealth Station (Nobuhiko Hata, Ron Kikinis)]&lt;br /&gt;
#[[2011_Summer_Project_Week_Needle_Detection_to_Control_Scanner_for_Prostate_Biopsy | Needle Detection to Control Scanner for Prostate Biopsy ]] (Atsushi Yamada, Loïc Cadour, Junichi Tokuda and Nobuhiko Hata)&lt;br /&gt;
#[[2011_Summer_Project_Week_Segementation_Reconstruction_Pericardial_Sac]] (Mohsen Mahvash, Noby Hata, Ron Kikinis)&lt;br /&gt;
#[[2011_Summer_Project_Week_4DUltrasound_HybridProbe_OsteoPlan|4D Ultrasound / Hybrid Probe / OsteoPlan]] (Laurent Chauvin, Noby Hata)&lt;br /&gt;
#[[2011_Summer_Project_Week_AMIGO|AMIGO]] (Mallika Winsor, Vivian He, Dan Kacher, Tina Kapur)&lt;br /&gt;
#[[2011_Summer_Project_Week_Patient_Mounted_Robot|Patient-mounted Robot Control using OpenIGTLink]] (Conor James Walsh, Maryam Shokri, Faye Wu)&lt;br /&gt;
#[[2011_Summer_project_Week_Open_Source_Electromagnetic_Trackers_using_OpenIGTLink|Open-source Electromagnetic Trackers using OpenIGTLink]] (Peter Traneus Anderson)&lt;br /&gt;
&lt;br /&gt;
'''General Segmentation'''&lt;br /&gt;
#[[2011_Summer_Project_Week_Integrate_BRAINSCut_into_Slicer3]](Regina Kim, ... )&lt;br /&gt;
#[[2011_Summer_Project_Week_EMSegmentation_in_3D_Slicer4|EM Segmentation in 3D Slicer 4]] (Daniel Haehn, Dominique Belhachemi, Kilian Pohl)&lt;br /&gt;
#[[2011_Summer_Project_Week_Customizing_EMSegmenter_pipelines_for_brain_lesions | Customizing EMSegmenter pipelines for brain lesions]] (Dominique Belhachemi, Alexander Zaitsev, Kilian Pohl)&lt;br /&gt;
#[[2011_Summer_Project_Week_Plastimatch_for_EMSegmenter | Integrating Plastimatch into the EMSegmenter]] (Dominique Belhachemi, Kilian Pohl, Greg Sharp, Daniel Haehn)&lt;br /&gt;
#[[2011_Summer_Project_Week_Slicer_Extension_for_GLISTR | Slicer extension for GLiome Image SegmenTation and Registration (GLISTR)]] (Andreas Schuh, Daniel Haehn, Kilian Pohl)&lt;br /&gt;
&lt;br /&gt;
'''General Registration'''&lt;br /&gt;
#[[2011_Summer_Project_Week__BRAINSFit_new_features_integration|Integrate new features into BRAINSFit]] (Andrey Fedorov, Hans Johnson, Mark Scully)&lt;br /&gt;
#[[2011_Summer_Project_Week__LANDWARP_integration|Integration of LANDWARP into interactive registration module]] (Andrey Fedorov, Greg Sharp, Nadya Shusharina)&lt;br /&gt;
#[[2011_Summer_Project_Week_Registration_of_mouse_brains|Registration of mouse brains]] (Francois Budin, Ipek Oguz, Martin Styner, Dominik Meier)&lt;br /&gt;
#[[NonRigidRegistrationThatAccommodatesResection|Demons Based Non-Rigid Registration that Accommodates Resection in 3D Slicer]] (Petter Risholm, Jim Miller, Sandy Wells)&lt;br /&gt;
#[[2011_Summer_Project_Week_SlidingOrganRegistrationFED|Integrate Fast Explicit Diffusion into Sliding Organ Registration module]] (Danielle Pace)&lt;br /&gt;
#[[2011_Summer_Project_Week_Image_Manifold_Learning_with_Spectral_Embedding_and_Laplacian_Eigenmaps|Image Manifold Learning with Spectral Embedding and Laplacian Eigenmaps]] (Ramesh Sridharan, Polina Golland)&lt;br /&gt;
&lt;br /&gt;
'''General Diffusion Tractography'''&lt;br /&gt;
#[[2011_Summer_Project_Week_WMGeometry_Slicer4 | White matter geometry measures in Slicer 4]] (Peter Savadjiev)&lt;br /&gt;
#[[2011_Summer_Project_Week_re-parameterize_fiber|Re-parametrize fiber tracts for fiber statistics analysis]] (Yundi Shi, Clement Vachet, Benjamin Yvernault, Anuja Sharma, Martin Styner)&lt;br /&gt;
#[[2011_Summer_Project_Week_ODF_though_Fiber_Counting | ODF computation through fiber counting]] (Yinpeng Li, Ipek Oguz, Martin Styner)&lt;br /&gt;
#[[2011_Summer_Project_Week_Nifti_Support_for_Diffusion_Tensor_Images|Nifti Support for Diffusion Tensor Images]] (Demian)&lt;br /&gt;
#[[2011_Summer_Project_Week_Finishing_details_on_the_workflows_DICOM_full_brain_tractography_peritumoral|Finishing details on the workflows: DICOM-&amp;gt;Full brain tractography / peritumoral]] (Demian)&lt;br /&gt;
#[[Summer_project_week_2011_Finsler_Streamlines|Adding streamlined tractography to the Finsler front propagation tractography toolkit]] (Antonio Tristán-Vega)&lt;br /&gt;
#[[2011_Summer_Project_Week_Slicer4_Tractography_Interaction_and_Display|Tractography Bundle/Cluster Interaction and Display in Slicer4]] (Isaiah Norton, Lauren O'Donnell, Demian Wasserman)&lt;br /&gt;
#[[2011_Summer_Project_Week_DTI_Volumetric_Tractography | DTI Volumetric Tractography]] (Steve Callahan, Mark Scully, Jim Miller)&lt;br /&gt;
#[[2011_Summer_Project_Week_DWI_Atlas | Slicer module for building an average population DWI Atlas]]  (Ryan Eckbo, Sylvain Bouix)&lt;br /&gt;
#[[2011_Summer_Project_Week_DTI_Volumetric_Segmentation_for_Group_studies | DTI Volumetric Segmentation for Group studies]] (Gopal Veni, Ross Whitaker)&lt;br /&gt;
&lt;br /&gt;
'''Vessels'''&lt;br /&gt;
#[[2011_Summer_Project_Week_SlicerVmtk4|The Vascular Modeling Toolkit in 3D Slicer 4]] (Daniel Haehn, Luca Antiga, Steve Pieper, Kilian Pohl, Ron Kikinis)	&lt;br /&gt;
#[[2011_Summer_Project__Week_Stenosis_Detector|Stenosis Detector in 3D Slicer 4]] (Suares Tamekue, Daniel Haehn, Luca Antiga, Ron Kikinis)&lt;br /&gt;
&lt;br /&gt;
'''Infrastructure'''&lt;br /&gt;
#[[2011_Summer_Project_Week_Annotation_Module|Annotation Module in Slicer4]] (Nicole Aucoin, Daniel Haehn)&lt;br /&gt;
#[[2011_Summer_Project_Week_RECIST|RECIST Slicer4 module]] (Nicole Aucoin)&lt;br /&gt;
#[[2011_Summer_Project_Week_Dicom2Nrrd|DicomToNrrdConverter refactoring]] ( Xiaodong Tao, Mark Scully)&lt;br /&gt;
#[[Summer_project_week_2011_Workflows_SOA|Workflows and Service Oriented Architecture Modules for Slicer4 as Extensions]] (Alexander Zaitsev, Wendy Plesniak, Charles Guttmann, Ron Kikinis)&lt;br /&gt;
#[[2011_Summer_Project__Week_DICOM_Networking|DICOM Networking interface for Slicer4]] (Steve Pieper, Nicole Aucoin, Noby Hata)&lt;br /&gt;
#[[2011_Summer_Project_Week_Automated_GUI_Testing| Automated GUI Testing (Sonia Pujol, Steve Pieper, Dave Partyka, Jean-Christophe Fillion-Robin, Xiaodong Tao)]]&lt;br /&gt;
#[[2011_Summer_Project_Week_FetchMI:_Slicer_integration_with_XNAT |FetchMI: Slicer integration with XNAT 1.5]] (Misha Milchenko, Wendy Plesniak)&lt;br /&gt;
#[[2011_Summer_Project_Week_Internationalization_of_Slicer|Internationalization of Slicer]] (Luping Fang, Steve Pieper, Daniel Haehn, Suares Tamekue, Jean-Christophe Fillion-Robin, Julien Finet, Yiming Ge, Ping Cao)&lt;br /&gt;
&lt;br /&gt;
==Background==&lt;br /&gt;
&lt;br /&gt;
We are pleased to announce the 13th PROJECT WEEK of hands-on research and development activity for applications in Image-Guided Therapy, Neuroscience, and several additional areas of biomedical research that enable personalized medicine. Participants will engage in open source programming using the [[NA-MIC-Kit|NA-MIC Kit]], algorithm design, medical imaging sequence development, tracking experiments, and clinical application. The main goal of this event is to move forward the translational research deliverables of the sponsoring centers and their collaborators. Active and potential collaborators are encouraged and welcome to attend this event. This event will be set up to maximize informal interaction between participants.  If you would like to learn more about this event, please [http://public.kitware.com/cgi-bin/mailman/listinfo/na-mic-project-week click here to join our mailing list].&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Active preparation begins on Thursday, April 28th at 3pm ET, with a kick-off teleconference.  Invitations to this call will be sent to members of the sponsoring communities, their collaborators, past attendees of the event, as well as any parties who have expressed an interest in working with these centers. The main goal of the kick-off call is to get an idea of which groups/projects will be active at the upcoming event, and to ensure that there is sufficient coverage for all. Subsequent teleconferences will allow for more focused discussions on individual projects and allow the hosts to finalize the project teams, consolidate any common components, and identify topics that should be discussed in breakout sessions. In the final days leading upto the meeting, all project teams will be asked to fill in a template page on this wiki that describes the objectives and plan of their projects.  &lt;br /&gt;
&lt;br /&gt;
The event itself will start off with a short presentation by each project team, driven using their previously created description, and will help all participants get acquainted with others who are doing similar work. In the rest of the week, about half the time will be spent in breakout discussions on topics of common interest of subsets of the attendees, and the other half will be spent in project teams, doing hands-on project work.  The hands-on activities will be done in 40-50 small teams of size 2-4, each with a mix of multi-disciplinary expertise.  To facilitate this work, a large room at MIT will be setup with several tables, with internet and power access, and each computer software development based team will gather on a table with their individual laptops, connect to the internet to download their software and data, and be able to work on their projects.  Teams working on projects that require the use of medical devices will proceed to Brigham and Women's Hospital and carry out their experiments there. On the last day of the event, a closing presentation session will be held in which each project team will present a summary of what they accomplished during the week.&lt;br /&gt;
&lt;br /&gt;
This event is part of the translational research efforts of [http://www.na-mic.org NA-MIC], [http://www.ncigt.org NCIGT], [http://nac.spl.harvard.edu/ NAC], [http://catalyst.harvard.edu/home.html Harvard Catalyst], and [http://www.cimit.org CIMIT].  It is an expansion of the NA-MIC Summer Project Week that has been held annually since 2005. It will be held every summer at MIT and Brigham and Womens Hospital in Boston, typically during the last full week of June, and in Salt Lake City in the winter, typically during the second week of January.  &lt;br /&gt;
&lt;br /&gt;
A summary of all past NA-MIC Project Events is available [[Project_Events#Past|here]].&lt;br /&gt;
&lt;br /&gt;
== Logistics ==&lt;br /&gt;
*'''Dates:''' June 20-24, 2011&lt;br /&gt;
*'''Location:''' MIT. [[Meeting_Locations:MIT_Grier_A_%26B|Grier Rooms A &amp;amp; B: 34-401A &amp;amp; 34-401B]].&lt;br /&gt;
*'''REGISTRATION:''' Please register [http://guest.cvent.com/d/sdqy0l/4W here].  Payment must be made by credit card.&lt;br /&gt;
*'''Registration Fee:''' $260 (covers the cost of breakfast, lunch and coffee breaks for the week). &lt;br /&gt;
*'''Hotel:''' Boston Marriott Cambridge, Two Cambridge Center, 50 Broadway, Cambridge, MA 02142.  Group rate is $199/night plus tax.  Book [http://www.marriott.com/hotels/travel/boscb?groupCode=jrbjrba&amp;amp;app=resvlink&amp;amp;fromDate=6/19/11&amp;amp;toDate=6/24/11 here] or call 1-617-494-6600 and mention that you are booking in the MIT Room Block.  '''All reservations must be made by May 29, 2011 to receive the discounted rate.'''&lt;br /&gt;
&lt;br /&gt;
== Preparation ==&lt;br /&gt;
&lt;br /&gt;
# Please make sure that you are on the http://public.kitware.com/cgi-bin/mailman/listinfo/na-mic-project-week mailing list&lt;br /&gt;
# The NA-MIC engineering team will be discussing infrastructure projects in a kickoff TCON on April 28, 3pm ET.  In the weeks following, new and old participants from the above mailing list will be invited to join to discuss their projects, so please make sure you are on it!&lt;br /&gt;
# By 3pm ET on Thursday May 12, all participants to add a one line title of their project to #Projects&lt;br /&gt;
#By 3pm ET on Thursday June 9, all project leads to complete [[Project_Week/Template|Complete a templated wiki page for your project]]. Please do not edit the template page itself, but create a new page for your project and cut-and-paste the text from this template page.  If you have questions, please send an email to tkapur at bwh.harvard.edu.&lt;br /&gt;
# By 3pm on June 16: Create a directory for each project on the [[Engineering:SandBox|NAMIC Sandbox]] (Zack)&lt;br /&gt;
## Commit on each sandbox directory the code examples/snippets that represent our first guesses of appropriate methods. (Luis and Steve will help with this, as needed)&lt;br /&gt;
## Gather test images in any of the Data sharing resources we have (e.g. XNAT/MIDAS). These ones don't have to be many. At least three different cases, so we can get an idea of the modality-specific characteristics of these images. Put the IDs of these data sets on the wiki page. (the participants must do this.)&lt;br /&gt;
## Setup nightly tests on a separate Dashboard, where we will run the methods that we are experimenting with. The test should post result images and computation time. (Zack)&lt;br /&gt;
# Please note that by the time we get to the project event, we should be trying to close off a project milestone rather than starting to work on one...&lt;br /&gt;
# People doing Slicer related projects should come to project week with slicer built on your laptop.&lt;br /&gt;
## Projects to develop extension modules should work with the [http://viewvc.slicer.org/viewcvs.cgi/branches/Slicer-3-6/#dirlist Slicer-3-6 branch] (new code should not be checked into the branch).&lt;br /&gt;
## Projects to modify core behavior of slicer should be done on the [http://viewvc.slicer.org/viewcvs.cgi/trunk/ trunk].&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
==Registrants==&lt;br /&gt;
&lt;br /&gt;
Do not add your name to this list- it is maintained by the organizers based on your paid registration (see Logistics for link)&lt;br /&gt;
#	Peter	Anderson,	Retired&lt;br /&gt;
#	Nicole	Aucoin,	Brigham and Women's Hospital&lt;br /&gt;
#	Dominique	Belhachemi,	University of Pennsylvania&lt;br /&gt;
#	Anthony	Blumfiled,	Radnostics&lt;br /&gt;
#	Lucile	Bompard,	UNC NIRAL&lt;br /&gt;
#	Sylvain	Bouix,	Brigham and Women's Hospital&lt;br /&gt;
#	Francois	Budin,	UNC NIRAL&lt;br /&gt;
#	Steve	Callahan,	University of Utah&lt;br /&gt;
#	Joshua	Cates,	University of Utah&lt;br /&gt;
#	Micah	Chambers,	Laboratory of NeuroImaging&lt;br /&gt;
#	Laurent	Chauvin,	Brigham and Women's Hospital&lt;br /&gt;
#	Rivka	Colen,	Brigham and Women's Hospital&lt;br /&gt;
#	Nikos	Chrisochoides,	Old Dominion University&lt;br /&gt;
#	Adrian	Dalca,	Massachusetts Institute of Technology&lt;br /&gt;
#	Manasi	Datar,	University of Utah&lt;br /&gt;
#	Colin	Davey	&lt;br /&gt;
#	Ryan	Eckbo,	Brigham and Women's Hospital&lt;br /&gt;
#	Jan	Egger,	University Hospital of Marburg&lt;br /&gt;
#	Luping	Fang,	Zhejiang University of Technology, China&lt;br /&gt;
#	Mahshid	Farzinfar,	University of North Carolina at Chapel Hill&lt;br /&gt;
#	Andriy	Fedorov,	Brigham and Women's Hospital&lt;br /&gt;
#	Jean-Christophe	Fillion-Robin,	Kitware, Inc.&lt;br /&gt;
#	Julien	Finet,	Kitware, Inc.&lt;br /&gt;
#	James	Fishbaugh,	University of Utah&lt;br /&gt;
#	Yi	Gao,	Georgia Institute of Technology&lt;br /&gt;
#	Greg	Gardner,	University of Utah&lt;br /&gt;
#	Ronen	Globinsky,	Yale University&lt;br /&gt;
# Randy Gollub, MGH&lt;br /&gt;
#	Maged	Goubran,	Robarts Research Institute&lt;br /&gt;
#	Vivian	He,	Brigham and Women's Hospital&lt;br /&gt;
#	Daniel	Haehn,	University of Pennsylvania&lt;br /&gt;
#	Mike	Halle,	Brigham and Women's Hospital&lt;br /&gt;
#	Marcus	Hanwell,	Kitware, Inc.&lt;br /&gt;
#	Noby	 Hata,	Brigham and Women's Hospital&lt;br /&gt;
#Katie Hayes, MGH&lt;br /&gt;
#	Tamas	Heffter,	Queen's University&lt;br /&gt;
#	Nicholas	Herlambang,	AZE, Ltd.&lt;br /&gt;
#	Firdaus	Janoos,	Brigham and Women's Hospital&lt;br /&gt;
#	Luis	Ibanez,	Kitware, Inc.&lt;br /&gt;
#	Andrei	Irimia,	University of California, Los Angeles&lt;br /&gt;
#	Hans	Johnson,	University of Iowa&lt;br /&gt;
#	Ilknur	Kabul,	Kitware, Inc.&lt;br /&gt;
#	Tina	Kapur,	Brigham and Women's Hospital&lt;br /&gt;
#	Peter	Karasev,	Georgia Institute of Technology&lt;br /&gt;
#	Ron	Kikinis,	Brigham and Women's Hospital&lt;br /&gt;
#	Regina	Kim,	University of Iowa&lt;br /&gt;
#	Ivan	Kolesov,	Georgia Institute of Technology&lt;br /&gt;
#	Szymon	Kostrzewski,	Ecole Polytechnique Federale de Lausanne EPFL&lt;br /&gt;
#	Dillon	Lee,	University of Utah&lt;br /&gt;
#	Yinpeng	Li,	UNC-NIRAL&lt;br /&gt;
#	Yifei	Lou,	Georgia Institute of Technology&lt;br /&gt;
#	Mohsen	Mahvash,	Harvard Medical School (BWH and VA)&lt;br /&gt;
#	Nikos	Makris,	Massachusetts General Hospital&lt;br /&gt;
#	Katie	Mastrogiacomo,	Brigham and Women's Hospital&lt;br /&gt;
#	Joy	Matsui,	University of Iowa&lt;br /&gt;
#	Dominik	Meier,	Brigham and Women's Hospital&lt;br /&gt;
#	Mikhail	Milchenko,	Washington University in St. Louis&lt;br /&gt;
#	James	Miller,	GE Research&lt;br /&gt;
#	Zach	Mullen,	Kitware, Inc.&lt;br /&gt;
#	Isaiah	Norton,	Brigham and Women's Hospital&lt;br /&gt;
#	Lauren	O'Donnell,	Brigham and Women's Hospital&lt;br /&gt;
#	Danielle	Pace,	Kitware, Inc.&lt;br /&gt;
#	Beatriz	Paniagua,	University of North Carolina at Chapel Hill&lt;br /&gt;
#	Xenophon	Papademetris,	Yale University&lt;br /&gt;
#	Kedar	Patwardhan,	GE Global Research&lt;br /&gt;
#	Steve	Pieper,	Isomics, Inc.&lt;br /&gt;
#	Csaba	Pinter,	Queen's University&lt;br /&gt;
#	Wendy	Plesniak,	Brigham and Women's Hospital&lt;br /&gt;
#Clare Poynton, MIT&lt;br /&gt;
#	Kilian	Pohl,	University of Pennsylvania&lt;br /&gt;
#	Marcel	Prastawa,	University of Utah&lt;br /&gt;
#	Sonia	Pujol,	Brigham and Women's Hospital&lt;br /&gt;
#	Martin	Rajchl,	Robarts Research Institute&lt;br /&gt;
#	Ramesh	Sridharan,	Massachusetts Institute of Technology&lt;br /&gt;
#	Petter	Risholm,	Brigham and Women's Hospital&lt;br /&gt;
#	Peter 	Savadjiev,	Brigham and Women's Hospital&lt;br /&gt;
#	Will	Schroeder,	Kitware, Inc.&lt;br /&gt;
#	Andreas	Schuh,	University of Pennsylvania&lt;br /&gt;
#	Mark	Scully,	University of Iowa&lt;br /&gt;
#	Gregory	Sharp,	Massachusetts General Hospital&lt;br /&gt;
#	Junichi	Tokuda,	Brigham and Women's Hospital&lt;br /&gt;
#	Yundi	Shi,	University of North Carolina at Chapel Hill&lt;br /&gt;
#	Matthew	Toews,	Brigham and Women's Hospital&lt;br /&gt;
#	Nadya	Shusharina,	Massachusetts General Hospital&lt;br /&gt;
#	Hao	Su,	Worcester Polytechnic Institute&lt;br /&gt;
#	Suares	Tamekue,	Brigham and Women's Hospital&lt;br /&gt;
#	Xiaodong	Tao,	GE Research&lt;br /&gt;
#	Clement	Vachet,	UNC Chapel Hill&lt;br /&gt;
#	Antonio	Vega,	Brigham and Women's Hospital&lt;br /&gt;
#	Gopal	Veni,	University of Utah&lt;br /&gt;
#	Bo	Wang,	University of Utah&lt;br /&gt;
#	Andrew	Wasam,	CoSMo Software Inc.&lt;br /&gt;
#	Demian	Wassermann,	Brigham and Women's Hospital&lt;br /&gt;
#	Sandy	Wells,	Brigham and Women's Hospital&lt;br /&gt;
#	Jason 	White,	Brigham and Women's Hospital&lt;br /&gt;
#	Mallika	Winsor,	Brigham and Women's Hospital&lt;br /&gt;
#	Atsushi	Yamada,	Brigham and Women's Hospital&lt;br /&gt;
#	Alexander	Yarmarkovich,	Isomics, Inc.&lt;br /&gt;
#	Alexander	Zaitsev,	Brigham and Women's Hospital&lt;br /&gt;
#	Ming	Zhao, Sun Yat-Sen University Cancer Center, GuangZhou, China&lt;/div&gt;</summary>
		<author><name>Azaitsev</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=Summer_project_week_2011_Workflows_SOA&amp;diff=69407</id>
		<title>Summer project week 2011 Workflows SOA</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=Summer_project_week_2011_Workflows_SOA&amp;diff=69407"/>
		<updated>2011-06-24T14:30:29Z</updated>

		<summary type="html">&lt;p&gt;Azaitsev: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
Image:PW-MIT2011.png|[[2011_Summer_Project_Week#Projects|Projects List]]&lt;br /&gt;
Image:SlicerWF_LA_GUI.png|Left Atrium Ablation Follow-Up WF GUI&lt;br /&gt;
&amp;lt;/gallery&amp;gt;&lt;br /&gt;
&lt;br /&gt;
'''Workflows and Service Oriented Architecture Modules for Slicer4 as Extensions'''&lt;br /&gt;
&lt;br /&gt;
==Key Investigators==&lt;br /&gt;
* Brigham and Womens Hospital, Harvard Medical School: Alexander Zaitsev, Wendy Plesniak, Charles Guttmann, Ron Kikinis&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;margin: 20px;&amp;quot;&amp;gt;&lt;br /&gt;
&amp;lt;div style=&amp;quot;width: 27%; float: left; padding-right: 3%;&amp;quot;&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;h3&amp;gt;Objective&amp;lt;/h3&amp;gt;&lt;br /&gt;
&lt;br /&gt;
#:Thin clients for Slicer4 to support standardized workflows&lt;br /&gt;
#:&lt;br /&gt;
#:Automation of image processing steps, data management&lt;br /&gt;
#:&lt;br /&gt;
#:Combination of automated methods with human activities&lt;br /&gt;
#:Case Studies: Left Atrial Ablation follow-up, Brain PET/CT/MRI scans processing for cancer treatmen follow-up, brain atrophy estimation  &lt;br /&gt;
#:Major methods/algorithms used by workflows: Registration (BRAINSFit, BRAINSResample), Biasfield correction&lt;br /&gt;
&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;width: 27%; float: left; padding-right: 3%;&amp;quot;&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;h3&amp;gt;Approach, Plan&amp;lt;/h3&amp;gt;&lt;br /&gt;
#:Trying to build existing thin clients (Slicelets)  &lt;br /&gt;
#:as Slicer4 Extensions.&lt;br /&gt;
#:Add Left Atrium Ablation scar segmentation into the CARMA workflow (RSS or LA Segmenter?)&lt;br /&gt;
#:Incorporate MS Lesion EM Segmentation Scenario into the workflows  &lt;br /&gt;
&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;width: 40%; float: left;&amp;quot;&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;h3&amp;gt;Progress&amp;lt;/h3&amp;gt;&lt;br /&gt;
'''Slicer4 Extensions and Custom Builds:'''&lt;br /&gt;
&amp;lt;br&amp;gt; Learned how to do. Have to deal with package build for 32-bit Mac&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
'''CARMA workflow''':&amp;lt;br&amp;gt;&lt;br /&gt;
Gave several Life demos (including) general SOA/workflows approach. Identified ergonomic to be addressed in CARMA WF GUI &amp;lt;br&amp;gt;&lt;br /&gt;
Segmented hyperintencity regions at left atrium wall (RSS module). Issue: overestimation, need to add more thresholding controls to RSS.&amp;lt;br&amp;gt;&lt;br /&gt;
'''MS Lesion Segmentation'''&amp;lt;br&amp;gt;&lt;br /&gt;
Worked with EM Segmenter module builders on adult and pediatric cases segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
Lesion overestimation have to be addressed: can be done with manual correction&amp;lt;br&amp;gt;&lt;br /&gt;
Long running pre-processing steps make SOA/WF approach preferable for Lesion Segmentation &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
Image:SlicerWF_LA_Sample.png|Manual Segmentation Sample(Utah Team)&lt;br /&gt;
Image:SlicerWF_LA_RSS.png|RSS Segmentation Attempt &lt;br /&gt;
&amp;lt;/gallery&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;width: 97%; float: left;&amp;quot;&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA Winter_project_week_2011_Workflows_SOA]] Winter 2001 Project Week Page&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
[[http://www.slicer.org/slicerWiki/index.php/Modules:RobustStatisticsSeg-Documentation-3.6 Left Atrium Ablation Project, CARMA Wokflow]] CARMA Workflow Page&lt;br /&gt;
&lt;br /&gt;
==Delivery Mechanism==&lt;br /&gt;
&lt;br /&gt;
&amp;lt;!-- List here how you plan to deliver your results to user communities --&amp;gt;&lt;br /&gt;
&lt;br /&gt;
This work will be delivered to the NAMIC Kit as a &lt;br /&gt;
&lt;br /&gt;
##Built-in: &lt;br /&gt;
##Extension -- commandline:  &lt;br /&gt;
##Extension -- loadable:&lt;/div&gt;</summary>
		<author><name>Azaitsev</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=File:SlicerWF_LA_GUI.png&amp;diff=69393</id>
		<title>File:SlicerWF LA GUI.png</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=File:SlicerWF_LA_GUI.png&amp;diff=69393"/>
		<updated>2011-06-24T14:24:46Z</updated>

		<summary type="html">&lt;p&gt;Azaitsev: Summer project week 2011&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Summer project week 2011&lt;/div&gt;</summary>
		<author><name>Azaitsev</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=File:SlicerWF_LA_RSS.png&amp;diff=69392</id>
		<title>File:SlicerWF LA RSS.png</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=File:SlicerWF_LA_RSS.png&amp;diff=69392"/>
		<updated>2011-06-24T14:23:58Z</updated>

		<summary type="html">&lt;p&gt;Azaitsev: Summer project week 2011&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Summer project week 2011&lt;/div&gt;</summary>
		<author><name>Azaitsev</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=File:SlicerWF_LA_Sample.png&amp;diff=69391</id>
		<title>File:SlicerWF LA Sample.png</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=File:SlicerWF_LA_Sample.png&amp;diff=69391"/>
		<updated>2011-06-24T14:23:09Z</updated>

		<summary type="html">&lt;p&gt;Azaitsev: Summer Project week 2011&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Summer Project week 2011&lt;/div&gt;</summary>
		<author><name>Azaitsev</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=Summer_project_week_2011_Workflows_SOA&amp;diff=69216</id>
		<title>Summer project week 2011 Workflows SOA</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=Summer_project_week_2011_Workflows_SOA&amp;diff=69216"/>
		<updated>2011-06-24T12:49:43Z</updated>

		<summary type="html">&lt;p&gt;Azaitsev: /* Key Investigators */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
Image:PW-MIT2011.png|[[2011_Summer_Project_Week#Projects|Projects List]]&lt;br /&gt;
Image:notfound.png|Interesting picture to be added... &lt;br /&gt;
&amp;lt;/gallery&amp;gt;&lt;br /&gt;
&lt;br /&gt;
'''Workflows and Service Oriented Architecture Modules for Slicer4 as Extensions'''&lt;br /&gt;
&lt;br /&gt;
==Key Investigators==&lt;br /&gt;
* Brigham and Womens Hospital, Harvard Medical School: Alexander Zaitsev, Wendy Plesniak, Charles Guttmann, Ron Kikinis&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;margin: 20px;&amp;quot;&amp;gt;&lt;br /&gt;
&amp;lt;div style=&amp;quot;width: 27%; float: left; padding-right: 3%;&amp;quot;&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;h3&amp;gt;Objective&amp;lt;/h3&amp;gt;&lt;br /&gt;
&lt;br /&gt;
#:Thin clients for Slicer4 to support standardized workflows&lt;br /&gt;
#:&lt;br /&gt;
#:Automation of image processing steps, data management&lt;br /&gt;
#:&lt;br /&gt;
#:Combination of automated methods with human activities&lt;br /&gt;
#:Case Studies: Left Atrial Ablation follow-up, Brain PET/CT/MRI scans processing for cancer treatmen follow-up, brain atrophy estimation  &lt;br /&gt;
#:Major methods/algorithms used by workflows: Registration (BRAINSFit, BRAINSResample), Biasfield correction&lt;br /&gt;
&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;width: 27%; float: left; padding-right: 3%;&amp;quot;&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;h3&amp;gt;Approach, Plan&amp;lt;/h3&amp;gt;&lt;br /&gt;
#:Trying to build existing thin clients (Slicelets)  &lt;br /&gt;
#:as Slicer4 Extensions.&lt;br /&gt;
#:Add Left Atrium Ablation scar segmentation into the CARMA workflow (RSS or LA Segmenter?)&lt;br /&gt;
#:Incorporate MS Lesion EM Segmentation Scenario into the workflows  &lt;br /&gt;
&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;width: 40%; float: left;&amp;quot;&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;h3&amp;gt;Progress&amp;lt;/h3&amp;gt;&lt;br /&gt;
'''Slicer4 Extensions and Custom Builds:'''&lt;br /&gt;
&amp;lt;br&amp;gt; Learned how to do. Have to deal with package build for 32-bit Mac&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
'''CARMA workflow''':&amp;lt;br&amp;gt;&lt;br /&gt;
Gave several Life demos (including) general SOA/workflows approach. Identified ergonomic to be addressed in CARMA WF GUI &amp;lt;br&amp;gt;&lt;br /&gt;
Segmented hyperintencity regions at left atrium wall (RSS module). Issue: overestimation, need to add more thresholding controls to RSS.&amp;lt;br&amp;gt;&lt;br /&gt;
'''MS Lesion Segmentation'''&amp;lt;br&amp;gt;&lt;br /&gt;
Worked with EM Segmenter module builders on adult and pediatric cases segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
Lesion overestimation have to be addressed: can be done with manual correction&amp;lt;br&amp;gt;&lt;br /&gt;
Long running pre-processing steps make SOA/WF approach preferable for Lesion Segmentation &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;width: 97%; float: left;&amp;quot;&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA Winter_project_week_2011_Workflows_SOA]] Winter 2001 Project Week Page&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
[[http://www.slicer.org/slicerWiki/index.php/Modules:RobustStatisticsSeg-Documentation-3.6 Left Atrium Ablation Project, CARMA Wokflow]] CARMA Workflow Page&lt;br /&gt;
&lt;br /&gt;
==Delivery Mechanism==&lt;br /&gt;
&lt;br /&gt;
&amp;lt;!-- List here how you plan to deliver your results to user communities --&amp;gt;&lt;br /&gt;
&lt;br /&gt;
This work will be delivered to the NAMIC Kit as a &lt;br /&gt;
&lt;br /&gt;
##Built-in: &lt;br /&gt;
##Extension -- commandline:  &lt;br /&gt;
##Extension -- loadable:&lt;/div&gt;</summary>
		<author><name>Azaitsev</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=Summer_project_week_2011_Workflows_SOA&amp;diff=68708</id>
		<title>Summer project week 2011 Workflows SOA</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=Summer_project_week_2011_Workflows_SOA&amp;diff=68708"/>
		<updated>2011-06-20T17:50:56Z</updated>

		<summary type="html">&lt;p&gt;Azaitsev: /* Key Investigators */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
Image:PW-MIT2011.png|[[2011_Summer_Project_Week#Projects|Projects List]]&lt;br /&gt;
Image:notfound.png|Interesting picture to be added... &lt;br /&gt;
&amp;lt;/gallery&amp;gt;&lt;br /&gt;
&lt;br /&gt;
'''Workflows and Service Oriented Architecture Modules for Slicer4 as Extensions'''&lt;br /&gt;
&lt;br /&gt;
==Key Investigators==&lt;br /&gt;
* Brigham and Womens Hospital, Harvard Medical School: Alexander Zaitsev, Wendy Plesniak, Charles Guttmann, Ron Kikinis&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;margin: 20px;&amp;quot;&amp;gt;&lt;br /&gt;
&amp;lt;div style=&amp;quot;width: 27%; float: left; padding-right: 3%;&amp;quot;&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;h3&amp;gt;Objective&amp;lt;/h3&amp;gt;&lt;br /&gt;
&lt;br /&gt;
#:Thin clients for Slicer4 to support standardized workflows&lt;br /&gt;
#:&lt;br /&gt;
#:Automation of image processing steps, data management&lt;br /&gt;
#:&lt;br /&gt;
#:Combination of automated methods with human activities&lt;br /&gt;
#:Case Studies: Left Atrial Ablation follow-up, Brain PET/CT/MRI scans processing for cancer treatmen follow-up, brain atrophy estimation  &lt;br /&gt;
#:Major methods/algorithms used by workflows: Registration (BRAINSFit, BRAINSResample), Biasfield correction&lt;br /&gt;
&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;width: 27%; float: left; padding-right: 3%;&amp;quot;&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;h3&amp;gt;Approach, Plan&amp;lt;/h3&amp;gt;&lt;br /&gt;
#:Trying to build existing thin clients (Slicelets)  &lt;br /&gt;
#:as Slicer4 Extensions.&lt;br /&gt;
#:Add Left Atrium Ablation scar segmentation into the CARMA workflow (RSS or LA Segmenter?)&lt;br /&gt;
#:Incorporate MS Lesion EM Segmentation Scenario into the workflows  &lt;br /&gt;
&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;width: 40%; float: left;&amp;quot;&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;h3&amp;gt;Progress&amp;lt;/h3&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;!-- Fill this out before Friday's summary presentations - list what you did and how well it worked. --&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;width: 97%; float: left;&amp;quot;&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA Winter_project_week_2011_Workflows_SOA]] Winter 2001 Project Week Page&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
[[http://www.slicer.org/slicerWiki/index.php/Modules:RobustStatisticsSeg-Documentation-3.6 Left Atrium Ablation Project, CARMA Wokflow]] CARMA Workflow Page&lt;br /&gt;
&lt;br /&gt;
==Delivery Mechanism==&lt;br /&gt;
&lt;br /&gt;
&amp;lt;!-- List here how you plan to deliver your results to user communities --&amp;gt;&lt;br /&gt;
&lt;br /&gt;
This work will be delivered to the NAMIC Kit as a &lt;br /&gt;
&lt;br /&gt;
##Built-in: &lt;br /&gt;
##Extension -- commandline:  &lt;br /&gt;
##Extension -- loadable:&lt;/div&gt;</summary>
		<author><name>Azaitsev</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=Summer_project_week_2011_Workflows_SOA&amp;diff=68441</id>
		<title>Summer project week 2011 Workflows SOA</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=Summer_project_week_2011_Workflows_SOA&amp;diff=68441"/>
		<updated>2011-06-17T21:03:58Z</updated>

		<summary type="html">&lt;p&gt;Azaitsev: /* Key Investigators */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
Image:PW-MIT2011.png|[[2011_Summer_Project_Week#Projects|Projects List]]&lt;br /&gt;
Image:notfound.png|Interesting picture to be added... &lt;br /&gt;
&amp;lt;/gallery&amp;gt;&lt;br /&gt;
&lt;br /&gt;
'''Workflows and Service Oriented Architecture Modules for Slicer4 as Extensions'''&lt;br /&gt;
&lt;br /&gt;
==Key Investigators==&lt;br /&gt;
* Brigham and Womens Hospital, Harvard Medical School: Alexander Zaitsev, Wendy Plesniak, Ron Kikini&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;margin: 20px;&amp;quot;&amp;gt;&lt;br /&gt;
&amp;lt;div style=&amp;quot;width: 27%; float: left; padding-right: 3%;&amp;quot;&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;h3&amp;gt;Objective&amp;lt;/h3&amp;gt;&lt;br /&gt;
&lt;br /&gt;
#:Thin clients for Slicer4 to support standardized workflows&lt;br /&gt;
#:&lt;br /&gt;
#:Automation of image processing steps, data management&lt;br /&gt;
#:&lt;br /&gt;
#:Combination of automated methods with human activities&lt;br /&gt;
#:Case Studies: Left Atrial Ablation follow-up, Brain PET/CT/MRI scans processing for cancer treatmen follow-up, brain atrophy estimation  &lt;br /&gt;
#:Major methods/algorithms used by workflows: Registration (BRAINSFit, BRAINSResample), Biasfield correction&lt;br /&gt;
&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;width: 27%; float: left; padding-right: 3%;&amp;quot;&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;h3&amp;gt;Approach, Plan&amp;lt;/h3&amp;gt;&lt;br /&gt;
#:Trying to build existing thin clients (Slicelets)  &lt;br /&gt;
#:as Slicer4 Extensions.&lt;br /&gt;
#:Add Left Atrium Ablation scar segmentation into the CARMA workflow&lt;br /&gt;
#:Incorporate MS Lesion EM Segmentation&lt;br /&gt;
#:Scenario into the workflows  &lt;br /&gt;
&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;width: 40%; float: left;&amp;quot;&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;h3&amp;gt;Progress&amp;lt;/h3&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;!-- Fill this out before Friday's summary presentations - list what you did and how well it worked. --&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;width: 97%; float: left;&amp;quot;&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA Winter_project_week_2011_Workflows_SOA]] Winter 2001 Project Week Page&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
[[http://www.slicer.org/slicerWiki/index.php/Modules:RobustStatisticsSeg-Documentation-3.6 Left Atrium Ablation Project, CARMA Wokflow]] CARMA Workflow Page&lt;br /&gt;
&lt;br /&gt;
==Delivery Mechanism==&lt;br /&gt;
&lt;br /&gt;
&amp;lt;!-- List here how you plan to deliver your results to user communities --&amp;gt;&lt;br /&gt;
&lt;br /&gt;
This work will be delivered to the NAMIC Kit as a &lt;br /&gt;
&lt;br /&gt;
##Built-in: &lt;br /&gt;
##Extension -- commandline:  &lt;br /&gt;
##Extension -- loadable:&lt;/div&gt;</summary>
		<author><name>Azaitsev</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=Summer_project_week_2011_Workflows_SOA&amp;diff=68440</id>
		<title>Summer project week 2011 Workflows SOA</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=Summer_project_week_2011_Workflows_SOA&amp;diff=68440"/>
		<updated>2011-06-17T21:03:43Z</updated>

		<summary type="html">&lt;p&gt;Azaitsev: /* Key Investigators */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
Image:PW-MIT2011.png|[[2011_Summer_Project_Week#Projects|Projects List]]&lt;br /&gt;
Image:notfound.png|Interesting picture to be added... &lt;br /&gt;
&amp;lt;/gallery&amp;gt;&lt;br /&gt;
&lt;br /&gt;
'''Workflows and Service Oriented Architecture Modules for Slicer4 as Extensions'''&lt;br /&gt;
&lt;br /&gt;
==Key Investigators==&lt;br /&gt;
* Brigham and Womens Hospital, Harvard Medical School: Alexander Zaitsev, Wendy Plesniak, Ron Kikini&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;margin: 20px;&amp;quot;&amp;gt;&lt;br /&gt;
&amp;lt;div style=&amp;quot;width: 27%; float: left; padding-right: 3%;&amp;quot;&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;h3&amp;gt;Objective&amp;lt;/h3&amp;gt;&lt;br /&gt;
&lt;br /&gt;
#:Thin clients for Slicer4 to support standardized workflows&lt;br /&gt;
#:&lt;br /&gt;
#:Automation of image processing steps, data management&lt;br /&gt;
#:&lt;br /&gt;
#:Combination of automated methods with human activities&lt;br /&gt;
#:Case Studies: Left Atrial Ablation follow-up, Brain PET/CT/MRI scans processing for cancer treatmen follow-up, brain atrophy estimation  &lt;br /&gt;
#:Major methods/algorithms used by workflows: Registration (BRAINSFit, BRAINSResample), Biasfield correction&lt;br /&gt;
&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;width: 27%; float: left; padding-right: 3%;&amp;quot;&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;h3&amp;gt;Approach, Plan&amp;lt;/h3&amp;gt;&lt;br /&gt;
#:Trying to build existing thin clients (Slicelets)  &lt;br /&gt;
#:as Slicer4 Extensions.&lt;br /&gt;
#:Add Left Atrium Ablation scar segmentation into the CARMA workflow&lt;br /&gt;
#:Incorporate MS Lesion EM Segmentation&lt;br /&gt;
#:Scenario into the workflows  &lt;br /&gt;
&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;width: 40%; float: left;&amp;quot;&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;h3&amp;gt;Progress&amp;lt;/h3&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;!-- Fill this out before Friday's summary presentations - list what you did and how well it worked. --&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;width: 97%; float: left;&amp;quot;&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA Winter_project_week_2011_Workflows_SOA]] Winter 2001 Project Week Page&lt;br /&gt;
&amp;lt;br&amp;gt;&amp;lt;/br&amp;gt;&lt;br /&gt;
[[http://www.slicer.org/slicerWiki/index.php/Modules:RobustStatisticsSeg-Documentation-3.6 Left Atrium Ablation Project, CARMA Wokflow]] CARMA Workflow Page&lt;br /&gt;
&lt;br /&gt;
==Delivery Mechanism==&lt;br /&gt;
&lt;br /&gt;
&amp;lt;!-- List here how you plan to deliver your results to user communities --&amp;gt;&lt;br /&gt;
&lt;br /&gt;
This work will be delivered to the NAMIC Kit as a &lt;br /&gt;
&lt;br /&gt;
##Built-in: &lt;br /&gt;
##Extension -- commandline:  &lt;br /&gt;
##Extension -- loadable:&lt;/div&gt;</summary>
		<author><name>Azaitsev</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=Summer_project_week_2011_Workflows_SOA&amp;diff=68439</id>
		<title>Summer project week 2011 Workflows SOA</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=Summer_project_week_2011_Workflows_SOA&amp;diff=68439"/>
		<updated>2011-06-17T21:03:15Z</updated>

		<summary type="html">&lt;p&gt;Azaitsev: /* Key Investigators */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
Image:PW-MIT2011.png|[[2011_Summer_Project_Week#Projects|Projects List]]&lt;br /&gt;
Image:notfound.png|Interesting picture to be added... &lt;br /&gt;
&amp;lt;/gallery&amp;gt;&lt;br /&gt;
&lt;br /&gt;
'''Workflows and Service Oriented Architecture Modules for Slicer4 as Extensions'''&lt;br /&gt;
&lt;br /&gt;
==Key Investigators==&lt;br /&gt;
* Brigham and Womens Hospital, Harvard Medical School: Alexander Zaitsev, Wendy Plesniak, Ron Kikini&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;margin: 20px;&amp;quot;&amp;gt;&lt;br /&gt;
&amp;lt;div style=&amp;quot;width: 27%; float: left; padding-right: 3%;&amp;quot;&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;h3&amp;gt;Objective&amp;lt;/h3&amp;gt;&lt;br /&gt;
&lt;br /&gt;
#:Thin clients for Slicer4 to support standardized workflows&lt;br /&gt;
#:&lt;br /&gt;
#:Automation of image processing steps, data management&lt;br /&gt;
#:&lt;br /&gt;
#:Combination of automated methods with human activities&lt;br /&gt;
#:Case Studies: Left Atrial Ablation follow-up, Brain PET/CT/MRI scans processing for cancer treatmen follow-up, brain atrophy estimation  &lt;br /&gt;
#:Major methods/algorithms used by workflows: Registration (BRAINSFit, BRAINSResample), Biasfield correction&lt;br /&gt;
&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;width: 27%; float: left; padding-right: 3%;&amp;quot;&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;h3&amp;gt;Approach, Plan&amp;lt;/h3&amp;gt;&lt;br /&gt;
#:Trying to build existing thin clients (Slicelets)  &lt;br /&gt;
#:as Slicer4 Extensions.&lt;br /&gt;
#:Add Left Atrium Ablation scar segmentation into the CARMA workflow&lt;br /&gt;
#:Incorporate MS Lesion EM Segmentation&lt;br /&gt;
#:Scenario into the workflows  &lt;br /&gt;
&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;width: 40%; float: left;&amp;quot;&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;h3&amp;gt;Progress&amp;lt;/h3&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;!-- Fill this out before Friday's summary presentations - list what you did and how well it worked. --&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;width: 97%; float: left;&amp;quot;&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA Winter_project_week_2011_Workflows_SOA]] Winter 2001 Project Week Page&lt;br /&gt;
[[http://www.slicer.org/slicerWiki/index.php/Modules:RobustStatisticsSeg-Documentation-3.6 Left Atrium Ablation Project, CARMA Wokflow]] CARMA Workflow Page&lt;br /&gt;
&lt;br /&gt;
==Delivery Mechanism==&lt;br /&gt;
&lt;br /&gt;
&amp;lt;!-- List here how you plan to deliver your results to user communities --&amp;gt;&lt;br /&gt;
&lt;br /&gt;
This work will be delivered to the NAMIC Kit as a &lt;br /&gt;
&lt;br /&gt;
##Built-in: &lt;br /&gt;
##Extension -- commandline:  &lt;br /&gt;
##Extension -- loadable:&lt;/div&gt;</summary>
		<author><name>Azaitsev</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=68183</id>
		<title>Projects:ARRA:SlicerWF</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=68183"/>
		<updated>2011-06-15T14:05:45Z</updated>

		<summary type="html">&lt;p&gt;Azaitsev: /* Progress */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Projects:ARRASuplements|Back to Slicer ARRA home page]]&lt;br /&gt;
= Aim =&lt;br /&gt;
Supplement 3D Slicer and Extensible Neuroimaging Archive Toolkit (XNAT) with workflow management system. Provide integration and interoperability between 3D Slicer, XNAT Services and 3-rd party image processing applications and high performance computing systems. Implement it as within currently developed Structural Planning and Implementation in Neurological Exploration (SPINE) System.&lt;br /&gt;
&lt;br /&gt;
= SPINE Project Documentation =&lt;br /&gt;
[http://cni.bwh.harvard.edu/projects/spine/index.html SPINE Docs]&lt;br /&gt;
&lt;br /&gt;
= Presentations =&lt;br /&gt;
* Segmentation Workflow. PECS University Social Cognition Study.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:SlicerWF_NAC_PECS_Workflow.pdf]]&lt;br /&gt;
* EAB10_ARRA Annual Progress Report Slides.&amp;lt;br&amp;gt;&lt;br /&gt;
[[media:EAB10_ARRA_WF_2011_Zaitsev.ppt | Service Oriented Solutions for 3D Slicer. EAB10_ARRA_WF_2011. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:EAB10_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:NAMIC_ARRA_WF_2011_Zaitsev.ppt  | NAMIC Annual Report 04/2010-03/2011. NAMIC_ARRA_WF_2011_Zaitsev. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:NAMIC_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:Slicer_WF_Slicer4CARMAWorkflow.ppt  | CARMA Workflow. Cardiac Ablation Followup. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:Slicer_WF_Slicer4CARMAWorkflow.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* CARMA Project Beta release Demo Location: http://cni29.bwh.harvard.edu/SlicerWFDemo/index.php&lt;br /&gt;
&lt;br /&gt;
* Segmentation Workflows: Screenshots, scans' and study description : [[File:SlicerWF_EMSegmentProjectsReview.zip]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
= All Hands Meeting Pages =&lt;br /&gt;
* Salt Lake City 2011 Winter [http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA SLC_2011_WorkFlow]&lt;br /&gt;
* MIT 2010 Summer [http://wiki.na-mic.org/Wiki/index.php/Summer_project_week_2010_Workflows_SOA MIT_2010_WorkFlow]&lt;br /&gt;
&lt;br /&gt;
= Research Plan =&lt;br /&gt;
*Create a stand-alone SPINE desktop agent with fully functional data exchange and communication mechanisms towards 3D Slicer and XNAT.&lt;br /&gt;
*Develop Service Oriented Architecture (SOA) SPINE System that will include 3D Slicer image processing modules deployed as web services as well as a workflow management system to orchestrate interaction between 3D Slicer, XNAT, and 3-rd party tools.&lt;br /&gt;
*Implement two-way control and communications between 3D Slicer and SPINE modules.&lt;br /&gt;
*Adapt SPINE System for cluster and grid computing scenarios.&lt;br /&gt;
*Provide with workflow and 3D Slicer web service wrappers editing tools.&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:UseCaseScenarios| Use Case scenarios]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PETCTWorkflow| PETCTWorkflow]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:AgingStudySegmentation| AgingStudySegmentation]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:TwoTensorTractography| TwoTensorTractography]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:LongitudinalMultimodalityRegistrationSuite| LongitudinalMultimodalityRegistrationSuite]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:MigrationJavaClients2QT| MigrationJavaClients2QT]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PediatricMSSegmentation| PediatricMSSegmentation]]&lt;br /&gt;
*[[DBP3:Utah:RegSegPipeline| MRI-based study and treatment of atrial fibrillation]]&lt;br /&gt;
&lt;br /&gt;
= Application Server / Workflow Engine Downloads =&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:WFEngineDownloads| Download Links]]&lt;br /&gt;
&lt;br /&gt;
=Key Personnel=&lt;br /&gt;
* Charles Gutmann, MD., 4%,  9-17-2009 through 9-16-2011&lt;br /&gt;
* Alexander Zaitsev, Ph.D., 75%, 9-17-2009 through 9-16-2011 &lt;br /&gt;
&lt;br /&gt;
=Annual Progress Statements =&lt;br /&gt;
'''2010-11''' &amp;lt;br&amp;gt;&lt;br /&gt;
The  April 2011 – March 2011 period was devoted on developing portable workflow solutions that can be deployed on end-users' workstations or notebooks with minimal or no system administration activities. This is in contrast to the server-side deployment. The following scenarios had been deployed and used for actual projects that require the following types of workflows: PET/CT registration and computation of biomarker driven brain physiological activities, Brain MRI Images segmentation,  MRI and MRI Angiography images pre-processing for cardiac ablation outcome estimation. Some  workflows (like EM Segmentation) had been utilizing various scenarios, some research projects  (like evaluation of chemotherapy outcome) require two types of workflows to assess physiological and structural changes. Starting from the 4th Quarter of 2011, the migration project had been emerged in order to embed Workflow GUIs into newly developed Slicer4 Suite. The existing rich client Java GUI applications are being re-written as C++/QT Sliceletts units, new modules (such as cardiac ablation project support) are had been written from scratch. The latter are being deployed from the Slicer4 GUI and act at a liaison between Slicer4 and Application Server containing  workflow and Slicer modules deployed as services. The feedback from the end users indicates that Workflow approach for the complex processing improves productivity, aids to the processing standardization and contributes to the overall experience using 3D Slicer&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
=Quarterly Progress=&lt;br /&gt;
&lt;br /&gt;
* NAMIC Annual Progress Slides (April 2010 - March 2011):&lt;br /&gt;
&lt;br /&gt;
* '''1st Qtr, 2011''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study: Second release is under testing by end-users. &lt;br /&gt;
*** Added MRI registration to aid ROI drawing on PET scans&lt;br /&gt;
*** Improved SUV results reporting and added flexibility to update ROI lookup table&lt;br /&gt;
*** Automated EM Segmentation of MRI images for computing SUVs for white matter, CSF, and whole brain (80% completion)&lt;br /&gt;
*** Integration with SPECTRE scull stripping module (70% completion) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** EM Segmentation: Automated WF Pipelines are created &amp;lt;br&amp;gt;&lt;br /&gt;
*** Flexible atlas selection (Pediatric, etc) feature added&lt;br /&gt;
*** Workflows implemented for EM Segmenter 3.6.2 and 3.6.3 (1st Qtr 2011 release)&lt;br /&gt;
&lt;br /&gt;
** Cardiac ablation results follow-up: Workflow for registration and ROI selection of cardiac MRI and MR Angiography &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Wrokflow and Web Services for prospective DTI tractography modules (currently written as Matlab modules at PNL) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Web Services for SPECTRE Scull stripping module&lt;br /&gt;
*** Accuracy and performance tuning&lt;br /&gt;
*** 50% completion&lt;br /&gt;
&lt;br /&gt;
** Migration Front End GUI to Slicer4/QT:&lt;br /&gt;
*** EM Segmentation&lt;br /&gt;
*** Cardiac Ablation Study&lt;br /&gt;
&lt;br /&gt;
** DICOM Uploader and Desktop Browser for XNat Image repository (alpha version - tested for MGH MS Center studies, proposed to use with MI2B2 Clients and Services)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''4th Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study and EM Segmentation for Aging Study are deployed at end-user sites and actively used for research. &lt;br /&gt;
** Adopted EM Segmentation preprocessing pipeline for HIV Study: high resolution SPGR images, integration with FreeSurfer brainmask extraction outputs; integration of Slicer SPECTRE module for brainmask extraction is in progress.&lt;br /&gt;
** The following post-release upgrades had been implemented based on end-user feedback: Application Server basic controls are performed from Rich Client GUI as alternative to traditional IT administration activities. The controls are implemented on point-and-click bases and include web services and workflow application deployment and upgrades, application server start and stop as well as warning end user when the server is not accepting request.&lt;br /&gt;
** Added DICOM downloads and results uploads of PET/CT pipelines from and to XNat Repository&lt;br /&gt;
** Created Services and Workflow for Matlab Prototypes modules. Case Study: tractography for DTI images&lt;br /&gt;
** Extended XNAT integration services:&lt;br /&gt;
*** Browsing capabilities of XNat data repository from the Workflow Applications&lt;br /&gt;
*** Improved DICOM upload and download performance&lt;br /&gt;
*** Added Metadata organizing services for uploaded DICOM images: header data extraction, image snapshots creation. &lt;br /&gt;
** Started project for Rich Client GUI migration from Java desktop application to build into SLicer4 QT modules. This affects mostly front-end GUI and has the following approaches: distribution with the Slicer4, end-user will select desired workflow application from Slicer4 menu while QT-written modules provide with the same functionality as Java Rich Clients. Case Study for the Migration process: registration suite for longitudinal studies that include multi-modality images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* '''3d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Concentrated on building downloadable workflow applications that could run both in desktop (new) and server environment, and that require minimum IT administrative resources. The desktop deployment is in compliance with Slicer3 general deployment concept.&lt;br /&gt;
*** The following use case scenario had been chosen: PET/CT image processing for longitudinal studies, EM Segmentation for longitudinal Aging Study.&lt;br /&gt;
** Released workflow application for PET/CT image processing for longitudinal studies. Provided end users with training and documentation.&lt;br /&gt;
*** The PET/CT processing workflow was designed to be a general application used whenever both structural patterns and metabolic activities are within the research scope. &lt;br /&gt;
*** The desktop version is tuned to use minimal computer resources, so the automates processing instances do not interfere with human activities. Automated activities may include, for example, registration and PET scan's standard uptake values computing, and manual human activities may include image cropping, quality control, and labeling voxels of interest.&lt;br /&gt;
** Core services and EM Segmentation preprocessing workflow was build for retrospective Aging Study. Tuned the Slicer3 webservices for processing low grade images acquired in mid 90s. Entire workflow is implemented with Slicer3 only modules and can be deployed locally and on the servers. Usage of Service Oriented Architecture (SOA) as a core technological approach allowed reusing most of the web services that had been build for PET/CT project. &lt;br /&gt;
** Continued embedding Slicer3 application and modules into previously released processing pipelines: replaced MIPAV with Slicer3 GUI for lesion assessment step in the multi-center Pediatric MS Cohort image processing &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''2d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Completed Social Cognition Workflow Implementation. This includes EM Segmetnation pre- and post-processing pipelines, data tracking, and integration with 3d party image processing utilities, as well as processing results acquired manually with Slicer GUI.  &lt;br /&gt;
** Multi-modality image registration and ROI selection/alignment workflow for longitudinal studies. &lt;br /&gt;
*** Use case: PET/CT image processing for longitudinal studies. &lt;br /&gt;
*** Build portable library of Slicer modules as web services and workflow that are deployed and run on a end-users' worksatations without utilization of SPL and other servers. The web services include novel Slicer3 modules, such as BRAINSFit and BRAINSResamle &lt;br /&gt;
*** Started working with Slicer3 developers on Slicer 3.8 GUI wizard to communicate with workflow instances.&lt;br /&gt;
** Participated at NA-MIC Summer 2010 Project Week: [[Summer_project_week_2010_Workflows_SOA]]&lt;br /&gt;
&lt;br /&gt;
=Progress=&lt;br /&gt;
&lt;br /&gt;
* June 10, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
CARMA V.1.0&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code completed and tested&lt;br /&gt;
* Packaging as extension is pending (Subject for Summer 2011 Project week)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Debugging consolidation results issue(SUVs for manual and automated segmentation) &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* June 3, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Deployed on end-user's machine&lt;br /&gt;
* TODO next week: fix SUV results consolidation issue (when MRI segmented ROI got SUV computed for some subjects, only those subjects' SUVs are being added into consolidated report. &amp;quot;Raw&amp;quot; SUV values per subject are generated as expected)  &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 27, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Ready for deployment. New Features: hemispheres EM Segmentation, automated ICC/brainmask extraction using EM Segmenter, fixed controls for MRI conversion and registration&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 20, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General / PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Hemispheres EM Segmentation - adjusted for required label lookup table&lt;br /&gt;
* Use cases added for EM Segmenter General Project: http://www.slicer.org/slicerWiki/index.php/EMSegmenter-Tasks#EMSegmenter_use_cases&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SPECTRE Scull Stripping&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* The new version to be tested on coming week (After PETCT MRI processing migrated to Hemispheres scenario )&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* May 13, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General / PETCT V1.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Hemispheres EM Segmentation - technically works with labal values hardcoded in Slicer EM Segmenter - need to add manual label value edition step&lt;br /&gt;
* PETCT WF Cut for Java GUI (Pending Hemispheres label update completion). Next release will be in QT4.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* May 6, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (QA of EM Segmenter module, work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* April 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Open Discussion for Packaging WF QT Modules as Slicer4 extensions (waiting for SOPs)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review supported projects http://wiki.na-mic.org/Wiki/index.php/File:SlicerWF_EMSegmentProjectsReview.zip &lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (required by Study)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Slicer Modules General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Standardizing Crop Volumes Output (with A. Fedorov's module). Review for required updates of existing product (PET/CT, CARMA)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Open Discussion for Packaging WF QT Modules as Slicer4 extensions (waiting for SOPs)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review supported projects http://wiki.na-mic.org/Wiki/index.php/File:SlicerWF_EMSegmentProjectsReview.zip &lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (required by Study)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Slicer Modules General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Standardizing Crop Volumes Output (with A. Fedorov's module)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 22, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Beta release ready. Demo Location: http://cni29.bwh.harvard.edu/SlicerWFDemo/index.php&lt;br /&gt;
* TODO: Tutorial. Original inputs copy/renaming&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 15, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Adding App server auto-config features&lt;br /&gt;
* Finalizing the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 08, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Second release beta build tested on cosutmer side &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review registration quality (with Dr. Meier). Angiography images' Resampling tuned. &lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 01, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the second release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
XNat Integration&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* (Java) GUI for Project Browsing and DICOM Series Upload. Post-upload DICOM processing tested and debugged&amp;lt;br&amp;gt;&lt;br /&gt;
* Ready for integration with mi2b2 client.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Migrated to Latest Slicer 3.6.3 stable release: only the Input scene had to be updated, the API remained the same&lt;br /&gt;
* Tested EM Segmenter with CMTK4Slicer extension - processing takes to much time on Linux_64bit machine, rolled back to BRAINSFit registration. When used on Mac OS X build, the Slicer could not start (bug report 1126).&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SPECTRE Scull Stripping:&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Testes for various use cases: the module is extremely sensitive to T1 MRI quality (does not work for most MRIs from PET/CT project&lt;br /&gt;
* TODO next week: check for FLAIR images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Slicer4 QT GUI and Cropping activity in progress.&amp;lt;br&amp;gt;&lt;br /&gt;
* Tried direct MRA to MRA registration option: resampling with LMRI registration transforms works better.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Extra VOI labels revised&lt;br /&gt;
* Debugging of SUV results' renormalization step&lt;br /&gt;
* TODO: ICC extraction / whole brain total uptake computing; EM Segmentation for R_WM, L_WM SUV computing and BPH estimation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SCULL STRIPPING/SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Installed and tested CLI option on Linux_64bit platform&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Workflow interruption before BSPline registraton: BPEL Module completed. Slicer4 QT GUI and Cropping activity in prorgess.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Implemented and Tested with end-users proposed changes: denormalization of SUV results, adding more VOI labels, added FLAIR MRI in addition to T1s for VOI drawing&lt;br /&gt;
* Tested manual ICC extraction using PET scans: works satisfactory with island removal and cropping followed by threshold level labeling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4&lt;br /&gt;
* Change proposed: interrupt workflow after affine registration and have user crop the VOI. This is to prevent excessive deformations for BSpline registration and resampling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4. User has option to choose the atlas that fits better for the given subject (NOTE: hardcoding must be rewritten for atlas linking)&lt;br /&gt;
* PETCT test - the problem is that T1s are low resolution and with contrast. Proposed using T1s without contrast&lt;br /&gt;
* PETCT change request: users wants to compute SUV for entire ICC. Had demo how to segment brainmask/ICC using PET scan. The derived brainmask label can be used for SUV computation.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - cmpleted&lt;br /&gt;
* Sample cases run - excessive deformation after BSpline registration hase&lt;br /&gt;
* Next week plan - pull tuning controls to front-end of pipeline API, start working of QT module for CARMA registration&lt;br /&gt;
* May consider other than BRAINSFit registration modules&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Design plan for change request: more VOI labels, add FLAIR in addition to T1 for VOI drawing, T1s segmentation&lt;br /&gt;
* Tested segmentation for sample cases - artifacts from poor quality MRIs lead to exclusion of parts of ICC from segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Completed troubleshooting of EMSegmenter module calling from Java (need TCL libs to be pulled from Slicer environment)&lt;br /&gt;
* Tested EMSegmenter autoruns for HIV and Pediatric MS patiens. Work as expected, subject to improvement of PED MS case segmentation by building better skull/neck/air atalses&lt;br /&gt;
* Suggested usage of two subsets of atalases: with and without neck. The Subject MRIs have to be cropped accordingly or best fit atlas has to be selected&lt;br /&gt;
* Made no-neck cropped atlas collection for default EMSegmenter scenario&lt;br /&gt;
* Tested with PET/CT study MRI cases - see above &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - in progress&lt;br /&gt;
* Next week goal - have back end processing ready&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Longitudinal Study&lt;br /&gt;
* Added MRI registration to the pipeline&lt;br /&gt;
* Troubleshooting of complex XML schema issues on Linux machines (some modules working on MAC do not work on Linux). As a workaround - did not include MRI convert and register part into base BPEL module. Used separate services (transparent for end-user)&lt;br /&gt;
* TODO next week for change request completion: explicit pixel type casting for MRI in BRAINSFit, VOI MRML scene update (currently MRI added on top of schema)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* February 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipeline for Pediatric MRI. Same scenario as for HIV Project, icbm pediatric atlases (Completed, verified)&lt;br /&gt;
* Collected NIH healthy brain development atlases: various age ranges from 4.5 to 18 yo. Converted to Slicer readable format &lt;br /&gt;
* Work on web services for the new automated EM Segmenter module (release Nov 10 - current). Verified task completion both for adult and pediatric images. Discussed tuning parameters for work load balance on workstations.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Started working on MRI registration to the reference CT scans. &lt;br /&gt;
* Design specs for optional White Matter segmentation for SUV computing.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* February 4, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipelines for Pediatric MRI (in progress)&lt;br /&gt;
* Adapting Pediatric T1 atlases for &amp;quot;Human Brain&amp;quot; build-in EM Segmentation wizard (in progress)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 28, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Verifying EM Segmenter module for latest builds and HIV/PED MS Studies (report pending)&lt;br /&gt;
* Work with SPECTRE module developers with pediatric MRI brainmask extraction&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* January 21, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Compiling plan for WF FrontEnd GUI migration to Slicer4/QT Widgets&lt;br /&gt;
* Preparing for annual progress report&lt;br /&gt;
&lt;br /&gt;
* January 14, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI: Integrated into the Slicer4 as Slicelet (or thin Client)&lt;br /&gt;
* Participation at AHM-2011, discussing integration of SPECTRE module and updated approach to EM-Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA&lt;br /&gt;
&lt;br /&gt;
* January 7, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* HIV project workflow delivered. Major additions relate to user convenience: &lt;br /&gt;
- Project-specific parameter settings, importing T1s and brainmasks from FreeSurfer outputs with conversion to NIFTI, resampling brainmask to original scans and automatied subject addition.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Follow up with end user: need to add MRI scans, if available, addition and registration to CT in order to ease VOI drawings.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
 &lt;br /&gt;
* December 31, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Follow-up with user Experience for AGING Study Segmentation (Positive feedback)&lt;br /&gt;
* Target date for HIV project delivery - next week&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Self-training for QT widget development&amp;lt;br&amp;gt;&lt;br /&gt;
* Outlined Workflow Rich Clients migration strategy from Java to QT/Slicer4:&amp;lt;br&amp;gt;&lt;br /&gt;
** Use Java Stubs (similar to SPECTRE integration) or file binding for envocation of workflow pipelines. (See SOAP remark below)&lt;br /&gt;
** Direct Web Servisec calls must be wrapped into REST protocol. The reason: NON-commerchial QT kit does not include SOAP protocol for web servises.&lt;br /&gt;
** The GUI will be implemented as page widget or QT dialog GUI forms called from within Slicer4.&lt;br /&gt;
** Communications between Slicer4 and WF GUI will be set via child-parent and signal-slot relations&lt;br /&gt;
* Worked on a Prototype for Basic EM Segmentation QT widget (70% complete). Will work on integrtion with SLicer4 during the AHM-2010&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
XNAT Integration&lt;br /&gt;
* Debugged XNAT RESTFul API usage for uplaoding DICOM series followed by header data extraction and image snapshots creation&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Added compensation for failed atlas registration (subject for old poor quality pseudo-T1 images): blank probability maps are created in case of failure.&lt;br /&gt;
* Data preparation module for FreeSurfer data import near completion. Expected time for deployment at end-users workstations - first week of January&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Discussed strategy for EM Segmentation pipeline solutions collection (K. Pohl, R. Kikinis)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* RE-using the same core workflow as for 1-channel EM Segmentation of AGING STUDY cases&lt;br /&gt;
* Added data input preparation module: ICC label mask preparation and skull-stripping based on FreeSurfer brainmask output volume.&lt;br /&gt;
* Two-channel EM segmentation pipeline (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE / GENERAL Development &amp;lt;br&amp;gt;&lt;br /&gt;
* Worked on plans for migrating fro rich workflow Java clients to embedded workflow windows inside the Slicer.&amp;lt;br&amp;gt;&lt;br /&gt;
The embedded workflow management clients are to be implemented with QT/PyQT toolkits&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
INTEGRATION WITH XNAT:&amp;lt;br&amp;gt;&lt;br /&gt;
* Automated DICOM series upload with triggering DICOM headers parsing at XNat site (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress. &lt;br /&gt;
- Results upload to XNat (Completed) &amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat based on user's input (Project + Subject + PET or CT session / scan) (Completed)&amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat - perfomance boosting solution for downloads found , web services services are created, relinking for the client side in progress &amp;lt;br&amp;gt;&lt;br /&gt;
- Xnat querying for subjects and automated subject addition into the workflow (In Progress) &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-segmentation module added for auto correction of segmentation results. Particularly - relabeling CSF voxels segmented as Air inside the intracranial cavity. This was requested by end-users after processing images with zero-signals in CSF voxels &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting automated dual-echo DICOM images conversion and split into two NRRD volumes&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT / EM Segmentation pipeline:&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting memory allocation issues for scull-stripping module SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
COPD Project:&amp;lt;br&amp;gt;&lt;br /&gt;
* Benchmark test for accelerated DICOM downloads from XNat (remoote XNat Central server): we can handle at least 6 cases (4 CT scans in each) per hour, which is compatible with current workload quotes on SPL cluster processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* December 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Deployed Version 1. &amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Test project chosen as a closest match to registration scenario: Pediatric MS Cases from MGH - requires periodic image preview for different &lt;br /&gt;
modalities taken from vaious time points. Label maps for VOIs resampling is also required.&lt;br /&gt;
&lt;br /&gt;
* November 26, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user. Version 1 is complete&amp;lt;br&amp;gt;&lt;br /&gt;
* Started working on integration with XNat&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on input data organizing modules&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 19, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user (70% done)&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Universal Registration Workflow for Longitudinal Studies - design specs in progress&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 12, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Minor tuning to EM Segmentation template as of users' feedback&lt;br /&gt;
* Users started using the workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed input data conversion from Genesis to Slicer native or NIFTI format. Our help may be needed in input data organizing.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Tuned application according to co-laborators (PNL) needs&amp;lt;br&amp;gt;&lt;br /&gt;
* The webservices and BPEL workflow application are tested ready to accept computation requests from PNL case tracking system &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Discussed Universal Registration Workflow for Longitudinal Studies&lt;br /&gt;
* Started the thread about possible cooperation with Children hospital's image processing pipelines and integration with Xnat &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 5, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Webservices and workflow pilot project created and deployed on Psychiatry Neuroimaging Laboratory subnet &amp;lt;br&amp;gt;&lt;br /&gt;
* The V.1.0 deployment is scheduled for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 29, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Most of functionality is completed. Some volume statistics post processing is pending&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL EM SEGMENTATION Pipeline: &amp;lt;br&amp;gt;&lt;br /&gt;
* The SPECTRE scull stripping module. Started integration into EMS workflow. Made some test runs from Slicer GUI&amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Identified as a candidate for Workflow Application&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 22, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* All back-end functionality are implemented&amp;lt;br&amp;gt;&lt;br /&gt;
* EM Segmentation scene usability is confirmed by end-user&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for next week: add Label Statistics computation for CSF/Brain/ICC &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 15, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* The latest (October) builds of Slicer 3.6.2 produced acceptable results. This was verified by the target users. The EM Segmentation will be performed on Slicer 3.6.2 or later&amp;lt;br&amp;gt;&lt;br /&gt;
* The new Web services had been created and added to the pipeline as optional processing steps: Biasfield correction (implement novel N2ITKBiasFieldCorrection module) and Volume's scalar datatype casting (as workaround for Biasfield correction module not preserving image scalar datatype - the bug is filed) &amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed the Front-End GUI design with target users. The design pattern is taken from the PETCT project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 8, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-deployment support. Tuned CT registration as of user's feedback.&lt;br /&gt;
* Adapting to the Single Slicer build: Slicer 3.6.2. Found label duplicates in the label lookup table - will ask user if it's tolerable. Waiting for the Slicer 3.6.2 build that contains all required modules. Rolling back label tag appending code for SUVs - the latest Slicer build appends the tags.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Resumed development. The priorities are set for usage of Slicer 3.6.2 - subject for EM Segmentation scene tuning. Continued coding for Scene creation for Slicer 2.8 - as a backup option for ongoing research project.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 1, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized V1.0 release based on end-user feedback: updates relate mostly to error proofing and SUV values representation&lt;br /&gt;
* Post-deployment support. Users pre-processed first set of patients &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* September 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* System deployed and tested at End Users' site.&amp;lt;br&amp;gt;Users are trained to perform all tasks required by the workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
* Got positive feedback with suggestions on Slicer Scenes' layouts improvement and PET scans' SUV (standard uptake values) results display&lt;br /&gt;
* Two distribution packages are assembled: Lunix and MAC OS versions. The difference in two packages is in specific Slicer3.6/3.7 builds - subject to Slicer Linux builds debugging.&amp;lt;br&amp;gt; As a workaround for Linux deployment - multiple Slicer builds are used to perform various tasks (registration, opening editing scenes in Slicer, SUV computing)&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for coming week - finalize V1.0 release based on end-user feedback&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Embedded SUV computations into the workflow (as system calls - will be translated into web service later)&amp;lt;br&amp;gt;&lt;br /&gt;
* Pre-release demo for end users.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Create and debug EM Segmenter scenes template for Slicer 3.6 and 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* September 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation - workflow pipeline and deployment verified&amp;lt;br&amp;gt;&lt;br /&gt;
* Tested EM Segmentation scenes within Slicer 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
* Started migration of EM Segmentation to Slicer 3.6. Discovered issues had been reported to EM Segmenter module designers &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* August 29 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation completed. Preprocessing Pipleine completed 80% (subject for input registration parameters tuning) &amp;lt;br&amp;gt;&lt;br /&gt;
* Most webservices (for registration and resampling steps) had been taken and re-used from PET/CT ROI/Longitudinal Study - showing the advantage of service-oriented software design and deployment.&lt;br /&gt;
* Continued on distribution and deployment of the service/workflow applications: on PET/CT and AGING STUDY projects.&lt;br /&gt;
&lt;br /&gt;
PEDIATRIC Multiple Sclerosis Cohort. Support of multi-center distributed processing project&amp;lt;br&amp;gt;&lt;br /&gt;
* Introduced Slicer 3.6 for the MS Lesion Assessment step performed at Mayo Clinic. Images are being transferred from image repository at BWH and automatically opened and arranged within Slicer GUI for reading.  This was replacement of Client GUI using MIPAV that stopped working on new computers at Mayo Clinic.&lt;br /&gt;
The images are being loaded via generated MRML Scenes same way as in PET/CT and AGING STUDY projects &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* August 22 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Preprocessing pipeline merge with SUV computations &amp;lt;br&amp;gt;&lt;br /&gt;
- QA for SUVs computation was performed by Wendy Plesniak for images with known uptake values. &amp;lt;br&amp;gt;&lt;br /&gt;
- Discovered that image cropping step (not related to automated registration pipeline and SUVs computing) smoothes the images by doing interpolation when used with default settings. Got suggestions from Steve Piper using Nearest-Neighbor interpolation (&amp;quot;no interpolation&amp;quot;) for a time being&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
- This is the new project candidate. Requested for the images with failed manual segmentation and/or segmentation with FreeSurfer. The EM Segmentation run showed most acceptable results on one of the problem images back in February &amp;lt;br&amp;gt;&lt;br /&gt;
- The workflow will be developed and deployed similar to PET/CT ROI Longitudinal study approach - all preprocessing steps will be done with Slicer modules, all runs will be performed on local end-user machines.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
 &lt;br /&gt;
&lt;br /&gt;
* August 15 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- First 5 cases with 3-4 time points preprocessed for SUVs computation&lt;br /&gt;
&lt;br /&gt;
* August 8 2010&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Testing of installation and operation at users' site (Performed by Wendy Plesniak)&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* July 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Delivered beta version of registration pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
- Prepared installation and user manuals &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* June 11, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Registration modules completed &amp;lt;br&amp;gt;&lt;br /&gt;
- Irregular cases registration problem solved (when whole body and brain only scans are mixed for a timepoint)&amp;lt;br&amp;gt;&lt;br /&gt;
- Live demo of case setup and registration workflow for end users. Real case with 4 timepoints used&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Coming week plans&amp;lt;br&amp;gt;&lt;br /&gt;
- Adjust workflow based on end users' feedback&amp;lt;br&amp;gt;&lt;br /&gt;
- Integration with SUVs computing for PET scans&amp;lt;br&amp;gt;&lt;br /&gt;
- GUI for workflows dispatching and data organizing&amp;lt;br&amp;gt;&lt;br /&gt;
- (TBD) Integration with 4D time series analysis Slicer module&amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
* May 28, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- Migration to the latest Slicer 3.6 release candidate &amp;lt;br&amp;gt;&lt;br /&gt;
- Added webservice for new registration module: BRAINSFit &amp;lt;br&amp;gt;&lt;br /&gt;
- Test runs for new patients with 4 timepoints' scans &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Plans for next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI &amp;lt;br&amp;gt;&lt;br /&gt;
- processing workflow demo for end user &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 21, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Pilot version of portable web services and automated workflow tested: &amp;lt;br&amp;gt;&lt;br /&gt;
Linux: workflow and visual review passed&amp;lt;br&amp;gt;&lt;br /&gt;
Stress test for 25 timepoints passed &amp;lt;br&amp;gt;&lt;br /&gt;
MAC OS: workflow passed, visual review failing when PET/CT images are loaded into GUI simultaneously (bug report submitted)&amp;lt;br&amp;gt;&lt;br /&gt;
Windows: need to adapt command line modules and workflow management system to sygwin environment&amp;lt;br&amp;gt;&lt;br /&gt;
Plans for next week: integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI&lt;br /&gt;
&lt;br /&gt;
* May 7, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Selected registration and resampling modules with more precise and stable outputs. &amp;lt;br&amp;gt;&lt;br /&gt;
Started building portable web services and automated workflow &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 30, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- manual walk through the processing steps: ROI cropping, registration/resampling, PET pharmaceutical DICOM data retention. &amp;lt;br&amp;gt;&lt;br /&gt;
- testing workflow and web services packages distribution to end-users' machines&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* April 23, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : testing various registration and re-sampling algorithms (work in progress)&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation: as of collaborators' request, run existing EM Segmentation workflow for older low resolution pseudo-T1 images. The EM Segmentation works for those images with manual sampling. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 16, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
  Social Cognition Study: started Cortical Thickness Measurement module build (bases on NA-MIC ARCTIC pipeline) &amp;lt;br&amp;gt;&lt;br /&gt;
  PET/CT ROI/Longitudinal Study Registration : Design specs, PET-to-CT images registration tests on training data. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 9, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. GUI update based on end-user experience.&amp;lt;br&amp;gt;&lt;br /&gt;
User request: automated label maps' volumes calculation (Currently possible from Slicer3 GUI)&amp;lt;br&amp;gt; &lt;br /&gt;
PET/CT ROI Project. Initial design specs discussion with end-users and co-developers&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure&lt;br /&gt;
Verification of segmentation workflow GUI: from registering new case to reviewing results&amp;lt;br&amp;gt;&lt;br /&gt;
Cross study test of segmentation workflow: MGH/MS Center data - success,  HIV Project data - some EM Segmentation scene tuning is needed &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*&lt;br /&gt;
* April 2, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. Segmentation workflow completed&amp;lt;br&amp;gt;&lt;br /&gt;
* Coming Week plans:&amp;lt;br&amp;gt;&lt;br /&gt;
- Document Segmentation Workflow. Follow up with end users &amp;lt;br&amp;gt;&lt;br /&gt;
- Start with Cortical Thickness and ROI-in-longitudinal studies workflows&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* March 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All essential processing and workflow interaction clients are ready.&amp;lt;br&amp;gt;&lt;br /&gt;
- Completed segmentation for 10 out of 50 patients. The remaining cases will be finalized upon manual lesion segmentation and QC verification of WM/GM/CSF and Deep GM segmentation's. &amp;lt;br&amp;gt;&lt;br /&gt;
- TODO next week: refine QC GUI and data tracking / progress monitoring schema. &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&amp;lt;br&amp;gt;&lt;br /&gt;
- New Slicer3 web services added: re-slicing with reference image volume, casting image scalar type &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
* March 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Segmentation maps Merging Services for GM/WM/CSF (Slicer EM Segemnter), Lesion (Slicer, Manual), and Deep GM (FreeSurfer)  &amp;lt;br&amp;gt;&lt;br /&gt;
- Deep GM segmentation pipeline adopted as optional service for Social Cognition Study (22 out of 50 cases processed) &amp;lt;br&amp;gt;&lt;br /&gt;
- (In progress) GUI client for Launching Segmentation results merging with optional Deep GM segmentation with FreeSurfer &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- Complete GUI Client for Segmentation result merging &amp;lt;br&amp;gt;&lt;br /&gt;
- Progress Monitoring services for entire Study processing: EM Segmenter Preprocessing, EM Segmentation, Lesion Segmentation (including human activities assignments), Deep GM segmentation, and results consolidation. &amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* March 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All 50 cases went through &amp;quot;basic&amp;quot; One-channel EM segmentation (GM/WM/CSF) &amp;lt;br&amp;gt;&lt;br /&gt;
- Basic pipeline start-up command line client created: user has two options - request brainmask extraction or provide with previously extracted brainmask for a given subject &amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison of GM/WN/CSF performed for Slicer EM Segmenter and FreeSurfer recon-all (used with default settings). &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmenter provides more accurate output &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmentation pipeline runs faster (40 minutes vs 12 hrs when no brainmask extraction requested) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO:&amp;lt;br&amp;gt;&lt;br /&gt;
- merging modules for automatic 1-channel EM segmentation and manual lesion segmentation &amp;lt;br&amp;gt;&lt;br /&gt;
- Emerge Cortical Thickness pipeline project: use NAC ARCTIC processing steps and modules &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Selected stable EM Segmentation scenario: White Matter, Gray Matter, and Cerebrospinal Fluid &amp;lt;br&amp;gt;&lt;br /&gt;
- First 16 cases are segmented for selected scenario. Nine more cases are preprocessed for EM Segmentation.&amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison to segmentation with FreeSurfer showed better accuracy for Slicer2 EMSegmenter &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure &amp;lt;br&amp;gt;&lt;br /&gt;
- Three prerpcocessed cases failed during volume ICC masking with in-house build utility. Evaluated switching to Slicer3 Mask and island removing modules.&amp;lt;br&amp;gt;&lt;br /&gt;
- Initial design specs discussion for cortical thickness measurement pipeline. ARCTIC pipeline selected. ARCTIC preprocessing steps signifficantly overlap with EM Segmentation preprocessing workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
  &lt;br /&gt;
* February 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: &amp;lt;br&amp;gt;&lt;br /&gt;
A) parameters tuning for EM Segmenter itself (work with EM Segmenter developer), template scenes creation &amp;lt;br&amp;gt;&lt;br /&gt;
B) update preprocessing pipeline - deep gray matter atlases included &amp;lt;br&amp;gt;&lt;br /&gt;
C) test and debug preprocesing pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
D) identified missing modules: atlas autocalibration for EM Segmentation scene, Island removal for ICC mask&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- Review currently deployed modules. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: reviewed firts seven subjects' outputs, added volume orientation module into pipeline (prevents ICBM atlas linear registration failures)&amp;lt;br&amp;gt;&lt;br /&gt;
- Fused ICC(brainmask) extraction module with EM Segmenter preprocessing. Three scenarious implemented: start with pre-extracted ICC mask (longitudinal studies case), run with ICC ectration, run with ICC extraction AND ICC correction before ICBM atlas preporcessing. &amp;lt;br&amp;gt;&lt;br /&gt;
- Completion of Human activities GUI (QC, ICC Correction) planned for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: Volume Orientation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: automated preprocessing pipeline for Slicer2 EM Segmenter test version deployed. Seven cases pre-processed.&lt;br /&gt;
- PET Quantitative measurements: Preliminary design specs discussion.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: BSplineRegistration (for non-linear registration), ResampleVolume2 (for atlases resampling based on image atlase templates registration). Local and Network runs are implemented, Cluster/GridWizard implementation pending.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Slicer EM Segmenter module: preprocessing design for Slicer2 EM Segmenter&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Adapting for Slicer2 EM Segmenter (mostly from pipelines and services for previous projects)&lt;br /&gt;
  -- Integration with FreeSurfer modules for bisafield correction, brainmask extraction, and linear registration of ICBM atlases&lt;br /&gt;
  -- Preprocessing updates for non-linear registration of ICBM atlases with Slicer2 (image re-orientation service designed)&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 29, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- EM Segmentaton pipeline: preprocessing results are being transferred to XNat (anonymized data, Central XNat) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Slicer EM Segmenter module: discussed agenda and scheduled a work meeting for Social Cognition Study image segmentation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Testing stage, 95% completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- SPL XNat server: verified data exchange via RESTfull web services.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 22, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Follow up with White Matter Lesion Segmenter and Scull Stripping Modules developers: Work in Progress&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Work in Progress, 60%+ completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Discussed SPINE image repository migration to XNat&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 15, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. &lt;br /&gt;
- Social Cognition Study: &lt;br /&gt;
Work-in-progress on intermediate (reconstruction) and results (resources) data storage at XNat.&lt;br /&gt;
&amp;lt;br&amp;gt;Reviewing and preparation more cases for EM Segmentor (Slicer 3.5) tuning.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* NA-MIC Project Week&lt;br /&gt;
Selecting candidate Slicer modules for other than Lesion EM Segmentation topics of Social Cognition study: Withe Matter Lesion Segmenter (UNC), Scull Stripping utility from UIOWA.&lt;br /&gt;
Reviewing issues of currently used Scull Stripping Slicer Extension and Slicer 3.5 EM Segmenter.&lt;br /&gt;
&amp;lt;br&amp;gt;XNat Data organizing training&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 1, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Preparation of Demo for NA-MIC work week: &lt;br /&gt;
- COPD Study. Added Remote pipepline start interface (represents real world scenario where Xnat repository, Processing modules and User are at different sites)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
- EM Segmentation. Added human activities steps to the workflow: ICC (brainmask) correction and EM Segmantation scena load per se.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 25, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Pilot workflow pipeline for EM Segmentation (all steps except user-activity step: ICC correction assignment and tracking)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 18, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Build and tested web services for EM Segmentation image preprocessing: DICOM-to-NRRD conversion, registration, skull stripping, image masking.&lt;br /&gt;
Started building workflow pipeline (subject to finish first version next week)&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Started Collecting Library of Slicer Build number vs. functional modules and extensions.&lt;br /&gt;
Plan for NAMIC project week: scheduled meetings for XNat data customization, Skull-stripping modules tuning, identified Social Cognition study cases that fail EM Segmentation processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 11, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Updating and verification of EM Segmentation Scenario&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Projects:ARRA:SlicerWF:UseCaseScenarios#Usecase_MS_lesion_Assessment&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Familiarizing with Slicer3.4/5 Modules required for implementation of EM Segmentation Scenario. Participation in debugging and/or usage tuning of Dicom Conversion, Registration, Skull Stripping, Masking, and Image Casting modules. &lt;br /&gt;
&lt;br /&gt;
* December 4, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Slicer3.4's EM Segmentation and Visual QC as part of image processing pipeline for Social Cognition Study for MS Patients.&lt;br /&gt;
Project emerged. EM Segmentation template creation debugged.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
Emphysema Measurements (COPD Study) - workflow stability and scalability test.&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 27, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Emphysema Measurements (COPD Study).&lt;br /&gt;
Added compensation for long running calculations and time-outs to the main computing pipeline.&lt;br /&gt;
Visual QC (work in progress)&lt;br /&gt;
** Infrastructure&lt;br /&gt;
XNat data structure customization, metadata storage, results consolidation: new feature request list creation (work in progress)&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 13, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
*** Pilot system for whole processing cycle for Emphysema Measurements (COPD Study) including the following:&lt;br /&gt;
Web query for CT session file list download&lt;br /&gt;
Pilot user interface for submitting the file list and starting processing pipeline&lt;br /&gt;
Notification about processing steps and failures&lt;br /&gt;
Upload results to XNat repository (at this stage results are uploaded into same folder where original scans are(*))&lt;br /&gt;
*** Immediate Plans&lt;br /&gt;
Complete Visual QC module&lt;br /&gt;
Design and implement meta-data transfer to XNat (including processing details and MRML files for loading images into the 3D Slicer)&lt;br /&gt;
&lt;br /&gt;
(*)Customization of results storage&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 6, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Tuned and debugged multiple subjects processing for: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat.&lt;br /&gt;
***Started working on quality control embedding into the above scenario. Plan to complete and video-record demo next week.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***Published general Product Integration scenario flow chart to collaborators' community. Discussion is open and in progress&lt;br /&gt;
&lt;br /&gt;
* October 30, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Piloted and tested the sequence: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat(1).&lt;br /&gt;
***Performance test of overall cycle: data transfer from remote serve is a bottleneck as expected&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data browsing features reviewed.&lt;br /&gt;
(1) Not automated yet&lt;br /&gt;
* October 23, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Defined COPD processing scenario with interoperability between Xnat, 3D Slicer Command Modules, Workflow, and Gridwizard Enterprise.&lt;br /&gt;
***Pilot version of Emphysema Measurements workflow pipeline deployed.&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data transfer features reviewed. Use account at XNat Central during learning curve.&lt;br /&gt;
***Feasibility test of 3D Slicer fiducials module for ROI highlights during QC and manual image processing activities. &lt;br /&gt;
* October 16, 2009&lt;br /&gt;
**Lung CT Scans Processing. Pilot project emerged. GenerateEmphysemaMeasurements module deployed as a webservice that submits jobs to computational cluster.&lt;br /&gt;
**EM Segmentation. Familiarized with GUI steps. Started working on automation steps outlining&lt;br /&gt;
**3D Slicer and XNat interaction. Got an overview from Wendy Plesniak.&lt;br /&gt;
* October 1 - 7, 2009&lt;br /&gt;
**Selected two first priority Projects: EM Segmentation of brain MRI images; Lung CT Scans Processing (COPD Study)&lt;br /&gt;
**Got initial outline of user requirements and design specs&lt;/div&gt;</summary>
		<author><name>Azaitsev</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=Summer_project_week_2011_Workflows_SOA&amp;diff=68182</id>
		<title>Summer project week 2011 Workflows SOA</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=Summer_project_week_2011_Workflows_SOA&amp;diff=68182"/>
		<updated>2011-06-15T05:56:34Z</updated>

