Difference between revisions of "Projects:RegistrationLibrary:RegLib C15"
From NAMIC Wiki
m (Text replacement - "http://www.slicer.org/slicerWiki/index.php/" to "https://www.slicer.org/wiki/") |
|||
(5 intermediate revisions by 2 users not shown) | |||
Line 3: | Line 3: | ||
[[Projects:RegistrationDocumentation:UseCaseInventory|Back to Registration Use-case Inventory]] <br> | [[Projects:RegistrationDocumentation:UseCaseInventory|Back to Registration Use-case Inventory]] <br> | ||
− | ==Slicer Registration | + | |
− | {| style="color:#bbbbbb | + | ==<small>v3.6.1</small> [[Image:Slicer3-6Announcement-v1.png|150px]] Slicer Registration Library Case #15: <br>Brain MR Alignment along AC-PC line== |
− | |[[Image:RegLib_C15_Fiducials. | + | === Input === |
− | |[[Image: | + | {| style="color:#bbbbbb; " cellpadding="10" cellspacing="0" border="0" |
− | |[[Image:RegLib_C15_MRI.png|150px|lleft|this is the moving image | + | |[[Image:RegLib_C15_Fiducials.png|150px|lleft|this is the fixed reference image. All images are aligned into this space]] |
− | + | |[[Image:RegArrow_Rigid.png|100px|lleft]] | |
− | + | |[[Image:RegLib_C15_MRI.png|150px|lleft|this is the moving image. The transform is calculated by matching this to the reference image]] | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | |fixed image/target |
| | | | ||
− | | | + | |moving image |
|} | |} | ||
− | === | + | |
+ | === Modules === | ||
+ | *[https://www.slicer.org/wiki/Modules:ACPCTransform-Documentation-3.6 '''AC-PC Transform'''] | ||
+ | *[https://www.slicer.org/wiki/Modules:Fiducials-Documentation-3.6 Fiducials] | ||
=== Keywords === | === Keywords === | ||
Line 27: | Line 24: | ||
===Input Data=== | ===Input Data=== | ||
− | * | + | *moving: T1 MPRAGE 1x1x1 mm voxel size |
===Registration Challenges=== | ===Registration Challenges=== |
Latest revision as of 18:05, 10 July 2017
Home < Projects:RegistrationLibrary:RegLib C15Back to ARRA main page
Back to Registration main page
Back to Registration Use-case Inventory
Contents
v3.6.1 Slicer Registration Library Case #15:
Brain MR Alignment along AC-PC line
Input
fixed image/target | moving image |
Modules
Keywords
MRI, brain, head, anterior commissure, posterior commissure, AC-PC Line, Talairach, fiducial alignment
Input Data
- moving: T1 MPRAGE 1x1x1 mm voxel size
Registration Challenges
- A dedicated module for AC-PC alignment is used.
- the only difficulty lies with accurate placement of the AC-PC fiducials. Depending on image resolution and contrast these can be difficult to find.
- midline fiducials should be easily obtainable from axial and coronal views. 3 midline fiducials suffice; more is recommended for a more robust solution.
Key Strategies
- this is a special case of fiducial-based alignment. Instead of aligning two sets of fiducial pairs, only one set of fiducials is aligned with a predefined orientation: The plane defined by the midline fiducials is aligned to be vertical in coronal/axial views, and the line defined by the AC-PC line is rotated to be horizontal in a sagittal view.
Registration Results