<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://www.na-mic.org/w/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=Ruetz</id>
	<title>NAMIC Wiki - User contributions [en]</title>
	<link rel="self" type="application/atom+xml" href="https://www.na-mic.org/w/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=Ruetz"/>
	<link rel="alternate" type="text/html" href="https://www.na-mic.org/wiki/Special:Contributions/Ruetz"/>
	<updated>2026-05-13T11:17:11Z</updated>
	<subtitle>User contributions</subtitle>
	<generator>MediaWiki 1.33.0</generator>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=Neuroendoscope-igt&amp;diff=12518</id>
		<title>Neuroendoscope-igt</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=Neuroendoscope-igt&amp;diff=12518"/>
		<updated>2007-06-24T22:34:25Z</updated>

		<summary type="html">&lt;p&gt;Ruetz: /* functions */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;=functions=&lt;br /&gt;
# Interface&lt;br /&gt;
## '''''Generate a separate image rendering window to display captured endoscope view'''''&lt;br /&gt;
## '''''Make module with four pages'''''&lt;br /&gt;
# Display page&lt;br /&gt;
## '''''size of the windows'''''&lt;br /&gt;
## '''''show/hide them'''''&lt;br /&gt;
## changing the amount of viewable slices in DICOM Viewer&lt;br /&gt;
### option to see slices from one orientiation in a row &lt;br /&gt;
#### for example: slice 1 2 3 4 5 6 7 of an axial view (must be driveable)&lt;br /&gt;
# Registration page&lt;br /&gt;
## interfaces for ICP registration&lt;br /&gt;
### i/f to select partical surface for ICP (optional)&lt;br /&gt;
### using tracker (currently using NaviTrack, but IGSTK is preferable)&lt;br /&gt;
### i/f to give good intial guess&lt;br /&gt;
### i/f to foot switch (currently using NaviTrack, but IGSTK is preferable)&lt;br /&gt;
### re-registration function without restarting the whole procedure (previous/next steps support)&lt;br /&gt;
# Camera page&lt;br /&gt;
## Color Subframe &lt;br /&gt;
### '''''changing  color of the camera'''''&lt;br /&gt;
## Shape Subframe&lt;br /&gt;
### '''''show/hide Focal Point'''''&lt;br /&gt;
### '''''change size of the camera'''''&lt;br /&gt;
### '''''3D Gyro on/off switch'''''&lt;br /&gt;
### '''''Size changing of the Gyro'''''&lt;br /&gt;
### '''''different camera shapes'''''&lt;br /&gt;
## Probe Subframe&lt;br /&gt;
### '''''show/hide Sensor/Locator'''''&lt;br /&gt;
### '''''show/hide Probe''''' &lt;br /&gt;
### '''''show/hide guide (pointing tool (double length of Sensor/Locator)'''''&lt;br /&gt;
### '''''virtual ruler (in 0.1 cm steps) changeable by slider'''''&lt;br /&gt;
## View&lt;br /&gt;
### '''''Set Lens Angle''''' &lt;br /&gt;
#### related to the real endoscope lens angle&lt;br /&gt;
### control graphics and real endoscope&lt;br /&gt;
### '''''lock camera to the sensor, probe of the tracking device or Free view'''''&lt;br /&gt;
### camera calibration of different views of the endoscope camera&lt;br /&gt;
#### Transform fisheye view to normal view&lt;br /&gt;
### '''''flat colon screen (optional)'''''&lt;br /&gt;
# Navigation&lt;br /&gt;
## '''''view point control'''''&lt;br /&gt;
## '''''absolut and relative orientation and navigation of the camera'''''&lt;br /&gt;
## Set points in DICOM(2D viewer) at a certain position and slice, remain until clean up&lt;br /&gt;
### Points in higher/lower slides appear&lt;br /&gt;
### cleanup function for all points/certain points&lt;br /&gt;
## fiducials creation&lt;br /&gt;
### related to a selected model&lt;br /&gt;
# Aditional features&lt;br /&gt;
## texture mapping&lt;br /&gt;
### mapping a real picture to the surface of a specified model&lt;br /&gt;
### each texture  concatenate to a whole texture model&lt;br /&gt;
## freeze/pause slicer display &lt;br /&gt;
### no changes are possible&lt;br /&gt;
### save the current scene&lt;br /&gt;
## alarm function&lt;br /&gt;
### by an unstable magneticfield Alarm will occur&lt;/div&gt;</summary>
		<author><name>Ruetz</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=Neuroendoscope-igt&amp;diff=12433</id>
		<title>Neuroendoscope-igt</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=Neuroendoscope-igt&amp;diff=12433"/>
		<updated>2007-06-22T21:57:11Z</updated>

		<summary type="html">&lt;p&gt;Ruetz: /* functions */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;=functions=&lt;br /&gt;