		<summary type="html">&lt;p&gt;Azaitsev: /* Delivery Mechanism */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
Image:PW-MIT2011.png|[[2011_Summer_Project_Week#Projects|Projects List]]&lt;br /&gt;
Image:notfound.png|Interesting picture to be added... &lt;br /&gt;
&amp;lt;/gallery&amp;gt;&lt;br /&gt;
&lt;br /&gt;
'''Workflows and Service Oriented Architecture Modules for Slicer4 as Extensions'''&lt;br /&gt;
&lt;br /&gt;
==Key Investigators==&lt;br /&gt;
* Brigham and Womens Hospital, Harvard Medical School: Alexander Zaitsev, Wendy Plesniak, Ron Kikini&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;margin: 20px;&amp;quot;&amp;gt;&lt;br /&gt;
&amp;lt;div style=&amp;quot;width: 27%; float: left; padding-right: 3%;&amp;quot;&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;h3&amp;gt;Objective&amp;lt;/h3&amp;gt;&lt;br /&gt;
&lt;br /&gt;
#:Thin clients for Slicer4 to support standardized workflows&lt;br /&gt;
#:&lt;br /&gt;
#:Automation of image processing steps, data management&lt;br /&gt;
#:&lt;br /&gt;
#:Combination of automated methods with human activities&lt;br /&gt;
#:Case Studies: Left Atrial Ablation follow-up, Brain PET/CT/MRI scans processing for cancer treatmen follow-up, brain atrophy estimation  &lt;br /&gt;
#:Major methods/algorithms used by workflows: Registration (BRAINSFit, BRAINSResample), Biasfield correction&lt;br /&gt;
&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;width: 27%; float: left; padding-right: 3%;&amp;quot;&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;h3&amp;gt;Approach, Plan&amp;lt;/h3&amp;gt;&lt;br /&gt;
#:Trying to build existing thin clients (Slicelets)  &lt;br /&gt;
#:as Slicer4 Extensions.&lt;br /&gt;
#:&lt;br /&gt;
#:Incorporate MS Lesion EM Segmentation&lt;br /&gt;
#:Scenario into the workflows  &lt;br /&gt;
&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;width: 40%; float: left;&amp;quot;&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;h3&amp;gt;Progress&amp;lt;/h3&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;!-- Fill this out before Friday's summary presentations - list what you did and how well it worked. --&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;width: 97%; float: left;&amp;quot;&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA Winter_project_week_2011_Workflows_SOA]] Winter 2001 Project Week Page&lt;br /&gt;
&lt;br /&gt;
==Delivery Mechanism==&lt;br /&gt;
&lt;br /&gt;
&amp;lt;!-- List here how you plan to deliver your results to user communities --&amp;gt;&lt;br /&gt;
&lt;br /&gt;
This work will be delivered to the NAMIC Kit as a &lt;br /&gt;
&lt;br /&gt;
##Built-in: &lt;br /&gt;
##Extension -- commandline:  &lt;br /&gt;
##Extension -- loadable:&lt;/div&gt;</summary>
		<author><name>Azaitsev</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=Summer_project_week_2011_Workflows_SOA&amp;diff=68181</id>
		<title>Summer project week 2011 Workflows SOA</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=Summer_project_week_2011_Workflows_SOA&amp;diff=68181"/>
		<updated>2011-06-15T05:56:05Z</updated>

		<summary type="html">&lt;p&gt;Azaitsev: /* Key Investigators */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
Image:PW-MIT2011.png|[[2011_Summer_Project_Week#Projects|Projects List]]&lt;br /&gt;
Image:notfound.png|Interesting picture to be added... &lt;br /&gt;
&amp;lt;/gallery&amp;gt;&lt;br /&gt;
&lt;br /&gt;
'''Workflows and Service Oriented Architecture Modules for Slicer4 as Extensions'''&lt;br /&gt;
&lt;br /&gt;
==Key Investigators==&lt;br /&gt;
* Brigham and Womens Hospital, Harvard Medical School: Alexander Zaitsev, Wendy Plesniak, Ron Kikini&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;margin: 20px;&amp;quot;&amp;gt;&lt;br /&gt;
&amp;lt;div style=&amp;quot;width: 27%; float: left; padding-right: 3%;&amp;quot;&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;h3&amp;gt;Objective&amp;lt;/h3&amp;gt;&lt;br /&gt;
&lt;br /&gt;
#:Thin clients for Slicer4 to support standardized workflows&lt;br /&gt;
#:&lt;br /&gt;
#:Automation of image processing steps, data management&lt;br /&gt;
#:&lt;br /&gt;
#:Combination of automated methods with human activities&lt;br /&gt;
#:Case Studies: Left Atrial Ablation follow-up, Brain PET/CT/MRI scans processing for cancer treatmen follow-up, brain atrophy estimation  &lt;br /&gt;
#:Major methods/algorithms used by workflows: Registration (BRAINSFit, BRAINSResample), Biasfield correction&lt;br /&gt;
&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;width: 27%; float: left; padding-right: 3%;&amp;quot;&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;h3&amp;gt;Approach, Plan&amp;lt;/h3&amp;gt;&lt;br /&gt;
#:Trying to build existing thin clients (Slicelets)  &lt;br /&gt;
#:as Slicer4 Extensions.&lt;br /&gt;
#:&lt;br /&gt;
#:Incorporate MS Lesion EM Segmentation&lt;br /&gt;
#:Scenario into the workflows  &lt;br /&gt;
&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;width: 40%; float: left;&amp;quot;&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;h3&amp;gt;Progress&amp;lt;/h3&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;!-- Fill this out before Friday's summary presentations - list what you did and how well it worked. --&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;width: 97%; float: left;&amp;quot;&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA Winter_project_week_2011_Workflows_SOA]] Winter 2001 Project Week Page&lt;br /&gt;
&lt;br /&gt;
==Delivery Mechanism==&lt;br /&gt;
&lt;br /&gt;
&amp;lt;!-- List here how you plan to deliver your results to user communities --&amp;gt;&lt;br /&gt;
&lt;br /&gt;
This work will be delivered to the NAMIC Kit as a &lt;br /&gt;
&lt;br /&gt;
#NITRIC distribution&lt;br /&gt;
#Slicer Module&lt;br /&gt;
##Built-in: &lt;br /&gt;
##Extension -- commandline:  &lt;br /&gt;
##Extension -- loadable:&lt;/div&gt;</summary>
		<author><name>Azaitsev</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=Summer_project_week_2011_Workflows_SOA&amp;diff=68180</id>
		<title>Summer project week 2011 Workflows SOA</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=Summer_project_week_2011_Workflows_SOA&amp;diff=68180"/>
		<updated>2011-06-15T05:53:50Z</updated>

		<summary type="html">&lt;p&gt;Azaitsev: /* References */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
Image:PW-MIT2011.png|[[2011_Summer_Project_Week#Projects|Projects List]]&lt;br /&gt;
Image:notfound.png|Interesting picture to be added... &lt;br /&gt;
&amp;lt;/gallery&amp;gt;&lt;br /&gt;
&lt;br /&gt;
'''Workflows and Service Oriented Architecture Modules for Slicer4 as Extensions'''&lt;br /&gt;
&lt;br /&gt;
==Key Investigators==&lt;br /&gt;
* Brigham and Womens Hospital, Harvard Medical School: Alexander Zaitsev, Wendy Plesniak, Ron Kikini&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;margin: 20px;&amp;quot;&amp;gt;&lt;br /&gt;
&amp;lt;div style=&amp;quot;width: 27%; float: left; padding-right: 3%;&amp;quot;&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;h3&amp;gt;Objective&amp;lt;/h3&amp;gt;&lt;br /&gt;
&lt;br /&gt;
#:Thin clients for Slicer4 to support standardized workflows&lt;br /&gt;
#:Automation of image processing steps, data management&lt;br /&gt;
#:Combination of automated methods with human activities&lt;br /&gt;
#:Case Studies: Left Atrial Ablation follow-up, Brain PET/CT/MRI scans processing for cancer treatmen follow-up, brain atrophy estimation  &lt;br /&gt;
#:Major methods/algorithms used by workflows: Registration (BRAINSFit, BRAINSResample), Biasfield correction&lt;br /&gt;
&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;width: 27%; float: left; padding-right: 3%;&amp;quot;&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;h3&amp;gt;Approach, Plan&amp;lt;/h3&amp;gt;&lt;br /&gt;
#:Trying to build existing thin clients (Slicelets)  &lt;br /&gt;
#:as Slicer4 Extensions.&lt;br /&gt;
#:Incorporate MS Lesion EM Segmentation&lt;br /&gt;
#:Scenario into the workflows  &lt;br /&gt;
&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;width: 40%; float: left;&amp;quot;&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;h3&amp;gt;Progress&amp;lt;/h3&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;!-- Fill this out before Friday's summary presentations - list what you did and how well it worked. --&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;width: 97%; float: left;&amp;quot;&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA Winter_project_week_2011_Workflows_SOA]] Winter 2001 Project Week Page&lt;br /&gt;
&lt;br /&gt;
==Delivery Mechanism==&lt;br /&gt;
&lt;br /&gt;
&amp;lt;!-- List here how you plan to deliver your results to user communities --&amp;gt;&lt;br /&gt;
&lt;br /&gt;
This work will be delivered to the NAMIC Kit as a &lt;br /&gt;
&lt;br /&gt;
#NITRIC distribution&lt;br /&gt;
#Slicer Module&lt;br /&gt;
##Built-in: &lt;br /&gt;
##Extension -- commandline:  &lt;br /&gt;
##Extension -- loadable:&lt;/div&gt;</summary>
		<author><name>Azaitsev</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=Summer_project_week_2011_Workflows_SOA&amp;diff=68179</id>
		<title>Summer project week 2011 Workflows SOA</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=Summer_project_week_2011_Workflows_SOA&amp;diff=68179"/>
		<updated>2011-06-15T05:50:49Z</updated>

		<summary type="html">&lt;p&gt;Azaitsev: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
Image:PW-MIT2011.png|[[2011_Summer_Project_Week#Projects|Projects List]]&lt;br /&gt;
Image:notfound.png|Interesting picture to be added... &lt;br /&gt;
&amp;lt;/gallery&amp;gt;&lt;br /&gt;
&lt;br /&gt;
'''Workflows and Service Oriented Architecture Modules for Slicer4 as Extensions'''&lt;br /&gt;
&lt;br /&gt;
==Key Investigators==&lt;br /&gt;
* Brigham and Womens Hospital, Harvard Medical School: Alexander Zaitsev, Wendy Plesniak, Ron Kikini&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;margin: 20px;&amp;quot;&amp;gt;&lt;br /&gt;
&amp;lt;div style=&amp;quot;width: 27%; float: left; padding-right: 3%;&amp;quot;&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;h3&amp;gt;Objective&amp;lt;/h3&amp;gt;&lt;br /&gt;
&lt;br /&gt;
#:Thin clients for Slicer4 to support standardized workflows&lt;br /&gt;
#:Automation of image processing steps, data management&lt;br /&gt;
#:Combination of automated methods with human activities&lt;br /&gt;
#:Case Studies: Left Atrial Ablation follow-up, Brain PET/CT/MRI scans processing for cancer treatmen follow-up, brain atrophy estimation  &lt;br /&gt;
#:Major methods/algorithms used by workflows: Registration (BRAINSFit, BRAINSResample), Biasfield correction&lt;br /&gt;
&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;width: 27%; float: left; padding-right: 3%;&amp;quot;&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;h3&amp;gt;Approach, Plan&amp;lt;/h3&amp;gt;&lt;br /&gt;
#:Trying to build existing thin clients (Slicelets)  &lt;br /&gt;
#:as Slicer4 Extensions.&lt;br /&gt;
#:Incorporate MS Lesion EM Segmentation&lt;br /&gt;
#:Scenario into the workflows  &lt;br /&gt;
&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;width: 40%; float: left;&amp;quot;&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;h3&amp;gt;Progress&amp;lt;/h3&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;!-- Fill this out before Friday's summary presentations - list what you did and how well it worked. --&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;width: 97%; float: left;&amp;quot;&amp;gt;&lt;br /&gt;
&lt;br /&gt;
==References==&lt;br /&gt;
D’Avila A, Scanavacca M, Sosa E, Riskin JN, Reddy VY. Pericardial anatomy for the Interventional Electrophysiologist. J Cardiovasc Electrophysiol 2003;14:422-430&lt;br /&gt;
&lt;br /&gt;
==Delivery Mechanism==&lt;br /&gt;
&lt;br /&gt;
&amp;lt;!-- List here how you plan to deliver your results to user communities --&amp;gt;&lt;br /&gt;
&lt;br /&gt;
This work will be delivered to the NAMIC Kit as a &lt;br /&gt;
&lt;br /&gt;
#NITRIC distribution&lt;br /&gt;
#Slicer Module&lt;br /&gt;
##Built-in: &lt;br /&gt;
##Extension -- commandline:  &lt;br /&gt;
##Extension -- loadable:&lt;/div&gt;</summary>
		<author><name>Azaitsev</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=Summer_project_week_2011_Workflows_SOA&amp;diff=68178</id>
		<title>Summer project week 2011 Workflows SOA</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=Summer_project_week_2011_Workflows_SOA&amp;diff=68178"/>
		<updated>2011-06-15T05:40:58Z</updated>

		<summary type="html">&lt;p&gt;Azaitsev: /* Key Investigators */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
Image:PW-MIT2011.png|[[2011_Summer_Project_Week#Projects|Projects List]]&lt;br /&gt;
Image:notfound.png|Interesting picture to be added... &lt;br /&gt;
&amp;lt;/gallery&amp;gt;&lt;br /&gt;
&lt;br /&gt;
'''Full Title of Project'''&lt;br /&gt;
&lt;br /&gt;
==Key Investigators==&lt;br /&gt;
* Brigham and Womens Hospital, Harvard Medical School: Alexander Zaitsev, Wendy Plesniak, Ron Kikini&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;margin: 20px;&amp;quot;&amp;gt;&lt;br /&gt;
&amp;lt;div style=&amp;quot;width: 27%; float: left; padding-right: 3%;&amp;quot;&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;h3&amp;gt;Objective&amp;lt;/h3&amp;gt;&lt;br /&gt;
&lt;br /&gt;
#:Segmentaion and 3d &lt;br /&gt;
#:reconstruction of pericardial sac&lt;br /&gt;
#: (a thin tissue layer that covers the heart)&lt;br /&gt;
&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;width: 27%; float: left; padding-right: 3%;&amp;quot;&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;h3&amp;gt;Approach, Plan&amp;lt;/h3&amp;gt;&lt;br /&gt;
#:Trying 3dslicer modules &lt;br /&gt;
#:for segmentation &lt;br /&gt;
#:and 3d reconstruction   &lt;br /&gt;
&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;width: 40%; float: left;&amp;quot;&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;h3&amp;gt;Progress&amp;lt;/h3&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;!-- Fill this out before Friday's summary presentations - list what you did and how well it worked. --&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;width: 97%; float: left;&amp;quot;&amp;gt;&lt;br /&gt;
&lt;br /&gt;
==References==&lt;br /&gt;
D’Avila A, Scanavacca M, Sosa E, Riskin JN, Reddy VY. Pericardial anatomy for the Interventional Electrophysiologist. J Cardiovasc Electrophysiol 2003;14:422-430&lt;br /&gt;
&lt;br /&gt;
==Delivery Mechanism==&lt;br /&gt;
&lt;br /&gt;
&amp;lt;!-- List here how you plan to deliver your results to user communities --&amp;gt;&lt;br /&gt;
&lt;br /&gt;
This work will be delivered to the NAMIC Kit as a &lt;br /&gt;
&lt;br /&gt;
#NITRIC distribution&lt;br /&gt;
#Slicer Module&lt;br /&gt;
##Built-in: &lt;br /&gt;
##Extension -- commandline:  &lt;br /&gt;
##Extension -- loadable:&lt;/div&gt;</summary>
		<author><name>Azaitsev</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=Summer_project_week_2011_Workflows_SOA&amp;diff=68177</id>
		<title>Summer project week 2011 Workflows SOA</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=Summer_project_week_2011_Workflows_SOA&amp;diff=68177"/>
		<updated>2011-06-15T05:39:49Z</updated>

		<summary type="html">&lt;p&gt;Azaitsev: Created page with '__NOTOC__ &amp;lt;gallery&amp;gt; Image:PW-MIT2011.png|Projects List Image:notfound.png|Interesting picture to be added...  &amp;lt;/gallery&amp;gt;  '''Full Title of P…'&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
Image:PW-MIT2011.png|[[2011_Summer_Project_Week#Projects|Projects List]]&lt;br /&gt;
Image:notfound.png|Interesting picture to be added... &lt;br /&gt;
&amp;lt;/gallery&amp;gt;&lt;br /&gt;
&lt;br /&gt;
'''Full Title of Project'''&lt;br /&gt;
&lt;br /&gt;
==Key Investigators==&lt;br /&gt;
* Harvard Medical School: Mohsen Mahvash&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;margin: 20px;&amp;quot;&amp;gt;&lt;br /&gt;
&amp;lt;div style=&amp;quot;width: 27%; float: left; padding-right: 3%;&amp;quot;&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;h3&amp;gt;Objective&amp;lt;/h3&amp;gt;&lt;br /&gt;
&lt;br /&gt;
#:Segmentaion and 3d &lt;br /&gt;
#:reconstruction of pericardial sac&lt;br /&gt;
#: (a thin tissue layer that covers the heart)&lt;br /&gt;
&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;width: 27%; float: left; padding-right: 3%;&amp;quot;&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;h3&amp;gt;Approach, Plan&amp;lt;/h3&amp;gt;&lt;br /&gt;
#:Trying 3dslicer modules &lt;br /&gt;
#:for segmentation &lt;br /&gt;
#:and 3d reconstruction   &lt;br /&gt;
&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;width: 40%; float: left;&amp;quot;&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;h3&amp;gt;Progress&amp;lt;/h3&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;!-- Fill this out before Friday's summary presentations - list what you did and how well it worked. --&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;width: 97%; float: left;&amp;quot;&amp;gt;&lt;br /&gt;
&lt;br /&gt;
==References==&lt;br /&gt;
D’Avila A, Scanavacca M, Sosa E, Riskin JN, Reddy VY. Pericardial anatomy for the Interventional Electrophysiologist. J Cardiovasc Electrophysiol 2003;14:422-430&lt;br /&gt;
&lt;br /&gt;
==Delivery Mechanism==&lt;br /&gt;
&lt;br /&gt;
&amp;lt;!-- List here how you plan to deliver your results to user communities --&amp;gt;&lt;br /&gt;
&lt;br /&gt;
This work will be delivered to the NAMIC Kit as a &lt;br /&gt;
&lt;br /&gt;
#NITRIC distribution&lt;br /&gt;
#Slicer Module&lt;br /&gt;
##Built-in: &lt;br /&gt;
##Extension -- commandline:  &lt;br /&gt;
##Extension -- loadable:&lt;/div&gt;</summary>
		<author><name>Azaitsev</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=2011_Summer_Project_Week&amp;diff=68176</id>
		<title>2011 Summer Project Week</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=2011_Summer_Project_Week&amp;diff=68176"/>
		<updated>2011-06-15T05:36:50Z</updated>

		<summary type="html">&lt;p&gt;Azaitsev: /* Projects */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;  Back to [[Events]]&lt;br /&gt;
&lt;br /&gt;
[[image:PW-MIT2011.png|right|200px]]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
*'''Dates:''' June 20-24, 2011&lt;br /&gt;
*'''Location:''' MIT&lt;br /&gt;
&lt;br /&gt;
==Preliminary Agenda==&lt;br /&gt;
==Agenda==&lt;br /&gt;
&lt;br /&gt;
{|border=&amp;quot;1&amp;quot;&lt;br /&gt;
|-style=&amp;quot;background:#b0d5e6;color:#02186f&amp;quot; &lt;br /&gt;
!style=&amp;quot;width:10%&amp;quot; |Time&lt;br /&gt;
!style=&amp;quot;width:18%&amp;quot; |Monday, June 20&lt;br /&gt;
!style=&amp;quot;width:18%&amp;quot; |Tuesday, June 21&lt;br /&gt;
!style=&amp;quot;width:18%&amp;quot; |Wednesday, June 22&lt;br /&gt;
!style=&amp;quot;width:18%&amp;quot; |Thursday, June 23&lt;br /&gt;
!style=&amp;quot;width:18%&amp;quot; |Friday, June 24&lt;br /&gt;
|-&lt;br /&gt;
|&lt;br /&gt;
|bgcolor=&amp;quot;#dbdbdb&amp;quot;|'''Project Presentations'''&lt;br /&gt;
|bgcolor=&amp;quot;#6494ec&amp;quot;|'''NA-MIC Update Day'''&lt;br /&gt;
|&lt;br /&gt;
|bgcolor=&amp;quot;#88aaae&amp;quot;|'''IGT Day'''&lt;br /&gt;
|bgcolor=&amp;quot;#faedb6&amp;quot;|'''Reporting Day'''&lt;br /&gt;
|-&lt;br /&gt;
|bgcolor=&amp;quot;#ffffdd&amp;quot;|'''8:30am'''&lt;br /&gt;
|&lt;br /&gt;
|bgcolor=&amp;quot;#ffffaa&amp;quot;|Breakfast&lt;br /&gt;
|bgcolor=&amp;quot;#ffffaa&amp;quot;|Breakfast&lt;br /&gt;
|bgcolor=&amp;quot;#ffffaa&amp;quot;|Breakfast&lt;br /&gt;
|bgcolor=&amp;quot;#ffffaa&amp;quot;|Breakfast&lt;br /&gt;
|-&lt;br /&gt;
|bgcolor=&amp;quot;#ffffdd&amp;quot;|'''9am-12pm'''&lt;br /&gt;
|&lt;br /&gt;
|'''9am-11am:''' [[2011 Project Week Breakout Session: Slicer4|Slicer 4 Core Modules Usability Review]]''' [[MIT_Project_Week_Rooms#Star|Star Room]]&lt;br /&gt;
&amp;lt;br&amp;gt;----------------------------------------&amp;lt;br&amp;gt;&lt;br /&gt;
'''11-12pm: &amp;lt;font color=&amp;quot;#4020ff&amp;quot;&amp;gt;Breakout Session:'''&amp;lt;/font&amp;gt; [[2011 Summer Project Week Breakout Session Slicer4 Annotation|Slicer4 Annotations]] (Nicole Aucoin)&amp;lt;br&amp;gt;&lt;br /&gt;
[[MIT_Project_Week_Rooms#Star|Star Room]]&lt;br /&gt;
|'''9am-12pm: &amp;lt;font color=&amp;quot;#4020ff&amp;quot;&amp;gt;Breakout Session:'''&amp;lt;/font&amp;gt;&amp;lt;br&amp;gt; [[2011 Project Week Breakout Session: ITK|ITK]] (Luis Ibanez)&lt;br /&gt;
&amp;lt;br&amp;gt;[[MIT_Project_Week_Rooms#Kiva_32-G449|Kiva Room]]&lt;br /&gt;
|'''9am-4pm: &amp;lt;font color=&amp;quot;#4020ff&amp;quot;&amp;gt;Breakout Session:'''&amp;lt;/font&amp;gt;&amp;lt;br&amp;gt; [[2011 Summer Project Week Breakout Session:OpenIGTLink|OpenIGTLink]]&lt;br /&gt;
&amp;lt;br&amp;gt;[[MIT_Project_Week_Rooms#Kiva_32-G449|Kiva Room]]&lt;br /&gt;
|'''10am-12pm:''' [[#Projects|Project Progress Updates]]&lt;br /&gt;
&amp;lt;br&amp;gt;[[MIT_Project_Week_Rooms#Grier_34-401_AB|Grier Rooms]]&lt;br /&gt;
|-&lt;br /&gt;
|bgcolor=&amp;quot;#ffffdd&amp;quot;|'''12pm-1pm'''&lt;br /&gt;
|bgcolor=&amp;quot;#ffffaa&amp;quot;|Lunch&lt;br /&gt;
|bgcolor=&amp;quot;#ffffaa&amp;quot;|Lunch&lt;br /&gt;
|bgcolor=&amp;quot;#ffffaa&amp;quot;|Lunch&lt;br /&gt;
|bgcolor=&amp;quot;#ffffaa&amp;quot;|Lunch&lt;br /&gt;
|bgcolor=&amp;quot;#ffffaa&amp;quot;|Lunch boxes; Adjourn by 1:30pm&lt;br /&gt;
|-&lt;br /&gt;
|bgcolor=&amp;quot;#ffffdd&amp;quot;|'''1pm-5:30pm'''&lt;br /&gt;
|'''1-1:05pm: &amp;lt;font color=&amp;quot;#503020&amp;quot;&amp;gt;Ron Kikinis: Welcome&amp;lt;/font&amp;gt;'''&lt;br /&gt;
[[MIT_Project_Week_Rooms#Grier_34-401_AB|Grier Rooms]]&lt;br /&gt;
&amp;lt;br&amp;gt;----------------------------------------&amp;lt;br&amp;gt;&lt;br /&gt;
'''1:05-3:30pm:''' [[#Projects|Project Introductions]] (all Project Leads)&lt;br /&gt;
&amp;lt;br&amp;gt;[[MIT_Project_Week_Rooms#Grier_34-401_AB|Grier Rooms]]&lt;br /&gt;
&amp;lt;br&amp;gt;----------------------------------------&amp;lt;br&amp;gt;&lt;br /&gt;
'''3:30-5:00pm: NA-MIC Kit Update''' Slicer4 Developers Guided Tour (Pieper) ([[media:2011 Summer-Slicer4.ppt|Draft Slides]]), Slicer4 Extension Writing Tutorial (Finet, Fillion-Robin)&lt;br /&gt;
&amp;lt;br&amp;gt;[[MIT_Project_Week_Rooms#Grier_34-401_AB|Grier Rooms]]&lt;br /&gt;
|'''1-3pm: &amp;lt;font color=&amp;quot;#4020ff&amp;quot;&amp;gt;Breakout Session:'''&amp;lt;/font&amp;gt;&amp;lt;br&amp;gt; [http://wiki.slicer.org/slicerWiki/index.php/Slicer4:MultiVolumeContainer#Summer_2011_Project_Week_Breakout_Session Slicer4 MultiVolume Containers] (Nicole Aucoin)&lt;br /&gt;
&amp;lt;br&amp;gt;[[MIT_Project_Week_Rooms#Grier_34-401_AB|Star Room]]&lt;br /&gt;
&amp;lt;br&amp;gt;----------------------------------------&amp;lt;br&amp;gt;&lt;br /&gt;
'''3-4pm:''' [[Summer_2011_Tutorial_Contest|Tutorial Contest Presentations]]&lt;br /&gt;
&amp;lt;br&amp;gt;[[MIT_Project_Week_Rooms#Grier_34-401_AB|Grier Rooms]]&lt;br /&gt;
&amp;lt;br&amp;gt;----------------------------------------&amp;lt;br&amp;gt;&lt;br /&gt;
'''4-5pm:''' [[2011 Summer Project Week Breakout Session VTKCharts|VTK Charts]] (Marcus Hanwell)&lt;br /&gt;
&amp;lt;br&amp;gt;[[MIT_Project_Week_Rooms#Grier_34-401_AB|Star Room]]&lt;br /&gt;
|'''12:45-1pm:''' [[Events:TutorialContestJune2011|Tutorial Contest Winner Announcement]]&lt;br /&gt;
&amp;lt;br&amp;gt;[[MIT_Project_Week_Rooms#Grier_34-401_AB|Grier Rooms]]&lt;br /&gt;
&amp;lt;br&amp;gt;----------------------------------------&amp;lt;br&amp;gt;&lt;br /&gt;
'''3-4pm: &amp;lt;font color=&amp;quot;#4020ff&amp;quot;&amp;gt;Breakout Session:'''&amp;lt;/font&amp;gt;&amp;lt;br&amp;gt;[[2011_Summer_Project_Week_Breakout_Session_EMRegistration|Inter-subject Registration for EM segmenter]]&lt;br /&gt;
&amp;lt;br&amp;gt;[[MIT_Project_Week_Rooms#Kiva_32-G449|Kiva Room]]&lt;br /&gt;
|'''1-4pm: &amp;lt;font color=&amp;quot;#4020ff&amp;quot;&amp;gt;Breakout Session:'''&amp;lt;/font&amp;gt;&amp;lt;br&amp;gt; [[2011 Summer Project Week Breakout Session:OpenIGTLink|OpenIGTLink]] &lt;br /&gt;
&amp;lt;br&amp;gt;[[MIT_Project_Week_Rooms#Kiva_32-G449|Kiva Room]]&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|bgcolor=&amp;quot;#ffffdd&amp;quot;|'''5:30pm'''&lt;br /&gt;
|bgcolor=&amp;quot;#f0e68b&amp;quot;|Adjourn for the day&lt;br /&gt;
|bgcolor=&amp;quot;#f0e68b&amp;quot;|Adjourn for the day&lt;br /&gt;
|bgcolor=&amp;quot;#f0e68b&amp;quot;|Adjourn for the day&lt;br /&gt;
|bgcolor=&amp;quot;#f0e68b&amp;quot;|Adjourn for the day&lt;br /&gt;
|&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
==Projects==&lt;br /&gt;
&lt;br /&gt;
* Please make a link for your project to a new page based on the [[2011_Summer_Project_Week_Template| 2011 Summer Project Page Template]]&lt;br /&gt;
&lt;br /&gt;
#valuate the applicability of DICOM RT I/O facility in Slicer (via Plastimatch Extension) for Brachytherapy Planning (Tina Kapur, Greg Sharp, Robert Cormack?)&lt;br /&gt;
#Visualization of b-spline and vector fields (Steve, Danielle, Dominik)&lt;br /&gt;
#[[2011_Summer_Project_Week_Annotation_Module|Annotation Module in Slicer4]] (Nicole Aucoin, Daniel Haehn)&lt;br /&gt;
#[[2011_Summer_Project_Week_RECIST|RECIST Slicer4 module]] (Nicole Aucoin)&lt;br /&gt;
#DicomToNrrdConverter refactoring ( Xiaodong Tao, Mark Scully)&lt;br /&gt;
#[[2011_Summer_Project_Week_normal_consistency_particles|Normal consistency in particle correspondence computation using great circles in principal spheres - Huntington's Disease]], (Beatriz Paniagua, Martin Styner, Sungkyu Jung, Mark Scully)&lt;br /&gt;
#Group-wise Automatic Mesh-Based analysis of CortIcal Thickness (GAMBIT) - TBI (Clement Vachet, Martin Styner, Randi Gollub?)&lt;br /&gt;
#[[2011_Summer_Project__Week_Shape_Analysis_UNC |SPHARM &amp;amp; particles shape analysis - Huntington's Disease]] - Lucile Bompard, Clement Vachet, Beatriz Paniagua, Martin Styner&lt;br /&gt;
#Non-rigid, inter-patient registration of bone masks derived from CT for Head and Neck Cancer Radiation Therapy (Ivan Kolesov, Yi Gao, Gregory Sharp, and Allen Tannenbaum)&lt;br /&gt;
#[[2011_Summer_Project_Week_RSS_for_AFib_Ablation|Robust Statistical Segmentation (RSS) for the Atrial Fibrillation Ablation Therapy]] (Yi Gao, Kedar Patwardhan, Wassim Haddad, and Allen Tannenbaum, Rob MacLeod, Josh Blauer, and Josh Cates)&lt;br /&gt;
#Mass Spectrometry for Brain Tumor Therapy (Behnood Gholami, Nathalie Agar)&lt;br /&gt;
#[[Multimodality Image Registration for TBI]] (Yifei Lou, Danielle Pace, Jack Van Horn?, Marcel Prastawa?)&lt;br /&gt;
#[[2011_Summer_Project_Week_Segmentation_TBI|Segmentation of Longitudinal TBI data]] (Bo Wang, Jack Van Horn, Andrei Irimia, Marcel Prastawa, Guido Gerig)&lt;br /&gt;
#Longitudinal Shape Regression - Huntington's Disease (James Fishbaugh, Guido Gerig)&lt;br /&gt;
#[[2011_Summer_Project__Week_DVH|Dose volume histograms in Slicer]] (Greg Sharp, Nadya Shusharina, Steve Pieper, Csaba Pinter, Tina Kapur)&lt;br /&gt;
#[[2011_Summer_Project__Week_DICOM_RT|Synthetic images, vector fields, RT structures and RT doses in Slicer and ITK]]. (Nadya Shusharina, Greg Sharp, Luis Ibanez, Steve Pieper)&lt;br /&gt;
#[[2011_Summer_Project_Week_Watersheds|Interactive Watersheds Segmentation Module for Slicer  for Atrial Fibrillation and HN Cancer]] (Josh Cates, Ross Whitaker, Steve Pieper, Jim Miller, Nadya)&lt;br /&gt;
#Segmentation of Nerve and Nerve Ganglia in the Spine (Adrian Dalca, Giovanna Danagoulian, Ron Kikinis, Ehud Schmidt, Polina Golland)&lt;br /&gt;
#Image Manifold Learning with Spectral Embedding and Laplacian Eigenmaps (Ramesh Sridharan, Polina Golland)&lt;br /&gt;
#Shapeworks Shape Analysis for Atrial Fibrilliation and HD (Manasi Datar, Beatriz UNC, Mark Scully)&lt;br /&gt;
#Explore the applicability of RSS and Shapeworks for Ventricular Segmentation(Chiara Carminati, ?, ?)&lt;br /&gt;
#[[2011_Summer_Project_Week_Integrate_BRAINSCut_into_Slicer3]](Regina Kim, ... )&lt;br /&gt;
#The Vascular Modeling Toolkit in 3D Slicer 4 (Daniel Haehn, Luca Antiga, Steve Pieper)	&lt;br /&gt;
#[[2011_Summer_Project_Week__LANDWARP_integration|Integration of LANDWARP into interactive registration module]] (Andrey Fedorov, Greg Sharp, Nadya Shusharina)&lt;br /&gt;
#[[2011_Summer_Project_Week_Registration_of_mouse_brains|Registration of mouse brains]] (Francois Budin)&lt;br /&gt;
#ShapeWorks Applications (Manasi Datar, Beatriz Paniagua, Martin Styner, Ross Whitaker, ?)&lt;br /&gt;
#[[2011_Summer_Project__Week_Wireless_Joystick|Wireless joystick controlling medical devices and software (e.g. Slicer4) in the operating room]] (Szymon Kostrzewski)&lt;br /&gt;
#[[2011_Summer_Project__Week_Live_Tracked_Ultrasound|Live Tracked Ultrasound with Slicer4 (Tamas Heffter)]]&lt;br /&gt;
#[http://wiki.na-mic.org/Wiki/index.php/Survey_stealthlink_openigtlink Surveying research teams interested in Open IGT Link support of Stealth Station (Nobuhiko Hata, Ron Kikinis)]&lt;br /&gt;
#DTIPrep - &amp;quot;Study-specific Protocol&amp;quot; based automatic DWI/DTI quality control and preparation - Huntington's Disease (Mashid Farzinfar, Clement Vachet, Joy Matsui, Martin Styner)&lt;br /&gt;
#DTIProcessing - Huntington's Disease (Clement Vachet, Joy Matsui, Martin Styner)&lt;br /&gt;
#Volumetric DTI into Slicer for HD for Tract based roi segmentation (Steve Callahan, Mark Scully, Jim Miller)&lt;br /&gt;
#Nifti Support for Diffusion Tensor Images (Demian)&lt;br /&gt;
#Finishing details on the workflows: DICOM-&amp;gt;Full brain tractography / peritumoral (Demian)&lt;br /&gt;
#Refactoring of the tractography display widget (Isaiah)&lt;br /&gt;
#Laterality (Lauren)&lt;br /&gt;
#Selection for models and bundles post-clustering (Lauren)&lt;br /&gt;
#ROI-based / picking selection of fiber bundles (Maybe one of Sylvain's interns)&lt;br /&gt;
#Adding streamlined tractography to the Finsler front propagation tractography toolkit (Antonio)&lt;br /&gt;
#Add ODF estimation / visualization (Antonio)&lt;br /&gt;
#[[Summer_project_week_2011_Workflows_SOA|Workflows and Service Oriented Architecture Modules for Slicer4 as Extensions]] (Alexander Zaitsev, Wendy Plesniak, Ron Kikinis)&lt;br /&gt;
#[[2011_Summer_Project__Week_DICOM_Networking|DICOM Networking interface for Slicer4]] (Steve Pieper, Nicole Aucoin, Noby Hata)&lt;br /&gt;
#Stenosis Detector in 3D Slicer 4 (Suares Tamekue, Daniel Haehn, Luca Antiga)&lt;br /&gt;
#[[2011_Summer_Project_Week_Spine_Segmentation_And_Osteoporosis_Screening_CT|Spine Segmentation &amp;amp; Osteoporosis Screening In CT Imaging Studies]] (Anthony Blumfield)&lt;br /&gt;
#Slicer module for building an average population HARDI Atlas (Ryan Eckbo)&lt;br /&gt;
#4D Ultrasound (Laurent Chauvin, Noby Hata, Atsushi Yamada)&lt;br /&gt;
#EM Segmentation in 3D Slicer 4 (Daniel Haehn, Dominique Belhachemi, Kilian Pohl)&lt;br /&gt;
#[[NonRigidRegistrationThatAccommodatesResection|Demons Based Non-Rigid Registration that Accommodates Resection in 3D Slicer]] (Petter Risholm, Sandy Wells)&lt;br /&gt;
#[[2011_Summer_Project_Week_re-parameterize_fiber|Re-parameterize fiber tracts for fiber statistics analysis]]&lt;br /&gt;
#[[2011_Summer_Project_Week_Automated_GUI_Testing| Automated GUI Testing (Sonia Pujol, Steve Pieper, Dave Partyka, Jean-Christophe Fillion-Robin, Xiaodong Tao)]]&lt;br /&gt;
#[[2011_Summer_Project_Week_Plastimatch_for_EMSegmenter | Integrating Plastimatch into the EMSegmenter]] (Dominique Belhachemi, Kilian Pohl, Greg Sharp)&lt;br /&gt;
#[[2011_Summer_Project_Week_Customizing_EMSegmenter_pipelines_for_brain_lesions | Customizing EMSegmenter pipelines for brain lesions]] (Dominique Belhachemi, Alexander Zaitsev, Kilian Pohl)&lt;br /&gt;
#[[2011_Summer_Project_Week_Slicer_Extension_for_GLISTR | Slicer extension for GLiome Image SegmenTation and Registration (GLISTR)]] (Andreas Schuh, Daniel Haehn, Kilian Pohl)&lt;br /&gt;
#[[2011_Summer_Project_Week_WMGeometry_Slicer4 | White matter geometry measures in Slicer 4]] (Peter Savadjiev)&lt;br /&gt;
#Internationalization of Slicer (Luping Fang, Steve Pieper, Daniel Haehn, Suares Tamekue, Jean-Christophe Fillion-Robin, Jean-Christophe, Julien Finet, Yiming Ge, Ping Cao)&lt;br /&gt;
#[[2011_Summer_Project_Week__BRAINSFit_new_features_integration|Integrate new features into BRAINSFit]] (Andrey Fedorov, Hans Johnson, Mark Scully)&lt;br /&gt;
#[[2011_Summer_Project_Week_FetchMI:_Slicer_integration_with_XNAT |FetchMI: Slicer integration with XNAT 1.5]] (Misha Milchenko, Wendy Plesniak)&lt;br /&gt;
#[[2011_Summer_Project_Week_ODF_though_Fiber_Counting | ODF computation through fiber counting]] (Yinpeng Li, Ipek Oguz, Martin Styner)&lt;br /&gt;
&lt;br /&gt;
==Background==&lt;br /&gt;
&lt;br /&gt;
We are pleased to announce the 13th PROJECT WEEK of hands-on research and development activity for applications in Image-Guided Therapy, Neuroscience, and several additional areas of biomedical research that enable personalized medicine. Participants will engage in open source programming using the [[NA-MIC-Kit|NA-MIC Kit]], algorithm design, medical imaging sequence development, tracking experiments, and clinical application. The main goal of this event is to move forward the translational research deliverables of the sponsoring centers and their collaborators. Active and potential collaborators are encouraged and welcome to attend this event. This event will be set up to maximize informal interaction between participants.  If you would like to learn more about this event, please [http://public.kitware.com/cgi-bin/mailman/listinfo/na-mic-project-week click here to join our mailing list].&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Active preparation begins on Thursday, April 28th at 3pm ET, with a kick-off teleconference.  Invitations to this call will be sent to members of the sponsoring communities, their collaborators, past attendees of the event, as well as any parties who have expressed an interest in working with these centers. The main goal of the kick-off call is to get an idea of which groups/projects will be active at the upcoming event, and to ensure that there is sufficient coverage for all. Subsequent teleconferences will allow for more focused discussions on individual projects and allow the hosts to finalize the project teams, consolidate any common components, and identify topics that should be discussed in breakout sessions. In the final days leading upto the meeting, all project teams will be asked to fill in a template page on this wiki that describes the objectives and plan of their projects.  &lt;br /&gt;
&lt;br /&gt;
The event itself will start off with a short presentation by each project team, driven using their previously created description, and will help all participants get acquainted with others who are doing similar work. In the rest of the week, about half the time will be spent in breakout discussions on topics of common interest of subsets of the attendees, and the other half will be spent in project teams, doing hands-on project work.  The hands-on activities will be done in 40-50 small teams of size 2-4, each with a mix of multi-disciplinary expertise.  To facilitate this work, a large room at MIT will be setup with several tables, with internet and power access, and each computer software development based team will gather on a table with their individual laptops, connect to the internet to download their software and data, and be able to work on their projects.  Teams working on projects that require the use of medical devices will proceed to Brigham and Women's Hospital and carry out their experiments there. On the last day of the event, a closing presentation session will be held in which each project team will present a summary of what they accomplished during the week.&lt;br /&gt;
&lt;br /&gt;
This event is part of the translational research efforts of [http://www.na-mic.org NA-MIC], [http://www.ncigt.org NCIGT], [http://nac.spl.harvard.edu/ NAC], [http://catalyst.harvard.edu/home.html Harvard Catalyst], and [http://www.cimit.org CIMIT].  It is an expansion of the NA-MIC Summer Project Week that has been held annually since 2005. It will be held every summer at MIT and Brigham and Womens Hospital in Boston, typically during the last full week of June, and in Salt Lake City in the winter, typically during the second week of January.  &lt;br /&gt;
&lt;br /&gt;
A summary of all past NA-MIC Project Events is available [[Project_Events#Past|here]].&lt;br /&gt;
&lt;br /&gt;
== Logistics ==&lt;br /&gt;
*'''Dates:''' June 20-24, 2011&lt;br /&gt;
*'''Location:''' MIT. [[Meeting_Locations:MIT_Grier_A_%26B|Grier Rooms A &amp;amp; B: 34-401A &amp;amp; 34-401B]].&lt;br /&gt;
*'''REGISTRATION:''' Please register [http://guest.cvent.com/d/sdqy0l/4W here].  Payment must be made by credit card.&lt;br /&gt;
*'''Registration Fee:''' $260 (covers the cost of breakfast, lunch and coffee breaks for the week). &lt;br /&gt;
*'''Hotel:''' Boston Marriott Cambridge, Two Cambridge Center, 50 Broadway, Cambridge, MA 02142.  Group rate is $199/night plus tax.  Book [http://www.marriott.com/hotels/travel/boscb?groupCode=jrbjrba&amp;amp;app=resvlink&amp;amp;fromDate=6/19/11&amp;amp;toDate=6/24/11 here] or call 1-617-494-6600 and mention that you are booking in the MIT Room Block.  '''All reservations must be made by May 29, 2011 to receive the discounted rate.'''&lt;br /&gt;
&lt;br /&gt;
== Preparation ==&lt;br /&gt;
&lt;br /&gt;
# Please make sure that you are on the http://public.kitware.com/cgi-bin/mailman/listinfo/na-mic-project-week mailing list&lt;br /&gt;
# The NA-MIC engineering team will be discussing infrastructure projects in a kickoff TCON on April 28, 3pm ET.  In the weeks following, new and old participants from the above mailing list will be invited to join to discuss their projects, so please make sure you are on it!&lt;br /&gt;
# By 3pm ET on Thursday May 12, all participants to add a one line title of their project to #Projects&lt;br /&gt;
#By 3pm ET on Thursday June 9, all project leads to complete [[Project_Week/Template|Complete a templated wiki page for your project]]. Please do not edit the template page itself, but create a new page for your project and cut-and-paste the text from this template page.  If you have questions, please send an email to tkapur at bwh.harvard.edu.&lt;br /&gt;
# By 3pm on June 16: Create a directory for each project on the [[Engineering:SandBox|NAMIC Sandbox]] (Zack)&lt;br /&gt;
## Commit on each sandbox directory the code examples/snippets that represent our first guesses of appropriate methods. (Luis and Steve will help with this, as needed)&lt;br /&gt;
## Gather test images in any of the Data sharing resources we have (e.g. XNAT/MIDAS). These ones don't have to be many. At least three different cases, so we can get an idea of the modality-specific characteristics of these images. Put the IDs of these data sets on the wiki page. (the participants must do this.)&lt;br /&gt;
## Setup nightly tests on a separate Dashboard, where we will run the methods that we are experimenting with. The test should post result images and computation time. (Zack)&lt;br /&gt;
# Please note that by the time we get to the project event, we should be trying to close off a project milestone rather than starting to work on one...&lt;br /&gt;
# People doing Slicer related projects should come to project week with slicer built on your laptop.&lt;br /&gt;
## Projects to develop extension modules should work with the [http://viewvc.slicer.org/viewcvs.cgi/branches/Slicer-3-6/#dirlist Slicer-3-6 branch] (new code should not be checked into the branch).&lt;br /&gt;
## Projects to modify core behavior of slicer should be done on the [http://viewvc.slicer.org/viewcvs.cgi/trunk/ trunk].&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
==Registrants==&lt;br /&gt;
&lt;br /&gt;
Do not add your name to this list- it is maintaining by the organizers based on your paid registration (see Logistics for link)&lt;br /&gt;
#	Nicole	Aucoin	,	Brigham and Women's Hospital&lt;br /&gt;
#	Dominique	Belhachemi	,	University of Pennsylvania&lt;br /&gt;
#	Anthony	Blumfiled	,	Radnostics&lt;br /&gt;
#	Lucile	Bompard	,	UNC NIRAL&lt;br /&gt;
#	Sylvain	Bouix	,	Brigham and Women's Hospital&lt;br /&gt;
#	Francois	Budin	,	UNC NIRAL&lt;br /&gt;
#	Steve	Callahan	,	University of Utah&lt;br /&gt;
#	Joshua	Cates	,	University of Utah&lt;br /&gt;
#	Laurent	Chauvin	,	Brigham and Women's Hospital&lt;br /&gt;
#	Adrian	Dalca	,	MIT CSAIL&lt;br /&gt;
#	Manasi	Datar	,	University of Utah&lt;br /&gt;
#	Colin	Davey	,	&lt;br /&gt;
#	Ryan	Eckbo	,	Brigham and Women's Hospital&lt;br /&gt;
#	Jan	Egger	,	University Hospital of Marburg&lt;br /&gt;
#	Luping	Fang	,	Zhejiang University of Technology, China&lt;br /&gt;
#	mahshid	farzinfar	,	UNC&lt;br /&gt;
#	Andriy	Fedorov	,	Brigham and Women's Hospital&lt;br /&gt;
#	Julien	Finet	,	Kitware Inc.&lt;br /&gt;
#	James	Fishbaugh	,	University of Utah&lt;br /&gt;
#	Greg	Gardner	,	University of Utah&lt;br /&gt;
#	Ronen	Globinsky	,	Yale University&lt;br /&gt;
#	Maged	Goubran	,	Robarts Research Institute&lt;br /&gt;
#	Daniel	Haehn	,	University of Pennsylvania&lt;br /&gt;
#	Mike	Halle	,	Brigham and Women's Hospital&lt;br /&gt;
#	Noby	Hata	,	Brigham and Women's Hospital&lt;br /&gt;
#	Tamas	Heffter	,	Queen's University&lt;br /&gt;
#	Andrei	Irimia	,	University of California, Los Angeles&lt;br /&gt;
#	Hans	Johnson	,	University of Iowa&lt;br /&gt;
#	Ilknur	Kabul	,	Kitware&lt;br /&gt;
#	Tina	Kapur	,	Brigham and Women's Hospital&lt;br /&gt;
#	Ron	Kikinis	,	Brigham and Women's Hospital; Harvard Medical School&lt;br /&gt;
#	Regina	Kim	,	University of Iowa&lt;br /&gt;
#	Szymon	Kostrzewski	,	Ecole Polytechnique Federale de Lausanne EPFL&lt;br /&gt;
#	Dillon	Lee	,	University of Utah&lt;br /&gt;
#	Yinpeng	Li	,	UNC-NIRAL&lt;br /&gt;
#	Yifei	Lou	,	Georgia Institute of Technology&lt;br /&gt;
#	mohsen	mahvash	,	Harvard Medical School (BWH and VA)&lt;br /&gt;
#	Katie	Mastrogiacomo	,	Brigham and Women's Hospital&lt;br /&gt;
#	Joy	Matsui	,	University of Iowa&lt;br /&gt;
#	Dominik	Meier	,	BWH&lt;br /&gt;
#	Mikhail	Milchenko	,	Washington University in St. Louis&lt;br /&gt;
#	James	Miller	,	GE Research&lt;br /&gt;
#	Isaiah 	Norton	,	Brigham and Women's Hospital&lt;br /&gt;
#	Danielle	Pace	,	Kitware&lt;br /&gt;
#	Beatriz	Paniagua	,	University of North Carolina at Chapel Hill&lt;br /&gt;
#	Xenophon	Papademetris	,	Yale University&lt;br /&gt;
#	Kedar	Patwardhan	,	GE Global Research&lt;br /&gt;
#	Steve	Pieper	,	Isomics, Inc.&lt;br /&gt;
#	Csaba	Pinter	,	Queen's University&lt;br /&gt;
#	Wendy	Plesniak	,	Brigham and Women's Hospital&lt;br /&gt;
#	Kilian	Pohl	,	UPenn&lt;br /&gt;
#	Marcel	Prastawa	,	University of Utah&lt;br /&gt;
#	Sonia	Pujol	,	Brigham and Women's Hospital&lt;br /&gt;
#	Martin	Rajchl	,	Robarts Research Institute&lt;br /&gt;
#	Petter	Risholm	,	Brigham and Women's Hospital&lt;br /&gt;
#	Peter 	Savadjiev	,	Brigham and Women's Hospital&lt;br /&gt;
#	Andreas	Schuh	,	University of Pennsylvania&lt;br /&gt;
#	Mark	Scully	,	University of Iowa&lt;br /&gt;
#	Gregory	Sharp	,	MGH&lt;br /&gt;
#	Yundi	Shi	,	UNC-Chapel Hill&lt;br /&gt;
#	Nadya	Shusharina	,	MGH&lt;br /&gt;
#	Ramesh	Sridharan	,	MIT CSAIL&lt;br /&gt;
#	Hao	Su	,	WPI&lt;br /&gt;
#	Suarez	Tamekue	,	Brigham and Women's Hospital&lt;br /&gt;
#	Xiaodong	Tao	,	GE Research&lt;br /&gt;
#	Clement	Vachet	,	UNC Chapel Hill&lt;br /&gt;
#	Antonio	Vega	,	Brigham and Women's Hospital&lt;br /&gt;
#	Gopal	Veni	,	University of Utah&lt;br /&gt;
#	Bo	Wang	,	University of Utah&lt;br /&gt;
#	Demian	Wasserman	,	Brigham and Women's Hospital&lt;br /&gt;
#	Sandy	Wells	,	Brigham and Women's Hospital&lt;br /&gt;
#	Jason 	White	,	Brigham and Women's Hospital&lt;br /&gt;
#	Atsushi	Yamada	,	Brigham and Women's Hospital&lt;br /&gt;
#	Alexander	Yarmarkovich	,	Isomics&lt;br /&gt;
#	Alexander	Zaitsev	,	Brigham and Women's Hospital&lt;/div&gt;</summary>
		<author><name>Azaitsev</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=67805</id>
		<title>Projects:ARRA:SlicerWF</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=67805"/>
		<updated>2011-06-07T17:33:12Z</updated>

		<summary type="html">&lt;p&gt;Azaitsev: /* Progress */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Projects:ARRASuplements|Back to Slicer ARRA home page]]&lt;br /&gt;
= Aim =&lt;br /&gt;
Supplement 3D Slicer and Extensible Neuroimaging Archive Toolkit (XNAT) with workflow management system. Provide integration and interoperability between 3D Slicer, XNAT Services and 3-rd party image processing applications and high performance computing systems. Implement it as within currently developed Structural Planning and Implementation in Neurological Exploration (SPINE) System.&lt;br /&gt;
&lt;br /&gt;
= SPINE Project Documentation =&lt;br /&gt;
[http://cni.bwh.harvard.edu/projects/spine/index.html SPINE Docs]&lt;br /&gt;
&lt;br /&gt;
= Presentations =&lt;br /&gt;
* Segmentation Workflow. PECS University Social Cognition Study.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:SlicerWF_NAC_PECS_Workflow.pdf]]&lt;br /&gt;
* EAB10_ARRA Annual Progress Report Slides.&amp;lt;br&amp;gt;&lt;br /&gt;
[[media:EAB10_ARRA_WF_2011_Zaitsev.ppt | Service Oriented Solutions for 3D Slicer. EAB10_ARRA_WF_2011. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:EAB10_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:NAMIC_ARRA_WF_2011_Zaitsev.ppt  | NAMIC Annual Report 04/2010-03/2011. NAMIC_ARRA_WF_2011_Zaitsev. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:NAMIC_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:Slicer_WF_Slicer4CARMAWorkflow.ppt  | CARMA Workflow. Cardiac Ablation Followup. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:Slicer_WF_Slicer4CARMAWorkflow.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* CARMA Project Beta release Demo Location: http://cni29.bwh.harvard.edu/SlicerWFDemo/index.php&lt;br /&gt;
&lt;br /&gt;
* Segmentation Workflows: Screenshots, scans' and study description : [[File:SlicerWF_EMSegmentProjectsReview.zip]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
= All Hands Meeting Pages =&lt;br /&gt;
* Salt Lake City 2011 Winter [http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA SLC_2011_WorkFlow]&lt;br /&gt;
* MIT 2010 Summer [http://wiki.na-mic.org/Wiki/index.php/Summer_project_week_2010_Workflows_SOA MIT_2010_WorkFlow]&lt;br /&gt;
&lt;br /&gt;
= Research Plan =&lt;br /&gt;
*Create a stand-alone SPINE desktop agent with fully functional data exchange and communication mechanisms towards 3D Slicer and XNAT.&lt;br /&gt;
*Develop Service Oriented Architecture (SOA) SPINE System that will include 3D Slicer image processing modules deployed as web services as well as a workflow management system to orchestrate interaction between 3D Slicer, XNAT, and 3-rd party tools.&lt;br /&gt;
*Implement two-way control and communications between 3D Slicer and SPINE modules.&lt;br /&gt;
*Adapt SPINE System for cluster and grid computing scenarios.&lt;br /&gt;
*Provide with workflow and 3D Slicer web service wrappers editing tools.&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:UseCaseScenarios| Use Case scenarios]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PETCTWorkflow| PETCTWorkflow]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:AgingStudySegmentation| AgingStudySegmentation]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:TwoTensorTractography| TwoTensorTractography]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:LongitudinalMultimodalityRegistrationSuite| LongitudinalMultimodalityRegistrationSuite]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:MigrationJavaClients2QT| MigrationJavaClients2QT]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PediatricMSSegmentation| PediatricMSSegmentation]]&lt;br /&gt;
*[[DBP3:Utah:RegSegPipeline| MRI-based study and treatment of atrial fibrillation]]&lt;br /&gt;
&lt;br /&gt;
= Application Server / Workflow Engine Downloads =&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:WFEngineDownloads| Download Links]]&lt;br /&gt;
&lt;br /&gt;
=Key Personnel=&lt;br /&gt;
* Charles Gutmann, MD., 4%,  9-17-2009 through 9-16-2011&lt;br /&gt;
* Alexander Zaitsev, Ph.D., 75%, 9-17-2009 through 9-16-2011 &lt;br /&gt;
&lt;br /&gt;
=Annual Progress Statements =&lt;br /&gt;
'''2010-11''' &amp;lt;br&amp;gt;&lt;br /&gt;
The  April 2011 – March 2011 period was devoted on developing portable workflow solutions that can be deployed on end-users' workstations or notebooks with minimal or no system administration activities. This is in contrast to the server-side deployment. The following scenarios had been deployed and used for actual projects that require the following types of workflows: PET/CT registration and computation of biomarker driven brain physiological activities, Brain MRI Images segmentation,  MRI and MRI Angiography images pre-processing for cardiac ablation outcome estimation. Some  workflows (like EM Segmentation) had been utilizing various scenarios, some research projects  (like evaluation of chemotherapy outcome) require two types of workflows to assess physiological and structural changes. Starting from the 4th Quarter of 2011, the migration project had been emerged in order to embed Workflow GUIs into newly developed Slicer4 Suite. The existing rich client Java GUI applications are being re-written as C++/QT Sliceletts units, new modules (such as cardiac ablation project support) are had been written from scratch. The latter are being deployed from the Slicer4 GUI and act at a liaison between Slicer4 and Application Server containing  workflow and Slicer modules deployed as services. The feedback from the end users indicates that Workflow approach for the complex processing improves productivity, aids to the processing standardization and contributes to the overall experience using 3D Slicer&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
=Quarterly Progress=&lt;br /&gt;
&lt;br /&gt;
* NAMIC Annual Progress Slides (April 2010 - March 2011):&lt;br /&gt;
&lt;br /&gt;
* '''1st Qtr, 2011''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study: Second release is under testing by end-users. &lt;br /&gt;
*** Added MRI registration to aid ROI drawing on PET scans&lt;br /&gt;
*** Improved SUV results reporting and added flexibility to update ROI lookup table&lt;br /&gt;
*** Automated EM Segmentation of MRI images for computing SUVs for white matter, CSF, and whole brain (80% completion)&lt;br /&gt;
*** Integration with SPECTRE scull stripping module (70% completion) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** EM Segmentation: Automated WF Pipelines are created &amp;lt;br&amp;gt;&lt;br /&gt;
*** Flexible atlas selection (Pediatric, etc) feature added&lt;br /&gt;
*** Workflows implemented for EM Segmenter 3.6.2 and 3.6.3 (1st Qtr 2011 release)&lt;br /&gt;
&lt;br /&gt;
** Cardiac ablation results follow-up: Workflow for registration and ROI selection of cardiac MRI and MR Angiography &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Wrokflow and Web Services for prospective DTI tractography modules (currently written as Matlab modules at PNL) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Web Services for SPECTRE Scull stripping module&lt;br /&gt;
*** Accuracy and performance tuning&lt;br /&gt;
*** 50% completion&lt;br /&gt;
&lt;br /&gt;
** Migration Front End GUI to Slicer4/QT:&lt;br /&gt;
*** EM Segmentation&lt;br /&gt;
*** Cardiac Ablation Study&lt;br /&gt;
&lt;br /&gt;
** DICOM Uploader and Desktop Browser for XNat Image repository (alpha version - tested for MGH MS Center studies, proposed to use with MI2B2 Clients and Services)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''4th Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study and EM Segmentation for Aging Study are deployed at end-user sites and actively used for research. &lt;br /&gt;
** Adopted EM Segmentation preprocessing pipeline for HIV Study: high resolution SPGR images, integration with FreeSurfer brainmask extraction outputs; integration of Slicer SPECTRE module for brainmask extraction is in progress.&lt;br /&gt;
** The following post-release upgrades had been implemented based on end-user feedback: Application Server basic controls are performed from Rich Client GUI as alternative to traditional IT administration activities. The controls are implemented on point-and-click bases and include web services and workflow application deployment and upgrades, application server start and stop as well as warning end user when the server is not accepting request.&lt;br /&gt;
** Added DICOM downloads and results uploads of PET/CT pipelines from and to XNat Repository&lt;br /&gt;
** Created Services and Workflow for Matlab Prototypes modules. Case Study: tractography for DTI images&lt;br /&gt;
** Extended XNAT integration services:&lt;br /&gt;
*** Browsing capabilities of XNat data repository from the Workflow Applications&lt;br /&gt;
*** Improved DICOM upload and download performance&lt;br /&gt;
*** Added Metadata organizing services for uploaded DICOM images: header data extraction, image snapshots creation. &lt;br /&gt;
** Started project for Rich Client GUI migration from Java desktop application to build into SLicer4 QT modules. This affects mostly front-end GUI and has the following approaches: distribution with the Slicer4, end-user will select desired workflow application from Slicer4 menu while QT-written modules provide with the same functionality as Java Rich Clients. Case Study for the Migration process: registration suite for longitudinal studies that include multi-modality images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* '''3d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Concentrated on building downloadable workflow applications that could run both in desktop (new) and server environment, and that require minimum IT administrative resources. The desktop deployment is in compliance with Slicer3 general deployment concept.&lt;br /&gt;
*** The following use case scenario had been chosen: PET/CT image processing for longitudinal studies, EM Segmentation for longitudinal Aging Study.&lt;br /&gt;
** Released workflow application for PET/CT image processing for longitudinal studies. Provided end users with training and documentation.&lt;br /&gt;
*** The PET/CT processing workflow was designed to be a general application used whenever both structural patterns and metabolic activities are within the research scope. &lt;br /&gt;
*** The desktop version is tuned to use minimal computer resources, so the automates processing instances do not interfere with human activities. Automated activities may include, for example, registration and PET scan's standard uptake values computing, and manual human activities may include image cropping, quality control, and labeling voxels of interest.&lt;br /&gt;
** Core services and EM Segmentation preprocessing workflow was build for retrospective Aging Study. Tuned the Slicer3 webservices for processing low grade images acquired in mid 90s. Entire workflow is implemented with Slicer3 only modules and can be deployed locally and on the servers. Usage of Service Oriented Architecture (SOA) as a core technological approach allowed reusing most of the web services that had been build for PET/CT project. &lt;br /&gt;
** Continued embedding Slicer3 application and modules into previously released processing pipelines: replaced MIPAV with Slicer3 GUI for lesion assessment step in the multi-center Pediatric MS Cohort image processing &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''2d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Completed Social Cognition Workflow Implementation. This includes EM Segmetnation pre- and post-processing pipelines, data tracking, and integration with 3d party image processing utilities, as well as processing results acquired manually with Slicer GUI.  &lt;br /&gt;
** Multi-modality image registration and ROI selection/alignment workflow for longitudinal studies. &lt;br /&gt;
*** Use case: PET/CT image processing for longitudinal studies. &lt;br /&gt;
*** Build portable library of Slicer modules as web services and workflow that are deployed and run on a end-users' worksatations without utilization of SPL and other servers. The web services include novel Slicer3 modules, such as BRAINSFit and BRAINSResamle &lt;br /&gt;
*** Started working with Slicer3 developers on Slicer 3.8 GUI wizard to communicate with workflow instances.&lt;br /&gt;
** Participated at NA-MIC Summer 2010 Project Week: [[Summer_project_week_2010_Workflows_SOA]]&lt;br /&gt;
&lt;br /&gt;
=Progress=&lt;br /&gt;
* June 3, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Deployed on end-user's machine&lt;br /&gt;
* TODO next week: fix SUV results consolidation issue (when MRI segmented ROI got SUV computed for some subjects, only those subjects' SUVs are being added into consolidated report. &amp;quot;Raw&amp;quot; SUV values per subject are generated as expected)  &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 27, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Ready for deployment. New Features: hemispheres EM Segmentation, automated ICC/brainmask extraction using EM Segmenter, fixed controls for MRI conversion and registration&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 20, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General / PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Hemispheres EM Segmentation - adjusted for required label lookup table&lt;br /&gt;
* Use cases added for EM Segmenter General Project: http://www.slicer.org/slicerWiki/index.php/EMSegmenter-Tasks#EMSegmenter_use_cases&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SPECTRE Scull Stripping&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* The new version to be tested on coming week (After PETCT MRI processing migrated to Hemispheres scenario )&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* May 13, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General / PETCT V1.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Hemispheres EM Segmentation - technically works with labal values hardcoded in Slicer EM Segmenter - need to add manual label value edition step&lt;br /&gt;
* PETCT WF Cut for Java GUI (Pending Hemispheres label update completion). Next release will be in QT4.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* May 6, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (QA of EM Segmenter module, work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* April 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Open Discussion for Packaging WF QT Modules as Slicer4 extensions (waiting for SOPs)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review supported projects http://wiki.na-mic.org/Wiki/index.php/File:SlicerWF_EMSegmentProjectsReview.zip &lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (required by Study)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Slicer Modules General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Standardizing Crop Volumes Output (with A. Fedorov's module). Review for required updates of existing product (PET/CT, CARMA)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Open Discussion for Packaging WF QT Modules as Slicer4 extensions (waiting for SOPs)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review supported projects http://wiki.na-mic.org/Wiki/index.php/File:SlicerWF_EMSegmentProjectsReview.zip &lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (required by Study)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Slicer Modules General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Standardizing Crop Volumes Output (with A. Fedorov's module)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 22, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Beta release ready. Demo Location: http://cni29.bwh.harvard.edu/SlicerWFDemo/index.php&lt;br /&gt;
* TODO: Tutorial. Original inputs copy/renaming&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 15, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Adding App server auto-config features&lt;br /&gt;
* Finalizing the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 08, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Second release beta build tested on cosutmer side &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review registration quality (with Dr. Meier). Angiography images' Resampling tuned. &lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 01, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the second release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
XNat Integration&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* (Java) GUI for Project Browsing and DICOM Series Upload. Post-upload DICOM processing tested and debugged&amp;lt;br&amp;gt;&lt;br /&gt;
* Ready for integration with mi2b2 client.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Migrated to Latest Slicer 3.6.3 stable release: only the Input scene had to be updated, the API remained the same&lt;br /&gt;
* Tested EM Segmenter with CMTK4Slicer extension - processing takes to much time on Linux_64bit machine, rolled back to BRAINSFit registration. When used on Mac OS X build, the Slicer could not start (bug report 1126).&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SPECTRE Scull Stripping:&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Testes for various use cases: the module is extremely sensitive to T1 MRI quality (does not work for most MRIs from PET/CT project&lt;br /&gt;
* TODO next week: check for FLAIR images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Slicer4 QT GUI and Cropping activity in progress.&amp;lt;br&amp;gt;&lt;br /&gt;
* Tried direct MRA to MRA registration option: resampling with LMRI registration transforms works better.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Extra VOI labels revised&lt;br /&gt;
* Debugging of SUV results' renormalization step&lt;br /&gt;
* TODO: ICC extraction / whole brain total uptake computing; EM Segmentation for R_WM, L_WM SUV computing and BPH estimation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SCULL STRIPPING/SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Installed and tested CLI option on Linux_64bit platform&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Workflow interruption before BSPline registraton: BPEL Module completed. Slicer4 QT GUI and Cropping activity in prorgess.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Implemented and Tested with end-users proposed changes: denormalization of SUV results, adding more VOI labels, added FLAIR MRI in addition to T1s for VOI drawing&lt;br /&gt;
* Tested manual ICC extraction using PET scans: works satisfactory with island removal and cropping followed by threshold level labeling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4&lt;br /&gt;
* Change proposed: interrupt workflow after affine registration and have user crop the VOI. This is to prevent excessive deformations for BSpline registration and resampling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4. User has option to choose the atlas that fits better for the given subject (NOTE: hardcoding must be rewritten for atlas linking)&lt;br /&gt;
* PETCT test - the problem is that T1s are low resolution and with contrast. Proposed using T1s without contrast&lt;br /&gt;
* PETCT change request: users wants to compute SUV for entire ICC. Had demo how to segment brainmask/ICC using PET scan. The derived brainmask label can be used for SUV computation.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - cmpleted&lt;br /&gt;
* Sample cases run - excessive deformation after BSpline registration hase&lt;br /&gt;
* Next week plan - pull tuning controls to front-end of pipeline API, start working of QT module for CARMA registration&lt;br /&gt;
* May consider other than BRAINSFit registration modules&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Design plan for change request: more VOI labels, add FLAIR in addition to T1 for VOI drawing, T1s segmentation&lt;br /&gt;
* Tested segmentation for sample cases - artifacts from poor quality MRIs lead to exclusion of parts of ICC from segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Completed troubleshooting of EMSegmenter module calling from Java (need TCL libs to be pulled from Slicer environment)&lt;br /&gt;
* Tested EMSegmenter autoruns for HIV and Pediatric MS patiens. Work as expected, subject to improvement of PED MS case segmentation by building better skull/neck/air atalses&lt;br /&gt;
* Suggested usage of two subsets of atalases: with and without neck. The Subject MRIs have to be cropped accordingly or best fit atlas has to be selected&lt;br /&gt;
* Made no-neck cropped atlas collection for default EMSegmenter scenario&lt;br /&gt;
* Tested with PET/CT study MRI cases - see above &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - in progress&lt;br /&gt;
* Next week goal - have back end processing ready&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Longitudinal Study&lt;br /&gt;
* Added MRI registration to the pipeline&lt;br /&gt;
* Troubleshooting of complex XML schema issues on Linux machines (some modules working on MAC do not work on Linux). As a workaround - did not include MRI convert and register part into base BPEL module. Used separate services (transparent for end-user)&lt;br /&gt;
* TODO next week for change request completion: explicit pixel type casting for MRI in BRAINSFit, VOI MRML scene update (currently MRI added on top of schema)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* February 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipeline for Pediatric MRI. Same scenario as for HIV Project, icbm pediatric atlases (Completed, verified)&lt;br /&gt;
* Collected NIH healthy brain development atlases: various age ranges from 4.5 to 18 yo. Converted to Slicer readable format &lt;br /&gt;
* Work on web services for the new automated EM Segmenter module (release Nov 10 - current). Verified task completion both for adult and pediatric images. Discussed tuning parameters for work load balance on workstations.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Started working on MRI registration to the reference CT scans. &lt;br /&gt;
* Design specs for optional White Matter segmentation for SUV computing.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* February 4, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipelines for Pediatric MRI (in progress)&lt;br /&gt;
* Adapting Pediatric T1 atlases for &amp;quot;Human Brain&amp;quot; build-in EM Segmentation wizard (in progress)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 28, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Verifying EM Segmenter module for latest builds and HIV/PED MS Studies (report pending)&lt;br /&gt;
* Work with SPECTRE module developers with pediatric MRI brainmask extraction&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* January 21, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Compiling plan for WF FrontEnd GUI migration to Slicer4/QT Widgets&lt;br /&gt;
* Preparing for annual progress report&lt;br /&gt;
&lt;br /&gt;
* January 14, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI: Integrated into the Slicer4 as Slicelet (or thin Client)&lt;br /&gt;
* Participation at AHM-2011, discussing integration of SPECTRE module and updated approach to EM-Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA&lt;br /&gt;
&lt;br /&gt;
* January 7, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* HIV project workflow delivered. Major additions relate to user convenience: &lt;br /&gt;
- Project-specific parameter settings, importing T1s and brainmasks from FreeSurfer outputs with conversion to NIFTI, resampling brainmask to original scans and automatied subject addition.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Follow up with end user: need to add MRI scans, if available, addition and registration to CT in order to ease VOI drawings.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
 &lt;br /&gt;
* December 31, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Follow-up with user Experience for AGING Study Segmentation (Positive feedback)&lt;br /&gt;
* Target date for HIV project delivery - next week&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Self-training for QT widget development&amp;lt;br&amp;gt;&lt;br /&gt;
* Outlined Workflow Rich Clients migration strategy from Java to QT/Slicer4:&amp;lt;br&amp;gt;&lt;br /&gt;
** Use Java Stubs (similar to SPECTRE integration) or file binding for envocation of workflow pipelines. (See SOAP remark below)&lt;br /&gt;
** Direct Web Servisec calls must be wrapped into REST protocol. The reason: NON-commerchial QT kit does not include SOAP protocol for web servises.&lt;br /&gt;
** The GUI will be implemented as page widget or QT dialog GUI forms called from within Slicer4.&lt;br /&gt;
** Communications between Slicer4 and WF GUI will be set via child-parent and signal-slot relations&lt;br /&gt;
* Worked on a Prototype for Basic EM Segmentation QT widget (70% complete). Will work on integrtion with SLicer4 during the AHM-2010&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
XNAT Integration&lt;br /&gt;
* Debugged XNAT RESTFul API usage for uplaoding DICOM series followed by header data extraction and image snapshots creation&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Added compensation for failed atlas registration (subject for old poor quality pseudo-T1 images): blank probability maps are created in case of failure.&lt;br /&gt;
* Data preparation module for FreeSurfer data import near completion. Expected time for deployment at end-users workstations - first week of January&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Discussed strategy for EM Segmentation pipeline solutions collection (K. Pohl, R. Kikinis)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* RE-using the same core workflow as for 1-channel EM Segmentation of AGING STUDY cases&lt;br /&gt;
* Added data input preparation module: ICC label mask preparation and skull-stripping based on FreeSurfer brainmask output volume.&lt;br /&gt;
* Two-channel EM segmentation pipeline (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE / GENERAL Development &amp;lt;br&amp;gt;&lt;br /&gt;
* Worked on plans for migrating fro rich workflow Java clients to embedded workflow windows inside the Slicer.&amp;lt;br&amp;gt;&lt;br /&gt;
The embedded workflow management clients are to be implemented with QT/PyQT toolkits&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
INTEGRATION WITH XNAT:&amp;lt;br&amp;gt;&lt;br /&gt;
* Automated DICOM series upload with triggering DICOM headers parsing at XNat site (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress. &lt;br /&gt;
- Results upload to XNat (Completed) &amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat based on user's input (Project + Subject + PET or CT session / scan) (Completed)&amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat - perfomance boosting solution for downloads found , web services services are created, relinking for the client side in progress &amp;lt;br&amp;gt;&lt;br /&gt;
- Xnat querying for subjects and automated subject addition into the workflow (In Progress) &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-segmentation module added for auto correction of segmentation results. Particularly - relabeling CSF voxels segmented as Air inside the intracranial cavity. This was requested by end-users after processing images with zero-signals in CSF voxels &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting automated dual-echo DICOM images conversion and split into two NRRD volumes&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT / EM Segmentation pipeline:&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting memory allocation issues for scull-stripping module SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
COPD Project:&amp;lt;br&amp;gt;&lt;br /&gt;
* Benchmark test for accelerated DICOM downloads from XNat (remoote XNat Central server): we can handle at least 6 cases (4 CT scans in each) per hour, which is compatible with current workload quotes on SPL cluster processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* December 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Deployed Version 1. &amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Test project chosen as a closest match to registration scenario: Pediatric MS Cases from MGH - requires periodic image preview for different &lt;br /&gt;
modalities taken from vaious time points. Label maps for VOIs resampling is also required.&lt;br /&gt;
&lt;br /&gt;
* November 26, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user. Version 1 is complete&amp;lt;br&amp;gt;&lt;br /&gt;
* Started working on integration with XNat&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on input data organizing modules&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 19, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user (70% done)&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Universal Registration Workflow for Longitudinal Studies - design specs in progress&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 12, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Minor tuning to EM Segmentation template as of users' feedback&lt;br /&gt;
* Users started using the workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed input data conversion from Genesis to Slicer native or NIFTI format. Our help may be needed in input data organizing.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Tuned application according to co-laborators (PNL) needs&amp;lt;br&amp;gt;&lt;br /&gt;
* The webservices and BPEL workflow application are tested ready to accept computation requests from PNL case tracking system &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Discussed Universal Registration Workflow for Longitudinal Studies&lt;br /&gt;
* Started the thread about possible cooperation with Children hospital's image processing pipelines and integration with Xnat &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 5, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Webservices and workflow pilot project created and deployed on Psychiatry Neuroimaging Laboratory subnet &amp;lt;br&amp;gt;&lt;br /&gt;
* The V.1.0 deployment is scheduled for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 29, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Most of functionality is completed. Some volume statistics post processing is pending&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL EM SEGMENTATION Pipeline: &amp;lt;br&amp;gt;&lt;br /&gt;
* The SPECTRE scull stripping module. Started integration into EMS workflow. Made some test runs from Slicer GUI&amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Identified as a candidate for Workflow Application&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 22, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* All back-end functionality are implemented&amp;lt;br&amp;gt;&lt;br /&gt;
* EM Segmentation scene usability is confirmed by end-user&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for next week: add Label Statistics computation for CSF/Brain/ICC &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 15, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* The latest (October) builds of Slicer 3.6.2 produced acceptable results. This was verified by the target users. The EM Segmentation will be performed on Slicer 3.6.2 or later&amp;lt;br&amp;gt;&lt;br /&gt;
* The new Web services had been created and added to the pipeline as optional processing steps: Biasfield correction (implement novel N2ITKBiasFieldCorrection module) and Volume's scalar datatype casting (as workaround for Biasfield correction module not preserving image scalar datatype - the bug is filed) &amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed the Front-End GUI design with target users. The design pattern is taken from the PETCT project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 8, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-deployment support. Tuned CT registration as of user's feedback.&lt;br /&gt;
* Adapting to the Single Slicer build: Slicer 3.6.2. Found label duplicates in the label lookup table - will ask user if it's tolerable. Waiting for the Slicer 3.6.2 build that contains all required modules. Rolling back label tag appending code for SUVs - the latest Slicer build appends the tags.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Resumed development. The priorities are set for usage of Slicer 3.6.2 - subject for EM Segmentation scene tuning. Continued coding for Scene creation for Slicer 2.8 - as a backup option for ongoing research project.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 1, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized V1.0 release based on end-user feedback: updates relate mostly to error proofing and SUV values representation&lt;br /&gt;
* Post-deployment support. Users pre-processed first set of patients &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* September 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* System deployed and tested at End Users' site.&amp;lt;br&amp;gt;Users are trained to perform all tasks required by the workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
* Got positive feedback with suggestions on Slicer Scenes' layouts improvement and PET scans' SUV (standard uptake values) results display&lt;br /&gt;
* Two distribution packages are assembled: Lunix and MAC OS versions. The difference in two packages is in specific Slicer3.6/3.7 builds - subject to Slicer Linux builds debugging.&amp;lt;br&amp;gt; As a workaround for Linux deployment - multiple Slicer builds are used to perform various tasks (registration, opening editing scenes in Slicer, SUV computing)&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for coming week - finalize V1.0 release based on end-user feedback&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Embedded SUV computations into the workflow (as system calls - will be translated into web service later)&amp;lt;br&amp;gt;&lt;br /&gt;
* Pre-release demo for end users.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Create and debug EM Segmenter scenes template for Slicer 3.6 and 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* September 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation - workflow pipeline and deployment verified&amp;lt;br&amp;gt;&lt;br /&gt;
* Tested EM Segmentation scenes within Slicer 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
* Started migration of EM Segmentation to Slicer 3.6. Discovered issues had been reported to EM Segmenter module designers &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* August 29 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation completed. Preprocessing Pipleine completed 80% (subject for input registration parameters tuning) &amp;lt;br&amp;gt;&lt;br /&gt;
* Most webservices (for registration and resampling steps) had been taken and re-used from PET/CT ROI/Longitudinal Study - showing the advantage of service-oriented software design and deployment.&lt;br /&gt;
* Continued on distribution and deployment of the service/workflow applications: on PET/CT and AGING STUDY projects.&lt;br /&gt;
&lt;br /&gt;
PEDIATRIC Multiple Sclerosis Cohort. Support of multi-center distributed processing project&amp;lt;br&amp;gt;&lt;br /&gt;
* Introduced Slicer 3.6 for the MS Lesion Assessment step performed at Mayo Clinic. Images are being transferred from image repository at BWH and automatically opened and arranged within Slicer GUI for reading.  This was replacement of Client GUI using MIPAV that stopped working on new computers at Mayo Clinic.&lt;br /&gt;
The images are being loaded via generated MRML Scenes same way as in PET/CT and AGING STUDY projects &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* August 22 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Preprocessing pipeline merge with SUV computations &amp;lt;br&amp;gt;&lt;br /&gt;
- QA for SUVs computation was performed by Wendy Plesniak for images with known uptake values. &amp;lt;br&amp;gt;&lt;br /&gt;
- Discovered that image cropping step (not related to automated registration pipeline and SUVs computing) smoothes the images by doing interpolation when used with default settings. Got suggestions from Steve Piper using Nearest-Neighbor interpolation (&amp;quot;no interpolation&amp;quot;) for a time being&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
- This is the new project candidate. Requested for the images with failed manual segmentation and/or segmentation with FreeSurfer. The EM Segmentation run showed most acceptable results on one of the problem images back in February &amp;lt;br&amp;gt;&lt;br /&gt;
- The workflow will be developed and deployed similar to PET/CT ROI Longitudinal study approach - all preprocessing steps will be done with Slicer modules, all runs will be performed on local end-user machines.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
 &lt;br /&gt;
&lt;br /&gt;
* August 15 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- First 5 cases with 3-4 time points preprocessed for SUVs computation&lt;br /&gt;
&lt;br /&gt;
* August 8 2010&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Testing of installation and operation at users' site (Performed by Wendy Plesniak)&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* July 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Delivered beta version of registration pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
- Prepared installation and user manuals &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* June 11, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Registration modules completed &amp;lt;br&amp;gt;&lt;br /&gt;
- Irregular cases registration problem solved (when whole body and brain only scans are mixed for a timepoint)&amp;lt;br&amp;gt;&lt;br /&gt;
- Live demo of case setup and registration workflow for end users. Real case with 4 timepoints used&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Coming week plans&amp;lt;br&amp;gt;&lt;br /&gt;
- Adjust workflow based on end users' feedback&amp;lt;br&amp;gt;&lt;br /&gt;
- Integration with SUVs computing for PET scans&amp;lt;br&amp;gt;&lt;br /&gt;
- GUI for workflows dispatching and data organizing&amp;lt;br&amp;gt;&lt;br /&gt;
- (TBD) Integration with 4D time series analysis Slicer module&amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
* May 28, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- Migration to the latest Slicer 3.6 release candidate &amp;lt;br&amp;gt;&lt;br /&gt;
- Added webservice for new registration module: BRAINSFit &amp;lt;br&amp;gt;&lt;br /&gt;
- Test runs for new patients with 4 timepoints' scans &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Plans for next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI &amp;lt;br&amp;gt;&lt;br /&gt;
- processing workflow demo for end user &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 21, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Pilot version of portable web services and automated workflow tested: &amp;lt;br&amp;gt;&lt;br /&gt;
Linux: workflow and visual review passed&amp;lt;br&amp;gt;&lt;br /&gt;
Stress test for 25 timepoints passed &amp;lt;br&amp;gt;&lt;br /&gt;
MAC OS: workflow passed, visual review failing when PET/CT images are loaded into GUI simultaneously (bug report submitted)&amp;lt;br&amp;gt;&lt;br /&gt;
Windows: need to adapt command line modules and workflow management system to sygwin environment&amp;lt;br&amp;gt;&lt;br /&gt;
Plans for next week: integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI&lt;br /&gt;
&lt;br /&gt;
* May 7, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Selected registration and resampling modules with more precise and stable outputs. &amp;lt;br&amp;gt;&lt;br /&gt;
Started building portable web services and automated workflow &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 30, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- manual walk through the processing steps: ROI cropping, registration/resampling, PET pharmaceutical DICOM data retention. &amp;lt;br&amp;gt;&lt;br /&gt;
- testing workflow and web services packages distribution to end-users' machines&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* April 23, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : testing various registration and re-sampling algorithms (work in progress)&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation: as of collaborators' request, run existing EM Segmentation workflow for older low resolution pseudo-T1 images. The EM Segmentation works for those images with manual sampling. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 16, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
  Social Cognition Study: started Cortical Thickness Measurement module build (bases on NA-MIC ARCTIC pipeline) &amp;lt;br&amp;gt;&lt;br /&gt;
  PET/CT ROI/Longitudinal Study Registration : Design specs, PET-to-CT images registration tests on training data. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 9, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. GUI update based on end-user experience.&amp;lt;br&amp;gt;&lt;br /&gt;
User request: automated label maps' volumes calculation (Currently possible from Slicer3 GUI)&amp;lt;br&amp;gt; &lt;br /&gt;
PET/CT ROI Project. Initial design specs discussion with end-users and co-developers&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure&lt;br /&gt;
Verification of segmentation workflow GUI: from registering new case to reviewing results&amp;lt;br&amp;gt;&lt;br /&gt;
Cross study test of segmentation workflow: MGH/MS Center data - success,  HIV Project data - some EM Segmentation scene tuning is needed &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*&lt;br /&gt;
* April 2, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. Segmentation workflow completed&amp;lt;br&amp;gt;&lt;br /&gt;
* Coming Week plans:&amp;lt;br&amp;gt;&lt;br /&gt;
- Document Segmentation Workflow. Follow up with end users &amp;lt;br&amp;gt;&lt;br /&gt;
- Start with Cortical Thickness and ROI-in-longitudinal studies workflows&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* March 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All essential processing and workflow interaction clients are ready.&amp;lt;br&amp;gt;&lt;br /&gt;
- Completed segmentation for 10 out of 50 patients. The remaining cases will be finalized upon manual lesion segmentation and QC verification of WM/GM/CSF and Deep GM segmentation's. &amp;lt;br&amp;gt;&lt;br /&gt;
- TODO next week: refine QC GUI and data tracking / progress monitoring schema. &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&amp;lt;br&amp;gt;&lt;br /&gt;
- New Slicer3 web services added: re-slicing with reference image volume, casting image scalar type &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
* March 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Segmentation maps Merging Services for GM/WM/CSF (Slicer EM Segemnter), Lesion (Slicer, Manual), and Deep GM (FreeSurfer)  &amp;lt;br&amp;gt;&lt;br /&gt;
- Deep GM segmentation pipeline adopted as optional service for Social Cognition Study (22 out of 50 cases processed) &amp;lt;br&amp;gt;&lt;br /&gt;
- (In progress) GUI client for Launching Segmentation results merging with optional Deep GM segmentation with FreeSurfer &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- Complete GUI Client for Segmentation result merging &amp;lt;br&amp;gt;&lt;br /&gt;
- Progress Monitoring services for entire Study processing: EM Segmenter Preprocessing, EM Segmentation, Lesion Segmentation (including human activities assignments), Deep GM segmentation, and results consolidation. &amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* March 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All 50 cases went through &amp;quot;basic&amp;quot; One-channel EM segmentation (GM/WM/CSF) &amp;lt;br&amp;gt;&lt;br /&gt;
- Basic pipeline start-up command line client created: user has two options - request brainmask extraction or provide with previously extracted brainmask for a given subject &amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison of GM/WN/CSF performed for Slicer EM Segmenter and FreeSurfer recon-all (used with default settings). &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmenter provides more accurate output &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmentation pipeline runs faster (40 minutes vs 12 hrs when no brainmask extraction requested) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO:&amp;lt;br&amp;gt;&lt;br /&gt;
- merging modules for automatic 1-channel EM segmentation and manual lesion segmentation &amp;lt;br&amp;gt;&lt;br /&gt;
- Emerge Cortical Thickness pipeline project: use NAC ARCTIC processing steps and modules &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Selected stable EM Segmentation scenario: White Matter, Gray Matter, and Cerebrospinal Fluid &amp;lt;br&amp;gt;&lt;br /&gt;
- First 16 cases are segmented for selected scenario. Nine more cases are preprocessed for EM Segmentation.&amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison to segmentation with FreeSurfer showed better accuracy for Slicer2 EMSegmenter &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure &amp;lt;br&amp;gt;&lt;br /&gt;
- Three prerpcocessed cases failed during volume ICC masking with in-house build utility. Evaluated switching to Slicer3 Mask and island removing modules.&amp;lt;br&amp;gt;&lt;br /&gt;
- Initial design specs discussion for cortical thickness measurement pipeline. ARCTIC pipeline selected. ARCTIC preprocessing steps signifficantly overlap with EM Segmentation preprocessing workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
  &lt;br /&gt;
* February 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: &amp;lt;br&amp;gt;&lt;br /&gt;
A) parameters tuning for EM Segmenter itself (work with EM Segmenter developer), template scenes creation &amp;lt;br&amp;gt;&lt;br /&gt;
B) update preprocessing pipeline - deep gray matter atlases included &amp;lt;br&amp;gt;&lt;br /&gt;
C) test and debug preprocesing pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
D) identified missing modules: atlas autocalibration for EM Segmentation scene, Island removal for ICC mask&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- Review currently deployed modules. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: reviewed firts seven subjects' outputs, added volume orientation module into pipeline (prevents ICBM atlas linear registration failures)&amp;lt;br&amp;gt;&lt;br /&gt;
- Fused ICC(brainmask) extraction module with EM Segmenter preprocessing. Three scenarious implemented: start with pre-extracted ICC mask (longitudinal studies case), run with ICC ectration, run with ICC extraction AND ICC correction before ICBM atlas preporcessing. &amp;lt;br&amp;gt;&lt;br /&gt;
- Completion of Human activities GUI (QC, ICC Correction) planned for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: Volume Orientation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: automated preprocessing pipeline for Slicer2 EM Segmenter test version deployed. Seven cases pre-processed.&lt;br /&gt;
- PET Quantitative measurements: Preliminary design specs discussion.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: BSplineRegistration (for non-linear registration), ResampleVolume2 (for atlases resampling based on image atlase templates registration). Local and Network runs are implemented, Cluster/GridWizard implementation pending.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Slicer EM Segmenter module: preprocessing design for Slicer2 EM Segmenter&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Adapting for Slicer2 EM Segmenter (mostly from pipelines and services for previous projects)&lt;br /&gt;
  -- Integration with FreeSurfer modules for bisafield correction, brainmask extraction, and linear registration of ICBM atlases&lt;br /&gt;
  -- Preprocessing updates for non-linear registration of ICBM atlases with Slicer2 (image re-orientation service designed)&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 29, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- EM Segmentaton pipeline: preprocessing results are being transferred to XNat (anonymized data, Central XNat) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Slicer EM Segmenter module: discussed agenda and scheduled a work meeting for Social Cognition Study image segmentation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Testing stage, 95% completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- SPL XNat server: verified data exchange via RESTfull web services.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 22, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Follow up with White Matter Lesion Segmenter and Scull Stripping Modules developers: Work in Progress&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Work in Progress, 60%+ completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Discussed SPINE image repository migration to XNat&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 15, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. &lt;br /&gt;
- Social Cognition Study: &lt;br /&gt;
Work-in-progress on intermediate (reconstruction) and results (resources) data storage at XNat.&lt;br /&gt;
&amp;lt;br&amp;gt;Reviewing and preparation more cases for EM Segmentor (Slicer 3.5) tuning.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* NA-MIC Project Week&lt;br /&gt;
Selecting candidate Slicer modules for other than Lesion EM Segmentation topics of Social Cognition study: Withe Matter Lesion Segmenter (UNC), Scull Stripping utility from UIOWA.&lt;br /&gt;
Reviewing issues of currently used Scull Stripping Slicer Extension and Slicer 3.5 EM Segmenter.&lt;br /&gt;
&amp;lt;br&amp;gt;XNat Data organizing training&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 1, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Preparation of Demo for NA-MIC work week: &lt;br /&gt;
- COPD Study. Added Remote pipepline start interface (represents real world scenario where Xnat repository, Processing modules and User are at different sites)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
- EM Segmentation. Added human activities steps to the workflow: ICC (brainmask) correction and EM Segmantation scena load per se.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 25, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Pilot workflow pipeline for EM Segmentation (all steps except user-activity step: ICC correction assignment and tracking)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 18, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Build and tested web services for EM Segmentation image preprocessing: DICOM-to-NRRD conversion, registration, skull stripping, image masking.&lt;br /&gt;
Started building workflow pipeline (subject to finish first version next week)&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Started Collecting Library of Slicer Build number vs. functional modules and extensions.&lt;br /&gt;
Plan for NAMIC project week: scheduled meetings for XNat data customization, Skull-stripping modules tuning, identified Social Cognition study cases that fail EM Segmentation processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 11, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Updating and verification of EM Segmentation Scenario&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Projects:ARRA:SlicerWF:UseCaseScenarios#Usecase_MS_lesion_Assessment&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Familiarizing with Slicer3.4/5 Modules required for implementation of EM Segmentation Scenario. Participation in debugging and/or usage tuning of Dicom Conversion, Registration, Skull Stripping, Masking, and Image Casting modules. &lt;br /&gt;
&lt;br /&gt;
* December 4, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Slicer3.4's EM Segmentation and Visual QC as part of image processing pipeline for Social Cognition Study for MS Patients.&lt;br /&gt;
Project emerged. EM Segmentation template creation debugged.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
Emphysema Measurements (COPD Study) - workflow stability and scalability test.&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 27, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Emphysema Measurements (COPD Study).&lt;br /&gt;
Added compensation for long running calculations and time-outs to the main computing pipeline.&lt;br /&gt;
Visual QC (work in progress)&lt;br /&gt;
** Infrastructure&lt;br /&gt;
XNat data structure customization, metadata storage, results consolidation: new feature request list creation (work in progress)&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 13, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
*** Pilot system for whole processing cycle for Emphysema Measurements (COPD Study) including the following:&lt;br /&gt;
Web query for CT session file list download&lt;br /&gt;
Pilot user interface for submitting the file list and starting processing pipeline&lt;br /&gt;
Notification about processing steps and failures&lt;br /&gt;
Upload results to XNat repository (at this stage results are uploaded into same folder where original scans are(*))&lt;br /&gt;
*** Immediate Plans&lt;br /&gt;
Complete Visual QC module&lt;br /&gt;
Design and implement meta-data transfer to XNat (including processing details and MRML files for loading images into the 3D Slicer)&lt;br /&gt;
&lt;br /&gt;
(*)Customization of results storage&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 6, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Tuned and debugged multiple subjects processing for: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat.&lt;br /&gt;
***Started working on quality control embedding into the above scenario. Plan to complete and video-record demo next week.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***Published general Product Integration scenario flow chart to collaborators' community. Discussion is open and in progress&lt;br /&gt;
&lt;br /&gt;
* October 30, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Piloted and tested the sequence: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat(1).&lt;br /&gt;
***Performance test of overall cycle: data transfer from remote serve is a bottleneck as expected&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data browsing features reviewed.&lt;br /&gt;
(1) Not automated yet&lt;br /&gt;
* October 23, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Defined COPD processing scenario with interoperability between Xnat, 3D Slicer Command Modules, Workflow, and Gridwizard Enterprise.&lt;br /&gt;
***Pilot version of Emphysema Measurements workflow pipeline deployed.&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data transfer features reviewed. Use account at XNat Central during learning curve.&lt;br /&gt;
***Feasibility test of 3D Slicer fiducials module for ROI highlights during QC and manual image processing activities. &lt;br /&gt;
* October 16, 2009&lt;br /&gt;
**Lung CT Scans Processing. Pilot project emerged. GenerateEmphysemaMeasurements module deployed as a webservice that submits jobs to computational cluster.&lt;br /&gt;
**EM Segmentation. Familiarized with GUI steps. Started working on automation steps outlining&lt;br /&gt;
**3D Slicer and XNat interaction. Got an overview from Wendy Plesniak.&lt;br /&gt;
* October 1 - 7, 2009&lt;br /&gt;
**Selected two first priority Projects: EM Segmentation of brain MRI images; Lung CT Scans Processing (COPD Study)&lt;br /&gt;
**Got initial outline of user requirements and design specs&lt;/div&gt;</summary>
		<author><name>Azaitsev</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=2011_Summer_Project_Week&amp;diff=67395</id>
		<title>2011 Summer Project Week</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=2011_Summer_Project_Week&amp;diff=67395"/>
		<updated>2011-05-31T18:42:39Z</updated>

		<summary type="html">&lt;p&gt;Azaitsev: /* Projects */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;  Back to [[Events]]&lt;br /&gt;
&lt;br /&gt;
[[image:PW-MIT2011.png|right|200px]]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
*'''Dates:''' June 20-24, 2011&lt;br /&gt;
*'''Location:''' MIT&lt;br /&gt;
&lt;br /&gt;
==Preliminary Agenda==&lt;br /&gt;
==Agenda==&lt;br /&gt;
&lt;br /&gt;
{|border=&amp;quot;1&amp;quot;&lt;br /&gt;
|-style=&amp;quot;background: #b0d5e6; color: #02186f; font-size: 130%&amp;quot; &lt;br /&gt;
!Time&lt;br /&gt;
!width=&amp;quot;250px&amp;quot;|Monday, June 20&lt;br /&gt;
!width=&amp;quot;250px&amp;quot;|Tuesday, June 21&lt;br /&gt;
!width=&amp;quot;250px&amp;quot;|Wednesday, June 22&lt;br /&gt;
!width=&amp;quot;250px&amp;quot;|Thursday, June 23&lt;br /&gt;
!width=&amp;quot;250px&amp;quot;|Friday, June 24&lt;br /&gt;
|-&lt;br /&gt;
|&lt;br /&gt;
|bgcolor=&amp;quot;#dbdbdb&amp;quot;|'''Project Presentations'''&lt;br /&gt;
|bgcolor=&amp;quot;#6494ec&amp;quot;|'''NA-MIC Update Day'''&lt;br /&gt;
|&lt;br /&gt;
|bgcolor=&amp;quot;#88aaae&amp;quot;|'''IGT Day'''&lt;br /&gt;
|bgcolor=&amp;quot;#faedb6&amp;quot;|'''Reporting Day'''&lt;br /&gt;
|-&lt;br /&gt;
|bgcolor=&amp;quot;#ffffdd&amp;quot;|'''8:30am'''&lt;br /&gt;
|&lt;br /&gt;
|bgcolor=&amp;quot;#ffffaa&amp;quot;|Breakfast&lt;br /&gt;
|bgcolor=&amp;quot;#ffffaa&amp;quot;|Breakfast&lt;br /&gt;
|bgcolor=&amp;quot;#ffffaa&amp;quot;|Breakfast&lt;br /&gt;
|bgcolor=&amp;quot;#ffffaa&amp;quot;|Breakfast&lt;br /&gt;
|-&lt;br /&gt;
|bgcolor=&amp;quot;#ffffdd&amp;quot;|'''9am-12pm'''&lt;br /&gt;
|&lt;br /&gt;
|'''9am-11am:''' [[2011 Project Week Breakout Session: Slicer4|Slicer 4 Core Modules Usability Review]]''' [[MIT_Project_Week_Rooms#Star|Star Room]]&lt;br /&gt;
&amp;lt;br&amp;gt;----------------------------------------&amp;lt;br&amp;gt;&lt;br /&gt;
'''11-12pm: &amp;lt;font color=&amp;quot;#4020ff&amp;quot;&amp;gt;Breakout Session:'''&amp;lt;/font&amp;gt; [[2011 Summer Project Week Breakout Session Slicer4 Annotation|Slicer4 Annotations]] (Nicole Aucoin)&amp;lt;br&amp;gt;&lt;br /&gt;
[[MIT_Project_Week_Rooms#Star|Star Room]]&lt;br /&gt;
|'''9am-12pm: &amp;lt;font color=&amp;quot;#4020ff&amp;quot;&amp;gt;Breakout Session:'''&amp;lt;/font&amp;gt;&amp;lt;br&amp;gt; [[2011 Project Week Breakout Session: ITK|ITK]] (Luis Ibanez)&lt;br /&gt;
&amp;lt;br&amp;gt;[[MIT_Project_Week_Rooms#Grier_34-401_AB|Star Room]]&lt;br /&gt;
|'''9am-5pm: &amp;lt;font color=&amp;quot;#4020ff&amp;quot;&amp;gt;Breakout Session:'''&amp;lt;/font&amp;gt;&amp;lt;br&amp;gt; [[2011 Summer Project Week Breakout Session:OpenIGTLink|OpenIGTLink]]&lt;br /&gt;
&amp;lt;br&amp;gt;[[MIT_Project_Week_Rooms#Grier_34-401_AB|Grier Rooms]]&lt;br /&gt;
|'''10am-12pm:''' [[#Projects|Project Progress Updates]]&lt;br /&gt;
&amp;lt;br&amp;gt;[[MIT_Project_Week_Rooms#Grier_34-401_AB|Grier Rooms]]&lt;br /&gt;
|-&lt;br /&gt;
|bgcolor=&amp;quot;#ffffdd&amp;quot;|'''12pm-1pm'''&lt;br /&gt;
|bgcolor=&amp;quot;#ffffaa&amp;quot;|Lunch&lt;br /&gt;
|bgcolor=&amp;quot;#ffffaa&amp;quot;|Lunch&lt;br /&gt;
|bgcolor=&amp;quot;#ffffaa&amp;quot;|Lunch&lt;br /&gt;
|bgcolor=&amp;quot;#ffffaa&amp;quot;|Lunch&lt;br /&gt;
|bgcolor=&amp;quot;#ffffaa&amp;quot;|Lunch boxes; Adjourn by 1:30pm&lt;br /&gt;
|-&lt;br /&gt;
|bgcolor=&amp;quot;#ffffdd&amp;quot;|'''1pm-5:30pm'''&lt;br /&gt;
|'''1-1:05pm: &amp;lt;font color=&amp;quot;#503020&amp;quot;&amp;gt;Ron Kikinis: Welcome&amp;lt;/font&amp;gt;'''&lt;br /&gt;
[[MIT_Project_Week_Rooms#Grier_34-401_AB|Grier Rooms]]&lt;br /&gt;
&amp;lt;br&amp;gt;----------------------------------------&amp;lt;br&amp;gt;&lt;br /&gt;
'''1:05-3:30pm:''' [[#Projects|Project Introductions]] (all Project Leads)&lt;br /&gt;
&amp;lt;br&amp;gt;[[MIT_Project_Week_Rooms#Grier_34-401_AB|Grier Rooms]]&lt;br /&gt;
&amp;lt;br&amp;gt;----------------------------------------&amp;lt;br&amp;gt;&lt;br /&gt;
'''3:30-5:00pm: NA-MIC Kit Update''' (Aylward, Miller, Pieper)&lt;br /&gt;
&amp;lt;br&amp;gt;[[MIT_Project_Week_Rooms#Grier_34-401_AB|Grier Rooms]]&lt;br /&gt;
|'''1-3pm: &amp;lt;font color=&amp;quot;#4020ff&amp;quot;&amp;gt;Breakout Session:'''&amp;lt;/font&amp;gt;&amp;lt;br&amp;gt; [http://wiki.slicer.org/slicerWiki/index.php/Slicer4:MultiVolumeContainer#Summer_2011_Project_Week_Breakout_Session Slicer4 MultiVolume Containers] (Nicole Aucoin)&lt;br /&gt;
&amp;lt;br&amp;gt;[[MIT_Project_Week_Rooms#Grier_34-401_AB|Star Room]]&lt;br /&gt;
&amp;lt;br&amp;gt;----------------------------------------&amp;lt;br&amp;gt;&lt;br /&gt;
'''3-4pm:''' [[Summer_2011_Tutorial_Contest|Tutorial Contest Presentations]]&lt;br /&gt;
&amp;lt;br&amp;gt;[[MIT_Project_Week_Rooms#Grier_34-401_AB|Grier Rooms]]&lt;br /&gt;
&amp;lt;br&amp;gt;----------------------------------------&amp;lt;br&amp;gt;&lt;br /&gt;
'''4-5pm:''' [[2011 Summer Project Week Breakout Session VTKCharts|VTK Charts]] (Marcus Hanwell)&lt;br /&gt;
&amp;lt;br&amp;gt;[[MIT_Project_Week_Rooms#32-D407|32-D407]]&lt;br /&gt;
&amp;lt;br&amp;gt;----------------------------------------&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;[[MIT_Project_Week_Rooms#Grier_34-401_AB|Star Room]]&lt;br /&gt;
|'''12:45-1pm:''' [[Events:TutorialContestJune2011|Tutorial Contest Winner Announcement]]&lt;br /&gt;
&amp;lt;br&amp;gt;[[MIT_Project_Week_Rooms#Grier_34-401_AB|Grier Rooms]]&lt;br /&gt;
&amp;lt;br&amp;gt;----------------------------------------&amp;lt;br&amp;gt;&lt;br /&gt;
'''3-4pm: &amp;lt;font color=&amp;quot;#4020ff&amp;quot;&amp;gt;Breakout Session:'''&amp;lt;/font&amp;gt;&amp;lt;br&amp;gt;Inter-subject Registration for EM segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;[[MIT_Project_Week_Rooms#Grier_34-401_AB|Star Room]]&lt;br /&gt;
&amp;lt;br&amp;gt;----------------------------------------&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;'''5pm: &amp;lt;font color=&amp;quot;#4020ff&amp;quot;&amp;gt;Reception'''&amp;lt;/font&amp;gt;&amp;lt;br&amp;gt; &lt;br /&gt;
&amp;lt;br&amp;gt;[[MIT_Project_Week_Rooms#R&amp;amp;D Pub|R&amp;amp;D Pub]]&lt;br /&gt;
|'''1-2pm: &amp;lt;font color=&amp;quot;#4020ff&amp;quot;&amp;gt;Breakout Session:'''&amp;lt;/font&amp;gt;&amp;lt;br&amp;gt; TBD&lt;br /&gt;
&amp;lt;br&amp;gt;----------------------------------------&amp;lt;br&amp;gt;&lt;br /&gt;
'''2-3pm:'''Breakout Session:TBD'''&lt;br /&gt;
&amp;lt;br&amp;gt;----------------------------------------&amp;lt;br&amp;gt;&lt;br /&gt;
'''3-4pm: &amp;lt;font color=&amp;quot;#4020ff&amp;quot;&amp;gt;Breakout Session: TBD'''&amp;lt;/font&amp;gt;&amp;lt;br&amp;gt; &lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|bgcolor=&amp;quot;#ffffdd&amp;quot;|'''5:30pm'''&lt;br /&gt;
|bgcolor=&amp;quot;#f0e68b&amp;quot;|Adjourn for the day&lt;br /&gt;
|bgcolor=&amp;quot;#f0e68b&amp;quot;|Adjourn for the day&lt;br /&gt;
|bgcolor=&amp;quot;#f0e68b&amp;quot;|Adjourn for the day&lt;br /&gt;
|bgcolor=&amp;quot;#f0e68b&amp;quot;|Adjourn for the day&lt;br /&gt;
|&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
==Projects==&lt;br /&gt;
#valuate the applicability of DICOM RT I/O facility in Slicer (via Plastimatch Extension) for Brachytherapy Planning (Tina Kapur, Greg Sharp, Robert Cormack?)&lt;br /&gt;
#Visualization of b-spline and vector fields (Steve, Danielle, Dominik)&lt;br /&gt;
#Annotation Module in Slicer4 (Nicole Aucoin, Daniel Haehn)&lt;br /&gt;
#Slicer4 Multivolume Containers (Ron Kikinis, Nicole Aucoin, Steve Pieper, ... )&lt;br /&gt;
#RECIST Slicer4 module (Nicole Aucoin)&lt;br /&gt;
#DicomToNrrdConverter refactoring ( Xiaodong Tao, Mark Scully)&lt;br /&gt;
#UNC Antialiasing Software as a Slicer extension or ITK module (Steve Pizer, Brad Davis, Petter Risholm, Andriy Fedorov)&lt;br /&gt;
# Normal consistency in particle correspondence computation using great circles in principal spheres - Huntington's Disease (Beatriz Paniagua, Martin Styner, Sungkyu Jung, Marc Scully)&lt;br /&gt;
# Group-wise Automatic Mesh-Based analysis of CortIcal Thickness (GAMBIT) - TBI (Clement Vachet, Martin Styner, Randi Gollub?)&lt;br /&gt;
#DTIProcessing - Huntington's Disease (Clement Vachet, Joy Matsui, Martin Styner)&lt;br /&gt;
#[[2011_Summer_Project__Week_Shape_Analysis_UNC |SPHARM &amp;amp; particles shape analysis - Huntington's Disease]] - Lucile Bompard, Clement Vachet, Mark Scully, Beatriz Paniagua, Martin Styner&lt;br /&gt;
# Non-rigid, inter-patient registration of bone masks derived from CT for Head and Neck Cancer Radiation Therapy (Ivan Kolesov, Yi Gao, Gregory Sharp, and Allen Tannenbaum)&lt;br /&gt;
# Robust Statiistical Segmentation (RSS) for the Atrial Fibrillation Ablation Therapy (Yi Gao, Kedar R, Wassim Haddad, and Allen Tannenbaum, Rob MacLeod, Josh Blauer, and Josh Cates)&lt;br /&gt;
#Mass Spectrometry for Brain Tumor Therapy (Behnood Gholami, Nathalie Agar)&lt;br /&gt;
#Multimodality Image Registration for TBI? (Yifei Lou, Danielle Pace, Jack Van Horn?, Marcel Prastawa?)&lt;br /&gt;
# DTIPrep - &amp;quot;Study-specific Protocol&amp;quot; based automatic DWI/DTI quality control and preparation - Huntington's Disease (Mashid Farzinfar, Clement Vachet, Joy Matsui, Martin Styner)&lt;br /&gt;
# Segmentation of Longitudinal TBI data (Bo Wang, Jack Van Horn, Andrei Irimia, Marcel Prastawa, Guido Gerig)&lt;br /&gt;
# Longitudinal Shape Regression - Huntington's Disease (James Fishbaugh, Guido Gerig)&lt;br /&gt;
# Dose volume histograms in Slicer (Greg Sharp, Nadya Shusharina, Steve Pieper, Csaba Pinter, Tina Kapur)&lt;br /&gt;
#Synthetic images, vector fields, RT structures and RT doses in Slicer and ITK. (Nadya Shusharina, Greg Sharp, Luis Ibanez, Steve Pieper)&lt;br /&gt;
# Interactive Watersheds Segmentation Module for Slicer  for Atrial Fibrillation and HN Cancer (Josh Cates, Ross Whitaker, Steve Pieper, Jim Miller, Nadya)&lt;br /&gt;
# Segmentation of Nerve and Nerve Ganglia in the Spine (Adrian Dalca, Giovanna Danagoulian, Ron Kikinis, Ehud Schmidt, Polina Golland)&lt;br /&gt;
# Image Manifold Learning with Spectral Embedding and Laplacian Eigenmaps (Ramesh Sridharan, Polina Golland)&lt;br /&gt;
# Shapeworks Shape Analysis for Atrial Fibrilliation and HD (Manasi Datar, Beatriz UNC, Marc Scully)&lt;br /&gt;
# Volumetric DTI into Slicer for HD for Tract based roi segmentation (Steve Callahan, Marc Scully, Jim Miller)&lt;br /&gt;
#Explore the applicability of RSS and Shapeworks for Ventricular Segmentation(Chiara Carminati, ?, ?)&lt;br /&gt;
# Integrate BRAINSCut into Slicer3(Regina Kim, ... )&lt;br /&gt;
# The Vascular Modeling Toolkit in 3D Slicer 4 (Daniel Haehn, Luca Antiga, Steve Pieper)	&lt;br /&gt;
# Integration of LANDWARP into interactive registration module for MR-guided prostate biopsy (Andrey Fedorov, Greg Sharp, Nadya Shusharina)&lt;br /&gt;
# Registration of mouse brains (Francois Budin)&lt;br /&gt;
# ShapeWorks Applications (Manasi Datar, Beatriz Paniagua, Martin Styner, Ross Whitaker, ?)&lt;br /&gt;
# Wireless joystick controlling Slicer4 (Szymon Kostrzewski)&lt;br /&gt;
# Live Tracked Ultrasound in 3D Slicer 4 (Tamas Heffter)&lt;br /&gt;
# [http://wiki.na-mic.org/Wiki/index.php/Survey_stealthlink_openigtlink Surveying research teams interested in Open IGT Link support of Stealth Station (Nobuhiko Hata, Ron Kikinis)]&lt;br /&gt;
#Nifti Support for Diffusion Tensor Images&lt;br /&gt;
# Finishing details on the workflows: DICOM-&amp;gt;Full brain tractography / peritumoral (Demian)&lt;br /&gt;
# Refactoring of the tractography display widget (Isaiah)&lt;br /&gt;
# Laterality (Lauren)&lt;br /&gt;
# Selection for models and bundles post-clustering (Lauren)&lt;br /&gt;
#ROI-based / picking selection of fiber bundles (Maybe one of Sylvain's interns)&lt;br /&gt;
#Adding streamlined tractography to the Finsler front propagation tractography toolkit (Antonio)&lt;br /&gt;
#Add ODF estimation / visualization (Antonio)&lt;br /&gt;
# Workflows and Service Oriented Architecture Modules for Slicer4 as Extensions (Alexander Zaitsev, Wendy Plesniak, Ron Kikinis)&lt;br /&gt;
&lt;br /&gt;
==Background==&lt;br /&gt;
&lt;br /&gt;
We are pleased to announce the 13th PROJECT WEEK of hands-on research and development activity for applications in Image-Guided Therapy, Neuroscience, and several additional areas of biomedical research that enable personalized medicine. Participants will engage in open source programming using the [[NA-MIC-Kit|NA-MIC Kit]], algorithm design, medical imaging sequence development, tracking experiments, and clinical application. The main goal of this event is to move forward the translational research deliverables of the sponsoring centers and their collaborators. Active and potential collaborators are encouraged and welcome to attend this event. This event will be set up to maximize informal interaction between participants.  If you would like to learn more about this event, please [http://public.kitware.com/cgi-bin/mailman/listinfo/na-mic-project-week click here to join our mailing list].&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Active preparation begins on Thursday, April 28th at 3pm ET, with a kick-off teleconference.  Invitations to this call will be sent to members of the sponsoring communities, their collaborators, past attendees of the event, as well as any parties who have expressed an interest in working with these centers. The main goal of the kick-off call is to get an idea of which groups/projects will be active at the upcoming event, and to ensure that there is sufficient coverage for all. Subsequent teleconferences will allow for more focused discussions on individual projects and allow the hosts to finalize the project teams, consolidate any common components, and identify topics that should be discussed in breakout sessions. In the final days leading upto the meeting, all project teams will be asked to fill in a template page on this wiki that describes the objectives and plan of their projects.  &lt;br /&gt;
&lt;br /&gt;
The event itself will start off with a short presentation by each project team, driven using their previously created description, and will help all participants get acquainted with others who are doing similar work. In the rest of the week, about half the time will be spent in breakout discussions on topics of common interest of subsets of the attendees, and the other half will be spent in project teams, doing hands-on project work.  The hands-on activities will be done in 40-50 small teams of size 2-4, each with a mix of multi-disciplinary expertise.  To facilitate this work, a large room at MIT will be setup with several tables, with internet and power access, and each computer software development based team will gather on a table with their individual laptops, connect to the internet to download their software and data, and be able to work on their projects.  Teams working on projects that require the use of medical devices will proceed to Brigham and Women's Hospital and carry out their experiments there. On the last day of the event, a closing presentation session will be held in which each project team will present a summary of what they accomplished during the week.&lt;br /&gt;
&lt;br /&gt;
This event is part of the translational research efforts of [http://www.na-mic.org NA-MIC], [http://www.ncigt.org NCIGT], [http://nac.spl.harvard.edu/ NAC], [http://catalyst.harvard.edu/home.html Harvard Catalyst], and [http://www.cimit.org CIMIT].  It is an expansion of the NA-MIC Summer Project Week that has been held annually since 2005. It will be held every summer at MIT and Brigham and Womens Hospital in Boston, typically during the last full week of June, and in Salt Lake City in the winter, typically during the second week of January.  &lt;br /&gt;
&lt;br /&gt;
A summary of all past NA-MIC Project Events is available [[Project_Events#Past|here]].&lt;br /&gt;
&lt;br /&gt;
== Logistics ==&lt;br /&gt;
*'''Dates:''' June 20-24, 2011&lt;br /&gt;
*'''Location:''' MIT. [[Meeting_Locations:MIT_Grier_A_%26B|Grier Rooms A &amp;amp; B: 34-401A &amp;amp; 34-401B]].&lt;br /&gt;
*'''REGISTRATION:''' Please register [http://guest.cvent.com/d/sdqy0l/4W here].  Payment must be made by credit card.&lt;br /&gt;
*'''Registration Fee:''' $260 (covers the cost of breakfast, lunch and coffee breaks for the week). &lt;br /&gt;
*'''Hotel:''' Boston Marriott Cambridge, Two Cambridge Center, 50 Broadway, Cambridge, MA 02142.  Group rate is $199/night plus tax.  Book [http://www.marriott.com/hotels/travel/boscb?groupCode=jrbjrba&amp;amp;app=resvlink&amp;amp;fromDate=6/19/11&amp;amp;toDate=6/24/11 here] or call 1-617-494-6600 and mention that you are booking in the MIT Room Block.  '''All reservations must be made by May 29, 2011 to receive the discounted rate.'''&lt;br /&gt;
&lt;br /&gt;
== Preparation ==&lt;br /&gt;
&lt;br /&gt;
# Please make sure that you are on the http://public.kitware.com/cgi-bin/mailman/listinfo/na-mic-project-week mailing list&lt;br /&gt;
# The NA-MIC engineering team will be discussing infrastructure projects in a kickoff TCON on April 28, 3pm ET.  In the weeks following, new and old participants from the above mailing list will be invited to join to discuss their projects, so please make sure you are on it!&lt;br /&gt;
# By 3pm ET on Thursday May 12, all participants to add a one line title of their project to #Projects&lt;br /&gt;
#By 3pm ET on Thursday June 9, all project leads to complete [[Project_Week/Template|Complete a templated wiki page for your project]]. Please do not edit the template page itself, but create a new page for your project and cut-and-paste the text from this template page.  If you have questions, please send an email to tkapur at bwh.harvard.edu.&lt;br /&gt;
# By 3pm on June 16: Create a directory for each project on the [[Engineering:SandBox|NAMIC Sandbox]] (Zack)&lt;br /&gt;
## Commit on each sandbox directory the code examples/snippets that represent our first guesses of appropriate methods. (Luis and Steve will help with this, as needed)&lt;br /&gt;
## Gather test images in any of the Data sharing resources we have (e.g. XNAT/MIDAS). These ones don't have to be many. At least three different cases, so we can get an idea of the modality-specific characteristics of these images. Put the IDs of these data sets on the wiki page. (the participants must do this.)&lt;br /&gt;
## Setup nightly tests on a separate Dashboard, where we will run the methods that we are experimenting with. The test should post result images and computation time. (Zack)&lt;br /&gt;
# Please note that by the time we get to the project event, we should be trying to close off a project milestone rather than starting to work on one...&lt;br /&gt;
# People doing Slicer related projects should come to project week with slicer built on your laptop.&lt;br /&gt;
## Projects to develop extension modules should work with the [http://viewvc.slicer.org/viewcvs.cgi/branches/Slicer-3-6/#dirlist Slicer-3-6 branch] (new code should not be checked into the branch).&lt;br /&gt;
## Projects to modify core behavior of slicer should be done on the [http://viewvc.slicer.org/viewcvs.cgi/trunk/ trunk].&lt;/div&gt;</summary>
		<author><name>Azaitsev</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=2011_Summer_Project_Week&amp;diff=67394</id>
		<title>2011 Summer Project Week</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=2011_Summer_Project_Week&amp;diff=67394"/>
		<updated>2011-05-31T18:42:20Z</updated>

		<summary type="html">&lt;p&gt;Azaitsev: /* Projects */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;  Back to [[Events]]&lt;br /&gt;
&lt;br /&gt;
[[image:PW-MIT2011.png|right|200px]]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
*'''Dates:''' June 20-24, 2011&lt;br /&gt;
*'''Location:''' MIT&lt;br /&gt;
&lt;br /&gt;
==Preliminary Agenda==&lt;br /&gt;
==Agenda==&lt;br /&gt;
&lt;br /&gt;
{|border=&amp;quot;1&amp;quot;&lt;br /&gt;
|-style=&amp;quot;background: #b0d5e6; color: #02186f; font-size: 130%&amp;quot; &lt;br /&gt;
!Time&lt;br /&gt;
!width=&amp;quot;250px&amp;quot;|Monday, June 20&lt;br /&gt;
!width=&amp;quot;250px&amp;quot;|Tuesday, June 21&lt;br /&gt;
!width=&amp;quot;250px&amp;quot;|Wednesday, June 22&lt;br /&gt;
!width=&amp;quot;250px&amp;quot;|Thursday, June 23&lt;br /&gt;
!width=&amp;quot;250px&amp;quot;|Friday, June 24&lt;br /&gt;
|-&lt;br /&gt;
|&lt;br /&gt;
|bgcolor=&amp;quot;#dbdbdb&amp;quot;|'''Project Presentations'''&lt;br /&gt;
|bgcolor=&amp;quot;#6494ec&amp;quot;|'''NA-MIC Update Day'''&lt;br /&gt;
|&lt;br /&gt;
|bgcolor=&amp;quot;#88aaae&amp;quot;|'''IGT Day'''&lt;br /&gt;
|bgcolor=&amp;quot;#faedb6&amp;quot;|'''Reporting Day'''&lt;br /&gt;
|-&lt;br /&gt;
|bgcolor=&amp;quot;#ffffdd&amp;quot;|'''8:30am'''&lt;br /&gt;
|&lt;br /&gt;
|bgcolor=&amp;quot;#ffffaa&amp;quot;|Breakfast&lt;br /&gt;
|bgcolor=&amp;quot;#ffffaa&amp;quot;|Breakfast&lt;br /&gt;
|bgcolor=&amp;quot;#ffffaa&amp;quot;|Breakfast&lt;br /&gt;
|bgcolor=&amp;quot;#ffffaa&amp;quot;|Breakfast&lt;br /&gt;
|-&lt;br /&gt;
|bgcolor=&amp;quot;#ffffdd&amp;quot;|'''9am-12pm'''&lt;br /&gt;
|&lt;br /&gt;
|'''9am-11am:''' [[2011 Project Week Breakout Session: Slicer4|Slicer 4 Core Modules Usability Review]]''' [[MIT_Project_Week_Rooms#Star|Star Room]]&lt;br /&gt;
&amp;lt;br&amp;gt;----------------------------------------&amp;lt;br&amp;gt;&lt;br /&gt;
'''11-12pm: &amp;lt;font color=&amp;quot;#4020ff&amp;quot;&amp;gt;Breakout Session:'''&amp;lt;/font&amp;gt; [[2011 Summer Project Week Breakout Session Slicer4 Annotation|Slicer4 Annotations]] (Nicole Aucoin)&amp;lt;br&amp;gt;&lt;br /&gt;
[[MIT_Project_Week_Rooms#Star|Star Room]]&lt;br /&gt;
|'''9am-12pm: &amp;lt;font color=&amp;quot;#4020ff&amp;quot;&amp;gt;Breakout Session:'''&amp;lt;/font&amp;gt;&amp;lt;br&amp;gt; [[2011 Project Week Breakout Session: ITK|ITK]] (Luis Ibanez)&lt;br /&gt;
&amp;lt;br&amp;gt;[[MIT_Project_Week_Rooms#Grier_34-401_AB|Star Room]]&lt;br /&gt;
|'''9am-5pm: &amp;lt;font color=&amp;quot;#4020ff&amp;quot;&amp;gt;Breakout Session:'''&amp;lt;/font&amp;gt;&amp;lt;br&amp;gt; [[2011 Summer Project Week Breakout Session:OpenIGTLink|OpenIGTLink]]&lt;br /&gt;
&amp;lt;br&amp;gt;[[MIT_Project_Week_Rooms#Grier_34-401_AB|Grier Rooms]]&lt;br /&gt;
|'''10am-12pm:''' [[#Projects|Project Progress Updates]]&lt;br /&gt;
&amp;lt;br&amp;gt;[[MIT_Project_Week_Rooms#Grier_34-401_AB|Grier Rooms]]&lt;br /&gt;
|-&lt;br /&gt;
|bgcolor=&amp;quot;#ffffdd&amp;quot;|'''12pm-1pm'''&lt;br /&gt;
|bgcolor=&amp;quot;#ffffaa&amp;quot;|Lunch&lt;br /&gt;
|bgcolor=&amp;quot;#ffffaa&amp;quot;|Lunch&lt;br /&gt;
|bgcolor=&amp;quot;#ffffaa&amp;quot;|Lunch&lt;br /&gt;
|bgcolor=&amp;quot;#ffffaa&amp;quot;|Lunch&lt;br /&gt;
|bgcolor=&amp;quot;#ffffaa&amp;quot;|Lunch boxes; Adjourn by 1:30pm&lt;br /&gt;
|-&lt;br /&gt;
|bgcolor=&amp;quot;#ffffdd&amp;quot;|'''1pm-5:30pm'''&lt;br /&gt;
|'''1-1:05pm: &amp;lt;font color=&amp;quot;#503020&amp;quot;&amp;gt;Ron Kikinis: Welcome&amp;lt;/font&amp;gt;'''&lt;br /&gt;
[[MIT_Project_Week_Rooms#Grier_34-401_AB|Grier Rooms]]&lt;br /&gt;
&amp;lt;br&amp;gt;----------------------------------------&amp;lt;br&amp;gt;&lt;br /&gt;
'''1:05-3:30pm:''' [[#Projects|Project Introductions]] (all Project Leads)&lt;br /&gt;
&amp;lt;br&amp;gt;[[MIT_Project_Week_Rooms#Grier_34-401_AB|Grier Rooms]]&lt;br /&gt;
&amp;lt;br&amp;gt;----------------------------------------&amp;lt;br&amp;gt;&lt;br /&gt;
'''3:30-5:00pm: NA-MIC Kit Update''' (Aylward, Miller, Pieper)&lt;br /&gt;
&amp;lt;br&amp;gt;[[MIT_Project_Week_Rooms#Grier_34-401_AB|Grier Rooms]]&lt;br /&gt;
|'''1-3pm: &amp;lt;font color=&amp;quot;#4020ff&amp;quot;&amp;gt;Breakout Session:'''&amp;lt;/font&amp;gt;&amp;lt;br&amp;gt; [http://wiki.slicer.org/slicerWiki/index.php/Slicer4:MultiVolumeContainer#Summer_2011_Project_Week_Breakout_Session Slicer4 MultiVolume Containers] (Nicole Aucoin)&lt;br /&gt;
&amp;lt;br&amp;gt;[[MIT_Project_Week_Rooms#Grier_34-401_AB|Star Room]]&lt;br /&gt;
&amp;lt;br&amp;gt;----------------------------------------&amp;lt;br&amp;gt;&lt;br /&gt;
'''3-4pm:''' [[Summer_2011_Tutorial_Contest|Tutorial Contest Presentations]]&lt;br /&gt;
&amp;lt;br&amp;gt;[[MIT_Project_Week_Rooms#Grier_34-401_AB|Grier Rooms]]&lt;br /&gt;
&amp;lt;br&amp;gt;----------------------------------------&amp;lt;br&amp;gt;&lt;br /&gt;
'''4-5pm:''' [[2011 Summer Project Week Breakout Session VTKCharts|VTK Charts]] (Marcus Hanwell)&lt;br /&gt;
&amp;lt;br&amp;gt;[[MIT_Project_Week_Rooms#32-D407|32-D407]]&lt;br /&gt;
&amp;lt;br&amp;gt;----------------------------------------&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;[[MIT_Project_Week_Rooms#Grier_34-401_AB|Star Room]]&lt;br /&gt;
|'''12:45-1pm:''' [[Events:TutorialContestJune2011|Tutorial Contest Winner Announcement]]&lt;br /&gt;
&amp;lt;br&amp;gt;[[MIT_Project_Week_Rooms#Grier_34-401_AB|Grier Rooms]]&lt;br /&gt;
&amp;lt;br&amp;gt;----------------------------------------&amp;lt;br&amp;gt;&lt;br /&gt;
'''3-4pm: &amp;lt;font color=&amp;quot;#4020ff&amp;quot;&amp;gt;Breakout Session:'''&amp;lt;/font&amp;gt;&amp;lt;br&amp;gt;Inter-subject Registration for EM segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;[[MIT_Project_Week_Rooms#Grier_34-401_AB|Star Room]]&lt;br /&gt;
&amp;lt;br&amp;gt;----------------------------------------&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;'''5pm: &amp;lt;font color=&amp;quot;#4020ff&amp;quot;&amp;gt;Reception'''&amp;lt;/font&amp;gt;&amp;lt;br&amp;gt; &lt;br /&gt;
&amp;lt;br&amp;gt;[[MIT_Project_Week_Rooms#R&amp;amp;D Pub|R&amp;amp;D Pub]]&lt;br /&gt;
|'''1-2pm: &amp;lt;font color=&amp;quot;#4020ff&amp;quot;&amp;gt;Breakout Session:'''&amp;lt;/font&amp;gt;&amp;lt;br&amp;gt; TBD&lt;br /&gt;
&amp;lt;br&amp;gt;----------------------------------------&amp;lt;br&amp;gt;&lt;br /&gt;
'''2-3pm:'''Breakout Session:TBD'''&lt;br /&gt;
&amp;lt;br&amp;gt;----------------------------------------&amp;lt;br&amp;gt;&lt;br /&gt;
'''3-4pm: &amp;lt;font color=&amp;quot;#4020ff&amp;quot;&amp;gt;Breakout Session: TBD'''&amp;lt;/font&amp;gt;&amp;lt;br&amp;gt; &lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|bgcolor=&amp;quot;#ffffdd&amp;quot;|'''5:30pm'''&lt;br /&gt;
|bgcolor=&amp;quot;#f0e68b&amp;quot;|Adjourn for the day&lt;br /&gt;
|bgcolor=&amp;quot;#f0e68b&amp;quot;|Adjourn for the day&lt;br /&gt;
|bgcolor=&amp;quot;#f0e68b&amp;quot;|Adjourn for the day&lt;br /&gt;
|bgcolor=&amp;quot;#f0e68b&amp;quot;|Adjourn for the day&lt;br /&gt;
|&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
==Projects==&lt;br /&gt;
#valuate the applicability of DICOM RT I/O facility in Slicer (via Plastimatch Extension) for Brachytherapy Planning (Tina Kapur, Greg Sharp, Robert Cormack?)&lt;br /&gt;
#Visualization of b-spline and vector fields (Steve, Danielle, Dominik)&lt;br /&gt;
#Annotation Module in Slicer4 (Nicole Aucoin, Daniel Haehn)&lt;br /&gt;
#Slicer4 Multivolume Containers (Ron Kikinis, Nicole Aucoin, Steve Pieper, ... )&lt;br /&gt;
#RECIST Slicer4 module (Nicole Aucoin)&lt;br /&gt;
#DicomToNrrdConverter refactoring ( Xiaodong Tao, Mark Scully)&lt;br /&gt;
#UNC Antialiasing Software as a Slicer extension or ITK module (Steve Pizer, Brad Davis, Petter Risholm, Andriy Fedorov)&lt;br /&gt;
# Normal consistency in particle correspondence computation using great circles in principal spheres - Huntington's Disease (Beatriz Paniagua, Martin Styner, Sungkyu Jung, Marc Scully)&lt;br /&gt;
# Group-wise Automatic Mesh-Based analysis of CortIcal Thickness (GAMBIT) - TBI (Clement Vachet, Martin Styner, Randi Gollub?)&lt;br /&gt;
#DTIProcessing - Huntington's Disease (Clement Vachet, Joy Matsui, Martin Styner)&lt;br /&gt;
#[[2011_Summer_Project__Week_Shape_Analysis_UNC |SPHARM &amp;amp; particles shape analysis - Huntington's Disease]] - Lucile Bompard, Clement Vachet, Mark Scully, Beatriz Paniagua, Martin Styner&lt;br /&gt;
# Non-rigid, inter-patient registration of bone masks derived from CT for Head and Neck Cancer Radiation Therapy (Ivan Kolesov, Yi Gao, Gregory Sharp, and Allen Tannenbaum)&lt;br /&gt;
# Robust Statiistical Segmentation (RSS) for the Atrial Fibrillation Ablation Therapy (Yi Gao, Kedar R, Wassim Haddad, and Allen Tannenbaum, Rob MacLeod, Josh Blauer, and Josh Cates)&lt;br /&gt;
#Mass Spectrometry for Brain Tumor Therapy (Behnood Gholami, Nathalie Agar)&lt;br /&gt;
#Multimodality Image Registration for TBI? (Yifei Lou, Danielle Pace, Jack Van Horn?, Marcel Prastawa?)&lt;br /&gt;
# DTIPrep - &amp;quot;Study-specific Protocol&amp;quot; based automatic DWI/DTI quality control and preparation - Huntington's Disease (Mashid Farzinfar, Clement Vachet, Joy Matsui, Martin Styner)&lt;br /&gt;
# Segmentation of Longitudinal TBI data (Bo Wang, Jack Van Horn, Andrei Irimia, Marcel Prastawa, Guido Gerig)&lt;br /&gt;
# Longitudinal Shape Regression - Huntington's Disease (James Fishbaugh, Guido Gerig)&lt;br /&gt;
# Dose volume histograms in Slicer (Greg Sharp, Nadya Shusharina, Steve Pieper, Csaba Pinter, Tina Kapur)&lt;br /&gt;
#Synthetic images, vector fields, RT structures and RT doses in Slicer and ITK. (Nadya Shusharina, Greg Sharp, Luis Ibanez, Steve Pieper)&lt;br /&gt;
# Interactive Watersheds Segmentation Module for Slicer  for Atrial Fibrillation and HN Cancer (Josh Cates, Ross Whitaker, Steve Pieper, Jim Miller, Nadya)&lt;br /&gt;
# Segmentation of Nerve and Nerve Ganglia in the Spine (Adrian Dalca, Giovanna Danagoulian, Ron Kikinis, Ehud Schmidt, Polina Golland)&lt;br /&gt;
# Image Manifold Learning with Spectral Embedding and Laplacian Eigenmaps (Ramesh Sridharan, Polina Golland)&lt;br /&gt;
# Shapeworks Shape Analysis for Atrial Fibrilliation and HD (Manasi Datar, Beatriz UNC, Marc Scully)&lt;br /&gt;
# Volumetric DTI into Slicer for HD for Tract based roi segmentation (Steve Callahan, Marc Scully, Jim Miller)&lt;br /&gt;
#Explore the applicability of RSS and Shapeworks for Ventricular Segmentation(Chiara Carminati, ?, ?)&lt;br /&gt;
# Integrate BRAINSCut into Slicer3(Regina Kim, ... )&lt;br /&gt;
# The Vascular Modeling Toolkit in 3D Slicer 4 (Daniel Haehn, Luca Antiga, Steve Pieper)	&lt;br /&gt;
# Integration of LANDWARP into interactive registration module for MR-guided prostate biopsy (Andrey Fedorov, Greg Sharp, Nadya Shusharina)&lt;br /&gt;
# Registration of mouse brains (Francois Budin)&lt;br /&gt;
# ShapeWorks Applications (Manasi Datar, Beatriz Paniagua, Martin Styner, Ross Whitaker, ?)&lt;br /&gt;
# Wireless joystick controlling Slicer4 (Szymon Kostrzewski)&lt;br /&gt;
# Live Tracked Ultrasound in 3D Slicer 4 (Tamas Heffter)&lt;br /&gt;
# [http://wiki.na-mic.org/Wiki/index.php/Survey_stealthlink_openigtlink Surveying research teams interested in Open IGT Link support of Stealth Station (Nobuhiko Hata, Ron Kikinis)]&lt;br /&gt;
#Nifti Support for Diffusion Tensor Images&lt;br /&gt;
# Finishing details on the workflows: DICOM-&amp;gt;Full brain tractography / peritumoral (Demian)&lt;br /&gt;
# Refactoring of the tractography display widget (Isaiah)&lt;br /&gt;
# Laterality (Lauren)&lt;br /&gt;
# Selection for models and bundles post-clustering (Lauren)&lt;br /&gt;
#ROI-based / picking selection of fiber bundles (Maybe one of Sylvain's interns)&lt;br /&gt;
#Adding streamlined tractography to the Finsler front propagation tractography toolkit (Antonio)&lt;br /&gt;
#Add ODF estimation / visualization (Antonio)&lt;br /&gt;
# Workflows and Service Oriented Architecture Modules for Slicer4 as Extensions (Alexander Zaitsev, Wendy Plesniak, Charles Guttmann, Ron Kikinis)&lt;br /&gt;
&lt;br /&gt;
==Background==&lt;br /&gt;
&lt;br /&gt;
We are pleased to announce the 13th PROJECT WEEK of hands-on research and development activity for applications in Image-Guided Therapy, Neuroscience, and several additional areas of biomedical research that enable personalized medicine. Participants will engage in open source programming using the [[NA-MIC-Kit|NA-MIC Kit]], algorithm design, medical imaging sequence development, tracking experiments, and clinical application. The main goal of this event is to move forward the translational research deliverables of the sponsoring centers and their collaborators. Active and potential collaborators are encouraged and welcome to attend this event. This event will be set up to maximize informal interaction between participants.  If you would like to learn more about this event, please [http://public.kitware.com/cgi-bin/mailman/listinfo/na-mic-project-week click here to join our mailing list].&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Active preparation begins on Thursday, April 28th at 3pm ET, with a kick-off teleconference.  Invitations to this call will be sent to members of the sponsoring communities, their collaborators, past attendees of the event, as well as any parties who have expressed an interest in working with these centers. The main goal of the kick-off call is to get an idea of which groups/projects will be active at the upcoming event, and to ensure that there is sufficient coverage for all. Subsequent teleconferences will allow for more focused discussions on individual projects and allow the hosts to finalize the project teams, consolidate any common components, and identify topics that should be discussed in breakout sessions. In the final days leading upto the meeting, all project teams will be asked to fill in a template page on this wiki that describes the objectives and plan of their projects.  &lt;br /&gt;
&lt;br /&gt;
The event itself will start off with a short presentation by each project team, driven using their previously created description, and will help all participants get acquainted with others who are doing similar work. In the rest of the week, about half the time will be spent in breakout discussions on topics of common interest of subsets of the attendees, and the other half will be spent in project teams, doing hands-on project work.  The hands-on activities will be done in 40-50 small teams of size 2-4, each with a mix of multi-disciplinary expertise.  To facilitate this work, a large room at MIT will be setup with several tables, with internet and power access, and each computer software development based team will gather on a table with their individual laptops, connect to the internet to download their software and data, and be able to work on their projects.  Teams working on projects that require the use of medical devices will proceed to Brigham and Women's Hospital and carry out their experiments there. On the last day of the event, a closing presentation session will be held in which each project team will present a summary of what they accomplished during the week.&lt;br /&gt;
&lt;br /&gt;
This event is part of the translational research efforts of [http://www.na-mic.org NA-MIC], [http://www.ncigt.org NCIGT], [http://nac.spl.harvard.edu/ NAC], [http://catalyst.harvard.edu/home.html Harvard Catalyst], and [http://www.cimit.org CIMIT].  It is an expansion of the NA-MIC Summer Project Week that has been held annually since 2005. It will be held every summer at MIT and Brigham and Womens Hospital in Boston, typically during the last full week of June, and in Salt Lake City in the winter, typically during the second week of January.  &lt;br /&gt;
&lt;br /&gt;
A summary of all past NA-MIC Project Events is available [[Project_Events#Past|here]].&lt;br /&gt;
&lt;br /&gt;
== Logistics ==&lt;br /&gt;
*'''Dates:''' June 20-24, 2011&lt;br /&gt;
*'''Location:''' MIT. [[Meeting_Locations:MIT_Grier_A_%26B|Grier Rooms A &amp;amp; B: 34-401A &amp;amp; 34-401B]].&lt;br /&gt;
*'''REGISTRATION:''' Please register [http://guest.cvent.com/d/sdqy0l/4W here].  Payment must be made by credit card.&lt;br /&gt;
*'''Registration Fee:''' $260 (covers the cost of breakfast, lunch and coffee breaks for the week). &lt;br /&gt;
*'''Hotel:''' Boston Marriott Cambridge, Two Cambridge Center, 50 Broadway, Cambridge, MA 02142.  Group rate is $199/night plus tax.  Book [http://www.marriott.com/hotels/travel/boscb?groupCode=jrbjrba&amp;amp;app=resvlink&amp;amp;fromDate=6/19/11&amp;amp;toDate=6/24/11 here] or call 1-617-494-6600 and mention that you are booking in the MIT Room Block.  '''All reservations must be made by May 29, 2011 to receive the discounted rate.'''&lt;br /&gt;
&lt;br /&gt;
== Preparation ==&lt;br /&gt;
&lt;br /&gt;
# Please make sure that you are on the http://public.kitware.com/cgi-bin/mailman/listinfo/na-mic-project-week mailing list&lt;br /&gt;
# The NA-MIC engineering team will be discussing infrastructure projects in a kickoff TCON on April 28, 3pm ET.  In the weeks following, new and old participants from the above mailing list will be invited to join to discuss their projects, so please make sure you are on it!&lt;br /&gt;
# By 3pm ET on Thursday May 12, all participants to add a one line title of their project to #Projects&lt;br /&gt;
#By 3pm ET on Thursday June 9, all project leads to complete [[Project_Week/Template|Complete a templated wiki page for your project]]. Please do not edit the template page itself, but create a new page for your project and cut-and-paste the text from this template page.  If you have questions, please send an email to tkapur at bwh.harvard.edu.&lt;br /&gt;
# By 3pm on June 16: Create a directory for each project on the [[Engineering:SandBox|NAMIC Sandbox]] (Zack)&lt;br /&gt;
## Commit on each sandbox directory the code examples/snippets that represent our first guesses of appropriate methods. (Luis and Steve will help with this, as needed)&lt;br /&gt;
## Gather test images in any of the Data sharing resources we have (e.g. XNAT/MIDAS). These ones don't have to be many. At least three different cases, so we can get an idea of the modality-specific characteristics of these images. Put the IDs of these data sets on the wiki page. (the participants must do this.)&lt;br /&gt;
## Setup nightly tests on a separate Dashboard, where we will run the methods that we are experimenting with. The test should post result images and computation time. (Zack)&lt;br /&gt;
# Please note that by the time we get to the project event, we should be trying to close off a project milestone rather than starting to work on one...&lt;br /&gt;
# People doing Slicer related projects should come to project week with slicer built on your laptop.&lt;br /&gt;
## Projects to develop extension modules should work with the [http://viewvc.slicer.org/viewcvs.cgi/branches/Slicer-3-6/#dirlist Slicer-3-6 branch] (new code should not be checked into the branch).&lt;br /&gt;
## Projects to modify core behavior of slicer should be done on the [http://viewvc.slicer.org/viewcvs.cgi/trunk/ trunk].&lt;/div&gt;</summary>
		<author><name>Azaitsev</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=67390</id>
		<title>Projects:ARRA:SlicerWF</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=67390"/>
		<updated>2011-05-31T13:40:31Z</updated>

		<summary type="html">&lt;p&gt;Azaitsev: /* Progress */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Projects:ARRASuplements|Back to Slicer ARRA home page]]&lt;br /&gt;
= Aim =&lt;br /&gt;
Supplement 3D Slicer and Extensible Neuroimaging Archive Toolkit (XNAT) with workflow management system. Provide integration and interoperability between 3D Slicer, XNAT Services and 3-rd party image processing applications and high performance computing systems. Implement it as within currently developed Structural Planning and Implementation in Neurological Exploration (SPINE) System.&lt;br /&gt;
&lt;br /&gt;
= SPINE Project Documentation =&lt;br /&gt;
[http://cni.bwh.harvard.edu/projects/spine/index.html SPINE Docs]&lt;br /&gt;
&lt;br /&gt;
= Presentations =&lt;br /&gt;
* Segmentation Workflow. PECS University Social Cognition Study.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:SlicerWF_NAC_PECS_Workflow.pdf]]&lt;br /&gt;
* EAB10_ARRA Annual Progress Report Slides.&amp;lt;br&amp;gt;&lt;br /&gt;
[[media:EAB10_ARRA_WF_2011_Zaitsev.ppt | Service Oriented Solutions for 3D Slicer. EAB10_ARRA_WF_2011. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:EAB10_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:NAMIC_ARRA_WF_2011_Zaitsev.ppt  | NAMIC Annual Report 04/2010-03/2011. NAMIC_ARRA_WF_2011_Zaitsev. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:NAMIC_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:Slicer_WF_Slicer4CARMAWorkflow.ppt  | CARMA Workflow. Cardiac Ablation Followup. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:Slicer_WF_Slicer4CARMAWorkflow.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* CARMA Project Beta release Demo Location: http://cni29.bwh.harvard.edu/SlicerWFDemo/index.php&lt;br /&gt;
&lt;br /&gt;
* Segmentation Workflows: Screenshots, scans' and study description : [[File:SlicerWF_EMSegmentProjectsReview.zip]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
= All Hands Meeting Pages =&lt;br /&gt;
* Salt Lake City 2011 Winter [http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA SLC_2011_WorkFlow]&lt;br /&gt;
* MIT 2010 Summer [http://wiki.na-mic.org/Wiki/index.php/Summer_project_week_2010_Workflows_SOA MIT_2010_WorkFlow]&lt;br /&gt;
&lt;br /&gt;
= Research Plan =&lt;br /&gt;
*Create a stand-alone SPINE desktop agent with fully functional data exchange and communication mechanisms towards 3D Slicer and XNAT.&lt;br /&gt;
*Develop Service Oriented Architecture (SOA) SPINE System that will include 3D Slicer image processing modules deployed as web services as well as a workflow management system to orchestrate interaction between 3D Slicer, XNAT, and 3-rd party tools.&lt;br /&gt;
*Implement two-way control and communications between 3D Slicer and SPINE modules.&lt;br /&gt;
*Adapt SPINE System for cluster and grid computing scenarios.&lt;br /&gt;
*Provide with workflow and 3D Slicer web service wrappers editing tools.&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:UseCaseScenarios| Use Case scenarios]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PETCTWorkflow| PETCTWorkflow]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:AgingStudySegmentation| AgingStudySegmentation]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:TwoTensorTractography| TwoTensorTractography]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:LongitudinalMultimodalityRegistrationSuite| LongitudinalMultimodalityRegistrationSuite]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:MigrationJavaClients2QT| MigrationJavaClients2QT]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PediatricMSSegmentation| PediatricMSSegmentation]]&lt;br /&gt;
*[[DBP3:Utah:RegSegPipeline| MRI-based study and treatment of atrial fibrillation]]&lt;br /&gt;
&lt;br /&gt;
= Application Server / Workflow Engine Downloads =&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:WFEngineDownloads| Download Links]]&lt;br /&gt;
&lt;br /&gt;
=Key Personnel=&lt;br /&gt;
* Charles Gutmann, MD., 4%,  9-17-2009 through 9-16-2011&lt;br /&gt;
* Alexander Zaitsev, Ph.D., 75%, 9-17-2009 through 9-16-2011 &lt;br /&gt;
&lt;br /&gt;
=Annual Progress Statements =&lt;br /&gt;
'''2010-11''' &amp;lt;br&amp;gt;&lt;br /&gt;
The  April 2011 – March 2011 period was devoted on developing portable workflow solutions that can be deployed on end-users' workstations or notebooks with minimal or no system administration activities. This is in contrast to the server-side deployment. The following scenarios had been deployed and used for actual projects that require the following types of workflows: PET/CT registration and computation of biomarker driven brain physiological activities, Brain MRI Images segmentation,  MRI and MRI Angiography images pre-processing for cardiac ablation outcome estimation. Some  workflows (like EM Segmentation) had been utilizing various scenarios, some research projects  (like evaluation of chemotherapy outcome) require two types of workflows to assess physiological and structural changes. Starting from the 4th Quarter of 2011, the migration project had been emerged in order to embed Workflow GUIs into newly developed Slicer4 Suite. The existing rich client Java GUI applications are being re-written as C++/QT Sliceletts units, new modules (such as cardiac ablation project support) are had been written from scratch. The latter are being deployed from the Slicer4 GUI and act at a liaison between Slicer4 and Application Server containing  workflow and Slicer modules deployed as services. The feedback from the end users indicates that Workflow approach for the complex processing improves productivity, aids to the processing standardization and contributes to the overall experience using 3D Slicer&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
=Quarterly Progress=&lt;br /&gt;
&lt;br /&gt;
* NAMIC Annual Progress Slides (April 2010 - March 2011):&lt;br /&gt;
&lt;br /&gt;
* '''1st Qtr, 2011''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study: Second release is under testing by end-users. &lt;br /&gt;
*** Added MRI registration to aid ROI drawing on PET scans&lt;br /&gt;
*** Improved SUV results reporting and added flexibility to update ROI lookup table&lt;br /&gt;
*** Automated EM Segmentation of MRI images for computing SUVs for white matter, CSF, and whole brain (80% completion)&lt;br /&gt;
*** Integration with SPECTRE scull stripping module (70% completion) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** EM Segmentation: Automated WF Pipelines are created &amp;lt;br&amp;gt;&lt;br /&gt;
*** Flexible atlas selection (Pediatric, etc) feature added&lt;br /&gt;
*** Workflows implemented for EM Segmenter 3.6.2 and 3.6.3 (1st Qtr 2011 release)&lt;br /&gt;
&lt;br /&gt;
** Cardiac ablation results follow-up: Workflow for registration and ROI selection of cardiac MRI and MR Angiography &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Wrokflow and Web Services for prospective DTI tractography modules (currently written as Matlab modules at PNL) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Web Services for SPECTRE Scull stripping module&lt;br /&gt;
*** Accuracy and performance tuning&lt;br /&gt;
*** 50% completion&lt;br /&gt;
&lt;br /&gt;
** Migration Front End GUI to Slicer4/QT:&lt;br /&gt;
*** EM Segmentation&lt;br /&gt;
*** Cardiac Ablation Study&lt;br /&gt;
&lt;br /&gt;
** DICOM Uploader and Desktop Browser for XNat Image repository (alpha version - tested for MGH MS Center studies, proposed to use with MI2B2 Clients and Services)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''4th Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study and EM Segmentation for Aging Study are deployed at end-user sites and actively used for research. &lt;br /&gt;
** Adopted EM Segmentation preprocessing pipeline for HIV Study: high resolution SPGR images, integration with FreeSurfer brainmask extraction outputs; integration of Slicer SPECTRE module for brainmask extraction is in progress.&lt;br /&gt;
** The following post-release upgrades had been implemented based on end-user feedback: Application Server basic controls are performed from Rich Client GUI as alternative to traditional IT administration activities. The controls are implemented on point-and-click bases and include web services and workflow application deployment and upgrades, application server start and stop as well as warning end user when the server is not accepting request.&lt;br /&gt;
** Added DICOM downloads and results uploads of PET/CT pipelines from and to XNat Repository&lt;br /&gt;
** Created Services and Workflow for Matlab Prototypes modules. Case Study: tractography for DTI images&lt;br /&gt;
** Extended XNAT integration services:&lt;br /&gt;
*** Browsing capabilities of XNat data repository from the Workflow Applications&lt;br /&gt;
*** Improved DICOM upload and download performance&lt;br /&gt;
*** Added Metadata organizing services for uploaded DICOM images: header data extraction, image snapshots creation. &lt;br /&gt;
** Started project for Rich Client GUI migration from Java desktop application to build into SLicer4 QT modules. This affects mostly front-end GUI and has the following approaches: distribution with the Slicer4, end-user will select desired workflow application from Slicer4 menu while QT-written modules provide with the same functionality as Java Rich Clients. Case Study for the Migration process: registration suite for longitudinal studies that include multi-modality images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* '''3d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Concentrated on building downloadable workflow applications that could run both in desktop (new) and server environment, and that require minimum IT administrative resources. The desktop deployment is in compliance with Slicer3 general deployment concept.&lt;br /&gt;
*** The following use case scenario had been chosen: PET/CT image processing for longitudinal studies, EM Segmentation for longitudinal Aging Study.&lt;br /&gt;
** Released workflow application for PET/CT image processing for longitudinal studies. Provided end users with training and documentation.&lt;br /&gt;
*** The PET/CT processing workflow was designed to be a general application used whenever both structural patterns and metabolic activities are within the research scope. &lt;br /&gt;
*** The desktop version is tuned to use minimal computer resources, so the automates processing instances do not interfere with human activities. Automated activities may include, for example, registration and PET scan's standard uptake values computing, and manual human activities may include image cropping, quality control, and labeling voxels of interest.&lt;br /&gt;
** Core services and EM Segmentation preprocessing workflow was build for retrospective Aging Study. Tuned the Slicer3 webservices for processing low grade images acquired in mid 90s. Entire workflow is implemented with Slicer3 only modules and can be deployed locally and on the servers. Usage of Service Oriented Architecture (SOA) as a core technological approach allowed reusing most of the web services that had been build for PET/CT project. &lt;br /&gt;
** Continued embedding Slicer3 application and modules into previously released processing pipelines: replaced MIPAV with Slicer3 GUI for lesion assessment step in the multi-center Pediatric MS Cohort image processing &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''2d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Completed Social Cognition Workflow Implementation. This includes EM Segmetnation pre- and post-processing pipelines, data tracking, and integration with 3d party image processing utilities, as well as processing results acquired manually with Slicer GUI.  &lt;br /&gt;
** Multi-modality image registration and ROI selection/alignment workflow for longitudinal studies. &lt;br /&gt;
*** Use case: PET/CT image processing for longitudinal studies. &lt;br /&gt;
*** Build portable library of Slicer modules as web services and workflow that are deployed and run on a end-users' worksatations without utilization of SPL and other servers. The web services include novel Slicer3 modules, such as BRAINSFit and BRAINSResamle &lt;br /&gt;
*** Started working with Slicer3 developers on Slicer 3.8 GUI wizard to communicate with workflow instances.&lt;br /&gt;
** Participated at NA-MIC Summer 2010 Project Week: [[Summer_project_week_2010_Workflows_SOA]]&lt;br /&gt;
&lt;br /&gt;
=Progress=&lt;br /&gt;
&lt;br /&gt;
* May 27, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Ready for deployment. New Features: hemispheres EM Segmentation, automated ICC/brainmask extraction using EM Segmenter, fixed controls for MRI conversion and registration&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 20, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General / PETCT V2.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Hemispheres EM Segmentation - adjusted for required label lookup table&lt;br /&gt;
* Use cases added for EM Segmenter General Project: http://www.slicer.org/slicerWiki/index.php/EMSegmenter-Tasks#EMSegmenter_use_cases&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SPECTRE Scull Stripping&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* The new version to be tested on coming week (After PETCT MRI processing migrated to Hemispheres scenario )&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* May 13, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General / PETCT V1.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Hemispheres EM Segmentation - technically works with labal values hardcoded in Slicer EM Segmenter - need to add manual label value edition step&lt;br /&gt;
* PETCT WF Cut for Java GUI (Pending Hemispheres label update completion). Next release will be in QT4.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* May 6, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (QA of EM Segmenter module, work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* April 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Open Discussion for Packaging WF QT Modules as Slicer4 extensions (waiting for SOPs)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review supported projects http://wiki.na-mic.org/Wiki/index.php/File:SlicerWF_EMSegmentProjectsReview.zip &lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (required by Study)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Slicer Modules General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Standardizing Crop Volumes Output (with A. Fedorov's module). Review for required updates of existing product (PET/CT, CARMA)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Open Discussion for Packaging WF QT Modules as Slicer4 extensions (waiting for SOPs)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review supported projects http://wiki.na-mic.org/Wiki/index.php/File:SlicerWF_EMSegmentProjectsReview.zip &lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (required by Study)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Slicer Modules General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Standardizing Crop Volumes Output (with A. Fedorov's module)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 22, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Beta release ready. Demo Location: http://cni29.bwh.harvard.edu/SlicerWFDemo/index.php&lt;br /&gt;
* TODO: Tutorial. Original inputs copy/renaming&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 15, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Adding App server auto-config features&lt;br /&gt;
* Finalizing the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 08, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Second release beta build tested on cosutmer side &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review registration quality (with Dr. Meier). Angiography images' Resampling tuned. &lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 01, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the second release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
XNat Integration&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* (Java) GUI for Project Browsing and DICOM Series Upload. Post-upload DICOM processing tested and debugged&amp;lt;br&amp;gt;&lt;br /&gt;
* Ready for integration with mi2b2 client.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Migrated to Latest Slicer 3.6.3 stable release: only the Input scene had to be updated, the API remained the same&lt;br /&gt;
* Tested EM Segmenter with CMTK4Slicer extension - processing takes to much time on Linux_64bit machine, rolled back to BRAINSFit registration. When used on Mac OS X build, the Slicer could not start (bug report 1126).&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SPECTRE Scull Stripping:&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Testes for various use cases: the module is extremely sensitive to T1 MRI quality (does not work for most MRIs from PET/CT project&lt;br /&gt;
* TODO next week: check for FLAIR images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Slicer4 QT GUI and Cropping activity in progress.&amp;lt;br&amp;gt;&lt;br /&gt;
* Tried direct MRA to MRA registration option: resampling with LMRI registration transforms works better.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Extra VOI labels revised&lt;br /&gt;
* Debugging of SUV results' renormalization step&lt;br /&gt;
* TODO: ICC extraction / whole brain total uptake computing; EM Segmentation for R_WM, L_WM SUV computing and BPH estimation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SCULL STRIPPING/SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Installed and tested CLI option on Linux_64bit platform&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Workflow interruption before BSPline registraton: BPEL Module completed. Slicer4 QT GUI and Cropping activity in prorgess.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Implemented and Tested with end-users proposed changes: denormalization of SUV results, adding more VOI labels, added FLAIR MRI in addition to T1s for VOI drawing&lt;br /&gt;
* Tested manual ICC extraction using PET scans: works satisfactory with island removal and cropping followed by threshold level labeling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4&lt;br /&gt;
* Change proposed: interrupt workflow after affine registration and have user crop the VOI. This is to prevent excessive deformations for BSpline registration and resampling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4. User has option to choose the atlas that fits better for the given subject (NOTE: hardcoding must be rewritten for atlas linking)&lt;br /&gt;
* PETCT test - the problem is that T1s are low resolution and with contrast. Proposed using T1s without contrast&lt;br /&gt;
* PETCT change request: users wants to compute SUV for entire ICC. Had demo how to segment brainmask/ICC using PET scan. The derived brainmask label can be used for SUV computation.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - cmpleted&lt;br /&gt;
* Sample cases run - excessive deformation after BSpline registration hase&lt;br /&gt;
* Next week plan - pull tuning controls to front-end of pipeline API, start working of QT module for CARMA registration&lt;br /&gt;
* May consider other than BRAINSFit registration modules&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Design plan for change request: more VOI labels, add FLAIR in addition to T1 for VOI drawing, T1s segmentation&lt;br /&gt;
* Tested segmentation for sample cases - artifacts from poor quality MRIs lead to exclusion of parts of ICC from segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Completed troubleshooting of EMSegmenter module calling from Java (need TCL libs to be pulled from Slicer environment)&lt;br /&gt;
* Tested EMSegmenter autoruns for HIV and Pediatric MS patiens. Work as expected, subject to improvement of PED MS case segmentation by building better skull/neck/air atalses&lt;br /&gt;
* Suggested usage of two subsets of atalases: with and without neck. The Subject MRIs have to be cropped accordingly or best fit atlas has to be selected&lt;br /&gt;
* Made no-neck cropped atlas collection for default EMSegmenter scenario&lt;br /&gt;
* Tested with PET/CT study MRI cases - see above &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - in progress&lt;br /&gt;
* Next week goal - have back end processing ready&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Longitudinal Study&lt;br /&gt;
* Added MRI registration to the pipeline&lt;br /&gt;
* Troubleshooting of complex XML schema issues on Linux machines (some modules working on MAC do not work on Linux). As a workaround - did not include MRI convert and register part into base BPEL module. Used separate services (transparent for end-user)&lt;br /&gt;
* TODO next week for change request completion: explicit pixel type casting for MRI in BRAINSFit, VOI MRML scene update (currently MRI added on top of schema)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* February 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipeline for Pediatric MRI. Same scenario as for HIV Project, icbm pediatric atlases (Completed, verified)&lt;br /&gt;
* Collected NIH healthy brain development atlases: various age ranges from 4.5 to 18 yo. Converted to Slicer readable format &lt;br /&gt;
* Work on web services for the new automated EM Segmenter module (release Nov 10 - current). Verified task completion both for adult and pediatric images. Discussed tuning parameters for work load balance on workstations.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Started working on MRI registration to the reference CT scans. &lt;br /&gt;
* Design specs for optional White Matter segmentation for SUV computing.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* February 4, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipelines for Pediatric MRI (in progress)&lt;br /&gt;
* Adapting Pediatric T1 atlases for &amp;quot;Human Brain&amp;quot; build-in EM Segmentation wizard (in progress)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 28, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Verifying EM Segmenter module for latest builds and HIV/PED MS Studies (report pending)&lt;br /&gt;
* Work with SPECTRE module developers with pediatric MRI brainmask extraction&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* January 21, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Compiling plan for WF FrontEnd GUI migration to Slicer4/QT Widgets&lt;br /&gt;
* Preparing for annual progress report&lt;br /&gt;
&lt;br /&gt;
* January 14, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI: Integrated into the Slicer4 as Slicelet (or thin Client)&lt;br /&gt;
* Participation at AHM-2011, discussing integration of SPECTRE module and updated approach to EM-Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA&lt;br /&gt;
&lt;br /&gt;
* January 7, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* HIV project workflow delivered. Major additions relate to user convenience: &lt;br /&gt;
- Project-specific parameter settings, importing T1s and brainmasks from FreeSurfer outputs with conversion to NIFTI, resampling brainmask to original scans and automatied subject addition.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Follow up with end user: need to add MRI scans, if available, addition and registration to CT in order to ease VOI drawings.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
 &lt;br /&gt;
* December 31, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Follow-up with user Experience for AGING Study Segmentation (Positive feedback)&lt;br /&gt;
* Target date for HIV project delivery - next week&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Self-training for QT widget development&amp;lt;br&amp;gt;&lt;br /&gt;
* Outlined Workflow Rich Clients migration strategy from Java to QT/Slicer4:&amp;lt;br&amp;gt;&lt;br /&gt;
** Use Java Stubs (similar to SPECTRE integration) or file binding for envocation of workflow pipelines. (See SOAP remark below)&lt;br /&gt;
** Direct Web Servisec calls must be wrapped into REST protocol. The reason: NON-commerchial QT kit does not include SOAP protocol for web servises.&lt;br /&gt;
** The GUI will be implemented as page widget or QT dialog GUI forms called from within Slicer4.&lt;br /&gt;
** Communications between Slicer4 and WF GUI will be set via child-parent and signal-slot relations&lt;br /&gt;
* Worked on a Prototype for Basic EM Segmentation QT widget (70% complete). Will work on integrtion with SLicer4 during the AHM-2010&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
XNAT Integration&lt;br /&gt;
* Debugged XNAT RESTFul API usage for uplaoding DICOM series followed by header data extraction and image snapshots creation&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Added compensation for failed atlas registration (subject for old poor quality pseudo-T1 images): blank probability maps are created in case of failure.&lt;br /&gt;
* Data preparation module for FreeSurfer data import near completion. Expected time for deployment at end-users workstations - first week of January&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Discussed strategy for EM Segmentation pipeline solutions collection (K. Pohl, R. Kikinis)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* RE-using the same core workflow as for 1-channel EM Segmentation of AGING STUDY cases&lt;br /&gt;
* Added data input preparation module: ICC label mask preparation and skull-stripping based on FreeSurfer brainmask output volume.&lt;br /&gt;
* Two-channel EM segmentation pipeline (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE / GENERAL Development &amp;lt;br&amp;gt;&lt;br /&gt;
* Worked on plans for migrating fro rich workflow Java clients to embedded workflow windows inside the Slicer.&amp;lt;br&amp;gt;&lt;br /&gt;
The embedded workflow management clients are to be implemented with QT/PyQT toolkits&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
INTEGRATION WITH XNAT:&amp;lt;br&amp;gt;&lt;br /&gt;
* Automated DICOM series upload with triggering DICOM headers parsing at XNat site (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress. &lt;br /&gt;
- Results upload to XNat (Completed) &amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat based on user's input (Project + Subject + PET or CT session / scan) (Completed)&amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat - perfomance boosting solution for downloads found , web services services are created, relinking for the client side in progress &amp;lt;br&amp;gt;&lt;br /&gt;
- Xnat querying for subjects and automated subject addition into the workflow (In Progress) &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-segmentation module added for auto correction of segmentation results. Particularly - relabeling CSF voxels segmented as Air inside the intracranial cavity. This was requested by end-users after processing images with zero-signals in CSF voxels &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting automated dual-echo DICOM images conversion and split into two NRRD volumes&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT / EM Segmentation pipeline:&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting memory allocation issues for scull-stripping module SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
COPD Project:&amp;lt;br&amp;gt;&lt;br /&gt;
* Benchmark test for accelerated DICOM downloads from XNat (remoote XNat Central server): we can handle at least 6 cases (4 CT scans in each) per hour, which is compatible with current workload quotes on SPL cluster processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* December 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Deployed Version 1. &amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Test project chosen as a closest match to registration scenario: Pediatric MS Cases from MGH - requires periodic image preview for different &lt;br /&gt;
modalities taken from vaious time points. Label maps for VOIs resampling is also required.&lt;br /&gt;
&lt;br /&gt;
* November 26, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user. Version 1 is complete&amp;lt;br&amp;gt;&lt;br /&gt;
* Started working on integration with XNat&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on input data organizing modules&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 19, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user (70% done)&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Universal Registration Workflow for Longitudinal Studies - design specs in progress&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 12, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Minor tuning to EM Segmentation template as of users' feedback&lt;br /&gt;
* Users started using the workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed input data conversion from Genesis to Slicer native or NIFTI format. Our help may be needed in input data organizing.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Tuned application according to co-laborators (PNL) needs&amp;lt;br&amp;gt;&lt;br /&gt;
* The webservices and BPEL workflow application are tested ready to accept computation requests from PNL case tracking system &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Discussed Universal Registration Workflow for Longitudinal Studies&lt;br /&gt;
* Started the thread about possible cooperation with Children hospital's image processing pipelines and integration with Xnat &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 5, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Webservices and workflow pilot project created and deployed on Psychiatry Neuroimaging Laboratory subnet &amp;lt;br&amp;gt;&lt;br /&gt;
* The V.1.0 deployment is scheduled for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 29, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Most of functionality is completed. Some volume statistics post processing is pending&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL EM SEGMENTATION Pipeline: &amp;lt;br&amp;gt;&lt;br /&gt;
* The SPECTRE scull stripping module. Started integration into EMS workflow. Made some test runs from Slicer GUI&amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Identified as a candidate for Workflow Application&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 22, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* All back-end functionality are implemented&amp;lt;br&amp;gt;&lt;br /&gt;
* EM Segmentation scene usability is confirmed by end-user&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for next week: add Label Statistics computation for CSF/Brain/ICC &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 15, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* The latest (October) builds of Slicer 3.6.2 produced acceptable results. This was verified by the target users. The EM Segmentation will be performed on Slicer 3.6.2 or later&amp;lt;br&amp;gt;&lt;br /&gt;
* The new Web services had been created and added to the pipeline as optional processing steps: Biasfield correction (implement novel N2ITKBiasFieldCorrection module) and Volume's scalar datatype casting (as workaround for Biasfield correction module not preserving image scalar datatype - the bug is filed) &amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed the Front-End GUI design with target users. The design pattern is taken from the PETCT project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 8, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-deployment support. Tuned CT registration as of user's feedback.&lt;br /&gt;
* Adapting to the Single Slicer build: Slicer 3.6.2. Found label duplicates in the label lookup table - will ask user if it's tolerable. Waiting for the Slicer 3.6.2 build that contains all required modules. Rolling back label tag appending code for SUVs - the latest Slicer build appends the tags.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Resumed development. The priorities are set for usage of Slicer 3.6.2 - subject for EM Segmentation scene tuning. Continued coding for Scene creation for Slicer 2.8 - as a backup option for ongoing research project.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 1, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized V1.0 release based on end-user feedback: updates relate mostly to error proofing and SUV values representation&lt;br /&gt;
* Post-deployment support. Users pre-processed first set of patients &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* September 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* System deployed and tested at End Users' site.&amp;lt;br&amp;gt;Users are trained to perform all tasks required by the workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
* Got positive feedback with suggestions on Slicer Scenes' layouts improvement and PET scans' SUV (standard uptake values) results display&lt;br /&gt;
* Two distribution packages are assembled: Lunix and MAC OS versions. The difference in two packages is in specific Slicer3.6/3.7 builds - subject to Slicer Linux builds debugging.&amp;lt;br&amp;gt; As a workaround for Linux deployment - multiple Slicer builds are used to perform various tasks (registration, opening editing scenes in Slicer, SUV computing)&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for coming week - finalize V1.0 release based on end-user feedback&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Embedded SUV computations into the workflow (as system calls - will be translated into web service later)&amp;lt;br&amp;gt;&lt;br /&gt;
* Pre-release demo for end users.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Create and debug EM Segmenter scenes template for Slicer 3.6 and 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* September 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation - workflow pipeline and deployment verified&amp;lt;br&amp;gt;&lt;br /&gt;
* Tested EM Segmentation scenes within Slicer 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
* Started migration of EM Segmentation to Slicer 3.6. Discovered issues had been reported to EM Segmenter module designers &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* August 29 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation completed. Preprocessing Pipleine completed 80% (subject for input registration parameters tuning) &amp;lt;br&amp;gt;&lt;br /&gt;
* Most webservices (for registration and resampling steps) had been taken and re-used from PET/CT ROI/Longitudinal Study - showing the advantage of service-oriented software design and deployment.&lt;br /&gt;
* Continued on distribution and deployment of the service/workflow applications: on PET/CT and AGING STUDY projects.&lt;br /&gt;
&lt;br /&gt;
PEDIATRIC Multiple Sclerosis Cohort. Support of multi-center distributed processing project&amp;lt;br&amp;gt;&lt;br /&gt;
* Introduced Slicer 3.6 for the MS Lesion Assessment step performed at Mayo Clinic. Images are being transferred from image repository at BWH and automatically opened and arranged within Slicer GUI for reading.  This was replacement of Client GUI using MIPAV that stopped working on new computers at Mayo Clinic.&lt;br /&gt;
The images are being loaded via generated MRML Scenes same way as in PET/CT and AGING STUDY projects &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* August 22 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Preprocessing pipeline merge with SUV computations &amp;lt;br&amp;gt;&lt;br /&gt;
- QA for SUVs computation was performed by Wendy Plesniak for images with known uptake values. &amp;lt;br&amp;gt;&lt;br /&gt;
- Discovered that image cropping step (not related to automated registration pipeline and SUVs computing) smoothes the images by doing interpolation when used with default settings. Got suggestions from Steve Piper using Nearest-Neighbor interpolation (&amp;quot;no interpolation&amp;quot;) for a time being&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
- This is the new project candidate. Requested for the images with failed manual segmentation and/or segmentation with FreeSurfer. The EM Segmentation run showed most acceptable results on one of the problem images back in February &amp;lt;br&amp;gt;&lt;br /&gt;
- The workflow will be developed and deployed similar to PET/CT ROI Longitudinal study approach - all preprocessing steps will be done with Slicer modules, all runs will be performed on local end-user machines.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
 &lt;br /&gt;
&lt;br /&gt;
* August 15 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- First 5 cases with 3-4 time points preprocessed for SUVs computation&lt;br /&gt;
&lt;br /&gt;
* August 8 2010&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Testing of installation and operation at users' site (Performed by Wendy Plesniak)&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* July 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Delivered beta version of registration pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
- Prepared installation and user manuals &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* June 11, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Registration modules completed &amp;lt;br&amp;gt;&lt;br /&gt;
- Irregular cases registration problem solved (when whole body and brain only scans are mixed for a timepoint)&amp;lt;br&amp;gt;&lt;br /&gt;
- Live demo of case setup and registration workflow for end users. Real case with 4 timepoints used&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Coming week plans&amp;lt;br&amp;gt;&lt;br /&gt;
- Adjust workflow based on end users' feedback&amp;lt;br&amp;gt;&lt;br /&gt;
- Integration with SUVs computing for PET scans&amp;lt;br&amp;gt;&lt;br /&gt;
- GUI for workflows dispatching and data organizing&amp;lt;br&amp;gt;&lt;br /&gt;
- (TBD) Integration with 4D time series analysis Slicer module&amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
* May 28, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- Migration to the latest Slicer 3.6 release candidate &amp;lt;br&amp;gt;&lt;br /&gt;
- Added webservice for new registration module: BRAINSFit &amp;lt;br&amp;gt;&lt;br /&gt;
- Test runs for new patients with 4 timepoints' scans &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Plans for next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI &amp;lt;br&amp;gt;&lt;br /&gt;
- processing workflow demo for end user &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 21, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Pilot version of portable web services and automated workflow tested: &amp;lt;br&amp;gt;&lt;br /&gt;
Linux: workflow and visual review passed&amp;lt;br&amp;gt;&lt;br /&gt;
Stress test for 25 timepoints passed &amp;lt;br&amp;gt;&lt;br /&gt;
MAC OS: workflow passed, visual review failing when PET/CT images are loaded into GUI simultaneously (bug report submitted)&amp;lt;br&amp;gt;&lt;br /&gt;
Windows: need to adapt command line modules and workflow management system to sygwin environment&amp;lt;br&amp;gt;&lt;br /&gt;
Plans for next week: integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI&lt;br /&gt;
&lt;br /&gt;
* May 7, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Selected registration and resampling modules with more precise and stable outputs. &amp;lt;br&amp;gt;&lt;br /&gt;
Started building portable web services and automated workflow &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 30, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- manual walk through the processing steps: ROI cropping, registration/resampling, PET pharmaceutical DICOM data retention. &amp;lt;br&amp;gt;&lt;br /&gt;
- testing workflow and web services packages distribution to end-users' machines&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* April 23, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : testing various registration and re-sampling algorithms (work in progress)&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation: as of collaborators' request, run existing EM Segmentation workflow for older low resolution pseudo-T1 images. The EM Segmentation works for those images with manual sampling. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 16, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
  Social Cognition Study: started Cortical Thickness Measurement module build (bases on NA-MIC ARCTIC pipeline) &amp;lt;br&amp;gt;&lt;br /&gt;
  PET/CT ROI/Longitudinal Study Registration : Design specs, PET-to-CT images registration tests on training data. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 9, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. GUI update based on end-user experience.&amp;lt;br&amp;gt;&lt;br /&gt;
User request: automated label maps' volumes calculation (Currently possible from Slicer3 GUI)&amp;lt;br&amp;gt; &lt;br /&gt;
PET/CT ROI Project. Initial design specs discussion with end-users and co-developers&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure&lt;br /&gt;
Verification of segmentation workflow GUI: from registering new case to reviewing results&amp;lt;br&amp;gt;&lt;br /&gt;
Cross study test of segmentation workflow: MGH/MS Center data - success,  HIV Project data - some EM Segmentation scene tuning is needed &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*&lt;br /&gt;
* April 2, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. Segmentation workflow completed&amp;lt;br&amp;gt;&lt;br /&gt;
* Coming Week plans:&amp;lt;br&amp;gt;&lt;br /&gt;
- Document Segmentation Workflow. Follow up with end users &amp;lt;br&amp;gt;&lt;br /&gt;
- Start with Cortical Thickness and ROI-in-longitudinal studies workflows&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* March 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All essential processing and workflow interaction clients are ready.&amp;lt;br&amp;gt;&lt;br /&gt;
- Completed segmentation for 10 out of 50 patients. The remaining cases will be finalized upon manual lesion segmentation and QC verification of WM/GM/CSF and Deep GM segmentation's. &amp;lt;br&amp;gt;&lt;br /&gt;
- TODO next week: refine QC GUI and data tracking / progress monitoring schema. &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&amp;lt;br&amp;gt;&lt;br /&gt;
- New Slicer3 web services added: re-slicing with reference image volume, casting image scalar type &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
* March 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Segmentation maps Merging Services for GM/WM/CSF (Slicer EM Segemnter), Lesion (Slicer, Manual), and Deep GM (FreeSurfer)  &amp;lt;br&amp;gt;&lt;br /&gt;
- Deep GM segmentation pipeline adopted as optional service for Social Cognition Study (22 out of 50 cases processed) &amp;lt;br&amp;gt;&lt;br /&gt;
- (In progress) GUI client for Launching Segmentation results merging with optional Deep GM segmentation with FreeSurfer &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- Complete GUI Client for Segmentation result merging &amp;lt;br&amp;gt;&lt;br /&gt;
- Progress Monitoring services for entire Study processing: EM Segmenter Preprocessing, EM Segmentation, Lesion Segmentation (including human activities assignments), Deep GM segmentation, and results consolidation. &amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* March 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All 50 cases went through &amp;quot;basic&amp;quot; One-channel EM segmentation (GM/WM/CSF) &amp;lt;br&amp;gt;&lt;br /&gt;
- Basic pipeline start-up command line client created: user has two options - request brainmask extraction or provide with previously extracted brainmask for a given subject &amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison of GM/WN/CSF performed for Slicer EM Segmenter and FreeSurfer recon-all (used with default settings). &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmenter provides more accurate output &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmentation pipeline runs faster (40 minutes vs 12 hrs when no brainmask extraction requested) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO:&amp;lt;br&amp;gt;&lt;br /&gt;
- merging modules for automatic 1-channel EM segmentation and manual lesion segmentation &amp;lt;br&amp;gt;&lt;br /&gt;
- Emerge Cortical Thickness pipeline project: use NAC ARCTIC processing steps and modules &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Selected stable EM Segmentation scenario: White Matter, Gray Matter, and Cerebrospinal Fluid &amp;lt;br&amp;gt;&lt;br /&gt;
- First 16 cases are segmented for selected scenario. Nine more cases are preprocessed for EM Segmentation.&amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison to segmentation with FreeSurfer showed better accuracy for Slicer2 EMSegmenter &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure &amp;lt;br&amp;gt;&lt;br /&gt;
- Three prerpcocessed cases failed during volume ICC masking with in-house build utility. Evaluated switching to Slicer3 Mask and island removing modules.&amp;lt;br&amp;gt;&lt;br /&gt;
- Initial design specs discussion for cortical thickness measurement pipeline. ARCTIC pipeline selected. ARCTIC preprocessing steps signifficantly overlap with EM Segmentation preprocessing workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
  &lt;br /&gt;
* February 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: &amp;lt;br&amp;gt;&lt;br /&gt;
A) parameters tuning for EM Segmenter itself (work with EM Segmenter developer), template scenes creation &amp;lt;br&amp;gt;&lt;br /&gt;
B) update preprocessing pipeline - deep gray matter atlases included &amp;lt;br&amp;gt;&lt;br /&gt;
C) test and debug preprocesing pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
D) identified missing modules: atlas autocalibration for EM Segmentation scene, Island removal for ICC mask&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- Review currently deployed modules. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: reviewed firts seven subjects' outputs, added volume orientation module into pipeline (prevents ICBM atlas linear registration failures)&amp;lt;br&amp;gt;&lt;br /&gt;
- Fused ICC(brainmask) extraction module with EM Segmenter preprocessing. Three scenarious implemented: start with pre-extracted ICC mask (longitudinal studies case), run with ICC ectration, run with ICC extraction AND ICC correction before ICBM atlas preporcessing. &amp;lt;br&amp;gt;&lt;br /&gt;
- Completion of Human activities GUI (QC, ICC Correction) planned for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: Volume Orientation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: automated preprocessing pipeline for Slicer2 EM Segmenter test version deployed. Seven cases pre-processed.&lt;br /&gt;
- PET Quantitative measurements: Preliminary design specs discussion.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: BSplineRegistration (for non-linear registration), ResampleVolume2 (for atlases resampling based on image atlase templates registration). Local and Network runs are implemented, Cluster/GridWizard implementation pending.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Slicer EM Segmenter module: preprocessing design for Slicer2 EM Segmenter&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Adapting for Slicer2 EM Segmenter (mostly from pipelines and services for previous projects)&lt;br /&gt;
  -- Integration with FreeSurfer modules for bisafield correction, brainmask extraction, and linear registration of ICBM atlases&lt;br /&gt;
  -- Preprocessing updates for non-linear registration of ICBM atlases with Slicer2 (image re-orientation service designed)&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 29, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- EM Segmentaton pipeline: preprocessing results are being transferred to XNat (anonymized data, Central XNat) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Slicer EM Segmenter module: discussed agenda and scheduled a work meeting for Social Cognition Study image segmentation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Testing stage, 95% completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- SPL XNat server: verified data exchange via RESTfull web services.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 22, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Follow up with White Matter Lesion Segmenter and Scull Stripping Modules developers: Work in Progress&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Work in Progress, 60%+ completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Discussed SPINE image repository migration to XNat&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 15, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. &lt;br /&gt;
- Social Cognition Study: &lt;br /&gt;
Work-in-progress on intermediate (reconstruction) and results (resources) data storage at XNat.&lt;br /&gt;
&amp;lt;br&amp;gt;Reviewing and preparation more cases for EM Segmentor (Slicer 3.5) tuning.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* NA-MIC Project Week&lt;br /&gt;
Selecting candidate Slicer modules for other than Lesion EM Segmentation topics of Social Cognition study: Withe Matter Lesion Segmenter (UNC), Scull Stripping utility from UIOWA.&lt;br /&gt;
Reviewing issues of currently used Scull Stripping Slicer Extension and Slicer 3.5 EM Segmenter.&lt;br /&gt;
&amp;lt;br&amp;gt;XNat Data organizing training&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 1, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Preparation of Demo for NA-MIC work week: &lt;br /&gt;
- COPD Study. Added Remote pipepline start interface (represents real world scenario where Xnat repository, Processing modules and User are at different sites)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
- EM Segmentation. Added human activities steps to the workflow: ICC (brainmask) correction and EM Segmantation scena load per se.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 25, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Pilot workflow pipeline for EM Segmentation (all steps except user-activity step: ICC correction assignment and tracking)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 18, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Build and tested web services for EM Segmentation image preprocessing: DICOM-to-NRRD conversion, registration, skull stripping, image masking.&lt;br /&gt;
Started building workflow pipeline (subject to finish first version next week)&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Started Collecting Library of Slicer Build number vs. functional modules and extensions.&lt;br /&gt;
Plan for NAMIC project week: scheduled meetings for XNat data customization, Skull-stripping modules tuning, identified Social Cognition study cases that fail EM Segmentation processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 11, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Updating and verification of EM Segmentation Scenario&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Projects:ARRA:SlicerWF:UseCaseScenarios#Usecase_MS_lesion_Assessment&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Familiarizing with Slicer3.4/5 Modules required for implementation of EM Segmentation Scenario. Participation in debugging and/or usage tuning of Dicom Conversion, Registration, Skull Stripping, Masking, and Image Casting modules. &lt;br /&gt;
&lt;br /&gt;
* December 4, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Slicer3.4's EM Segmentation and Visual QC as part of image processing pipeline for Social Cognition Study for MS Patients.&lt;br /&gt;
Project emerged. EM Segmentation template creation debugged.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
Emphysema Measurements (COPD Study) - workflow stability and scalability test.&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 27, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Emphysema Measurements (COPD Study).&lt;br /&gt;
Added compensation for long running calculations and time-outs to the main computing pipeline.&lt;br /&gt;
Visual QC (work in progress)&lt;br /&gt;
** Infrastructure&lt;br /&gt;
XNat data structure customization, metadata storage, results consolidation: new feature request list creation (work in progress)&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 13, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
*** Pilot system for whole processing cycle for Emphysema Measurements (COPD Study) including the following:&lt;br /&gt;
Web query for CT session file list download&lt;br /&gt;
Pilot user interface for submitting the file list and starting processing pipeline&lt;br /&gt;
Notification about processing steps and failures&lt;br /&gt;
Upload results to XNat repository (at this stage results are uploaded into same folder where original scans are(*))&lt;br /&gt;
*** Immediate Plans&lt;br /&gt;
Complete Visual QC module&lt;br /&gt;
Design and implement meta-data transfer to XNat (including processing details and MRML files for loading images into the 3D Slicer)&lt;br /&gt;
&lt;br /&gt;
(*)Customization of results storage&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 6, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Tuned and debugged multiple subjects processing for: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat.&lt;br /&gt;
***Started working on quality control embedding into the above scenario. Plan to complete and video-record demo next week.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***Published general Product Integration scenario flow chart to collaborators' community. Discussion is open and in progress&lt;br /&gt;
&lt;br /&gt;
* October 30, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Piloted and tested the sequence: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat(1).&lt;br /&gt;
***Performance test of overall cycle: data transfer from remote serve is a bottleneck as expected&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data browsing features reviewed.&lt;br /&gt;
(1) Not automated yet&lt;br /&gt;
* October 23, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Defined COPD processing scenario with interoperability between Xnat, 3D Slicer Command Modules, Workflow, and Gridwizard Enterprise.&lt;br /&gt;
***Pilot version of Emphysema Measurements workflow pipeline deployed.&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data transfer features reviewed. Use account at XNat Central during learning curve.&lt;br /&gt;
***Feasibility test of 3D Slicer fiducials module for ROI highlights during QC and manual image processing activities. &lt;br /&gt;
* October 16, 2009&lt;br /&gt;
**Lung CT Scans Processing. Pilot project emerged. GenerateEmphysemaMeasurements module deployed as a webservice that submits jobs to computational cluster.&lt;br /&gt;
**EM Segmentation. Familiarized with GUI steps. Started working on automation steps outlining&lt;br /&gt;
**3D Slicer and XNat interaction. Got an overview from Wendy Plesniak.&lt;br /&gt;
* October 1 - 7, 2009&lt;br /&gt;
**Selected two first priority Projects: EM Segmentation of brain MRI images; Lung CT Scans Processing (COPD Study)&lt;br /&gt;
**Got initial outline of user requirements and design specs&lt;/div&gt;</summary>
		<author><name>Azaitsev</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=67280</id>
		<title>Projects:ARRA:SlicerWF</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=67280"/>
		<updated>2011-05-23T16:13:20Z</updated>

		<summary type="html">&lt;p&gt;Azaitsev: /* Progress */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Projects:ARRASuplements|Back to Slicer ARRA home page]]&lt;br /&gt;
= Aim =&lt;br /&gt;
Supplement 3D Slicer and Extensible Neuroimaging Archive Toolkit (XNAT) with workflow management system. Provide integration and interoperability between 3D Slicer, XNAT Services and 3-rd party image processing applications and high performance computing systems. Implement it as within currently developed Structural Planning and Implementation in Neurological Exploration (SPINE) System.&lt;br /&gt;
&lt;br /&gt;
= SPINE Project Documentation =&lt;br /&gt;
[http://cni.bwh.harvard.edu/projects/spine/index.html SPINE Docs]&lt;br /&gt;
&lt;br /&gt;
= Presentations =&lt;br /&gt;
* Segmentation Workflow. PECS University Social Cognition Study.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:SlicerWF_NAC_PECS_Workflow.pdf]]&lt;br /&gt;
* EAB10_ARRA Annual Progress Report Slides.&amp;lt;br&amp;gt;&lt;br /&gt;
[[media:EAB10_ARRA_WF_2011_Zaitsev.ppt | Service Oriented Solutions for 3D Slicer. EAB10_ARRA_WF_2011. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:EAB10_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:NAMIC_ARRA_WF_2011_Zaitsev.ppt  | NAMIC Annual Report 04/2010-03/2011. NAMIC_ARRA_WF_2011_Zaitsev. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:NAMIC_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:Slicer_WF_Slicer4CARMAWorkflow.ppt  | CARMA Workflow. Cardiac Ablation Followup. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:Slicer_WF_Slicer4CARMAWorkflow.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* CARMA Project Beta release Demo Location: http://cni29.bwh.harvard.edu/SlicerWFDemo/index.php&lt;br /&gt;
&lt;br /&gt;
* Segmentation Workflows: Screenshots, scans' and study description : [[File:SlicerWF_EMSegmentProjectsReview.zip]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
= All Hands Meeting Pages =&lt;br /&gt;
* Salt Lake City 2011 Winter [http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA SLC_2011_WorkFlow]&lt;br /&gt;
* MIT 2010 Summer [http://wiki.na-mic.org/Wiki/index.php/Summer_project_week_2010_Workflows_SOA MIT_2010_WorkFlow]&lt;br /&gt;
&lt;br /&gt;
= Research Plan =&lt;br /&gt;
*Create a stand-alone SPINE desktop agent with fully functional data exchange and communication mechanisms towards 3D Slicer and XNAT.&lt;br /&gt;
*Develop Service Oriented Architecture (SOA) SPINE System that will include 3D Slicer image processing modules deployed as web services as well as a workflow management system to orchestrate interaction between 3D Slicer, XNAT, and 3-rd party tools.&lt;br /&gt;
*Implement two-way control and communications between 3D Slicer and SPINE modules.&lt;br /&gt;
*Adapt SPINE System for cluster and grid computing scenarios.&lt;br /&gt;
*Provide with workflow and 3D Slicer web service wrappers editing tools.&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:UseCaseScenarios| Use Case scenarios]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PETCTWorkflow| PETCTWorkflow]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:AgingStudySegmentation| AgingStudySegmentation]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:TwoTensorTractography| TwoTensorTractography]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:LongitudinalMultimodalityRegistrationSuite| LongitudinalMultimodalityRegistrationSuite]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:MigrationJavaClients2QT| MigrationJavaClients2QT]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PediatricMSSegmentation| PediatricMSSegmentation]]&lt;br /&gt;
*[[DBP3:Utah:RegSegPipeline| MRI-based study and treatment of atrial fibrillation]]&lt;br /&gt;
&lt;br /&gt;
= Application Server / Workflow Engine Downloads =&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:WFEngineDownloads| Download Links]]&lt;br /&gt;
&lt;br /&gt;
=Key Personnel=&lt;br /&gt;
* Charles Gutmann, MD., 4%,  9-17-2009 through 9-16-2011&lt;br /&gt;
* Alexander Zaitsev, Ph.D., 75%, 9-17-2009 through 9-16-2011 &lt;br /&gt;
&lt;br /&gt;
=Annual Progress Statements =&lt;br /&gt;
'''2010-11''' &amp;lt;br&amp;gt;&lt;br /&gt;
The  April 2011 – March 2011 period was devoted on developing portable workflow solutions that can be deployed on end-users' workstations or notebooks with minimal or no system administration activities. This is in contrast to the server-side deployment. The following scenarios had been deployed and used for actual projects that require the following types of workflows: PET/CT registration and computation of biomarker driven brain physiological activities, Brain MRI Images segmentation,  MRI and MRI Angiography images pre-processing for cardiac ablation outcome estimation. Some  workflows (like EM Segmentation) had been utilizing various scenarios, some research projects  (like evaluation of chemotherapy outcome) require two types of workflows to assess physiological and structural changes. Starting from the 4th Quarter of 2011, the migration project had been emerged in order to embed Workflow GUIs into newly developed Slicer4 Suite. The existing rich client Java GUI applications are being re-written as C++/QT Sliceletts units, new modules (such as cardiac ablation project support) are had been written from scratch. The latter are being deployed from the Slicer4 GUI and act at a liaison between Slicer4 and Application Server containing  workflow and Slicer modules deployed as services. The feedback from the end users indicates that Workflow approach for the complex processing improves productivity, aids to the processing standardization and contributes to the overall experience using 3D Slicer&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
=Quarterly Progress=&lt;br /&gt;
&lt;br /&gt;
* NAMIC Annual Progress Slides (April 2010 - March 2011):&lt;br /&gt;
&lt;br /&gt;
* '''1st Qtr, 2011''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study: Second release is under testing by end-users. &lt;br /&gt;
*** Added MRI registration to aid ROI drawing on PET scans&lt;br /&gt;
*** Improved SUV results reporting and added flexibility to update ROI lookup table&lt;br /&gt;
*** Automated EM Segmentation of MRI images for computing SUVs for white matter, CSF, and whole brain (80% completion)&lt;br /&gt;
*** Integration with SPECTRE scull stripping module (70% completion) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** EM Segmentation: Automated WF Pipelines are created &amp;lt;br&amp;gt;&lt;br /&gt;
*** Flexible atlas selection (Pediatric, etc) feature added&lt;br /&gt;
*** Workflows implemented for EM Segmenter 3.6.2 and 3.6.3 (1st Qtr 2011 release)&lt;br /&gt;
&lt;br /&gt;
** Cardiac ablation results follow-up: Workflow for registration and ROI selection of cardiac MRI and MR Angiography &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Wrokflow and Web Services for prospective DTI tractography modules (currently written as Matlab modules at PNL) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Web Services for SPECTRE Scull stripping module&lt;br /&gt;
*** Accuracy and performance tuning&lt;br /&gt;
*** 50% completion&lt;br /&gt;
&lt;br /&gt;
** Migration Front End GUI to Slicer4/QT:&lt;br /&gt;
*** EM Segmentation&lt;br /&gt;
*** Cardiac Ablation Study&lt;br /&gt;
&lt;br /&gt;
** DICOM Uploader and Desktop Browser for XNat Image repository (alpha version - tested for MGH MS Center studies, proposed to use with MI2B2 Clients and Services)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''4th Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study and EM Segmentation for Aging Study are deployed at end-user sites and actively used for research. &lt;br /&gt;
** Adopted EM Segmentation preprocessing pipeline for HIV Study: high resolution SPGR images, integration with FreeSurfer brainmask extraction outputs; integration of Slicer SPECTRE module for brainmask extraction is in progress.&lt;br /&gt;
** The following post-release upgrades had been implemented based on end-user feedback: Application Server basic controls are performed from Rich Client GUI as alternative to traditional IT administration activities. The controls are implemented on point-and-click bases and include web services and workflow application deployment and upgrades, application server start and stop as well as warning end user when the server is not accepting request.&lt;br /&gt;
** Added DICOM downloads and results uploads of PET/CT pipelines from and to XNat Repository&lt;br /&gt;
** Created Services and Workflow for Matlab Prototypes modules. Case Study: tractography for DTI images&lt;br /&gt;
** Extended XNAT integration services:&lt;br /&gt;
*** Browsing capabilities of XNat data repository from the Workflow Applications&lt;br /&gt;
*** Improved DICOM upload and download performance&lt;br /&gt;
*** Added Metadata organizing services for uploaded DICOM images: header data extraction, image snapshots creation. &lt;br /&gt;
** Started project for Rich Client GUI migration from Java desktop application to build into SLicer4 QT modules. This affects mostly front-end GUI and has the following approaches: distribution with the Slicer4, end-user will select desired workflow application from Slicer4 menu while QT-written modules provide with the same functionality as Java Rich Clients. Case Study for the Migration process: registration suite for longitudinal studies that include multi-modality images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* '''3d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Concentrated on building downloadable workflow applications that could run both in desktop (new) and server environment, and that require minimum IT administrative resources. The desktop deployment is in compliance with Slicer3 general deployment concept.&lt;br /&gt;
*** The following use case scenario had been chosen: PET/CT image processing for longitudinal studies, EM Segmentation for longitudinal Aging Study.&lt;br /&gt;
** Released workflow application for PET/CT image processing for longitudinal studies. Provided end users with training and documentation.&lt;br /&gt;
*** The PET/CT processing workflow was designed to be a general application used whenever both structural patterns and metabolic activities are within the research scope. &lt;br /&gt;
*** The desktop version is tuned to use minimal computer resources, so the automates processing instances do not interfere with human activities. Automated activities may include, for example, registration and PET scan's standard uptake values computing, and manual human activities may include image cropping, quality control, and labeling voxels of interest.&lt;br /&gt;
** Core services and EM Segmentation preprocessing workflow was build for retrospective Aging Study. Tuned the Slicer3 webservices for processing low grade images acquired in mid 90s. Entire workflow is implemented with Slicer3 only modules and can be deployed locally and on the servers. Usage of Service Oriented Architecture (SOA) as a core technological approach allowed reusing most of the web services that had been build for PET/CT project. &lt;br /&gt;
** Continued embedding Slicer3 application and modules into previously released processing pipelines: replaced MIPAV with Slicer3 GUI for lesion assessment step in the multi-center Pediatric MS Cohort image processing &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''2d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Completed Social Cognition Workflow Implementation. This includes EM Segmetnation pre- and post-processing pipelines, data tracking, and integration with 3d party image processing utilities, as well as processing results acquired manually with Slicer GUI.  &lt;br /&gt;
** Multi-modality image registration and ROI selection/alignment workflow for longitudinal studies. &lt;br /&gt;
*** Use case: PET/CT image processing for longitudinal studies. &lt;br /&gt;
*** Build portable library of Slicer modules as web services and workflow that are deployed and run on a end-users' worksatations without utilization of SPL and other servers. The web services include novel Slicer3 modules, such as BRAINSFit and BRAINSResamle &lt;br /&gt;
*** Started working with Slicer3 developers on Slicer 3.8 GUI wizard to communicate with workflow instances.&lt;br /&gt;
** Participated at NA-MIC Summer 2010 Project Week: [[Summer_project_week_2010_Workflows_SOA]]&lt;br /&gt;
&lt;br /&gt;
=Progress=&lt;br /&gt;
&lt;br /&gt;
* May 20, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General / PETCT V1.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Hemispheres EM Segmentation - adjusted for required label lookup table&lt;br /&gt;
* Use cases added for EM Segmenter General Project: http://www.slicer.org/slicerWiki/index.php/EMSegmenter-Tasks#EMSegmenter_use_cases&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SPECTRE Scull Stripping&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* The new version to be tested on coming week (After PETCT MRI processing migrated to Hemispheres scenario )&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* May 13, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General / PETCT V1.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Hemispheres EM Segmentation - technically works with labal values hardcoded in Slicer EM Segmenter - need to add manual label value edition step&lt;br /&gt;
* PETCT WF Cut for Java GUI (Pending Hemispheres label update completion). Next release will be in QT4.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* May 6, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (QA of EM Segmenter module, work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* April 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Open Discussion for Packaging WF QT Modules as Slicer4 extensions (waiting for SOPs)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review supported projects http://wiki.na-mic.org/Wiki/index.php/File:SlicerWF_EMSegmentProjectsReview.zip &lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (required by Study)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Slicer Modules General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Standardizing Crop Volumes Output (with A. Fedorov's module). Review for required updates of existing product (PET/CT, CARMA)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Open Discussion for Packaging WF QT Modules as Slicer4 extensions (waiting for SOPs)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review supported projects http://wiki.na-mic.org/Wiki/index.php/File:SlicerWF_EMSegmentProjectsReview.zip &lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (required by Study)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Slicer Modules General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Standardizing Crop Volumes Output (with A. Fedorov's module)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 22, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Beta release ready. Demo Location: http://cni29.bwh.harvard.edu/SlicerWFDemo/index.php&lt;br /&gt;
* TODO: Tutorial. Original inputs copy/renaming&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 15, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Adding App server auto-config features&lt;br /&gt;
* Finalizing the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 08, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Second release beta build tested on cosutmer side &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review registration quality (with Dr. Meier). Angiography images' Resampling tuned. &lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 01, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the second release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
XNat Integration&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* (Java) GUI for Project Browsing and DICOM Series Upload. Post-upload DICOM processing tested and debugged&amp;lt;br&amp;gt;&lt;br /&gt;
* Ready for integration with mi2b2 client.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Migrated to Latest Slicer 3.6.3 stable release: only the Input scene had to be updated, the API remained the same&lt;br /&gt;
* Tested EM Segmenter with CMTK4Slicer extension - processing takes to much time on Linux_64bit machine, rolled back to BRAINSFit registration. When used on Mac OS X build, the Slicer could not start (bug report 1126).&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SPECTRE Scull Stripping:&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Testes for various use cases: the module is extremely sensitive to T1 MRI quality (does not work for most MRIs from PET/CT project&lt;br /&gt;
* TODO next week: check for FLAIR images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Slicer4 QT GUI and Cropping activity in progress.&amp;lt;br&amp;gt;&lt;br /&gt;
* Tried direct MRA to MRA registration option: resampling with LMRI registration transforms works better.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Extra VOI labels revised&lt;br /&gt;
* Debugging of SUV results' renormalization step&lt;br /&gt;
* TODO: ICC extraction / whole brain total uptake computing; EM Segmentation for R_WM, L_WM SUV computing and BPH estimation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SCULL STRIPPING/SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Installed and tested CLI option on Linux_64bit platform&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Workflow interruption before BSPline registraton: BPEL Module completed. Slicer4 QT GUI and Cropping activity in prorgess.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Implemented and Tested with end-users proposed changes: denormalization of SUV results, adding more VOI labels, added FLAIR MRI in addition to T1s for VOI drawing&lt;br /&gt;
* Tested manual ICC extraction using PET scans: works satisfactory with island removal and cropping followed by threshold level labeling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4&lt;br /&gt;
* Change proposed: interrupt workflow after affine registration and have user crop the VOI. This is to prevent excessive deformations for BSpline registration and resampling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4. User has option to choose the atlas that fits better for the given subject (NOTE: hardcoding must be rewritten for atlas linking)&lt;br /&gt;
* PETCT test - the problem is that T1s are low resolution and with contrast. Proposed using T1s without contrast&lt;br /&gt;
* PETCT change request: users wants to compute SUV for entire ICC. Had demo how to segment brainmask/ICC using PET scan. The derived brainmask label can be used for SUV computation.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - cmpleted&lt;br /&gt;
* Sample cases run - excessive deformation after BSpline registration hase&lt;br /&gt;
* Next week plan - pull tuning controls to front-end of pipeline API, start working of QT module for CARMA registration&lt;br /&gt;
* May consider other than BRAINSFit registration modules&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Design plan for change request: more VOI labels, add FLAIR in addition to T1 for VOI drawing, T1s segmentation&lt;br /&gt;
* Tested segmentation for sample cases - artifacts from poor quality MRIs lead to exclusion of parts of ICC from segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Completed troubleshooting of EMSegmenter module calling from Java (need TCL libs to be pulled from Slicer environment)&lt;br /&gt;
* Tested EMSegmenter autoruns for HIV and Pediatric MS patiens. Work as expected, subject to improvement of PED MS case segmentation by building better skull/neck/air atalses&lt;br /&gt;
* Suggested usage of two subsets of atalases: with and without neck. The Subject MRIs have to be cropped accordingly or best fit atlas has to be selected&lt;br /&gt;
* Made no-neck cropped atlas collection for default EMSegmenter scenario&lt;br /&gt;
* Tested with PET/CT study MRI cases - see above &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - in progress&lt;br /&gt;
* Next week goal - have back end processing ready&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Longitudinal Study&lt;br /&gt;
* Added MRI registration to the pipeline&lt;br /&gt;
* Troubleshooting of complex XML schema issues on Linux machines (some modules working on MAC do not work on Linux). As a workaround - did not include MRI convert and register part into base BPEL module. Used separate services (transparent for end-user)&lt;br /&gt;
* TODO next week for change request completion: explicit pixel type casting for MRI in BRAINSFit, VOI MRML scene update (currently MRI added on top of schema)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* February 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipeline for Pediatric MRI. Same scenario as for HIV Project, icbm pediatric atlases (Completed, verified)&lt;br /&gt;
* Collected NIH healthy brain development atlases: various age ranges from 4.5 to 18 yo. Converted to Slicer readable format &lt;br /&gt;
* Work on web services for the new automated EM Segmenter module (release Nov 10 - current). Verified task completion both for adult and pediatric images. Discussed tuning parameters for work load balance on workstations.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Started working on MRI registration to the reference CT scans. &lt;br /&gt;
* Design specs for optional White Matter segmentation for SUV computing.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* February 4, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipelines for Pediatric MRI (in progress)&lt;br /&gt;
* Adapting Pediatric T1 atlases for &amp;quot;Human Brain&amp;quot; build-in EM Segmentation wizard (in progress)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 28, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Verifying EM Segmenter module for latest builds and HIV/PED MS Studies (report pending)&lt;br /&gt;
* Work with SPECTRE module developers with pediatric MRI brainmask extraction&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* January 21, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Compiling plan for WF FrontEnd GUI migration to Slicer4/QT Widgets&lt;br /&gt;
* Preparing for annual progress report&lt;br /&gt;
&lt;br /&gt;
* January 14, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI: Integrated into the Slicer4 as Slicelet (or thin Client)&lt;br /&gt;
* Participation at AHM-2011, discussing integration of SPECTRE module and updated approach to EM-Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA&lt;br /&gt;
&lt;br /&gt;
* January 7, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* HIV project workflow delivered. Major additions relate to user convenience: &lt;br /&gt;
- Project-specific parameter settings, importing T1s and brainmasks from FreeSurfer outputs with conversion to NIFTI, resampling brainmask to original scans and automatied subject addition.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Follow up with end user: need to add MRI scans, if available, addition and registration to CT in order to ease VOI drawings.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
 &lt;br /&gt;
* December 31, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Follow-up with user Experience for AGING Study Segmentation (Positive feedback)&lt;br /&gt;
* Target date for HIV project delivery - next week&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Self-training for QT widget development&amp;lt;br&amp;gt;&lt;br /&gt;
* Outlined Workflow Rich Clients migration strategy from Java to QT/Slicer4:&amp;lt;br&amp;gt;&lt;br /&gt;
** Use Java Stubs (similar to SPECTRE integration) or file binding for envocation of workflow pipelines. (See SOAP remark below)&lt;br /&gt;
** Direct Web Servisec calls must be wrapped into REST protocol. The reason: NON-commerchial QT kit does not include SOAP protocol for web servises.&lt;br /&gt;
** The GUI will be implemented as page widget or QT dialog GUI forms called from within Slicer4.&lt;br /&gt;
** Communications between Slicer4 and WF GUI will be set via child-parent and signal-slot relations&lt;br /&gt;
* Worked on a Prototype for Basic EM Segmentation QT widget (70% complete). Will work on integrtion with SLicer4 during the AHM-2010&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
XNAT Integration&lt;br /&gt;
* Debugged XNAT RESTFul API usage for uplaoding DICOM series followed by header data extraction and image snapshots creation&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Added compensation for failed atlas registration (subject for old poor quality pseudo-T1 images): blank probability maps are created in case of failure.&lt;br /&gt;
* Data preparation module for FreeSurfer data import near completion. Expected time for deployment at end-users workstations - first week of January&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Discussed strategy for EM Segmentation pipeline solutions collection (K. Pohl, R. Kikinis)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* RE-using the same core workflow as for 1-channel EM Segmentation of AGING STUDY cases&lt;br /&gt;
* Added data input preparation module: ICC label mask preparation and skull-stripping based on FreeSurfer brainmask output volume.&lt;br /&gt;
* Two-channel EM segmentation pipeline (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE / GENERAL Development &amp;lt;br&amp;gt;&lt;br /&gt;
* Worked on plans for migrating fro rich workflow Java clients to embedded workflow windows inside the Slicer.&amp;lt;br&amp;gt;&lt;br /&gt;
The embedded workflow management clients are to be implemented with QT/PyQT toolkits&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
INTEGRATION WITH XNAT:&amp;lt;br&amp;gt;&lt;br /&gt;
* Automated DICOM series upload with triggering DICOM headers parsing at XNat site (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress. &lt;br /&gt;
- Results upload to XNat (Completed) &amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat based on user's input (Project + Subject + PET or CT session / scan) (Completed)&amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat - perfomance boosting solution for downloads found , web services services are created, relinking for the client side in progress &amp;lt;br&amp;gt;&lt;br /&gt;
- Xnat querying for subjects and automated subject addition into the workflow (In Progress) &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-segmentation module added for auto correction of segmentation results. Particularly - relabeling CSF voxels segmented as Air inside the intracranial cavity. This was requested by end-users after processing images with zero-signals in CSF voxels &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting automated dual-echo DICOM images conversion and split into two NRRD volumes&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT / EM Segmentation pipeline:&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting memory allocation issues for scull-stripping module SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
COPD Project:&amp;lt;br&amp;gt;&lt;br /&gt;
* Benchmark test for accelerated DICOM downloads from XNat (remoote XNat Central server): we can handle at least 6 cases (4 CT scans in each) per hour, which is compatible with current workload quotes on SPL cluster processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* December 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Deployed Version 1. &amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Test project chosen as a closest match to registration scenario: Pediatric MS Cases from MGH - requires periodic image preview for different &lt;br /&gt;
modalities taken from vaious time points. Label maps for VOIs resampling is also required.&lt;br /&gt;
&lt;br /&gt;
* November 26, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user. Version 1 is complete&amp;lt;br&amp;gt;&lt;br /&gt;
* Started working on integration with XNat&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on input data organizing modules&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 19, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user (70% done)&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Universal Registration Workflow for Longitudinal Studies - design specs in progress&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 12, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Minor tuning to EM Segmentation template as of users' feedback&lt;br /&gt;
* Users started using the workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed input data conversion from Genesis to Slicer native or NIFTI format. Our help may be needed in input data organizing.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Tuned application according to co-laborators (PNL) needs&amp;lt;br&amp;gt;&lt;br /&gt;
* The webservices and BPEL workflow application are tested ready to accept computation requests from PNL case tracking system &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Discussed Universal Registration Workflow for Longitudinal Studies&lt;br /&gt;
* Started the thread about possible cooperation with Children hospital's image processing pipelines and integration with Xnat &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 5, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Webservices and workflow pilot project created and deployed on Psychiatry Neuroimaging Laboratory subnet &amp;lt;br&amp;gt;&lt;br /&gt;
* The V.1.0 deployment is scheduled for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 29, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Most of functionality is completed. Some volume statistics post processing is pending&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL EM SEGMENTATION Pipeline: &amp;lt;br&amp;gt;&lt;br /&gt;
* The SPECTRE scull stripping module. Started integration into EMS workflow. Made some test runs from Slicer GUI&amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Identified as a candidate for Workflow Application&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 22, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* All back-end functionality are implemented&amp;lt;br&amp;gt;&lt;br /&gt;
* EM Segmentation scene usability is confirmed by end-user&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for next week: add Label Statistics computation for CSF/Brain/ICC &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 15, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* The latest (October) builds of Slicer 3.6.2 produced acceptable results. This was verified by the target users. The EM Segmentation will be performed on Slicer 3.6.2 or later&amp;lt;br&amp;gt;&lt;br /&gt;
* The new Web services had been created and added to the pipeline as optional processing steps: Biasfield correction (implement novel N2ITKBiasFieldCorrection module) and Volume's scalar datatype casting (as workaround for Biasfield correction module not preserving image scalar datatype - the bug is filed) &amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed the Front-End GUI design with target users. The design pattern is taken from the PETCT project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 8, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-deployment support. Tuned CT registration as of user's feedback.&lt;br /&gt;
* Adapting to the Single Slicer build: Slicer 3.6.2. Found label duplicates in the label lookup table - will ask user if it's tolerable. Waiting for the Slicer 3.6.2 build that contains all required modules. Rolling back label tag appending code for SUVs - the latest Slicer build appends the tags.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Resumed development. The priorities are set for usage of Slicer 3.6.2 - subject for EM Segmentation scene tuning. Continued coding for Scene creation for Slicer 2.8 - as a backup option for ongoing research project.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 1, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized V1.0 release based on end-user feedback: updates relate mostly to error proofing and SUV values representation&lt;br /&gt;
* Post-deployment support. Users pre-processed first set of patients &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* September 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* System deployed and tested at End Users' site.&amp;lt;br&amp;gt;Users are trained to perform all tasks required by the workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
* Got positive feedback with suggestions on Slicer Scenes' layouts improvement and PET scans' SUV (standard uptake values) results display&lt;br /&gt;
* Two distribution packages are assembled: Lunix and MAC OS versions. The difference in two packages is in specific Slicer3.6/3.7 builds - subject to Slicer Linux builds debugging.&amp;lt;br&amp;gt; As a workaround for Linux deployment - multiple Slicer builds are used to perform various tasks (registration, opening editing scenes in Slicer, SUV computing)&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for coming week - finalize V1.0 release based on end-user feedback&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Embedded SUV computations into the workflow (as system calls - will be translated into web service later)&amp;lt;br&amp;gt;&lt;br /&gt;
* Pre-release demo for end users.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Create and debug EM Segmenter scenes template for Slicer 3.6 and 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* September 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation - workflow pipeline and deployment verified&amp;lt;br&amp;gt;&lt;br /&gt;
* Tested EM Segmentation scenes within Slicer 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
* Started migration of EM Segmentation to Slicer 3.6. Discovered issues had been reported to EM Segmenter module designers &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* August 29 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation completed. Preprocessing Pipleine completed 80% (subject for input registration parameters tuning) &amp;lt;br&amp;gt;&lt;br /&gt;
* Most webservices (for registration and resampling steps) had been taken and re-used from PET/CT ROI/Longitudinal Study - showing the advantage of service-oriented software design and deployment.&lt;br /&gt;
* Continued on distribution and deployment of the service/workflow applications: on PET/CT and AGING STUDY projects.&lt;br /&gt;
&lt;br /&gt;
PEDIATRIC Multiple Sclerosis Cohort. Support of multi-center distributed processing project&amp;lt;br&amp;gt;&lt;br /&gt;
* Introduced Slicer 3.6 for the MS Lesion Assessment step performed at Mayo Clinic. Images are being transferred from image repository at BWH and automatically opened and arranged within Slicer GUI for reading.  This was replacement of Client GUI using MIPAV that stopped working on new computers at Mayo Clinic.&lt;br /&gt;
The images are being loaded via generated MRML Scenes same way as in PET/CT and AGING STUDY projects &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* August 22 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Preprocessing pipeline merge with SUV computations &amp;lt;br&amp;gt;&lt;br /&gt;
- QA for SUVs computation was performed by Wendy Plesniak for images with known uptake values. &amp;lt;br&amp;gt;&lt;br /&gt;
- Discovered that image cropping step (not related to automated registration pipeline and SUVs computing) smoothes the images by doing interpolation when used with default settings. Got suggestions from Steve Piper using Nearest-Neighbor interpolation (&amp;quot;no interpolation&amp;quot;) for a time being&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
- This is the new project candidate. Requested for the images with failed manual segmentation and/or segmentation with FreeSurfer. The EM Segmentation run showed most acceptable results on one of the problem images back in February &amp;lt;br&amp;gt;&lt;br /&gt;
- The workflow will be developed and deployed similar to PET/CT ROI Longitudinal study approach - all preprocessing steps will be done with Slicer modules, all runs will be performed on local end-user machines.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
 &lt;br /&gt;
&lt;br /&gt;
* August 15 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- First 5 cases with 3-4 time points preprocessed for SUVs computation&lt;br /&gt;
&lt;br /&gt;
* August 8 2010&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Testing of installation and operation at users' site (Performed by Wendy Plesniak)&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* July 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Delivered beta version of registration pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
- Prepared installation and user manuals &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* June 11, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Registration modules completed &amp;lt;br&amp;gt;&lt;br /&gt;
- Irregular cases registration problem solved (when whole body and brain only scans are mixed for a timepoint)&amp;lt;br&amp;gt;&lt;br /&gt;
- Live demo of case setup and registration workflow for end users. Real case with 4 timepoints used&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Coming week plans&amp;lt;br&amp;gt;&lt;br /&gt;
- Adjust workflow based on end users' feedback&amp;lt;br&amp;gt;&lt;br /&gt;
- Integration with SUVs computing for PET scans&amp;lt;br&amp;gt;&lt;br /&gt;
- GUI for workflows dispatching and data organizing&amp;lt;br&amp;gt;&lt;br /&gt;
- (TBD) Integration with 4D time series analysis Slicer module&amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
* May 28, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- Migration to the latest Slicer 3.6 release candidate &amp;lt;br&amp;gt;&lt;br /&gt;
- Added webservice for new registration module: BRAINSFit &amp;lt;br&amp;gt;&lt;br /&gt;
- Test runs for new patients with 4 timepoints' scans &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Plans for next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI &amp;lt;br&amp;gt;&lt;br /&gt;
- processing workflow demo for end user &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 21, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Pilot version of portable web services and automated workflow tested: &amp;lt;br&amp;gt;&lt;br /&gt;
Linux: workflow and visual review passed&amp;lt;br&amp;gt;&lt;br /&gt;
Stress test for 25 timepoints passed &amp;lt;br&amp;gt;&lt;br /&gt;
MAC OS: workflow passed, visual review failing when PET/CT images are loaded into GUI simultaneously (bug report submitted)&amp;lt;br&amp;gt;&lt;br /&gt;
Windows: need to adapt command line modules and workflow management system to sygwin environment&amp;lt;br&amp;gt;&lt;br /&gt;
Plans for next week: integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI&lt;br /&gt;
&lt;br /&gt;
* May 7, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Selected registration and resampling modules with more precise and stable outputs. &amp;lt;br&amp;gt;&lt;br /&gt;
Started building portable web services and automated workflow &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 30, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- manual walk through the processing steps: ROI cropping, registration/resampling, PET pharmaceutical DICOM data retention. &amp;lt;br&amp;gt;&lt;br /&gt;
- testing workflow and web services packages distribution to end-users' machines&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* April 23, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : testing various registration and re-sampling algorithms (work in progress)&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation: as of collaborators' request, run existing EM Segmentation workflow for older low resolution pseudo-T1 images. The EM Segmentation works for those images with manual sampling. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 16, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
  Social Cognition Study: started Cortical Thickness Measurement module build (bases on NA-MIC ARCTIC pipeline) &amp;lt;br&amp;gt;&lt;br /&gt;
  PET/CT ROI/Longitudinal Study Registration : Design specs, PET-to-CT images registration tests on training data. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 9, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. GUI update based on end-user experience.&amp;lt;br&amp;gt;&lt;br /&gt;
User request: automated label maps' volumes calculation (Currently possible from Slicer3 GUI)&amp;lt;br&amp;gt; &lt;br /&gt;
PET/CT ROI Project. Initial design specs discussion with end-users and co-developers&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure&lt;br /&gt;
Verification of segmentation workflow GUI: from registering new case to reviewing results&amp;lt;br&amp;gt;&lt;br /&gt;
Cross study test of segmentation workflow: MGH/MS Center data - success,  HIV Project data - some EM Segmentation scene tuning is needed &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*&lt;br /&gt;
* April 2, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. Segmentation workflow completed&amp;lt;br&amp;gt;&lt;br /&gt;
* Coming Week plans:&amp;lt;br&amp;gt;&lt;br /&gt;
- Document Segmentation Workflow. Follow up with end users &amp;lt;br&amp;gt;&lt;br /&gt;
- Start with Cortical Thickness and ROI-in-longitudinal studies workflows&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* March 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All essential processing and workflow interaction clients are ready.&amp;lt;br&amp;gt;&lt;br /&gt;
- Completed segmentation for 10 out of 50 patients. The remaining cases will be finalized upon manual lesion segmentation and QC verification of WM/GM/CSF and Deep GM segmentation's. &amp;lt;br&amp;gt;&lt;br /&gt;
- TODO next week: refine QC GUI and data tracking / progress monitoring schema. &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&amp;lt;br&amp;gt;&lt;br /&gt;
- New Slicer3 web services added: re-slicing with reference image volume, casting image scalar type &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
* March 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Segmentation maps Merging Services for GM/WM/CSF (Slicer EM Segemnter), Lesion (Slicer, Manual), and Deep GM (FreeSurfer)  &amp;lt;br&amp;gt;&lt;br /&gt;
- Deep GM segmentation pipeline adopted as optional service for Social Cognition Study (22 out of 50 cases processed) &amp;lt;br&amp;gt;&lt;br /&gt;
- (In progress) GUI client for Launching Segmentation results merging with optional Deep GM segmentation with FreeSurfer &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- Complete GUI Client for Segmentation result merging &amp;lt;br&amp;gt;&lt;br /&gt;
- Progress Monitoring services for entire Study processing: EM Segmenter Preprocessing, EM Segmentation, Lesion Segmentation (including human activities assignments), Deep GM segmentation, and results consolidation. &amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* March 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All 50 cases went through &amp;quot;basic&amp;quot; One-channel EM segmentation (GM/WM/CSF) &amp;lt;br&amp;gt;&lt;br /&gt;
- Basic pipeline start-up command line client created: user has two options - request brainmask extraction or provide with previously extracted brainmask for a given subject &amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison of GM/WN/CSF performed for Slicer EM Segmenter and FreeSurfer recon-all (used with default settings). &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmenter provides more accurate output &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmentation pipeline runs faster (40 minutes vs 12 hrs when no brainmask extraction requested) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO:&amp;lt;br&amp;gt;&lt;br /&gt;
- merging modules for automatic 1-channel EM segmentation and manual lesion segmentation &amp;lt;br&amp;gt;&lt;br /&gt;
- Emerge Cortical Thickness pipeline project: use NAC ARCTIC processing steps and modules &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Selected stable EM Segmentation scenario: White Matter, Gray Matter, and Cerebrospinal Fluid &amp;lt;br&amp;gt;&lt;br /&gt;
- First 16 cases are segmented for selected scenario. Nine more cases are preprocessed for EM Segmentation.&amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison to segmentation with FreeSurfer showed better accuracy for Slicer2 EMSegmenter &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure &amp;lt;br&amp;gt;&lt;br /&gt;
- Three prerpcocessed cases failed during volume ICC masking with in-house build utility. Evaluated switching to Slicer3 Mask and island removing modules.&amp;lt;br&amp;gt;&lt;br /&gt;
- Initial design specs discussion for cortical thickness measurement pipeline. ARCTIC pipeline selected. ARCTIC preprocessing steps signifficantly overlap with EM Segmentation preprocessing workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
  &lt;br /&gt;
* February 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: &amp;lt;br&amp;gt;&lt;br /&gt;
A) parameters tuning for EM Segmenter itself (work with EM Segmenter developer), template scenes creation &amp;lt;br&amp;gt;&lt;br /&gt;
B) update preprocessing pipeline - deep gray matter atlases included &amp;lt;br&amp;gt;&lt;br /&gt;
C) test and debug preprocesing pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
D) identified missing modules: atlas autocalibration for EM Segmentation scene, Island removal for ICC mask&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- Review currently deployed modules. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: reviewed firts seven subjects' outputs, added volume orientation module into pipeline (prevents ICBM atlas linear registration failures)&amp;lt;br&amp;gt;&lt;br /&gt;
- Fused ICC(brainmask) extraction module with EM Segmenter preprocessing. Three scenarious implemented: start with pre-extracted ICC mask (longitudinal studies case), run with ICC ectration, run with ICC extraction AND ICC correction before ICBM atlas preporcessing. &amp;lt;br&amp;gt;&lt;br /&gt;
- Completion of Human activities GUI (QC, ICC Correction) planned for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: Volume Orientation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: automated preprocessing pipeline for Slicer2 EM Segmenter test version deployed. Seven cases pre-processed.&lt;br /&gt;
- PET Quantitative measurements: Preliminary design specs discussion.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: BSplineRegistration (for non-linear registration), ResampleVolume2 (for atlases resampling based on image atlase templates registration). Local and Network runs are implemented, Cluster/GridWizard implementation pending.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Slicer EM Segmenter module: preprocessing design for Slicer2 EM Segmenter&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Adapting for Slicer2 EM Segmenter (mostly from pipelines and services for previous projects)&lt;br /&gt;
  -- Integration with FreeSurfer modules for bisafield correction, brainmask extraction, and linear registration of ICBM atlases&lt;br /&gt;
  -- Preprocessing updates for non-linear registration of ICBM atlases with Slicer2 (image re-orientation service designed)&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 29, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- EM Segmentaton pipeline: preprocessing results are being transferred to XNat (anonymized data, Central XNat) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Slicer EM Segmenter module: discussed agenda and scheduled a work meeting for Social Cognition Study image segmentation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Testing stage, 95% completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- SPL XNat server: verified data exchange via RESTfull web services.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 22, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Follow up with White Matter Lesion Segmenter and Scull Stripping Modules developers: Work in Progress&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Work in Progress, 60%+ completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Discussed SPINE image repository migration to XNat&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 15, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. &lt;br /&gt;
- Social Cognition Study: &lt;br /&gt;
Work-in-progress on intermediate (reconstruction) and results (resources) data storage at XNat.&lt;br /&gt;
&amp;lt;br&amp;gt;Reviewing and preparation more cases for EM Segmentor (Slicer 3.5) tuning.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* NA-MIC Project Week&lt;br /&gt;
Selecting candidate Slicer modules for other than Lesion EM Segmentation topics of Social Cognition study: Withe Matter Lesion Segmenter (UNC), Scull Stripping utility from UIOWA.&lt;br /&gt;
Reviewing issues of currently used Scull Stripping Slicer Extension and Slicer 3.5 EM Segmenter.&lt;br /&gt;
&amp;lt;br&amp;gt;XNat Data organizing training&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 1, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Preparation of Demo for NA-MIC work week: &lt;br /&gt;
- COPD Study. Added Remote pipepline start interface (represents real world scenario where Xnat repository, Processing modules and User are at different sites)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
- EM Segmentation. Added human activities steps to the workflow: ICC (brainmask) correction and EM Segmantation scena load per se.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 25, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Pilot workflow pipeline for EM Segmentation (all steps except user-activity step: ICC correction assignment and tracking)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 18, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Build and tested web services for EM Segmentation image preprocessing: DICOM-to-NRRD conversion, registration, skull stripping, image masking.&lt;br /&gt;
Started building workflow pipeline (subject to finish first version next week)&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Started Collecting Library of Slicer Build number vs. functional modules and extensions.&lt;br /&gt;
Plan for NAMIC project week: scheduled meetings for XNat data customization, Skull-stripping modules tuning, identified Social Cognition study cases that fail EM Segmentation processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 11, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Updating and verification of EM Segmentation Scenario&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Projects:ARRA:SlicerWF:UseCaseScenarios#Usecase_MS_lesion_Assessment&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Familiarizing with Slicer3.4/5 Modules required for implementation of EM Segmentation Scenario. Participation in debugging and/or usage tuning of Dicom Conversion, Registration, Skull Stripping, Masking, and Image Casting modules. &lt;br /&gt;
&lt;br /&gt;
* December 4, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Slicer3.4's EM Segmentation and Visual QC as part of image processing pipeline for Social Cognition Study for MS Patients.&lt;br /&gt;
Project emerged. EM Segmentation template creation debugged.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
Emphysema Measurements (COPD Study) - workflow stability and scalability test.&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 27, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Emphysema Measurements (COPD Study).&lt;br /&gt;
Added compensation for long running calculations and time-outs to the main computing pipeline.&lt;br /&gt;
Visual QC (work in progress)&lt;br /&gt;
** Infrastructure&lt;br /&gt;
XNat data structure customization, metadata storage, results consolidation: new feature request list creation (work in progress)&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 13, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
*** Pilot system for whole processing cycle for Emphysema Measurements (COPD Study) including the following:&lt;br /&gt;
Web query for CT session file list download&lt;br /&gt;
Pilot user interface for submitting the file list and starting processing pipeline&lt;br /&gt;
Notification about processing steps and failures&lt;br /&gt;
Upload results to XNat repository (at this stage results are uploaded into same folder where original scans are(*))&lt;br /&gt;
*** Immediate Plans&lt;br /&gt;
Complete Visual QC module&lt;br /&gt;
Design and implement meta-data transfer to XNat (including processing details and MRML files for loading images into the 3D Slicer)&lt;br /&gt;
&lt;br /&gt;
(*)Customization of results storage&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 6, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Tuned and debugged multiple subjects processing for: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat.&lt;br /&gt;
***Started working on quality control embedding into the above scenario. Plan to complete and video-record demo next week.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***Published general Product Integration scenario flow chart to collaborators' community. Discussion is open and in progress&lt;br /&gt;
&lt;br /&gt;
* October 30, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Piloted and tested the sequence: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat(1).&lt;br /&gt;
***Performance test of overall cycle: data transfer from remote serve is a bottleneck as expected&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data browsing features reviewed.&lt;br /&gt;
(1) Not automated yet&lt;br /&gt;
* October 23, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Defined COPD processing scenario with interoperability between Xnat, 3D Slicer Command Modules, Workflow, and Gridwizard Enterprise.&lt;br /&gt;
***Pilot version of Emphysema Measurements workflow pipeline deployed.&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data transfer features reviewed. Use account at XNat Central during learning curve.&lt;br /&gt;
***Feasibility test of 3D Slicer fiducials module for ROI highlights during QC and manual image processing activities. &lt;br /&gt;
* October 16, 2009&lt;br /&gt;
**Lung CT Scans Processing. Pilot project emerged. GenerateEmphysemaMeasurements module deployed as a webservice that submits jobs to computational cluster.&lt;br /&gt;
**EM Segmentation. Familiarized with GUI steps. Started working on automation steps outlining&lt;br /&gt;
**3D Slicer and XNat interaction. Got an overview from Wendy Plesniak.&lt;br /&gt;
* October 1 - 7, 2009&lt;br /&gt;
**Selected two first priority Projects: EM Segmentation of brain MRI images; Lung CT Scans Processing (COPD Study)&lt;br /&gt;
**Got initial outline of user requirements and design specs&lt;/div&gt;</summary>
		<author><name>Azaitsev</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=67272</id>
		<title>Projects:ARRA:SlicerWF</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=67272"/>
		<updated>2011-05-23T13:01:17Z</updated>

		<summary type="html">&lt;p&gt;Azaitsev: /* Progress */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Projects:ARRASuplements|Back to Slicer ARRA home page]]&lt;br /&gt;
= Aim =&lt;br /&gt;
Supplement 3D Slicer and Extensible Neuroimaging Archive Toolkit (XNAT) with workflow management system. Provide integration and interoperability between 3D Slicer, XNAT Services and 3-rd party image processing applications and high performance computing systems. Implement it as within currently developed Structural Planning and Implementation in Neurological Exploration (SPINE) System.&lt;br /&gt;
&lt;br /&gt;
= SPINE Project Documentation =&lt;br /&gt;
[http://cni.bwh.harvard.edu/projects/spine/index.html SPINE Docs]&lt;br /&gt;
&lt;br /&gt;
= Presentations =&lt;br /&gt;
* Segmentation Workflow. PECS University Social Cognition Study.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:SlicerWF_NAC_PECS_Workflow.pdf]]&lt;br /&gt;
* EAB10_ARRA Annual Progress Report Slides.&amp;lt;br&amp;gt;&lt;br /&gt;
[[media:EAB10_ARRA_WF_2011_Zaitsev.ppt | Service Oriented Solutions for 3D Slicer. EAB10_ARRA_WF_2011. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:EAB10_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:NAMIC_ARRA_WF_2011_Zaitsev.ppt  | NAMIC Annual Report 04/2010-03/2011. NAMIC_ARRA_WF_2011_Zaitsev. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:NAMIC_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:Slicer_WF_Slicer4CARMAWorkflow.ppt  | CARMA Workflow. Cardiac Ablation Followup. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:Slicer_WF_Slicer4CARMAWorkflow.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* CARMA Project Beta release Demo Location: http://cni29.bwh.harvard.edu/SlicerWFDemo/index.php&lt;br /&gt;
&lt;br /&gt;
* Segmentation Workflows: Screenshots, scans' and study description : [[File:SlicerWF_EMSegmentProjectsReview.zip]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
= All Hands Meeting Pages =&lt;br /&gt;
* Salt Lake City 2011 Winter [http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA SLC_2011_WorkFlow]&lt;br /&gt;
* MIT 2010 Summer [http://wiki.na-mic.org/Wiki/index.php/Summer_project_week_2010_Workflows_SOA MIT_2010_WorkFlow]&lt;br /&gt;
&lt;br /&gt;
= Research Plan =&lt;br /&gt;
*Create a stand-alone SPINE desktop agent with fully functional data exchange and communication mechanisms towards 3D Slicer and XNAT.&lt;br /&gt;
*Develop Service Oriented Architecture (SOA) SPINE System that will include 3D Slicer image processing modules deployed as web services as well as a workflow management system to orchestrate interaction between 3D Slicer, XNAT, and 3-rd party tools.&lt;br /&gt;
*Implement two-way control and communications between 3D Slicer and SPINE modules.&lt;br /&gt;
*Adapt SPINE System for cluster and grid computing scenarios.&lt;br /&gt;
*Provide with workflow and 3D Slicer web service wrappers editing tools.&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:UseCaseScenarios| Use Case scenarios]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PETCTWorkflow| PETCTWorkflow]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:AgingStudySegmentation| AgingStudySegmentation]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:TwoTensorTractography| TwoTensorTractography]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:LongitudinalMultimodalityRegistrationSuite| LongitudinalMultimodalityRegistrationSuite]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:MigrationJavaClients2QT| MigrationJavaClients2QT]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PediatricMSSegmentation| PediatricMSSegmentation]]&lt;br /&gt;
*[[DBP3:Utah:RegSegPipeline| MRI-based study and treatment of atrial fibrillation]]&lt;br /&gt;
&lt;br /&gt;
= Application Server / Workflow Engine Downloads =&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:WFEngineDownloads| Download Links]]&lt;br /&gt;
&lt;br /&gt;
=Key Personnel=&lt;br /&gt;
* Charles Gutmann, MD., 4%,  9-17-2009 through 9-16-2011&lt;br /&gt;
* Alexander Zaitsev, Ph.D., 75%, 9-17-2009 through 9-16-2011 &lt;br /&gt;
&lt;br /&gt;
=Annual Progress Statements =&lt;br /&gt;
'''2010-11''' &amp;lt;br&amp;gt;&lt;br /&gt;
The  April 2011 – March 2011 period was devoted on developing portable workflow solutions that can be deployed on end-users' workstations or notebooks with minimal or no system administration activities. This is in contrast to the server-side deployment. The following scenarios had been deployed and used for actual projects that require the following types of workflows: PET/CT registration and computation of biomarker driven brain physiological activities, Brain MRI Images segmentation,  MRI and MRI Angiography images pre-processing for cardiac ablation outcome estimation. Some  workflows (like EM Segmentation) had been utilizing various scenarios, some research projects  (like evaluation of chemotherapy outcome) require two types of workflows to assess physiological and structural changes. Starting from the 4th Quarter of 2011, the migration project had been emerged in order to embed Workflow GUIs into newly developed Slicer4 Suite. The existing rich client Java GUI applications are being re-written as C++/QT Sliceletts units, new modules (such as cardiac ablation project support) are had been written from scratch. The latter are being deployed from the Slicer4 GUI and act at a liaison between Slicer4 and Application Server containing  workflow and Slicer modules deployed as services. The feedback from the end users indicates that Workflow approach for the complex processing improves productivity, aids to the processing standardization and contributes to the overall experience using 3D Slicer&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
=Quarterly Progress=&lt;br /&gt;
&lt;br /&gt;
* NAMIC Annual Progress Slides (April 2010 - March 2011):&lt;br /&gt;
&lt;br /&gt;
* '''1st Qtr, 2011''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study: Second release is under testing by end-users. &lt;br /&gt;
*** Added MRI registration to aid ROI drawing on PET scans&lt;br /&gt;
*** Improved SUV results reporting and added flexibility to update ROI lookup table&lt;br /&gt;
*** Automated EM Segmentation of MRI images for computing SUVs for white matter, CSF, and whole brain (80% completion)&lt;br /&gt;
*** Integration with SPECTRE scull stripping module (70% completion) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** EM Segmentation: Automated WF Pipelines are created &amp;lt;br&amp;gt;&lt;br /&gt;
*** Flexible atlas selection (Pediatric, etc) feature added&lt;br /&gt;
*** Workflows implemented for EM Segmenter 3.6.2 and 3.6.3 (1st Qtr 2011 release)&lt;br /&gt;
&lt;br /&gt;
** Cardiac ablation results follow-up: Workflow for registration and ROI selection of cardiac MRI and MR Angiography &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Wrokflow and Web Services for prospective DTI tractography modules (currently written as Matlab modules at PNL) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Web Services for SPECTRE Scull stripping module&lt;br /&gt;
*** Accuracy and performance tuning&lt;br /&gt;
*** 50% completion&lt;br /&gt;
&lt;br /&gt;
** Migration Front End GUI to Slicer4/QT:&lt;br /&gt;
*** EM Segmentation&lt;br /&gt;
*** Cardiac Ablation Study&lt;br /&gt;
&lt;br /&gt;
** DICOM Uploader and Desktop Browser for XNat Image repository (alpha version - tested for MGH MS Center studies, proposed to use with MI2B2 Clients and Services)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''4th Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study and EM Segmentation for Aging Study are deployed at end-user sites and actively used for research. &lt;br /&gt;
** Adopted EM Segmentation preprocessing pipeline for HIV Study: high resolution SPGR images, integration with FreeSurfer brainmask extraction outputs; integration of Slicer SPECTRE module for brainmask extraction is in progress.&lt;br /&gt;
** The following post-release upgrades had been implemented based on end-user feedback: Application Server basic controls are performed from Rich Client GUI as alternative to traditional IT administration activities. The controls are implemented on point-and-click bases and include web services and workflow application deployment and upgrades, application server start and stop as well as warning end user when the server is not accepting request.&lt;br /&gt;
** Added DICOM downloads and results uploads of PET/CT pipelines from and to XNat Repository&lt;br /&gt;
** Created Services and Workflow for Matlab Prototypes modules. Case Study: tractography for DTI images&lt;br /&gt;
** Extended XNAT integration services:&lt;br /&gt;
*** Browsing capabilities of XNat data repository from the Workflow Applications&lt;br /&gt;
*** Improved DICOM upload and download performance&lt;br /&gt;
*** Added Metadata organizing services for uploaded DICOM images: header data extraction, image snapshots creation. &lt;br /&gt;
** Started project for Rich Client GUI migration from Java desktop application to build into SLicer4 QT modules. This affects mostly front-end GUI and has the following approaches: distribution with the Slicer4, end-user will select desired workflow application from Slicer4 menu while QT-written modules provide with the same functionality as Java Rich Clients. Case Study for the Migration process: registration suite for longitudinal studies that include multi-modality images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* '''3d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Concentrated on building downloadable workflow applications that could run both in desktop (new) and server environment, and that require minimum IT administrative resources. The desktop deployment is in compliance with Slicer3 general deployment concept.&lt;br /&gt;
*** The following use case scenario had been chosen: PET/CT image processing for longitudinal studies, EM Segmentation for longitudinal Aging Study.&lt;br /&gt;
** Released workflow application for PET/CT image processing for longitudinal studies. Provided end users with training and documentation.&lt;br /&gt;
*** The PET/CT processing workflow was designed to be a general application used whenever both structural patterns and metabolic activities are within the research scope. &lt;br /&gt;
*** The desktop version is tuned to use minimal computer resources, so the automates processing instances do not interfere with human activities. Automated activities may include, for example, registration and PET scan's standard uptake values computing, and manual human activities may include image cropping, quality control, and labeling voxels of interest.&lt;br /&gt;
** Core services and EM Segmentation preprocessing workflow was build for retrospective Aging Study. Tuned the Slicer3 webservices for processing low grade images acquired in mid 90s. Entire workflow is implemented with Slicer3 only modules and can be deployed locally and on the servers. Usage of Service Oriented Architecture (SOA) as a core technological approach allowed reusing most of the web services that had been build for PET/CT project. &lt;br /&gt;
** Continued embedding Slicer3 application and modules into previously released processing pipelines: replaced MIPAV with Slicer3 GUI for lesion assessment step in the multi-center Pediatric MS Cohort image processing &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''2d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Completed Social Cognition Workflow Implementation. This includes EM Segmetnation pre- and post-processing pipelines, data tracking, and integration with 3d party image processing utilities, as well as processing results acquired manually with Slicer GUI.  &lt;br /&gt;
** Multi-modality image registration and ROI selection/alignment workflow for longitudinal studies. &lt;br /&gt;
*** Use case: PET/CT image processing for longitudinal studies. &lt;br /&gt;
*** Build portable library of Slicer modules as web services and workflow that are deployed and run on a end-users' worksatations without utilization of SPL and other servers. The web services include novel Slicer3 modules, such as BRAINSFit and BRAINSResamle &lt;br /&gt;
*** Started working with Slicer3 developers on Slicer 3.8 GUI wizard to communicate with workflow instances.&lt;br /&gt;
** Participated at NA-MIC Summer 2010 Project Week: [[Summer_project_week_2010_Workflows_SOA]]&lt;br /&gt;
&lt;br /&gt;
=Progress=&lt;br /&gt;
&lt;br /&gt;
* May 20, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General / PETCT V1.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Hemispheres EM Segmentation - adjusted for required label lookup table&lt;br /&gt;
* Use cases added for EM Segmenter General Project: http://www.slicer.org/slicerWiki/index.php/EMSegmenter-Tasks#EMSegmenter_use_cases&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SPECTRE Scull Stripping&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* The new version to be tested on coming week&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* May 13, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General / PETCT V1.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Hemispheres EM Segmentation - technically works with labal values hardcoded in Slicer EM Segmenter - need to add manual label value edition step&lt;br /&gt;
* PETCT WF Cut for Java GUI (Pending Hemispheres label update completion). Next release will be in QT4.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* May 6, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (QA of EM Segmenter module, work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* April 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Open Discussion for Packaging WF QT Modules as Slicer4 extensions (waiting for SOPs)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review supported projects http://wiki.na-mic.org/Wiki/index.php/File:SlicerWF_EMSegmentProjectsReview.zip &lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (required by Study)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Slicer Modules General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Standardizing Crop Volumes Output (with A. Fedorov's module). Review for required updates of existing product (PET/CT, CARMA)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Open Discussion for Packaging WF QT Modules as Slicer4 extensions (waiting for SOPs)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review supported projects http://wiki.na-mic.org/Wiki/index.php/File:SlicerWF_EMSegmentProjectsReview.zip &lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (required by Study)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Slicer Modules General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Standardizing Crop Volumes Output (with A. Fedorov's module)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 22, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Beta release ready. Demo Location: http://cni29.bwh.harvard.edu/SlicerWFDemo/index.php&lt;br /&gt;
* TODO: Tutorial. Original inputs copy/renaming&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 15, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Adding App server auto-config features&lt;br /&gt;
* Finalizing the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 08, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Second release beta build tested on cosutmer side &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review registration quality (with Dr. Meier). Angiography images' Resampling tuned. &lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 01, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the second release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
XNat Integration&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* (Java) GUI for Project Browsing and DICOM Series Upload. Post-upload DICOM processing tested and debugged&amp;lt;br&amp;gt;&lt;br /&gt;
* Ready for integration with mi2b2 client.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Migrated to Latest Slicer 3.6.3 stable release: only the Input scene had to be updated, the API remained the same&lt;br /&gt;
* Tested EM Segmenter with CMTK4Slicer extension - processing takes to much time on Linux_64bit machine, rolled back to BRAINSFit registration. When used on Mac OS X build, the Slicer could not start (bug report 1126).&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SPECTRE Scull Stripping:&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Testes for various use cases: the module is extremely sensitive to T1 MRI quality (does not work for most MRIs from PET/CT project&lt;br /&gt;
* TODO next week: check for FLAIR images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Slicer4 QT GUI and Cropping activity in progress.&amp;lt;br&amp;gt;&lt;br /&gt;
* Tried direct MRA to MRA registration option: resampling with LMRI registration transforms works better.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Extra VOI labels revised&lt;br /&gt;
* Debugging of SUV results' renormalization step&lt;br /&gt;
* TODO: ICC extraction / whole brain total uptake computing; EM Segmentation for R_WM, L_WM SUV computing and BPH estimation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SCULL STRIPPING/SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Installed and tested CLI option on Linux_64bit platform&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Workflow interruption before BSPline registraton: BPEL Module completed. Slicer4 QT GUI and Cropping activity in prorgess.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Implemented and Tested with end-users proposed changes: denormalization of SUV results, adding more VOI labels, added FLAIR MRI in addition to T1s for VOI drawing&lt;br /&gt;
* Tested manual ICC extraction using PET scans: works satisfactory with island removal and cropping followed by threshold level labeling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4&lt;br /&gt;
* Change proposed: interrupt workflow after affine registration and have user crop the VOI. This is to prevent excessive deformations for BSpline registration and resampling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4. User has option to choose the atlas that fits better for the given subject (NOTE: hardcoding must be rewritten for atlas linking)&lt;br /&gt;
* PETCT test - the problem is that T1s are low resolution and with contrast. Proposed using T1s without contrast&lt;br /&gt;
* PETCT change request: users wants to compute SUV for entire ICC. Had demo how to segment brainmask/ICC using PET scan. The derived brainmask label can be used for SUV computation.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - cmpleted&lt;br /&gt;
* Sample cases run - excessive deformation after BSpline registration hase&lt;br /&gt;
* Next week plan - pull tuning controls to front-end of pipeline API, start working of QT module for CARMA registration&lt;br /&gt;
* May consider other than BRAINSFit registration modules&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Design plan for change request: more VOI labels, add FLAIR in addition to T1 for VOI drawing, T1s segmentation&lt;br /&gt;
* Tested segmentation for sample cases - artifacts from poor quality MRIs lead to exclusion of parts of ICC from segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Completed troubleshooting of EMSegmenter module calling from Java (need TCL libs to be pulled from Slicer environment)&lt;br /&gt;
* Tested EMSegmenter autoruns for HIV and Pediatric MS patiens. Work as expected, subject to improvement of PED MS case segmentation by building better skull/neck/air atalses&lt;br /&gt;
* Suggested usage of two subsets of atalases: with and without neck. The Subject MRIs have to be cropped accordingly or best fit atlas has to be selected&lt;br /&gt;
* Made no-neck cropped atlas collection for default EMSegmenter scenario&lt;br /&gt;
* Tested with PET/CT study MRI cases - see above &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - in progress&lt;br /&gt;
* Next week goal - have back end processing ready&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Longitudinal Study&lt;br /&gt;
* Added MRI registration to the pipeline&lt;br /&gt;
* Troubleshooting of complex XML schema issues on Linux machines (some modules working on MAC do not work on Linux). As a workaround - did not include MRI convert and register part into base BPEL module. Used separate services (transparent for end-user)&lt;br /&gt;
* TODO next week for change request completion: explicit pixel type casting for MRI in BRAINSFit, VOI MRML scene update (currently MRI added on top of schema)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* February 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipeline for Pediatric MRI. Same scenario as for HIV Project, icbm pediatric atlases (Completed, verified)&lt;br /&gt;
* Collected NIH healthy brain development atlases: various age ranges from 4.5 to 18 yo. Converted to Slicer readable format &lt;br /&gt;
* Work on web services for the new automated EM Segmenter module (release Nov 10 - current). Verified task completion both for adult and pediatric images. Discussed tuning parameters for work load balance on workstations.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Started working on MRI registration to the reference CT scans. &lt;br /&gt;
* Design specs for optional White Matter segmentation for SUV computing.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* February 4, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipelines for Pediatric MRI (in progress)&lt;br /&gt;
* Adapting Pediatric T1 atlases for &amp;quot;Human Brain&amp;quot; build-in EM Segmentation wizard (in progress)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 28, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Verifying EM Segmenter module for latest builds and HIV/PED MS Studies (report pending)&lt;br /&gt;
* Work with SPECTRE module developers with pediatric MRI brainmask extraction&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* January 21, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Compiling plan for WF FrontEnd GUI migration to Slicer4/QT Widgets&lt;br /&gt;
* Preparing for annual progress report&lt;br /&gt;
&lt;br /&gt;
* January 14, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI: Integrated into the Slicer4 as Slicelet (or thin Client)&lt;br /&gt;
* Participation at AHM-2011, discussing integration of SPECTRE module and updated approach to EM-Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA&lt;br /&gt;
&lt;br /&gt;
* January 7, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* HIV project workflow delivered. Major additions relate to user convenience: &lt;br /&gt;
- Project-specific parameter settings, importing T1s and brainmasks from FreeSurfer outputs with conversion to NIFTI, resampling brainmask to original scans and automatied subject addition.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Follow up with end user: need to add MRI scans, if available, addition and registration to CT in order to ease VOI drawings.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
 &lt;br /&gt;
* December 31, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Follow-up with user Experience for AGING Study Segmentation (Positive feedback)&lt;br /&gt;
* Target date for HIV project delivery - next week&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Self-training for QT widget development&amp;lt;br&amp;gt;&lt;br /&gt;
* Outlined Workflow Rich Clients migration strategy from Java to QT/Slicer4:&amp;lt;br&amp;gt;&lt;br /&gt;
** Use Java Stubs (similar to SPECTRE integration) or file binding for envocation of workflow pipelines. (See SOAP remark below)&lt;br /&gt;
** Direct Web Servisec calls must be wrapped into REST protocol. The reason: NON-commerchial QT kit does not include SOAP protocol for web servises.&lt;br /&gt;
** The GUI will be implemented as page widget or QT dialog GUI forms called from within Slicer4.&lt;br /&gt;
** Communications between Slicer4 and WF GUI will be set via child-parent and signal-slot relations&lt;br /&gt;
* Worked on a Prototype for Basic EM Segmentation QT widget (70% complete). Will work on integrtion with SLicer4 during the AHM-2010&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
XNAT Integration&lt;br /&gt;
* Debugged XNAT RESTFul API usage for uplaoding DICOM series followed by header data extraction and image snapshots creation&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Added compensation for failed atlas registration (subject for old poor quality pseudo-T1 images): blank probability maps are created in case of failure.&lt;br /&gt;
* Data preparation module for FreeSurfer data import near completion. Expected time for deployment at end-users workstations - first week of January&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Discussed strategy for EM Segmentation pipeline solutions collection (K. Pohl, R. Kikinis)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* RE-using the same core workflow as for 1-channel EM Segmentation of AGING STUDY cases&lt;br /&gt;
* Added data input preparation module: ICC label mask preparation and skull-stripping based on FreeSurfer brainmask output volume.&lt;br /&gt;
* Two-channel EM segmentation pipeline (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE / GENERAL Development &amp;lt;br&amp;gt;&lt;br /&gt;
* Worked on plans for migrating fro rich workflow Java clients to embedded workflow windows inside the Slicer.&amp;lt;br&amp;gt;&lt;br /&gt;
The embedded workflow management clients are to be implemented with QT/PyQT toolkits&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
INTEGRATION WITH XNAT:&amp;lt;br&amp;gt;&lt;br /&gt;
* Automated DICOM series upload with triggering DICOM headers parsing at XNat site (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress. &lt;br /&gt;
- Results upload to XNat (Completed) &amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat based on user's input (Project + Subject + PET or CT session / scan) (Completed)&amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat - perfomance boosting solution for downloads found , web services services are created, relinking for the client side in progress &amp;lt;br&amp;gt;&lt;br /&gt;
- Xnat querying for subjects and automated subject addition into the workflow (In Progress) &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-segmentation module added for auto correction of segmentation results. Particularly - relabeling CSF voxels segmented as Air inside the intracranial cavity. This was requested by end-users after processing images with zero-signals in CSF voxels &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting automated dual-echo DICOM images conversion and split into two NRRD volumes&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT / EM Segmentation pipeline:&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting memory allocation issues for scull-stripping module SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
COPD Project:&amp;lt;br&amp;gt;&lt;br /&gt;
* Benchmark test for accelerated DICOM downloads from XNat (remoote XNat Central server): we can handle at least 6 cases (4 CT scans in each) per hour, which is compatible with current workload quotes on SPL cluster processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* December 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Deployed Version 1. &amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Test project chosen as a closest match to registration scenario: Pediatric MS Cases from MGH - requires periodic image preview for different &lt;br /&gt;
modalities taken from vaious time points. Label maps for VOIs resampling is also required.&lt;br /&gt;
&lt;br /&gt;
* November 26, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user. Version 1 is complete&amp;lt;br&amp;gt;&lt;br /&gt;
* Started working on integration with XNat&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on input data organizing modules&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 19, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user (70% done)&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Universal Registration Workflow for Longitudinal Studies - design specs in progress&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 12, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Minor tuning to EM Segmentation template as of users' feedback&lt;br /&gt;
* Users started using the workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed input data conversion from Genesis to Slicer native or NIFTI format. Our help may be needed in input data organizing.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Tuned application according to co-laborators (PNL) needs&amp;lt;br&amp;gt;&lt;br /&gt;
* The webservices and BPEL workflow application are tested ready to accept computation requests from PNL case tracking system &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Discussed Universal Registration Workflow for Longitudinal Studies&lt;br /&gt;
* Started the thread about possible cooperation with Children hospital's image processing pipelines and integration with Xnat &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 5, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Webservices and workflow pilot project created and deployed on Psychiatry Neuroimaging Laboratory subnet &amp;lt;br&amp;gt;&lt;br /&gt;
* The V.1.0 deployment is scheduled for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 29, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Most of functionality is completed. Some volume statistics post processing is pending&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL EM SEGMENTATION Pipeline: &amp;lt;br&amp;gt;&lt;br /&gt;
* The SPECTRE scull stripping module. Started integration into EMS workflow. Made some test runs from Slicer GUI&amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Identified as a candidate for Workflow Application&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 22, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* All back-end functionality are implemented&amp;lt;br&amp;gt;&lt;br /&gt;
* EM Segmentation scene usability is confirmed by end-user&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for next week: add Label Statistics computation for CSF/Brain/ICC &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 15, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* The latest (October) builds of Slicer 3.6.2 produced acceptable results. This was verified by the target users. The EM Segmentation will be performed on Slicer 3.6.2 or later&amp;lt;br&amp;gt;&lt;br /&gt;
* The new Web services had been created and added to the pipeline as optional processing steps: Biasfield correction (implement novel N2ITKBiasFieldCorrection module) and Volume's scalar datatype casting (as workaround for Biasfield correction module not preserving image scalar datatype - the bug is filed) &amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed the Front-End GUI design with target users. The design pattern is taken from the PETCT project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 8, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-deployment support. Tuned CT registration as of user's feedback.&lt;br /&gt;
* Adapting to the Single Slicer build: Slicer 3.6.2. Found label duplicates in the label lookup table - will ask user if it's tolerable. Waiting for the Slicer 3.6.2 build that contains all required modules. Rolling back label tag appending code for SUVs - the latest Slicer build appends the tags.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Resumed development. The priorities are set for usage of Slicer 3.6.2 - subject for EM Segmentation scene tuning. Continued coding for Scene creation for Slicer 2.8 - as a backup option for ongoing research project.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 1, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized V1.0 release based on end-user feedback: updates relate mostly to error proofing and SUV values representation&lt;br /&gt;
* Post-deployment support. Users pre-processed first set of patients &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* September 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* System deployed and tested at End Users' site.&amp;lt;br&amp;gt;Users are trained to perform all tasks required by the workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
* Got positive feedback with suggestions on Slicer Scenes' layouts improvement and PET scans' SUV (standard uptake values) results display&lt;br /&gt;
* Two distribution packages are assembled: Lunix and MAC OS versions. The difference in two packages is in specific Slicer3.6/3.7 builds - subject to Slicer Linux builds debugging.&amp;lt;br&amp;gt; As a workaround for Linux deployment - multiple Slicer builds are used to perform various tasks (registration, opening editing scenes in Slicer, SUV computing)&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for coming week - finalize V1.0 release based on end-user feedback&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Embedded SUV computations into the workflow (as system calls - will be translated into web service later)&amp;lt;br&amp;gt;&lt;br /&gt;
* Pre-release demo for end users.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Create and debug EM Segmenter scenes template for Slicer 3.6 and 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* September 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation - workflow pipeline and deployment verified&amp;lt;br&amp;gt;&lt;br /&gt;
* Tested EM Segmentation scenes within Slicer 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
* Started migration of EM Segmentation to Slicer 3.6. Discovered issues had been reported to EM Segmenter module designers &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* August 29 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation completed. Preprocessing Pipleine completed 80% (subject for input registration parameters tuning) &amp;lt;br&amp;gt;&lt;br /&gt;
* Most webservices (for registration and resampling steps) had been taken and re-used from PET/CT ROI/Longitudinal Study - showing the advantage of service-oriented software design and deployment.&lt;br /&gt;
* Continued on distribution and deployment of the service/workflow applications: on PET/CT and AGING STUDY projects.&lt;br /&gt;
&lt;br /&gt;
PEDIATRIC Multiple Sclerosis Cohort. Support of multi-center distributed processing project&amp;lt;br&amp;gt;&lt;br /&gt;
* Introduced Slicer 3.6 for the MS Lesion Assessment step performed at Mayo Clinic. Images are being transferred from image repository at BWH and automatically opened and arranged within Slicer GUI for reading.  This was replacement of Client GUI using MIPAV that stopped working on new computers at Mayo Clinic.&lt;br /&gt;
The images are being loaded via generated MRML Scenes same way as in PET/CT and AGING STUDY projects &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* August 22 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Preprocessing pipeline merge with SUV computations &amp;lt;br&amp;gt;&lt;br /&gt;
- QA for SUVs computation was performed by Wendy Plesniak for images with known uptake values. &amp;lt;br&amp;gt;&lt;br /&gt;
- Discovered that image cropping step (not related to automated registration pipeline and SUVs computing) smoothes the images by doing interpolation when used with default settings. Got suggestions from Steve Piper using Nearest-Neighbor interpolation (&amp;quot;no interpolation&amp;quot;) for a time being&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
- This is the new project candidate. Requested for the images with failed manual segmentation and/or segmentation with FreeSurfer. The EM Segmentation run showed most acceptable results on one of the problem images back in February &amp;lt;br&amp;gt;&lt;br /&gt;
- The workflow will be developed and deployed similar to PET/CT ROI Longitudinal study approach - all preprocessing steps will be done with Slicer modules, all runs will be performed on local end-user machines.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
 &lt;br /&gt;
&lt;br /&gt;
* August 15 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- First 5 cases with 3-4 time points preprocessed for SUVs computation&lt;br /&gt;
&lt;br /&gt;
* August 8 2010&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Testing of installation and operation at users' site (Performed by Wendy Plesniak)&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* July 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Delivered beta version of registration pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
- Prepared installation and user manuals &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* June 11, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Registration modules completed &amp;lt;br&amp;gt;&lt;br /&gt;
- Irregular cases registration problem solved (when whole body and brain only scans are mixed for a timepoint)&amp;lt;br&amp;gt;&lt;br /&gt;
- Live demo of case setup and registration workflow for end users. Real case with 4 timepoints used&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Coming week plans&amp;lt;br&amp;gt;&lt;br /&gt;
- Adjust workflow based on end users' feedback&amp;lt;br&amp;gt;&lt;br /&gt;
- Integration with SUVs computing for PET scans&amp;lt;br&amp;gt;&lt;br /&gt;
- GUI for workflows dispatching and data organizing&amp;lt;br&amp;gt;&lt;br /&gt;
- (TBD) Integration with 4D time series analysis Slicer module&amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
* May 28, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- Migration to the latest Slicer 3.6 release candidate &amp;lt;br&amp;gt;&lt;br /&gt;
- Added webservice for new registration module: BRAINSFit &amp;lt;br&amp;gt;&lt;br /&gt;
- Test runs for new patients with 4 timepoints' scans &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Plans for next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI &amp;lt;br&amp;gt;&lt;br /&gt;
- processing workflow demo for end user &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 21, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Pilot version of portable web services and automated workflow tested: &amp;lt;br&amp;gt;&lt;br /&gt;
Linux: workflow and visual review passed&amp;lt;br&amp;gt;&lt;br /&gt;
Stress test for 25 timepoints passed &amp;lt;br&amp;gt;&lt;br /&gt;
MAC OS: workflow passed, visual review failing when PET/CT images are loaded into GUI simultaneously (bug report submitted)&amp;lt;br&amp;gt;&lt;br /&gt;
Windows: need to adapt command line modules and workflow management system to sygwin environment&amp;lt;br&amp;gt;&lt;br /&gt;
Plans for next week: integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI&lt;br /&gt;
&lt;br /&gt;
* May 7, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Selected registration and resampling modules with more precise and stable outputs. &amp;lt;br&amp;gt;&lt;br /&gt;
Started building portable web services and automated workflow &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 30, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- manual walk through the processing steps: ROI cropping, registration/resampling, PET pharmaceutical DICOM data retention. &amp;lt;br&amp;gt;&lt;br /&gt;
- testing workflow and web services packages distribution to end-users' machines&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* April 23, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : testing various registration and re-sampling algorithms (work in progress)&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation: as of collaborators' request, run existing EM Segmentation workflow for older low resolution pseudo-T1 images. The EM Segmentation works for those images with manual sampling. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 16, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
  Social Cognition Study: started Cortical Thickness Measurement module build (bases on NA-MIC ARCTIC pipeline) &amp;lt;br&amp;gt;&lt;br /&gt;
  PET/CT ROI/Longitudinal Study Registration : Design specs, PET-to-CT images registration tests on training data. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 9, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. GUI update based on end-user experience.&amp;lt;br&amp;gt;&lt;br /&gt;
User request: automated label maps' volumes calculation (Currently possible from Slicer3 GUI)&amp;lt;br&amp;gt; &lt;br /&gt;
PET/CT ROI Project. Initial design specs discussion with end-users and co-developers&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure&lt;br /&gt;
Verification of segmentation workflow GUI: from registering new case to reviewing results&amp;lt;br&amp;gt;&lt;br /&gt;
Cross study test of segmentation workflow: MGH/MS Center data - success,  HIV Project data - some EM Segmentation scene tuning is needed &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*&lt;br /&gt;
* April 2, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. Segmentation workflow completed&amp;lt;br&amp;gt;&lt;br /&gt;
* Coming Week plans:&amp;lt;br&amp;gt;&lt;br /&gt;
- Document Segmentation Workflow. Follow up with end users &amp;lt;br&amp;gt;&lt;br /&gt;
- Start with Cortical Thickness and ROI-in-longitudinal studies workflows&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* March 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All essential processing and workflow interaction clients are ready.&amp;lt;br&amp;gt;&lt;br /&gt;
- Completed segmentation for 10 out of 50 patients. The remaining cases will be finalized upon manual lesion segmentation and QC verification of WM/GM/CSF and Deep GM segmentation's. &amp;lt;br&amp;gt;&lt;br /&gt;
- TODO next week: refine QC GUI and data tracking / progress monitoring schema. &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&amp;lt;br&amp;gt;&lt;br /&gt;
- New Slicer3 web services added: re-slicing with reference image volume, casting image scalar type &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
* March 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Segmentation maps Merging Services for GM/WM/CSF (Slicer EM Segemnter), Lesion (Slicer, Manual), and Deep GM (FreeSurfer)  &amp;lt;br&amp;gt;&lt;br /&gt;
- Deep GM segmentation pipeline adopted as optional service for Social Cognition Study (22 out of 50 cases processed) &amp;lt;br&amp;gt;&lt;br /&gt;
- (In progress) GUI client for Launching Segmentation results merging with optional Deep GM segmentation with FreeSurfer &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- Complete GUI Client for Segmentation result merging &amp;lt;br&amp;gt;&lt;br /&gt;
- Progress Monitoring services for entire Study processing: EM Segmenter Preprocessing, EM Segmentation, Lesion Segmentation (including human activities assignments), Deep GM segmentation, and results consolidation. &amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* March 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All 50 cases went through &amp;quot;basic&amp;quot; One-channel EM segmentation (GM/WM/CSF) &amp;lt;br&amp;gt;&lt;br /&gt;
- Basic pipeline start-up command line client created: user has two options - request brainmask extraction or provide with previously extracted brainmask for a given subject &amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison of GM/WN/CSF performed for Slicer EM Segmenter and FreeSurfer recon-all (used with default settings). &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmenter provides more accurate output &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmentation pipeline runs faster (40 minutes vs 12 hrs when no brainmask extraction requested) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO:&amp;lt;br&amp;gt;&lt;br /&gt;
- merging modules for automatic 1-channel EM segmentation and manual lesion segmentation &amp;lt;br&amp;gt;&lt;br /&gt;
- Emerge Cortical Thickness pipeline project: use NAC ARCTIC processing steps and modules &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Selected stable EM Segmentation scenario: White Matter, Gray Matter, and Cerebrospinal Fluid &amp;lt;br&amp;gt;&lt;br /&gt;
- First 16 cases are segmented for selected scenario. Nine more cases are preprocessed for EM Segmentation.&amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison to segmentation with FreeSurfer showed better accuracy for Slicer2 EMSegmenter &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure &amp;lt;br&amp;gt;&lt;br /&gt;
- Three prerpcocessed cases failed during volume ICC masking with in-house build utility. Evaluated switching to Slicer3 Mask and island removing modules.&amp;lt;br&amp;gt;&lt;br /&gt;
- Initial design specs discussion for cortical thickness measurement pipeline. ARCTIC pipeline selected. ARCTIC preprocessing steps signifficantly overlap with EM Segmentation preprocessing workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
  &lt;br /&gt;
* February 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: &amp;lt;br&amp;gt;&lt;br /&gt;
A) parameters tuning for EM Segmenter itself (work with EM Segmenter developer), template scenes creation &amp;lt;br&amp;gt;&lt;br /&gt;
B) update preprocessing pipeline - deep gray matter atlases included &amp;lt;br&amp;gt;&lt;br /&gt;
C) test and debug preprocesing pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
D) identified missing modules: atlas autocalibration for EM Segmentation scene, Island removal for ICC mask&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- Review currently deployed modules. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: reviewed firts seven subjects' outputs, added volume orientation module into pipeline (prevents ICBM atlas linear registration failures)&amp;lt;br&amp;gt;&lt;br /&gt;
- Fused ICC(brainmask) extraction module with EM Segmenter preprocessing. Three scenarious implemented: start with pre-extracted ICC mask (longitudinal studies case), run with ICC ectration, run with ICC extraction AND ICC correction before ICBM atlas preporcessing. &amp;lt;br&amp;gt;&lt;br /&gt;
- Completion of Human activities GUI (QC, ICC Correction) planned for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: Volume Orientation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: automated preprocessing pipeline for Slicer2 EM Segmenter test version deployed. Seven cases pre-processed.&lt;br /&gt;
- PET Quantitative measurements: Preliminary design specs discussion.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: BSplineRegistration (for non-linear registration), ResampleVolume2 (for atlases resampling based on image atlase templates registration). Local and Network runs are implemented, Cluster/GridWizard implementation pending.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Slicer EM Segmenter module: preprocessing design for Slicer2 EM Segmenter&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Adapting for Slicer2 EM Segmenter (mostly from pipelines and services for previous projects)&lt;br /&gt;
  -- Integration with FreeSurfer modules for bisafield correction, brainmask extraction, and linear registration of ICBM atlases&lt;br /&gt;
  -- Preprocessing updates for non-linear registration of ICBM atlases with Slicer2 (image re-orientation service designed)&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 29, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- EM Segmentaton pipeline: preprocessing results are being transferred to XNat (anonymized data, Central XNat) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Slicer EM Segmenter module: discussed agenda and scheduled a work meeting for Social Cognition Study image segmentation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Testing stage, 95% completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- SPL XNat server: verified data exchange via RESTfull web services.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 22, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Follow up with White Matter Lesion Segmenter and Scull Stripping Modules developers: Work in Progress&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Work in Progress, 60%+ completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Discussed SPINE image repository migration to XNat&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 15, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. &lt;br /&gt;
- Social Cognition Study: &lt;br /&gt;
Work-in-progress on intermediate (reconstruction) and results (resources) data storage at XNat.&lt;br /&gt;
&amp;lt;br&amp;gt;Reviewing and preparation more cases for EM Segmentor (Slicer 3.5) tuning.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* NA-MIC Project Week&lt;br /&gt;
Selecting candidate Slicer modules for other than Lesion EM Segmentation topics of Social Cognition study: Withe Matter Lesion Segmenter (UNC), Scull Stripping utility from UIOWA.&lt;br /&gt;
Reviewing issues of currently used Scull Stripping Slicer Extension and Slicer 3.5 EM Segmenter.&lt;br /&gt;
&amp;lt;br&amp;gt;XNat Data organizing training&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 1, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Preparation of Demo for NA-MIC work week: &lt;br /&gt;
- COPD Study. Added Remote pipepline start interface (represents real world scenario where Xnat repository, Processing modules and User are at different sites)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
- EM Segmentation. Added human activities steps to the workflow: ICC (brainmask) correction and EM Segmantation scena load per se.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 25, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Pilot workflow pipeline for EM Segmentation (all steps except user-activity step: ICC correction assignment and tracking)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 18, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Build and tested web services for EM Segmentation image preprocessing: DICOM-to-NRRD conversion, registration, skull stripping, image masking.&lt;br /&gt;
Started building workflow pipeline (subject to finish first version next week)&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Started Collecting Library of Slicer Build number vs. functional modules and extensions.&lt;br /&gt;
Plan for NAMIC project week: scheduled meetings for XNat data customization, Skull-stripping modules tuning, identified Social Cognition study cases that fail EM Segmentation processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 11, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Updating and verification of EM Segmentation Scenario&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Projects:ARRA:SlicerWF:UseCaseScenarios#Usecase_MS_lesion_Assessment&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Familiarizing with Slicer3.4/5 Modules required for implementation of EM Segmentation Scenario. Participation in debugging and/or usage tuning of Dicom Conversion, Registration, Skull Stripping, Masking, and Image Casting modules. &lt;br /&gt;
&lt;br /&gt;
* December 4, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Slicer3.4's EM Segmentation and Visual QC as part of image processing pipeline for Social Cognition Study for MS Patients.&lt;br /&gt;
Project emerged. EM Segmentation template creation debugged.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
Emphysema Measurements (COPD Study) - workflow stability and scalability test.&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 27, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Emphysema Measurements (COPD Study).&lt;br /&gt;
Added compensation for long running calculations and time-outs to the main computing pipeline.&lt;br /&gt;
Visual QC (work in progress)&lt;br /&gt;
** Infrastructure&lt;br /&gt;
XNat data structure customization, metadata storage, results consolidation: new feature request list creation (work in progress)&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 13, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
*** Pilot system for whole processing cycle for Emphysema Measurements (COPD Study) including the following:&lt;br /&gt;
Web query for CT session file list download&lt;br /&gt;
Pilot user interface for submitting the file list and starting processing pipeline&lt;br /&gt;
Notification about processing steps and failures&lt;br /&gt;
Upload results to XNat repository (at this stage results are uploaded into same folder where original scans are(*))&lt;br /&gt;
*** Immediate Plans&lt;br /&gt;
Complete Visual QC module&lt;br /&gt;
Design and implement meta-data transfer to XNat (including processing details and MRML files for loading images into the 3D Slicer)&lt;br /&gt;
&lt;br /&gt;
(*)Customization of results storage&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 6, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Tuned and debugged multiple subjects processing for: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat.&lt;br /&gt;
***Started working on quality control embedding into the above scenario. Plan to complete and video-record demo next week.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***Published general Product Integration scenario flow chart to collaborators' community. Discussion is open and in progress&lt;br /&gt;
&lt;br /&gt;
* October 30, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Piloted and tested the sequence: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat(1).&lt;br /&gt;
***Performance test of overall cycle: data transfer from remote serve is a bottleneck as expected&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data browsing features reviewed.&lt;br /&gt;
(1) Not automated yet&lt;br /&gt;
* October 23, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Defined COPD processing scenario with interoperability between Xnat, 3D Slicer Command Modules, Workflow, and Gridwizard Enterprise.&lt;br /&gt;
***Pilot version of Emphysema Measurements workflow pipeline deployed.&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data transfer features reviewed. Use account at XNat Central during learning curve.&lt;br /&gt;
***Feasibility test of 3D Slicer fiducials module for ROI highlights during QC and manual image processing activities. &lt;br /&gt;
* October 16, 2009&lt;br /&gt;
**Lung CT Scans Processing. Pilot project emerged. GenerateEmphysemaMeasurements module deployed as a webservice that submits jobs to computational cluster.&lt;br /&gt;
**EM Segmentation. Familiarized with GUI steps. Started working on automation steps outlining&lt;br /&gt;
**3D Slicer and XNat interaction. Got an overview from Wendy Plesniak.&lt;br /&gt;
* October 1 - 7, 2009&lt;br /&gt;
**Selected two first priority Projects: EM Segmentation of brain MRI images; Lung CT Scans Processing (COPD Study)&lt;br /&gt;
**Got initial outline of user requirements and design specs&lt;/div&gt;</summary>
		<author><name>Azaitsev</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=67178</id>
		<title>Projects:ARRA:SlicerWF</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=67178"/>
		<updated>2011-05-16T03:12:49Z</updated>

