Difference between revisions of "Inter-slice Motion Correction for fMRI"

From NAMIC Wiki
Jump to: navigation, search
Line 10: Line 10:
  
 
== Results ==
 
== Results ==
 +
 +
=== Original Images ===
 +
 +
[[Image:original_image_004.png]]
 +
Original data with motion artefacts
 +
 
=== Affine ===
 
=== Affine ===
 
* affine motion with all metrics degrades the inter-slice registration.  
 
* affine motion with all metrics degrades the inter-slice registration.  

Revision as of 21:45, 24 October 2007

Home < Inter-slice Motion Correction for fMRI

Objective

   * To perform inter-slice motion correction in fMR images using affine and non-rigid registration methods. 


Progress

   * Implemented and tested b-Spline/affine registration with Mattes-MI and KL metrics. 
   * Coding completed. However, results are far from satisfactory.
   * Progress (maybe) stymied by "poor" resolution of data.
   * Progress (maybe) stymied by "not-so-viable" metrics (MI, etc.).

Results

Original Images

Original image 004.png Original data with motion artefacts

Affine

  • affine motion with all metrics degrades the inter-slice registration.

Non-Rigid

  • B-spline deformation with KL metric produces very minimal change (in a least squares sense), while MI produces more changes but doesn't look correct.

Images

Firdaus image 004.png Original fMRI


Original.jpg Volume rendering of original volume


Resampled.jpg Volume rendering of up-sampled volume (0.5x0.5mm in axial plane)

Affine-rms-registered.jpg Volume rendering of co-registered volume

Firdaus affine rms.png Volume rendering of affine motion with mean square error metric

Firdaus affine mi.png Affine motion with Mattes MI error metric

Issues

  • As can be seen any registration result looks more jagged (along the sagittal and coronal sections).
  • Low sampling rate and image noise - all the metrics are extremely non-smooth as a result.
  • Even the slightest change in initialization results in a large deviation in the registration result.

Open questions

   * Intensity normalization / histogram equalization - would these have any impact on inter-slice registration? Would they affect the computation of the joint-entropies for MI/KL metrics.
   * Should there be some regularization factor on the registration to limit the motion ?

To Do

   * Right now, registration is done on a slice by slice basis. However, due to the low resolution of fMRI and the absence of gradients result in low registration accuracy. We are investigating using alternative image-to-image metrics like the KL divergence. We are also looking at simultaneously registering multiple slices.

Key Investigators

   * Firdaus Janoos, Raghu Machiraju, Steve Pieper, Wendy Plesniak.

Links