# Interface&lt;br /&gt;
## '''''Generate a separate image rendering window to display captured endoscope view'''''&lt;br /&gt;
## '''''Make module with four pages'''''&lt;br /&gt;
# Display page&lt;br /&gt;
## '''''size of the windows'''''&lt;br /&gt;
## '''''show/hide them'''''&lt;br /&gt;
## changing the amount of viewable slices in DICOM Viewer&lt;br /&gt;
### option to see slices from one orientiation in a row &lt;br /&gt;
#### for example: slice 1 2 3 4 5 6 7 of an axial view (must be driveable)&lt;br /&gt;
# Registration page&lt;br /&gt;
## interfaces for ICP registration&lt;br /&gt;
### i/f to select partical surface for ICP (optional)&lt;br /&gt;
### using tracker (currently using NaviTrack, but IGSTK is preferable)&lt;br /&gt;
### i/f to give good intial guess&lt;br /&gt;
### i/f to foot switch (currently using NaviTrack, but IGSTK is preferable)&lt;br /&gt;
### re-registration function without restarting the whole procedure (previous/next steps support)&lt;br /&gt;
# Camera page&lt;br /&gt;
## Color Subframe &lt;br /&gt;
### '''''changing  color of the camera'''''&lt;br /&gt;
## Shape Subframe&lt;br /&gt;
### '''''show/hide Focal Point'''''&lt;br /&gt;
### '''''change size of the camera'''''&lt;br /&gt;
### '''''3D Gyro on/off switch'''''&lt;br /&gt;
### '''''Size changing of the Gyro'''''&lt;br /&gt;
### '''''different camera shapes'''''&lt;br /&gt;
## Probe Subframe&lt;br /&gt;
### '''''show/hide Sensor/Locator'''''&lt;br /&gt;
### '''''show/hide Probe''''' &lt;br /&gt;
### '''''show/hide guide (pointing tool (double length of Sensor/Locator)'''''&lt;br /&gt;
### '''''virtual ruler (in 0.1 cm steps) changeable by slider'''''&lt;br /&gt;
## View&lt;br /&gt;
### '''''Set Lens Angle''''' &lt;br /&gt;
#### related to the real endoscope lens angle&lt;br /&gt;
### control graphics and real endoscope&lt;br /&gt;
### '''''lock camera to the sensor, probe of the tracking device or Free view'''''&lt;br /&gt;
### camera calibration of different views of the endoscope camera&lt;br /&gt;
#### Transform fisheye view to normal view&lt;br /&gt;
### '''''flat colon screen (optional)'''''&lt;br /&gt;
# Navigation&lt;br /&gt;
## '''''view point control'''''&lt;br /&gt;
## '''''absolut and relative orientation and navigation of the camera'''''&lt;br /&gt;
## Set points in DICOM(2D viewer) at a certain position and slice, remain until clean up&lt;br /&gt;
### Points in higher/lower slides appear&lt;br /&gt;
### cleanup function for all points/certain points&lt;br /&gt;
## fiducials creation&lt;br /&gt;
### related to a selected model&lt;br /&gt;
# Aditional features&lt;br /&gt;
## freeze/pause slicer display &lt;br /&gt;
### no changes are possible&lt;br /&gt;
### save the current scene&lt;br /&gt;
## alarm function&lt;br /&gt;
### by an unstable magneticfield Alarm will occur&lt;/div&gt;</summary>
		<author><name>Ruetz</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=Neuroendoscope-igt&amp;diff=12432</id>
		<title>Neuroendoscope-igt</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=Neuroendoscope-igt&amp;diff=12432"/>
		<updated>2007-06-22T21:56:28Z</updated>

		<summary type="html">&lt;p&gt;Ruetz: /* functions */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;=functions=&lt;br /&gt;
# Interface&lt;br /&gt;
## '''''Generate a separate image rendering window to display captured endoscope view'''''&lt;br /&gt;
## '''''Make module with four pages'''''&lt;br /&gt;
# Display page&lt;br /&gt;
## '''''size of the windows'''''&lt;br /&gt;
## '''''show/hide them'''''&lt;br /&gt;
## changing the amount of viewable slices in DICOM Viewer&lt;br /&gt;
### option to see slices from one orientiation in a row &lt;br /&gt;
#### for example: slice 1 2 3 4 5 6 7 of an axial view (must be driveable)&lt;br /&gt;
# Registration page&lt;br /&gt;
## interfaces for ICP registration&lt;br /&gt;
### i/f to select partical surface for ICP (optional)&lt;br /&gt;
### using tracker (currently using NaviTrack, but IGSTK is preferable)&lt;br /&gt;
### i/f to give good intial guess&lt;br /&gt;
### i/f to foot switch (currently using NaviTrack, but IGSTK is preferable)&lt;br /&gt;
### re-registration function without restarting the whole procedure (previous/next steps support)&lt;br /&gt;
# Camera page&lt;br /&gt;
## Color Subframe &lt;br /&gt;
### '''''changing  color of the camera'''''&lt;br /&gt;
## Shape Subframe&lt;br /&gt;
### '''''show/hide Focal Point'''''&lt;br /&gt;
### '''''change size of the camera'''''&lt;br /&gt;
### '''''3D Gyro on/off switch'''''&lt;br /&gt;
### '''''Size changing of the Gyro'''''&lt;br /&gt;
### '''''different camera shapes'''''&lt;br /&gt;
## Probe Subframe&lt;br /&gt;
### '''''show/hide Sensor/Locator'''''&lt;br /&gt;
### '''''show/hide Probe''''' &lt;br /&gt;
### '''''show/hide guide (pointing tool (double