		<summary type="html">&lt;p&gt;Azaitsev: /* Progress */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Projects:ARRASuplements|Back to Slicer ARRA home page]]&lt;br /&gt;
= Aim =&lt;br /&gt;
Supplement 3D Slicer and Extensible Neuroimaging Archive Toolkit (XNAT) with workflow management system. Provide integration and interoperability between 3D Slicer, XNAT Services and 3-rd party image processing applications and high performance computing systems. Implement it as within currently developed Structural Planning and Implementation in Neurological Exploration (SPINE) System.&lt;br /&gt;
&lt;br /&gt;
= SPINE Project Documentation =&lt;br /&gt;
[http://cni.bwh.harvard.edu/projects/spine/index.html SPINE Docs]&lt;br /&gt;
&lt;br /&gt;
= Presentations =&lt;br /&gt;
* Segmentation Workflow. PECS University Social Cognition Study.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:SlicerWF_NAC_PECS_Workflow.pdf]]&lt;br /&gt;
* EAB10_ARRA Annual Progress Report Slides.&amp;lt;br&amp;gt;&lt;br /&gt;
[[media:EAB10_ARRA_WF_2011_Zaitsev.ppt | Service Oriented Solutions for 3D Slicer. EAB10_ARRA_WF_2011. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:EAB10_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:NAMIC_ARRA_WF_2011_Zaitsev.ppt  | NAMIC Annual Report 04/2010-03/2011. NAMIC_ARRA_WF_2011_Zaitsev. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:NAMIC_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:Slicer_WF_Slicer4CARMAWorkflow.ppt  | CARMA Workflow. Cardiac Ablation Followup. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:Slicer_WF_Slicer4CARMAWorkflow.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* CARMA Project Beta release Demo Location: http://cni29.bwh.harvard.edu/SlicerWFDemo/index.php&lt;br /&gt;
&lt;br /&gt;
* Segmentation Workflows: Screenshots, scans' and study description : [[File:SlicerWF_EMSegmentProjectsReview.zip]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
= All Hands Meeting Pages =&lt;br /&gt;
* Salt Lake City 2011 Winter [http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA SLC_2011_WorkFlow]&lt;br /&gt;
* MIT 2010 Summer [http://wiki.na-mic.org/Wiki/index.php/Summer_project_week_2010_Workflows_SOA MIT_2010_WorkFlow]&lt;br /&gt;
&lt;br /&gt;
= Research Plan =&lt;br /&gt;
*Create a stand-alone SPINE desktop agent with fully functional data exchange and communication mechanisms towards 3D Slicer and XNAT.&lt;br /&gt;
*Develop Service Oriented Architecture (SOA) SPINE System that will include 3D Slicer image processing modules deployed as web services as well as a workflow management system to orchestrate interaction between 3D Slicer, XNAT, and 3-rd party tools.&lt;br /&gt;
*Implement two-way control and communications between 3D Slicer and SPINE modules.&lt;br /&gt;
*Adapt SPINE System for cluster and grid computing scenarios.&lt;br /&gt;
*Provide with workflow and 3D Slicer web service wrappers editing tools.&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:UseCaseScenarios| Use Case scenarios]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PETCTWorkflow| PETCTWorkflow]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:AgingStudySegmentation| AgingStudySegmentation]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:TwoTensorTractography| TwoTensorTractography]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:LongitudinalMultimodalityRegistrationSuite| LongitudinalMultimodalityRegistrationSuite]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:MigrationJavaClients2QT| MigrationJavaClients2QT]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PediatricMSSegmentation| PediatricMSSegmentation]]&lt;br /&gt;
*[[DBP3:Utah:RegSegPipeline| MRI-based study and treatment of atrial fibrillation]]&lt;br /&gt;
&lt;br /&gt;
= Application Server / Workflow Engine Downloads =&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:WFEngineDownloads| Download Links]]&lt;br /&gt;
&lt;br /&gt;
=Key Personnel=&lt;br /&gt;
* Charles Gutmann, MD., 4%,  9-17-2009 through 9-16-2011&lt;br /&gt;
* Alexander Zaitsev, Ph.D., 75%, 9-17-2009 through 9-16-2011 &lt;br /&gt;
&lt;br /&gt;
=Annual Progress Statements =&lt;br /&gt;
'''2010-11''' &amp;lt;br&amp;gt;&lt;br /&gt;
The  April 2011 – March 2011 period was devoted on developing portable workflow solutions that can be deployed on end-users' workstations or notebooks with minimal or no system administration activities. This is in contrast to the server-side deployment. The following scenarios had been deployed and used for actual projects that require the following types of workflows: PET/CT registration and computation of biomarker driven brain physiological activities, Brain MRI Images segmentation,  MRI and MRI Angiography images pre-processing for cardiac ablation outcome estimation. Some  workflows (like EM Segmentation) had been utilizing various scenarios, some research projects  (like evaluation of chemotherapy outcome) require two types of workflows to assess physiological and structural changes. Starting from the 4th Quarter of 2011, the migration project had been emerged in order to embed Workflow GUIs into newly developed Slicer4 Suite. The existing rich client Java GUI applications are being re-written as C++/QT Sliceletts units, new modules (such as cardiac ablation project support) are had been written from scratch. The latter are being deployed from the Slicer4 GUI and act at a liaison between Slicer4 and Application Server containing  workflow and Slicer modules deployed as services. The feedback from the end users indicates that Workflow approach for the complex processing improves productivity, aids to the processing standardization and contributes to the overall experience using 3D Slicer&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
=Quarterly Progress=&lt;br /&gt;
&lt;br /&gt;
* NAMIC Annual Progress Slides (April 2010 - March 2011):&lt;br /&gt;
&lt;br /&gt;
* '''1st Qtr, 2011''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study: Second release is under testing by end-users. &lt;br /&gt;
*** Added MRI registration to aid ROI drawing on PET scans&lt;br /&gt;
*** Improved SUV results reporting and added flexibility to update ROI lookup table&lt;br /&gt;
*** Automated EM Segmentation of MRI images for computing SUVs for white matter, CSF, and whole brain (80% completion)&lt;br /&gt;
*** Integration with SPECTRE scull stripping module (70% completion) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** EM Segmentation: Automated WF Pipelines are created &amp;lt;br&amp;gt;&lt;br /&gt;
*** Flexible atlas selection (Pediatric, etc) feature added&lt;br /&gt;
*** Workflows implemented for EM Segmenter 3.6.2 and 3.6.3 (1st Qtr 2011 release)&lt;br /&gt;
&lt;br /&gt;
** Cardiac ablation results follow-up: Workflow for registration and ROI selection of cardiac MRI and MR Angiography &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Wrokflow and Web Services for prospective DTI tractography modules (currently written as Matlab modules at PNL) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Web Services for SPECTRE Scull stripping module&lt;br /&gt;
*** Accuracy and performance tuning&lt;br /&gt;
*** 50% completion&lt;br /&gt;
&lt;br /&gt;
** Migration Front End GUI to Slicer4/QT:&lt;br /&gt;
*** EM Segmentation&lt;br /&gt;
*** Cardiac Ablation Study&lt;br /&gt;
&lt;br /&gt;
** DICOM Uploader and Desktop Browser for XNat Image repository (alpha version - tested for MGH MS Center studies, proposed to use with MI2B2 Clients and Services)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''4th Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study and EM Segmentation for Aging Study are deployed at end-user sites and actively used for research. &lt;br /&gt;
** Adopted EM Segmentation preprocessing pipeline for HIV Study: high resolution SPGR images, integration with FreeSurfer brainmask extraction outputs; integration of Slicer SPECTRE module for brainmask extraction is in progress.&lt;br /&gt;
** The following post-release upgrades had been implemented based on end-user feedback: Application Server basic controls are performed from Rich Client GUI as alternative to traditional IT administration activities. The controls are implemented on point-and-click bases and include web services and workflow application deployment and upgrades, application server start and stop as well as warning end user when the server is not accepting request.&lt;br /&gt;
** Added DICOM downloads and results uploads of PET/CT pipelines from and to XNat Repository&lt;br /&gt;
** Created Services and Workflow for Matlab Prototypes modules. Case Study: tractography for DTI images&lt;br /&gt;
** Extended XNAT integration services:&lt;br /&gt;
*** Browsing capabilities of XNat data repository from the Workflow Applications&lt;br /&gt;
*** Improved DICOM upload and download performance&lt;br /&gt;
*** Added Metadata organizing services for uploaded DICOM images: header data extraction, image snapshots creation. &lt;br /&gt;
** Started project for Rich Client GUI migration from Java desktop application to build into SLicer4 QT modules. This affects mostly front-end GUI and has the following approaches: distribution with the Slicer4, end-user will select desired workflow application from Slicer4 menu while QT-written modules provide with the same functionality as Java Rich Clients. Case Study for the Migration process: registration suite for longitudinal studies that include multi-modality images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* '''3d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Concentrated on building downloadable workflow applications that could run both in desktop (new) and server environment, and that require minimum IT administrative resources. The desktop deployment is in compliance with Slicer3 general deployment concept.&lt;br /&gt;
*** The following use case scenario had been chosen: PET/CT image processing for longitudinal studies, EM Segmentation for longitudinal Aging Study.&lt;br /&gt;
** Released workflow application for PET/CT image processing for longitudinal studies. Provided end users with training and documentation.&lt;br /&gt;
*** The PET/CT processing workflow was designed to be a general application used whenever both structural patterns and metabolic activities are within the research scope. &lt;br /&gt;
*** The desktop version is tuned to use minimal computer resources, so the automates processing instances do not interfere with human activities. Automated activities may include, for example, registration and PET scan's standard uptake values computing, and manual human activities may include image cropping, quality control, and labeling voxels of interest.&lt;br /&gt;
** Core services and EM Segmentation preprocessing workflow was build for retrospective Aging Study. Tuned the Slicer3 webservices for processing low grade images acquired in mid 90s. Entire workflow is implemented with Slicer3 only modules and can be deployed locally and on the servers. Usage of Service Oriented Architecture (SOA) as a core technological approach allowed reusing most of the web services that had been build for PET/CT project. &lt;br /&gt;
** Continued embedding Slicer3 application and modules into previously released processing pipelines: replaced MIPAV with Slicer3 GUI for lesion assessment step in the multi-center Pediatric MS Cohort image processing &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''2d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Completed Social Cognition Workflow Implementation. This includes EM Segmetnation pre- and post-processing pipelines, data tracking, and integration with 3d party image processing utilities, as well as processing results acquired manually with Slicer GUI.  &lt;br /&gt;
** Multi-modality image registration and ROI selection/alignment workflow for longitudinal studies. &lt;br /&gt;
*** Use case: PET/CT image processing for longitudinal studies. &lt;br /&gt;
*** Build portable library of Slicer modules as web services and workflow that are deployed and run on a end-users' worksatations without utilization of SPL and other servers. The web services include novel Slicer3 modules, such as BRAINSFit and BRAINSResamle &lt;br /&gt;
*** Started working with Slicer3 developers on Slicer 3.8 GUI wizard to communicate with workflow instances.&lt;br /&gt;
** Participated at NA-MIC Summer 2010 Project Week: [[Summer_project_week_2010_Workflows_SOA]]&lt;br /&gt;
&lt;br /&gt;
=Progress=&lt;br /&gt;
* May 13, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General / PETCT V1.1&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Hemispheres EM Segmentation - technically works with labal values hardcoded in Slicer EM Segmenter - need to add manual label value edition step&lt;br /&gt;
* PETCT WF Cut for Java GUI (Pending Hemispheres label update completion). Next release will be in QT4.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* May 6, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (QA of EM Segmenter module, work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* April 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Open Discussion for Packaging WF QT Modules as Slicer4 extensions (waiting for SOPs)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review supported projects http://wiki.na-mic.org/Wiki/index.php/File:SlicerWF_EMSegmentProjectsReview.zip &lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (required by Study)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Slicer Modules General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Standardizing Crop Volumes Output (with A. Fedorov's module). Review for required updates of existing product (PET/CT, CARMA)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Open Discussion for Packaging WF QT Modules as Slicer4 extensions (waiting for SOPs)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review supported projects http://wiki.na-mic.org/Wiki/index.php/File:SlicerWF_EMSegmentProjectsReview.zip &lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (required by Study)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Slicer Modules General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Standardizing Crop Volumes Output (with A. Fedorov's module)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 22, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Beta release ready. Demo Location: http://cni29.bwh.harvard.edu/SlicerWFDemo/index.php&lt;br /&gt;
* TODO: Tutorial. Original inputs copy/renaming&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 15, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Adding App server auto-config features&lt;br /&gt;
* Finalizing the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 08, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Second release beta build tested on cosutmer side &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review registration quality (with Dr. Meier). Angiography images' Resampling tuned. &lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 01, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the second release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
XNat Integration&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* (Java) GUI for Project Browsing and DICOM Series Upload. Post-upload DICOM processing tested and debugged&amp;lt;br&amp;gt;&lt;br /&gt;
* Ready for integration with mi2b2 client.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Migrated to Latest Slicer 3.6.3 stable release: only the Input scene had to be updated, the API remained the same&lt;br /&gt;
* Tested EM Segmenter with CMTK4Slicer extension - processing takes to much time on Linux_64bit machine, rolled back to BRAINSFit registration. When used on Mac OS X build, the Slicer could not start (bug report 1126).&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SPECTRE Scull Stripping:&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Testes for various use cases: the module is extremely sensitive to T1 MRI quality (does not work for most MRIs from PET/CT project&lt;br /&gt;
* TODO next week: check for FLAIR images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Slicer4 QT GUI and Cropping activity in progress.&amp;lt;br&amp;gt;&lt;br /&gt;
* Tried direct MRA to MRA registration option: resampling with LMRI registration transforms works better.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Extra VOI labels revised&lt;br /&gt;
* Debugging of SUV results' renormalization step&lt;br /&gt;
* TODO: ICC extraction / whole brain total uptake computing; EM Segmentation for R_WM, L_WM SUV computing and BPH estimation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SCULL STRIPPING/SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Installed and tested CLI option on Linux_64bit platform&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Workflow interruption before BSPline registraton: BPEL Module completed. Slicer4 QT GUI and Cropping activity in prorgess.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Implemented and Tested with end-users proposed changes: denormalization of SUV results, adding more VOI labels, added FLAIR MRI in addition to T1s for VOI drawing&lt;br /&gt;
* Tested manual ICC extraction using PET scans: works satisfactory with island removal and cropping followed by threshold level labeling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4&lt;br /&gt;
* Change proposed: interrupt workflow after affine registration and have user crop the VOI. This is to prevent excessive deformations for BSpline registration and resampling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4. User has option to choose the atlas that fits better for the given subject (NOTE: hardcoding must be rewritten for atlas linking)&lt;br /&gt;
* PETCT test - the problem is that T1s are low resolution and with contrast. Proposed using T1s without contrast&lt;br /&gt;
* PETCT change request: users wants to compute SUV for entire ICC. Had demo how to segment brainmask/ICC using PET scan. The derived brainmask label can be used for SUV computation.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - cmpleted&lt;br /&gt;
* Sample cases run - excessive deformation after BSpline registration hase&lt;br /&gt;
* Next week plan - pull tuning controls to front-end of pipeline API, start working of QT module for CARMA registration&lt;br /&gt;
* May consider other than BRAINSFit registration modules&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Design plan for change request: more VOI labels, add FLAIR in addition to T1 for VOI drawing, T1s segmentation&lt;br /&gt;
* Tested segmentation for sample cases - artifacts from poor quality MRIs lead to exclusion of parts of ICC from segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Completed troubleshooting of EMSegmenter module calling from Java (need TCL libs to be pulled from Slicer environment)&lt;br /&gt;
* Tested EMSegmenter autoruns for HIV and Pediatric MS patiens. Work as expected, subject to improvement of PED MS case segmentation by building better skull/neck/air atalses&lt;br /&gt;
* Suggested usage of two subsets of atalases: with and without neck. The Subject MRIs have to be cropped accordingly or best fit atlas has to be selected&lt;br /&gt;
* Made no-neck cropped atlas collection for default EMSegmenter scenario&lt;br /&gt;
* Tested with PET/CT study MRI cases - see above &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - in progress&lt;br /&gt;
* Next week goal - have back end processing ready&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Longitudinal Study&lt;br /&gt;
* Added MRI registration to the pipeline&lt;br /&gt;
* Troubleshooting of complex XML schema issues on Linux machines (some modules working on MAC do not work on Linux). As a workaround - did not include MRI convert and register part into base BPEL module. Used separate services (transparent for end-user)&lt;br /&gt;
* TODO next week for change request completion: explicit pixel type casting for MRI in BRAINSFit, VOI MRML scene update (currently MRI added on top of schema)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* February 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipeline for Pediatric MRI. Same scenario as for HIV Project, icbm pediatric atlases (Completed, verified)&lt;br /&gt;
* Collected NIH healthy brain development atlases: various age ranges from 4.5 to 18 yo. Converted to Slicer readable format &lt;br /&gt;
* Work on web services for the new automated EM Segmenter module (release Nov 10 - current). Verified task completion both for adult and pediatric images. Discussed tuning parameters for work load balance on workstations.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Started working on MRI registration to the reference CT scans. &lt;br /&gt;
* Design specs for optional White Matter segmentation for SUV computing.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* February 4, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipelines for Pediatric MRI (in progress)&lt;br /&gt;
* Adapting Pediatric T1 atlases for &amp;quot;Human Brain&amp;quot; build-in EM Segmentation wizard (in progress)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 28, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Verifying EM Segmenter module for latest builds and HIV/PED MS Studies (report pending)&lt;br /&gt;
* Work with SPECTRE module developers with pediatric MRI brainmask extraction&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* January 21, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Compiling plan for WF FrontEnd GUI migration to Slicer4/QT Widgets&lt;br /&gt;
* Preparing for annual progress report&lt;br /&gt;
&lt;br /&gt;
* January 14, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI: Integrated into the Slicer4 as Slicelet (or thin Client)&lt;br /&gt;
* Participation at AHM-2011, discussing integration of SPECTRE module and updated approach to EM-Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA&lt;br /&gt;
&lt;br /&gt;
* January 7, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* HIV project workflow delivered. Major additions relate to user convenience: &lt;br /&gt;
- Project-specific parameter settings, importing T1s and brainmasks from FreeSurfer outputs with conversion to NIFTI, resampling brainmask to original scans and automatied subject addition.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Follow up with end user: need to add MRI scans, if available, addition and registration to CT in order to ease VOI drawings.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
 &lt;br /&gt;
* December 31, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Follow-up with user Experience for AGING Study Segmentation (Positive feedback)&lt;br /&gt;
* Target date for HIV project delivery - next week&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Self-training for QT widget development&amp;lt;br&amp;gt;&lt;br /&gt;
* Outlined Workflow Rich Clients migration strategy from Java to QT/Slicer4:&amp;lt;br&amp;gt;&lt;br /&gt;
** Use Java Stubs (similar to SPECTRE integration) or file binding for envocation of workflow pipelines. (See SOAP remark below)&lt;br /&gt;
** Direct Web Servisec calls must be wrapped into REST protocol. The reason: NON-commerchial QT kit does not include SOAP protocol for web servises.&lt;br /&gt;
** The GUI will be implemented as page widget or QT dialog GUI forms called from within Slicer4.&lt;br /&gt;
** Communications between Slicer4 and WF GUI will be set via child-parent and signal-slot relations&lt;br /&gt;
* Worked on a Prototype for Basic EM Segmentation QT widget (70% complete). Will work on integrtion with SLicer4 during the AHM-2010&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
XNAT Integration&lt;br /&gt;
* Debugged XNAT RESTFul API usage for uplaoding DICOM series followed by header data extraction and image snapshots creation&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Added compensation for failed atlas registration (subject for old poor quality pseudo-T1 images): blank probability maps are created in case of failure.&lt;br /&gt;
* Data preparation module for FreeSurfer data import near completion. Expected time for deployment at end-users workstations - first week of January&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Discussed strategy for EM Segmentation pipeline solutions collection (K. Pohl, R. Kikinis)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* RE-using the same core workflow as for 1-channel EM Segmentation of AGING STUDY cases&lt;br /&gt;
* Added data input preparation module: ICC label mask preparation and skull-stripping based on FreeSurfer brainmask output volume.&lt;br /&gt;
* Two-channel EM segmentation pipeline (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE / GENERAL Development &amp;lt;br&amp;gt;&lt;br /&gt;
* Worked on plans for migrating fro rich workflow Java clients to embedded workflow windows inside the Slicer.&amp;lt;br&amp;gt;&lt;br /&gt;
The embedded workflow management clients are to be implemented with QT/PyQT toolkits&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
INTEGRATION WITH XNAT:&amp;lt;br&amp;gt;&lt;br /&gt;
* Automated DICOM series upload with triggering DICOM headers parsing at XNat site (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress. &lt;br /&gt;
- Results upload to XNat (Completed) &amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat based on user's input (Project + Subject + PET or CT session / scan) (Completed)&amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat - perfomance boosting solution for downloads found , web services services are created, relinking for the client side in progress &amp;lt;br&amp;gt;&lt;br /&gt;
- Xnat querying for subjects and automated subject addition into the workflow (In Progress) &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-segmentation module added for auto correction of segmentation results. Particularly - relabeling CSF voxels segmented as Air inside the intracranial cavity. This was requested by end-users after processing images with zero-signals in CSF voxels &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting automated dual-echo DICOM images conversion and split into two NRRD volumes&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT / EM Segmentation pipeline:&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting memory allocation issues for scull-stripping module SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
COPD Project:&amp;lt;br&amp;gt;&lt;br /&gt;
* Benchmark test for accelerated DICOM downloads from XNat (remoote XNat Central server): we can handle at least 6 cases (4 CT scans in each) per hour, which is compatible with current workload quotes on SPL cluster processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* December 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Deployed Version 1. &amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Test project chosen as a closest match to registration scenario: Pediatric MS Cases from MGH - requires periodic image preview for different &lt;br /&gt;
modalities taken from vaious time points. Label maps for VOIs resampling is also required.&lt;br /&gt;
&lt;br /&gt;
* November 26, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user. Version 1 is complete&amp;lt;br&amp;gt;&lt;br /&gt;
* Started working on integration with XNat&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on input data organizing modules&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 19, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user (70% done)&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Universal Registration Workflow for Longitudinal Studies - design specs in progress&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 12, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Minor tuning to EM Segmentation template as of users' feedback&lt;br /&gt;
* Users started using the workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed input data conversion from Genesis to Slicer native or NIFTI format. Our help may be needed in input data organizing.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Tuned application according to co-laborators (PNL) needs&amp;lt;br&amp;gt;&lt;br /&gt;
* The webservices and BPEL workflow application are tested ready to accept computation requests from PNL case tracking system &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Discussed Universal Registration Workflow for Longitudinal Studies&lt;br /&gt;
* Started the thread about possible cooperation with Children hospital's image processing pipelines and integration with Xnat &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 5, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Webservices and workflow pilot project created and deployed on Psychiatry Neuroimaging Laboratory subnet &amp;lt;br&amp;gt;&lt;br /&gt;
* The V.1.0 deployment is scheduled for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 29, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Most of functionality is completed. Some volume statistics post processing is pending&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL EM SEGMENTATION Pipeline: &amp;lt;br&amp;gt;&lt;br /&gt;
* The SPECTRE scull stripping module. Started integration into EMS workflow. Made some test runs from Slicer GUI&amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Identified as a candidate for Workflow Application&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 22, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* All back-end functionality are implemented&amp;lt;br&amp;gt;&lt;br /&gt;
* EM Segmentation scene usability is confirmed by end-user&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for next week: add Label Statistics computation for CSF/Brain/ICC &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 15, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* The latest (October) builds of Slicer 3.6.2 produced acceptable results. This was verified by the target users. The EM Segmentation will be performed on Slicer 3.6.2 or later&amp;lt;br&amp;gt;&lt;br /&gt;
* The new Web services had been created and added to the pipeline as optional processing steps: Biasfield correction (implement novel N2ITKBiasFieldCorrection module) and Volume's scalar datatype casting (as workaround for Biasfield correction module not preserving image scalar datatype - the bug is filed) &amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed the Front-End GUI design with target users. The design pattern is taken from the PETCT project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 8, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-deployment support. Tuned CT registration as of user's feedback.&lt;br /&gt;
* Adapting to the Single Slicer build: Slicer 3.6.2. Found label duplicates in the label lookup table - will ask user if it's tolerable. Waiting for the Slicer 3.6.2 build that contains all required modules. Rolling back label tag appending code for SUVs - the latest Slicer build appends the tags.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Resumed development. The priorities are set for usage of Slicer 3.6.2 - subject for EM Segmentation scene tuning. Continued coding for Scene creation for Slicer 2.8 - as a backup option for ongoing research project.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 1, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized V1.0 release based on end-user feedback: updates relate mostly to error proofing and SUV values representation&lt;br /&gt;
* Post-deployment support. Users pre-processed first set of patients &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* September 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* System deployed and tested at End Users' site.&amp;lt;br&amp;gt;Users are trained to perform all tasks required by the workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
* Got positive feedback with suggestions on Slicer Scenes' layouts improvement and PET scans' SUV (standard uptake values) results display&lt;br /&gt;
* Two distribution packages are assembled: Lunix and MAC OS versions. The difference in two packages is in specific Slicer3.6/3.7 builds - subject to Slicer Linux builds debugging.&amp;lt;br&amp;gt; As a workaround for Linux deployment - multiple Slicer builds are used to perform various tasks (registration, opening editing scenes in Slicer, SUV computing)&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for coming week - finalize V1.0 release based on end-user feedback&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Embedded SUV computations into the workflow (as system calls - will be translated into web service later)&amp;lt;br&amp;gt;&lt;br /&gt;
* Pre-release demo for end users.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Create and debug EM Segmenter scenes template for Slicer 3.6 and 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* September 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation - workflow pipeline and deployment verified&amp;lt;br&amp;gt;&lt;br /&gt;
* Tested EM Segmentation scenes within Slicer 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
* Started migration of EM Segmentation to Slicer 3.6. Discovered issues had been reported to EM Segmenter module designers &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* August 29 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation completed. Preprocessing Pipleine completed 80% (subject for input registration parameters tuning) &amp;lt;br&amp;gt;&lt;br /&gt;
* Most webservices (for registration and resampling steps) had been taken and re-used from PET/CT ROI/Longitudinal Study - showing the advantage of service-oriented software design and deployment.&lt;br /&gt;
* Continued on distribution and deployment of the service/workflow applications: on PET/CT and AGING STUDY projects.&lt;br /&gt;
&lt;br /&gt;
PEDIATRIC Multiple Sclerosis Cohort. Support of multi-center distributed processing project&amp;lt;br&amp;gt;&lt;br /&gt;
* Introduced Slicer 3.6 for the MS Lesion Assessment step performed at Mayo Clinic. Images are being transferred from image repository at BWH and automatically opened and arranged within Slicer GUI for reading.  This was replacement of Client GUI using MIPAV that stopped working on new computers at Mayo Clinic.&lt;br /&gt;
The images are being loaded via generated MRML Scenes same way as in PET/CT and AGING STUDY projects &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* August 22 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Preprocessing pipeline merge with SUV computations &amp;lt;br&amp;gt;&lt;br /&gt;
- QA for SUVs computation was performed by Wendy Plesniak for images with known uptake values. &amp;lt;br&amp;gt;&lt;br /&gt;
- Discovered that image cropping step (not related to automated registration pipeline and SUVs computing) smoothes the images by doing interpolation when used with default settings. Got suggestions from Steve Piper using Nearest-Neighbor interpolation (&amp;quot;no interpolation&amp;quot;) for a time being&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
- This is the new project candidate. Requested for the images with failed manual segmentation and/or segmentation with FreeSurfer. The EM Segmentation run showed most acceptable results on one of the problem images back in February &amp;lt;br&amp;gt;&lt;br /&gt;
- The workflow will be developed and deployed similar to PET/CT ROI Longitudinal study approach - all preprocessing steps will be done with Slicer modules, all runs will be performed on local end-user machines.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
 &lt;br /&gt;
&lt;br /&gt;
* August 15 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- First 5 cases with 3-4 time points preprocessed for SUVs computation&lt;br /&gt;
&lt;br /&gt;
* August 8 2010&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Testing of installation and operation at users' site (Performed by Wendy Plesniak)&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* July 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Delivered beta version of registration pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
- Prepared installation and user manuals &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* June 11, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Registration modules completed &amp;lt;br&amp;gt;&lt;br /&gt;
- Irregular cases registration problem solved (when whole body and brain only scans are mixed for a timepoint)&amp;lt;br&amp;gt;&lt;br /&gt;
- Live demo of case setup and registration workflow for end users. Real case with 4 timepoints used&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Coming week plans&amp;lt;br&amp;gt;&lt;br /&gt;
- Adjust workflow based on end users' feedback&amp;lt;br&amp;gt;&lt;br /&gt;
- Integration with SUVs computing for PET scans&amp;lt;br&amp;gt;&lt;br /&gt;
- GUI for workflows dispatching and data organizing&amp;lt;br&amp;gt;&lt;br /&gt;
- (TBD) Integration with 4D time series analysis Slicer module&amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
* May 28, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- Migration to the latest Slicer 3.6 release candidate &amp;lt;br&amp;gt;&lt;br /&gt;
- Added webservice for new registration module: BRAINSFit &amp;lt;br&amp;gt;&lt;br /&gt;
- Test runs for new patients with 4 timepoints' scans &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Plans for next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI &amp;lt;br&amp;gt;&lt;br /&gt;
- processing workflow demo for end user &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 21, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Pilot version of portable web services and automated workflow tested: &amp;lt;br&amp;gt;&lt;br /&gt;
Linux: workflow and visual review passed&amp;lt;br&amp;gt;&lt;br /&gt;
Stress test for 25 timepoints passed &amp;lt;br&amp;gt;&lt;br /&gt;
MAC OS: workflow passed, visual review failing when PET/CT images are loaded into GUI simultaneously (bug report submitted)&amp;lt;br&amp;gt;&lt;br /&gt;
Windows: need to adapt command line modules and workflow management system to sygwin environment&amp;lt;br&amp;gt;&lt;br /&gt;
Plans for next week: integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI&lt;br /&gt;
&lt;br /&gt;
* May 7, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Selected registration and resampling modules with more precise and stable outputs. &amp;lt;br&amp;gt;&lt;br /&gt;
Started building portable web services and automated workflow &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 30, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- manual walk through the processing steps: ROI cropping, registration/resampling, PET pharmaceutical DICOM data retention. &amp;lt;br&amp;gt;&lt;br /&gt;
- testing workflow and web services packages distribution to end-users' machines&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* April 23, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : testing various registration and re-sampling algorithms (work in progress)&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation: as of collaborators' request, run existing EM Segmentation workflow for older low resolution pseudo-T1 images. The EM Segmentation works for those images with manual sampling. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 16, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
  Social Cognition Study: started Cortical Thickness Measurement module build (bases on NA-MIC ARCTIC pipeline) &amp;lt;br&amp;gt;&lt;br /&gt;
  PET/CT ROI/Longitudinal Study Registration : Design specs, PET-to-CT images registration tests on training data. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 9, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. GUI update based on end-user experience.&amp;lt;br&amp;gt;&lt;br /&gt;
User request: automated label maps' volumes calculation (Currently possible from Slicer3 GUI)&amp;lt;br&amp;gt; &lt;br /&gt;
PET/CT ROI Project. Initial design specs discussion with end-users and co-developers&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure&lt;br /&gt;
Verification of segmentation workflow GUI: from registering new case to reviewing results&amp;lt;br&amp;gt;&lt;br /&gt;
Cross study test of segmentation workflow: MGH/MS Center data - success,  HIV Project data - some EM Segmentation scene tuning is needed &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*&lt;br /&gt;
* April 2, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. Segmentation workflow completed&amp;lt;br&amp;gt;&lt;br /&gt;
* Coming Week plans:&amp;lt;br&amp;gt;&lt;br /&gt;
- Document Segmentation Workflow. Follow up with end users &amp;lt;br&amp;gt;&lt;br /&gt;
- Start with Cortical Thickness and ROI-in-longitudinal studies workflows&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* March 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All essential processing and workflow interaction clients are ready.&amp;lt;br&amp;gt;&lt;br /&gt;
- Completed segmentation for 10 out of 50 patients. The remaining cases will be finalized upon manual lesion segmentation and QC verification of WM/GM/CSF and Deep GM segmentation's. &amp;lt;br&amp;gt;&lt;br /&gt;
- TODO next week: refine QC GUI and data tracking / progress monitoring schema. &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&amp;lt;br&amp;gt;&lt;br /&gt;
- New Slicer3 web services added: re-slicing with reference image volume, casting image scalar type &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
* March 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Segmentation maps Merging Services for GM/WM/CSF (Slicer EM Segemnter), Lesion (Slicer, Manual), and Deep GM (FreeSurfer)  &amp;lt;br&amp;gt;&lt;br /&gt;
- Deep GM segmentation pipeline adopted as optional service for Social Cognition Study (22 out of 50 cases processed) &amp;lt;br&amp;gt;&lt;br /&gt;
- (In progress) GUI client for Launching Segmentation results merging with optional Deep GM segmentation with FreeSurfer &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- Complete GUI Client for Segmentation result merging &amp;lt;br&amp;gt;&lt;br /&gt;
- Progress Monitoring services for entire Study processing: EM Segmenter Preprocessing, EM Segmentation, Lesion Segmentation (including human activities assignments), Deep GM segmentation, and results consolidation. &amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* March 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All 50 cases went through &amp;quot;basic&amp;quot; One-channel EM segmentation (GM/WM/CSF) &amp;lt;br&amp;gt;&lt;br /&gt;
- Basic pipeline start-up command line client created: user has two options - request brainmask extraction or provide with previously extracted brainmask for a given subject &amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison of GM/WN/CSF performed for Slicer EM Segmenter and FreeSurfer recon-all (used with default settings). &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmenter provides more accurate output &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmentation pipeline runs faster (40 minutes vs 12 hrs when no brainmask extraction requested) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO:&amp;lt;br&amp;gt;&lt;br /&gt;
- merging modules for automatic 1-channel EM segmentation and manual lesion segmentation &amp;lt;br&amp;gt;&lt;br /&gt;
- Emerge Cortical Thickness pipeline project: use NAC ARCTIC processing steps and modules &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Selected stable EM Segmentation scenario: White Matter, Gray Matter, and Cerebrospinal Fluid &amp;lt;br&amp;gt;&lt;br /&gt;
- First 16 cases are segmented for selected scenario. Nine more cases are preprocessed for EM Segmentation.&amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison to segmentation with FreeSurfer showed better accuracy for Slicer2 EMSegmenter &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure &amp;lt;br&amp;gt;&lt;br /&gt;
- Three prerpcocessed cases failed during volume ICC masking with in-house build utility. Evaluated switching to Slicer3 Mask and island removing modules.&amp;lt;br&amp;gt;&lt;br /&gt;
- Initial design specs discussion for cortical thickness measurement pipeline. ARCTIC pipeline selected. ARCTIC preprocessing steps signifficantly overlap with EM Segmentation preprocessing workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
  &lt;br /&gt;
* February 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: &amp;lt;br&amp;gt;&lt;br /&gt;
A) parameters tuning for EM Segmenter itself (work with EM Segmenter developer), template scenes creation &amp;lt;br&amp;gt;&lt;br /&gt;
B) update preprocessing pipeline - deep gray matter atlases included &amp;lt;br&amp;gt;&lt;br /&gt;
C) test and debug preprocesing pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
D) identified missing modules: atlas autocalibration for EM Segmentation scene, Island removal for ICC mask&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- Review currently deployed modules. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: reviewed firts seven subjects' outputs, added volume orientation module into pipeline (prevents ICBM atlas linear registration failures)&amp;lt;br&amp;gt;&lt;br /&gt;
- Fused ICC(brainmask) extraction module with EM Segmenter preprocessing. Three scenarious implemented: start with pre-extracted ICC mask (longitudinal studies case), run with ICC ectration, run with ICC extraction AND ICC correction before ICBM atlas preporcessing. &amp;lt;br&amp;gt;&lt;br /&gt;
- Completion of Human activities GUI (QC, ICC Correction) planned for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: Volume Orientation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: automated preprocessing pipeline for Slicer2 EM Segmenter test version deployed. Seven cases pre-processed.&lt;br /&gt;
- PET Quantitative measurements: Preliminary design specs discussion.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: BSplineRegistration (for non-linear registration), ResampleVolume2 (for atlases resampling based on image atlase templates registration). Local and Network runs are implemented, Cluster/GridWizard implementation pending.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Slicer EM Segmenter module: preprocessing design for Slicer2 EM Segmenter&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Adapting for Slicer2 EM Segmenter (mostly from pipelines and services for previous projects)&lt;br /&gt;
  -- Integration with FreeSurfer modules for bisafield correction, brainmask extraction, and linear registration of ICBM atlases&lt;br /&gt;
  -- Preprocessing updates for non-linear registration of ICBM atlases with Slicer2 (image re-orientation service designed)&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 29, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- EM Segmentaton pipeline: preprocessing results are being transferred to XNat (anonymized data, Central XNat) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Slicer EM Segmenter module: discussed agenda and scheduled a work meeting for Social Cognition Study image segmentation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Testing stage, 95% completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- SPL XNat server: verified data exchange via RESTfull web services.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 22, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Follow up with White Matter Lesion Segmenter and Scull Stripping Modules developers: Work in Progress&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Work in Progress, 60%+ completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Discussed SPINE image repository migration to XNat&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 15, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. &lt;br /&gt;
- Social Cognition Study: &lt;br /&gt;
Work-in-progress on intermediate (reconstruction) and results (resources) data storage at XNat.&lt;br /&gt;
&amp;lt;br&amp;gt;Reviewing and preparation more cases for EM Segmentor (Slicer 3.5) tuning.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* NA-MIC Project Week&lt;br /&gt;
Selecting candidate Slicer modules for other than Lesion EM Segmentation topics of Social Cognition study: Withe Matter Lesion Segmenter (UNC), Scull Stripping utility from UIOWA.&lt;br /&gt;
Reviewing issues of currently used Scull Stripping Slicer Extension and Slicer 3.5 EM Segmenter.&lt;br /&gt;
&amp;lt;br&amp;gt;XNat Data organizing training&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 1, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Preparation of Demo for NA-MIC work week: &lt;br /&gt;
- COPD Study. Added Remote pipepline start interface (represents real world scenario where Xnat repository, Processing modules and User are at different sites)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
- EM Segmentation. Added human activities steps to the workflow: ICC (brainmask) correction and EM Segmantation scena load per se.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 25, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Pilot workflow pipeline for EM Segmentation (all steps except user-activity step: ICC correction assignment and tracking)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 18, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Build and tested web services for EM Segmentation image preprocessing: DICOM-to-NRRD conversion, registration, skull stripping, image masking.&lt;br /&gt;
Started building workflow pipeline (subject to finish first version next week)&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Started Collecting Library of Slicer Build number vs. functional modules and extensions.&lt;br /&gt;
Plan for NAMIC project week: scheduled meetings for XNat data customization, Skull-stripping modules tuning, identified Social Cognition study cases that fail EM Segmentation processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 11, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Updating and verification of EM Segmentation Scenario&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Projects:ARRA:SlicerWF:UseCaseScenarios#Usecase_MS_lesion_Assessment&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Familiarizing with Slicer3.4/5 Modules required for implementation of EM Segmentation Scenario. Participation in debugging and/or usage tuning of Dicom Conversion, Registration, Skull Stripping, Masking, and Image Casting modules. &lt;br /&gt;
&lt;br /&gt;
* December 4, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Slicer3.4's EM Segmentation and Visual QC as part of image processing pipeline for Social Cognition Study for MS Patients.&lt;br /&gt;
Project emerged. EM Segmentation template creation debugged.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
Emphysema Measurements (COPD Study) - workflow stability and scalability test.&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 27, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Emphysema Measurements (COPD Study).&lt;br /&gt;
Added compensation for long running calculations and time-outs to the main computing pipeline.&lt;br /&gt;
Visual QC (work in progress)&lt;br /&gt;
** Infrastructure&lt;br /&gt;
XNat data structure customization, metadata storage, results consolidation: new feature request list creation (work in progress)&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 13, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
*** Pilot system for whole processing cycle for Emphysema Measurements (COPD Study) including the following:&lt;br /&gt;
Web query for CT session file list download&lt;br /&gt;
Pilot user interface for submitting the file list and starting processing pipeline&lt;br /&gt;
Notification about processing steps and failures&lt;br /&gt;
Upload results to XNat repository (at this stage results are uploaded into same folder where original scans are(*))&lt;br /&gt;
*** Immediate Plans&lt;br /&gt;
Complete Visual QC module&lt;br /&gt;
Design and implement meta-data transfer to XNat (including processing details and MRML files for loading images into the 3D Slicer)&lt;br /&gt;
&lt;br /&gt;
(*)Customization of results storage&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 6, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Tuned and debugged multiple subjects processing for: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat.&lt;br /&gt;
***Started working on quality control embedding into the above scenario. Plan to complete and video-record demo next week.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***Published general Product Integration scenario flow chart to collaborators' community. Discussion is open and in progress&lt;br /&gt;
&lt;br /&gt;
* October 30, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Piloted and tested the sequence: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat(1).&lt;br /&gt;
***Performance test of overall cycle: data transfer from remote serve is a bottleneck as expected&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data browsing features reviewed.&lt;br /&gt;
(1) Not automated yet&lt;br /&gt;
* October 23, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Defined COPD processing scenario with interoperability between Xnat, 3D Slicer Command Modules, Workflow, and Gridwizard Enterprise.&lt;br /&gt;
***Pilot version of Emphysema Measurements workflow pipeline deployed.&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data transfer features reviewed. Use account at XNat Central during learning curve.&lt;br /&gt;
***Feasibility test of 3D Slicer fiducials module for ROI highlights during QC and manual image processing activities. &lt;br /&gt;
* October 16, 2009&lt;br /&gt;
**Lung CT Scans Processing. Pilot project emerged. GenerateEmphysemaMeasurements module deployed as a webservice that submits jobs to computational cluster.&lt;br /&gt;
**EM Segmentation. Familiarized with GUI steps. Started working on automation steps outlining&lt;br /&gt;
**3D Slicer and XNat interaction. Got an overview from Wendy Plesniak.&lt;br /&gt;
* October 1 - 7, 2009&lt;br /&gt;
**Selected two first priority Projects: EM Segmentation of brain MRI images; Lung CT Scans Processing (COPD Study)&lt;br /&gt;
**Got initial outline of user requirements and design specs&lt;/div&gt;</summary>
		<author><name>Azaitsev</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=67067</id>
		<title>Projects:ARRA:SlicerWF</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=67067"/>
		<updated>2011-05-09T00:36:43Z</updated>

		<summary type="html">&lt;p&gt;Azaitsev: /* Progress */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Projects:ARRASuplements|Back to Slicer ARRA home page]]&lt;br /&gt;
= Aim =&lt;br /&gt;
Supplement 3D Slicer and Extensible Neuroimaging Archive Toolkit (XNAT) with workflow management system. Provide integration and interoperability between 3D Slicer, XNAT Services and 3-rd party image processing applications and high performance computing systems. Implement it as within currently developed Structural Planning and Implementation in Neurological Exploration (SPINE) System.&lt;br /&gt;
&lt;br /&gt;
= SPINE Project Documentation =&lt;br /&gt;
[http://cni.bwh.harvard.edu/projects/spine/index.html SPINE Docs]&lt;br /&gt;
&lt;br /&gt;
= Presentations =&lt;br /&gt;
* Segmentation Workflow. PECS University Social Cognition Study.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:SlicerWF_NAC_PECS_Workflow.pdf]]&lt;br /&gt;
* EAB10_ARRA Annual Progress Report Slides.&amp;lt;br&amp;gt;&lt;br /&gt;
[[media:EAB10_ARRA_WF_2011_Zaitsev.ppt | Service Oriented Solutions for 3D Slicer. EAB10_ARRA_WF_2011. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:EAB10_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:NAMIC_ARRA_WF_2011_Zaitsev.ppt  | NAMIC Annual Report 04/2010-03/2011. NAMIC_ARRA_WF_2011_Zaitsev. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:NAMIC_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:Slicer_WF_Slicer4CARMAWorkflow.ppt  | CARMA Workflow. Cardiac Ablation Followup. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:Slicer_WF_Slicer4CARMAWorkflow.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* CARMA Project Beta release Demo Location: http://cni29.bwh.harvard.edu/SlicerWFDemo/index.php&lt;br /&gt;
&lt;br /&gt;
* Segmentation Workflows: Screenshots, scans' and study description : [[File:SlicerWF_EMSegmentProjectsReview.zip]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
= All Hands Meeting Pages =&lt;br /&gt;
* Salt Lake City 2011 Winter [http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA SLC_2011_WorkFlow]&lt;br /&gt;
* MIT 2010 Summer [http://wiki.na-mic.org/Wiki/index.php/Summer_project_week_2010_Workflows_SOA MIT_2010_WorkFlow]&lt;br /&gt;
&lt;br /&gt;
= Research Plan =&lt;br /&gt;
*Create a stand-alone SPINE desktop agent with fully functional data exchange and communication mechanisms towards 3D Slicer and XNAT.&lt;br /&gt;
*Develop Service Oriented Architecture (SOA) SPINE System that will include 3D Slicer image processing modules deployed as web services as well as a workflow management system to orchestrate interaction between 3D Slicer, XNAT, and 3-rd party tools.&lt;br /&gt;
*Implement two-way control and communications between 3D Slicer and SPINE modules.&lt;br /&gt;
*Adapt SPINE System for cluster and grid computing scenarios.&lt;br /&gt;
*Provide with workflow and 3D Slicer web service wrappers editing tools.&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:UseCaseScenarios| Use Case scenarios]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PETCTWorkflow| PETCTWorkflow]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:AgingStudySegmentation| AgingStudySegmentation]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:TwoTensorTractography| TwoTensorTractography]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:LongitudinalMultimodalityRegistrationSuite| LongitudinalMultimodalityRegistrationSuite]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:MigrationJavaClients2QT| MigrationJavaClients2QT]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PediatricMSSegmentation| PediatricMSSegmentation]]&lt;br /&gt;
*[[DBP3:Utah:RegSegPipeline| MRI-based study and treatment of atrial fibrillation]]&lt;br /&gt;
&lt;br /&gt;
= Application Server / Workflow Engine Downloads =&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:WFEngineDownloads| Download Links]]&lt;br /&gt;
&lt;br /&gt;
=Key Personnel=&lt;br /&gt;
* Charles Gutmann, MD., 4%,  9-17-2009 through 9-16-2011&lt;br /&gt;
* Alexander Zaitsev, Ph.D., 75%, 9-17-2009 through 9-16-2011 &lt;br /&gt;
&lt;br /&gt;
=Annual Progress Statements =&lt;br /&gt;
'''2010-11''' &amp;lt;br&amp;gt;&lt;br /&gt;
The  April 2011 – March 2011 period was devoted on developing portable workflow solutions that can be deployed on end-users' workstations or notebooks with minimal or no system administration activities. This is in contrast to the server-side deployment. The following scenarios had been deployed and used for actual projects that require the following types of workflows: PET/CT registration and computation of biomarker driven brain physiological activities, Brain MRI Images segmentation,  MRI and MRI Angiography images pre-processing for cardiac ablation outcome estimation. Some  workflows (like EM Segmentation) had been utilizing various scenarios, some research projects  (like evaluation of chemotherapy outcome) require two types of workflows to assess physiological and structural changes. Starting from the 4th Quarter of 2011, the migration project had been emerged in order to embed Workflow GUIs into newly developed Slicer4 Suite. The existing rich client Java GUI applications are being re-written as C++/QT Sliceletts units, new modules (such as cardiac ablation project support) are had been written from scratch. The latter are being deployed from the Slicer4 GUI and act at a liaison between Slicer4 and Application Server containing  workflow and Slicer modules deployed as services. The feedback from the end users indicates that Workflow approach for the complex processing improves productivity, aids to the processing standardization and contributes to the overall experience using 3D Slicer&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
=Quarterly Progress=&lt;br /&gt;
&lt;br /&gt;
* NAMIC Annual Progress Slides (April 2010 - March 2011):&lt;br /&gt;
&lt;br /&gt;
* '''1st Qtr, 2011''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study: Second release is under testing by end-users. &lt;br /&gt;
*** Added MRI registration to aid ROI drawing on PET scans&lt;br /&gt;
*** Improved SUV results reporting and added flexibility to update ROI lookup table&lt;br /&gt;
*** Automated EM Segmentation of MRI images for computing SUVs for white matter, CSF, and whole brain (80% completion)&lt;br /&gt;
*** Integration with SPECTRE scull stripping module (70% completion) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** EM Segmentation: Automated WF Pipelines are created &amp;lt;br&amp;gt;&lt;br /&gt;
*** Flexible atlas selection (Pediatric, etc) feature added&lt;br /&gt;
*** Workflows implemented for EM Segmenter 3.6.2 and 3.6.3 (1st Qtr 2011 release)&lt;br /&gt;
&lt;br /&gt;
** Cardiac ablation results follow-up: Workflow for registration and ROI selection of cardiac MRI and MR Angiography &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Wrokflow and Web Services for prospective DTI tractography modules (currently written as Matlab modules at PNL) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Web Services for SPECTRE Scull stripping module&lt;br /&gt;
*** Accuracy and performance tuning&lt;br /&gt;
*** 50% completion&lt;br /&gt;
&lt;br /&gt;
** Migration Front End GUI to Slicer4/QT:&lt;br /&gt;
*** EM Segmentation&lt;br /&gt;
*** Cardiac Ablation Study&lt;br /&gt;
&lt;br /&gt;
** DICOM Uploader and Desktop Browser for XNat Image repository (alpha version - tested for MGH MS Center studies, proposed to use with MI2B2 Clients and Services)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''4th Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study and EM Segmentation for Aging Study are deployed at end-user sites and actively used for research. &lt;br /&gt;
** Adopted EM Segmentation preprocessing pipeline for HIV Study: high resolution SPGR images, integration with FreeSurfer brainmask extraction outputs; integration of Slicer SPECTRE module for brainmask extraction is in progress.&lt;br /&gt;
** The following post-release upgrades had been implemented based on end-user feedback: Application Server basic controls are performed from Rich Client GUI as alternative to traditional IT administration activities. The controls are implemented on point-and-click bases and include web services and workflow application deployment and upgrades, application server start and stop as well as warning end user when the server is not accepting request.&lt;br /&gt;
** Added DICOM downloads and results uploads of PET/CT pipelines from and to XNat Repository&lt;br /&gt;
** Created Services and Workflow for Matlab Prototypes modules. Case Study: tractography for DTI images&lt;br /&gt;
** Extended XNAT integration services:&lt;br /&gt;
*** Browsing capabilities of XNat data repository from the Workflow Applications&lt;br /&gt;
*** Improved DICOM upload and download performance&lt;br /&gt;
*** Added Metadata organizing services for uploaded DICOM images: header data extraction, image snapshots creation. &lt;br /&gt;
** Started project for Rich Client GUI migration from Java desktop application to build into SLicer4 QT modules. This affects mostly front-end GUI and has the following approaches: distribution with the Slicer4, end-user will select desired workflow application from Slicer4 menu while QT-written modules provide with the same functionality as Java Rich Clients. Case Study for the Migration process: registration suite for longitudinal studies that include multi-modality images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* '''3d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Concentrated on building downloadable workflow applications that could run both in desktop (new) and server environment, and that require minimum IT administrative resources. The desktop deployment is in compliance with Slicer3 general deployment concept.&lt;br /&gt;
*** The following use case scenario had been chosen: PET/CT image processing for longitudinal studies, EM Segmentation for longitudinal Aging Study.&lt;br /&gt;
** Released workflow application for PET/CT image processing for longitudinal studies. Provided end users with training and documentation.&lt;br /&gt;
*** The PET/CT processing workflow was designed to be a general application used whenever both structural patterns and metabolic activities are within the research scope. &lt;br /&gt;
*** The desktop version is tuned to use minimal computer resources, so the automates processing instances do not interfere with human activities. Automated activities may include, for example, registration and PET scan's standard uptake values computing, and manual human activities may include image cropping, quality control, and labeling voxels of interest.&lt;br /&gt;
** Core services and EM Segmentation preprocessing workflow was build for retrospective Aging Study. Tuned the Slicer3 webservices for processing low grade images acquired in mid 90s. Entire workflow is implemented with Slicer3 only modules and can be deployed locally and on the servers. Usage of Service Oriented Architecture (SOA) as a core technological approach allowed reusing most of the web services that had been build for PET/CT project. &lt;br /&gt;
** Continued embedding Slicer3 application and modules into previously released processing pipelines: replaced MIPAV with Slicer3 GUI for lesion assessment step in the multi-center Pediatric MS Cohort image processing &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''2d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Completed Social Cognition Workflow Implementation. This includes EM Segmetnation pre- and post-processing pipelines, data tracking, and integration with 3d party image processing utilities, as well as processing results acquired manually with Slicer GUI.  &lt;br /&gt;
** Multi-modality image registration and ROI selection/alignment workflow for longitudinal studies. &lt;br /&gt;
*** Use case: PET/CT image processing for longitudinal studies. &lt;br /&gt;
*** Build portable library of Slicer modules as web services and workflow that are deployed and run on a end-users' worksatations without utilization of SPL and other servers. The web services include novel Slicer3 modules, such as BRAINSFit and BRAINSResamle &lt;br /&gt;
*** Started working with Slicer3 developers on Slicer 3.8 GUI wizard to communicate with workflow instances.&lt;br /&gt;
** Participated at NA-MIC Summer 2010 Project Week: [[Summer_project_week_2010_Workflows_SOA]]&lt;br /&gt;
&lt;br /&gt;
=Progress=&lt;br /&gt;
* May 6, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Removing Java web service stubs via creation of RESTFul web service wrappers for workflow instances (SOAP) on application server (work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (QA of EM Segmenter module, work in progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* April 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Open Discussion for Packaging WF QT Modules as Slicer4 extensions (waiting for SOPs)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review supported projects http://wiki.na-mic.org/Wiki/index.php/File:SlicerWF_EMSegmentProjectsReview.zip &lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (required by Study)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Slicer Modules General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Standardizing Crop Volumes Output (with A. Fedorov's module). Review for required updates of existing product (PET/CT, CARMA)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Open Discussion for Packaging WF QT Modules as Slicer4 extensions (waiting for SOPs)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review supported projects http://wiki.na-mic.org/Wiki/index.php/File:SlicerWF_EMSegmentProjectsReview.zip &lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (required by Study)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Slicer Modules General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Standardizing Crop Volumes Output (with A. Fedorov's module)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 22, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Beta release ready. Demo Location: http://cni29.bwh.harvard.edu/SlicerWFDemo/index.php&lt;br /&gt;
* TODO: Tutorial. Original inputs copy/renaming&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 15, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Adding App server auto-config features&lt;br /&gt;
* Finalizing the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 08, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Second release beta build tested on cosutmer side &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review registration quality (with Dr. Meier). Angiography images' Resampling tuned. &lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 01, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the second release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
XNat Integration&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* (Java) GUI for Project Browsing and DICOM Series Upload. Post-upload DICOM processing tested and debugged&amp;lt;br&amp;gt;&lt;br /&gt;
* Ready for integration with mi2b2 client.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Migrated to Latest Slicer 3.6.3 stable release: only the Input scene had to be updated, the API remained the same&lt;br /&gt;
* Tested EM Segmenter with CMTK4Slicer extension - processing takes to much time on Linux_64bit machine, rolled back to BRAINSFit registration. When used on Mac OS X build, the Slicer could not start (bug report 1126).&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SPECTRE Scull Stripping:&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Testes for various use cases: the module is extremely sensitive to T1 MRI quality (does not work for most MRIs from PET/CT project&lt;br /&gt;
* TODO next week: check for FLAIR images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Slicer4 QT GUI and Cropping activity in progress.&amp;lt;br&amp;gt;&lt;br /&gt;
* Tried direct MRA to MRA registration option: resampling with LMRI registration transforms works better.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Extra VOI labels revised&lt;br /&gt;
* Debugging of SUV results' renormalization step&lt;br /&gt;
* TODO: ICC extraction / whole brain total uptake computing; EM Segmentation for R_WM, L_WM SUV computing and BPH estimation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SCULL STRIPPING/SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Installed and tested CLI option on Linux_64bit platform&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Workflow interruption before BSPline registraton: BPEL Module completed. Slicer4 QT GUI and Cropping activity in prorgess.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Implemented and Tested with end-users proposed changes: denormalization of SUV results, adding more VOI labels, added FLAIR MRI in addition to T1s for VOI drawing&lt;br /&gt;
* Tested manual ICC extraction using PET scans: works satisfactory with island removal and cropping followed by threshold level labeling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4&lt;br /&gt;
* Change proposed: interrupt workflow after affine registration and have user crop the VOI. This is to prevent excessive deformations for BSpline registration and resampling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4. User has option to choose the atlas that fits better for the given subject (NOTE: hardcoding must be rewritten for atlas linking)&lt;br /&gt;
* PETCT test - the problem is that T1s are low resolution and with contrast. Proposed using T1s without contrast&lt;br /&gt;
* PETCT change request: users wants to compute SUV for entire ICC. Had demo how to segment brainmask/ICC using PET scan. The derived brainmask label can be used for SUV computation.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - cmpleted&lt;br /&gt;
* Sample cases run - excessive deformation after BSpline registration hase&lt;br /&gt;
* Next week plan - pull tuning controls to front-end of pipeline API, start working of QT module for CARMA registration&lt;br /&gt;
* May consider other than BRAINSFit registration modules&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Design plan for change request: more VOI labels, add FLAIR in addition to T1 for VOI drawing, T1s segmentation&lt;br /&gt;
* Tested segmentation for sample cases - artifacts from poor quality MRIs lead to exclusion of parts of ICC from segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Completed troubleshooting of EMSegmenter module calling from Java (need TCL libs to be pulled from Slicer environment)&lt;br /&gt;
* Tested EMSegmenter autoruns for HIV and Pediatric MS patiens. Work as expected, subject to improvement of PED MS case segmentation by building better skull/neck/air atalses&lt;br /&gt;
* Suggested usage of two subsets of atalases: with and without neck. The Subject MRIs have to be cropped accordingly or best fit atlas has to be selected&lt;br /&gt;
* Made no-neck cropped atlas collection for default EMSegmenter scenario&lt;br /&gt;
* Tested with PET/CT study MRI cases - see above &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - in progress&lt;br /&gt;
* Next week goal - have back end processing ready&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Longitudinal Study&lt;br /&gt;
* Added MRI registration to the pipeline&lt;br /&gt;
* Troubleshooting of complex XML schema issues on Linux machines (some modules working on MAC do not work on Linux). As a workaround - did not include MRI convert and register part into base BPEL module. Used separate services (transparent for end-user)&lt;br /&gt;
* TODO next week for change request completion: explicit pixel type casting for MRI in BRAINSFit, VOI MRML scene update (currently MRI added on top of schema)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* February 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipeline for Pediatric MRI. Same scenario as for HIV Project, icbm pediatric atlases (Completed, verified)&lt;br /&gt;
* Collected NIH healthy brain development atlases: various age ranges from 4.5 to 18 yo. Converted to Slicer readable format &lt;br /&gt;
* Work on web services for the new automated EM Segmenter module (release Nov 10 - current). Verified task completion both for adult and pediatric images. Discussed tuning parameters for work load balance on workstations.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Started working on MRI registration to the reference CT scans. &lt;br /&gt;
* Design specs for optional White Matter segmentation for SUV computing.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* February 4, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipelines for Pediatric MRI (in progress)&lt;br /&gt;
* Adapting Pediatric T1 atlases for &amp;quot;Human Brain&amp;quot; build-in EM Segmentation wizard (in progress)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 28, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Verifying EM Segmenter module for latest builds and HIV/PED MS Studies (report pending)&lt;br /&gt;
* Work with SPECTRE module developers with pediatric MRI brainmask extraction&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* January 21, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Compiling plan for WF FrontEnd GUI migration to Slicer4/QT Widgets&lt;br /&gt;
* Preparing for annual progress report&lt;br /&gt;
&lt;br /&gt;
* January 14, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI: Integrated into the Slicer4 as Slicelet (or thin Client)&lt;br /&gt;
* Participation at AHM-2011, discussing integration of SPECTRE module and updated approach to EM-Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA&lt;br /&gt;
&lt;br /&gt;
* January 7, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* HIV project workflow delivered. Major additions relate to user convenience: &lt;br /&gt;
- Project-specific parameter settings, importing T1s and brainmasks from FreeSurfer outputs with conversion to NIFTI, resampling brainmask to original scans and automatied subject addition.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Follow up with end user: need to add MRI scans, if available, addition and registration to CT in order to ease VOI drawings.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
 &lt;br /&gt;
* December 31, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Follow-up with user Experience for AGING Study Segmentation (Positive feedback)&lt;br /&gt;
* Target date for HIV project delivery - next week&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Self-training for QT widget development&amp;lt;br&amp;gt;&lt;br /&gt;
* Outlined Workflow Rich Clients migration strategy from Java to QT/Slicer4:&amp;lt;br&amp;gt;&lt;br /&gt;
** Use Java Stubs (similar to SPECTRE integration) or file binding for envocation of workflow pipelines. (See SOAP remark below)&lt;br /&gt;
** Direct Web Servisec calls must be wrapped into REST protocol. The reason: NON-commerchial QT kit does not include SOAP protocol for web servises.&lt;br /&gt;
** The GUI will be implemented as page widget or QT dialog GUI forms called from within Slicer4.&lt;br /&gt;
** Communications between Slicer4 and WF GUI will be set via child-parent and signal-slot relations&lt;br /&gt;
* Worked on a Prototype for Basic EM Segmentation QT widget (70% complete). Will work on integrtion with SLicer4 during the AHM-2010&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
XNAT Integration&lt;br /&gt;
* Debugged XNAT RESTFul API usage for uplaoding DICOM series followed by header data extraction and image snapshots creation&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Added compensation for failed atlas registration (subject for old poor quality pseudo-T1 images): blank probability maps are created in case of failure.&lt;br /&gt;
* Data preparation module for FreeSurfer data import near completion. Expected time for deployment at end-users workstations - first week of January&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Discussed strategy for EM Segmentation pipeline solutions collection (K. Pohl, R. Kikinis)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* RE-using the same core workflow as for 1-channel EM Segmentation of AGING STUDY cases&lt;br /&gt;
* Added data input preparation module: ICC label mask preparation and skull-stripping based on FreeSurfer brainmask output volume.&lt;br /&gt;
* Two-channel EM segmentation pipeline (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE / GENERAL Development &amp;lt;br&amp;gt;&lt;br /&gt;
* Worked on plans for migrating fro rich workflow Java clients to embedded workflow windows inside the Slicer.&amp;lt;br&amp;gt;&lt;br /&gt;
The embedded workflow management clients are to be implemented with QT/PyQT toolkits&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
INTEGRATION WITH XNAT:&amp;lt;br&amp;gt;&lt;br /&gt;
* Automated DICOM series upload with triggering DICOM headers parsing at XNat site (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress. &lt;br /&gt;
- Results upload to XNat (Completed) &amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat based on user's input (Project + Subject + PET or CT session / scan) (Completed)&amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat - perfomance boosting solution for downloads found , web services services are created, relinking for the client side in progress &amp;lt;br&amp;gt;&lt;br /&gt;
- Xnat querying for subjects and automated subject addition into the workflow (In Progress) &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-segmentation module added for auto correction of segmentation results. Particularly - relabeling CSF voxels segmented as Air inside the intracranial cavity. This was requested by end-users after processing images with zero-signals in CSF voxels &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting automated dual-echo DICOM images conversion and split into two NRRD volumes&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT / EM Segmentation pipeline:&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting memory allocation issues for scull-stripping module SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
COPD Project:&amp;lt;br&amp;gt;&lt;br /&gt;
* Benchmark test for accelerated DICOM downloads from XNat (remoote XNat Central server): we can handle at least 6 cases (4 CT scans in each) per hour, which is compatible with current workload quotes on SPL cluster processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* December 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Deployed Version 1. &amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Test project chosen as a closest match to registration scenario: Pediatric MS Cases from MGH - requires periodic image preview for different &lt;br /&gt;
modalities taken from vaious time points. Label maps for VOIs resampling is also required.&lt;br /&gt;
&lt;br /&gt;
* November 26, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user. Version 1 is complete&amp;lt;br&amp;gt;&lt;br /&gt;
* Started working on integration with XNat&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on input data organizing modules&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 19, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user (70% done)&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Universal Registration Workflow for Longitudinal Studies - design specs in progress&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 12, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Minor tuning to EM Segmentation template as of users' feedback&lt;br /&gt;
* Users started using the workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed input data conversion from Genesis to Slicer native or NIFTI format. Our help may be needed in input data organizing.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Tuned application according to co-laborators (PNL) needs&amp;lt;br&amp;gt;&lt;br /&gt;
* The webservices and BPEL workflow application are tested ready to accept computation requests from PNL case tracking system &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Discussed Universal Registration Workflow for Longitudinal Studies&lt;br /&gt;
* Started the thread about possible cooperation with Children hospital's image processing pipelines and integration with Xnat &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 5, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Webservices and workflow pilot project created and deployed on Psychiatry Neuroimaging Laboratory subnet &amp;lt;br&amp;gt;&lt;br /&gt;
* The V.1.0 deployment is scheduled for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 29, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Most of functionality is completed. Some volume statistics post processing is pending&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL EM SEGMENTATION Pipeline: &amp;lt;br&amp;gt;&lt;br /&gt;
* The SPECTRE scull stripping module. Started integration into EMS workflow. Made some test runs from Slicer GUI&amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Identified as a candidate for Workflow Application&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 22, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* All back-end functionality are implemented&amp;lt;br&amp;gt;&lt;br /&gt;
* EM Segmentation scene usability is confirmed by end-user&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for next week: add Label Statistics computation for CSF/Brain/ICC &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 15, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* The latest (October) builds of Slicer 3.6.2 produced acceptable results. This was verified by the target users. The EM Segmentation will be performed on Slicer 3.6.2 or later&amp;lt;br&amp;gt;&lt;br /&gt;
* The new Web services had been created and added to the pipeline as optional processing steps: Biasfield correction (implement novel N2ITKBiasFieldCorrection module) and Volume's scalar datatype casting (as workaround for Biasfield correction module not preserving image scalar datatype - the bug is filed) &amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed the Front-End GUI design with target users. The design pattern is taken from the PETCT project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 8, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-deployment support. Tuned CT registration as of user's feedback.&lt;br /&gt;
* Adapting to the Single Slicer build: Slicer 3.6.2. Found label duplicates in the label lookup table - will ask user if it's tolerable. Waiting for the Slicer 3.6.2 build that contains all required modules. Rolling back label tag appending code for SUVs - the latest Slicer build appends the tags.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Resumed development. The priorities are set for usage of Slicer 3.6.2 - subject for EM Segmentation scene tuning. Continued coding for Scene creation for Slicer 2.8 - as a backup option for ongoing research project.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 1, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized V1.0 release based on end-user feedback: updates relate mostly to error proofing and SUV values representation&lt;br /&gt;
* Post-deployment support. Users pre-processed first set of patients &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* September 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* System deployed and tested at End Users' site.&amp;lt;br&amp;gt;Users are trained to perform all tasks required by the workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
* Got positive feedback with suggestions on Slicer Scenes' layouts improvement and PET scans' SUV (standard uptake values) results display&lt;br /&gt;
* Two distribution packages are assembled: Lunix and MAC OS versions. The difference in two packages is in specific Slicer3.6/3.7 builds - subject to Slicer Linux builds debugging.&amp;lt;br&amp;gt; As a workaround for Linux deployment - multiple Slicer builds are used to perform various tasks (registration, opening editing scenes in Slicer, SUV computing)&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for coming week - finalize V1.0 release based on end-user feedback&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Embedded SUV computations into the workflow (as system calls - will be translated into web service later)&amp;lt;br&amp;gt;&lt;br /&gt;
* Pre-release demo for end users.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Create and debug EM Segmenter scenes template for Slicer 3.6 and 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* September 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation - workflow pipeline and deployment verified&amp;lt;br&amp;gt;&lt;br /&gt;
* Tested EM Segmentation scenes within Slicer 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
* Started migration of EM Segmentation to Slicer 3.6. Discovered issues had been reported to EM Segmenter module designers &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* August 29 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation completed. Preprocessing Pipleine completed 80% (subject for input registration parameters tuning) &amp;lt;br&amp;gt;&lt;br /&gt;
* Most webservices (for registration and resampling steps) had been taken and re-used from PET/CT ROI/Longitudinal Study - showing the advantage of service-oriented software design and deployment.&lt;br /&gt;
* Continued on distribution and deployment of the service/workflow applications: on PET/CT and AGING STUDY projects.&lt;br /&gt;
&lt;br /&gt;
PEDIATRIC Multiple Sclerosis Cohort. Support of multi-center distributed processing project&amp;lt;br&amp;gt;&lt;br /&gt;
* Introduced Slicer 3.6 for the MS Lesion Assessment step performed at Mayo Clinic. Images are being transferred from image repository at BWH and automatically opened and arranged within Slicer GUI for reading.  This was replacement of Client GUI using MIPAV that stopped working on new computers at Mayo Clinic.&lt;br /&gt;
The images are being loaded via generated MRML Scenes same way as in PET/CT and AGING STUDY projects &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* August 22 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Preprocessing pipeline merge with SUV computations &amp;lt;br&amp;gt;&lt;br /&gt;
- QA for SUVs computation was performed by Wendy Plesniak for images with known uptake values. &amp;lt;br&amp;gt;&lt;br /&gt;
- Discovered that image cropping step (not related to automated registration pipeline and SUVs computing) smoothes the images by doing interpolation when used with default settings. Got suggestions from Steve Piper using Nearest-Neighbor interpolation (&amp;quot;no interpolation&amp;quot;) for a time being&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
- This is the new project candidate. Requested for the images with failed manual segmentation and/or segmentation with FreeSurfer. The EM Segmentation run showed most acceptable results on one of the problem images back in February &amp;lt;br&amp;gt;&lt;br /&gt;
- The workflow will be developed and deployed similar to PET/CT ROI Longitudinal study approach - all preprocessing steps will be done with Slicer modules, all runs will be performed on local end-user machines.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
 &lt;br /&gt;
&lt;br /&gt;
* August 15 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- First 5 cases with 3-4 time points preprocessed for SUVs computation&lt;br /&gt;
&lt;br /&gt;
* August 8 2010&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Testing of installation and operation at users' site (Performed by Wendy Plesniak)&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* July 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Delivered beta version of registration pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
- Prepared installation and user manuals &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* June 11, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Registration modules completed &amp;lt;br&amp;gt;&lt;br /&gt;
- Irregular cases registration problem solved (when whole body and brain only scans are mixed for a timepoint)&amp;lt;br&amp;gt;&lt;br /&gt;
- Live demo of case setup and registration workflow for end users. Real case with 4 timepoints used&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Coming week plans&amp;lt;br&amp;gt;&lt;br /&gt;
- Adjust workflow based on end users' feedback&amp;lt;br&amp;gt;&lt;br /&gt;
- Integration with SUVs computing for PET scans&amp;lt;br&amp;gt;&lt;br /&gt;
- GUI for workflows dispatching and data organizing&amp;lt;br&amp;gt;&lt;br /&gt;
- (TBD) Integration with 4D time series analysis Slicer module&amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
* May 28, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- Migration to the latest Slicer 3.6 release candidate &amp;lt;br&amp;gt;&lt;br /&gt;
- Added webservice for new registration module: BRAINSFit &amp;lt;br&amp;gt;&lt;br /&gt;
- Test runs for new patients with 4 timepoints' scans &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Plans for next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI &amp;lt;br&amp;gt;&lt;br /&gt;
- processing workflow demo for end user &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 21, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Pilot version of portable web services and automated workflow tested: &amp;lt;br&amp;gt;&lt;br /&gt;
Linux: workflow and visual review passed&amp;lt;br&amp;gt;&lt;br /&gt;
Stress test for 25 timepoints passed &amp;lt;br&amp;gt;&lt;br /&gt;
MAC OS: workflow passed, visual review failing when PET/CT images are loaded into GUI simultaneously (bug report submitted)&amp;lt;br&amp;gt;&lt;br /&gt;
Windows: need to adapt command line modules and workflow management system to sygwin environment&amp;lt;br&amp;gt;&lt;br /&gt;
Plans for next week: integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI&lt;br /&gt;
&lt;br /&gt;
* May 7, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Selected registration and resampling modules with more precise and stable outputs. &amp;lt;br&amp;gt;&lt;br /&gt;
Started building portable web services and automated workflow &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 30, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- manual walk through the processing steps: ROI cropping, registration/resampling, PET pharmaceutical DICOM data retention. &amp;lt;br&amp;gt;&lt;br /&gt;
- testing workflow and web services packages distribution to end-users' machines&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* April 23, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : testing various registration and re-sampling algorithms (work in progress)&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation: as of collaborators' request, run existing EM Segmentation workflow for older low resolution pseudo-T1 images. The EM Segmentation works for those images with manual sampling. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 16, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
  Social Cognition Study: started Cortical Thickness Measurement module build (bases on NA-MIC ARCTIC pipeline) &amp;lt;br&amp;gt;&lt;br /&gt;
  PET/CT ROI/Longitudinal Study Registration : Design specs, PET-to-CT images registration tests on training data. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 9, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. GUI update based on end-user experience.&amp;lt;br&amp;gt;&lt;br /&gt;
User request: automated label maps' volumes calculation (Currently possible from Slicer3 GUI)&amp;lt;br&amp;gt; &lt;br /&gt;
PET/CT ROI Project. Initial design specs discussion with end-users and co-developers&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure&lt;br /&gt;
Verification of segmentation workflow GUI: from registering new case to reviewing results&amp;lt;br&amp;gt;&lt;br /&gt;
Cross study test of segmentation workflow: MGH/MS Center data - success,  HIV Project data - some EM Segmentation scene tuning is needed &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*&lt;br /&gt;
* April 2, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. Segmentation workflow completed&amp;lt;br&amp;gt;&lt;br /&gt;
* Coming Week plans:&amp;lt;br&amp;gt;&lt;br /&gt;
- Document Segmentation Workflow. Follow up with end users &amp;lt;br&amp;gt;&lt;br /&gt;
- Start with Cortical Thickness and ROI-in-longitudinal studies workflows&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* March 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All essential processing and workflow interaction clients are ready.&amp;lt;br&amp;gt;&lt;br /&gt;
- Completed segmentation for 10 out of 50 patients. The remaining cases will be finalized upon manual lesion segmentation and QC verification of WM/GM/CSF and Deep GM segmentation's. &amp;lt;br&amp;gt;&lt;br /&gt;
- TODO next week: refine QC GUI and data tracking / progress monitoring schema. &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&amp;lt;br&amp;gt;&lt;br /&gt;
- New Slicer3 web services added: re-slicing with reference image volume, casting image scalar type &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
* March 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Segmentation maps Merging Services for GM/WM/CSF (Slicer EM Segemnter), Lesion (Slicer, Manual), and Deep GM (FreeSurfer)  &amp;lt;br&amp;gt;&lt;br /&gt;
- Deep GM segmentation pipeline adopted as optional service for Social Cognition Study (22 out of 50 cases processed) &amp;lt;br&amp;gt;&lt;br /&gt;
- (In progress) GUI client for Launching Segmentation results merging with optional Deep GM segmentation with FreeSurfer &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- Complete GUI Client for Segmentation result merging &amp;lt;br&amp;gt;&lt;br /&gt;
- Progress Monitoring services for entire Study processing: EM Segmenter Preprocessing, EM Segmentation, Lesion Segmentation (including human activities assignments), Deep GM segmentation, and results consolidation. &amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* March 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All 50 cases went through &amp;quot;basic&amp;quot; One-channel EM segmentation (GM/WM/CSF) &amp;lt;br&amp;gt;&lt;br /&gt;
- Basic pipeline start-up command line client created: user has two options - request brainmask extraction or provide with previously extracted brainmask for a given subject &amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison of GM/WN/CSF performed for Slicer EM Segmenter and FreeSurfer recon-all (used with default settings). &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmenter provides more accurate output &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmentation pipeline runs faster (40 minutes vs 12 hrs when no brainmask extraction requested) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO:&amp;lt;br&amp;gt;&lt;br /&gt;
- merging modules for automatic 1-channel EM segmentation and manual lesion segmentation &amp;lt;br&amp;gt;&lt;br /&gt;
- Emerge Cortical Thickness pipeline project: use NAC ARCTIC processing steps and modules &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Selected stable EM Segmentation scenario: White Matter, Gray Matter, and Cerebrospinal Fluid &amp;lt;br&amp;gt;&lt;br /&gt;
- First 16 cases are segmented for selected scenario. Nine more cases are preprocessed for EM Segmentation.&amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison to segmentation with FreeSurfer showed better accuracy for Slicer2 EMSegmenter &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure &amp;lt;br&amp;gt;&lt;br /&gt;
- Three prerpcocessed cases failed during volume ICC masking with in-house build utility. Evaluated switching to Slicer3 Mask and island removing modules.&amp;lt;br&amp;gt;&lt;br /&gt;
- Initial design specs discussion for cortical thickness measurement pipeline. ARCTIC pipeline selected. ARCTIC preprocessing steps signifficantly overlap with EM Segmentation preprocessing workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
  &lt;br /&gt;
* February 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: &amp;lt;br&amp;gt;&lt;br /&gt;
A) parameters tuning for EM Segmenter itself (work with EM Segmenter developer), template scenes creation &amp;lt;br&amp;gt;&lt;br /&gt;
B) update preprocessing pipeline - deep gray matter atlases included &amp;lt;br&amp;gt;&lt;br /&gt;
C) test and debug preprocesing pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
D) identified missing modules: atlas autocalibration for EM Segmentation scene, Island removal for ICC mask&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- Review currently deployed modules. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: reviewed firts seven subjects' outputs, added volume orientation module into pipeline (prevents ICBM atlas linear registration failures)&amp;lt;br&amp;gt;&lt;br /&gt;
- Fused ICC(brainmask) extraction module with EM Segmenter preprocessing. Three scenarious implemented: start with pre-extracted ICC mask (longitudinal studies case), run with ICC ectration, run with ICC extraction AND ICC correction before ICBM atlas preporcessing. &amp;lt;br&amp;gt;&lt;br /&gt;
- Completion of Human activities GUI (QC, ICC Correction) planned for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: Volume Orientation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: automated preprocessing pipeline for Slicer2 EM Segmenter test version deployed. Seven cases pre-processed.&lt;br /&gt;
- PET Quantitative measurements: Preliminary design specs discussion.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: BSplineRegistration (for non-linear registration), ResampleVolume2 (for atlases resampling based on image atlase templates registration). Local and Network runs are implemented, Cluster/GridWizard implementation pending.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Slicer EM Segmenter module: preprocessing design for Slicer2 EM Segmenter&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Adapting for Slicer2 EM Segmenter (mostly from pipelines and services for previous projects)&lt;br /&gt;
  -- Integration with FreeSurfer modules for bisafield correction, brainmask extraction, and linear registration of ICBM atlases&lt;br /&gt;
  -- Preprocessing updates for non-linear registration of ICBM atlases with Slicer2 (image re-orientation service designed)&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 29, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- EM Segmentaton pipeline: preprocessing results are being transferred to XNat (anonymized data, Central XNat) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Slicer EM Segmenter module: discussed agenda and scheduled a work meeting for Social Cognition Study image segmentation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Testing stage, 95% completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- SPL XNat server: verified data exchange via RESTfull web services.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 22, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Follow up with White Matter Lesion Segmenter and Scull Stripping Modules developers: Work in Progress&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Work in Progress, 60%+ completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Discussed SPINE image repository migration to XNat&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 15, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. &lt;br /&gt;
- Social Cognition Study: &lt;br /&gt;
Work-in-progress on intermediate (reconstruction) and results (resources) data storage at XNat.&lt;br /&gt;
&amp;lt;br&amp;gt;Reviewing and preparation more cases for EM Segmentor (Slicer 3.5) tuning.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* NA-MIC Project Week&lt;br /&gt;
Selecting candidate Slicer modules for other than Lesion EM Segmentation topics of Social Cognition study: Withe Matter Lesion Segmenter (UNC), Scull Stripping utility from UIOWA.&lt;br /&gt;
Reviewing issues of currently used Scull Stripping Slicer Extension and Slicer 3.5 EM Segmenter.&lt;br /&gt;
&amp;lt;br&amp;gt;XNat Data organizing training&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 1, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Preparation of Demo for NA-MIC work week: &lt;br /&gt;
- COPD Study. Added Remote pipepline start interface (represents real world scenario where Xnat repository, Processing modules and User are at different sites)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
- EM Segmentation. Added human activities steps to the workflow: ICC (brainmask) correction and EM Segmantation scena load per se.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 25, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Pilot workflow pipeline for EM Segmentation (all steps except user-activity step: ICC correction assignment and tracking)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 18, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Build and tested web services for EM Segmentation image preprocessing: DICOM-to-NRRD conversion, registration, skull stripping, image masking.&lt;br /&gt;
Started building workflow pipeline (subject to finish first version next week)&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Started Collecting Library of Slicer Build number vs. functional modules and extensions.&lt;br /&gt;
Plan for NAMIC project week: scheduled meetings for XNat data customization, Skull-stripping modules tuning, identified Social Cognition study cases that fail EM Segmentation processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 11, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Updating and verification of EM Segmentation Scenario&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Projects:ARRA:SlicerWF:UseCaseScenarios#Usecase_MS_lesion_Assessment&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Familiarizing with Slicer3.4/5 Modules required for implementation of EM Segmentation Scenario. Participation in debugging and/or usage tuning of Dicom Conversion, Registration, Skull Stripping, Masking, and Image Casting modules. &lt;br /&gt;
&lt;br /&gt;
* December 4, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Slicer3.4's EM Segmentation and Visual QC as part of image processing pipeline for Social Cognition Study for MS Patients.&lt;br /&gt;
Project emerged. EM Segmentation template creation debugged.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
Emphysema Measurements (COPD Study) - workflow stability and scalability test.&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 27, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Emphysema Measurements (COPD Study).&lt;br /&gt;
Added compensation for long running calculations and time-outs to the main computing pipeline.&lt;br /&gt;
Visual QC (work in progress)&lt;br /&gt;
** Infrastructure&lt;br /&gt;
XNat data structure customization, metadata storage, results consolidation: new feature request list creation (work in progress)&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 13, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
*** Pilot system for whole processing cycle for Emphysema Measurements (COPD Study) including the following:&lt;br /&gt;
Web query for CT session file list download&lt;br /&gt;
Pilot user interface for submitting the file list and starting processing pipeline&lt;br /&gt;
Notification about processing steps and failures&lt;br /&gt;
Upload results to XNat repository (at this stage results are uploaded into same folder where original scans are(*))&lt;br /&gt;
*** Immediate Plans&lt;br /&gt;
Complete Visual QC module&lt;br /&gt;
Design and implement meta-data transfer to XNat (including processing details and MRML files for loading images into the 3D Slicer)&lt;br /&gt;
&lt;br /&gt;
(*)Customization of results storage&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 6, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Tuned and debugged multiple subjects processing for: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat.&lt;br /&gt;
***Started working on quality control embedding into the above scenario. Plan to complete and video-record demo next week.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***Published general Product Integration scenario flow chart to collaborators' community. Discussion is open and in progress&lt;br /&gt;
&lt;br /&gt;
* October 30, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Piloted and tested the sequence: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat(1).&lt;br /&gt;
***Performance test of overall cycle: data transfer from remote serve is a bottleneck as expected&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data browsing features reviewed.&lt;br /&gt;
(1) Not automated yet&lt;br /&gt;
* October 23, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Defined COPD processing scenario with interoperability between Xnat, 3D Slicer Command Modules, Workflow, and Gridwizard Enterprise.&lt;br /&gt;
***Pilot version of Emphysema Measurements workflow pipeline deployed.&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data transfer features reviewed. Use account at XNat Central during learning curve.&lt;br /&gt;
***Feasibility test of 3D Slicer fiducials module for ROI highlights during QC and manual image processing activities. &lt;br /&gt;
* October 16, 2009&lt;br /&gt;
**Lung CT Scans Processing. Pilot project emerged. GenerateEmphysemaMeasurements module deployed as a webservice that submits jobs to computational cluster.&lt;br /&gt;
**EM Segmentation. Familiarized with GUI steps. Started working on automation steps outlining&lt;br /&gt;
**3D Slicer and XNat interaction. Got an overview from Wendy Plesniak.&lt;br /&gt;
* October 1 - 7, 2009&lt;br /&gt;
**Selected two first priority Projects: EM Segmentation of brain MRI images; Lung CT Scans Processing (COPD Study)&lt;br /&gt;
**Got initial outline of user requirements and design specs&lt;/div&gt;</summary>
		<author><name>Azaitsev</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=66950</id>
		<title>Projects:ARRA:SlicerWF</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=66950"/>
		<updated>2011-05-01T17:48:57Z</updated>

