− | + | '''Step 1''': Prepare the data using the instructions -- LINK | |
− | + | ||
− | + | '''Step 2''': Gradient anisotropic diffusion. Tools: Slicer GAD module. Parameters: time step: 0.0625, iterations: 5, conductance: 1. | |
− | + | ||
− | + | '''Step 3''': Initial registration 6+9+12 DOF registration. Tools: BRAINSFit svn r301. Parameters: default except CenterOfHead initializer with ROIAUTO sampling region. Comments: failure to recover the pose for Hugo and Valentino (both have severe head tilt in all three planes). Execution time: ~2 min per subject. | |
− | + | ||
− | + | '''Step 4''': Manual pose alignment for Hugo and Valentino. Transforms "hardened" in Slicer MRML, volumes saved and re-registered same way as described in Step 3. Registration issue resolved. Tools: Slicer Transforms module, BRAINSFit. | |
− | + | ||
− | + | '''Step 5''': Manual ICC for Tommy. Tools: itkSNAP, manual editing by Ginger. | |
− | + | ||
+ | '''Step 6''': Editing of ICC label map. Tools: Slicer smoothing label map module. Parameters: 10 iterations. | ||
+ | |||
+ | '''Step 7''': Manual mask dilation, so that each brain of each subject following registration in Step is contained. Tools: Slicer Editor module. Parameters: 8-neighbor, repeated 3 times. | ||
+ | |||
+ | '''Step 8''': Resampling of the ICC to each subject. Tools: Slicer ResampleVolume2 command line module. Parameters: NN interpolation. | ||
+ | |||
+ | '''Step 9''': Bias field correction with ICC. Tools: Slicer N3MRILightCLI extension. Parameters: default values except number of iterations increased from 50 to 100, convergence threshold decreased from 0.001 to 0.0001, ICC label from Step 8. Execution time: < 2 min per subject. | ||
+ | |||
+ | '''Step 10 -- we are here right now''': Pipelined registration (6+9+12+BSpline). Tried: (1) ICC ROI from step for moving floating, BSpline step segfaults; (2) ROIAUTO (same as in Step 3), BSpline completes, but resampled volume does not make any sense. AF: I suspect BSpline registration may not be able to handle non-axis-aligned volumes. |
Revision as of 03:48, 9 October 2009
Home < October 08 2009 Meeting: VT-NAMIC Revised atlas construction workflowTODOs
- link the software tools and scripts with the workflow
- prepare a branch in the sandbox with the tools not available in Slicer (confirm with Chris copyright issues)
Software
- Slicer/extensions versioning
Workflow
Step 1: Prepare the data using the instructions -- LINK
Step 2: Gradient anisotropic diffusion. Tools: Slicer GAD module. Parameters: time step: 0.0625, iterations: 5, conductance: 1.
Step 3: Initial registration 6+9+12 DOF registration. Tools: BRAINSFit svn r301. Parameters: default except CenterOfHead initializer with ROIAUTO sampling region. Comments: failure to recover the pose for Hugo and Valentino (both have severe head tilt in all three planes). Execution time: ~2 min per subject.
Step 4: Manual pose alignment for Hugo and Valentino. Transforms "hardened" in Slicer MRML, volumes saved and re-registered same way as described in Step 3. Registration issue resolved. Tools: Slicer Transforms module, BRAINSFit.
Step 5: Manual ICC for Tommy. Tools: itkSNAP, manual editing by Ginger.
Step 6: Editing of ICC label map. Tools: Slicer smoothing label map module. Parameters: 10 iterations.
Step 7: Manual mask dilation, so that each brain of each subject following registration in Step is contained. Tools: Slicer Editor module. Parameters: 8-neighbor, repeated 3 times.
Step 8: Resampling of the ICC to each subject. Tools: Slicer ResampleVolume2 command line module. Parameters: NN interpolation.
Step 9: Bias field correction with ICC. Tools: Slicer N3MRILightCLI extension. Parameters: default values except number of iterations increased from 50 to 100, convergence threshold decreased from 0.001 to 0.0001, ICC label from Step 8. Execution time: < 2 min per subject.
Step 10 -- we are here right now: Pipelined registration (6+9+12+BSpline). Tried: (1) ICC ROI from step for moving floating, BSpline step segfaults; (2) ROIAUTO (same as in Step 3), BSpline completes, but resampled volume does not make any sense. AF: I suspect BSpline registration may not be able to handle non-axis-aligned volumes.