length of Sensor/Locator)'''''&lt;br /&gt;
### '''''virtual ruler (in 0.1 cm steps) changeable by slider'''''&lt;br /&gt;
## View&lt;br /&gt;
### Set Lens Angle (related to the real endoscope lens angle)&lt;br /&gt;
### control graphics and real endoscope&lt;br /&gt;
### '''''lock camera to the sensor, probe of the tracking device or Free view'''''&lt;br /&gt;
### camera calibration of different views of the endoscope camera&lt;br /&gt;
#### Transform fisheye view to normal view&lt;br /&gt;
### '''''flat colon screen (optional)'''''&lt;br /&gt;
# Navigation&lt;br /&gt;
## '''''view point control'''''&lt;br /&gt;
## '''''absolut and relative orientation and navigation of the camera'''''&lt;br /&gt;
## Set points in DICOM(2D viewer) at a certain position and slice, remain until clean up&lt;br /&gt;
### Points in higher/lower slides appear&lt;br /&gt;
### cleanup function for all points/certain points&lt;br /&gt;
## fiducials creation&lt;br /&gt;
### related to a selected model&lt;br /&gt;
# Aditional features&lt;br /&gt;
## freeze/pause slicer display &lt;br /&gt;
### no changes are possible&lt;br /&gt;
### save the current scene&lt;br /&gt;
## alarm function&lt;br /&gt;
### by an unstable magneticfield Alarm will occur&lt;/div&gt;</summary>
		<author><name>Ruetz</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=Neuroendoscope-igt&amp;diff=12430</id>
		<title>Neuroendoscope-igt</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=Neuroendoscope-igt&amp;diff=12430"/>
		<updated>2007-06-22T21:41:37Z</updated>

		<summary type="html">&lt;p&gt;Ruetz: /* functions */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;=functions=&lt;br /&gt;
# Interface&lt;br /&gt;
## '''''Generate a separate image rendering window to display captured endoscope view'''''&lt;br /&gt;
## '''''Make module with four pages'''''&lt;br /&gt;
# Display page&lt;br /&gt;
## '''''size of the windows'''''&lt;br /&gt;
## '''''show/hide them'''''&lt;br /&gt;
## changing the amount of viewable slices in DICOM Viewer&lt;br /&gt;
### option to see slices from one orientiation in a row &lt;br /&gt;
#### for example: slice 1 2 3 4 5 6 7 of an axial view (must be driveable)&lt;br /&gt;
# Registration page&lt;br /&gt;
## interfaces for ICP registration&lt;br /&gt;
### i/f to select partical surface for ICP (optional)&lt;br /&gt;
### using tracker (currently using NaviTrack, but IGSTK is preferable)&lt;br /&gt;
### i/f to give good intial guess&lt;br /&gt;
### i/f to foot switch (currently using NaviTrack, but IGSTK is preferable)&lt;br /&gt;
### re-registration function without restarting the whole procedure (previous/next steps support)&lt;br /&gt;
# Camera page&lt;br /&gt;
## Color Subframe &lt;br /&gt;
### '''''changing  color of the camera'''''&lt;br /&gt;
## Shape Subframe&lt;br /&gt;
### '''''show/hide Focal Point'''''&lt;br /&gt;
### ''change size of the camera''&lt;br /&gt;
### '''''3D Gyro on/off switch'''''&lt;br /&gt;
### ''Size changing of the Gyro''&lt;br /&gt;
### '''''different camera shapes'''''&lt;br /&gt;
## Probe Subframe&lt;br /&gt;
### '''''show/hide Sensor/Locator'''''&lt;br /&gt;
### '''''show/hide Probe''''' &lt;br /&gt;
### '''''show/hide guide (pointing tool (double length of Sensor/Locator)'''''&lt;br /&gt;
### '''''virtual ruler (in 0.1 cm steps) changeable by slider'''''&lt;br /&gt;
## View&lt;br /&gt;
### Set Lens Angle (related to the real endoscope lens angle)&lt;br /&gt;
### control graphics and real endoscope&lt;br /&gt;
### '''''lock camera to the sensor, probe of the tracking device or Free view'''''&lt;br /&gt;
### camera calibration of different views of the endoscope camera&lt;br /&gt;
#### Transform fisheye view to normal view&lt;br /&gt;
### '''''flat colon screen (optional)'''''&lt;br /&gt;
# Navigation&lt;br /&gt;
## '''''view point control'''''&lt;br /&gt;
## '''''absolut and relative orientation and navigation of the camera'''''&lt;br /&gt;
## Set points in DICOM(2D viewer) at a certain position and slice, remain until clean up&lt;br /&gt;
### Points in higher/lower slides appear&lt;br /&gt;
### cleanup function for all points/certain points&lt;br /&gt;
## fiducials creation&lt;br /&gt;
### related to a selected model&lt;br /&gt;
# Aditional features&lt;br /&gt;
## freeze/pause slicer display &lt;br /&gt;
### no changes are possible&lt;br /&gt;
### save the current scene&lt;br /&gt;
## alarm function&lt;br /&gt;
### by an unstable magneticfield Alarm will occur&lt;/div&gt;</summary>
		<author><name>Ruetz</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=Neuroendoscope-igt&amp;diff=12426</id>
