'''To Do:'''
+
'''Publications:'''
* Evaluate automated segmentation algorithms to the Physical laser scans
+
* DeVries NA, Gassman EE, Kallemeyn NA, Shivanna KH, Magnotta VA, Grosland NM. [http://www.springerlink.com/content/u36v5957k17536wt/ Validation of phalanx bone three-dimensional surface segmentation from computed tomography images using laser scanning]. Skeletal Radiol. 37(1):35-42, 2008.  
*# Neural network segmentation
 
*# EM Segmenter
 
* Integrate surface orientation and registration tools into Slicer3
 
* Integrate surface distance map tools into Slicer3 - These could be useful for other applications as well.
 
  
  
Line 31: Line 27:
  
 
'''References:'''
 
'''References:'''
* Validation of Phalanx Bone 3D Surface Segmentation from CT Images Using Laser Scanning, Skeletal Radiology, In press.
+
* [http://www.springerlink.com/content/u36v5957k17536wt/ Devries NA, Gassman EE, Kallemeyn NA, Shivanna KH, Magnotta VA, Grosland NM. Validation of Phalanx Bone 3D Surface Segmentation from CT Images Using Laser Scanning, Skeletal Radiology, 2007]
  
 
'''Figures:'''
 
'''Figures:'''
 +
 +
[[Image:DistanceMapTool.jpg|left|thumb|300px|Surface distance mapping tool developed in FLTK]]
 +
 +
[[Image:DistanceMap.png|left|thumb|300px|Surface Distance Map for a phalanx bone between a surface manually defined via CT and a physical surface laser scan.]]
 +
 +
[[Image:SurfaceOverlay.png|left|thumb|200px|Overlay of the physical surface (White) and CT based surface (Purple)]]

Latest revision as of 18:32, 20 January 2010

Home < Validation of Defined Regions of Interest Using Surface Scanning

Objective:

  • To evaluate manual and automated segmentation routines using surface scans of disected bones from cadaveric specimens

Progress:

  • CT images of the hand and wrist have been obtained
  • Four hands have been disected and bones extracted
  • Surface scanning for these disected bones is completed using a Roland LPX-250 Laser Scanner
  • Manual tracing of the CT images is completed
  • Evaluate reliability of the manual tracers is complete using relative overlap
  • Tools have been developed to reorient surface axes and to register the manually defined model and the surface resulting from laser scanning
  • Distance maps for the manual segmentation have been generated.
  • The effect of various post processing routines have been studied relative to changes in the surface geometry relative to the laser scan.


Publications:


Key Investigators:

  • Iowa: Nicole Grosland, Vincent Magnotta, Nicole DeVries

Links:

References:

Figures:

Surface distance mapping tool developed in FLTK
Surface Distance Map for a phalanx bone between a surface manually defined via CT and a physical surface laser scan.
Overlay of the physical surface (White) and CT based surface (Purple)