		<summary type="html">&lt;p&gt;Azaitsev: /* Presentations */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Projects:ARRASuplements|Back to Slicer ARRA home page]]&lt;br /&gt;
= Aim =&lt;br /&gt;
Supplement 3D Slicer and Extensible Neuroimaging Archive Toolkit (XNAT) with workflow management system. Provide integration and interoperability between 3D Slicer, XNAT Services and 3-rd party image processing applications and high performance computing systems. Implement it as within currently developed Structural Planning and Implementation in Neurological Exploration (SPINE) System.&lt;br /&gt;
&lt;br /&gt;
= SPINE Project Documentation =&lt;br /&gt;
[http://cni.bwh.harvard.edu/projects/spine/index.html SPINE Docs]&lt;br /&gt;
&lt;br /&gt;
= Presentations =&lt;br /&gt;
* Segmentation Workflow. PECS University Social Cognition Study.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:SlicerWF_NAC_PECS_Workflow.pdf]]&lt;br /&gt;
* EAB10_ARRA Annual Progress Report Slides.&amp;lt;br&amp;gt;&lt;br /&gt;
[[media:EAB10_ARRA_WF_2011_Zaitsev.ppt | Service Oriented Solutions for 3D Slicer. EAB10_ARRA_WF_2011. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:EAB10_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:NAMIC_ARRA_WF_2011_Zaitsev.ppt  | NAMIC Annual Report 04/2010-03/2011. NAMIC_ARRA_WF_2011_Zaitsev. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:NAMIC_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:Slicer_WF_Slicer4CARMAWorkflow.ppt  | CARMA Workflow. Cardiac Ablation Followup. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:Slicer_WF_Slicer4CARMAWorkflow.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* CARMA Project Beta release Demo Location: http://cni29.bwh.harvard.edu/SlicerWFDemo/index.php&lt;br /&gt;
&lt;br /&gt;
* Segmentation Workflows: Screenshots, scans' and study description : [[File:SlicerWF_EMSegmentProjectsReview.zip]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
= All Hands Meeting Pages =&lt;br /&gt;
* Salt Lake City 2011 Winter [http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA SLC_2011_WorkFlow]&lt;br /&gt;
* MIT 2010 Summer [http://wiki.na-mic.org/Wiki/index.php/Summer_project_week_2010_Workflows_SOA MIT_2010_WorkFlow]&lt;br /&gt;
&lt;br /&gt;
= Research Plan =&lt;br /&gt;
*Create a stand-alone SPINE desktop agent with fully functional data exchange and communication mechanisms towards 3D Slicer and XNAT.&lt;br /&gt;
*Develop Service Oriented Architecture (SOA) SPINE System that will include 3D Slicer image processing modules deployed as web services as well as a workflow management system to orchestrate interaction between 3D Slicer, XNAT, and 3-rd party tools.&lt;br /&gt;
*Implement two-way control and communications between 3D Slicer and SPINE modules.&lt;br /&gt;
*Adapt SPINE System for cluster and grid computing scenarios.&lt;br /&gt;
*Provide with workflow and 3D Slicer web service wrappers editing tools.&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:UseCaseScenarios| Use Case scenarios]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PETCTWorkflow| PETCTWorkflow]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:AgingStudySegmentation| AgingStudySegmentation]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:TwoTensorTractography| TwoTensorTractography]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:LongitudinalMultimodalityRegistrationSuite| LongitudinalMultimodalityRegistrationSuite]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:MigrationJavaClients2QT| MigrationJavaClients2QT]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PediatricMSSegmentation| PediatricMSSegmentation]]&lt;br /&gt;
*[[DBP3:Utah:RegSegPipeline| MRI-based study and treatment of atrial fibrillation]]&lt;br /&gt;
&lt;br /&gt;
= Application Server / Workflow Engine Downloads =&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:WFEngineDownloads| Download Links]]&lt;br /&gt;
&lt;br /&gt;
=Key Personnel=&lt;br /&gt;
* Charles Gutmann, MD., 4%,  9-17-2009 through 9-16-2011&lt;br /&gt;
* Alexander Zaitsev, Ph.D., 75%, 9-17-2009 through 9-16-2011 &lt;br /&gt;
&lt;br /&gt;
=Annual Progress Statements =&lt;br /&gt;
'''2010-11''' &amp;lt;br&amp;gt;&lt;br /&gt;
The  April 2011 – March 2011 period was devoted on developing portable workflow solutions that can be deployed on end-users' workstations or notebooks with minimal or no system administration activities. This is in contrast to the server-side deployment. The following scenarios had been deployed and used for actual projects that require the following types of workflows: PET/CT registration and computation of biomarker driven brain physiological activities, Brain MRI Images segmentation,  MRI and MRI Angiography images pre-processing for cardiac ablation outcome estimation. Some  workflows (like EM Segmentation) had been utilizing various scenarios, some research projects  (like evaluation of chemotherapy outcome) require two types of workflows to assess physiological and structural changes. Starting from the 4th Quarter of 2011, the migration project had been emerged in order to embed Workflow GUIs into newly developed Slicer4 Suite. The existing rich client Java GUI applications are being re-written as C++/QT Sliceletts units, new modules (such as cardiac ablation project support) are had been written from scratch. The latter are being deployed from the Slicer4 GUI and act at a liaison between Slicer4 and Application Server containing  workflow and Slicer modules deployed as services. The feedback from the end users indicates that Workflow approach for the complex processing improves productivity, aids to the processing standardization and contributes to the overall experience using 3D Slicer&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
=Quarterly Progress=&lt;br /&gt;
&lt;br /&gt;
* NAMIC Annual Progress Slides (April 2010 - March 2011):&lt;br /&gt;
&lt;br /&gt;
* '''1st Qtr, 2011''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study: Second release is under testing by end-users. &lt;br /&gt;
*** Added MRI registration to aid ROI drawing on PET scans&lt;br /&gt;
*** Improved SUV results reporting and added flexibility to update ROI lookup table&lt;br /&gt;
*** Automated EM Segmentation of MRI images for computing SUVs for white matter, CSF, and whole brain (80% completion)&lt;br /&gt;
*** Integration with SPECTRE scull stripping module (70% completion) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** EM Segmentation: Automated WF Pipelines are created &amp;lt;br&amp;gt;&lt;br /&gt;
*** Flexible atlas selection (Pediatric, etc) feature added&lt;br /&gt;
*** Workflows implemented for EM Segmenter 3.6.2 and 3.6.3 (1st Qtr 2011 release)&lt;br /&gt;
&lt;br /&gt;
** Cardiac ablation results follow-up: Workflow for registration and ROI selection of cardiac MRI and MR Angiography &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Wrokflow and Web Services for prospective DTI tractography modules (currently written as Matlab modules at PNL) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Web Services for SPECTRE Scull stripping module&lt;br /&gt;
*** Accuracy and performance tuning&lt;br /&gt;
*** 50% completion&lt;br /&gt;
&lt;br /&gt;
** Migration Front End GUI to Slicer4/QT:&lt;br /&gt;
*** EM Segmentation&lt;br /&gt;
*** Cardiac Ablation Study&lt;br /&gt;
&lt;br /&gt;
** DICOM Uploader and Desktop Browser for XNat Image repository (alpha version - tested for MGH MS Center studies, proposed to use with MI2B2 Clients and Services)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''4th Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study and EM Segmentation for Aging Study are deployed at end-user sites and actively used for research. &lt;br /&gt;
** Adopted EM Segmentation preprocessing pipeline for HIV Study: high resolution SPGR images, integration with FreeSurfer brainmask extraction outputs; integration of Slicer SPECTRE module for brainmask extraction is in progress.&lt;br /&gt;
** The following post-release upgrades had been implemented based on end-user feedback: Application Server basic controls are performed from Rich Client GUI as alternative to traditional IT administration activities. The controls are implemented on point-and-click bases and include web services and workflow application deployment and upgrades, application server start and stop as well as warning end user when the server is not accepting request.&lt;br /&gt;
** Added DICOM downloads and results uploads of PET/CT pipelines from and to XNat Repository&lt;br /&gt;
** Created Services and Workflow for Matlab Prototypes modules. Case Study: tractography for DTI images&lt;br /&gt;
** Extended XNAT integration services:&lt;br /&gt;
*** Browsing capabilities of XNat data repository from the Workflow Applications&lt;br /&gt;
*** Improved DICOM upload and download performance&lt;br /&gt;
*** Added Metadata organizing services for uploaded DICOM images: header data extraction, image snapshots creation. &lt;br /&gt;
** Started project for Rich Client GUI migration from Java desktop application to build into SLicer4 QT modules. This affects mostly front-end GUI and has the following approaches: distribution with the Slicer4, end-user will select desired workflow application from Slicer4 menu while QT-written modules provide with the same functionality as Java Rich Clients. Case Study for the Migration process: registration suite for longitudinal studies that include multi-modality images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* '''3d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Concentrated on building downloadable workflow applications that could run both in desktop (new) and server environment, and that require minimum IT administrative resources. The desktop deployment is in compliance with Slicer3 general deployment concept.&lt;br /&gt;
*** The following use case scenario had been chosen: PET/CT image processing for longitudinal studies, EM Segmentation for longitudinal Aging Study.&lt;br /&gt;
** Released workflow application for PET/CT image processing for longitudinal studies. Provided end users with training and documentation.&lt;br /&gt;
*** The PET/CT processing workflow was designed to be a general application used whenever both structural patterns and metabolic activities are within the research scope. &lt;br /&gt;
*** The desktop version is tuned to use minimal computer resources, so the automates processing instances do not interfere with human activities. Automated activities may include, for example, registration and PET scan's standard uptake values computing, and manual human activities may include image cropping, quality control, and labeling voxels of interest.&lt;br /&gt;
** Core services and EM Segmentation preprocessing workflow was build for retrospective Aging Study. Tuned the Slicer3 webservices for processing low grade images acquired in mid 90s. Entire workflow is implemented with Slicer3 only modules and can be deployed locally and on the servers. Usage of Service Oriented Architecture (SOA) as a core technological approach allowed reusing most of the web services that had been build for PET/CT project. &lt;br /&gt;
** Continued embedding Slicer3 application and modules into previously released processing pipelines: replaced MIPAV with Slicer3 GUI for lesion assessment step in the multi-center Pediatric MS Cohort image processing &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''2d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Completed Social Cognition Workflow Implementation. This includes EM Segmetnation pre- and post-processing pipelines, data tracking, and integration with 3d party image processing utilities, as well as processing results acquired manually with Slicer GUI.  &lt;br /&gt;
** Multi-modality image registration and ROI selection/alignment workflow for longitudinal studies. &lt;br /&gt;
*** Use case: PET/CT image processing for longitudinal studies. &lt;br /&gt;
*** Build portable library of Slicer modules as web services and workflow that are deployed and run on a end-users' worksatations without utilization of SPL and other servers. The web services include novel Slicer3 modules, such as BRAINSFit and BRAINSResamle &lt;br /&gt;
*** Started working with Slicer3 developers on Slicer 3.8 GUI wizard to communicate with workflow instances.&lt;br /&gt;
** Participated at NA-MIC Summer 2010 Project Week: [[Summer_project_week_2010_Workflows_SOA]]&lt;br /&gt;
&lt;br /&gt;
=Progress=&lt;br /&gt;
* April 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Open Discussion for Packaging WF QT Modules as Slicer4 extensions (waiting for SOPs)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review supported projects http://wiki.na-mic.org/Wiki/index.php/File:SlicerWF_EMSegmentProjectsReview.zip &lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (required by Study)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Slicer Modules General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Standardizing Crop Volumes Output (with A. Fedorov's module)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 22, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Beta release ready. Demo Location: http://cni29.bwh.harvard.edu/SlicerWFDemo/index.php&lt;br /&gt;
* TODO: Tutorial. Original inputs copy/renaming&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 15, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Adding App server auto-config features&lt;br /&gt;
* Finalizing the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 08, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Second release beta build tested on cosutmer side &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review registration quality (with Dr. Meier). Angiography images' Resampling tuned. &lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 01, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the second release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
XNat Integration&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* (Java) GUI for Project Browsing and DICOM Series Upload. Post-upload DICOM processing tested and debugged&amp;lt;br&amp;gt;&lt;br /&gt;
* Ready for integration with mi2b2 client.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Migrated to Latest Slicer 3.6.3 stable release: only the Input scene had to be updated, the API remained the same&lt;br /&gt;
* Tested EM Segmenter with CMTK4Slicer extension - processing takes to much time on Linux_64bit machine, rolled back to BRAINSFit registration. When used on Mac OS X build, the Slicer could not start (bug report 1126).&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SPECTRE Scull Stripping:&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Testes for various use cases: the module is extremely sensitive to T1 MRI quality (does not work for most MRIs from PET/CT project&lt;br /&gt;
* TODO next week: check for FLAIR images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Slicer4 QT GUI and Cropping activity in progress.&amp;lt;br&amp;gt;&lt;br /&gt;
* Tried direct MRA to MRA registration option: resampling with LMRI registration transforms works better.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Extra VOI labels revised&lt;br /&gt;
* Debugging of SUV results' renormalization step&lt;br /&gt;
* TODO: ICC extraction / whole brain total uptake computing; EM Segmentation for R_WM, L_WM SUV computing and BPH estimation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SCULL STRIPPING/SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Installed and tested CLI option on Linux_64bit platform&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Workflow interruption before BSPline registraton: BPEL Module completed. Slicer4 QT GUI and Cropping activity in prorgess.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Implemented and Tested with end-users proposed changes: denormalization of SUV results, adding more VOI labels, added FLAIR MRI in addition to T1s for VOI drawing&lt;br /&gt;
* Tested manual ICC extraction using PET scans: works satisfactory with island removal and cropping followed by threshold level labeling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4&lt;br /&gt;
* Change proposed: interrupt workflow after affine registration and have user crop the VOI. This is to prevent excessive deformations for BSpline registration and resampling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4. User has option to choose the atlas that fits better for the given subject (NOTE: hardcoding must be rewritten for atlas linking)&lt;br /&gt;
* PETCT test - the problem is that T1s are low resolution and with contrast. Proposed using T1s without contrast&lt;br /&gt;
* PETCT change request: users wants to compute SUV for entire ICC. Had demo how to segment brainmask/ICC using PET scan. The derived brainmask label can be used for SUV computation.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - cmpleted&lt;br /&gt;
* Sample cases run - excessive deformation after BSpline registration hase&lt;br /&gt;
* Next week plan - pull tuning controls to front-end of pipeline API, start working of QT module for CARMA registration&lt;br /&gt;
* May consider other than BRAINSFit registration modules&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Design plan for change request: more VOI labels, add FLAIR in addition to T1 for VOI drawing, T1s segmentation&lt;br /&gt;
* Tested segmentation for sample cases - artifacts from poor quality MRIs lead to exclusion of parts of ICC from segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Completed troubleshooting of EMSegmenter module calling from Java (need TCL libs to be pulled from Slicer environment)&lt;br /&gt;
* Tested EMSegmenter autoruns for HIV and Pediatric MS patiens. Work as expected, subject to improvement of PED MS case segmentation by building better skull/neck/air atalses&lt;br /&gt;
* Suggested usage of two subsets of atalases: with and without neck. The Subject MRIs have to be cropped accordingly or best fit atlas has to be selected&lt;br /&gt;
* Made no-neck cropped atlas collection for default EMSegmenter scenario&lt;br /&gt;
* Tested with PET/CT study MRI cases - see above &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - in progress&lt;br /&gt;
* Next week goal - have back end processing ready&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Longitudinal Study&lt;br /&gt;
* Added MRI registration to the pipeline&lt;br /&gt;
* Troubleshooting of complex XML schema issues on Linux machines (some modules working on MAC do not work on Linux). As a workaround - did not include MRI convert and register part into base BPEL module. Used separate services (transparent for end-user)&lt;br /&gt;
* TODO next week for change request completion: explicit pixel type casting for MRI in BRAINSFit, VOI MRML scene update (currently MRI added on top of schema)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* February 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipeline for Pediatric MRI. Same scenario as for HIV Project, icbm pediatric atlases (Completed, verified)&lt;br /&gt;
* Collected NIH healthy brain development atlases: various age ranges from 4.5 to 18 yo. Converted to Slicer readable format &lt;br /&gt;
* Work on web services for the new automated EM Segmenter module (release Nov 10 - current). Verified task completion both for adult and pediatric images. Discussed tuning parameters for work load balance on workstations.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Started working on MRI registration to the reference CT scans. &lt;br /&gt;
* Design specs for optional White Matter segmentation for SUV computing.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* February 4, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipelines for Pediatric MRI (in progress)&lt;br /&gt;
* Adapting Pediatric T1 atlases for &amp;quot;Human Brain&amp;quot; build-in EM Segmentation wizard (in progress)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 28, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Verifying EM Segmenter module for latest builds and HIV/PED MS Studies (report pending)&lt;br /&gt;
* Work with SPECTRE module developers with pediatric MRI brainmask extraction&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* January 21, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Compiling plan for WF FrontEnd GUI migration to Slicer4/QT Widgets&lt;br /&gt;
* Preparing for annual progress report&lt;br /&gt;
&lt;br /&gt;
* January 14, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI: Integrated into the Slicer4 as Slicelet (or thin Client)&lt;br /&gt;
* Participation at AHM-2011, discussing integration of SPECTRE module and updated approach to EM-Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA&lt;br /&gt;
&lt;br /&gt;
* January 7, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* HIV project workflow delivered. Major additions relate to user convenience: &lt;br /&gt;
- Project-specific parameter settings, importing T1s and brainmasks from FreeSurfer outputs with conversion to NIFTI, resampling brainmask to original scans and automatied subject addition.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Follow up with end user: need to add MRI scans, if available, addition and registration to CT in order to ease VOI drawings.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
 &lt;br /&gt;
* December 31, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Follow-up with user Experience for AGING Study Segmentation (Positive feedback)&lt;br /&gt;
* Target date for HIV project delivery - next week&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Self-training for QT widget development&amp;lt;br&amp;gt;&lt;br /&gt;
* Outlined Workflow Rich Clients migration strategy from Java to QT/Slicer4:&amp;lt;br&amp;gt;&lt;br /&gt;
** Use Java Stubs (similar to SPECTRE integration) or file binding for envocation of workflow pipelines. (See SOAP remark below)&lt;br /&gt;
** Direct Web Servisec calls must be wrapped into REST protocol. The reason: NON-commerchial QT kit does not include SOAP protocol for web servises.&lt;br /&gt;
** The GUI will be implemented as page widget or QT dialog GUI forms called from within Slicer4.&lt;br /&gt;
** Communications between Slicer4 and WF GUI will be set via child-parent and signal-slot relations&lt;br /&gt;
* Worked on a Prototype for Basic EM Segmentation QT widget (70% complete). Will work on integrtion with SLicer4 during the AHM-2010&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
XNAT Integration&lt;br /&gt;
* Debugged XNAT RESTFul API usage for uplaoding DICOM series followed by header data extraction and image snapshots creation&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Added compensation for failed atlas registration (subject for old poor quality pseudo-T1 images): blank probability maps are created in case of failure.&lt;br /&gt;
* Data preparation module for FreeSurfer data import near completion. Expected time for deployment at end-users workstations - first week of January&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Discussed strategy for EM Segmentation pipeline solutions collection (K. Pohl, R. Kikinis)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* RE-using the same core workflow as for 1-channel EM Segmentation of AGING STUDY cases&lt;br /&gt;
* Added data input preparation module: ICC label mask preparation and skull-stripping based on FreeSurfer brainmask output volume.&lt;br /&gt;
* Two-channel EM segmentation pipeline (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE / GENERAL Development &amp;lt;br&amp;gt;&lt;br /&gt;
* Worked on plans for migrating fro rich workflow Java clients to embedded workflow windows inside the Slicer.&amp;lt;br&amp;gt;&lt;br /&gt;
The embedded workflow management clients are to be implemented with QT/PyQT toolkits&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
INTEGRATION WITH XNAT:&amp;lt;br&amp;gt;&lt;br /&gt;
* Automated DICOM series upload with triggering DICOM headers parsing at XNat site (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress. &lt;br /&gt;
- Results upload to XNat (Completed) &amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat based on user's input (Project + Subject + PET or CT session / scan) (Completed)&amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat - perfomance boosting solution for downloads found , web services services are created, relinking for the client side in progress &amp;lt;br&amp;gt;&lt;br /&gt;
- Xnat querying for subjects and automated subject addition into the workflow (In Progress) &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-segmentation module added for auto correction of segmentation results. Particularly - relabeling CSF voxels segmented as Air inside the intracranial cavity. This was requested by end-users after processing images with zero-signals in CSF voxels &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting automated dual-echo DICOM images conversion and split into two NRRD volumes&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT / EM Segmentation pipeline:&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting memory allocation issues for scull-stripping module SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
COPD Project:&amp;lt;br&amp;gt;&lt;br /&gt;
* Benchmark test for accelerated DICOM downloads from XNat (remoote XNat Central server): we can handle at least 6 cases (4 CT scans in each) per hour, which is compatible with current workload quotes on SPL cluster processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* December 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Deployed Version 1. &amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Test project chosen as a closest match to registration scenario: Pediatric MS Cases from MGH - requires periodic image preview for different &lt;br /&gt;
modalities taken from vaious time points. Label maps for VOIs resampling is also required.&lt;br /&gt;
&lt;br /&gt;
* November 26, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user. Version 1 is complete&amp;lt;br&amp;gt;&lt;br /&gt;
* Started working on integration with XNat&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on input data organizing modules&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 19, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user (70% done)&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Universal Registration Workflow for Longitudinal Studies - design specs in progress&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 12, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Minor tuning to EM Segmentation template as of users' feedback&lt;br /&gt;
* Users started using the workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed input data conversion from Genesis to Slicer native or NIFTI format. Our help may be needed in input data organizing.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Tuned application according to co-laborators (PNL) needs&amp;lt;br&amp;gt;&lt;br /&gt;
* The webservices and BPEL workflow application are tested ready to accept computation requests from PNL case tracking system &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Discussed Universal Registration Workflow for Longitudinal Studies&lt;br /&gt;
* Started the thread about possible cooperation with Children hospital's image processing pipelines and integration with Xnat &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 5, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Webservices and workflow pilot project created and deployed on Psychiatry Neuroimaging Laboratory subnet &amp;lt;br&amp;gt;&lt;br /&gt;
* The V.1.0 deployment is scheduled for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 29, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Most of functionality is completed. Some volume statistics post processing is pending&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL EM SEGMENTATION Pipeline: &amp;lt;br&amp;gt;&lt;br /&gt;
* The SPECTRE scull stripping module. Started integration into EMS workflow. Made some test runs from Slicer GUI&amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Identified as a candidate for Workflow Application&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 22, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* All back-end functionality are implemented&amp;lt;br&amp;gt;&lt;br /&gt;
* EM Segmentation scene usability is confirmed by end-user&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for next week: add Label Statistics computation for CSF/Brain/ICC &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 15, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* The latest (October) builds of Slicer 3.6.2 produced acceptable results. This was verified by the target users. The EM Segmentation will be performed on Slicer 3.6.2 or later&amp;lt;br&amp;gt;&lt;br /&gt;
* The new Web services had been created and added to the pipeline as optional processing steps: Biasfield correction (implement novel N2ITKBiasFieldCorrection module) and Volume's scalar datatype casting (as workaround for Biasfield correction module not preserving image scalar datatype - the bug is filed) &amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed the Front-End GUI design with target users. The design pattern is taken from the PETCT project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 8, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-deployment support. Tuned CT registration as of user's feedback.&lt;br /&gt;
* Adapting to the Single Slicer build: Slicer 3.6.2. Found label duplicates in the label lookup table - will ask user if it's tolerable. Waiting for the Slicer 3.6.2 build that contains all required modules. Rolling back label tag appending code for SUVs - the latest Slicer build appends the tags.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Resumed development. The priorities are set for usage of Slicer 3.6.2 - subject for EM Segmentation scene tuning. Continued coding for Scene creation for Slicer 2.8 - as a backup option for ongoing research project.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 1, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized V1.0 release based on end-user feedback: updates relate mostly to error proofing and SUV values representation&lt;br /&gt;
* Post-deployment support. Users pre-processed first set of patients &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* September 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* System deployed and tested at End Users' site.&amp;lt;br&amp;gt;Users are trained to perform all tasks required by the workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
* Got positive feedback with suggestions on Slicer Scenes' layouts improvement and PET scans' SUV (standard uptake values) results display&lt;br /&gt;
* Two distribution packages are assembled: Lunix and MAC OS versions. The difference in two packages is in specific Slicer3.6/3.7 builds - subject to Slicer Linux builds debugging.&amp;lt;br&amp;gt; As a workaround for Linux deployment - multiple Slicer builds are used to perform various tasks (registration, opening editing scenes in Slicer, SUV computing)&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for coming week - finalize V1.0 release based on end-user feedback&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Embedded SUV computations into the workflow (as system calls - will be translated into web service later)&amp;lt;br&amp;gt;&lt;br /&gt;
* Pre-release demo for end users.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Create and debug EM Segmenter scenes template for Slicer 3.6 and 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* September 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation - workflow pipeline and deployment verified&amp;lt;br&amp;gt;&lt;br /&gt;
* Tested EM Segmentation scenes within Slicer 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
* Started migration of EM Segmentation to Slicer 3.6. Discovered issues had been reported to EM Segmenter module designers &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* August 29 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation completed. Preprocessing Pipleine completed 80% (subject for input registration parameters tuning) &amp;lt;br&amp;gt;&lt;br /&gt;
* Most webservices (for registration and resampling steps) had been taken and re-used from PET/CT ROI/Longitudinal Study - showing the advantage of service-oriented software design and deployment.&lt;br /&gt;
* Continued on distribution and deployment of the service/workflow applications: on PET/CT and AGING STUDY projects.&lt;br /&gt;
&lt;br /&gt;
PEDIATRIC Multiple Sclerosis Cohort. Support of multi-center distributed processing project&amp;lt;br&amp;gt;&lt;br /&gt;
* Introduced Slicer 3.6 for the MS Lesion Assessment step performed at Mayo Clinic. Images are being transferred from image repository at BWH and automatically opened and arranged within Slicer GUI for reading.  This was replacement of Client GUI using MIPAV that stopped working on new computers at Mayo Clinic.&lt;br /&gt;
The images are being loaded via generated MRML Scenes same way as in PET/CT and AGING STUDY projects &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* August 22 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Preprocessing pipeline merge with SUV computations &amp;lt;br&amp;gt;&lt;br /&gt;
- QA for SUVs computation was performed by Wendy Plesniak for images with known uptake values. &amp;lt;br&amp;gt;&lt;br /&gt;
- Discovered that image cropping step (not related to automated registration pipeline and SUVs computing) smoothes the images by doing interpolation when used with default settings. Got suggestions from Steve Piper using Nearest-Neighbor interpolation (&amp;quot;no interpolation&amp;quot;) for a time being&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
- This is the new project candidate. Requested for the images with failed manual segmentation and/or segmentation with FreeSurfer. The EM Segmentation run showed most acceptable results on one of the problem images back in February &amp;lt;br&amp;gt;&lt;br /&gt;
- The workflow will be developed and deployed similar to PET/CT ROI Longitudinal study approach - all preprocessing steps will be done with Slicer modules, all runs will be performed on local end-user machines.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
 &lt;br /&gt;
&lt;br /&gt;
* August 15 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- First 5 cases with 3-4 time points preprocessed for SUVs computation&lt;br /&gt;
&lt;br /&gt;
* August 8 2010&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Testing of installation and operation at users' site (Performed by Wendy Plesniak)&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* July 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Delivered beta version of registration pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
- Prepared installation and user manuals &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* June 11, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Registration modules completed &amp;lt;br&amp;gt;&lt;br /&gt;
- Irregular cases registration problem solved (when whole body and brain only scans are mixed for a timepoint)&amp;lt;br&amp;gt;&lt;br /&gt;
- Live demo of case setup and registration workflow for end users. Real case with 4 timepoints used&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Coming week plans&amp;lt;br&amp;gt;&lt;br /&gt;
- Adjust workflow based on end users' feedback&amp;lt;br&amp;gt;&lt;br /&gt;
- Integration with SUVs computing for PET scans&amp;lt;br&amp;gt;&lt;br /&gt;
- GUI for workflows dispatching and data organizing&amp;lt;br&amp;gt;&lt;br /&gt;
- (TBD) Integration with 4D time series analysis Slicer module&amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
* May 28, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- Migration to the latest Slicer 3.6 release candidate &amp;lt;br&amp;gt;&lt;br /&gt;
- Added webservice for new registration module: BRAINSFit &amp;lt;br&amp;gt;&lt;br /&gt;
- Test runs for new patients with 4 timepoints' scans &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Plans for next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI &amp;lt;br&amp;gt;&lt;br /&gt;
- processing workflow demo for end user &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 21, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Pilot version of portable web services and automated workflow tested: &amp;lt;br&amp;gt;&lt;br /&gt;
Linux: workflow and visual review passed&amp;lt;br&amp;gt;&lt;br /&gt;
Stress test for 25 timepoints passed &amp;lt;br&amp;gt;&lt;br /&gt;
MAC OS: workflow passed, visual review failing when PET/CT images are loaded into GUI simultaneously (bug report submitted)&amp;lt;br&amp;gt;&lt;br /&gt;
Windows: need to adapt command line modules and workflow management system to sygwin environment&amp;lt;br&amp;gt;&lt;br /&gt;
Plans for next week: integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI&lt;br /&gt;
&lt;br /&gt;
* May 7, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Selected registration and resampling modules with more precise and stable outputs. &amp;lt;br&amp;gt;&lt;br /&gt;
Started building portable web services and automated workflow &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 30, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- manual walk through the processing steps: ROI cropping, registration/resampling, PET pharmaceutical DICOM data retention. &amp;lt;br&amp;gt;&lt;br /&gt;
- testing workflow and web services packages distribution to end-users' machines&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* April 23, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : testing various registration and re-sampling algorithms (work in progress)&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation: as of collaborators' request, run existing EM Segmentation workflow for older low resolution pseudo-T1 images. The EM Segmentation works for those images with manual sampling. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 16, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
  Social Cognition Study: started Cortical Thickness Measurement module build (bases on NA-MIC ARCTIC pipeline) &amp;lt;br&amp;gt;&lt;br /&gt;
  PET/CT ROI/Longitudinal Study Registration : Design specs, PET-to-CT images registration tests on training data. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 9, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. GUI update based on end-user experience.&amp;lt;br&amp;gt;&lt;br /&gt;
User request: automated label maps' volumes calculation (Currently possible from Slicer3 GUI)&amp;lt;br&amp;gt; &lt;br /&gt;
PET/CT ROI Project. Initial design specs discussion with end-users and co-developers&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure&lt;br /&gt;
Verification of segmentation workflow GUI: from registering new case to reviewing results&amp;lt;br&amp;gt;&lt;br /&gt;
Cross study test of segmentation workflow: MGH/MS Center data - success,  HIV Project data - some EM Segmentation scene tuning is needed &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*&lt;br /&gt;
* April 2, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. Segmentation workflow completed&amp;lt;br&amp;gt;&lt;br /&gt;
* Coming Week plans:&amp;lt;br&amp;gt;&lt;br /&gt;
- Document Segmentation Workflow. Follow up with end users &amp;lt;br&amp;gt;&lt;br /&gt;
- Start with Cortical Thickness and ROI-in-longitudinal studies workflows&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* March 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All essential processing and workflow interaction clients are ready.&amp;lt;br&amp;gt;&lt;br /&gt;
- Completed segmentation for 10 out of 50 patients. The remaining cases will be finalized upon manual lesion segmentation and QC verification of WM/GM/CSF and Deep GM segmentation's. &amp;lt;br&amp;gt;&lt;br /&gt;
- TODO next week: refine QC GUI and data tracking / progress monitoring schema. &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&amp;lt;br&amp;gt;&lt;br /&gt;
- New Slicer3 web services added: re-slicing with reference image volume, casting image scalar type &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
* March 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Segmentation maps Merging Services for GM/WM/CSF (Slicer EM Segemnter), Lesion (Slicer, Manual), and Deep GM (FreeSurfer)  &amp;lt;br&amp;gt;&lt;br /&gt;
- Deep GM segmentation pipeline adopted as optional service for Social Cognition Study (22 out of 50 cases processed) &amp;lt;br&amp;gt;&lt;br /&gt;
- (In progress) GUI client for Launching Segmentation results merging with optional Deep GM segmentation with FreeSurfer &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- Complete GUI Client for Segmentation result merging &amp;lt;br&amp;gt;&lt;br /&gt;
- Progress Monitoring services for entire Study processing: EM Segmenter Preprocessing, EM Segmentation, Lesion Segmentation (including human activities assignments), Deep GM segmentation, and results consolidation. &amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* March 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All 50 cases went through &amp;quot;basic&amp;quot; One-channel EM segmentation (GM/WM/CSF) &amp;lt;br&amp;gt;&lt;br /&gt;
- Basic pipeline start-up command line client created: user has two options - request brainmask extraction or provide with previously extracted brainmask for a given subject &amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison of GM/WN/CSF performed for Slicer EM Segmenter and FreeSurfer recon-all (used with default settings). &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmenter provides more accurate output &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmentation pipeline runs faster (40 minutes vs 12 hrs when no brainmask extraction requested) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO:&amp;lt;br&amp;gt;&lt;br /&gt;
- merging modules for automatic 1-channel EM segmentation and manual lesion segmentation &amp;lt;br&amp;gt;&lt;br /&gt;
- Emerge Cortical Thickness pipeline project: use NAC ARCTIC processing steps and modules &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Selected stable EM Segmentation scenario: White Matter, Gray Matter, and Cerebrospinal Fluid &amp;lt;br&amp;gt;&lt;br /&gt;
- First 16 cases are segmented for selected scenario. Nine more cases are preprocessed for EM Segmentation.&amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison to segmentation with FreeSurfer showed better accuracy for Slicer2 EMSegmenter &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure &amp;lt;br&amp;gt;&lt;br /&gt;
- Three prerpcocessed cases failed during volume ICC masking with in-house build utility. Evaluated switching to Slicer3 Mask and island removing modules.&amp;lt;br&amp;gt;&lt;br /&gt;
- Initial design specs discussion for cortical thickness measurement pipeline. ARCTIC pipeline selected. ARCTIC preprocessing steps signifficantly overlap with EM Segmentation preprocessing workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
  &lt;br /&gt;
* February 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: &amp;lt;br&amp;gt;&lt;br /&gt;
A) parameters tuning for EM Segmenter itself (work with EM Segmenter developer), template scenes creation &amp;lt;br&amp;gt;&lt;br /&gt;
B) update preprocessing pipeline - deep gray matter atlases included &amp;lt;br&amp;gt;&lt;br /&gt;
C) test and debug preprocesing pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
D) identified missing modules: atlas autocalibration for EM Segmentation scene, Island removal for ICC mask&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- Review currently deployed modules. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: reviewed firts seven subjects' outputs, added volume orientation module into pipeline (prevents ICBM atlas linear registration failures)&amp;lt;br&amp;gt;&lt;br /&gt;
- Fused ICC(brainmask) extraction module with EM Segmenter preprocessing. Three scenarious implemented: start with pre-extracted ICC mask (longitudinal studies case), run with ICC ectration, run with ICC extraction AND ICC correction before ICBM atlas preporcessing. &amp;lt;br&amp;gt;&lt;br /&gt;
- Completion of Human activities GUI (QC, ICC Correction) planned for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: Volume Orientation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: automated preprocessing pipeline for Slicer2 EM Segmenter test version deployed. Seven cases pre-processed.&lt;br /&gt;
- PET Quantitative measurements: Preliminary design specs discussion.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: BSplineRegistration (for non-linear registration), ResampleVolume2 (for atlases resampling based on image atlase templates registration). Local and Network runs are implemented, Cluster/GridWizard implementation pending.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Slicer EM Segmenter module: preprocessing design for Slicer2 EM Segmenter&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Adapting for Slicer2 EM Segmenter (mostly from pipelines and services for previous projects)&lt;br /&gt;
  -- Integration with FreeSurfer modules for bisafield correction, brainmask extraction, and linear registration of ICBM atlases&lt;br /&gt;
  -- Preprocessing updates for non-linear registration of ICBM atlases with Slicer2 (image re-orientation service designed)&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 29, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- EM Segmentaton pipeline: preprocessing results are being transferred to XNat (anonymized data, Central XNat) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Slicer EM Segmenter module: discussed agenda and scheduled a work meeting for Social Cognition Study image segmentation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Testing stage, 95% completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- SPL XNat server: verified data exchange via RESTfull web services.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 22, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Follow up with White Matter Lesion Segmenter and Scull Stripping Modules developers: Work in Progress&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Work in Progress, 60%+ completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Discussed SPINE image repository migration to XNat&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 15, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. &lt;br /&gt;
- Social Cognition Study: &lt;br /&gt;
Work-in-progress on intermediate (reconstruction) and results (resources) data storage at XNat.&lt;br /&gt;
&amp;lt;br&amp;gt;Reviewing and preparation more cases for EM Segmentor (Slicer 3.5) tuning.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* NA-MIC Project Week&lt;br /&gt;
Selecting candidate Slicer modules for other than Lesion EM Segmentation topics of Social Cognition study: Withe Matter Lesion Segmenter (UNC), Scull Stripping utility from UIOWA.&lt;br /&gt;
Reviewing issues of currently used Scull Stripping Slicer Extension and Slicer 3.5 EM Segmenter.&lt;br /&gt;
&amp;lt;br&amp;gt;XNat Data organizing training&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 1, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Preparation of Demo for NA-MIC work week: &lt;br /&gt;
- COPD Study. Added Remote pipepline start interface (represents real world scenario where Xnat repository, Processing modules and User are at different sites)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
- EM Segmentation. Added human activities steps to the workflow: ICC (brainmask) correction and EM Segmantation scena load per se.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 25, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Pilot workflow pipeline for EM Segmentation (all steps except user-activity step: ICC correction assignment and tracking)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 18, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Build and tested web services for EM Segmentation image preprocessing: DICOM-to-NRRD conversion, registration, skull stripping, image masking.&lt;br /&gt;
Started building workflow pipeline (subject to finish first version next week)&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Started Collecting Library of Slicer Build number vs. functional modules and extensions.&lt;br /&gt;
Plan for NAMIC project week: scheduled meetings for XNat data customization, Skull-stripping modules tuning, identified Social Cognition study cases that fail EM Segmentation processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 11, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Updating and verification of EM Segmentation Scenario&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Projects:ARRA:SlicerWF:UseCaseScenarios#Usecase_MS_lesion_Assessment&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Familiarizing with Slicer3.4/5 Modules required for implementation of EM Segmentation Scenario. Participation in debugging and/or usage tuning of Dicom Conversion, Registration, Skull Stripping, Masking, and Image Casting modules. &lt;br /&gt;
&lt;br /&gt;
* December 4, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Slicer3.4's EM Segmentation and Visual QC as part of image processing pipeline for Social Cognition Study for MS Patients.&lt;br /&gt;
Project emerged. EM Segmentation template creation debugged.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
Emphysema Measurements (COPD Study) - workflow stability and scalability test.&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 27, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Emphysema Measurements (COPD Study).&lt;br /&gt;
Added compensation for long running calculations and time-outs to the main computing pipeline.&lt;br /&gt;
Visual QC (work in progress)&lt;br /&gt;
** Infrastructure&lt;br /&gt;
XNat data structure customization, metadata storage, results consolidation: new feature request list creation (work in progress)&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 13, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
*** Pilot system for whole processing cycle for Emphysema Measurements (COPD Study) including the following:&lt;br /&gt;
Web query for CT session file list download&lt;br /&gt;
Pilot user interface for submitting the file list and starting processing pipeline&lt;br /&gt;
Notification about processing steps and failures&lt;br /&gt;
Upload results to XNat repository (at this stage results are uploaded into same folder where original scans are(*))&lt;br /&gt;
*** Immediate Plans&lt;br /&gt;
Complete Visual QC module&lt;br /&gt;
Design and implement meta-data transfer to XNat (including processing details and MRML files for loading images into the 3D Slicer)&lt;br /&gt;
&lt;br /&gt;
(*)Customization of results storage&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 6, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Tuned and debugged multiple subjects processing for: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat.&lt;br /&gt;
***Started working on quality control embedding into the above scenario. Plan to complete and video-record demo next week.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***Published general Product Integration scenario flow chart to collaborators' community. Discussion is open and in progress&lt;br /&gt;
&lt;br /&gt;
* October 30, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Piloted and tested the sequence: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat(1).&lt;br /&gt;
***Performance test of overall cycle: data transfer from remote serve is a bottleneck as expected&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data browsing features reviewed.&lt;br /&gt;
(1) Not automated yet&lt;br /&gt;
* October 23, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Defined COPD processing scenario with interoperability between Xnat, 3D Slicer Command Modules, Workflow, and Gridwizard Enterprise.&lt;br /&gt;
***Pilot version of Emphysema Measurements workflow pipeline deployed.&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data transfer features reviewed. Use account at XNat Central during learning curve.&lt;br /&gt;
***Feasibility test of 3D Slicer fiducials module for ROI highlights during QC and manual image processing activities. &lt;br /&gt;
* October 16, 2009&lt;br /&gt;
**Lung CT Scans Processing. Pilot project emerged. GenerateEmphysemaMeasurements module deployed as a webservice that submits jobs to computational cluster.&lt;br /&gt;
**EM Segmentation. Familiarized with GUI steps. Started working on automation steps outlining&lt;br /&gt;
**3D Slicer and XNat interaction. Got an overview from Wendy Plesniak.&lt;br /&gt;
* October 1 - 7, 2009&lt;br /&gt;
**Selected two first priority Projects: EM Segmentation of brain MRI images; Lung CT Scans Processing (COPD Study)&lt;br /&gt;
**Got initial outline of user requirements and design specs&lt;/div&gt;</summary>
		<author><name>Azaitsev</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=66949</id>
		<title>Projects:ARRA:SlicerWF</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=66949"/>
		<updated>2011-05-01T17:47:50Z</updated>

		<summary type="html">&lt;p&gt;Azaitsev: /* Progress */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Projects:ARRASuplements|Back to Slicer ARRA home page]]&lt;br /&gt;
= Aim =&lt;br /&gt;
Supplement 3D Slicer and Extensible Neuroimaging Archive Toolkit (XNAT) with workflow management system. Provide integration and interoperability between 3D Slicer, XNAT Services and 3-rd party image processing applications and high performance computing systems. Implement it as within currently developed Structural Planning and Implementation in Neurological Exploration (SPINE) System.&lt;br /&gt;
&lt;br /&gt;
= SPINE Project Documentation =&lt;br /&gt;
[http://cni.bwh.harvard.edu/projects/spine/index.html SPINE Docs]&lt;br /&gt;
&lt;br /&gt;
= Presentations =&lt;br /&gt;
* Segmentation Workflow. PECS University Social Cognition Study.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:SlicerWF_NAC_PECS_Workflow.pdf]]&lt;br /&gt;
* EAB10_ARRA Annual Progress Report Slides.&amp;lt;br&amp;gt;&lt;br /&gt;
[[media:EAB10_ARRA_WF_2011_Zaitsev.ppt | Service Oriented Solutions for 3D Slicer. EAB10_ARRA_WF_2011. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:EAB10_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:NAMIC_ARRA_WF_2011_Zaitsev.ppt  | NAMIC Annual Report 04/2010-03/2011. NAMIC_ARRA_WF_2011_Zaitsev. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:NAMIC_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:Slicer_WF_Slicer4CARMAWorkflow.ppt  | CARMA Workflow. Cardiac Ablation Followup. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:Slicer_WF_Slicer4CARMAWorkflow.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Segmentation Workflows: Screenshots, scans' and study description : [[File:SlicerWF_EMSegmentProjectsReview.zip]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
= All Hands Meeting Pages =&lt;br /&gt;
* Salt Lake City 2011 Winter [http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA SLC_2011_WorkFlow]&lt;br /&gt;
* MIT 2010 Summer [http://wiki.na-mic.org/Wiki/index.php/Summer_project_week_2010_Workflows_SOA MIT_2010_WorkFlow]&lt;br /&gt;
&lt;br /&gt;
= Research Plan =&lt;br /&gt;
*Create a stand-alone SPINE desktop agent with fully functional data exchange and communication mechanisms towards 3D Slicer and XNAT.&lt;br /&gt;
*Develop Service Oriented Architecture (SOA) SPINE System that will include 3D Slicer image processing modules deployed as web services as well as a workflow management system to orchestrate interaction between 3D Slicer, XNAT, and 3-rd party tools.&lt;br /&gt;
*Implement two-way control and communications between 3D Slicer and SPINE modules.&lt;br /&gt;
*Adapt SPINE System for cluster and grid computing scenarios.&lt;br /&gt;
*Provide with workflow and 3D Slicer web service wrappers editing tools.&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:UseCaseScenarios| Use Case scenarios]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PETCTWorkflow| PETCTWorkflow]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:AgingStudySegmentation| AgingStudySegmentation]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:TwoTensorTractography| TwoTensorTractography]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:LongitudinalMultimodalityRegistrationSuite| LongitudinalMultimodalityRegistrationSuite]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:MigrationJavaClients2QT| MigrationJavaClients2QT]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PediatricMSSegmentation| PediatricMSSegmentation]]&lt;br /&gt;
*[[DBP3:Utah:RegSegPipeline| MRI-based study and treatment of atrial fibrillation]]&lt;br /&gt;
&lt;br /&gt;
= Application Server / Workflow Engine Downloads =&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:WFEngineDownloads| Download Links]]&lt;br /&gt;
&lt;br /&gt;
=Key Personnel=&lt;br /&gt;
* Charles Gutmann, MD., 4%,  9-17-2009 through 9-16-2011&lt;br /&gt;
* Alexander Zaitsev, Ph.D., 75%, 9-17-2009 through 9-16-2011 &lt;br /&gt;
&lt;br /&gt;
=Annual Progress Statements =&lt;br /&gt;
'''2010-11''' &amp;lt;br&amp;gt;&lt;br /&gt;
The  April 2011 – March 2011 period was devoted on developing portable workflow solutions that can be deployed on end-users' workstations or notebooks with minimal or no system administration activities. This is in contrast to the server-side deployment. The following scenarios had been deployed and used for actual projects that require the following types of workflows: PET/CT registration and computation of biomarker driven brain physiological activities, Brain MRI Images segmentation,  MRI and MRI Angiography images pre-processing for cardiac ablation outcome estimation. Some  workflows (like EM Segmentation) had been utilizing various scenarios, some research projects  (like evaluation of chemotherapy outcome) require two types of workflows to assess physiological and structural changes. Starting from the 4th Quarter of 2011, the migration project had been emerged in order to embed Workflow GUIs into newly developed Slicer4 Suite. The existing rich client Java GUI applications are being re-written as C++/QT Sliceletts units, new modules (such as cardiac ablation project support) are had been written from scratch. The latter are being deployed from the Slicer4 GUI and act at a liaison between Slicer4 and Application Server containing  workflow and Slicer modules deployed as services. The feedback from the end users indicates that Workflow approach for the complex processing improves productivity, aids to the processing standardization and contributes to the overall experience using 3D Slicer&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
=Quarterly Progress=&lt;br /&gt;
&lt;br /&gt;
* NAMIC Annual Progress Slides (April 2010 - March 2011):&lt;br /&gt;
&lt;br /&gt;
* '''1st Qtr, 2011''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study: Second release is under testing by end-users. &lt;br /&gt;
*** Added MRI registration to aid ROI drawing on PET scans&lt;br /&gt;
*** Improved SUV results reporting and added flexibility to update ROI lookup table&lt;br /&gt;
*** Automated EM Segmentation of MRI images for computing SUVs for white matter, CSF, and whole brain (80% completion)&lt;br /&gt;
*** Integration with SPECTRE scull stripping module (70% completion) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** EM Segmentation: Automated WF Pipelines are created &amp;lt;br&amp;gt;&lt;br /&gt;
*** Flexible atlas selection (Pediatric, etc) feature added&lt;br /&gt;
*** Workflows implemented for EM Segmenter 3.6.2 and 3.6.3 (1st Qtr 2011 release)&lt;br /&gt;
&lt;br /&gt;
** Cardiac ablation results follow-up: Workflow for registration and ROI selection of cardiac MRI and MR Angiography &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Wrokflow and Web Services for prospective DTI tractography modules (currently written as Matlab modules at PNL) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Web Services for SPECTRE Scull stripping module&lt;br /&gt;
*** Accuracy and performance tuning&lt;br /&gt;
*** 50% completion&lt;br /&gt;
&lt;br /&gt;
** Migration Front End GUI to Slicer4/QT:&lt;br /&gt;
*** EM Segmentation&lt;br /&gt;
*** Cardiac Ablation Study&lt;br /&gt;
&lt;br /&gt;
** DICOM Uploader and Desktop Browser for XNat Image repository (alpha version - tested for MGH MS Center studies, proposed to use with MI2B2 Clients and Services)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''4th Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study and EM Segmentation for Aging Study are deployed at end-user sites and actively used for research. &lt;br /&gt;
** Adopted EM Segmentation preprocessing pipeline for HIV Study: high resolution SPGR images, integration with FreeSurfer brainmask extraction outputs; integration of Slicer SPECTRE module for brainmask extraction is in progress.&lt;br /&gt;
** The following post-release upgrades had been implemented based on end-user feedback: Application Server basic controls are performed from Rich Client GUI as alternative to traditional IT administration activities. The controls are implemented on point-and-click bases and include web services and workflow application deployment and upgrades, application server start and stop as well as warning end user when the server is not accepting request.&lt;br /&gt;
** Added DICOM downloads and results uploads of PET/CT pipelines from and to XNat Repository&lt;br /&gt;
** Created Services and Workflow for Matlab Prototypes modules. Case Study: tractography for DTI images&lt;br /&gt;
** Extended XNAT integration services:&lt;br /&gt;
*** Browsing capabilities of XNat data repository from the Workflow Applications&lt;br /&gt;
*** Improved DICOM upload and download performance&lt;br /&gt;
*** Added Metadata organizing services for uploaded DICOM images: header data extraction, image snapshots creation. &lt;br /&gt;
** Started project for Rich Client GUI migration from Java desktop application to build into SLicer4 QT modules. This affects mostly front-end GUI and has the following approaches: distribution with the Slicer4, end-user will select desired workflow application from Slicer4 menu while QT-written modules provide with the same functionality as Java Rich Clients. Case Study for the Migration process: registration suite for longitudinal studies that include multi-modality images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* '''3d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Concentrated on building downloadable workflow applications that could run both in desktop (new) and server environment, and that require minimum IT administrative resources. The desktop deployment is in compliance with Slicer3 general deployment concept.&lt;br /&gt;
*** The following use case scenario had been chosen: PET/CT image processing for longitudinal studies, EM Segmentation for longitudinal Aging Study.&lt;br /&gt;
** Released workflow application for PET/CT image processing for longitudinal studies. Provided end users with training and documentation.&lt;br /&gt;
*** The PET/CT processing workflow was designed to be a general application used whenever both structural patterns and metabolic activities are within the research scope. &lt;br /&gt;
*** The desktop version is tuned to use minimal computer resources, so the automates processing instances do not interfere with human activities. Automated activities may include, for example, registration and PET scan's standard uptake values computing, and manual human activities may include image cropping, quality control, and labeling voxels of interest.&lt;br /&gt;
** Core services and EM Segmentation preprocessing workflow was build for retrospective Aging Study. Tuned the Slicer3 webservices for processing low grade images acquired in mid 90s. Entire workflow is implemented with Slicer3 only modules and can be deployed locally and on the servers. Usage of Service Oriented Architecture (SOA) as a core technological approach allowed reusing most of the web services that had been build for PET/CT project. &lt;br /&gt;
** Continued embedding Slicer3 application and modules into previously released processing pipelines: replaced MIPAV with Slicer3 GUI for lesion assessment step in the multi-center Pediatric MS Cohort image processing &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''2d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Completed Social Cognition Workflow Implementation. This includes EM Segmetnation pre- and post-processing pipelines, data tracking, and integration with 3d party image processing utilities, as well as processing results acquired manually with Slicer GUI.  &lt;br /&gt;
** Multi-modality image registration and ROI selection/alignment workflow for longitudinal studies. &lt;br /&gt;
*** Use case: PET/CT image processing for longitudinal studies. &lt;br /&gt;
*** Build portable library of Slicer modules as web services and workflow that are deployed and run on a end-users' worksatations without utilization of SPL and other servers. The web services include novel Slicer3 modules, such as BRAINSFit and BRAINSResamle &lt;br /&gt;
*** Started working with Slicer3 developers on Slicer 3.8 GUI wizard to communicate with workflow instances.&lt;br /&gt;
** Participated at NA-MIC Summer 2010 Project Week: [[Summer_project_week_2010_Workflows_SOA]]&lt;br /&gt;
&lt;br /&gt;
=Progress=&lt;br /&gt;
* April 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Open Discussion for Packaging WF QT Modules as Slicer4 extensions (waiting for SOPs)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review supported projects http://wiki.na-mic.org/Wiki/index.php/File:SlicerWF_EMSegmentProjectsReview.zip &lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (required by Study)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Slicer Modules General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Standardizing Crop Volumes Output (with A. Fedorov's module)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 22, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Beta release ready. Demo Location: http://cni29.bwh.harvard.edu/SlicerWFDemo/index.php&lt;br /&gt;
* TODO: Tutorial. Original inputs copy/renaming&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 15, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Adding App server auto-config features&lt;br /&gt;
* Finalizing the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 08, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Second release beta build tested on cosutmer side &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review registration quality (with Dr. Meier). Angiography images' Resampling tuned. &lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 01, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the second release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
XNat Integration&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* (Java) GUI for Project Browsing and DICOM Series Upload. Post-upload DICOM processing tested and debugged&amp;lt;br&amp;gt;&lt;br /&gt;
* Ready for integration with mi2b2 client.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Migrated to Latest Slicer 3.6.3 stable release: only the Input scene had to be updated, the API remained the same&lt;br /&gt;
* Tested EM Segmenter with CMTK4Slicer extension - processing takes to much time on Linux_64bit machine, rolled back to BRAINSFit registration. When used on Mac OS X build, the Slicer could not start (bug report 1126).&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SPECTRE Scull Stripping:&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Testes for various use cases: the module is extremely sensitive to T1 MRI quality (does not work for most MRIs from PET/CT project&lt;br /&gt;
* TODO next week: check for FLAIR images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Slicer4 QT GUI and Cropping activity in progress.&amp;lt;br&amp;gt;&lt;br /&gt;
* Tried direct MRA to MRA registration option: resampling with LMRI registration transforms works better.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Extra VOI labels revised&lt;br /&gt;
* Debugging of SUV results' renormalization step&lt;br /&gt;
* TODO: ICC extraction / whole brain total uptake computing; EM Segmentation for R_WM, L_WM SUV computing and BPH estimation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SCULL STRIPPING/SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Installed and tested CLI option on Linux_64bit platform&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Workflow interruption before BSPline registraton: BPEL Module completed. Slicer4 QT GUI and Cropping activity in prorgess.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Implemented and Tested with end-users proposed changes: denormalization of SUV results, adding more VOI labels, added FLAIR MRI in addition to T1s for VOI drawing&lt;br /&gt;
* Tested manual ICC extraction using PET scans: works satisfactory with island removal and cropping followed by threshold level labeling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4&lt;br /&gt;
* Change proposed: interrupt workflow after affine registration and have user crop the VOI. This is to prevent excessive deformations for BSpline registration and resampling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4. User has option to choose the atlas that fits better for the given subject (NOTE: hardcoding must be rewritten for atlas linking)&lt;br /&gt;
* PETCT test - the problem is that T1s are low resolution and with contrast. Proposed using T1s without contrast&lt;br /&gt;
* PETCT change request: users wants to compute SUV for entire ICC. Had demo how to segment brainmask/ICC using PET scan. The derived brainmask label can be used for SUV computation.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - cmpleted&lt;br /&gt;
* Sample cases run - excessive deformation after BSpline registration hase&lt;br /&gt;
* Next week plan - pull tuning controls to front-end of pipeline API, start working of QT module for CARMA registration&lt;br /&gt;
* May consider other than BRAINSFit registration modules&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Design plan for change request: more VOI labels, add FLAIR in addition to T1 for VOI drawing, T1s segmentation&lt;br /&gt;
* Tested segmentation for sample cases - artifacts from poor quality MRIs lead to exclusion of parts of ICC from segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Completed troubleshooting of EMSegmenter module calling from Java (need TCL libs to be pulled from Slicer environment)&lt;br /&gt;
* Tested EMSegmenter autoruns for HIV and Pediatric MS patiens. Work as expected, subject to improvement of PED MS case segmentation by building better skull/neck/air atalses&lt;br /&gt;
* Suggested usage of two subsets of atalases: with and without neck. The Subject MRIs have to be cropped accordingly or best fit atlas has to be selected&lt;br /&gt;
* Made no-neck cropped atlas collection for default EMSegmenter scenario&lt;br /&gt;
* Tested with PET/CT study MRI cases - see above &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - in progress&lt;br /&gt;
* Next week goal - have back end processing ready&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Longitudinal Study&lt;br /&gt;
* Added MRI registration to the pipeline&lt;br /&gt;
* Troubleshooting of complex XML schema issues on Linux machines (some modules working on MAC do not work on Linux). As a workaround - did not include MRI convert and register part into base BPEL module. Used separate services (transparent for end-user)&lt;br /&gt;
* TODO next week for change request completion: explicit pixel type casting for MRI in BRAINSFit, VOI MRML scene update (currently MRI added on top of schema)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* February 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipeline for Pediatric MRI. Same scenario as for HIV Project, icbm pediatric atlases (Completed, verified)&lt;br /&gt;
* Collected NIH healthy brain development atlases: various age ranges from 4.5 to 18 yo. Converted to Slicer readable format &lt;br /&gt;
* Work on web services for the new automated EM Segmenter module (release Nov 10 - current). Verified task completion both for adult and pediatric images. Discussed tuning parameters for work load balance on workstations.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Started working on MRI registration to the reference CT scans. &lt;br /&gt;
* Design specs for optional White Matter segmentation for SUV computing.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* February 4, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipelines for Pediatric MRI (in progress)&lt;br /&gt;
* Adapting Pediatric T1 atlases for &amp;quot;Human Brain&amp;quot; build-in EM Segmentation wizard (in progress)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 28, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Verifying EM Segmenter module for latest builds and HIV/PED MS Studies (report pending)&lt;br /&gt;
* Work with SPECTRE module developers with pediatric MRI brainmask extraction&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* January 21, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Compiling plan for WF FrontEnd GUI migration to Slicer4/QT Widgets&lt;br /&gt;
* Preparing for annual progress report&lt;br /&gt;
&lt;br /&gt;
* January 14, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI: Integrated into the Slicer4 as Slicelet (or thin Client)&lt;br /&gt;
* Participation at AHM-2011, discussing integration of SPECTRE module and updated approach to EM-Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA&lt;br /&gt;
&lt;br /&gt;
* January 7, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* HIV project workflow delivered. Major additions relate to user convenience: &lt;br /&gt;
- Project-specific parameter settings, importing T1s and brainmasks from FreeSurfer outputs with conversion to NIFTI, resampling brainmask to original scans and automatied subject addition.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Follow up with end user: need to add MRI scans, if available, addition and registration to CT in order to ease VOI drawings.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
 &lt;br /&gt;
* December 31, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Follow-up with user Experience for AGING Study Segmentation (Positive feedback)&lt;br /&gt;
* Target date for HIV project delivery - next week&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Self-training for QT widget development&amp;lt;br&amp;gt;&lt;br /&gt;
* Outlined Workflow Rich Clients migration strategy from Java to QT/Slicer4:&amp;lt;br&amp;gt;&lt;br /&gt;
** Use Java Stubs (similar to SPECTRE integration) or file binding for envocation of workflow pipelines. (See SOAP remark below)&lt;br /&gt;
** Direct Web Servisec calls must be wrapped into REST protocol. The reason: NON-commerchial QT kit does not include SOAP protocol for web servises.&lt;br /&gt;
** The GUI will be implemented as page widget or QT dialog GUI forms called from within Slicer4.&lt;br /&gt;
** Communications between Slicer4 and WF GUI will be set via child-parent and signal-slot relations&lt;br /&gt;
* Worked on a Prototype for Basic EM Segmentation QT widget (70% complete). Will work on integrtion with SLicer4 during the AHM-2010&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
XNAT Integration&lt;br /&gt;
* Debugged XNAT RESTFul API usage for uplaoding DICOM series followed by header data extraction and image snapshots creation&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Added compensation for failed atlas registration (subject for old poor quality pseudo-T1 images): blank probability maps are created in case of failure.&lt;br /&gt;
* Data preparation module for FreeSurfer data import near completion. Expected time for deployment at end-users workstations - first week of January&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Discussed strategy for EM Segmentation pipeline solutions collection (K. Pohl, R. Kikinis)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* RE-using the same core workflow as for 1-channel EM Segmentation of AGING STUDY cases&lt;br /&gt;
* Added data input preparation module: ICC label mask preparation and skull-stripping based on FreeSurfer brainmask output volume.&lt;br /&gt;
* Two-channel EM segmentation pipeline (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE / GENERAL Development &amp;lt;br&amp;gt;&lt;br /&gt;
* Worked on plans for migrating fro rich workflow Java clients to embedded workflow windows inside the Slicer.&amp;lt;br&amp;gt;&lt;br /&gt;
The embedded workflow management clients are to be implemented with QT/PyQT toolkits&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
INTEGRATION WITH XNAT:&amp;lt;br&amp;gt;&lt;br /&gt;
* Automated DICOM series upload with triggering DICOM headers parsing at XNat site (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress. &lt;br /&gt;
- Results upload to XNat (Completed) &amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat based on user's input (Project + Subject + PET or CT session / scan) (Completed)&amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat - perfomance boosting solution for downloads found , web services services are created, relinking for the client side in progress &amp;lt;br&amp;gt;&lt;br /&gt;
- Xnat querying for subjects and automated subject addition into the workflow (In Progress) &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-segmentation module added for auto correction of segmentation results. Particularly - relabeling CSF voxels segmented as Air inside the intracranial cavity. This was requested by end-users after processing images with zero-signals in CSF voxels &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting automated dual-echo DICOM images conversion and split into two NRRD volumes&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT / EM Segmentation pipeline:&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting memory allocation issues for scull-stripping module SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
COPD Project:&amp;lt;br&amp;gt;&lt;br /&gt;
* Benchmark test for accelerated DICOM downloads from XNat (remoote XNat Central server): we can handle at least 6 cases (4 CT scans in each) per hour, which is compatible with current workload quotes on SPL cluster processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* December 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Deployed Version 1. &amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Test project chosen as a closest match to registration scenario: Pediatric MS Cases from MGH - requires periodic image preview for different &lt;br /&gt;
modalities taken from vaious time points. Label maps for VOIs resampling is also required.&lt;br /&gt;
&lt;br /&gt;
* November 26, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user. Version 1 is complete&amp;lt;br&amp;gt;&lt;br /&gt;
* Started working on integration with XNat&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on input data organizing modules&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 19, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user (70% done)&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Universal Registration Workflow for Longitudinal Studies - design specs in progress&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 12, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Minor tuning to EM Segmentation template as of users' feedback&lt;br /&gt;
* Users started using the workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed input data conversion from Genesis to Slicer native or NIFTI format. Our help may be needed in input data organizing.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Tuned application according to co-laborators (PNL) needs&amp;lt;br&amp;gt;&lt;br /&gt;
* The webservices and BPEL workflow application are tested ready to accept computation requests from PNL case tracking system &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Discussed Universal Registration Workflow for Longitudinal Studies&lt;br /&gt;
* Started the thread about possible cooperation with Children hospital's image processing pipelines and integration with Xnat &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 5, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Webservices and workflow pilot project created and deployed on Psychiatry Neuroimaging Laboratory subnet &amp;lt;br&amp;gt;&lt;br /&gt;
* The V.1.0 deployment is scheduled for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 29, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Most of functionality is completed. Some volume statistics post processing is pending&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL EM SEGMENTATION Pipeline: &amp;lt;br&amp;gt;&lt;br /&gt;
* The SPECTRE scull stripping module. Started integration into EMS workflow. Made some test runs from Slicer GUI&amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Identified as a candidate for Workflow Application&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 22, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* All back-end functionality are implemented&amp;lt;br&amp;gt;&lt;br /&gt;
* EM Segmentation scene usability is confirmed by end-user&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for next week: add Label Statistics computation for CSF/Brain/ICC &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 15, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* The latest (October) builds of Slicer 3.6.2 produced acceptable results. This was verified by the target users. The EM Segmentation will be performed on Slicer 3.6.2 or later&amp;lt;br&amp;gt;&lt;br /&gt;
* The new Web services had been created and added to the pipeline as optional processing steps: Biasfield correction (implement novel N2ITKBiasFieldCorrection module) and Volume's scalar datatype casting (as workaround for Biasfield correction module not preserving image scalar datatype - the bug is filed) &amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed the Front-End GUI design with target users. The design pattern is taken from the PETCT project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 8, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-deployment support. Tuned CT registration as of user's feedback.&lt;br /&gt;
* Adapting to the Single Slicer build: Slicer 3.6.2. Found label duplicates in the label lookup table - will ask user if it's tolerable. Waiting for the Slicer 3.6.2 build that contains all required modules. Rolling back label tag appending code for SUVs - the latest Slicer build appends the tags.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Resumed development. The priorities are set for usage of Slicer 3.6.2 - subject for EM Segmentation scene tuning. Continued coding for Scene creation for Slicer 2.8 - as a backup option for ongoing research project.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 1, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized V1.0 release based on end-user feedback: updates relate mostly to error proofing and SUV values representation&lt;br /&gt;
* Post-deployment support. Users pre-processed first set of patients &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* September 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* System deployed and tested at End Users' site.&amp;lt;br&amp;gt;Users are trained to perform all tasks required by the workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
* Got positive feedback with suggestions on Slicer Scenes' layouts improvement and PET scans' SUV (standard uptake values) results display&lt;br /&gt;
* Two distribution packages are assembled: Lunix and MAC OS versions. The difference in two packages is in specific Slicer3.6/3.7 builds - subject to Slicer Linux builds debugging.&amp;lt;br&amp;gt; As a workaround for Linux deployment - multiple Slicer builds are used to perform various tasks (registration, opening editing scenes in Slicer, SUV computing)&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for coming week - finalize V1.0 release based on end-user feedback&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Embedded SUV computations into the workflow (as system calls - will be translated into web service later)&amp;lt;br&amp;gt;&lt;br /&gt;
* Pre-release demo for end users.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Create and debug EM Segmenter scenes template for Slicer 3.6 and 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* September 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation - workflow pipeline and deployment verified&amp;lt;br&amp;gt;&lt;br /&gt;
* Tested EM Segmentation scenes within Slicer 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
* Started migration of EM Segmentation to Slicer 3.6. Discovered issues had been reported to EM Segmenter module designers &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* August 29 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation completed. Preprocessing Pipleine completed 80% (subject for input registration parameters tuning) &amp;lt;br&amp;gt;&lt;br /&gt;
* Most webservices (for registration and resampling steps) had been taken and re-used from PET/CT ROI/Longitudinal Study - showing the advantage of service-oriented software design and deployment.&lt;br /&gt;
* Continued on distribution and deployment of the service/workflow applications: on PET/CT and AGING STUDY projects.&lt;br /&gt;
&lt;br /&gt;
PEDIATRIC Multiple Sclerosis Cohort. Support of multi-center distributed processing project&amp;lt;br&amp;gt;&lt;br /&gt;
* Introduced Slicer 3.6 for the MS Lesion Assessment step performed at Mayo Clinic. Images are being transferred from image repository at BWH and automatically opened and arranged within Slicer GUI for reading.  This was replacement of Client GUI using MIPAV that stopped working on new computers at Mayo Clinic.&lt;br /&gt;
The images are being loaded via generated MRML Scenes same way as in PET/CT and AGING STUDY projects &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* August 22 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Preprocessing pipeline merge with SUV computations &amp;lt;br&amp;gt;&lt;br /&gt;
- QA for SUVs computation was performed by Wendy Plesniak for images with known uptake values. &amp;lt;br&amp;gt;&lt;br /&gt;
- Discovered that image cropping step (not related to automated registration pipeline and SUVs computing) smoothes the images by doing interpolation when used with default settings. Got suggestions from Steve Piper using Nearest-Neighbor interpolation (&amp;quot;no interpolation&amp;quot;) for a time being&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
- This is the new project candidate. Requested for the images with failed manual segmentation and/or segmentation with FreeSurfer. The EM Segmentation run showed most acceptable results on one of the problem images back in February &amp;lt;br&amp;gt;&lt;br /&gt;
- The workflow will be developed and deployed similar to PET/CT ROI Longitudinal study approach - all preprocessing steps will be done with Slicer modules, all runs will be performed on local end-user machines.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
 &lt;br /&gt;
&lt;br /&gt;
* August 15 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- First 5 cases with 3-4 time points preprocessed for SUVs computation&lt;br /&gt;
&lt;br /&gt;
* August 8 2010&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Testing of installation and operation at users' site (Performed by Wendy Plesniak)&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* July 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Delivered beta version of registration pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
- Prepared installation and user manuals &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* June 11, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Registration modules completed &amp;lt;br&amp;gt;&lt;br /&gt;
- Irregular cases registration problem solved (when whole body and brain only scans are mixed for a timepoint)&amp;lt;br&amp;gt;&lt;br /&gt;
- Live demo of case setup and registration workflow for end users. Real case with 4 timepoints used&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Coming week plans&amp;lt;br&amp;gt;&lt;br /&gt;
- Adjust workflow based on end users' feedback&amp;lt;br&amp;gt;&lt;br /&gt;
- Integration with SUVs computing for PET scans&amp;lt;br&amp;gt;&lt;br /&gt;
- GUI for workflows dispatching and data organizing&amp;lt;br&amp;gt;&lt;br /&gt;
- (TBD) Integration with 4D time series analysis Slicer module&amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
* May 28, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- Migration to the latest Slicer 3.6 release candidate &amp;lt;br&amp;gt;&lt;br /&gt;
- Added webservice for new registration module: BRAINSFit &amp;lt;br&amp;gt;&lt;br /&gt;
- Test runs for new patients with 4 timepoints' scans &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Plans for next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI &amp;lt;br&amp;gt;&lt;br /&gt;
- processing workflow demo for end user &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 21, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Pilot version of portable web services and automated workflow tested: &amp;lt;br&amp;gt;&lt;br /&gt;
Linux: workflow and visual review passed&amp;lt;br&amp;gt;&lt;br /&gt;
Stress test for 25 timepoints passed &amp;lt;br&amp;gt;&lt;br /&gt;
MAC OS: workflow passed, visual review failing when PET/CT images are loaded into GUI simultaneously (bug report submitted)&amp;lt;br&amp;gt;&lt;br /&gt;
Windows: need to adapt command line modules and workflow management system to sygwin environment&amp;lt;br&amp;gt;&lt;br /&gt;
Plans for next week: integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI&lt;br /&gt;
&lt;br /&gt;
* May 7, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Selected registration and resampling modules with more precise and stable outputs. &amp;lt;br&amp;gt;&lt;br /&gt;
Started building portable web services and automated workflow &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 30, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- manual walk through the processing steps: ROI cropping, registration/resampling, PET pharmaceutical DICOM data retention. &amp;lt;br&amp;gt;&lt;br /&gt;
- testing workflow and web services packages distribution to end-users' machines&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* April 23, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : testing various registration and re-sampling algorithms (work in progress)&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation: as of collaborators' request, run existing EM Segmentation workflow for older low resolution pseudo-T1 images. The EM Segmentation works for those images with manual sampling. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 16, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
  Social Cognition Study: started Cortical Thickness Measurement module build (bases on NA-MIC ARCTIC pipeline) &amp;lt;br&amp;gt;&lt;br /&gt;
  PET/CT ROI/Longitudinal Study Registration : Design specs, PET-to-CT images registration tests on training data. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 9, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. GUI update based on end-user experience.&amp;lt;br&amp;gt;&lt;br /&gt;
User request: automated label maps' volumes calculation (Currently possible from Slicer3 GUI)&amp;lt;br&amp;gt; &lt;br /&gt;
PET/CT ROI Project. Initial design specs discussion with end-users and co-developers&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure&lt;br /&gt;
Verification of segmentation workflow GUI: from registering new case to reviewing results&amp;lt;br&amp;gt;&lt;br /&gt;
Cross study test of segmentation workflow: MGH/MS Center data - success,  HIV Project data - some EM Segmentation scene tuning is needed &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*&lt;br /&gt;
* April 2, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. Segmentation workflow completed&amp;lt;br&amp;gt;&lt;br /&gt;
* Coming Week plans:&amp;lt;br&amp;gt;&lt;br /&gt;
- Document Segmentation Workflow. Follow up with end users &amp;lt;br&amp;gt;&lt;br /&gt;
- Start with Cortical Thickness and ROI-in-longitudinal studies workflows&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* March 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All essential processing and workflow interaction clients are ready.&amp;lt;br&amp;gt;&lt;br /&gt;
- Completed segmentation for 10 out of 50 patients. The remaining cases will be finalized upon manual lesion segmentation and QC verification of WM/GM/CSF and Deep GM segmentation's. &amp;lt;br&amp;gt;&lt;br /&gt;
- TODO next week: refine QC GUI and data tracking / progress monitoring schema. &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&amp;lt;br&amp;gt;&lt;br /&gt;
- New Slicer3 web services added: re-slicing with reference image volume, casting image scalar type &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
* March 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Segmentation maps Merging Services for GM/WM/CSF (Slicer EM Segemnter), Lesion (Slicer, Manual), and Deep GM (FreeSurfer)  &amp;lt;br&amp;gt;&lt;br /&gt;
- Deep GM segmentation pipeline adopted as optional service for Social Cognition Study (22 out of 50 cases processed) &amp;lt;br&amp;gt;&lt;br /&gt;
- (In progress) GUI client for Launching Segmentation results merging with optional Deep GM segmentation with FreeSurfer &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- Complete GUI Client for Segmentation result merging &amp;lt;br&amp;gt;&lt;br /&gt;
- Progress Monitoring services for entire Study processing: EM Segmenter Preprocessing, EM Segmentation, Lesion Segmentation (including human activities assignments), Deep GM segmentation, and results consolidation. &amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* March 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All 50 cases went through &amp;quot;basic&amp;quot; One-channel EM segmentation (GM/WM/CSF) &amp;lt;br&amp;gt;&lt;br /&gt;
- Basic pipeline start-up command line client created: user has two options - request brainmask extraction or provide with previously extracted brainmask for a given subject &amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison of GM/WN/CSF performed for Slicer EM Segmenter and FreeSurfer recon-all (used with default settings). &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmenter provides more accurate output &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmentation pipeline runs faster (40 minutes vs 12 hrs when no brainmask extraction requested) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO:&amp;lt;br&amp;gt;&lt;br /&gt;
- merging modules for automatic 1-channel EM segmentation and manual lesion segmentation &amp;lt;br&amp;gt;&lt;br /&gt;
- Emerge Cortical Thickness pipeline project: use NAC ARCTIC processing steps and modules &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Selected stable EM Segmentation scenario: White Matter, Gray Matter, and Cerebrospinal Fluid &amp;lt;br&amp;gt;&lt;br /&gt;
- First 16 cases are segmented for selected scenario. Nine more cases are preprocessed for EM Segmentation.&amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison to segmentation with FreeSurfer showed better accuracy for Slicer2 EMSegmenter &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure &amp;lt;br&amp;gt;&lt;br /&gt;
- Three prerpcocessed cases failed during volume ICC masking with in-house build utility. Evaluated switching to Slicer3 Mask and island removing modules.&amp;lt;br&amp;gt;&lt;br /&gt;
- Initial design specs discussion for cortical thickness measurement pipeline. ARCTIC pipeline selected. ARCTIC preprocessing steps signifficantly overlap with EM Segmentation preprocessing workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
  &lt;br /&gt;
* February 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: &amp;lt;br&amp;gt;&lt;br /&gt;
A) parameters tuning for EM Segmenter itself (work with EM Segmenter developer), template scenes creation &amp;lt;br&amp;gt;&lt;br /&gt;
B) update preprocessing pipeline - deep gray matter atlases included &amp;lt;br&amp;gt;&lt;br /&gt;
C) test and debug preprocesing pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
D) identified missing modules: atlas autocalibration for EM Segmentation scene, Island removal for ICC mask&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- Review currently deployed modules. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: reviewed firts seven subjects' outputs, added volume orientation module into pipeline (prevents ICBM atlas linear registration failures)&amp;lt;br&amp;gt;&lt;br /&gt;
- Fused ICC(brainmask) extraction module with EM Segmenter preprocessing. Three scenarious implemented: start with pre-extracted ICC mask (longitudinal studies case), run with ICC ectration, run with ICC extraction AND ICC correction before ICBM atlas preporcessing. &amp;lt;br&amp;gt;&lt;br /&gt;
- Completion of Human activities GUI (QC, ICC Correction) planned for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: Volume Orientation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: automated preprocessing pipeline for Slicer2 EM Segmenter test version deployed. Seven cases pre-processed.&lt;br /&gt;
- PET Quantitative measurements: Preliminary design specs discussion.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: BSplineRegistration (for non-linear registration), ResampleVolume2 (for atlases resampling based on image atlase templates registration). Local and Network runs are implemented, Cluster/GridWizard implementation pending.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Slicer EM Segmenter module: preprocessing design for Slicer2 EM Segmenter&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Adapting for Slicer2 EM Segmenter (mostly from pipelines and services for previous projects)&lt;br /&gt;
  -- Integration with FreeSurfer modules for bisafield correction, brainmask extraction, and linear registration of ICBM atlases&lt;br /&gt;
  -- Preprocessing updates for non-linear registration of ICBM atlases with Slicer2 (image re-orientation service designed)&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 29, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- EM Segmentaton pipeline: preprocessing results are being transferred to XNat (anonymized data, Central XNat) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Slicer EM Segmenter module: discussed agenda and scheduled a work meeting for Social Cognition Study image segmentation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Testing stage, 95% completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- SPL XNat server: verified data exchange via RESTfull web services.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 22, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Follow up with White Matter Lesion Segmenter and Scull Stripping Modules developers: Work in Progress&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Work in Progress, 60%+ completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Discussed SPINE image repository migration to XNat&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 15, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. &lt;br /&gt;
- Social Cognition Study: &lt;br /&gt;
Work-in-progress on intermediate (reconstruction) and results (resources) data storage at XNat.&lt;br /&gt;
&amp;lt;br&amp;gt;Reviewing and preparation more cases for EM Segmentor (Slicer 3.5) tuning.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* NA-MIC Project Week&lt;br /&gt;
Selecting candidate Slicer modules for other than Lesion EM Segmentation topics of Social Cognition study: Withe Matter Lesion Segmenter (UNC), Scull Stripping utility from UIOWA.&lt;br /&gt;
Reviewing issues of currently used Scull Stripping Slicer Extension and Slicer 3.5 EM Segmenter.&lt;br /&gt;
&amp;lt;br&amp;gt;XNat Data organizing training&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 1, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Preparation of Demo for NA-MIC work week: &lt;br /&gt;
- COPD Study. Added Remote pipepline start interface (represents real world scenario where Xnat repository, Processing modules and User are at different sites)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
- EM Segmentation. Added human activities steps to the workflow: ICC (brainmask) correction and EM Segmantation scena load per se.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 25, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Pilot workflow pipeline for EM Segmentation (all steps except user-activity step: ICC correction assignment and tracking)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 18, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Build and tested web services for EM Segmentation image preprocessing: DICOM-to-NRRD conversion, registration, skull stripping, image masking.&lt;br /&gt;
Started building workflow pipeline (subject to finish first version next week)&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Started Collecting Library of Slicer Build number vs. functional modules and extensions.&lt;br /&gt;
Plan for NAMIC project week: scheduled meetings for XNat data customization, Skull-stripping modules tuning, identified Social Cognition study cases that fail EM Segmentation processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 11, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Updating and verification of EM Segmentation Scenario&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Projects:ARRA:SlicerWF:UseCaseScenarios#Usecase_MS_lesion_Assessment&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Familiarizing with Slicer3.4/5 Modules required for implementation of EM Segmentation Scenario. Participation in debugging and/or usage tuning of Dicom Conversion, Registration, Skull Stripping, Masking, and Image Casting modules. &lt;br /&gt;
&lt;br /&gt;
* December 4, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Slicer3.4's EM Segmentation and Visual QC as part of image processing pipeline for Social Cognition Study for MS Patients.&lt;br /&gt;
Project emerged. EM Segmentation template creation debugged.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
Emphysema Measurements (COPD Study) - workflow stability and scalability test.&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 27, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Emphysema Measurements (COPD Study).&lt;br /&gt;
Added compensation for long running calculations and time-outs to the main computing pipeline.&lt;br /&gt;
Visual QC (work in progress)&lt;br /&gt;
** Infrastructure&lt;br /&gt;
XNat data structure customization, metadata storage, results consolidation: new feature request list creation (work in progress)&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 13, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
*** Pilot system for whole processing cycle for Emphysema Measurements (COPD Study) including the following:&lt;br /&gt;
Web query for CT session file list download&lt;br /&gt;
Pilot user interface for submitting the file list and starting processing pipeline&lt;br /&gt;
Notification about processing steps and failures&lt;br /&gt;
Upload results to XNat repository (at this stage results are uploaded into same folder where original scans are(*))&lt;br /&gt;
*** Immediate Plans&lt;br /&gt;
Complete Visual QC module&lt;br /&gt;
Design and implement meta-data transfer to XNat (including processing details and MRML files for loading images into the 3D Slicer)&lt;br /&gt;
&lt;br /&gt;
(*)Customization of results storage&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 6, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Tuned and debugged multiple subjects processing for: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat.&lt;br /&gt;
***Started working on quality control embedding into the above scenario. Plan to complete and video-record demo next week.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***Published general Product Integration scenario flow chart to collaborators' community. Discussion is open and in progress&lt;br /&gt;
&lt;br /&gt;
* October 30, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Piloted and tested the sequence: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat(1).&lt;br /&gt;
***Performance test of overall cycle: data transfer from remote serve is a bottleneck as expected&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data browsing features reviewed.&lt;br /&gt;
(1) Not automated yet&lt;br /&gt;
* October 23, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Defined COPD processing scenario with interoperability between Xnat, 3D Slicer Command Modules, Workflow, and Gridwizard Enterprise.&lt;br /&gt;
***Pilot version of Emphysema Measurements workflow pipeline deployed.&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data transfer features reviewed. Use account at XNat Central during learning curve.&lt;br /&gt;
***Feasibility test of 3D Slicer fiducials module for ROI highlights during QC and manual image processing activities. &lt;br /&gt;
* October 16, 2009&lt;br /&gt;
**Lung CT Scans Processing. Pilot project emerged. GenerateEmphysemaMeasurements module deployed as a webservice that submits jobs to computational cluster.&lt;br /&gt;
**EM Segmentation. Familiarized with GUI steps. Started working on automation steps outlining&lt;br /&gt;
**3D Slicer and XNat interaction. Got an overview from Wendy Plesniak.&lt;br /&gt;
* October 1 - 7, 2009&lt;br /&gt;
**Selected two first priority Projects: EM Segmentation of brain MRI images; Lung CT Scans Processing (COPD Study)&lt;br /&gt;
**Got initial outline of user requirements and design specs&lt;/div&gt;</summary>
		<author><name>Azaitsev</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=66948</id>
		<title>Projects:ARRA:SlicerWF</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=66948"/>
		<updated>2011-05-01T17:34:45Z</updated>

		<summary type="html">&lt;p&gt;Azaitsev: /* Progress */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Projects:ARRASuplements|Back to Slicer ARRA home page]]&lt;br /&gt;
= Aim =&lt;br /&gt;
Supplement 3D Slicer and Extensible Neuroimaging Archive Toolkit (XNAT) with workflow management system. Provide integration and interoperability between 3D Slicer, XNAT Services and 3-rd party image processing applications and high performance computing systems. Implement it as within currently developed Structural Planning and Implementation in Neurological Exploration (SPINE) System.&lt;br /&gt;
&lt;br /&gt;
= SPINE Project Documentation =&lt;br /&gt;
[http://cni.bwh.harvard.edu/projects/spine/index.html SPINE Docs]&lt;br /&gt;
&lt;br /&gt;
= Presentations =&lt;br /&gt;
* Segmentation Workflow. PECS University Social Cognition Study.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:SlicerWF_NAC_PECS_Workflow.pdf]]&lt;br /&gt;
* EAB10_ARRA Annual Progress Report Slides.&amp;lt;br&amp;gt;&lt;br /&gt;
[[media:EAB10_ARRA_WF_2011_Zaitsev.ppt | Service Oriented Solutions for 3D Slicer. EAB10_ARRA_WF_2011. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:EAB10_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:NAMIC_ARRA_WF_2011_Zaitsev.ppt  | NAMIC Annual Report 04/2010-03/2011. NAMIC_ARRA_WF_2011_Zaitsev. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:NAMIC_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:Slicer_WF_Slicer4CARMAWorkflow.ppt  | CARMA Workflow. Cardiac Ablation Followup. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:Slicer_WF_Slicer4CARMAWorkflow.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Segmentation Workflows: Screenshots, scans' and study description : [[File:SlicerWF_EMSegmentProjectsReview.zip]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
= All Hands Meeting Pages =&lt;br /&gt;
* Salt Lake City 2011 Winter [http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA SLC_2011_WorkFlow]&lt;br /&gt;
* MIT 2010 Summer [http://wiki.na-mic.org/Wiki/index.php/Summer_project_week_2010_Workflows_SOA MIT_2010_WorkFlow]&lt;br /&gt;
&lt;br /&gt;
= Research Plan =&lt;br /&gt;
*Create a stand-alone SPINE desktop agent with fully functional data exchange and communication mechanisms towards 3D Slicer and XNAT.&lt;br /&gt;
*Develop Service Oriented Architecture (SOA) SPINE System that will include 3D Slicer image processing modules deployed as web services as well as a workflow management system to orchestrate interaction between 3D Slicer, XNAT, and 3-rd party tools.&lt;br /&gt;
*Implement two-way control and communications between 3D Slicer and SPINE modules.&lt;br /&gt;
*Adapt SPINE System for cluster and grid computing scenarios.&lt;br /&gt;
*Provide with workflow and 3D Slicer web service wrappers editing tools.&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:UseCaseScenarios| Use Case scenarios]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PETCTWorkflow| PETCTWorkflow]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:AgingStudySegmentation| AgingStudySegmentation]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:TwoTensorTractography| TwoTensorTractography]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:LongitudinalMultimodalityRegistrationSuite| LongitudinalMultimodalityRegistrationSuite]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:MigrationJavaClients2QT| MigrationJavaClients2QT]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PediatricMSSegmentation| PediatricMSSegmentation]]&lt;br /&gt;
*[[DBP3:Utah:RegSegPipeline| MRI-based study and treatment of atrial fibrillation]]&lt;br /&gt;
&lt;br /&gt;
= Application Server / Workflow Engine Downloads =&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:WFEngineDownloads| Download Links]]&lt;br /&gt;
&lt;br /&gt;
=Key Personnel=&lt;br /&gt;
* Charles Gutmann, MD., 4%,  9-17-2009 through 9-16-2011&lt;br /&gt;
* Alexander Zaitsev, Ph.D., 75%, 9-17-2009 through 9-16-2011 &lt;br /&gt;
&lt;br /&gt;
=Annual Progress Statements =&lt;br /&gt;
'''2010-11''' &amp;lt;br&amp;gt;&lt;br /&gt;
The  April 2011 – March 2011 period was devoted on developing portable workflow solutions that can be deployed on end-users' workstations or notebooks with minimal or no system administration activities. This is in contrast to the server-side deployment. The following scenarios had been deployed and used for actual projects that require the following types of workflows: PET/CT registration and computation of biomarker driven brain physiological activities, Brain MRI Images segmentation,  MRI and MRI Angiography images pre-processing for cardiac ablation outcome estimation. Some  workflows (like EM Segmentation) had been utilizing various scenarios, some research projects  (like evaluation of chemotherapy outcome) require two types of workflows to assess physiological and structural changes. Starting from the 4th Quarter of 2011, the migration project had been emerged in order to embed Workflow GUIs into newly developed Slicer4 Suite. The existing rich client Java GUI applications are being re-written as C++/QT Sliceletts units, new modules (such as cardiac ablation project support) are had been written from scratch. The latter are being deployed from the Slicer4 GUI and act at a liaison between Slicer4 and Application Server containing  workflow and Slicer modules deployed as services. The feedback from the end users indicates that Workflow approach for the complex processing improves productivity, aids to the processing standardization and contributes to the overall experience using 3D Slicer&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
=Quarterly Progress=&lt;br /&gt;
&lt;br /&gt;
* NAMIC Annual Progress Slides (April 2010 - March 2011):&lt;br /&gt;
&lt;br /&gt;
* '''1st Qtr, 2011''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study: Second release is under testing by end-users. &lt;br /&gt;
*** Added MRI registration to aid ROI drawing on PET scans&lt;br /&gt;
*** Improved SUV results reporting and added flexibility to update ROI lookup table&lt;br /&gt;
*** Automated EM Segmentation of MRI images for computing SUVs for white matter, CSF, and whole brain (80% completion)&lt;br /&gt;
*** Integration with SPECTRE scull stripping module (70% completion) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** EM Segmentation: Automated WF Pipelines are created &amp;lt;br&amp;gt;&lt;br /&gt;
*** Flexible atlas selection (Pediatric, etc) feature added&lt;br /&gt;
*** Workflows implemented for EM Segmenter 3.6.2 and 3.6.3 (1st Qtr 2011 release)&lt;br /&gt;
&lt;br /&gt;
** Cardiac ablation results follow-up: Workflow for registration and ROI selection of cardiac MRI and MR Angiography &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Wrokflow and Web Services for prospective DTI tractography modules (currently written as Matlab modules at PNL) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Web Services for SPECTRE Scull stripping module&lt;br /&gt;
*** Accuracy and performance tuning&lt;br /&gt;
*** 50% completion&lt;br /&gt;
&lt;br /&gt;
** Migration Front End GUI to Slicer4/QT:&lt;br /&gt;
*** EM Segmentation&lt;br /&gt;
*** Cardiac Ablation Study&lt;br /&gt;
&lt;br /&gt;
** DICOM Uploader and Desktop Browser for XNat Image repository (alpha version - tested for MGH MS Center studies, proposed to use with MI2B2 Clients and Services)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''4th Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study and EM Segmentation for Aging Study are deployed at end-user sites and actively used for research. &lt;br /&gt;
** Adopted EM Segmentation preprocessing pipeline for HIV Study: high resolution SPGR images, integration with FreeSurfer brainmask extraction outputs; integration of Slicer SPECTRE module for brainmask extraction is in progress.&lt;br /&gt;
** The following post-release upgrades had been implemented based on end-user feedback: Application Server basic controls are performed from Rich Client GUI as alternative to traditional IT administration activities. The controls are implemented on point-and-click bases and include web services and workflow application deployment and upgrades, application server start and stop as well as warning end user when the server is not accepting request.&lt;br /&gt;
** Added DICOM downloads and results uploads of PET/CT pipelines from and to XNat Repository&lt;br /&gt;
** Created Services and Workflow for Matlab Prototypes modules. Case Study: tractography for DTI images&lt;br /&gt;
** Extended XNAT integration services:&lt;br /&gt;
*** Browsing capabilities of XNat data repository from the Workflow Applications&lt;br /&gt;
*** Improved DICOM upload and download performance&lt;br /&gt;
*** Added Metadata organizing services for uploaded DICOM images: header data extraction, image snapshots creation. &lt;br /&gt;
** Started project for Rich Client GUI migration from Java desktop application to build into SLicer4 QT modules. This affects mostly front-end GUI and has the following approaches: distribution with the Slicer4, end-user will select desired workflow application from Slicer4 menu while QT-written modules provide with the same functionality as Java Rich Clients. Case Study for the Migration process: registration suite for longitudinal studies that include multi-modality images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* '''3d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Concentrated on building downloadable workflow applications that could run both in desktop (new) and server environment, and that require minimum IT administrative resources. The desktop deployment is in compliance with Slicer3 general deployment concept.&lt;br /&gt;
*** The following use case scenario had been chosen: PET/CT image processing for longitudinal studies, EM Segmentation for longitudinal Aging Study.&lt;br /&gt;
** Released workflow application for PET/CT image processing for longitudinal studies. Provided end users with training and documentation.&lt;br /&gt;
*** The PET/CT processing workflow was designed to be a general application used whenever both structural patterns and metabolic activities are within the research scope. &lt;br /&gt;
*** The desktop version is tuned to use minimal computer resources, so the automates processing instances do not interfere with human activities. Automated activities may include, for example, registration and PET scan's standard uptake values computing, and manual human activities may include image cropping, quality control, and labeling voxels of interest.&lt;br /&gt;
** Core services and EM Segmentation preprocessing workflow was build for retrospective Aging Study. Tuned the Slicer3 webservices for processing low grade images acquired in mid 90s. Entire workflow is implemented with Slicer3 only modules and can be deployed locally and on the servers. Usage of Service Oriented Architecture (SOA) as a core technological approach allowed reusing most of the web services that had been build for PET/CT project. &lt;br /&gt;
** Continued embedding Slicer3 application and modules into previously released processing pipelines: replaced MIPAV with Slicer3 GUI for lesion assessment step in the multi-center Pediatric MS Cohort image processing &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''2d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Completed Social Cognition Workflow Implementation. This includes EM Segmetnation pre- and post-processing pipelines, data tracking, and integration with 3d party image processing utilities, as well as processing results acquired manually with Slicer GUI.  &lt;br /&gt;
** Multi-modality image registration and ROI selection/alignment workflow for longitudinal studies. &lt;br /&gt;
*** Use case: PET/CT image processing for longitudinal studies. &lt;br /&gt;
*** Build portable library of Slicer modules as web services and workflow that are deployed and run on a end-users' worksatations without utilization of SPL and other servers. The web services include novel Slicer3 modules, such as BRAINSFit and BRAINSResamle &lt;br /&gt;
*** Started working with Slicer3 developers on Slicer 3.8 GUI wizard to communicate with workflow instances.&lt;br /&gt;
** Participated at NA-MIC Summer 2010 Project Week: [[Summer_project_week_2010_Workflows_SOA]]&lt;br /&gt;
&lt;br /&gt;
=Progress=&lt;br /&gt;
* April 29, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Code Review/Cleaning&lt;br /&gt;
* Open Discussion for Packaging WF QT Modules as Slicer4 extensions (waiting for SOPs)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation General&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review supported projects http://wiki.na-mic.org/Wiki/index.php/File:SlicerWF_EMSegmentProjectsReview.zip &lt;br /&gt;
* Resume EM Segmentation task creation for Left and Right Hemispheres' WM segmentation (required by Study)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 22, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Beta release ready. Demo Location: http://cni29.bwh.harvard.edu/SlicerWFDemo/index.php&lt;br /&gt;
* TODO: Tutorial. Original inputs copy/renaming&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 15, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Adding App server auto-config features&lt;br /&gt;
* Finalizing the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 08, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Second release beta build tested on cosutmer side &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review registration quality (with Dr. Meier). Angiography images' Resampling tuned. &lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 01, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the second release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
XNat Integration&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* (Java) GUI for Project Browsing and DICOM Series Upload. Post-upload DICOM processing tested and debugged&amp;lt;br&amp;gt;&lt;br /&gt;
* Ready for integration with mi2b2 client.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Migrated to Latest Slicer 3.6.3 stable release: only the Input scene had to be updated, the API remained the same&lt;br /&gt;
* Tested EM Segmenter with CMTK4Slicer extension - processing takes to much time on Linux_64bit machine, rolled back to BRAINSFit registration. When used on Mac OS X build, the Slicer could not start (bug report 1126).&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SPECTRE Scull Stripping:&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Testes for various use cases: the module is extremely sensitive to T1 MRI quality (does not work for most MRIs from PET/CT project&lt;br /&gt;
* TODO next week: check for FLAIR images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Slicer4 QT GUI and Cropping activity in progress.&amp;lt;br&amp;gt;&lt;br /&gt;
* Tried direct MRA to MRA registration option: resampling with LMRI registration transforms works better.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Extra VOI labels revised&lt;br /&gt;
* Debugging of SUV results' renormalization step&lt;br /&gt;
* TODO: ICC extraction / whole brain total uptake computing; EM Segmentation for R_WM, L_WM SUV computing and BPH estimation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SCULL STRIPPING/SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Installed and tested CLI option on Linux_64bit platform&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Workflow interruption before BSPline registraton: BPEL Module completed. Slicer4 QT GUI and Cropping activity in prorgess.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Implemented and Tested with end-users proposed changes: denormalization of SUV results, adding more VOI labels, added FLAIR MRI in addition to T1s for VOI drawing&lt;br /&gt;
* Tested manual ICC extraction using PET scans: works satisfactory with island removal and cropping followed by threshold level labeling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4&lt;br /&gt;
* Change proposed: interrupt workflow after affine registration and have user crop the VOI. This is to prevent excessive deformations for BSpline registration and resampling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4. User has option to choose the atlas that fits better for the given subject (NOTE: hardcoding must be rewritten for atlas linking)&lt;br /&gt;
* PETCT test - the problem is that T1s are low resolution and with contrast. Proposed using T1s without contrast&lt;br /&gt;
* PETCT change request: users wants to compute SUV for entire ICC. Had demo how to segment brainmask/ICC using PET scan. The derived brainmask label can be used for SUV computation.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - cmpleted&lt;br /&gt;
* Sample cases run - excessive deformation after BSpline registration hase&lt;br /&gt;
* Next week plan - pull tuning controls to front-end of pipeline API, start working of QT module for CARMA registration&lt;br /&gt;
* May consider other than BRAINSFit registration modules&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Design plan for change request: more VOI labels, add FLAIR in addition to T1 for VOI drawing, T1s segmentation&lt;br /&gt;
* Tested segmentation for sample cases - artifacts from poor quality MRIs lead to exclusion of parts of ICC from segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Completed troubleshooting of EMSegmenter module calling from Java (need TCL libs to be pulled from Slicer environment)&lt;br /&gt;
* Tested EMSegmenter autoruns for HIV and Pediatric MS patiens. Work as expected, subject to improvement of PED MS case segmentation by building better skull/neck/air atalses&lt;br /&gt;
* Suggested usage of two subsets of atalases: with and without neck. The Subject MRIs have to be cropped accordingly or best fit atlas has to be selected&lt;br /&gt;
* Made no-neck cropped atlas collection for default EMSegmenter scenario&lt;br /&gt;
* Tested with PET/CT study MRI cases - see above &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - in progress&lt;br /&gt;
* Next week goal - have back end processing ready&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Longitudinal Study&lt;br /&gt;
* Added MRI registration to the pipeline&lt;br /&gt;
* Troubleshooting of complex XML schema issues on Linux machines (some modules working on MAC do not work on Linux). As a workaround - did not include MRI convert and register part into base BPEL module. Used separate services (transparent for end-user)&lt;br /&gt;
* TODO next week for change request completion: explicit pixel type casting for MRI in BRAINSFit, VOI MRML scene update (currently MRI added on top of schema)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* February 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipeline for Pediatric MRI. Same scenario as for HIV Project, icbm pediatric atlases (Completed, verified)&lt;br /&gt;
* Collected NIH healthy brain development atlases: various age ranges from 4.5 to 18 yo. Converted to Slicer readable format &lt;br /&gt;
* Work on web services for the new automated EM Segmenter module (release Nov 10 - current). Verified task completion both for adult and pediatric images. Discussed tuning parameters for work load balance on workstations.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Started working on MRI registration to the reference CT scans. &lt;br /&gt;
* Design specs for optional White Matter segmentation for SUV computing.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* February 4, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipelines for Pediatric MRI (in progress)&lt;br /&gt;
* Adapting Pediatric T1 atlases for &amp;quot;Human Brain&amp;quot; build-in EM Segmentation wizard (in progress)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 28, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Verifying EM Segmenter module for latest builds and HIV/PED MS Studies (report pending)&lt;br /&gt;
* Work with SPECTRE module developers with pediatric MRI brainmask extraction&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* January 21, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Compiling plan for WF FrontEnd GUI migration to Slicer4/QT Widgets&lt;br /&gt;
* Preparing for annual progress report&lt;br /&gt;
&lt;br /&gt;
* January 14, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI: Integrated into the Slicer4 as Slicelet (or thin Client)&lt;br /&gt;
* Participation at AHM-2011, discussing integration of SPECTRE module and updated approach to EM-Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA&lt;br /&gt;
&lt;br /&gt;
* January 7, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* HIV project workflow delivered. Major additions relate to user convenience: &lt;br /&gt;
- Project-specific parameter settings, importing T1s and brainmasks from FreeSurfer outputs with conversion to NIFTI, resampling brainmask to original scans and automatied subject addition.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Follow up with end user: need to add MRI scans, if available, addition and registration to CT in order to ease VOI drawings.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
 &lt;br /&gt;
* December 31, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Follow-up with user Experience for AGING Study Segmentation (Positive feedback)&lt;br /&gt;
* Target date for HIV project delivery - next week&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Self-training for QT widget development&amp;lt;br&amp;gt;&lt;br /&gt;
* Outlined Workflow Rich Clients migration strategy from Java to QT/Slicer4:&amp;lt;br&amp;gt;&lt;br /&gt;
** Use Java Stubs (similar to SPECTRE integration) or file binding for envocation of workflow pipelines. (See SOAP remark below)&lt;br /&gt;
** Direct Web Servisec calls must be wrapped into REST protocol. The reason: NON-commerchial QT kit does not include SOAP protocol for web servises.&lt;br /&gt;
** The GUI will be implemented as page widget or QT dialog GUI forms called from within Slicer4.&lt;br /&gt;
** Communications between Slicer4 and WF GUI will be set via child-parent and signal-slot relations&lt;br /&gt;
* Worked on a Prototype for Basic EM Segmentation QT widget (70% complete). Will work on integrtion with SLicer4 during the AHM-2010&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
XNAT Integration&lt;br /&gt;
* Debugged XNAT RESTFul API usage for uplaoding DICOM series followed by header data extraction and image snapshots creation&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Added compensation for failed atlas registration (subject for old poor quality pseudo-T1 images): blank probability maps are created in case of failure.&lt;br /&gt;
* Data preparation module for FreeSurfer data import near completion. Expected time for deployment at end-users workstations - first week of January&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Discussed strategy for EM Segmentation pipeline solutions collection (K. Pohl, R. Kikinis)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* RE-using the same core workflow as for 1-channel EM Segmentation of AGING STUDY cases&lt;br /&gt;
* Added data input preparation module: ICC label mask preparation and skull-stripping based on FreeSurfer brainmask output volume.&lt;br /&gt;
* Two-channel EM segmentation pipeline (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE / GENERAL Development &amp;lt;br&amp;gt;&lt;br /&gt;
* Worked on plans for migrating fro rich workflow Java clients to embedded workflow windows inside the Slicer.&amp;lt;br&amp;gt;&lt;br /&gt;
The embedded workflow management clients are to be implemented with QT/PyQT toolkits&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
INTEGRATION WITH XNAT:&amp;lt;br&amp;gt;&lt;br /&gt;
* Automated DICOM series upload with triggering DICOM headers parsing at XNat site (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress. &lt;br /&gt;
- Results upload to XNat (Completed) &amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat based on user's input (Project + Subject + PET or CT session / scan) (Completed)&amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat - perfomance boosting solution for downloads found , web services services are created, relinking for the client side in progress &amp;lt;br&amp;gt;&lt;br /&gt;
- Xnat querying for subjects and automated subject addition into the workflow (In Progress) &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-segmentation module added for auto correction of segmentation results. Particularly - relabeling CSF voxels segmented as Air inside the intracranial cavity. This was requested by end-users after processing images with zero-signals in CSF voxels &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting automated dual-echo DICOM images conversion and split into two NRRD volumes&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT / EM Segmentation pipeline:&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting memory allocation issues for scull-stripping module SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
COPD Project:&amp;lt;br&amp;gt;&lt;br /&gt;
* Benchmark test for accelerated DICOM downloads from XNat (remoote XNat Central server): we can handle at least 6 cases (4 CT scans in each) per hour, which is compatible with current workload quotes on SPL cluster processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* December 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Deployed Version 1. &amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Test project chosen as a closest match to registration scenario: Pediatric MS Cases from MGH - requires periodic image preview for different &lt;br /&gt;
modalities taken from vaious time points. Label maps for VOIs resampling is also required.&lt;br /&gt;
&lt;br /&gt;
* November 26, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user. Version 1 is complete&amp;lt;br&amp;gt;&lt;br /&gt;
* Started working on integration with XNat&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on input data organizing modules&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 19, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user (70% done)&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Universal Registration Workflow for Longitudinal Studies - design specs in progress&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 12, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Minor tuning to EM Segmentation template as of users' feedback&lt;br /&gt;
* Users started using the workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed input data conversion from Genesis to Slicer native or NIFTI format. Our help may be needed in input data organizing.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Tuned application according to co-laborators (PNL) needs&amp;lt;br&amp;gt;&lt;br /&gt;
* The webservices and BPEL workflow application are tested ready to accept computation requests from PNL case tracking system &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Discussed Universal Registration Workflow for Longitudinal Studies&lt;br /&gt;
* Started the thread about possible cooperation with Children hospital's image processing pipelines and integration with Xnat &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 5, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Webservices and workflow pilot project created and deployed on Psychiatry Neuroimaging Laboratory subnet &amp;lt;br&amp;gt;&lt;br /&gt;
* The V.1.0 deployment is scheduled for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 29, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Most of functionality is completed. Some volume statistics post processing is pending&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL EM SEGMENTATION Pipeline: &amp;lt;br&amp;gt;&lt;br /&gt;
* The SPECTRE scull stripping module. Started integration into EMS workflow. Made some test runs from Slicer GUI&amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Identified as a candidate for Workflow Application&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 22, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* All back-end functionality are implemented&amp;lt;br&amp;gt;&lt;br /&gt;
* EM Segmentation scene usability is confirmed by end-user&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for next week: add Label Statistics computation for CSF/Brain/ICC &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 15, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* The latest (October) builds of Slicer 3.6.2 produced acceptable results. This was verified by the target users. The EM Segmentation will be performed on Slicer 3.6.2 or later&amp;lt;br&amp;gt;&lt;br /&gt;
* The new Web services had been created and added to the pipeline as optional processing steps: Biasfield correction (implement novel N2ITKBiasFieldCorrection module) and Volume's scalar datatype casting (as workaround for Biasfield correction module not preserving image scalar datatype - the bug is filed) &amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed the Front-End GUI design with target users. The design pattern is taken from the PETCT project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 8, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-deployment support. Tuned CT registration as of user's feedback.&lt;br /&gt;
* Adapting to the Single Slicer build: Slicer 3.6.2. Found label duplicates in the label lookup table - will ask user if it's tolerable. Waiting for the Slicer 3.6.2 build that contains all required modules. Rolling back label tag appending code for SUVs - the latest Slicer build appends the tags.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Resumed development. The priorities are set for usage of Slicer 3.6.2 - subject for EM Segmentation scene tuning. Continued coding for Scene creation for Slicer 2.8 - as a backup option for ongoing research project.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 1, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized V1.0 release based on end-user feedback: updates relate mostly to error proofing and SUV values representation&lt;br /&gt;
* Post-deployment support. Users pre-processed first set of patients &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* September 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* System deployed and tested at End Users' site.&amp;lt;br&amp;gt;Users are trained to perform all tasks required by the workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
* Got positive feedback with suggestions on Slicer Scenes' layouts improvement and PET scans' SUV (standard uptake values) results display&lt;br /&gt;
* Two distribution packages are assembled: Lunix and MAC OS versions. The difference in two packages is in specific Slicer3.6/3.7 builds - subject to Slicer Linux builds debugging.&amp;lt;br&amp;gt; As a workaround for Linux deployment - multiple Slicer builds are used to perform various tasks (registration, opening editing scenes in Slicer, SUV computing)&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for coming week - finalize V1.0 release based on end-user feedback&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Embedded SUV computations into the workflow (as system calls - will be translated into web service later)&amp;lt;br&amp;gt;&lt;br /&gt;
* Pre-release demo for end users.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Create and debug EM Segmenter scenes template for Slicer 3.6 and 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* September 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation - workflow pipeline and deployment verified&amp;lt;br&amp;gt;&lt;br /&gt;
* Tested EM Segmentation scenes within Slicer 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
* Started migration of EM Segmentation to Slicer 3.6. Discovered issues had been reported to EM Segmenter module designers &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* August 29 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation completed. Preprocessing Pipleine completed 80% (subject for input registration parameters tuning) &amp;lt;br&amp;gt;&lt;br /&gt;
* Most webservices (for registration and resampling steps) had been taken and re-used from PET/CT ROI/Longitudinal Study - showing the advantage of service-oriented software design and deployment.&lt;br /&gt;
* Continued on distribution and deployment of the service/workflow applications: on PET/CT and AGING STUDY projects.&lt;br /&gt;
&lt;br /&gt;
PEDIATRIC Multiple Sclerosis Cohort. Support of multi-center distributed processing project&amp;lt;br&amp;gt;&lt;br /&gt;
* Introduced Slicer 3.6 for the MS Lesion Assessment step performed at Mayo Clinic. Images are being transferred from image repository at BWH and automatically opened and arranged within Slicer GUI for reading.  This was replacement of Client GUI using MIPAV that stopped working on new computers at Mayo Clinic.&lt;br /&gt;
The images are being loaded via generated MRML Scenes same way as in PET/CT and AGING STUDY projects &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* August 22 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Preprocessing pipeline merge with SUV computations &amp;lt;br&amp;gt;&lt;br /&gt;
- QA for SUVs computation was performed by Wendy Plesniak for images with known uptake values. &amp;lt;br&amp;gt;&lt;br /&gt;
- Discovered that image cropping step (not related to automated registration pipeline and SUVs computing) smoothes the images by doing interpolation when used with default settings. Got suggestions from Steve Piper using Nearest-Neighbor interpolation (&amp;quot;no interpolation&amp;quot;) for a time being&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
- This is the new project candidate. Requested for the images with failed manual segmentation and/or segmentation with FreeSurfer. The EM Segmentation run showed most acceptable results on one of the problem images back in February &amp;lt;br&amp;gt;&lt;br /&gt;
- The workflow will be developed and deployed similar to PET/CT ROI Longitudinal study approach - all preprocessing steps will be done with Slicer modules, all runs will be performed on local end-user machines.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
 &lt;br /&gt;
&lt;br /&gt;
* August 15 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- First 5 cases with 3-4 time points preprocessed for SUVs computation&lt;br /&gt;
&lt;br /&gt;
* August 8 2010&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Testing of installation and operation at users' site (Performed by Wendy Plesniak)&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* July 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Delivered beta version of registration pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
- Prepared installation and user manuals &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* June 11, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Registration modules completed &amp;lt;br&amp;gt;&lt;br /&gt;
- Irregular cases registration problem solved (when whole body and brain only scans are mixed for a timepoint)&amp;lt;br&amp;gt;&lt;br /&gt;
- Live demo of case setup and registration workflow for end users. Real case with 4 timepoints used&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Coming week plans&amp;lt;br&amp;gt;&lt;br /&gt;
- Adjust workflow based on end users' feedback&amp;lt;br&amp;gt;&lt;br /&gt;
- Integration with SUVs computing for PET scans&amp;lt;br&amp;gt;&lt;br /&gt;
- GUI for workflows dispatching and data organizing&amp;lt;br&amp;gt;&lt;br /&gt;
- (TBD) Integration with 4D time series analysis Slicer module&amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
* May 28, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- Migration to the latest Slicer 3.6 release candidate &amp;lt;br&amp;gt;&lt;br /&gt;
- Added webservice for new registration module: BRAINSFit &amp;lt;br&amp;gt;&lt;br /&gt;
- Test runs for new patients with 4 timepoints' scans &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Plans for next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI &amp;lt;br&amp;gt;&lt;br /&gt;
- processing workflow demo for end user &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 21, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Pilot version of portable web services and automated workflow tested: &amp;lt;br&amp;gt;&lt;br /&gt;
Linux: workflow and visual review passed&amp;lt;br&amp;gt;&lt;br /&gt;
Stress test for 25 timepoints passed &amp;lt;br&amp;gt;&lt;br /&gt;
MAC OS: workflow passed, visual review failing when PET/CT images are loaded into GUI simultaneously (bug report submitted)&amp;lt;br&amp;gt;&lt;br /&gt;
Windows: need to adapt command line modules and workflow management system to sygwin environment&amp;lt;br&amp;gt;&lt;br /&gt;
Plans for next week: integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI&lt;br /&gt;
&lt;br /&gt;
* May 7, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Selected registration and resampling modules with more precise and stable outputs. &amp;lt;br&amp;gt;&lt;br /&gt;
Started building portable web services and automated workflow &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 30, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- manual walk through the processing steps: ROI cropping, registration/resampling, PET pharmaceutical DICOM data retention. &amp;lt;br&amp;gt;&lt;br /&gt;
- testing workflow and web services packages distribution to end-users' machines&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* April 23, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : testing various registration and re-sampling algorithms (work in progress)&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation: as of collaborators' request, run existing EM Segmentation workflow for older low resolution pseudo-T1 images. The EM Segmentation works for those images with manual sampling. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 16, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
  Social Cognition Study: started Cortical Thickness Measurement module build (bases on NA-MIC ARCTIC pipeline) &amp;lt;br&amp;gt;&lt;br /&gt;
  PET/CT ROI/Longitudinal Study Registration : Design specs, PET-to-CT images registration tests on training data. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 9, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. GUI update based on end-user experience.&amp;lt;br&amp;gt;&lt;br /&gt;
User request: automated label maps' volumes calculation (Currently possible from Slicer3 GUI)&amp;lt;br&amp;gt; &lt;br /&gt;
PET/CT ROI Project. Initial design specs discussion with end-users and co-developers&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure&lt;br /&gt;
Verification of segmentation workflow GUI: from registering new case to reviewing results&amp;lt;br&amp;gt;&lt;br /&gt;
Cross study test of segmentation workflow: MGH/MS Center data - success,  HIV Project data - some EM Segmentation scene tuning is needed &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*&lt;br /&gt;
* April 2, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. Segmentation workflow completed&amp;lt;br&amp;gt;&lt;br /&gt;
* Coming Week plans:&amp;lt;br&amp;gt;&lt;br /&gt;
- Document Segmentation Workflow. Follow up with end users &amp;lt;br&amp;gt;&lt;br /&gt;
- Start with Cortical Thickness and ROI-in-longitudinal studies workflows&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* March 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All essential processing and workflow interaction clients are ready.&amp;lt;br&amp;gt;&lt;br /&gt;
- Completed segmentation for 10 out of 50 patients. The remaining cases will be finalized upon manual lesion segmentation and QC verification of WM/GM/CSF and Deep GM segmentation's. &amp;lt;br&amp;gt;&lt;br /&gt;
- TODO next week: refine QC GUI and data tracking / progress monitoring schema. &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&amp;lt;br&amp;gt;&lt;br /&gt;
- New Slicer3 web services added: re-slicing with reference image volume, casting image scalar type &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
* March 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Segmentation maps Merging Services for GM/WM/CSF (Slicer EM Segemnter), Lesion (Slicer, Manual), and Deep GM (FreeSurfer)  &amp;lt;br&amp;gt;&lt;br /&gt;
- Deep GM segmentation pipeline adopted as optional service for Social Cognition Study (22 out of 50 cases processed) &amp;lt;br&amp;gt;&lt;br /&gt;
- (In progress) GUI client for Launching Segmentation results merging with optional Deep GM segmentation with FreeSurfer &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- Complete GUI Client for Segmentation result merging &amp;lt;br&amp;gt;&lt;br /&gt;
- Progress Monitoring services for entire Study processing: EM Segmenter Preprocessing, EM Segmentation, Lesion Segmentation (including human activities assignments), Deep GM segmentation, and results consolidation. &amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* March 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All 50 cases went through &amp;quot;basic&amp;quot; One-channel EM segmentation (GM/WM/CSF) &amp;lt;br&amp;gt;&lt;br /&gt;
- Basic pipeline start-up command line client created: user has two options - request brainmask extraction or provide with previously extracted brainmask for a given subject &amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison of GM/WN/CSF performed for Slicer EM Segmenter and FreeSurfer recon-all (used with default settings). &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmenter provides more accurate output &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmentation pipeline runs faster (40 minutes vs 12 hrs when no brainmask extraction requested) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO:&amp;lt;br&amp;gt;&lt;br /&gt;
- merging modules for automatic 1-channel EM segmentation and manual lesion segmentation &amp;lt;br&amp;gt;&lt;br /&gt;
- Emerge Cortical Thickness pipeline project: use NAC ARCTIC processing steps and modules &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Selected stable EM Segmentation scenario: White Matter, Gray Matter, and Cerebrospinal Fluid &amp;lt;br&amp;gt;&lt;br /&gt;
- First 16 cases are segmented for selected scenario. Nine more cases are preprocessed for EM Segmentation.&amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison to segmentation with FreeSurfer showed better accuracy for Slicer2 EMSegmenter &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure &amp;lt;br&amp;gt;&lt;br /&gt;
- Three prerpcocessed cases failed during volume ICC masking with in-house build utility. Evaluated switching to Slicer3 Mask and island removing modules.&amp;lt;br&amp;gt;&lt;br /&gt;
- Initial design specs discussion for cortical thickness measurement pipeline. ARCTIC pipeline selected. ARCTIC preprocessing steps signifficantly overlap with EM Segmentation preprocessing workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
  &lt;br /&gt;
* February 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: &amp;lt;br&amp;gt;&lt;br /&gt;
A) parameters tuning for EM Segmenter itself (work with EM Segmenter developer), template scenes creation &amp;lt;br&amp;gt;&lt;br /&gt;
B) update preprocessing pipeline - deep gray matter atlases included &amp;lt;br&amp;gt;&lt;br /&gt;
C) test and debug preprocesing pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
D) identified missing modules: atlas autocalibration for EM Segmentation scene, Island removal for ICC mask&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- Review currently deployed modules. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: reviewed firts seven subjects' outputs, added volume orientation module into pipeline (prevents ICBM atlas linear registration failures)&amp;lt;br&amp;gt;&lt;br /&gt;
- Fused ICC(brainmask) extraction module with EM Segmenter preprocessing. Three scenarious implemented: start with pre-extracted ICC mask (longitudinal studies case), run with ICC ectration, run with ICC extraction AND ICC correction before ICBM atlas preporcessing. &amp;lt;br&amp;gt;&lt;br /&gt;
- Completion of Human activities GUI (QC, ICC Correction) planned for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: Volume Orientation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: automated preprocessing pipeline for Slicer2 EM Segmenter test version deployed. Seven cases pre-processed.&lt;br /&gt;
- PET Quantitative measurements: Preliminary design specs discussion.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: BSplineRegistration (for non-linear registration), ResampleVolume2 (for atlases resampling based on image atlase templates registration). Local and Network runs are implemented, Cluster/GridWizard implementation pending.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Slicer EM Segmenter module: preprocessing design for Slicer2 EM Segmenter&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Adapting for Slicer2 EM Segmenter (mostly from pipelines and services for previous projects)&lt;br /&gt;
  -- Integration with FreeSurfer modules for bisafield correction, brainmask extraction, and linear registration of ICBM atlases&lt;br /&gt;
  -- Preprocessing updates for non-linear registration of ICBM atlases with Slicer2 (image re-orientation service designed)&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 29, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- EM Segmentaton pipeline: preprocessing results are being transferred to XNat (anonymized data, Central XNat) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Slicer EM Segmenter module: discussed agenda and scheduled a work meeting for Social Cognition Study image segmentation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Testing stage, 95% completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- SPL XNat server: verified data exchange via RESTfull web services.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 22, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Follow up with White Matter Lesion Segmenter and Scull Stripping Modules developers: Work in Progress&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Work in Progress, 60%+ completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Discussed SPINE image repository migration to XNat&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 15, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. &lt;br /&gt;
- Social Cognition Study: &lt;br /&gt;
Work-in-progress on intermediate (reconstruction) and results (resources) data storage at XNat.&lt;br /&gt;
&amp;lt;br&amp;gt;Reviewing and preparation more cases for EM Segmentor (Slicer 3.5) tuning.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* NA-MIC Project Week&lt;br /&gt;
Selecting candidate Slicer modules for other than Lesion EM Segmentation topics of Social Cognition study: Withe Matter Lesion Segmenter (UNC), Scull Stripping utility from UIOWA.&lt;br /&gt;
Reviewing issues of currently used Scull Stripping Slicer Extension and Slicer 3.5 EM Segmenter.&lt;br /&gt;
&amp;lt;br&amp;gt;XNat Data organizing training&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 1, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Preparation of Demo for NA-MIC work week: &lt;br /&gt;
- COPD Study. Added Remote pipepline start interface (represents real world scenario where Xnat repository, Processing modules and User are at different sites)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
- EM Segmentation. Added human activities steps to the workflow: ICC (brainmask) correction and EM Segmantation scena load per se.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 25, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Pilot workflow pipeline for EM Segmentation (all steps except user-activity step: ICC correction assignment and tracking)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 18, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Build and tested web services for EM Segmentation image preprocessing: DICOM-to-NRRD conversion, registration, skull stripping, image masking.&lt;br /&gt;
Started building workflow pipeline (subject to finish first version next week)&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Started Collecting Library of Slicer Build number vs. functional modules and extensions.&lt;br /&gt;
Plan for NAMIC project week: scheduled meetings for XNat data customization, Skull-stripping modules tuning, identified Social Cognition study cases that fail EM Segmentation processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 11, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Updating and verification of EM Segmentation Scenario&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Projects:ARRA:SlicerWF:UseCaseScenarios#Usecase_MS_lesion_Assessment&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Familiarizing with Slicer3.4/5 Modules required for implementation of EM Segmentation Scenario. Participation in debugging and/or usage tuning of Dicom Conversion, Registration, Skull Stripping, Masking, and Image Casting modules. &lt;br /&gt;
&lt;br /&gt;
* December 4, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Slicer3.4's EM Segmentation and Visual QC as part of image processing pipeline for Social Cognition Study for MS Patients.&lt;br /&gt;
Project emerged. EM Segmentation template creation debugged.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
Emphysema Measurements (COPD Study) - workflow stability and scalability test.&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 27, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Emphysema Measurements (COPD Study).&lt;br /&gt;
Added compensation for long running calculations and time-outs to the main computing pipeline.&lt;br /&gt;
Visual QC (work in progress)&lt;br /&gt;
** Infrastructure&lt;br /&gt;
XNat data structure customization, metadata storage, results consolidation: new feature request list creation (work in progress)&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 13, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
*** Pilot system for whole processing cycle for Emphysema Measurements (COPD Study) including the following:&lt;br /&gt;
Web query for CT session file list download&lt;br /&gt;
Pilot user interface for submitting the file list and starting processing pipeline&lt;br /&gt;
Notification about processing steps and failures&lt;br /&gt;
Upload results to XNat repository (at this stage results are uploaded into same folder where original scans are(*))&lt;br /&gt;
*** Immediate Plans&lt;br /&gt;
Complete Visual QC module&lt;br /&gt;
Design and implement meta-data transfer to XNat (including processing details and MRML files for loading images into the 3D Slicer)&lt;br /&gt;
&lt;br /&gt;
(*)Customization of results storage&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 6, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Tuned and debugged multiple subjects processing for: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat.&lt;br /&gt;
***Started working on quality control embedding into the above scenario. Plan to complete and video-record demo next week.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***Published general Product Integration scenario flow chart to collaborators' community. Discussion is open and in progress&lt;br /&gt;
&lt;br /&gt;
* October 30, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Piloted and tested the sequence: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat(1).&lt;br /&gt;
***Performance test of overall cycle: data transfer from remote serve is a bottleneck as expected&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data browsing features reviewed.&lt;br /&gt;
(1) Not automated yet&lt;br /&gt;
* October 23, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Defined COPD processing scenario with interoperability between Xnat, 3D Slicer Command Modules, Workflow, and Gridwizard Enterprise.&lt;br /&gt;
***Pilot version of Emphysema Measurements workflow pipeline deployed.&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data transfer features reviewed. Use account at XNat Central during learning curve.&lt;br /&gt;
***Feasibility test of 3D Slicer fiducials module for ROI highlights during QC and manual image processing activities. &lt;br /&gt;
* October 16, 2009&lt;br /&gt;
**Lung CT Scans Processing. Pilot project emerged. GenerateEmphysemaMeasurements module deployed as a webservice that submits jobs to computational cluster.&lt;br /&gt;
**EM Segmentation. Familiarized with GUI steps. Started working on automation steps outlining&lt;br /&gt;
**3D Slicer and XNat interaction. Got an overview from Wendy Plesniak.&lt;br /&gt;
* October 1 - 7, 2009&lt;br /&gt;
**Selected two first priority Projects: EM Segmentation of brain MRI images; Lung CT Scans Processing (COPD Study)&lt;br /&gt;
**Got initial outline of user requirements and design specs&lt;/div&gt;</summary>
		<author><name>Azaitsev</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=File:SlicerWF_EMSegmentProjectsReview.zip&amp;diff=66937</id>
		<title>File:SlicerWF EMSegmentProjectsReview.zip</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=File:SlicerWF_EMSegmentProjectsReview.zip&amp;diff=66937"/>
		<updated>2011-04-29T19:41:10Z</updated>

		<summary type="html">&lt;p&gt;Azaitsev: uploaded a new version of &amp;quot;File:SlicerWF EMSegmentProjectsReview.zip&amp;quot;:&amp;amp;#32;Added Aging Study data, added participant's names&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Projects' review that include EM Segmentation as a part of workflow process: Image parameters and Screenshots are included&lt;/div&gt;</summary>
		<author><name>Azaitsev</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=66928</id>
		<title>Projects:ARRA:SlicerWF</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=66928"/>
		<updated>2011-04-29T16:57:27Z</updated>

		<summary type="html">&lt;p&gt;Azaitsev: /* Presentations */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Projects:ARRASuplements|Back to Slicer ARRA home page]]&lt;br /&gt;
= Aim =&lt;br /&gt;
Supplement 3D Slicer and Extensible Neuroimaging Archive Toolkit (XNAT) with workflow management system. Provide integration and interoperability between 3D Slicer, XNAT Services and 3-rd party image processing applications and high performance computing systems. Implement it as within currently developed Structural Planning and Implementation in Neurological Exploration (SPINE) System.&lt;br /&gt;
&lt;br /&gt;
= SPINE Project Documentation =&lt;br /&gt;
[http://cni.bwh.harvard.edu/projects/spine/index.html SPINE Docs]&lt;br /&gt;
&lt;br /&gt;
= Presentations =&lt;br /&gt;
* Segmentation Workflow. PECS University Social Cognition Study.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:SlicerWF_NAC_PECS_Workflow.pdf]]&lt;br /&gt;
* EAB10_ARRA Annual Progress Report Slides.&amp;lt;br&amp;gt;&lt;br /&gt;
[[media:EAB10_ARRA_WF_2011_Zaitsev.ppt | Service Oriented Solutions for 3D Slicer. EAB10_ARRA_WF_2011. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:EAB10_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:NAMIC_ARRA_WF_2011_Zaitsev.ppt  | NAMIC Annual Report 04/2010-03/2011. NAMIC_ARRA_WF_2011_Zaitsev. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:NAMIC_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:Slicer_WF_Slicer4CARMAWorkflow.ppt  | CARMA Workflow. Cardiac Ablation Followup. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:Slicer_WF_Slicer4CARMAWorkflow.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Segmentation Workflows: Screenshots, scans' and study description : [[File:SlicerWF_EMSegmentProjectsReview.zip]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
= All Hands Meeting Pages =&lt;br /&gt;
* Salt Lake City 2011 Winter [http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA SLC_2011_WorkFlow]&lt;br /&gt;
* MIT 2010 Summer [http://wiki.na-mic.org/Wiki/index.php/Summer_project_week_2010_Workflows_SOA MIT_2010_WorkFlow]&lt;br /&gt;
&lt;br /&gt;
= Research Plan =&lt;br /&gt;
*Create a stand-alone SPINE desktop agent with fully functional data exchange and communication mechanisms towards 3D Slicer and XNAT.&lt;br /&gt;
*Develop Service Oriented Architecture (SOA) SPINE System that will include 3D Slicer image processing modules deployed as web services as well as a workflow management system to orchestrate interaction between 3D Slicer, XNAT, and 3-rd party tools.&lt;br /&gt;
*Implement two-way control and communications between 3D Slicer and SPINE modules.&lt;br /&gt;
*Adapt SPINE System for cluster and grid computing scenarios.&lt;br /&gt;
*Provide with workflow and 3D Slicer web service wrappers editing tools.&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:UseCaseScenarios| Use Case scenarios]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PETCTWorkflow| PETCTWorkflow]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:AgingStudySegmentation| AgingStudySegmentation]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:TwoTensorTractography| TwoTensorTractography]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:LongitudinalMultimodalityRegistrationSuite| LongitudinalMultimodalityRegistrationSuite]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:MigrationJavaClients2QT| MigrationJavaClients2QT]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PediatricMSSegmentation| PediatricMSSegmentation]]&lt;br /&gt;
*[[DBP3:Utah:RegSegPipeline| MRI-based study and treatment of atrial fibrillation]]&lt;br /&gt;
&lt;br /&gt;
= Application Server / Workflow Engine Downloads =&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:WFEngineDownloads| Download Links]]&lt;br /&gt;
&lt;br /&gt;
=Key Personnel=&lt;br /&gt;
* Charles Gutmann, MD., 4%,  9-17-2009 through 9-16-2011&lt;br /&gt;
* Alexander Zaitsev, Ph.D., 75%, 9-17-2009 through 9-16-2011 &lt;br /&gt;
&lt;br /&gt;
=Annual Progress Statements =&lt;br /&gt;
'''2010-11''' &amp;lt;br&amp;gt;&lt;br /&gt;
The  April 2011 – March 2011 period was devoted on developing portable workflow solutions that can be deployed on end-users' workstations or notebooks with minimal or no system administration activities. This is in contrast to the server-side deployment. The following scenarios had been deployed and used for actual projects that require the following types of workflows: PET/CT registration and computation of biomarker driven brain physiological activities, Brain MRI Images segmentation,  MRI and MRI Angiography images pre-processing for cardiac ablation outcome estimation. Some  workflows (like EM Segmentation) had been utilizing various scenarios, some research projects  (like evaluation of chemotherapy outcome) require two types of workflows to assess physiological and structural changes. Starting from the 4th Quarter of 2011, the migration project had been emerged in order to embed Workflow GUIs into newly developed Slicer4 Suite. The existing rich client Java GUI applications are being re-written as C++/QT Sliceletts units, new modules (such as cardiac ablation project support) are had been written from scratch. The latter are being deployed from the Slicer4 GUI and act at a liaison between Slicer4 and Application Server containing  workflow and Slicer modules deployed as services. The feedback from the end users indicates that Workflow approach for the complex processing improves productivity, aids to the processing standardization and contributes to the overall experience using 3D Slicer&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
=Quarterly Progress=&lt;br /&gt;
&lt;br /&gt;
* NAMIC Annual Progress Slides (April 2010 - March 2011):&lt;br /&gt;
&lt;br /&gt;
* '''1st Qtr, 2011''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study: Second release is under testing by end-users. &lt;br /&gt;
*** Added MRI registration to aid ROI drawing on PET scans&lt;br /&gt;
*** Improved SUV results reporting and added flexibility to update ROI lookup table&lt;br /&gt;
*** Automated EM Segmentation of MRI images for computing SUVs for white matter, CSF, and whole brain (80% completion)&lt;br /&gt;
*** Integration with SPECTRE scull stripping module (70% completion) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** EM Segmentation: Automated WF Pipelines are created &amp;lt;br&amp;gt;&lt;br /&gt;
*** Flexible atlas selection (Pediatric, etc) feature added&lt;br /&gt;
*** Workflows implemented for EM Segmenter 3.6.2 and 3.6.3 (1st Qtr 2011 release)&lt;br /&gt;
&lt;br /&gt;
** Cardiac ablation results follow-up: Workflow for registration and ROI selection of cardiac MRI and MR Angiography &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Wrokflow and Web Services for prospective DTI tractography modules (currently written as Matlab modules at PNL) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Web Services for SPECTRE Scull stripping module&lt;br /&gt;
*** Accuracy and performance tuning&lt;br /&gt;
*** 50% completion&lt;br /&gt;
&lt;br /&gt;
** Migration Front End GUI to Slicer4/QT:&lt;br /&gt;
*** EM Segmentation&lt;br /&gt;
*** Cardiac Ablation Study&lt;br /&gt;
&lt;br /&gt;
** DICOM Uploader and Desktop Browser for XNat Image repository (alpha version - tested for MGH MS Center studies, proposed to use with MI2B2 Clients and Services)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''4th Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study and EM Segmentation for Aging Study are deployed at end-user sites and actively used for research. &lt;br /&gt;
** Adopted EM Segmentation preprocessing pipeline for HIV Study: high resolution SPGR images, integration with FreeSurfer brainmask extraction outputs; integration of Slicer SPECTRE module for brainmask extraction is in progress.&lt;br /&gt;
** The following post-release upgrades had been implemented based on end-user feedback: Application Server basic controls are performed from Rich Client GUI as alternative to traditional IT administration activities. The controls are implemented on point-and-click bases and include web services and workflow application deployment and upgrades, application server start and stop as well as warning end user when the server is not accepting request.&lt;br /&gt;
** Added DICOM downloads and results uploads of PET/CT pipelines from and to XNat Repository&lt;br /&gt;
** Created Services and Workflow for Matlab Prototypes modules. Case Study: tractography for DTI images&lt;br /&gt;
** Extended XNAT integration services:&lt;br /&gt;
*** Browsing capabilities of XNat data repository from the Workflow Applications&lt;br /&gt;
*** Improved DICOM upload and download performance&lt;br /&gt;
*** Added Metadata organizing services for uploaded DICOM images: header data extraction, image snapshots creation. &lt;br /&gt;
** Started project for Rich Client GUI migration from Java desktop application to build into SLicer4 QT modules. This affects mostly front-end GUI and has the following approaches: distribution with the Slicer4, end-user will select desired workflow application from Slicer4 menu while QT-written modules provide with the same functionality as Java Rich Clients. Case Study for the Migration process: registration suite for longitudinal studies that include multi-modality images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* '''3d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Concentrated on building downloadable workflow applications that could run both in desktop (new) and server environment, and that require minimum IT administrative resources. The desktop deployment is in compliance with Slicer3 general deployment concept.&lt;br /&gt;
*** The following use case scenario had been chosen: PET/CT image processing for longitudinal studies, EM Segmentation for longitudinal Aging Study.&lt;br /&gt;
** Released workflow application for PET/CT image processing for longitudinal studies. Provided end users with training and documentation.&lt;br /&gt;
*** The PET/CT processing workflow was designed to be a general application used whenever both structural patterns and metabolic activities are within the research scope. &lt;br /&gt;
*** The desktop version is tuned to use minimal computer resources, so the automates processing instances do not interfere with human activities. Automated activities may include, for example, registration and PET scan's standard uptake values computing, and manual human activities may include image cropping, quality control, and labeling voxels of interest.&lt;br /&gt;
** Core services and EM Segmentation preprocessing workflow was build for retrospective Aging Study. Tuned the Slicer3 webservices for processing low grade images acquired in mid 90s. Entire workflow is implemented with Slicer3 only modules and can be deployed locally and on the servers. Usage of Service Oriented Architecture (SOA) as a core technological approach allowed reusing most of the web services that had been build for PET/CT project. &lt;br /&gt;
** Continued embedding Slicer3 application and modules into previously released processing pipelines: replaced MIPAV with Slicer3 GUI for lesion assessment step in the multi-center Pediatric MS Cohort image processing &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''2d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Completed Social Cognition Workflow Implementation. This includes EM Segmetnation pre- and post-processing pipelines, data tracking, and integration with 3d party image processing utilities, as well as processing results acquired manually with Slicer GUI.  &lt;br /&gt;
** Multi-modality image registration and ROI selection/alignment workflow for longitudinal studies. &lt;br /&gt;
*** Use case: PET/CT image processing for longitudinal studies. &lt;br /&gt;
*** Build portable library of Slicer modules as web services and workflow that are deployed and run on a end-users' worksatations without utilization of SPL and other servers. The web services include novel Slicer3 modules, such as BRAINSFit and BRAINSResamle &lt;br /&gt;
*** Started working with Slicer3 developers on Slicer 3.8 GUI wizard to communicate with workflow instances.&lt;br /&gt;
** Participated at NA-MIC Summer 2010 Project Week: [[Summer_project_week_2010_Workflows_SOA]]&lt;br /&gt;
&lt;br /&gt;
=Progress=&lt;br /&gt;
* April 22, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Beta release ready. Demo Location: http://cni29.bwh.harvard.edu/SlicerWFDemo/index.php&lt;br /&gt;
* TODO: Tutorial. Original inputs copy/renaming&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 15, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Adding App server auto-config features&lt;br /&gt;
* Finalizing the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 08, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Second release beta build tested on cosutmer side &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review registration quality (with Dr. Meier). Angiography images' Resampling tuned. &lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 01, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the second release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
XNat Integration&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* (Java) GUI for Project Browsing and DICOM Series Upload. Post-upload DICOM processing tested and debugged&amp;lt;br&amp;gt;&lt;br /&gt;
* Ready for integration with mi2b2 client.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Migrated to Latest Slicer 3.6.3 stable release: only the Input scene had to be updated, the API remained the same&lt;br /&gt;
* Tested EM Segmenter with CMTK4Slicer extension - processing takes to much time on Linux_64bit machine, rolled back to BRAINSFit registration. When used on Mac OS X build, the Slicer could not start (bug report 1126).&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SPECTRE Scull Stripping:&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Testes for various use cases: the module is extremely sensitive to T1 MRI quality (does not work for most MRIs from PET/CT project&lt;br /&gt;
* TODO next week: check for FLAIR images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Slicer4 QT GUI and Cropping activity in progress.&amp;lt;br&amp;gt;&lt;br /&gt;
* Tried direct MRA to MRA registration option: resampling with LMRI registration transforms works better.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Extra VOI labels revised&lt;br /&gt;
* Debugging of SUV results' renormalization step&lt;br /&gt;
* TODO: ICC extraction / whole brain total uptake computing; EM Segmentation for R_WM, L_WM SUV computing and BPH estimation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SCULL STRIPPING/SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Installed and tested CLI option on Linux_64bit platform&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Workflow interruption before BSPline registraton: BPEL Module completed. Slicer4 QT GUI and Cropping activity in prorgess.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Implemented and Tested with end-users proposed changes: denormalization of SUV results, adding more VOI labels, added FLAIR MRI in addition to T1s for VOI drawing&lt;br /&gt;
* Tested manual ICC extraction using PET scans: works satisfactory with island removal and cropping followed by threshold level labeling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4&lt;br /&gt;
* Change proposed: interrupt workflow after affine registration and have user crop the VOI. This is to prevent excessive deformations for BSpline registration and resampling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4. User has option to choose the atlas that fits better for the given subject (NOTE: hardcoding must be rewritten for atlas linking)&lt;br /&gt;
* PETCT test - the problem is that T1s are low resolution and with contrast. Proposed using T1s without contrast&lt;br /&gt;
* PETCT change request: users wants to compute SUV for entire ICC. Had demo how to segment brainmask/ICC using PET scan. The derived brainmask label can be used for SUV computation.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - cmpleted&lt;br /&gt;
* Sample cases run - excessive deformation after BSpline registration hase&lt;br /&gt;
* Next week plan - pull tuning controls to front-end of pipeline API, start working of QT module for CARMA registration&lt;br /&gt;
* May consider other than BRAINSFit registration modules&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Design plan for change request: more VOI labels, add FLAIR in addition to T1 for VOI drawing, T1s segmentation&lt;br /&gt;
* Tested segmentation for sample cases - artifacts from poor quality MRIs lead to exclusion of parts of ICC from segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Completed troubleshooting of EMSegmenter module calling from Java (need TCL libs to be pulled from Slicer environment)&lt;br /&gt;
* Tested EMSegmenter autoruns for HIV and Pediatric MS patiens. Work as expected, subject to improvement of PED MS case segmentation by building better skull/neck/air atalses&lt;br /&gt;
* Suggested usage of two subsets of atalases: with and without neck. The Subject MRIs have to be cropped accordingly or best fit atlas has to be selected&lt;br /&gt;
* Made no-neck cropped atlas collection for default EMSegmenter scenario&lt;br /&gt;
* Tested with PET/CT study MRI cases - see above &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - in progress&lt;br /&gt;
* Next week goal - have back end processing ready&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Longitudinal Study&lt;br /&gt;
* Added MRI registration to the pipeline&lt;br /&gt;
* Troubleshooting of complex XML schema issues on Linux machines (some modules working on MAC do not work on Linux). As a workaround - did not include MRI convert and register part into base BPEL module. Used separate services (transparent for end-user)&lt;br /&gt;
* TODO next week for change request completion: explicit pixel type casting for MRI in BRAINSFit, VOI MRML scene update (currently MRI added on top of schema)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* February 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipeline for Pediatric MRI. Same scenario as for HIV Project, icbm pediatric atlases (Completed, verified)&lt;br /&gt;
* Collected NIH healthy brain development atlases: various age ranges from 4.5 to 18 yo. Converted to Slicer readable format &lt;br /&gt;
* Work on web services for the new automated EM Segmenter module (release Nov 10 - current). Verified task completion both for adult and pediatric images. Discussed tuning parameters for work load balance on workstations.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Started working on MRI registration to the reference CT scans. &lt;br /&gt;
* Design specs for optional White Matter segmentation for SUV computing.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* February 4, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipelines for Pediatric MRI (in progress)&lt;br /&gt;
* Adapting Pediatric T1 atlases for &amp;quot;Human Brain&amp;quot; build-in EM Segmentation wizard (in progress)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 28, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Verifying EM Segmenter module for latest builds and HIV/PED MS Studies (report pending)&lt;br /&gt;
* Work with SPECTRE module developers with pediatric MRI brainmask extraction&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* January 21, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Compiling plan for WF FrontEnd GUI migration to Slicer4/QT Widgets&lt;br /&gt;
* Preparing for annual progress report&lt;br /&gt;
&lt;br /&gt;
* January 14, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI: Integrated into the Slicer4 as Slicelet (or thin Client)&lt;br /&gt;
* Participation at AHM-2011, discussing integration of SPECTRE module and updated approach to EM-Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA&lt;br /&gt;
&lt;br /&gt;
* January 7, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* HIV project workflow delivered. Major additions relate to user convenience: &lt;br /&gt;
- Project-specific parameter settings, importing T1s and brainmasks from FreeSurfer outputs with conversion to NIFTI, resampling brainmask to original scans and automatied subject addition.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Follow up with end user: need to add MRI scans, if available, addition and registration to CT in order to ease VOI drawings.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
 &lt;br /&gt;
* December 31, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Follow-up with user Experience for AGING Study Segmentation (Positive feedback)&lt;br /&gt;
* Target date for HIV project delivery - next week&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Self-training for QT widget development&amp;lt;br&amp;gt;&lt;br /&gt;
* Outlined Workflow Rich Clients migration strategy from Java to QT/Slicer4:&amp;lt;br&amp;gt;&lt;br /&gt;
** Use Java Stubs (similar to SPECTRE integration) or file binding for envocation of workflow pipelines. (See SOAP remark below)&lt;br /&gt;
** Direct Web Servisec calls must be wrapped into REST protocol. The reason: NON-commerchial QT kit does not include SOAP protocol for web servises.&lt;br /&gt;
** The GUI will be implemented as page widget or QT dialog GUI forms called from within Slicer4.&lt;br /&gt;
** Communications between Slicer4 and WF GUI will be set via child-parent and signal-slot relations&lt;br /&gt;
* Worked on a Prototype for Basic EM Segmentation QT widget (70% complete). Will work on integrtion with SLicer4 during the AHM-2010&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
XNAT Integration&lt;br /&gt;
* Debugged XNAT RESTFul API usage for uplaoding DICOM series followed by header data extraction and image snapshots creation&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Added compensation for failed atlas registration (subject for old poor quality pseudo-T1 images): blank probability maps are created in case of failure.&lt;br /&gt;
* Data preparation module for FreeSurfer data import near completion. Expected time for deployment at end-users workstations - first week of January&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Discussed strategy for EM Segmentation pipeline solutions collection (K. Pohl, R. Kikinis)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* RE-using the same core workflow as for 1-channel EM Segmentation of AGING STUDY cases&lt;br /&gt;
* Added data input preparation module: ICC label mask preparation and skull-stripping based on FreeSurfer brainmask output volume.&lt;br /&gt;
* Two-channel EM segmentation pipeline (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE / GENERAL Development &amp;lt;br&amp;gt;&lt;br /&gt;
* Worked on plans for migrating fro rich workflow Java clients to embedded workflow windows inside the Slicer.&amp;lt;br&amp;gt;&lt;br /&gt;
The embedded workflow management clients are to be implemented with QT/PyQT toolkits&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
INTEGRATION WITH XNAT:&amp;lt;br&amp;gt;&lt;br /&gt;
* Automated DICOM series upload with triggering DICOM headers parsing at XNat site (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress. &lt;br /&gt;
- Results upload to XNat (Completed) &amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat based on user's input (Project + Subject + PET or CT session / scan) (Completed)&amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat - perfomance boosting solution for downloads found , web services services are created, relinking for the client side in progress &amp;lt;br&amp;gt;&lt;br /&gt;
- Xnat querying for subjects and automated subject addition into the workflow (In Progress) &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-segmentation module added for auto correction of segmentation results. Particularly - relabeling CSF voxels segmented as Air inside the intracranial cavity. This was requested by end-users after processing images with zero-signals in CSF voxels &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting automated dual-echo DICOM images conversion and split into two NRRD volumes&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT / EM Segmentation pipeline:&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting memory allocation issues for scull-stripping module SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
COPD Project:&amp;lt;br&amp;gt;&lt;br /&gt;
* Benchmark test for accelerated DICOM downloads from XNat (remoote XNat Central server): we can handle at least 6 cases (4 CT scans in each) per hour, which is compatible with current workload quotes on SPL cluster processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* December 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Deployed Version 1. &amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Test project chosen as a closest match to registration scenario: Pediatric MS Cases from MGH - requires periodic image preview for different &lt;br /&gt;
modalities taken from vaious time points. Label maps for VOIs resampling is also required.&lt;br /&gt;
&lt;br /&gt;
* November 26, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user. Version 1 is complete&amp;lt;br&amp;gt;&lt;br /&gt;
* Started working on integration with XNat&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on input data organizing modules&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 19, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user (70% done)&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Universal Registration Workflow for Longitudinal Studies - design specs in progress&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 12, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Minor tuning to EM Segmentation template as of users' feedback&lt;br /&gt;
* Users started using the workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed input data conversion from Genesis to Slicer native or NIFTI format. Our help may be needed in input data organizing.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Tuned application according to co-laborators (PNL) needs&amp;lt;br&amp;gt;&lt;br /&gt;
* The webservices and BPEL workflow application are tested ready to accept computation requests from PNL case tracking system &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Discussed Universal Registration Workflow for Longitudinal Studies&lt;br /&gt;
* Started the thread about possible cooperation with Children hospital's image processing pipelines and integration with Xnat &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 5, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Webservices and workflow pilot project created and deployed on Psychiatry Neuroimaging Laboratory subnet &amp;lt;br&amp;gt;&lt;br /&gt;
* The V.1.0 deployment is scheduled for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 29, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Most of functionality is completed. Some volume statistics post processing is pending&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL EM SEGMENTATION Pipeline: &amp;lt;br&amp;gt;&lt;br /&gt;
* The SPECTRE scull stripping module. Started integration into EMS workflow. Made some test runs from Slicer GUI&amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Identified as a candidate for Workflow Application&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 22, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* All back-end functionality are implemented&amp;lt;br&amp;gt;&lt;br /&gt;
* EM Segmentation scene usability is confirmed by end-user&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for next week: add Label Statistics computation for CSF/Brain/ICC &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 15, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* The latest (October) builds of Slicer 3.6.2 produced acceptable results. This was verified by the target users. The EM Segmentation will be performed on Slicer 3.6.2 or later&amp;lt;br&amp;gt;&lt;br /&gt;
* The new Web services had been created and added to the pipeline as optional processing steps: Biasfield correction (implement novel N2ITKBiasFieldCorrection module) and Volume's scalar datatype casting (as workaround for Biasfield correction module not preserving image scalar datatype - the bug is filed) &amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed the Front-End GUI design with target users. The design pattern is taken from the PETCT project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 8, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-deployment support. Tuned CT registration as of user's feedback.&lt;br /&gt;
* Adapting to the Single Slicer build: Slicer 3.6.2. Found label duplicates in the label lookup table - will ask user if it's tolerable. Waiting for the Slicer 3.6.2 build that contains all required modules. Rolling back label tag appending code for SUVs - the latest Slicer build appends the tags.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Resumed development. The priorities are set for usage of Slicer 3.6.2 - subject for EM Segmentation scene tuning. Continued coding for Scene creation for Slicer 2.8 - as a backup option for ongoing research project.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 1, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized V1.0 release based on end-user feedback: updates relate mostly to error proofing and SUV values representation&lt;br /&gt;
* Post-deployment support. Users pre-processed first set of patients &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* September 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* System deployed and tested at End Users' site.&amp;lt;br&amp;gt;Users are trained to perform all tasks required by the workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
* Got positive feedback with suggestions on Slicer Scenes' layouts improvement and PET scans' SUV (standard uptake values) results display&lt;br /&gt;
* Two distribution packages are assembled: Lunix and MAC OS versions. The difference in two packages is in specific Slicer3.6/3.7 builds - subject to Slicer Linux builds debugging.&amp;lt;br&amp;gt; As a workaround for Linux deployment - multiple Slicer builds are used to perform various tasks (registration, opening editing scenes in Slicer, SUV computing)&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for coming week - finalize V1.0 release based on end-user feedback&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Embedded SUV computations into the workflow (as system calls - will be translated into web service later)&amp;lt;br&amp;gt;&lt;br /&gt;
* Pre-release demo for end users.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Create and debug EM Segmenter scenes template for Slicer 3.6 and 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* September 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation - workflow pipeline and deployment verified&amp;lt;br&amp;gt;&lt;br /&gt;
* Tested EM Segmentation scenes within Slicer 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
* Started migration of EM Segmentation to Slicer 3.6. Discovered issues had been reported to EM Segmenter module designers &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* August 29 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation completed. Preprocessing Pipleine completed 80% (subject for input registration parameters tuning) &amp;lt;br&amp;gt;&lt;br /&gt;
* Most webservices (for registration and resampling steps) had been taken and re-used from PET/CT ROI/Longitudinal Study - showing the advantage of service-oriented software design and deployment.&lt;br /&gt;
* Continued on distribution and deployment of the service/workflow applications: on PET/CT and AGING STUDY projects.&lt;br /&gt;
&lt;br /&gt;
PEDIATRIC Multiple Sclerosis Cohort. Support of multi-center distributed processing project&amp;lt;br&amp;gt;&lt;br /&gt;
* Introduced Slicer 3.6 for the MS Lesion Assessment step performed at Mayo Clinic. Images are being transferred from image repository at BWH and automatically opened and arranged within Slicer GUI for reading.  This was replacement of Client GUI using MIPAV that stopped working on new computers at Mayo Clinic.&lt;br /&gt;
The images are being loaded via generated MRML Scenes same way as in PET/CT and AGING STUDY projects &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* August 22 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Preprocessing pipeline merge with SUV computations &amp;lt;br&amp;gt;&lt;br /&gt;
- QA for SUVs computation was performed by Wendy Plesniak for images with known uptake values. &amp;lt;br&amp;gt;&lt;br /&gt;
- Discovered that image cropping step (not related to automated registration pipeline and SUVs computing) smoothes the images by doing interpolation when used with default settings. Got suggestions from Steve Piper using Nearest-Neighbor interpolation (&amp;quot;no interpolation&amp;quot;) for a time being&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
- This is the new project candidate. Requested for the images with failed manual segmentation and/or segmentation with FreeSurfer. The EM Segmentation run showed most acceptable results on one of the problem images back in February &amp;lt;br&amp;gt;&lt;br /&gt;
- The workflow will be developed and deployed similar to PET/CT ROI Longitudinal study approach - all preprocessing steps will be done with Slicer modules, all runs will be performed on local end-user machines.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
 &lt;br /&gt;
&lt;br /&gt;
* August 15 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- First 5 cases with 3-4 time points preprocessed for SUVs computation&lt;br /&gt;
&lt;br /&gt;
* August 8 2010&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Testing of installation and operation at users' site (Performed by Wendy Plesniak)&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* July 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Delivered beta version of registration pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
- Prepared installation and user manuals &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* June 11, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Registration modules completed &amp;lt;br&amp;gt;&lt;br /&gt;
- Irregular cases registration problem solved (when whole body and brain only scans are mixed for a timepoint)&amp;lt;br&amp;gt;&lt;br /&gt;
- Live demo of case setup and registration workflow for end users. Real case with 4 timepoints used&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Coming week plans&amp;lt;br&amp;gt;&lt;br /&gt;
- Adjust workflow based on end users' feedback&amp;lt;br&amp;gt;&lt;br /&gt;
- Integration with SUVs computing for PET scans&amp;lt;br&amp;gt;&lt;br /&gt;
- GUI for workflows dispatching and data organizing&amp;lt;br&amp;gt;&lt;br /&gt;
- (TBD) Integration with 4D time series analysis Slicer module&amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
* May 28, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- Migration to the latest Slicer 3.6 release candidate &amp;lt;br&amp;gt;&lt;br /&gt;
- Added webservice for new registration module: BRAINSFit &amp;lt;br&amp;gt;&lt;br /&gt;
- Test runs for new patients with 4 timepoints' scans &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Plans for next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI &amp;lt;br&amp;gt;&lt;br /&gt;
- processing workflow demo for end user &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 21, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Pilot version of portable web services and automated workflow tested: &amp;lt;br&amp;gt;&lt;br /&gt;
Linux: workflow and visual review passed&amp;lt;br&amp;gt;&lt;br /&gt;
Stress test for 25 timepoints passed &amp;lt;br&amp;gt;&lt;br /&gt;
MAC OS: workflow passed, visual review failing when PET/CT images are loaded into GUI simultaneously (bug report submitted)&amp;lt;br&amp;gt;&lt;br /&gt;
Windows: need to adapt command line modules and workflow management system to sygwin environment&amp;lt;br&amp;gt;&lt;br /&gt;
Plans for next week: integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI&lt;br /&gt;
&lt;br /&gt;
* May 7, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Selected registration and resampling modules with more precise and stable outputs. &amp;lt;br&amp;gt;&lt;br /&gt;
Started building portable web services and automated workflow &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 30, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- manual walk through the processing steps: ROI cropping, registration/resampling, PET pharmaceutical DICOM data retention. &amp;lt;br&amp;gt;&lt;br /&gt;
- testing workflow and web services packages distribution to end-users' machines&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* April 23, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : testing various registration and re-sampling algorithms (work in progress)&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation: as of collaborators' request, run existing EM Segmentation workflow for older low resolution pseudo-T1 images. The EM Segmentation works for those images with manual sampling. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 16, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
  Social Cognition Study: started Cortical Thickness Measurement module build (bases on NA-MIC ARCTIC pipeline) &amp;lt;br&amp;gt;&lt;br /&gt;
  PET/CT ROI/Longitudinal Study Registration : Design specs, PET-to-CT images registration tests on training data. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 9, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. GUI update based on end-user experience.&amp;lt;br&amp;gt;&lt;br /&gt;
User request: automated label maps' volumes calculation (Currently possible from Slicer3 GUI)&amp;lt;br&amp;gt; &lt;br /&gt;
PET/CT ROI Project. Initial design specs discussion with end-users and co-developers&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure&lt;br /&gt;
Verification of segmentation workflow GUI: from registering new case to reviewing results&amp;lt;br&amp;gt;&lt;br /&gt;
Cross study test of segmentation workflow: MGH/MS Center data - success,  HIV Project data - some EM Segmentation scene tuning is needed &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*&lt;br /&gt;
* April 2, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. Segmentation workflow completed&amp;lt;br&amp;gt;&lt;br /&gt;
* Coming Week plans:&amp;lt;br&amp;gt;&lt;br /&gt;
- Document Segmentation Workflow. Follow up with end users &amp;lt;br&amp;gt;&lt;br /&gt;
- Start with Cortical Thickness and ROI-in-longitudinal studies workflows&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* March 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All essential processing and workflow interaction clients are ready.&amp;lt;br&amp;gt;&lt;br /&gt;
- Completed segmentation for 10 out of 50 patients. The remaining cases will be finalized upon manual lesion segmentation and QC verification of WM/GM/CSF and Deep GM segmentation's. &amp;lt;br&amp;gt;&lt;br /&gt;
- TODO next week: refine QC GUI and data tracking / progress monitoring schema. &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&amp;lt;br&amp;gt;&lt;br /&gt;
- New Slicer3 web services added: re-slicing with reference image volume, casting image scalar type &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
* March 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Segmentation maps Merging Services for GM/WM/CSF (Slicer EM Segemnter), Lesion (Slicer, Manual), and Deep GM (FreeSurfer)  &amp;lt;br&amp;gt;&lt;br /&gt;
- Deep GM segmentation pipeline adopted as optional service for Social Cognition Study (22 out of 50 cases processed) &amp;lt;br&amp;gt;&lt;br /&gt;
- (In progress) GUI client for Launching Segmentation results merging with optional Deep GM segmentation with FreeSurfer &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- Complete GUI Client for Segmentation result merging &amp;lt;br&amp;gt;&lt;br /&gt;
- Progress Monitoring services for entire Study processing: EM Segmenter Preprocessing, EM Segmentation, Lesion Segmentation (including human activities assignments), Deep GM segmentation, and results consolidation. &amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* March 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All 50 cases went through &amp;quot;basic&amp;quot; One-channel EM segmentation (GM/WM/CSF) &amp;lt;br&amp;gt;&lt;br /&gt;
- Basic pipeline start-up command line client created: user has two options - request brainmask extraction or provide with previously extracted brainmask for a given subject &amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison of GM/WN/CSF performed for Slicer EM Segmenter and FreeSurfer recon-all (used with default settings). &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmenter provides more accurate output &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmentation pipeline runs faster (40 minutes vs 12 hrs when no brainmask extraction requested) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO:&amp;lt;br&amp;gt;&lt;br /&gt;
- merging modules for automatic 1-channel EM segmentation and manual lesion segmentation &amp;lt;br&amp;gt;&lt;br /&gt;
- Emerge Cortical Thickness pipeline project: use NAC ARCTIC processing steps and modules &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Selected stable EM Segmentation scenario: White Matter, Gray Matter, and Cerebrospinal Fluid &amp;lt;br&amp;gt;&lt;br /&gt;
- First 16 cases are segmented for selected scenario. Nine more cases are preprocessed for EM Segmentation.&amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison to segmentation with FreeSurfer showed better accuracy for Slicer2 EMSegmenter &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure &amp;lt;br&amp;gt;&lt;br /&gt;
- Three prerpcocessed cases failed during volume ICC masking with in-house build utility. Evaluated switching to Slicer3 Mask and island removing modules.&amp;lt;br&amp;gt;&lt;br /&gt;
- Initial design specs discussion for cortical thickness measurement pipeline. ARCTIC pipeline selected. ARCTIC preprocessing steps signifficantly overlap with EM Segmentation preprocessing workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
  &lt;br /&gt;
* February 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: &amp;lt;br&amp;gt;&lt;br /&gt;
A) parameters tuning for EM Segmenter itself (work with EM Segmenter developer), template scenes creation &amp;lt;br&amp;gt;&lt;br /&gt;
B) update preprocessing pipeline - deep gray matter atlases included &amp;lt;br&amp;gt;&lt;br /&gt;
C) test and debug preprocesing pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
D) identified missing modules: atlas autocalibration for EM Segmentation scene, Island removal for ICC mask&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- Review currently deployed modules. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: reviewed firts seven subjects' outputs, added volume orientation module into pipeline (prevents ICBM atlas linear registration failures)&amp;lt;br&amp;gt;&lt;br /&gt;
- Fused ICC(brainmask) extraction module with EM Segmenter preprocessing. Three scenarious implemented: start with pre-extracted ICC mask (longitudinal studies case), run with ICC ectration, run with ICC extraction AND ICC correction before ICBM atlas preporcessing. &amp;lt;br&amp;gt;&lt;br /&gt;
- Completion of Human activities GUI (QC, ICC Correction) planned for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: Volume Orientation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: automated preprocessing pipeline for Slicer2 EM Segmenter test version deployed. Seven cases pre-processed.&lt;br /&gt;
- PET Quantitative measurements: Preliminary design specs discussion.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: BSplineRegistration (for non-linear registration), ResampleVolume2 (for atlases resampling based on image atlase templates registration). Local and Network runs are implemented, Cluster/GridWizard implementation pending.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Slicer EM Segmenter module: preprocessing design for Slicer2 EM Segmenter&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Adapting for Slicer2 EM Segmenter (mostly from pipelines and services for previous projects)&lt;br /&gt;
  -- Integration with FreeSurfer modules for bisafield correction, brainmask extraction, and linear registration of ICBM atlases&lt;br /&gt;
  -- Preprocessing updates for non-linear registration of ICBM atlases with Slicer2 (image re-orientation service designed)&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 29, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- EM Segmentaton pipeline: preprocessing results are being transferred to XNat (anonymized data, Central XNat) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Slicer EM Segmenter module: discussed agenda and scheduled a work meeting for Social Cognition Study image segmentation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Testing stage, 95% completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- SPL XNat server: verified data exchange via RESTfull web services.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 22, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Follow up with White Matter Lesion Segmenter and Scull Stripping Modules developers: Work in Progress&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Work in Progress, 60%+ completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Discussed SPINE image repository migration to XNat&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 15, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. &lt;br /&gt;
- Social Cognition Study: &lt;br /&gt;
Work-in-progress on intermediate (reconstruction) and results (resources) data storage at XNat.&lt;br /&gt;
&amp;lt;br&amp;gt;Reviewing and preparation more cases for EM Segmentor (Slicer 3.5) tuning.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* NA-MIC Project Week&lt;br /&gt;
Selecting candidate Slicer modules for other than Lesion EM Segmentation topics of Social Cognition study: Withe Matter Lesion Segmenter (UNC), Scull Stripping utility from UIOWA.&lt;br /&gt;
Reviewing issues of currently used Scull Stripping Slicer Extension and Slicer 3.5 EM Segmenter.&lt;br /&gt;
&amp;lt;br&amp;gt;XNat Data organizing training&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 1, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Preparation of Demo for NA-MIC work week: &lt;br /&gt;
- COPD Study. Added Remote pipepline start interface (represents real world scenario where Xnat repository, Processing modules and User are at different sites)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
- EM Segmentation. Added human activities steps to the workflow: ICC (brainmask) correction and EM Segmantation scena load per se.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 25, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Pilot workflow pipeline for EM Segmentation (all steps except user-activity step: ICC correction assignment and tracking)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 18, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Build and tested web services for EM Segmentation image preprocessing: DICOM-to-NRRD conversion, registration, skull stripping, image masking.&lt;br /&gt;
Started building workflow pipeline (subject to finish first version next week)&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Started Collecting Library of Slicer Build number vs. functional modules and extensions.&lt;br /&gt;
Plan for NAMIC project week: scheduled meetings for XNat data customization, Skull-stripping modules tuning, identified Social Cognition study cases that fail EM Segmentation processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 11, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Updating and verification of EM Segmentation Scenario&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Projects:ARRA:SlicerWF:UseCaseScenarios#Usecase_MS_lesion_Assessment&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Familiarizing with Slicer3.4/5 Modules required for implementation of EM Segmentation Scenario. Participation in debugging and/or usage tuning of Dicom Conversion, Registration, Skull Stripping, Masking, and Image Casting modules. &lt;br /&gt;
&lt;br /&gt;
* December 4, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Slicer3.4's EM Segmentation and Visual QC as part of image processing pipeline for Social Cognition Study for MS Patients.&lt;br /&gt;
Project emerged. EM Segmentation template creation debugged.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
Emphysema Measurements (COPD Study) - workflow stability and scalability test.&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 27, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Emphysema Measurements (COPD Study).&lt;br /&gt;
Added compensation for long running calculations and time-outs to the main computing pipeline.&lt;br /&gt;
Visual QC (work in progress)&lt;br /&gt;
** Infrastructure&lt;br /&gt;
XNat data structure customization, metadata storage, results consolidation: new feature request list creation (work in progress)&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 13, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
*** Pilot system for whole processing cycle for Emphysema Measurements (COPD Study) including the following:&lt;br /&gt;
Web query for CT session file list download&lt;br /&gt;
Pilot user interface for submitting the file list and starting processing pipeline&lt;br /&gt;
Notification about processing steps and failures&lt;br /&gt;
Upload results to XNat repository (at this stage results are uploaded into same folder where original scans are(*))&lt;br /&gt;
*** Immediate Plans&lt;br /&gt;
Complete Visual QC module&lt;br /&gt;
Design and implement meta-data transfer to XNat (including processing details and MRML files for loading images into the 3D Slicer)&lt;br /&gt;
&lt;br /&gt;
(*)Customization of results storage&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 6, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Tuned and debugged multiple subjects processing for: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat.&lt;br /&gt;
***Started working on quality control embedding into the above scenario. Plan to complete and video-record demo next week.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***Published general Product Integration scenario flow chart to collaborators' community. Discussion is open and in progress&lt;br /&gt;
&lt;br /&gt;
* October 30, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Piloted and tested the sequence: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat(1).&lt;br /&gt;
***Performance test of overall cycle: data transfer from remote serve is a bottleneck as expected&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data browsing features reviewed.&lt;br /&gt;
(1) Not automated yet&lt;br /&gt;
* October 23, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Defined COPD processing scenario with interoperability between Xnat, 3D Slicer Command Modules, Workflow, and Gridwizard Enterprise.&lt;br /&gt;
***Pilot version of Emphysema Measurements workflow pipeline deployed.&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data transfer features reviewed. Use account at XNat Central during learning curve.&lt;br /&gt;
***Feasibility test of 3D Slicer fiducials module for ROI highlights during QC and manual image processing activities. &lt;br /&gt;
* October 16, 2009&lt;br /&gt;
**Lung CT Scans Processing. Pilot project emerged. GenerateEmphysemaMeasurements module deployed as a webservice that submits jobs to computational cluster.&lt;br /&gt;
**EM Segmentation. Familiarized with GUI steps. Started working on automation steps outlining&lt;br /&gt;
**3D Slicer and XNat interaction. Got an overview from Wendy Plesniak.&lt;br /&gt;
* October 1 - 7, 2009&lt;br /&gt;
**Selected two first priority Projects: EM Segmentation of brain MRI images; Lung CT Scans Processing (COPD Study)&lt;br /&gt;
**Got initial outline of user requirements and design specs&lt;/div&gt;</summary>
		<author><name>Azaitsev</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=File:SlicerWF_EMSegmentProjectsReview.zip&amp;diff=66927</id>
		<title>File:SlicerWF EMSegmentProjectsReview.zip</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=File:SlicerWF_EMSegmentProjectsReview.zip&amp;diff=66927"/>
		<updated>2011-04-29T16:55:03Z</updated>