		<title>Neuroendoscope-igt</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=Neuroendoscope-igt&amp;diff=12426"/>
		<updated>2007-06-22T21:36:49Z</updated>

		<summary type="html">&lt;p&gt;Ruetz: /* functions */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;=functions=&lt;br /&gt;
# Interface&lt;br /&gt;
## '''''Generate a separate image rendering window to display captured endoscope view'''''&lt;br /&gt;
## '''''Make module with four pages'''''&lt;br /&gt;
# Display page&lt;br /&gt;
## '''''size of the windows'''''&lt;br /&gt;
## '''''show/hide them'''''&lt;br /&gt;
## changing the amount of viewable slices in DICOM Viewer&lt;br /&gt;
### option to see slices from one orientiation in a row &lt;br /&gt;
#### for example: slice 1 2 3 4 5 6 7 of an axial view (must be driveable)&lt;br /&gt;
# Registration page&lt;br /&gt;
## interfaces for ICP registration&lt;br /&gt;
### i/f to select partical surface for ICP (optional)&lt;br /&gt;
### using tracker (currently using NaviTrack, but IGSTK is preferable)&lt;br /&gt;
### i/f to give good intial guess&lt;br /&gt;
### i/f to foot switch (currently using NaviTrack, but IGSTK is preferable)&lt;br /&gt;
# Camera page&lt;br /&gt;
## Color Subframe &lt;br /&gt;
### '''''changing  color of the camera'''''&lt;br /&gt;
## Shape Subframe&lt;br /&gt;
### '''''show/hide Focal Point'''''&lt;br /&gt;
### ''change size of the camera''&lt;br /&gt;
### '''''3D Gyro on/off switch'''''&lt;br /&gt;
### ''Size changing of the Gyro''&lt;br /&gt;
### '''''different camera shapes'''''&lt;br /&gt;
## Probe Subframe&lt;br /&gt;
### '''''show/hide Sensor/Locator'''''&lt;br /&gt;
### '''''show/hide Probe''''' &lt;br /&gt;
### '''''show/hide guide (pointing tool (double length of Sensor/Locator)'''''&lt;br /&gt;
### '''''virtual ruler (in 0.1 cm steps) changeable by slider'''''&lt;br /&gt;
## View&lt;br /&gt;
### Set Lens Angle (related to the real endoscope lens angle)&lt;br /&gt;
### control graphics and real endoscope&lt;br /&gt;
### '''''lock camera to the sensor, probe of the tracking device or Free view'''''&lt;br /&gt;
### camera calibration of different views of the endoscope camera&lt;br /&gt;
#### Transform fisheye view to normal view&lt;br /&gt;
### '''''flat colon screen (optional)'''''&lt;br /&gt;
# Navigation&lt;br /&gt;
## '''''view point control'''''&lt;br /&gt;
## '''''absolut and relative orientation and navigation of the camera'''''&lt;br /&gt;
## Set points in DICOM(2D viewer) at a certain position and slice, remain until clean up&lt;br /&gt;
### Points in higher/lower slides appear&lt;br /&gt;
### cleanup function for all points/certain points&lt;br /&gt;
## fiducials creation&lt;br /&gt;
### related to a selected model&lt;br /&gt;
# Aditional features&lt;br /&gt;
## freeze/pause slicer display &lt;br /&gt;
### no changes are possible&lt;br /&gt;
### save the current scene&lt;br /&gt;
## alarm function&lt;br /&gt;
### by an unstable magneticfield Alarm will occur&lt;/div&gt;</summary>
		<author><name>Ruetz</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=Neuroendoscope-igt&amp;diff=12425</id>
		<title>Neuroendoscope-igt</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=Neuroendoscope-igt&amp;diff=12425"/>
		<updated>2007-06-22T21:36:31Z</updated>

		<summary type="html">&lt;p&gt;Ruetz: /* functions */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;=functions=&lt;br /&gt;
# Interface&lt;br /&gt;
## '''''Generate a separate image rendering window to display captured endoscope view'''''&lt;br /&gt;
## '''''Make module with four pages'''''&lt;br /&gt;
# Display page&lt;br /&gt;
## '''''size of the windows'''''&lt;br /&gt;
## '''''show/hide them'''''&lt;br /&gt;
## changing the amount viewable slices in DICOM Viewer&lt;br /&gt;
### option to see slices from one orientiation in a row &lt;br /&gt;
#### for example: slice 1 2 3 4 5 6 7 of an axial view (must be driveable)&lt;br /&gt;
# Registration page&lt;br /&gt;
## interfaces for ICP registration&lt;br /&gt;
### i/f to select partical surface for ICP (optional)&lt;br /&gt;
### using tracker (currently using NaviTrack, but IGSTK is preferable)&lt;br /&gt;
### i/f to give good intial guess&lt;br /&gt;
### i/f to foot switch (currently using NaviTrack, but IGSTK is preferable)&lt;br /&gt;
# Camera page&lt;br /&gt;
## Color Subframe &lt;br /&gt;
### '''''changing  color of the camera'''''&lt;br /&gt;
## Shape Subframe&lt;br /&gt;
### '''''show/hide Focal Point'''''&lt;br /&gt;
### ''change size of the camera''&lt;br /&gt;
### '''''3D Gyro on/off switch'''''&lt;br /&gt;
### ''Size changing of the