Algorithm:GATech:Finsler Active Contour DWI

From NAMIC Wiki
Revision as of 20:59, 13 April 2007 by Tkapur (talk | contribs)
Jump to: navigation, search
Home < Algorithm:GATech:Finsler Active Contour DWI
Back to NA-MIC_Collaborations

Objective:

We want to extract the white matter tracts from Diffusion Weighted MRI scans. The idea is to use directional information in a new anisotropic energy functional based on Finsler geometry.

Progress:

We have implemented the algorithm in Matlab/C using the Fast Sweeping algorithm. We are in the process of porting the code to ITK.

We are continuing to work on our new framework for white matter tractography in high angular resolution diffusion data. We base our work on concepts from Finsler geometry. Namely, a direction-dependent local cost is defined based on the diffusion data for every direction on the unit sphere. Minimum cost curves are determined by solving the Hamilton-Jacobi-Bellman using the Fast Sweeping algorithm. Classical costs based on the diffusion tensor field can be seen as a special case. While the minimum cost (or equivalently the travel time of a particle moving along the curve) and the anisotropic front propagation frameworks are related, front speed is related to particle speed through a Legendre transformation which can severely impact anisotropy information for front propagation techniques. Implementation details and results on high angular diffusion data show that this method can successfully take advantage of the increased angular resolution in high b-value diffusion weighted data despite lower signal to noise ratio.

Data

We are using Harvard's high angular resolution datasets which currently consist of a population of 12 schizophrenics and 12 normal controls.

Results

Recently, we have applied this method to the cingulum bundle, as shown in the following images:

Case24-coronal-tensors-edit.png Detailed View of the Cingulum Bundle Anchor Tract Case25-sagstream-tensors-edit.png Streamline Comparison
Case26-anterior.png Anterior View of the Cingulum Bundle Anchor Tract Case26-posterior.png Posterior View of the Cingulum Bundle Anchor Tract

Previously, this method was applied to full brain fiber tractography, as shown in the following images:

Tracts1.png Fiber tracking from high resolution data set. Tracts2.png Comparison of technique with streamline based on tensor field.

This method may also be used in pattern detection applications, such as vessel segmentation:

Vessels1.png Vessel Segmentation.

Project Status

  • Working 3D implementation in Matlab using the C-based Mex functions.
  • Currently porting to ITK.

References:

  • J. Melonakos, V. Mohan, M. Niethammer, K. Smith, M. Kubicki, and A. Tannenbaum. Under review.
  • J. Melonakos, E. Pichon, S. Angenet, and A. Tannenbaum. Finsler Active Contours for Directional Segmentation. IEEE Transactions on Pattern Analysis and Machine Intelligence, 2007.
  • E. Pichon and A. Tannenbaum. Curve segmentation using directional information, relation to pattern detection. In IEEE International Conference on Image Processing (ICIP), volume 2, pages 794-797, 2005.
  • E. Pichon, C-F Westin, and A. Tannenbaum. A Hamilton-Jacobi-Bellman approach to high angular resolution diffusion tractography. In International Conference on Medical Image Computing and Computer Assisted Intervention (MICCAI), pages 180-187, 2005

Key Investigators:

  • Georgia Tech: John Melonakos, Vandana Mohan, Allen Tannenbaum
  • Harvard/BWH: Marek Kubicki, Marc Niethammer, Kate Smith, C-F Westin, Martha Shenton

Links: