Difference between revisions of "2014 Summer Project Week:Proton pencil beam"

From NAMIC Wiki
Jump to: navigation, search
 
(6 intermediate revisions by 2 users not shown)
Line 2: Line 2:
 
<gallery>
 
<gallery>
 
Image:PW-MIT2014.png|[[2014_Summer_Project_Week#Projects|Projects List]]
 
Image:PW-MIT2014.png|[[2014_Summer_Project_Week#Projects|Projects List]]
Image:PW-Summer2014-PTPS-1.png|Proton beam in heterogenous media
+
Image:PW-Summer2014-PTPS-1.jpg|Proton beam in heterogenous media
 +
Image:photonss.jpg|Photon beam in water tank
 +
Image:beamss.jpg|External Beam Interface
 
</gallery>
 
</gallery>
  
 
==Key Investigators==
 
==Key Investigators==
 +
* Maxime Desplanques, MGH / Politecnico di Milano
 +
* Kevin Wang, PMH
 +
* Greg Sharp, MGH
  
 
==Project Description==
 
==Project Description==
Line 11: Line 16:
 
<div style="width: 27%; float: left; padding-right: 3%;">
 
<div style="width: 27%; float: left; padding-right: 3%;">
 
<h3>Objective</h3>
 
<h3>Objective</h3>
*
+
* The proton dose calculation module currently supports only a ray-trace algorithm
 +
* A pencil-beam algorithm that properly models lateral scattering has been developed
 
</div>
 
</div>
 
<div style="width: 27%; float: left; padding-right: 3%;">
 
<div style="width: 27%; float: left; padding-right: 3%;">
 
<h3>Approach, Plan</h3>
 
<h3>Approach, Plan</h3>
*
+
* Several stages of development are needed:
 +
** Add dose calculation algorithm selection widget to UI
 +
** Add beam modeling options to UI
 +
** Hook up calculation methods to new UI widgets
 +
** Adapt the Proton Pencil Beam Algorithm to a Photon Beam Algorithm
 
</div>
 
</div>
 
<div style="width: 27%; float: left; padding-right: 3%;">
 
<div style="width: 27%; float: left; padding-right: 3%;">
 
<h3>Progress</h3>
 
<h3>Progress</h3>
*
+
* The Proton Beam Algorithm was adapted to photons
 +
* The hierarchy for Proton/Photon Beam parameters/widgets in the interface was discussed
 +
* Some parameters/widgets from the interface were hooked to the algorithms. The other ones will be hooked in the next days
 
</div>
 
</div>
 
</div>
 
</div>

Latest revision as of 14:11, 27 June 2014

Home < 2014 Summer Project Week:Proton pencil beam

Key Investigators

  • Maxime Desplanques, MGH / Politecnico di Milano
  • Kevin Wang, PMH
  • Greg Sharp, MGH

Project Description

Objective

  • The proton dose calculation module currently supports only a ray-trace algorithm
  • A pencil-beam algorithm that properly models lateral scattering has been developed

Approach, Plan

  • Several stages of development are needed:
    • Add dose calculation algorithm selection widget to UI
    • Add beam modeling options to UI
    • Hook up calculation methods to new UI widgets
    • Adapt the Proton Pencil Beam Algorithm to a Photon Beam Algorithm

Progress

  • The Proton Beam Algorithm was adapted to photons
  • The hierarchy for Proton/Photon Beam parameters/widgets in the interface was discussed
  • Some parameters/widgets from the interface were hooked to the algorithms. The other ones will be hooked in the next days