Gyro''&lt;br /&gt;
### '''''different camera shapes'''''&lt;br /&gt;
## Probe Subframe&lt;br /&gt;
### '''''show/hide Sensor/Locator'''''&lt;br /&gt;
### '''''show/hide Probe''''' &lt;br /&gt;
### '''''show/hide guide (pointing tool (double length of Sensor/Locator)'''''&lt;br /&gt;
### '''''virtual ruler (in 0.1 cm steps) changeable by slider'''''&lt;br /&gt;
## View&lt;br /&gt;
### Set Lens Angle (related to the real endoscope lens angle)&lt;br /&gt;
### control graphics and real endoscope&lt;br /&gt;
### '''''lock camera to the sensor, probe of the tracking device or Free view'''''&lt;br /&gt;
### camera calibration of different views of the endoscope camera&lt;br /&gt;
#### Transform fisheye view to normal view&lt;br /&gt;
### '''''flat colon screen (optional)'''''&lt;br /&gt;
# Navigation&lt;br /&gt;
## '''''view point control'''''&lt;br /&gt;
## '''''absolut and relative orientation and navigation of the camera'''''&lt;br /&gt;
## Set points in DICOM(2D viewer) at a certain position and slice, remain until clean up&lt;br /&gt;
### Points in higher/lower slides appear&lt;br /&gt;
### cleanup function for all points/certain points&lt;br /&gt;
## fiducials creation&lt;br /&gt;
### related to a selected model&lt;br /&gt;
# Aditional features&lt;br /&gt;
## freeze/pause slicer display &lt;br /&gt;
### no changes are possible&lt;br /&gt;
### save the current scene&lt;br /&gt;
## alarm function&lt;br /&gt;
### by an unstable magneticfield Alarm will occur&lt;/div&gt;</summary>
		<author><name>Ruetz</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=Neuroendoscope-igt&amp;diff=12424</id>
		<title>Neuroendoscope-igt</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=Neuroendoscope-igt&amp;diff=12424"/>
		<updated>2007-06-22T21:36:06Z</updated>

		<summary type="html">&lt;p&gt;Ruetz: /* functions */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;=functions=&lt;br /&gt;
# Interface&lt;br /&gt;
## '''''Generate a separate image rendering window to display captured endoscope view'''''&lt;br /&gt;
## '''''Make module with four pages'''''&lt;br /&gt;
# Display page&lt;br /&gt;
## '''''size of the windows'''''&lt;br /&gt;
## '''''show/hide them'''''&lt;br /&gt;
## changing the amount viewable slices in DICOM Viewer&lt;br /&gt;
### option to see slices from one orientiation in a row &lt;br /&gt;
#### for example: slice 1 2 3 4 5 6 7 of an axial view (must be driveable)&lt;br /&gt;
# Registration page&lt;br /&gt;
## interfaces for ICP registration&lt;br /&gt;
### i/f to select partical surface for ICP (optional)&lt;br /&gt;
### using tracker (currently using NaviTrack, but IGSTK is preferable)&lt;br /&gt;
### i/f to give good intial guess&lt;br /&gt;
### i/f to foot switch (currently using NaviTrack, but IGSTK is preferable)&lt;br /&gt;
# Camera page&lt;br /&gt;
## Color Subframe &lt;br /&gt;
### '''''changing  color of the camera'''''&lt;br /&gt;
## Shape Subframe&lt;br /&gt;
### '''''show/hide Focal Point'''''&lt;br /&gt;
### ''change size of the camera''&lt;br /&gt;
### '''''3D Gyro on/off switch'''''&lt;br /&gt;
### ''Size changing of the Gyro''&lt;br /&gt;
### '''''different camera shapes'''''&lt;br /&gt;
## Probe Subframe&lt;br /&gt;
### '''''show/hide Sensor/Locator'''''&lt;br /&gt;
### '''''show/hide Probe''''' &lt;br /&gt;
### '''''show/hide guide (pointing tool (double length of Sensor/Locator)'''''&lt;br /&gt;
### virtual ruler (in 0.1 cm steps) changeable by slider&lt;br /&gt;
## View&lt;br /&gt;
### Set Lens Angle (related to the real endoscope lens angle)&lt;br /&gt;
### control graphics and real endoscope&lt;br /&gt;
### '''''lock camera to the sensor, probe of the tracking device or Free view'''''&lt;br /&gt;
### camera calibration of different views of the endoscope camera&lt;br /&gt;
#### Transform fisheye view to normal view&lt;br /&gt;
### '''''flat colon screen (optional)'''''&lt;br /&gt;
# Navigation&lt;br /&gt;
## '''''view point control'''''&lt;br /&gt;
## '''''absolut and relative orientation and navigation of the camera'''''&lt;br /&gt;
## Set points in DICOM(2D viewer) at a certain position and slice, remain until clean up&lt;br /&gt;
### Points in higher/lower slides appear&lt;br /&gt;
### cleanup function for all points/certain points&lt;br /&gt;
## fiducials creation&lt;br /&gt;
### related to a selected model&lt;br /&gt;
# Aditional features&lt;br /&gt;
## freeze/pause slicer display &lt;br /&gt;
### no changes are possible&lt;br /&gt;
### save the current scene&lt;br /&gt;
## alarm function&lt;br /&gt;
### by an unstable magneticfield Alarm will occur&lt;/div&gt;</summary>
		<author><name>Ruetz</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=Neuroendoscope-igt&amp;diff=12415</id>
