* CT images of the hand and wrist have been obtained
 
* CT images of the hand and wrist have been obtained
 
* Four hands have been disected and bones extracted
 
* Four hands have been disected and bones extracted
* Surface scanning for these disected bones is currenrtly underway
+
* Surface scanning for these disected bones is completed using a Roland LPX-250 Laser Scanner
 +
* Manual tracing of the CT images is completed
 +
* Evaluate reliability of the manual tracers is complete using relative overlap
 +
* Tools have been developed to reorient surface axes and to register the manually defined model and the surface resulting from laser scanning
 +
* Distance maps for the manual segmentation have been generated.
 +
* The effect of various post processing routines have been studied relative to changes in the surface geometry relative to the laser scan.
 +
 
 +
 
 +
'''Publications:'''
 +
* DeVries NA, Gassman EE, Kallemeyn NA, Shivanna KH, Magnotta VA, Grosland NM. [http://www.springerlink.com/content/u36v5957k17536wt/ Validation of phalanx bone three-dimensional surface segmentation from computed tomography images using laser scanning]. Skeletal Radiol. 37(1):35-42, 2008.
  
'''To Do:'''
 
* Complete manual tracing from the CT images
 
* Evaluate reliability of the manual tracers
 
* Run Neural network segmentation and EM Segmenter on the CT scans
 
* Compare the results to the surface scans
 
  
 
'''Key Investigators:'''
 
'''Key Investigators:'''
Line 22: Line 26:
 
*[http://www.ccad.uiowa.edu/mimx Musculoskeletal Imaging, Modelling and Experimentation (MIMX)]
 
*[http://www.ccad.uiowa.edu/mimx Musculoskeletal Imaging, Modelling and Experimentation (MIMX)]
  
'''Description:'''
+
'''References:'''
This page is currently a place holder for a year two project for the Meshing grant
+
* [http://www.springerlink.com/content/u36v5957k17536wt/ Devries NA, Gassman EE, Kallemeyn NA, Shivanna KH, Magnotta VA, Grosland NM. Validation of Phalanx Bone 3D Surface Segmentation from CT Images Using Laser Scanning, Skeletal Radiology, 2007]
 +
 
 +
'''Figures:'''
 +
 
 +
[[Image:DistanceMapTool.jpg|left|thumb|300px|Surface distance mapping tool developed in FLTK]]
 +
 
 +
[[Image:DistanceMap.png|left|thumb|300px|Surface Distance Map for a phalanx bone between a surface manually defined via CT and a physical surface laser scan.]]
 +
 
 +
[[Image:SurfaceOverlay.png|left|thumb|200px|Overlay of the physical surface (White) and CT based surface (Purple)]]

Latest revision as of 18:32, 20 January 2010

Home < Validation of Defined Regions of Interest Using Surface Scanning

Objective:

  • To evaluate manual and automated segmentation routines using surface scans of disected bones from cadaveric specimens

Progress:

  • CT images of the hand and wrist have been obtained
  • Four hands have been disected and bones extracted
  • Surface scanning for these disected bones is completed using a Roland LPX-250 Laser Scanner
  • Manual tracing of the CT images is completed
  • Evaluate reliability of the manual tracers is complete using relative overlap
  • Tools have been developed to reorient surface axes and to register the manually defined model and the surface resulting from laser scanning
  • Distance maps for the manual segmentation have been generated.
  • The effect of various post processing routines have been studied relative to changes in the surface geometry relative to the laser scan.


Publications:


Key Investigators:

  • Iowa: Nicole Grosland, Vincent Magnotta, Nicole DeVries