		<summary type="html">&lt;p&gt;Azaitsev: Projects' review that include EM Segmentation as a part of workflow process: Image parameters and Screenshots are included&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Projects' review that include EM Segmentation as a part of workflow process: Image parameters and Screenshots are included&lt;/div&gt;</summary>
		<author><name>Azaitsev</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=66841</id>
		<title>Projects:ARRA:SlicerWF</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=66841"/>
		<updated>2011-04-25T14:14:16Z</updated>

		<summary type="html">&lt;p&gt;Azaitsev: /* Progress */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Projects:ARRASuplements|Back to Slicer ARRA home page]]&lt;br /&gt;
= Aim =&lt;br /&gt;
Supplement 3D Slicer and Extensible Neuroimaging Archive Toolkit (XNAT) with workflow management system. Provide integration and interoperability between 3D Slicer, XNAT Services and 3-rd party image processing applications and high performance computing systems. Implement it as within currently developed Structural Planning and Implementation in Neurological Exploration (SPINE) System.&lt;br /&gt;
&lt;br /&gt;
= SPINE Project Documentation =&lt;br /&gt;
[http://cni.bwh.harvard.edu/projects/spine/index.html SPINE Docs]&lt;br /&gt;
&lt;br /&gt;
= Presentations =&lt;br /&gt;
* Segmentation Workflow. PECS University Social Cognition Study.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:SlicerWF_NAC_PECS_Workflow.pdf]]&lt;br /&gt;
* EAB10_ARRA Annual Progress Report Slides.&amp;lt;br&amp;gt;&lt;br /&gt;
[[media:EAB10_ARRA_WF_2011_Zaitsev.ppt | Service Oriented Solutions for 3D Slicer. EAB10_ARRA_WF_2011. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:EAB10_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:NAMIC_ARRA_WF_2011_Zaitsev.ppt  | NAMIC Annual Report 04/2010-03/2011. NAMIC_ARRA_WF_2011_Zaitsev. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:NAMIC_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:Slicer_WF_Slicer4CARMAWorkflow.ppt  | CARMA Workflow. Cardiac Ablation Followup. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:Slicer_WF_Slicer4CARMAWorkflow.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
= All Hands Meeting Pages =&lt;br /&gt;
* Salt Lake City 2011 Winter [http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA SLC_2011_WorkFlow]&lt;br /&gt;
* MIT 2010 Summer [http://wiki.na-mic.org/Wiki/index.php/Summer_project_week_2010_Workflows_SOA MIT_2010_WorkFlow]&lt;br /&gt;
&lt;br /&gt;
= Research Plan =&lt;br /&gt;
*Create a stand-alone SPINE desktop agent with fully functional data exchange and communication mechanisms towards 3D Slicer and XNAT.&lt;br /&gt;
*Develop Service Oriented Architecture (SOA) SPINE System that will include 3D Slicer image processing modules deployed as web services as well as a workflow management system to orchestrate interaction between 3D Slicer, XNAT, and 3-rd party tools.&lt;br /&gt;
*Implement two-way control and communications between 3D Slicer and SPINE modules.&lt;br /&gt;
*Adapt SPINE System for cluster and grid computing scenarios.&lt;br /&gt;
*Provide with workflow and 3D Slicer web service wrappers editing tools.&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:UseCaseScenarios| Use Case scenarios]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PETCTWorkflow| PETCTWorkflow]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:AgingStudySegmentation| AgingStudySegmentation]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:TwoTensorTractography| TwoTensorTractography]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:LongitudinalMultimodalityRegistrationSuite| LongitudinalMultimodalityRegistrationSuite]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:MigrationJavaClients2QT| MigrationJavaClients2QT]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PediatricMSSegmentation| PediatricMSSegmentation]]&lt;br /&gt;
*[[DBP3:Utah:RegSegPipeline| MRI-based study and treatment of atrial fibrillation]]&lt;br /&gt;
&lt;br /&gt;
= Application Server / Workflow Engine Downloads =&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:WFEngineDownloads| Download Links]]&lt;br /&gt;
&lt;br /&gt;
=Key Personnel=&lt;br /&gt;
* Charles Gutmann, MD., 4%,  9-17-2009 through 9-16-2011&lt;br /&gt;
* Alexander Zaitsev, Ph.D., 75%, 9-17-2009 through 9-16-2011 &lt;br /&gt;
&lt;br /&gt;
=Annual Progress Statements =&lt;br /&gt;
'''2010-11''' &amp;lt;br&amp;gt;&lt;br /&gt;
The  April 2011 – March 2011 period was devoted on developing portable workflow solutions that can be deployed on end-users' workstations or notebooks with minimal or no system administration activities. This is in contrast to the server-side deployment. The following scenarios had been deployed and used for actual projects that require the following types of workflows: PET/CT registration and computation of biomarker driven brain physiological activities, Brain MRI Images segmentation,  MRI and MRI Angiography images pre-processing for cardiac ablation outcome estimation. Some  workflows (like EM Segmentation) had been utilizing various scenarios, some research projects  (like evaluation of chemotherapy outcome) require two types of workflows to assess physiological and structural changes. Starting from the 4th Quarter of 2011, the migration project had been emerged in order to embed Workflow GUIs into newly developed Slicer4 Suite. The existing rich client Java GUI applications are being re-written as C++/QT Sliceletts units, new modules (such as cardiac ablation project support) are had been written from scratch. The latter are being deployed from the Slicer4 GUI and act at a liaison between Slicer4 and Application Server containing  workflow and Slicer modules deployed as services. The feedback from the end users indicates that Workflow approach for the complex processing improves productivity, aids to the processing standardization and contributes to the overall experience using 3D Slicer&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
=Quarterly Progress=&lt;br /&gt;
&lt;br /&gt;
* NAMIC Annual Progress Slides (April 2010 - March 2011):&lt;br /&gt;
&lt;br /&gt;
* '''1st Qtr, 2011''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study: Second release is under testing by end-users. &lt;br /&gt;
*** Added MRI registration to aid ROI drawing on PET scans&lt;br /&gt;
*** Improved SUV results reporting and added flexibility to update ROI lookup table&lt;br /&gt;
*** Automated EM Segmentation of MRI images for computing SUVs for white matter, CSF, and whole brain (80% completion)&lt;br /&gt;
*** Integration with SPECTRE scull stripping module (70% completion) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** EM Segmentation: Automated WF Pipelines are created &amp;lt;br&amp;gt;&lt;br /&gt;
*** Flexible atlas selection (Pediatric, etc) feature added&lt;br /&gt;
*** Workflows implemented for EM Segmenter 3.6.2 and 3.6.3 (1st Qtr 2011 release)&lt;br /&gt;
&lt;br /&gt;
** Cardiac ablation results follow-up: Workflow for registration and ROI selection of cardiac MRI and MR Angiography &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Wrokflow and Web Services for prospective DTI tractography modules (currently written as Matlab modules at PNL) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Web Services for SPECTRE Scull stripping module&lt;br /&gt;
*** Accuracy and performance tuning&lt;br /&gt;
*** 50% completion&lt;br /&gt;
&lt;br /&gt;
** Migration Front End GUI to Slicer4/QT:&lt;br /&gt;
*** EM Segmentation&lt;br /&gt;
*** Cardiac Ablation Study&lt;br /&gt;
&lt;br /&gt;
** DICOM Uploader and Desktop Browser for XNat Image repository (alpha version - tested for MGH MS Center studies, proposed to use with MI2B2 Clients and Services)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''4th Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study and EM Segmentation for Aging Study are deployed at end-user sites and actively used for research. &lt;br /&gt;
** Adopted EM Segmentation preprocessing pipeline for HIV Study: high resolution SPGR images, integration with FreeSurfer brainmask extraction outputs; integration of Slicer SPECTRE module for brainmask extraction is in progress.&lt;br /&gt;
** The following post-release upgrades had been implemented based on end-user feedback: Application Server basic controls are performed from Rich Client GUI as alternative to traditional IT administration activities. The controls are implemented on point-and-click bases and include web services and workflow application deployment and upgrades, application server start and stop as well as warning end user when the server is not accepting request.&lt;br /&gt;
** Added DICOM downloads and results uploads of PET/CT pipelines from and to XNat Repository&lt;br /&gt;
** Created Services and Workflow for Matlab Prototypes modules. Case Study: tractography for DTI images&lt;br /&gt;
** Extended XNAT integration services:&lt;br /&gt;
*** Browsing capabilities of XNat data repository from the Workflow Applications&lt;br /&gt;
*** Improved DICOM upload and download performance&lt;br /&gt;
*** Added Metadata organizing services for uploaded DICOM images: header data extraction, image snapshots creation. &lt;br /&gt;
** Started project for Rich Client GUI migration from Java desktop application to build into SLicer4 QT modules. This affects mostly front-end GUI and has the following approaches: distribution with the Slicer4, end-user will select desired workflow application from Slicer4 menu while QT-written modules provide with the same functionality as Java Rich Clients. Case Study for the Migration process: registration suite for longitudinal studies that include multi-modality images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* '''3d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Concentrated on building downloadable workflow applications that could run both in desktop (new) and server environment, and that require minimum IT administrative resources. The desktop deployment is in compliance with Slicer3 general deployment concept.&lt;br /&gt;
*** The following use case scenario had been chosen: PET/CT image processing for longitudinal studies, EM Segmentation for longitudinal Aging Study.&lt;br /&gt;
** Released workflow application for PET/CT image processing for longitudinal studies. Provided end users with training and documentation.&lt;br /&gt;
*** The PET/CT processing workflow was designed to be a general application used whenever both structural patterns and metabolic activities are within the research scope. &lt;br /&gt;
*** The desktop version is tuned to use minimal computer resources, so the automates processing instances do not interfere with human activities. Automated activities may include, for example, registration and PET scan's standard uptake values computing, and manual human activities may include image cropping, quality control, and labeling voxels of interest.&lt;br /&gt;
** Core services and EM Segmentation preprocessing workflow was build for retrospective Aging Study. Tuned the Slicer3 webservices for processing low grade images acquired in mid 90s. Entire workflow is implemented with Slicer3 only modules and can be deployed locally and on the servers. Usage of Service Oriented Architecture (SOA) as a core technological approach allowed reusing most of the web services that had been build for PET/CT project. &lt;br /&gt;
** Continued embedding Slicer3 application and modules into previously released processing pipelines: replaced MIPAV with Slicer3 GUI for lesion assessment step in the multi-center Pediatric MS Cohort image processing &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''2d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Completed Social Cognition Workflow Implementation. This includes EM Segmetnation pre- and post-processing pipelines, data tracking, and integration with 3d party image processing utilities, as well as processing results acquired manually with Slicer GUI.  &lt;br /&gt;
** Multi-modality image registration and ROI selection/alignment workflow for longitudinal studies. &lt;br /&gt;
*** Use case: PET/CT image processing for longitudinal studies. &lt;br /&gt;
*** Build portable library of Slicer modules as web services and workflow that are deployed and run on a end-users' worksatations without utilization of SPL and other servers. The web services include novel Slicer3 modules, such as BRAINSFit and BRAINSResamle &lt;br /&gt;
*** Started working with Slicer3 developers on Slicer 3.8 GUI wizard to communicate with workflow instances.&lt;br /&gt;
** Participated at NA-MIC Summer 2010 Project Week: [[Summer_project_week_2010_Workflows_SOA]]&lt;br /&gt;
&lt;br /&gt;
=Progress=&lt;br /&gt;
* April 22, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Beta release ready. Demo Location: http://cni29.bwh.harvard.edu/SlicerWFDemo/index.php&lt;br /&gt;
* TODO: Tutorial. Original inputs copy/renaming&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 15, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Adding App server auto-config features&lt;br /&gt;
* Finalizing the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 08, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Second release beta build tested on cosutmer side &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review registration quality (with Dr. Meier). Angiography images' Resampling tuned. &lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 01, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the second release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
XNat Integration&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* (Java) GUI for Project Browsing and DICOM Series Upload. Post-upload DICOM processing tested and debugged&amp;lt;br&amp;gt;&lt;br /&gt;
* Ready for integration with mi2b2 client.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Migrated to Latest Slicer 3.6.3 stable release: only the Input scene had to be updated, the API remained the same&lt;br /&gt;
* Tested EM Segmenter with CMTK4Slicer extension - processing takes to much time on Linux_64bit machine, rolled back to BRAINSFit registration. When used on Mac OS X build, the Slicer could not start (bug report 1126).&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SPECTRE Scull Stripping:&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Testes for various use cases: the module is extremely sensitive to T1 MRI quality (does not work for most MRIs from PET/CT project&lt;br /&gt;
* TODO next week: check for FLAIR images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Slicer4 QT GUI and Cropping activity in progress.&amp;lt;br&amp;gt;&lt;br /&gt;
* Tried direct MRA to MRA registration option: resampling with LMRI registration transforms works better.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Extra VOI labels revised&lt;br /&gt;
* Debugging of SUV results' renormalization step&lt;br /&gt;
* TODO: ICC extraction / whole brain total uptake computing; EM Segmentation for R_WM, L_WM SUV computing and BPH estimation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SCULL STRIPPING/SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Installed and tested CLI option on Linux_64bit platform&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Workflow interruption before BSPline registraton: BPEL Module completed. Slicer4 QT GUI and Cropping activity in prorgess.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Implemented and Tested with end-users proposed changes: denormalization of SUV results, adding more VOI labels, added FLAIR MRI in addition to T1s for VOI drawing&lt;br /&gt;
* Tested manual ICC extraction using PET scans: works satisfactory with island removal and cropping followed by threshold level labeling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4&lt;br /&gt;
* Change proposed: interrupt workflow after affine registration and have user crop the VOI. This is to prevent excessive deformations for BSpline registration and resampling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4. User has option to choose the atlas that fits better for the given subject (NOTE: hardcoding must be rewritten for atlas linking)&lt;br /&gt;
* PETCT test - the problem is that T1s are low resolution and with contrast. Proposed using T1s without contrast&lt;br /&gt;
* PETCT change request: users wants to compute SUV for entire ICC. Had demo how to segment brainmask/ICC using PET scan. The derived brainmask label can be used for SUV computation.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - cmpleted&lt;br /&gt;
* Sample cases run - excessive deformation after BSpline registration hase&lt;br /&gt;
* Next week plan - pull tuning controls to front-end of pipeline API, start working of QT module for CARMA registration&lt;br /&gt;
* May consider other than BRAINSFit registration modules&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Design plan for change request: more VOI labels, add FLAIR in addition to T1 for VOI drawing, T1s segmentation&lt;br /&gt;
* Tested segmentation for sample cases - artifacts from poor quality MRIs lead to exclusion of parts of ICC from segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Completed troubleshooting of EMSegmenter module calling from Java (need TCL libs to be pulled from Slicer environment)&lt;br /&gt;
* Tested EMSegmenter autoruns for HIV and Pediatric MS patiens. Work as expected, subject to improvement of PED MS case segmentation by building better skull/neck/air atalses&lt;br /&gt;
* Suggested usage of two subsets of atalases: with and without neck. The Subject MRIs have to be cropped accordingly or best fit atlas has to be selected&lt;br /&gt;
* Made no-neck cropped atlas collection for default EMSegmenter scenario&lt;br /&gt;
* Tested with PET/CT study MRI cases - see above &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - in progress&lt;br /&gt;
* Next week goal - have back end processing ready&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Longitudinal Study&lt;br /&gt;
* Added MRI registration to the pipeline&lt;br /&gt;
* Troubleshooting of complex XML schema issues on Linux machines (some modules working on MAC do not work on Linux). As a workaround - did not include MRI convert and register part into base BPEL module. Used separate services (transparent for end-user)&lt;br /&gt;
* TODO next week for change request completion: explicit pixel type casting for MRI in BRAINSFit, VOI MRML scene update (currently MRI added on top of schema)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* February 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipeline for Pediatric MRI. Same scenario as for HIV Project, icbm pediatric atlases (Completed, verified)&lt;br /&gt;
* Collected NIH healthy brain development atlases: various age ranges from 4.5 to 18 yo. Converted to Slicer readable format &lt;br /&gt;
* Work on web services for the new automated EM Segmenter module (release Nov 10 - current). Verified task completion both for adult and pediatric images. Discussed tuning parameters for work load balance on workstations.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Started working on MRI registration to the reference CT scans. &lt;br /&gt;
* Design specs for optional White Matter segmentation for SUV computing.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* February 4, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipelines for Pediatric MRI (in progress)&lt;br /&gt;
* Adapting Pediatric T1 atlases for &amp;quot;Human Brain&amp;quot; build-in EM Segmentation wizard (in progress)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 28, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Verifying EM Segmenter module for latest builds and HIV/PED MS Studies (report pending)&lt;br /&gt;
* Work with SPECTRE module developers with pediatric MRI brainmask extraction&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* January 21, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Compiling plan for WF FrontEnd GUI migration to Slicer4/QT Widgets&lt;br /&gt;
* Preparing for annual progress report&lt;br /&gt;
&lt;br /&gt;
* January 14, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI: Integrated into the Slicer4 as Slicelet (or thin Client)&lt;br /&gt;
* Participation at AHM-2011, discussing integration of SPECTRE module and updated approach to EM-Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA&lt;br /&gt;
&lt;br /&gt;
* January 7, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* HIV project workflow delivered. Major additions relate to user convenience: &lt;br /&gt;
- Project-specific parameter settings, importing T1s and brainmasks from FreeSurfer outputs with conversion to NIFTI, resampling brainmask to original scans and automatied subject addition.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Follow up with end user: need to add MRI scans, if available, addition and registration to CT in order to ease VOI drawings.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
 &lt;br /&gt;
* December 31, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Follow-up with user Experience for AGING Study Segmentation (Positive feedback)&lt;br /&gt;
* Target date for HIV project delivery - next week&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Self-training for QT widget development&amp;lt;br&amp;gt;&lt;br /&gt;
* Outlined Workflow Rich Clients migration strategy from Java to QT/Slicer4:&amp;lt;br&amp;gt;&lt;br /&gt;
** Use Java Stubs (similar to SPECTRE integration) or file binding for envocation of workflow pipelines. (See SOAP remark below)&lt;br /&gt;
** Direct Web Servisec calls must be wrapped into REST protocol. The reason: NON-commerchial QT kit does not include SOAP protocol for web servises.&lt;br /&gt;
** The GUI will be implemented as page widget or QT dialog GUI forms called from within Slicer4.&lt;br /&gt;
** Communications between Slicer4 and WF GUI will be set via child-parent and signal-slot relations&lt;br /&gt;
* Worked on a Prototype for Basic EM Segmentation QT widget (70% complete). Will work on integrtion with SLicer4 during the AHM-2010&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
XNAT Integration&lt;br /&gt;
* Debugged XNAT RESTFul API usage for uplaoding DICOM series followed by header data extraction and image snapshots creation&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Added compensation for failed atlas registration (subject for old poor quality pseudo-T1 images): blank probability maps are created in case of failure.&lt;br /&gt;
* Data preparation module for FreeSurfer data import near completion. Expected time for deployment at end-users workstations - first week of January&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Discussed strategy for EM Segmentation pipeline solutions collection (K. Pohl, R. Kikinis)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* RE-using the same core workflow as for 1-channel EM Segmentation of AGING STUDY cases&lt;br /&gt;
* Added data input preparation module: ICC label mask preparation and skull-stripping based on FreeSurfer brainmask output volume.&lt;br /&gt;
* Two-channel EM segmentation pipeline (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE / GENERAL Development &amp;lt;br&amp;gt;&lt;br /&gt;
* Worked on plans for migrating fro rich workflow Java clients to embedded workflow windows inside the Slicer.&amp;lt;br&amp;gt;&lt;br /&gt;
The embedded workflow management clients are to be implemented with QT/PyQT toolkits&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
INTEGRATION WITH XNAT:&amp;lt;br&amp;gt;&lt;br /&gt;
* Automated DICOM series upload with triggering DICOM headers parsing at XNat site (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress. &lt;br /&gt;
- Results upload to XNat (Completed) &amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat based on user's input (Project + Subject + PET or CT session / scan) (Completed)&amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat - perfomance boosting solution for downloads found , web services services are created, relinking for the client side in progress &amp;lt;br&amp;gt;&lt;br /&gt;
- Xnat querying for subjects and automated subject addition into the workflow (In Progress) &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-segmentation module added for auto correction of segmentation results. Particularly - relabeling CSF voxels segmented as Air inside the intracranial cavity. This was requested by end-users after processing images with zero-signals in CSF voxels &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting automated dual-echo DICOM images conversion and split into two NRRD volumes&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT / EM Segmentation pipeline:&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting memory allocation issues for scull-stripping module SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
COPD Project:&amp;lt;br&amp;gt;&lt;br /&gt;
* Benchmark test for accelerated DICOM downloads from XNat (remoote XNat Central server): we can handle at least 6 cases (4 CT scans in each) per hour, which is compatible with current workload quotes on SPL cluster processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* December 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Deployed Version 1. &amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Test project chosen as a closest match to registration scenario: Pediatric MS Cases from MGH - requires periodic image preview for different &lt;br /&gt;
modalities taken from vaious time points. Label maps for VOIs resampling is also required.&lt;br /&gt;
&lt;br /&gt;
* November 26, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user. Version 1 is complete&amp;lt;br&amp;gt;&lt;br /&gt;
* Started working on integration with XNat&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on input data organizing modules&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 19, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user (70% done)&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Universal Registration Workflow for Longitudinal Studies - design specs in progress&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 12, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Minor tuning to EM Segmentation template as of users' feedback&lt;br /&gt;
* Users started using the workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed input data conversion from Genesis to Slicer native or NIFTI format. Our help may be needed in input data organizing.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Tuned application according to co-laborators (PNL) needs&amp;lt;br&amp;gt;&lt;br /&gt;
* The webservices and BPEL workflow application are tested ready to accept computation requests from PNL case tracking system &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Discussed Universal Registration Workflow for Longitudinal Studies&lt;br /&gt;
* Started the thread about possible cooperation with Children hospital's image processing pipelines and integration with Xnat &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 5, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Webservices and workflow pilot project created and deployed on Psychiatry Neuroimaging Laboratory subnet &amp;lt;br&amp;gt;&lt;br /&gt;
* The V.1.0 deployment is scheduled for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 29, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Most of functionality is completed. Some volume statistics post processing is pending&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL EM SEGMENTATION Pipeline: &amp;lt;br&amp;gt;&lt;br /&gt;
* The SPECTRE scull stripping module. Started integration into EMS workflow. Made some test runs from Slicer GUI&amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Identified as a candidate for Workflow Application&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 22, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* All back-end functionality are implemented&amp;lt;br&amp;gt;&lt;br /&gt;
* EM Segmentation scene usability is confirmed by end-user&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for next week: add Label Statistics computation for CSF/Brain/ICC &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 15, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* The latest (October) builds of Slicer 3.6.2 produced acceptable results. This was verified by the target users. The EM Segmentation will be performed on Slicer 3.6.2 or later&amp;lt;br&amp;gt;&lt;br /&gt;
* The new Web services had been created and added to the pipeline as optional processing steps: Biasfield correction (implement novel N2ITKBiasFieldCorrection module) and Volume's scalar datatype casting (as workaround for Biasfield correction module not preserving image scalar datatype - the bug is filed) &amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed the Front-End GUI design with target users. The design pattern is taken from the PETCT project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 8, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-deployment support. Tuned CT registration as of user's feedback.&lt;br /&gt;
* Adapting to the Single Slicer build: Slicer 3.6.2. Found label duplicates in the label lookup table - will ask user if it's tolerable. Waiting for the Slicer 3.6.2 build that contains all required modules. Rolling back label tag appending code for SUVs - the latest Slicer build appends the tags.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Resumed development. The priorities are set for usage of Slicer 3.6.2 - subject for EM Segmentation scene tuning. Continued coding for Scene creation for Slicer 2.8 - as a backup option for ongoing research project.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 1, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized V1.0 release based on end-user feedback: updates relate mostly to error proofing and SUV values representation&lt;br /&gt;
* Post-deployment support. Users pre-processed first set of patients &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* September 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* System deployed and tested at End Users' site.&amp;lt;br&amp;gt;Users are trained to perform all tasks required by the workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
* Got positive feedback with suggestions on Slicer Scenes' layouts improvement and PET scans' SUV (standard uptake values) results display&lt;br /&gt;
* Two distribution packages are assembled: Lunix and MAC OS versions. The difference in two packages is in specific Slicer3.6/3.7 builds - subject to Slicer Linux builds debugging.&amp;lt;br&amp;gt; As a workaround for Linux deployment - multiple Slicer builds are used to perform various tasks (registration, opening editing scenes in Slicer, SUV computing)&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for coming week - finalize V1.0 release based on end-user feedback&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Embedded SUV computations into the workflow (as system calls - will be translated into web service later)&amp;lt;br&amp;gt;&lt;br /&gt;
* Pre-release demo for end users.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Create and debug EM Segmenter scenes template for Slicer 3.6 and 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* September 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation - workflow pipeline and deployment verified&amp;lt;br&amp;gt;&lt;br /&gt;
* Tested EM Segmentation scenes within Slicer 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
* Started migration of EM Segmentation to Slicer 3.6. Discovered issues had been reported to EM Segmenter module designers &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* August 29 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation completed. Preprocessing Pipleine completed 80% (subject for input registration parameters tuning) &amp;lt;br&amp;gt;&lt;br /&gt;
* Most webservices (for registration and resampling steps) had been taken and re-used from PET/CT ROI/Longitudinal Study - showing the advantage of service-oriented software design and deployment.&lt;br /&gt;
* Continued on distribution and deployment of the service/workflow applications: on PET/CT and AGING STUDY projects.&lt;br /&gt;
&lt;br /&gt;
PEDIATRIC Multiple Sclerosis Cohort. Support of multi-center distributed processing project&amp;lt;br&amp;gt;&lt;br /&gt;
* Introduced Slicer 3.6 for the MS Lesion Assessment step performed at Mayo Clinic. Images are being transferred from image repository at BWH and automatically opened and arranged within Slicer GUI for reading.  This was replacement of Client GUI using MIPAV that stopped working on new computers at Mayo Clinic.&lt;br /&gt;
The images are being loaded via generated MRML Scenes same way as in PET/CT and AGING STUDY projects &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* August 22 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Preprocessing pipeline merge with SUV computations &amp;lt;br&amp;gt;&lt;br /&gt;
- QA for SUVs computation was performed by Wendy Plesniak for images with known uptake values. &amp;lt;br&amp;gt;&lt;br /&gt;
- Discovered that image cropping step (not related to automated registration pipeline and SUVs computing) smoothes the images by doing interpolation when used with default settings. Got suggestions from Steve Piper using Nearest-Neighbor interpolation (&amp;quot;no interpolation&amp;quot;) for a time being&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
- This is the new project candidate. Requested for the images with failed manual segmentation and/or segmentation with FreeSurfer. The EM Segmentation run showed most acceptable results on one of the problem images back in February &amp;lt;br&amp;gt;&lt;br /&gt;
- The workflow will be developed and deployed similar to PET/CT ROI Longitudinal study approach - all preprocessing steps will be done with Slicer modules, all runs will be performed on local end-user machines.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
 &lt;br /&gt;
&lt;br /&gt;
* August 15 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- First 5 cases with 3-4 time points preprocessed for SUVs computation&lt;br /&gt;
&lt;br /&gt;
* August 8 2010&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Testing of installation and operation at users' site (Performed by Wendy Plesniak)&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* July 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Delivered beta version of registration pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
- Prepared installation and user manuals &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* June 11, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Registration modules completed &amp;lt;br&amp;gt;&lt;br /&gt;
- Irregular cases registration problem solved (when whole body and brain only scans are mixed for a timepoint)&amp;lt;br&amp;gt;&lt;br /&gt;
- Live demo of case setup and registration workflow for end users. Real case with 4 timepoints used&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Coming week plans&amp;lt;br&amp;gt;&lt;br /&gt;
- Adjust workflow based on end users' feedback&amp;lt;br&amp;gt;&lt;br /&gt;
- Integration with SUVs computing for PET scans&amp;lt;br&amp;gt;&lt;br /&gt;
- GUI for workflows dispatching and data organizing&amp;lt;br&amp;gt;&lt;br /&gt;
- (TBD) Integration with 4D time series analysis Slicer module&amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
* May 28, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- Migration to the latest Slicer 3.6 release candidate &amp;lt;br&amp;gt;&lt;br /&gt;
- Added webservice for new registration module: BRAINSFit &amp;lt;br&amp;gt;&lt;br /&gt;
- Test runs for new patients with 4 timepoints' scans &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Plans for next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI &amp;lt;br&amp;gt;&lt;br /&gt;
- processing workflow demo for end user &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 21, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Pilot version of portable web services and automated workflow tested: &amp;lt;br&amp;gt;&lt;br /&gt;
Linux: workflow and visual review passed&amp;lt;br&amp;gt;&lt;br /&gt;
Stress test for 25 timepoints passed &amp;lt;br&amp;gt;&lt;br /&gt;
MAC OS: workflow passed, visual review failing when PET/CT images are loaded into GUI simultaneously (bug report submitted)&amp;lt;br&amp;gt;&lt;br /&gt;
Windows: need to adapt command line modules and workflow management system to sygwin environment&amp;lt;br&amp;gt;&lt;br /&gt;
Plans for next week: integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI&lt;br /&gt;
&lt;br /&gt;
* May 7, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Selected registration and resampling modules with more precise and stable outputs. &amp;lt;br&amp;gt;&lt;br /&gt;
Started building portable web services and automated workflow &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 30, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- manual walk through the processing steps: ROI cropping, registration/resampling, PET pharmaceutical DICOM data retention. &amp;lt;br&amp;gt;&lt;br /&gt;
- testing workflow and web services packages distribution to end-users' machines&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* April 23, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : testing various registration and re-sampling algorithms (work in progress)&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation: as of collaborators' request, run existing EM Segmentation workflow for older low resolution pseudo-T1 images. The EM Segmentation works for those images with manual sampling. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 16, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
  Social Cognition Study: started Cortical Thickness Measurement module build (bases on NA-MIC ARCTIC pipeline) &amp;lt;br&amp;gt;&lt;br /&gt;
  PET/CT ROI/Longitudinal Study Registration : Design specs, PET-to-CT images registration tests on training data. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 9, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. GUI update based on end-user experience.&amp;lt;br&amp;gt;&lt;br /&gt;
User request: automated label maps' volumes calculation (Currently possible from Slicer3 GUI)&amp;lt;br&amp;gt; &lt;br /&gt;
PET/CT ROI Project. Initial design specs discussion with end-users and co-developers&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure&lt;br /&gt;
Verification of segmentation workflow GUI: from registering new case to reviewing results&amp;lt;br&amp;gt;&lt;br /&gt;
Cross study test of segmentation workflow: MGH/MS Center data - success,  HIV Project data - some EM Segmentation scene tuning is needed &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*&lt;br /&gt;
* April 2, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. Segmentation workflow completed&amp;lt;br&amp;gt;&lt;br /&gt;
* Coming Week plans:&amp;lt;br&amp;gt;&lt;br /&gt;
- Document Segmentation Workflow. Follow up with end users &amp;lt;br&amp;gt;&lt;br /&gt;
- Start with Cortical Thickness and ROI-in-longitudinal studies workflows&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* March 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All essential processing and workflow interaction clients are ready.&amp;lt;br&amp;gt;&lt;br /&gt;
- Completed segmentation for 10 out of 50 patients. The remaining cases will be finalized upon manual lesion segmentation and QC verification of WM/GM/CSF and Deep GM segmentation's. &amp;lt;br&amp;gt;&lt;br /&gt;
- TODO next week: refine QC GUI and data tracking / progress monitoring schema. &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&amp;lt;br&amp;gt;&lt;br /&gt;
- New Slicer3 web services added: re-slicing with reference image volume, casting image scalar type &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
* March 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Segmentation maps Merging Services for GM/WM/CSF (Slicer EM Segemnter), Lesion (Slicer, Manual), and Deep GM (FreeSurfer)  &amp;lt;br&amp;gt;&lt;br /&gt;
- Deep GM segmentation pipeline adopted as optional service for Social Cognition Study (22 out of 50 cases processed) &amp;lt;br&amp;gt;&lt;br /&gt;
- (In progress) GUI client for Launching Segmentation results merging with optional Deep GM segmentation with FreeSurfer &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- Complete GUI Client for Segmentation result merging &amp;lt;br&amp;gt;&lt;br /&gt;
- Progress Monitoring services for entire Study processing: EM Segmenter Preprocessing, EM Segmentation, Lesion Segmentation (including human activities assignments), Deep GM segmentation, and results consolidation. &amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* March 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All 50 cases went through &amp;quot;basic&amp;quot; One-channel EM segmentation (GM/WM/CSF) &amp;lt;br&amp;gt;&lt;br /&gt;
- Basic pipeline start-up command line client created: user has two options - request brainmask extraction or provide with previously extracted brainmask for a given subject &amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison of GM/WN/CSF performed for Slicer EM Segmenter and FreeSurfer recon-all (used with default settings). &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmenter provides more accurate output &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmentation pipeline runs faster (40 minutes vs 12 hrs when no brainmask extraction requested) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO:&amp;lt;br&amp;gt;&lt;br /&gt;
- merging modules for automatic 1-channel EM segmentation and manual lesion segmentation &amp;lt;br&amp;gt;&lt;br /&gt;
- Emerge Cortical Thickness pipeline project: use NAC ARCTIC processing steps and modules &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Selected stable EM Segmentation scenario: White Matter, Gray Matter, and Cerebrospinal Fluid &amp;lt;br&amp;gt;&lt;br /&gt;
- First 16 cases are segmented for selected scenario. Nine more cases are preprocessed for EM Segmentation.&amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison to segmentation with FreeSurfer showed better accuracy for Slicer2 EMSegmenter &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure &amp;lt;br&amp;gt;&lt;br /&gt;
- Three prerpcocessed cases failed during volume ICC masking with in-house build utility. Evaluated switching to Slicer3 Mask and island removing modules.&amp;lt;br&amp;gt;&lt;br /&gt;
- Initial design specs discussion for cortical thickness measurement pipeline. ARCTIC pipeline selected. ARCTIC preprocessing steps signifficantly overlap with EM Segmentation preprocessing workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
  &lt;br /&gt;
* February 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: &amp;lt;br&amp;gt;&lt;br /&gt;
A) parameters tuning for EM Segmenter itself (work with EM Segmenter developer), template scenes creation &amp;lt;br&amp;gt;&lt;br /&gt;
B) update preprocessing pipeline - deep gray matter atlases included &amp;lt;br&amp;gt;&lt;br /&gt;
C) test and debug preprocesing pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
D) identified missing modules: atlas autocalibration for EM Segmentation scene, Island removal for ICC mask&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- Review currently deployed modules. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: reviewed firts seven subjects' outputs, added volume orientation module into pipeline (prevents ICBM atlas linear registration failures)&amp;lt;br&amp;gt;&lt;br /&gt;
- Fused ICC(brainmask) extraction module with EM Segmenter preprocessing. Three scenarious implemented: start with pre-extracted ICC mask (longitudinal studies case), run with ICC ectration, run with ICC extraction AND ICC correction before ICBM atlas preporcessing. &amp;lt;br&amp;gt;&lt;br /&gt;
- Completion of Human activities GUI (QC, ICC Correction) planned for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: Volume Orientation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: automated preprocessing pipeline for Slicer2 EM Segmenter test version deployed. Seven cases pre-processed.&lt;br /&gt;
- PET Quantitative measurements: Preliminary design specs discussion.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: BSplineRegistration (for non-linear registration), ResampleVolume2 (for atlases resampling based on image atlase templates registration). Local and Network runs are implemented, Cluster/GridWizard implementation pending.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Slicer EM Segmenter module: preprocessing design for Slicer2 EM Segmenter&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Adapting for Slicer2 EM Segmenter (mostly from pipelines and services for previous projects)&lt;br /&gt;
  -- Integration with FreeSurfer modules for bisafield correction, brainmask extraction, and linear registration of ICBM atlases&lt;br /&gt;
  -- Preprocessing updates for non-linear registration of ICBM atlases with Slicer2 (image re-orientation service designed)&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 29, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- EM Segmentaton pipeline: preprocessing results are being transferred to XNat (anonymized data, Central XNat) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Slicer EM Segmenter module: discussed agenda and scheduled a work meeting for Social Cognition Study image segmentation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Testing stage, 95% completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- SPL XNat server: verified data exchange via RESTfull web services.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 22, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Follow up with White Matter Lesion Segmenter and Scull Stripping Modules developers: Work in Progress&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Work in Progress, 60%+ completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Discussed SPINE image repository migration to XNat&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 15, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. &lt;br /&gt;
- Social Cognition Study: &lt;br /&gt;
Work-in-progress on intermediate (reconstruction) and results (resources) data storage at XNat.&lt;br /&gt;
&amp;lt;br&amp;gt;Reviewing and preparation more cases for EM Segmentor (Slicer 3.5) tuning.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* NA-MIC Project Week&lt;br /&gt;
Selecting candidate Slicer modules for other than Lesion EM Segmentation topics of Social Cognition study: Withe Matter Lesion Segmenter (UNC), Scull Stripping utility from UIOWA.&lt;br /&gt;
Reviewing issues of currently used Scull Stripping Slicer Extension and Slicer 3.5 EM Segmenter.&lt;br /&gt;
&amp;lt;br&amp;gt;XNat Data organizing training&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 1, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Preparation of Demo for NA-MIC work week: &lt;br /&gt;
- COPD Study. Added Remote pipepline start interface (represents real world scenario where Xnat repository, Processing modules and User are at different sites)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
- EM Segmentation. Added human activities steps to the workflow: ICC (brainmask) correction and EM Segmantation scena load per se.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 25, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Pilot workflow pipeline for EM Segmentation (all steps except user-activity step: ICC correction assignment and tracking)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 18, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Build and tested web services for EM Segmentation image preprocessing: DICOM-to-NRRD conversion, registration, skull stripping, image masking.&lt;br /&gt;
Started building workflow pipeline (subject to finish first version next week)&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Started Collecting Library of Slicer Build number vs. functional modules and extensions.&lt;br /&gt;
Plan for NAMIC project week: scheduled meetings for XNat data customization, Skull-stripping modules tuning, identified Social Cognition study cases that fail EM Segmentation processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 11, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Updating and verification of EM Segmentation Scenario&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Projects:ARRA:SlicerWF:UseCaseScenarios#Usecase_MS_lesion_Assessment&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Familiarizing with Slicer3.4/5 Modules required for implementation of EM Segmentation Scenario. Participation in debugging and/or usage tuning of Dicom Conversion, Registration, Skull Stripping, Masking, and Image Casting modules. &lt;br /&gt;
&lt;br /&gt;
* December 4, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Slicer3.4's EM Segmentation and Visual QC as part of image processing pipeline for Social Cognition Study for MS Patients.&lt;br /&gt;
Project emerged. EM Segmentation template creation debugged.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
Emphysema Measurements (COPD Study) - workflow stability and scalability test.&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 27, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Emphysema Measurements (COPD Study).&lt;br /&gt;
Added compensation for long running calculations and time-outs to the main computing pipeline.&lt;br /&gt;
Visual QC (work in progress)&lt;br /&gt;
** Infrastructure&lt;br /&gt;
XNat data structure customization, metadata storage, results consolidation: new feature request list creation (work in progress)&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 13, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
*** Pilot system for whole processing cycle for Emphysema Measurements (COPD Study) including the following:&lt;br /&gt;
Web query for CT session file list download&lt;br /&gt;
Pilot user interface for submitting the file list and starting processing pipeline&lt;br /&gt;
Notification about processing steps and failures&lt;br /&gt;
Upload results to XNat repository (at this stage results are uploaded into same folder where original scans are(*))&lt;br /&gt;
*** Immediate Plans&lt;br /&gt;
Complete Visual QC module&lt;br /&gt;
Design and implement meta-data transfer to XNat (including processing details and MRML files for loading images into the 3D Slicer)&lt;br /&gt;
&lt;br /&gt;
(*)Customization of results storage&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 6, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Tuned and debugged multiple subjects processing for: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat.&lt;br /&gt;
***Started working on quality control embedding into the above scenario. Plan to complete and video-record demo next week.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***Published general Product Integration scenario flow chart to collaborators' community. Discussion is open and in progress&lt;br /&gt;
&lt;br /&gt;
* October 30, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Piloted and tested the sequence: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat(1).&lt;br /&gt;
***Performance test of overall cycle: data transfer from remote serve is a bottleneck as expected&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data browsing features reviewed.&lt;br /&gt;
(1) Not automated yet&lt;br /&gt;
* October 23, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Defined COPD processing scenario with interoperability between Xnat, 3D Slicer Command Modules, Workflow, and Gridwizard Enterprise.&lt;br /&gt;
***Pilot version of Emphysema Measurements workflow pipeline deployed.&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data transfer features reviewed. Use account at XNat Central during learning curve.&lt;br /&gt;
***Feasibility test of 3D Slicer fiducials module for ROI highlights during QC and manual image processing activities. &lt;br /&gt;
* October 16, 2009&lt;br /&gt;
**Lung CT Scans Processing. Pilot project emerged. GenerateEmphysemaMeasurements module deployed as a webservice that submits jobs to computational cluster.&lt;br /&gt;
**EM Segmentation. Familiarized with GUI steps. Started working on automation steps outlining&lt;br /&gt;
**3D Slicer and XNat interaction. Got an overview from Wendy Plesniak.&lt;br /&gt;
* October 1 - 7, 2009&lt;br /&gt;
**Selected two first priority Projects: EM Segmentation of brain MRI images; Lung CT Scans Processing (COPD Study)&lt;br /&gt;
**Got initial outline of user requirements and design specs&lt;/div&gt;</summary>
		<author><name>Azaitsev</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=66839</id>
		<title>Projects:ARRA:SlicerWF</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=Projects:ARRA:SlicerWF&amp;diff=66839"/>
		<updated>2011-04-25T13:06:41Z</updated>

		<summary type="html">&lt;p&gt;Azaitsev: /* Progress */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Projects:ARRASuplements|Back to Slicer ARRA home page]]&lt;br /&gt;
= Aim =&lt;br /&gt;
Supplement 3D Slicer and Extensible Neuroimaging Archive Toolkit (XNAT) with workflow management system. Provide integration and interoperability between 3D Slicer, XNAT Services and 3-rd party image processing applications and high performance computing systems. Implement it as within currently developed Structural Planning and Implementation in Neurological Exploration (SPINE) System.&lt;br /&gt;
&lt;br /&gt;
= SPINE Project Documentation =&lt;br /&gt;
[http://cni.bwh.harvard.edu/projects/spine/index.html SPINE Docs]&lt;br /&gt;
&lt;br /&gt;
= Presentations =&lt;br /&gt;
* Segmentation Workflow. PECS University Social Cognition Study.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:SlicerWF_NAC_PECS_Workflow.pdf]]&lt;br /&gt;
* EAB10_ARRA Annual Progress Report Slides.&amp;lt;br&amp;gt;&lt;br /&gt;
[[media:EAB10_ARRA_WF_2011_Zaitsev.ppt | Service Oriented Solutions for 3D Slicer. EAB10_ARRA_WF_2011. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:EAB10_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:NAMIC_ARRA_WF_2011_Zaitsev.ppt  | NAMIC Annual Report 04/2010-03/2011. NAMIC_ARRA_WF_2011_Zaitsev. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:NAMIC_ARRA_WF_2011_Zaitsev.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[media:Slicer_WF_Slicer4CARMAWorkflow.ppt  | CARMA Workflow. Cardiac Ablation Followup. PPT]] &amp;lt;br&amp;gt;&lt;br /&gt;
File location: [[File:Slicer_WF_Slicer4CARMAWorkflow.ppt]] &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
= All Hands Meeting Pages =&lt;br /&gt;
* Salt Lake City 2011 Winter [http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA SLC_2011_WorkFlow]&lt;br /&gt;
* MIT 2010 Summer [http://wiki.na-mic.org/Wiki/index.php/Summer_project_week_2010_Workflows_SOA MIT_2010_WorkFlow]&lt;br /&gt;
&lt;br /&gt;
= Research Plan =&lt;br /&gt;
*Create a stand-alone SPINE desktop agent with fully functional data exchange and communication mechanisms towards 3D Slicer and XNAT.&lt;br /&gt;
*Develop Service Oriented Architecture (SOA) SPINE System that will include 3D Slicer image processing modules deployed as web services as well as a workflow management system to orchestrate interaction between 3D Slicer, XNAT, and 3-rd party tools.&lt;br /&gt;
*Implement two-way control and communications between 3D Slicer and SPINE modules.&lt;br /&gt;
*Adapt SPINE System for cluster and grid computing scenarios.&lt;br /&gt;
*Provide with workflow and 3D Slicer web service wrappers editing tools.&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:UseCaseScenarios| Use Case scenarios]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PETCTWorkflow| PETCTWorkflow]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:AgingStudySegmentation| AgingStudySegmentation]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:TwoTensorTractography| TwoTensorTractography]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:LongitudinalMultimodalityRegistrationSuite| LongitudinalMultimodalityRegistrationSuite]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:MigrationJavaClients2QT| MigrationJavaClients2QT]]&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:PediatricMSSegmentation| PediatricMSSegmentation]]&lt;br /&gt;
*[[DBP3:Utah:RegSegPipeline| MRI-based study and treatment of atrial fibrillation]]&lt;br /&gt;
&lt;br /&gt;
= Application Server / Workflow Engine Downloads =&lt;br /&gt;
*[[Projects:ARRA:SlicerWF:WFEngineDownloads| Download Links]]&lt;br /&gt;
&lt;br /&gt;
=Key Personnel=&lt;br /&gt;
* Charles Gutmann, MD., 4%,  9-17-2009 through 9-16-2011&lt;br /&gt;
* Alexander Zaitsev, Ph.D., 75%, 9-17-2009 through 9-16-2011 &lt;br /&gt;
&lt;br /&gt;
=Annual Progress Statements =&lt;br /&gt;
'''2010-11''' &amp;lt;br&amp;gt;&lt;br /&gt;
The  April 2011 – March 2011 period was devoted on developing portable workflow solutions that can be deployed on end-users' workstations or notebooks with minimal or no system administration activities. This is in contrast to the server-side deployment. The following scenarios had been deployed and used for actual projects that require the following types of workflows: PET/CT registration and computation of biomarker driven brain physiological activities, Brain MRI Images segmentation,  MRI and MRI Angiography images pre-processing for cardiac ablation outcome estimation. Some  workflows (like EM Segmentation) had been utilizing various scenarios, some research projects  (like evaluation of chemotherapy outcome) require two types of workflows to assess physiological and structural changes. Starting from the 4th Quarter of 2011, the migration project had been emerged in order to embed Workflow GUIs into newly developed Slicer4 Suite. The existing rich client Java GUI applications are being re-written as C++/QT Sliceletts units, new modules (such as cardiac ablation project support) are had been written from scratch. The latter are being deployed from the Slicer4 GUI and act at a liaison between Slicer4 and Application Server containing  workflow and Slicer modules deployed as services. The feedback from the end users indicates that Workflow approach for the complex processing improves productivity, aids to the processing standardization and contributes to the overall experience using 3D Slicer&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
=Quarterly Progress=&lt;br /&gt;
&lt;br /&gt;
* NAMIC Annual Progress Slides (April 2010 - March 2011):&lt;br /&gt;
&lt;br /&gt;
* '''1st Qtr, 2011''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study: Second release is under testing by end-users. &lt;br /&gt;
*** Added MRI registration to aid ROI drawing on PET scans&lt;br /&gt;
*** Improved SUV results reporting and added flexibility to update ROI lookup table&lt;br /&gt;
*** Automated EM Segmentation of MRI images for computing SUVs for white matter, CSF, and whole brain (80% completion)&lt;br /&gt;
*** Integration with SPECTRE scull stripping module (70% completion) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** EM Segmentation: Automated WF Pipelines are created &amp;lt;br&amp;gt;&lt;br /&gt;
*** Flexible atlas selection (Pediatric, etc) feature added&lt;br /&gt;
*** Workflows implemented for EM Segmenter 3.6.2 and 3.6.3 (1st Qtr 2011 release)&lt;br /&gt;
&lt;br /&gt;
** Cardiac ablation results follow-up: Workflow for registration and ROI selection of cardiac MRI and MR Angiography &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Wrokflow and Web Services for prospective DTI tractography modules (currently written as Matlab modules at PNL) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
** Web Services for SPECTRE Scull stripping module&lt;br /&gt;
*** Accuracy and performance tuning&lt;br /&gt;
*** 50% completion&lt;br /&gt;
&lt;br /&gt;
** Migration Front End GUI to Slicer4/QT:&lt;br /&gt;
*** EM Segmentation&lt;br /&gt;
*** Cardiac Ablation Study&lt;br /&gt;
&lt;br /&gt;
** DICOM Uploader and Desktop Browser for XNat Image repository (alpha version - tested for MGH MS Center studies, proposed to use with MI2B2 Clients and Services)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''4th Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** PET/CT Longitudinal Study and EM Segmentation for Aging Study are deployed at end-user sites and actively used for research. &lt;br /&gt;
** Adopted EM Segmentation preprocessing pipeline for HIV Study: high resolution SPGR images, integration with FreeSurfer brainmask extraction outputs; integration of Slicer SPECTRE module for brainmask extraction is in progress.&lt;br /&gt;
** The following post-release upgrades had been implemented based on end-user feedback: Application Server basic controls are performed from Rich Client GUI as alternative to traditional IT administration activities. The controls are implemented on point-and-click bases and include web services and workflow application deployment and upgrades, application server start and stop as well as warning end user when the server is not accepting request.&lt;br /&gt;
** Added DICOM downloads and results uploads of PET/CT pipelines from and to XNat Repository&lt;br /&gt;
** Created Services and Workflow for Matlab Prototypes modules. Case Study: tractography for DTI images&lt;br /&gt;
** Extended XNAT integration services:&lt;br /&gt;
*** Browsing capabilities of XNat data repository from the Workflow Applications&lt;br /&gt;
*** Improved DICOM upload and download performance&lt;br /&gt;
*** Added Metadata organizing services for uploaded DICOM images: header data extraction, image snapshots creation. &lt;br /&gt;
** Started project for Rich Client GUI migration from Java desktop application to build into SLicer4 QT modules. This affects mostly front-end GUI and has the following approaches: distribution with the Slicer4, end-user will select desired workflow application from Slicer4 menu while QT-written modules provide with the same functionality as Java Rich Clients. Case Study for the Migration process: registration suite for longitudinal studies that include multi-modality images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* '''3d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Concentrated on building downloadable workflow applications that could run both in desktop (new) and server environment, and that require minimum IT administrative resources. The desktop deployment is in compliance with Slicer3 general deployment concept.&lt;br /&gt;
*** The following use case scenario had been chosen: PET/CT image processing for longitudinal studies, EM Segmentation for longitudinal Aging Study.&lt;br /&gt;
** Released workflow application for PET/CT image processing for longitudinal studies. Provided end users with training and documentation.&lt;br /&gt;
*** The PET/CT processing workflow was designed to be a general application used whenever both structural patterns and metabolic activities are within the research scope. &lt;br /&gt;
*** The desktop version is tuned to use minimal computer resources, so the automates processing instances do not interfere with human activities. Automated activities may include, for example, registration and PET scan's standard uptake values computing, and manual human activities may include image cropping, quality control, and labeling voxels of interest.&lt;br /&gt;
** Core services and EM Segmentation preprocessing workflow was build for retrospective Aging Study. Tuned the Slicer3 webservices for processing low grade images acquired in mid 90s. Entire workflow is implemented with Slicer3 only modules and can be deployed locally and on the servers. Usage of Service Oriented Architecture (SOA) as a core technological approach allowed reusing most of the web services that had been build for PET/CT project. &lt;br /&gt;
** Continued embedding Slicer3 application and modules into previously released processing pipelines: replaced MIPAV with Slicer3 GUI for lesion assessment step in the multi-center Pediatric MS Cohort image processing &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* '''2d Qtr, 2010''' &amp;lt;br&amp;gt;&lt;br /&gt;
** Completed Social Cognition Workflow Implementation. This includes EM Segmetnation pre- and post-processing pipelines, data tracking, and integration with 3d party image processing utilities, as well as processing results acquired manually with Slicer GUI.  &lt;br /&gt;
** Multi-modality image registration and ROI selection/alignment workflow for longitudinal studies. &lt;br /&gt;
*** Use case: PET/CT image processing for longitudinal studies. &lt;br /&gt;
*** Build portable library of Slicer modules as web services and workflow that are deployed and run on a end-users' worksatations without utilization of SPL and other servers. The web services include novel Slicer3 modules, such as BRAINSFit and BRAINSResamle &lt;br /&gt;
*** Started working with Slicer3 developers on Slicer 3.8 GUI wizard to communicate with workflow instances.&lt;br /&gt;
** Participated at NA-MIC Summer 2010 Project Week: [[Summer_project_week_2010_Workflows_SOA]]&lt;br /&gt;
&lt;br /&gt;
=Progress=&lt;br /&gt;
* April 15, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Beta release ready. Demo Location: http://cni29.bwh.harvard.edu/SlicerWFDemo/index.php&lt;br /&gt;
* TODO: Tutorial. Original inputs copy/renaming&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 15, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Adding App server auto-config features&lt;br /&gt;
* Finalizing the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 08, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Second release beta build tested on cosutmer side &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Review registration quality (with Dr. Meier). Angiography images' Resampling tuned. &lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 01, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the second release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
CARMA Project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized the feature set&lt;br /&gt;
* Work on the beta release &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
XNat Integration&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* (Java) GUI for Project Browsing and DICOM Series Upload. Post-upload DICOM processing tested and debugged&amp;lt;br&amp;gt;&lt;br /&gt;
* Ready for integration with mi2b2 client.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Migrated to Latest Slicer 3.6.3 stable release: only the Input scene had to be updated, the API remained the same&lt;br /&gt;
* Tested EM Segmenter with CMTK4Slicer extension - processing takes to much time on Linux_64bit machine, rolled back to BRAINSFit registration. When used on Mac OS X build, the Slicer could not start (bug report 1126).&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SPECTRE Scull Stripping:&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Testes for various use cases: the module is extremely sensitive to T1 MRI quality (does not work for most MRIs from PET/CT project&lt;br /&gt;
* TODO next week: check for FLAIR images&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Slicer4 QT GUI and Cropping activity in progress.&amp;lt;br&amp;gt;&lt;br /&gt;
* Tried direct MRA to MRA registration option: resampling with LMRI registration transforms works better.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Extra VOI labels revised&lt;br /&gt;
* Debugging of SUV results' renormalization step&lt;br /&gt;
* TODO: ICC extraction / whole brain total uptake computing; EM Segmentation for R_WM, L_WM SUV computing and BPH estimation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
SCULL STRIPPING/SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Installed and tested CLI option on Linux_64bit platform&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Workflow interruption before BSPline registraton: BPEL Module completed. Slicer4 QT GUI and Cropping activity in prorgess.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Implemented and Tested with end-users proposed changes: denormalization of SUV results, adding more VOI labels, added FLAIR MRI in addition to T1s for VOI drawing&lt;br /&gt;
* Tested manual ICC extraction using PET scans: works satisfactory with island removal and cropping followed by threshold level labeling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4&lt;br /&gt;
* Change proposed: interrupt workflow after affine registration and have user crop the VOI. This is to prevent excessive deformations for BSpline registration and resampling&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT / EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Front-end GUI incorporated into Slicer4. User has option to choose the atlas that fits better for the given subject (NOTE: hardcoding must be rewritten for atlas linking)&lt;br /&gt;
* PETCT test - the problem is that T1s are low resolution and with contrast. Proposed using T1s without contrast&lt;br /&gt;
* PETCT change request: users wants to compute SUV for entire ICC. Had demo how to segment brainmask/ICC using PET scan. The derived brainmask label can be used for SUV computation.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 25, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - cmpleted&lt;br /&gt;
* Sample cases run - excessive deformation after BSpline registration hase&lt;br /&gt;
* Next week plan - pull tuning controls to front-end of pipeline API, start working of QT module for CARMA registration&lt;br /&gt;
* May consider other than BRAINSFit registration modules&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Design plan for change request: more VOI labels, add FLAIR in addition to T1 for VOI drawing, T1s segmentation&lt;br /&gt;
* Tested segmentation for sample cases - artifacts from poor quality MRIs lead to exclusion of parts of ICC from segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
EM Segmentation&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Completed troubleshooting of EMSegmenter module calling from Java (need TCL libs to be pulled from Slicer environment)&lt;br /&gt;
* Tested EMSegmenter autoruns for HIV and Pediatric MS patiens. Work as expected, subject to improvement of PED MS case segmentation by building better skull/neck/air atalses&lt;br /&gt;
* Suggested usage of two subsets of atalases: with and without neck. The Subject MRIs have to be cropped accordingly or best fit atlas has to be selected&lt;br /&gt;
* Made no-neck cropped atlas collection for default EMSegmenter scenario&lt;br /&gt;
* Tested with PET/CT study MRI cases - see above &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* February 18, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
CARMA DBP&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* BPEL pipeline coding - in progress&lt;br /&gt;
* Next week goal - have back end processing ready&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PETCT Longitudinal Study&lt;br /&gt;
* Added MRI registration to the pipeline&lt;br /&gt;
* Troubleshooting of complex XML schema issues on Linux machines (some modules working on MAC do not work on Linux). As a workaround - did not include MRI convert and register part into base BPEL module. Used separate services (transparent for end-user)&lt;br /&gt;
* TODO next week for change request completion: explicit pixel type casting for MRI in BRAINSFit, VOI MRML scene update (currently MRI added on top of schema)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* February 11, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipeline for Pediatric MRI. Same scenario as for HIV Project, icbm pediatric atlases (Completed, verified)&lt;br /&gt;
* Collected NIH healthy brain development atlases: various age ranges from 4.5 to 18 yo. Converted to Slicer readable format &lt;br /&gt;
* Work on web services for the new automated EM Segmenter module (release Nov 10 - current). Verified task completion both for adult and pediatric images. Discussed tuning parameters for work load balance on workstations.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Started working on MRI registration to the reference CT scans. &lt;br /&gt;
* Design specs for optional White Matter segmentation for SUV computing.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* February 4, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmenter&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* Porting existing pipelines for Pediatric MRI (in progress)&lt;br /&gt;
* Adapting Pediatric T1 atlases for &amp;quot;Human Brain&amp;quot; build-in EM Segmentation wizard (in progress)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 28, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Verifying EM Segmenter module for latest builds and HIV/PED MS Studies (report pending)&lt;br /&gt;
* Work with SPECTRE module developers with pediatric MRI brainmask extraction&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* January 21, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Compiling plan for WF FrontEnd GUI migration to Slicer4/QT Widgets&lt;br /&gt;
* Preparing for annual progress report&lt;br /&gt;
&lt;br /&gt;
* January 14, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI: Integrated into the Slicer4 as Slicelet (or thin Client)&lt;br /&gt;
* Participation at AHM-2011, discussing integration of SPECTRE module and updated approach to EM-Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Winter_project_week_2011_Workflows_SOA&lt;br /&gt;
&lt;br /&gt;
* January 7, 2011 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* HIV project workflow delivered. Major additions relate to user convenience: &lt;br /&gt;
- Project-specific parameter settings, importing T1s and brainmasks from FreeSurfer outputs with conversion to NIFTI, resampling brainmask to original scans and automatied subject addition.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* QT Widget for basic EM Segmentation Workflow GUI&lt;br /&gt;
&lt;br /&gt;
PETCT Longitudinal Study:&lt;br /&gt;
* Follow up with end user: need to add MRI scans, if available, addition and registration to CT in order to ease VOI drawings.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
 &lt;br /&gt;
* December 31, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Follow-up with user Experience for AGING Study Segmentation (Positive feedback)&lt;br /&gt;
* Target date for HIV project delivery - next week&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Self-training for QT widget development&amp;lt;br&amp;gt;&lt;br /&gt;
* Outlined Workflow Rich Clients migration strategy from Java to QT/Slicer4:&amp;lt;br&amp;gt;&lt;br /&gt;
** Use Java Stubs (similar to SPECTRE integration) or file binding for envocation of workflow pipelines. (See SOAP remark below)&lt;br /&gt;
** Direct Web Servisec calls must be wrapped into REST protocol. The reason: NON-commerchial QT kit does not include SOAP protocol for web servises.&lt;br /&gt;
** The GUI will be implemented as page widget or QT dialog GUI forms called from within Slicer4.&lt;br /&gt;
** Communications between Slicer4 and WF GUI will be set via child-parent and signal-slot relations&lt;br /&gt;
* Worked on a Prototype for Basic EM Segmentation QT widget (70% complete). Will work on integrtion with SLicer4 during the AHM-2010&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
XNAT Integration&lt;br /&gt;
* Debugged XNAT RESTFul API usage for uplaoding DICOM series followed by header data extraction and image snapshots creation&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY / HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Added compensation for failed atlas registration (subject for old poor quality pseudo-T1 images): blank probability maps are created in case of failure.&lt;br /&gt;
* Data preparation module for FreeSurfer data import near completion. Expected time for deployment at end-users workstations - first week of January&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT:&lt;br /&gt;
* Discussed strategy for EM Segmentation pipeline solutions collection (K. Pohl, R. Kikinis)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* December 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
HIV STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* RE-using the same core workflow as for 1-channel EM Segmentation of AGING STUDY cases&lt;br /&gt;
* Added data input preparation module: ICC label mask preparation and skull-stripping based on FreeSurfer brainmask output volume.&lt;br /&gt;
* Two-channel EM segmentation pipeline (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE / GENERAL Development &amp;lt;br&amp;gt;&lt;br /&gt;
* Worked on plans for migrating fro rich workflow Java clients to embedded workflow windows inside the Slicer.&amp;lt;br&amp;gt;&lt;br /&gt;
The embedded workflow management clients are to be implemented with QT/PyQT toolkits&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
INTEGRATION WITH XNAT:&amp;lt;br&amp;gt;&lt;br /&gt;
* Automated DICOM series upload with triggering DICOM headers parsing at XNat site (in-progress)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress. &lt;br /&gt;
- Results upload to XNat (Completed) &amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat based on user's input (Project + Subject + PET or CT session / scan) (Completed)&amp;lt;br&amp;gt;&lt;br /&gt;
- DICOM Downloads from XNat - perfomance boosting solution for downloads found , web services services are created, relinking for the client side in progress &amp;lt;br&amp;gt;&lt;br /&gt;
- Xnat querying for subjects and automated subject addition into the workflow (In Progress) &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-segmentation module added for auto correction of segmentation results. Particularly - relabeling CSF voxels segmented as Air inside the intracranial cavity. This was requested by end-users after processing images with zero-signals in CSF voxels &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting automated dual-echo DICOM images conversion and split into two NRRD volumes&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL DEVELOPMENT / EM Segmentation pipeline:&amp;lt;br&amp;gt;&lt;br /&gt;
* Troubleshooting memory allocation issues for scull-stripping module SPECTRE&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
COPD Project:&amp;lt;br&amp;gt;&lt;br /&gt;
* Benchmark test for accelerated DICOM downloads from XNat (remoote XNat Central server): we can handle at least 6 cases (4 CT scans in each) per hour, which is compatible with current workload quotes on SPL cluster processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* December 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Integration with XNat - work in progress&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Deployed Version 1. &amp;lt;br&amp;gt;&lt;br /&gt;
REGISTRATION SUITE&amp;lt;br&amp;gt;&lt;br /&gt;
* Test project chosen as a closest match to registration scenario: Pediatric MS Cases from MGH - requires periodic image preview for different &lt;br /&gt;
modalities taken from vaious time points. Label maps for VOIs resampling is also required.&lt;br /&gt;
&lt;br /&gt;
* November 26, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user. Version 1 is complete&amp;lt;br&amp;gt;&lt;br /&gt;
* Started working on integration with XNat&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on input data organizing modules&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 19, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package and minimization of administrative load for end-user (70% done)&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Universal Registration Workflow for Longitudinal Studies - design specs in progress&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 12, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Minor tuning to EM Segmentation template as of users' feedback&lt;br /&gt;
* Users started using the workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed input data conversion from Genesis to Slicer native or NIFTI format. Our help may be needed in input data organizing.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Tuned application according to co-laborators (PNL) needs&amp;lt;br&amp;gt;&lt;br /&gt;
* The webservices and BPEL workflow application are tested ready to accept computation requests from PNL case tracking system &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT Registration and ROI workflow&amp;lt;br&amp;gt;&lt;br /&gt;
* Work on distribution/installation package&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
General Development&lt;br /&gt;
* Discussed Universal Registration Workflow for Longitudinal Studies&lt;br /&gt;
* Started the thread about possible cooperation with Children hospital's image processing pipelines and integration with Xnat &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 5, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Webservices and workflow pilot project created and deployed on Psychiatry Neuroimaging Laboratory subnet &amp;lt;br&amp;gt;&lt;br /&gt;
* The V.1.0 deployment is scheduled for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 29, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Most of functionality is completed. Some volume statistics post processing is pending&amp;lt;br&amp;gt;&lt;br /&gt;
GENERAL EM SEGMENTATION Pipeline: &amp;lt;br&amp;gt;&lt;br /&gt;
* The SPECTRE scull stripping module. Started integration into EMS workflow. Made some test runs from Slicer GUI&amp;lt;br&amp;gt;&lt;br /&gt;
TWO-TENSOR TRACTOGRAPHY&amp;lt;br&amp;gt;&lt;br /&gt;
* Identified as a candidate for Workflow Application&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 22, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* All back-end functionality are implemented&amp;lt;br&amp;gt;&lt;br /&gt;
* EM Segmentation scene usability is confirmed by end-user&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for next week: add Label Statistics computation for CSF/Brain/ICC &amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 15, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* The latest (October) builds of Slicer 3.6.2 produced acceptable results. This was verified by the target users. The EM Segmentation will be performed on Slicer 3.6.2 or later&amp;lt;br&amp;gt;&lt;br /&gt;
* The new Web services had been created and added to the pipeline as optional processing steps: Biasfield correction (implement novel N2ITKBiasFieldCorrection module) and Volume's scalar datatype casting (as workaround for Biasfield correction module not preserving image scalar datatype - the bug is filed) &amp;lt;br&amp;gt;&lt;br /&gt;
* Discussed the Front-End GUI design with target users. The design pattern is taken from the PETCT project&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 8, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Post-deployment support. Tuned CT registration as of user's feedback.&lt;br /&gt;
* Adapting to the Single Slicer build: Slicer 3.6.2. Found label duplicates in the label lookup table - will ask user if it's tolerable. Waiting for the Slicer 3.6.2 build that contains all required modules. Rolling back label tag appending code for SUVs - the latest Slicer build appends the tags.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Resumed development. The priorities are set for usage of Slicer 3.6.2 - subject for EM Segmentation scene tuning. Continued coding for Scene creation for Slicer 2.8 - as a backup option for ongoing research project.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* October 1, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Finalized V1.0 release based on end-user feedback: updates relate mostly to error proofing and SUV values representation&lt;br /&gt;
* Post-deployment support. Users pre-processed first set of patients &lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* September 24, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* System deployed and tested at End Users' site.&amp;lt;br&amp;gt;Users are trained to perform all tasks required by the workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
* Got positive feedback with suggestions on Slicer Scenes' layouts improvement and PET scans' SUV (standard uptake values) results display&lt;br /&gt;
* Two distribution packages are assembled: Lunix and MAC OS versions. The difference in two packages is in specific Slicer3.6/3.7 builds - subject to Slicer Linux builds debugging.&amp;lt;br&amp;gt; As a workaround for Linux deployment - multiple Slicer builds are used to perform various tasks (registration, opening editing scenes in Slicer, SUV computing)&amp;lt;br&amp;gt;&lt;br /&gt;
* Plans for coming week - finalize V1.0 release based on end-user feedback&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 17, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
* Embedded SUV computations into the workflow (as system calls - will be translated into web service later)&amp;lt;br&amp;gt;&lt;br /&gt;
* Pre-release demo for end users.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* September 10, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Create and debug EM Segmenter scenes template for Slicer 3.6 and 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* September 3, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation - workflow pipeline and deployment verified&amp;lt;br&amp;gt;&lt;br /&gt;
* Tested EM Segmentation scenes within Slicer 2.8 &amp;lt;br&amp;gt;&lt;br /&gt;
* Started migration of EM Segmentation to Slicer 3.6. Discovered issues had been reported to EM Segmenter module designers &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* August 29 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
* Preprocessing webservices for EM Segmentation completed. Preprocessing Pipleine completed 80% (subject for input registration parameters tuning) &amp;lt;br&amp;gt;&lt;br /&gt;
* Most webservices (for registration and resampling steps) had been taken and re-used from PET/CT ROI/Longitudinal Study - showing the advantage of service-oriented software design and deployment.&lt;br /&gt;
* Continued on distribution and deployment of the service/workflow applications: on PET/CT and AGING STUDY projects.&lt;br /&gt;
&lt;br /&gt;
PEDIATRIC Multiple Sclerosis Cohort. Support of multi-center distributed processing project&amp;lt;br&amp;gt;&lt;br /&gt;
* Introduced Slicer 3.6 for the MS Lesion Assessment step performed at Mayo Clinic. Images are being transferred from image repository at BWH and automatically opened and arranged within Slicer GUI for reading.  This was replacement of Client GUI using MIPAV that stopped working on new computers at Mayo Clinic.&lt;br /&gt;
The images are being loaded via generated MRML Scenes same way as in PET/CT and AGING STUDY projects &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* August 22 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Preprocessing pipeline merge with SUV computations &amp;lt;br&amp;gt;&lt;br /&gt;
- QA for SUVs computation was performed by Wendy Plesniak for images with known uptake values. &amp;lt;br&amp;gt;&lt;br /&gt;
- Discovered that image cropping step (not related to automated registration pipeline and SUVs computing) smoothes the images by doing interpolation when used with default settings. Got suggestions from Steve Piper using Nearest-Neighbor interpolation (&amp;quot;no interpolation&amp;quot;) for a time being&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
AGING STUDY - Retrospective Segmentation&amp;lt;br&amp;gt;&lt;br /&gt;
- This is the new project candidate. Requested for the images with failed manual segmentation and/or segmentation with FreeSurfer. The EM Segmentation run showed most acceptable results on one of the problem images back in February &amp;lt;br&amp;gt;&lt;br /&gt;
- The workflow will be developed and deployed similar to PET/CT ROI Longitudinal study approach - all preprocessing steps will be done with Slicer modules, all runs will be performed on local end-user machines.&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
 &lt;br /&gt;
&lt;br /&gt;
* August 15 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- First 5 cases with 3-4 time points preprocessed for SUVs computation&lt;br /&gt;
&lt;br /&gt;
* August 8 2010&amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Testing of installation and operation at users' site (Performed by Wendy Plesniak)&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* July 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Delivered beta version of registration pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
- Prepared installation and user manuals &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* June 11, 2010 &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study&amp;lt;br&amp;gt;&lt;br /&gt;
- Registration modules completed &amp;lt;br&amp;gt;&lt;br /&gt;
- Irregular cases registration problem solved (when whole body and brain only scans are mixed for a timepoint)&amp;lt;br&amp;gt;&lt;br /&gt;
- Live demo of case setup and registration workflow for end users. Real case with 4 timepoints used&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Coming week plans&amp;lt;br&amp;gt;&lt;br /&gt;
- Adjust workflow based on end users' feedback&amp;lt;br&amp;gt;&lt;br /&gt;
- Integration with SUVs computing for PET scans&amp;lt;br&amp;gt;&lt;br /&gt;
- GUI for workflows dispatching and data organizing&amp;lt;br&amp;gt;&lt;br /&gt;
- (TBD) Integration with 4D time series analysis Slicer module&amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
* May 28, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- Migration to the latest Slicer 3.6 release candidate &amp;lt;br&amp;gt;&lt;br /&gt;
- Added webservice for new registration module: BRAINSFit &amp;lt;br&amp;gt;&lt;br /&gt;
- Test runs for new patients with 4 timepoints' scans &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Plans for next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI &amp;lt;br&amp;gt;&lt;br /&gt;
- processing workflow demo for end user &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* May 21, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Pilot version of portable web services and automated workflow tested: &amp;lt;br&amp;gt;&lt;br /&gt;
Linux: workflow and visual review passed&amp;lt;br&amp;gt;&lt;br /&gt;
Stress test for 25 timepoints passed &amp;lt;br&amp;gt;&lt;br /&gt;
MAC OS: workflow passed, visual review failing when PET/CT images are loaded into GUI simultaneously (bug report submitted)&amp;lt;br&amp;gt;&lt;br /&gt;
Windows: need to adapt command line modules and workflow management system to sygwin environment&amp;lt;br&amp;gt;&lt;br /&gt;
Plans for next week: integrate workflow with SUVs values computing for PET/CT fusion in Slicer GUI&lt;br /&gt;
&lt;br /&gt;
* May 7, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
Selected registration and resampling modules with more precise and stable outputs. &amp;lt;br&amp;gt;&lt;br /&gt;
Started building portable web services and automated workflow &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 30, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : &amp;lt;br&amp;gt;&lt;br /&gt;
- manual walk through the processing steps: ROI cropping, registration/resampling, PET pharmaceutical DICOM data retention. &amp;lt;br&amp;gt;&lt;br /&gt;
- testing workflow and web services packages distribution to end-users' machines&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* April 23, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
PET/CT ROI/Longitudinal Study Registration : testing various registration and re-sampling algorithms (work in progress)&amp;lt;br&amp;gt;&lt;br /&gt;
EM Segmentation: as of collaborators' request, run existing EM Segmentation workflow for older low resolution pseudo-T1 images. The EM Segmentation works for those images with manual sampling. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 16, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases: &amp;lt;br&amp;gt;&lt;br /&gt;
  Social Cognition Study: started Cortical Thickness Measurement module build (bases on NA-MIC ARCTIC pipeline) &amp;lt;br&amp;gt;&lt;br /&gt;
  PET/CT ROI/Longitudinal Study Registration : Design specs, PET-to-CT images registration tests on training data. &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* April 9, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. GUI update based on end-user experience.&amp;lt;br&amp;gt;&lt;br /&gt;
User request: automated label maps' volumes calculation (Currently possible from Slicer3 GUI)&amp;lt;br&amp;gt; &lt;br /&gt;
PET/CT ROI Project. Initial design specs discussion with end-users and co-developers&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure&lt;br /&gt;
Verification of segmentation workflow GUI: from registering new case to reviewing results&amp;lt;br&amp;gt;&lt;br /&gt;
Cross study test of segmentation workflow: MGH/MS Center data - success,  HIV Project data - some EM Segmentation scene tuning is needed &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*&lt;br /&gt;
* April 2, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. Segmentation workflow completed&amp;lt;br&amp;gt;&lt;br /&gt;
* Coming Week plans:&amp;lt;br&amp;gt;&lt;br /&gt;
- Document Segmentation Workflow. Follow up with end users &amp;lt;br&amp;gt;&lt;br /&gt;
- Start with Cortical Thickness and ROI-in-longitudinal studies workflows&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* March 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All essential processing and workflow interaction clients are ready.&amp;lt;br&amp;gt;&lt;br /&gt;
- Completed segmentation for 10 out of 50 patients. The remaining cases will be finalized upon manual lesion segmentation and QC verification of WM/GM/CSF and Deep GM segmentation's. &amp;lt;br&amp;gt;&lt;br /&gt;
- TODO next week: refine QC GUI and data tracking / progress monitoring schema. &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&amp;lt;br&amp;gt;&lt;br /&gt;
- New Slicer3 web services added: re-slicing with reference image volume, casting image scalar type &amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
* March 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Segmentation maps Merging Services for GM/WM/CSF (Slicer EM Segemnter), Lesion (Slicer, Manual), and Deep GM (FreeSurfer)  &amp;lt;br&amp;gt;&lt;br /&gt;
- Deep GM segmentation pipeline adopted as optional service for Social Cognition Study (22 out of 50 cases processed) &amp;lt;br&amp;gt;&lt;br /&gt;
- (In progress) GUI client for Launching Segmentation results merging with optional Deep GM segmentation with FreeSurfer &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO next week: &amp;lt;br&amp;gt;&lt;br /&gt;
- Complete GUI Client for Segmentation result merging &amp;lt;br&amp;gt;&lt;br /&gt;
- Progress Monitoring services for entire Study processing: EM Segmenter Preprocessing, EM Segmentation, Lesion Segmentation (including human activities assignments), Deep GM segmentation, and results consolidation. &amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* March 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- All 50 cases went through &amp;quot;basic&amp;quot; One-channel EM segmentation (GM/WM/CSF) &amp;lt;br&amp;gt;&lt;br /&gt;
- Basic pipeline start-up command line client created: user has two options - request brainmask extraction or provide with previously extracted brainmask for a given subject &amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison of GM/WN/CSF performed for Slicer EM Segmenter and FreeSurfer recon-all (used with default settings). &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmenter provides more accurate output &amp;lt;br&amp;gt;&lt;br /&gt;
-- EM Segmentation pipeline runs faster (40 minutes vs 12 hrs when no brainmask extraction requested) &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
TODO:&amp;lt;br&amp;gt;&lt;br /&gt;
- merging modules for automatic 1-channel EM segmentation and manual lesion segmentation &amp;lt;br&amp;gt;&lt;br /&gt;
- Emerge Cortical Thickness pipeline project: use NAC ARCTIC processing steps and modules &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* March 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
Social Cognition Study. &amp;lt;br&amp;gt;&lt;br /&gt;
- Selected stable EM Segmentation scenario: White Matter, Gray Matter, and Cerebrospinal Fluid &amp;lt;br&amp;gt;&lt;br /&gt;
- First 16 cases are segmented for selected scenario. Nine more cases are preprocessed for EM Segmentation.&amp;lt;br&amp;gt;&lt;br /&gt;
- Comparison to segmentation with FreeSurfer showed better accuracy for Slicer2 EMSegmenter &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* Infrastructure &amp;lt;br&amp;gt;&lt;br /&gt;
- Three prerpcocessed cases failed during volume ICC masking with in-house build utility. Evaluated switching to Slicer3 Mask and island removing modules.&amp;lt;br&amp;gt;&lt;br /&gt;
- Initial design specs discussion for cortical thickness measurement pipeline. ARCTIC pipeline selected. ARCTIC preprocessing steps signifficantly overlap with EM Segmentation preprocessing workflow.&amp;lt;br&amp;gt;&lt;br /&gt;
  &lt;br /&gt;
* February 26, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: &amp;lt;br&amp;gt;&lt;br /&gt;
A) parameters tuning for EM Segmenter itself (work with EM Segmenter developer), template scenes creation &amp;lt;br&amp;gt;&lt;br /&gt;
B) update preprocessing pipeline - deep gray matter atlases included &amp;lt;br&amp;gt;&lt;br /&gt;
C) test and debug preprocesing pipeline &amp;lt;br&amp;gt;&lt;br /&gt;
D) identified missing modules: atlas autocalibration for EM Segmentation scene, Island removal for ICC mask&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- Review currently deployed modules. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 19, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
* Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: reviewed firts seven subjects' outputs, added volume orientation module into pipeline (prevents ICBM atlas linear registration failures)&amp;lt;br&amp;gt;&lt;br /&gt;
- Fused ICC(brainmask) extraction module with EM Segmenter preprocessing. Three scenarious implemented: start with pre-extracted ICC mask (longitudinal studies case), run with ICC ectration, run with ICC extraction AND ICC correction before ICBM atlas preporcessing. &amp;lt;br&amp;gt;&lt;br /&gt;
- Completion of Human activities GUI (QC, ICC Correction) planned for coming week &amp;lt;br&amp;gt;&lt;br /&gt;
* Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: Volume Orientation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 12, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Social Cognition Study. Slicer EM Segmenter module: automated preprocessing pipeline for Slicer2 EM Segmenter test version deployed. Seven cases pre-processed.&lt;br /&gt;
- PET Quantitative measurements: Preliminary design specs discussion.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- The following Slicer3.5 Modules deployed as web services: BSplineRegistration (for non-linear registration), ResampleVolume2 (for atlases resampling based on image atlase templates registration). Local and Network runs are implemented, Cluster/GridWizard implementation pending.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* February 5, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Slicer EM Segmenter module: preprocessing design for Slicer2 EM Segmenter&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Adapting for Slicer2 EM Segmenter (mostly from pipelines and services for previous projects)&lt;br /&gt;
  -- Integration with FreeSurfer modules for bisafield correction, brainmask extraction, and linear registration of ICBM atlases&lt;br /&gt;
  -- Preprocessing updates for non-linear registration of ICBM atlases with Slicer2 (image re-orientation service designed)&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 29, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- EM Segmentaton pipeline: preprocessing results are being transferred to XNat (anonymized data, Central XNat) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Slicer EM Segmenter module: discussed agenda and scheduled a work meeting for Social Cognition Study image segmentation.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Testing stage, 95% completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- SPL XNat server: verified data exchange via RESTfull web services.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 22, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases.&lt;br /&gt;
- Follow up with White Matter Lesion Segmenter and Scull Stripping Modules developers: Work in Progress&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
- Work on Web Services for structured data exchange between XNat and Workflow Instances (Work in Progress, 60%+ completion) &amp;lt;br/&amp;gt;&lt;br /&gt;
- Discussed SPINE image repository migration to XNat&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
* January 15, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. &lt;br /&gt;
- Social Cognition Study: &lt;br /&gt;
Work-in-progress on intermediate (reconstruction) and results (resources) data storage at XNat.&lt;br /&gt;
&amp;lt;br&amp;gt;Reviewing and preparation more cases for EM Segmentor (Slicer 3.5) tuning.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* NA-MIC Project Week&lt;br /&gt;
Selecting candidate Slicer modules for other than Lesion EM Segmentation topics of Social Cognition study: Withe Matter Lesion Segmenter (UNC), Scull Stripping utility from UIOWA.&lt;br /&gt;
Reviewing issues of currently used Scull Stripping Slicer Extension and Slicer 3.5 EM Segmenter.&lt;br /&gt;
&amp;lt;br&amp;gt;XNat Data organizing training&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* January 1, 2010 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Preparation of Demo for NA-MIC work week: &lt;br /&gt;
- COPD Study. Added Remote pipepline start interface (represents real world scenario where Xnat repository, Processing modules and User are at different sites)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
- EM Segmentation. Added human activities steps to the workflow: ICC (brainmask) correction and EM Segmantation scena load per se.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 25, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Pilot workflow pipeline for EM Segmentation (all steps except user-activity step: ICC correction assignment and tracking)&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 18, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Build and tested web services for EM Segmentation image preprocessing: DICOM-to-NRRD conversion, registration, skull stripping, image masking.&lt;br /&gt;
Started building workflow pipeline (subject to finish first version next week)&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Started Collecting Library of Slicer Build number vs. functional modules and extensions.&lt;br /&gt;
Plan for NAMIC project week: scheduled meetings for XNat data customization, Skull-stripping modules tuning, identified Social Cognition study cases that fail EM Segmentation processing.&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
* December 11, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Updating and verification of EM Segmentation Scenario&lt;br /&gt;
http://wiki.na-mic.org/Wiki/index.php/Projects:ARRA:SlicerWF:UseCaseScenarios#Usecase_MS_lesion_Assessment&lt;br /&gt;
** Infrastructure.&lt;br /&gt;
Familiarizing with Slicer3.4/5 Modules required for implementation of EM Segmentation Scenario. Participation in debugging and/or usage tuning of Dicom Conversion, Registration, Skull Stripping, Masking, and Image Casting modules. &lt;br /&gt;
&lt;br /&gt;
* December 4, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Slicer3.4's EM Segmentation and Visual QC as part of image processing pipeline for Social Cognition Study for MS Patients.&lt;br /&gt;
Project emerged. EM Segmentation template creation debugged.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
Emphysema Measurements (COPD Study) - workflow stability and scalability test.&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 27, 2009 &amp;lt;br/&amp;gt;&lt;br /&gt;
** Use Cases. Emphysema Measurements (COPD Study).&lt;br /&gt;
Added compensation for long running calculations and time-outs to the main computing pipeline.&lt;br /&gt;
Visual QC (work in progress)&lt;br /&gt;
** Infrastructure&lt;br /&gt;
XNat data structure customization, metadata storage, results consolidation: new feature request list creation (work in progress)&lt;br /&gt;
&amp;lt;br/&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* November 13, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
*** Pilot system for whole processing cycle for Emphysema Measurements (COPD Study) including the following:&lt;br /&gt;
Web query for CT session file list download&lt;br /&gt;
Pilot user interface for submitting the file list and starting processing pipeline&lt;br /&gt;
Notification about processing steps and failures&lt;br /&gt;
Upload results to XNat repository (at this stage results are uploaded into same folder where original scans are(*))&lt;br /&gt;
*** Immediate Plans&lt;br /&gt;
Complete Visual QC module&lt;br /&gt;
Design and implement meta-data transfer to XNat (including processing details and MRML files for loading images into the 3D Slicer)&lt;br /&gt;
&lt;br /&gt;
(*)Customization of results storage&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* November 6, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Tuned and debugged multiple subjects processing for: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat.&lt;br /&gt;
***Started working on quality control embedding into the above scenario. Plan to complete and video-record demo next week.&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***Published general Product Integration scenario flow chart to collaborators' community. Discussion is open and in progress&lt;br /&gt;
&lt;br /&gt;
* October 30, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Piloted and tested the sequence: Fetch Data From XNat - Process Emphysema Measurements - Upload Results to XNat(1).&lt;br /&gt;
***Performance test of overall cycle: data transfer from remote serve is a bottleneck as expected&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data browsing features reviewed.&lt;br /&gt;
(1) Not automated yet&lt;br /&gt;
* October 23, 2009 &amp;lt;br/&amp;gt; &lt;br /&gt;
** Use Cases&lt;br /&gt;
***Defined COPD processing scenario with interoperability between Xnat, 3D Slicer Command Modules, Workflow, and Gridwizard Enterprise.&lt;br /&gt;
***Pilot version of Emphysema Measurements workflow pipeline deployed.&amp;lt;br/&amp;gt;&lt;br /&gt;
** Infrastructure&lt;br /&gt;
***XNat customization and data transfer features reviewed. Use account at XNat Central during learning curve.&lt;br /&gt;
***Feasibility test of 3D Slicer fiducials module for ROI highlights during QC and manual image processing activities. &lt;br /&gt;
* October 16, 2009&lt;br /&gt;
**Lung CT Scans Processing. Pilot project emerged. GenerateEmphysemaMeasurements module deployed as a webservice that submits jobs to computational cluster.&lt;br /&gt;
**EM Segmentation. Familiarized with GUI steps. Started working on automation steps outlining&lt;br /&gt;
**3D Slicer and XNat interaction. Got an overview from Wendy Plesniak.&lt;br /&gt;
* October 1 - 7, 2009&lt;br /&gt;
**Selected two first priority Projects: EM Segmentation of brain MRI images; Lung CT Scans Processing (COPD Study)&lt;br /&gt;
**Got initial outline of user requirements and design specs&lt;/div&gt;</summary>
		<author><name>Azaitsev</name></author>
		
	</entry>
</feed>