		<title>Neuroendoscope-igt</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=Neuroendoscope-igt&amp;diff=12415"/>
		<updated>2007-06-22T21:10:08Z</updated>

		<summary type="html">&lt;p&gt;Ruetz: /* functions */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;=functions=&lt;br /&gt;
# Interface&lt;br /&gt;
## '''''Generate a separate image rendering window to display captured endoscope view'''''&lt;br /&gt;
## '''''Make module with four pages'''''&lt;br /&gt;
# Display page&lt;br /&gt;
## '''''size of the windows'''''&lt;br /&gt;
## '''''show/hide them'''''&lt;br /&gt;
# Registration page&lt;br /&gt;
## interfaces for ICP registration&lt;br /&gt;
### i/f to select partical surface for ICP (optional)&lt;br /&gt;
### using tracker (currently using NaviTrack, but IGSTK is preferable)&lt;br /&gt;
### i/f to give good intial guess&lt;br /&gt;
### i/f to foot switch (currently using NaviTrack, but IGSTK is preferable)&lt;br /&gt;
# Camera page&lt;br /&gt;
## Color Subframe &lt;br /&gt;
### '''''changing  color of the camera'''''&lt;br /&gt;
## Shape Subframe&lt;br /&gt;
### '''''show/hide Focal Point'''''&lt;br /&gt;
### ''change size of the camera''&lt;br /&gt;
### '''''3D Gyro on/off switch'''''&lt;br /&gt;
### ''Size changing of the Gyro''&lt;br /&gt;
### '''''different camera shapes'''''&lt;br /&gt;
## Probe Subframe&lt;br /&gt;
### '''''show/hide Sensor/Locator'''''&lt;br /&gt;
### show/hide Probe &lt;br /&gt;
### show/hide guide (pointing tool (double length of Sensor/Locator)&lt;br /&gt;
### virtual ruler (in 0.1 cm steps) changeable by slider&lt;br /&gt;
## View&lt;br /&gt;
### Set Lens Angle (related to the real endoscope lens angle)&lt;br /&gt;
### control graphics and real endoscope&lt;br /&gt;
### '''''lock camera to the sensor, probe of the tracking device or Free view'''''&lt;br /&gt;
### camera calibration of different views of the endoscope camera&lt;br /&gt;
#### Transform fisheye view to normal view&lt;br /&gt;
### '''''flat colon screen (optional)'''''&lt;br /&gt;
# Navigation&lt;br /&gt;
## '''''view point control'''''&lt;br /&gt;
## '''''absolut and relative orientation and navigation of the camera'''''&lt;br /&gt;
## Set points in DICOM(2D viewer) at a certain position and slice, remain until clean up&lt;br /&gt;
### Points in higher/lower slides appear&lt;br /&gt;
### cleanup function for all points/certain points&lt;br /&gt;
## fiducials creation&lt;br /&gt;
### related to a selected model&lt;br /&gt;
# Aditional features&lt;br /&gt;
## freeze/pause slicer display &lt;br /&gt;
### no changes are possible&lt;br /&gt;
### save the current scene&lt;br /&gt;
## alarm function&lt;br /&gt;
### by an unstable magneticfield Alarm will occur&lt;/div&gt;</summary>
		<author><name>Ruetz</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=Neuroendoscope-igt&amp;diff=12413</id>
		<title>Neuroendoscope-igt</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=Neuroendoscope-igt&amp;diff=12413"/>
		<updated>2007-06-22T20:47:00Z</updated>

		<summary type="html">&lt;p&gt;Ruetz: /* functions */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;=functions=&lt;br /&gt;
# Interface&lt;br /&gt;
## ''Generate a separate image rendering window to display captured endoscope view''&lt;br /&gt;
## ''Make module with four pages''&lt;br /&gt;
# Display page&lt;br /&gt;
## ''size of the windows''&lt;br /&gt;
## ''show/hide them''&lt;br /&gt;
# Registration page&lt;br /&gt;
## interfaces for ICP registration&lt;br /&gt;
### i/f to select partical surface for ICP (optional)&lt;br /&gt;
### using tracker (currently using NaviTrack, but IGSTK is preferable)&lt;br /&gt;
### i/f to give good intial guess&lt;br /&gt;
### i/f to foot switch (currently using NaviTrack, but IGSTK is preferable)&lt;br /&gt;
# Camera page&lt;br /&gt;
## Color Subframe &lt;br /&gt;
### ''changing  color of the camera''&lt;br /&gt;
## Shape Subframe&lt;br /&gt;
### ''show/hide Focal Point''&lt;br /&gt;
### ''change size of the camera''&lt;br /&gt;
### ''3D Gyro on/off switch''&lt;br /&gt;
### ''Size changing of the Gyro''&lt;br /&gt;
### ''different camera shapes''&lt;br /&gt;
## Probe Subframe&lt;br /&gt;
### ''show/hide Sensor/Locator''&lt;br /&gt;
### show/hide Probe &lt;br /&gt;
### show/hide guide (pointing tool (double length of Sensor/Locator)&lt;br /&gt;
### virtual ruler (in 0.1 cm steps) changeable by slider&lt;br /&gt;
## View&lt;br /&gt;
### Set Lens Angle (related to the real endoscope lens angle)&lt;br /&gt;
### control graphics and real endoscope&lt;br /&gt;
### ''lock camera to the sensor, probe of the tracking device or Free view''&lt;br /&gt;
### camera calibration of different views of the endoscope camera&lt;br /&gt;
#### Transform fisheye view to normal view&lt;br /&gt;
### ''flat colon screen (optional)''&lt;br /&gt;
# Navigation&lt;br /&gt;
## ''view point control''&lt;br /&gt;
## ''absolut and relative orientation and navigation of the camera''&lt;br /&gt;
## Set points in DICOM(2D viewer) at a certain position and slice, remain until clean up&lt;br /&gt;
### Points in higher/lower slides appear&lt;br /&gt;
### cleanup function for all points/certain points&lt;br /&gt;
## fiducials creation&lt;br /&gt;
### related to a selected model&lt;br /&gt;
# Aditional features&lt;br /&gt;
## freeze/pause slicer display &lt;br /&gt;
### no changes are possible&lt;br /&gt;
### save the current scene&lt;br /&gt;
## alarm function&lt;br /&gt;
### by an unstable magneticfield Alarm will occur&lt;/div&gt;</summary>
		<author><name>Ruetz</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=Neuroendoscope-igt&amp;diff=12412</id>
		<title>Neuroendoscope-igt</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=Neuroendoscope-igt&amp;diff=12412"/>
		<updated>2007-06-22T20:41:10Z</updated>

		<summary type="html">&lt;p&gt;Ruetz: /* functions */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;=functions=&lt;br /&gt;
# Interface&lt;br /&gt;
## Generated a separate image rendering window to display captured endoscope view&lt;br /&gt;
## Make module with four pages&lt;br /&gt;
# Display page&lt;br /&gt;
## size of the windows&lt;br /&gt;
## show/hide them&lt;br /&gt;
# Registration page&lt;br /&gt;
## interfaces for ICP registration&lt;br /&gt;
### i/f to select partical surface for ICP (optional)&lt;br /&gt;
### using tracker (currently using NaviTrack, but IGSTK is preferable)&lt;br /&gt;
### i/f to give good intial guess&lt;br /&gt;
### i/f to foot switch &lt;br /&gt;
# Camera page&lt;br /&gt;
## Color Subframe &lt;br /&gt;
### changing  color of the camera&lt;br /&gt;
## Shape Subframe&lt;br /&gt;
### changing the Focal Point&lt;br /&gt;
### change size of the camera&lt;br /&gt;
### 3D Gyro on/off switch&lt;br /&gt;
### Size changing of the Gyro&lt;br /&gt;
## Probe Subframe&lt;br /&gt;
### show/hide Sensor/Locator&lt;br /&gt;
### show/hide Probe &lt;br /&gt;
### show/hide guide (pointing tool (double length of Sensor/Locator)&lt;br /&gt;
### virtual ruler (in 0.1 cm steps) changeable by slider&lt;br /&gt;
## View&lt;br /&gt;
### Set Lens Angle (related to the real endoscope lens angle)&lt;br /&gt;
### control graphics and real endoscope ()&lt;br /&gt;
### lock camera to the sensor, probe of the tracking device or Free view&lt;br /&gt;
### camera calibration of different views of the endoscope camera&lt;br /&gt;
#### Transform fisheye view to normal view&lt;br /&gt;
### flat colon screen (optional)&lt;br /&gt;
# Navigation&lt;br /&gt;
## view point control&lt;br /&gt;
## absolut and relative orientation and navigation of the camera&lt;br /&gt;
## Set points in DICOM(2D viewer) at a certain position and slice, remain until clean up&lt;br /&gt;
### Points in higher/lower slides appear&lt;br /&gt;
### cleanup function for all points/certain points&lt;br /&gt;
## fiducials creation&lt;br /&gt;
### related to a selected model&lt;br /&gt;
# Aditional features&lt;br /&gt;
## freeze/pause slicer display &lt;br /&gt;
### no changes are possible&lt;br /&gt;
### save the current scene&lt;br /&gt;
## alarm function&lt;br /&gt;
### by an unstable magneticfield Alarm will occur&lt;/div&gt;</summary>
		<author><name>Ruetz</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=Neuroendoscope-igt&amp;diff=12411</id>
		<title>Neuroendoscope-igt</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=Neuroendoscope-igt&amp;diff=12411"/>
		<updated>2007-06-22T20:40:59Z</updated>

		<summary type="html">&lt;p&gt;Ruetz: /* functions */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;=functions=&lt;br /&gt;
# Interface&lt;br /&gt;
## Generated a separate image rendering window to display captured endoscope view&lt;br /&gt;
## Make module with four pages&lt;br /&gt;
# Display page&lt;br /&gt;
## size of the windows&lt;br /&gt;
## show/hide them&lt;br /&gt;
# Registration page&lt;br /&gt;
## interfaces for ICP registration&lt;br /&gt;
### i/f to select partical surface for ICP (optional)&lt;br /&gt;
### using tracker (currently using NaviTrack, but IGSTK is preferable)&lt;br /&gt;
### i/f to give good intial guess&lt;br /&gt;
### i/f to foot switch &lt;br /&gt;
&lt;br /&gt;
# Camera page&lt;br /&gt;
## Color Subframe &lt;br /&gt;
### changing  color of the camera&lt;br /&gt;
## Shape Subframe&lt;br /&gt;
### changing the Focal Point&lt;br /&gt;
### change size of the camera&lt;br /&gt;
### 3D Gyro on/off switch&lt;br /&gt;
### Size changing of the Gyro&lt;br /&gt;
## Probe Subframe&lt;br /&gt;
### show/hide Sensor/Locator&lt;br /&gt;
### show/hide Probe &lt;br /&gt;
### show/hide guide (pointing tool (double length of Sensor/Locator)&lt;br /&gt;
### virtual ruler (in 0.1 cm steps) changeable by slider&lt;br /&gt;
## View&lt;br /&gt;
### Set Lens Angle (related to the real endoscope lens angle)&lt;br /&gt;
### control graphics and real endoscope ()&lt;br /&gt;
### lock camera to the sensor, probe of the tracking device or Free view&lt;br /&gt;
### camera calibration of different views of the endoscope camera&lt;br /&gt;
#### Transform fisheye view to normal view&lt;br /&gt;
### flat colon screen (optional)&lt;br /&gt;
# Navigation&lt;br /&gt;
## view point control&lt;br /&gt;
## absolut and relative orientation and navigation of the camera&lt;br /&gt;
## Set points in DICOM(2D viewer) at a certain position and slice, remain until clean up&lt;br /&gt;
### Points in higher/lower slides appear&lt;br /&gt;
### cleanup function for all points/certain points&lt;br /&gt;
## fiducials creation&lt;br /&gt;
### related to a selected model&lt;br /&gt;
# Aditional features&lt;br /&gt;
## freeze/pause slicer display &lt;br /&gt;
### no changes are possible&lt;br /&gt;
### save the current scene&lt;br /&gt;
## alarm function&lt;br /&gt;
### by an unstable magneticfield Alarm will occur&lt;/div&gt;</summary>
		<author><name>Ruetz</name></author>
		
	</entry>
	<entry>
		<id>https://www.na-mic.org/w/index.php?title=Neuroendoscope-igt&amp;diff=12410</id>
		<title>Neuroendoscope-igt</title>
		<link rel="alternate" type="text/html" href="https://www.na-mic.org/w/index.php?title=Neuroendoscope-igt&amp;diff=12410"/>
		<updated>2007-06-22T20:40:11Z</updated>

		<summary type="html">&lt;p&gt;Ruetz: /* functions */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;=functions=&lt;br /&gt;
#Interface&lt;br /&gt;
##Generated a separate image rendering window to display captured endoscope view&lt;br /&gt;
##Make module with four pages&lt;br /&gt;
&lt;br /&gt;
#Display page&lt;br /&gt;
## size of the windows&lt;br /&gt;
## show/hide them&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
#Registration page&lt;br /&gt;
## interfaces for ICP registration&lt;br /&gt;
### i/f to select partical surface for ICP (optional)&lt;br /&gt;
### using tracker (currently using NaviTrack, but IGSTK is preferable)&lt;br /&gt;
### i/f to give good intial guess&lt;br /&gt;
### i/f to foot switch &lt;br /&gt;
&lt;br /&gt;
#Camera page&lt;br /&gt;
## Color Subframe &lt;br /&gt;
### changing  color of the camera&lt;br /&gt;
## Shape Subframe&lt;br /&gt;
### changing the Focal Point&lt;br /&gt;
### change size of the camera&lt;br /&gt;
### 3D Gyro on/off switch&lt;br /&gt;
### Size changing of the Gyro&lt;br /&gt;
## Probe Subframe&lt;br /&gt;
### show/hide Sensor/Locator&lt;br /&gt;
### show/hide Probe &lt;br /&gt;
### show/hide guide (pointing tool (double length of Sensor/Locator)&lt;br /&gt;
### virtual ruler (in 0.1 cm steps) changeable by slider&lt;br /&gt;
## View&lt;br /&gt;
### Set Lens Angle (related to the real endoscope lens angle)&lt;br /&gt;
### control graphics and real endoscope ()&lt;br /&gt;
### lock camera to the sensor, probe of the tracking device or Free view&lt;br /&gt;
### camera calibration of different views of the endoscope camera&lt;br /&gt;
#### Transform fisheye view to normal view&lt;br /&gt;
### flat colon screen (optional)&lt;br /&gt;
&lt;br /&gt;
#Navigation&lt;br /&gt;
## view point control&lt;br /&gt;
## absolut and relative orientation and navigation of the camera&lt;br /&gt;
## Set points in DICOM(2D viewer) at a certain position and slice, remain until clean up&lt;br /&gt;
### Points in higher/lower slides appear&lt;br /&gt;
### cleanup function for all points/certain points&lt;br /&gt;
&lt;br /&gt;
## fiducials creation&lt;br /&gt;
### related to a selected model&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
#Aditional features&lt;br /&gt;
## freeze/pause slicer display &lt;br /&gt;
### no changes are possible&lt;br /&gt;
### save the current scene&lt;br /&gt;
## alarm function&lt;br /&gt;
### by an unstable magneticfield Alarm will occur&lt;/div&gt;</summary>
		<author><name>Ruetz</name></author>
		
	</entry>
</feed>